Attachment_38_Amendment_No__0005_0005.pdf

PDF 1 MB Posted

Attached to
FKC Middle Reach Capacity Correction Project Phase Federal contract opportunity
Solicitation number
140R2020R0009
Issued by
Department of the Interior Bureau of Reclamation

About this file

This document is an engineering drawing attachment for the FKC Middle Reach Capacity Correction Project Phase 1 solicitation issued by the Department of the Interior Bureau of Reclamation under solicitation number 140R2020R0009. The attachment provides details for cathodic protection systems to be installed on various pipelines as part of the project, including test station locations and spacing, anode types and quantities required based on pipeline diameters and lengths. Pipelines referenced include Tipton Ditch Pipe, Poplar Ditch Pipe, SID S1 Pipe, SID S2 Pipe, DEID 24 E Pipe, DEID 24 W Pipe, KTWD 2 Pipe, DEID 24 E Pump Discharge Pipe, and KTWD 2 Discharge Pipe.

View the file

Other files for this federal contract opportunity

Other files attached to FKC Middle Reach Capacity Correction Project Phase, newest first.
File Type Posted
Attachment_8_Amendment__0006_0006.pdf PDF
Attachment_3_Amendment_0006_0006.pdf PDF
Attachment_44_Amendment_0005_0005.pdf PDF
Attachment_41_Amendment_0005_0005.pdf PDF
Attachment_40_Amendment_No_0005_0005.pdf PDF
Attachment_30_Amendment_No__0005_0005.pdf PDF
Attachment_27_Amendment_No__0005_0005.pdf PDF
Attachment_17_Amendment_No__0005_0005.pdf PDF
Attachment_15_Amendment_No__0005_0005.pdf PDF
Attachment_9_Amendment_No_0005_0005.pdf PDF
Attachment_12_Amendment_No__0005_0005.pdf PDF
Attachment_1_Amendment_No_0005_0005.pdf PDF
Attachment_29_Amendment_No_0004_0004.pdf PDF
Attachment_28_Amendment_No__0004_0004.pdf PDF
Attachment_23_Amendment_No__0004_0004.pdf PDF
Attachment_22_Amendment_No__0004_0004.pdf PDF
Attachment_20_Amendment_No__0004_0004.pdf PDF
Attachment_16_Amendment_No__0004_0004.pdf PDF
Attachment_13_Amendment_No__0004_0004.pdf PDF
Attachment_12_Amendment_No_0004_0004.pdf PDF
Attachment_6_Amendment_No_0004_0004.pdf PDF
Attachment_5_Amendment_No_0004_0004.pdf PDF
Attachment_25_Amendment_No__0004_0004.pdf PDF
Attachment_21_Amendment_No__0004_0004.pdf PDF
Attachment_19_Amendment_No__0004_0004.pdf PDF
Attachment_15_Amendment_No__0004_0004.pdf PDF
Attachment_7_Amendment_No_0004_0004.pdf PDF
Drawing_GC-15_Attachment_20_Amendment_No__0003_0003.pdf PDF
Drawing_G-13_Attachment_17__Amendment_No__0003_0003.pdf PDF
Drawing_C-506_Attachment_15_Amendment_No__0003_0003.pdf PDF
Drawing_C-215_Attachment_12_Amendment_No__0003_0003.pdf PDF
Drawing_C-214_Attachment_11_Amendment_No__0003_0003.pdf PDF
Drawing_C-204_Attachment_7_Amendment_No__0003_0003.pdf PDF
Drawing_GC-17_Attachment_21_Amendment_No__0003_0003.pdf PDF
Drawing_G-03_Attachment_18_Amendment_No__0003_0003.pdf PDF
Drawing_C-703_Attachment_16_Amendment_No__0003_0003.pdf PDF
Drawing_C-304_Attachment_14_Amendment_No__0003_0003.pdf PDF
Drawing_C-203_Attachment_6_Amendment_No__0003_0003.pdf PDF
Amendment_No__0003_for_Solicitation_140R2020R0009_0003.pdf PDF
Attachment_1_Amendment_No_0003_0003.pdf PDF
FKC_31_30_00-12_Att_7_Amendment_0002_0002.pdf PDF
FKC_01_14_00-12_Att_6__Amendment_0002_0002.pdf PDF
GC-10-REV-1_Att_5_Amendment_No__0002_0002.pdf PDF
Attachment_No__2_-_FKC_Pre-Proposal_Presentation_Sign_in_Sheet_0002.pdf PDF
Attachment 13 - Drawing Part 1 of 5.pdf PDF
Attachment 9 - Experience and Management.pdf PDF
Attachment 4 - Offeror Responsibility Information.pdf PDF
Attachment 2 - Subcontracting Plan.pdf PDF
Attachment 3 - Past Performance Questionnaire.pdf PDF
Solicitation 140R2020R0009.pdf PDF
Show all 50

FKC Middle Reach Capacity Correction Project Phase has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Project No.:

Scale:

Revision:

Drawing No.

Title Dsgn. Chkd. YYYY.MM.DDDwn.

Th e

C on tra ct or sh al l v er ify a nd b e re sp on sib le fo r a ll d im en sio ns

. D O

N O

T s ca le th e dr aw in g

- a ny e rro rs or o m iss io ns sh al l b e re po rte d to S ta nt ec w ith ou t d el ay

Th e

C op yr ig ht s t o al l d es ig ns a nd d ra w in gs a re th e pr op er ty o f S ta nt ec

. R ep ro du ct io n or u se fo r a ny p ur po se o th er th an th at a ut ho riz ed b y St an te c is fo rb id de n.

File Name: FKC_GC-13

ORIGINAL SHEET - ANSI D

c:

\u se rs\ rru ck er \d oc um en ts\ pr oj ec ts\ fri an t w at er a ut ho rit y\ dr aw in gs

\c ivi l\ w or kin g ca d\ fk c_ gc

-1

.0 6.

1:

:5

PM

Te l:

w w w .st an te c.

co m

St an te c

C S tre et

S ui te

Sa cr am en to , C

A

6.

4.

A

B

C

D

1 2 3 4 5

FR

IA

NT

-K

ER

N C

AN

AL

M

ID

DL

E

RE

AC

H

C

AP

AC

ITY

C

O

RR

EC

TIO

N

PR

O

JE

C T

PH

AS

E

Li nd sa y, C

A

YY

YY

.M

M .D

D Re vis io n By

Ap pd

Permit/Seal

Permit/Seal

YY

YY

.M M

.D D

Ac ce pt ed

: S co tt W ol fe rt

2021.02.05

184031016

.1 2.

Sheet: of 203

GC-13

CATHODIC

PROTECTION DETAILS

C. RIPPLER. RUCKERW. WEBER

AM

EN

DM

EN

T #

RR

M C

.06 .17

NOTE:

REINFORCING WIRE NOT SHOWN FOR CLARITY

1. FILE PIPE TO BARE METAL AND CLEAN

SURFACE.

2. STRIP INSULATION FROM WIRE AND ATTACH

SLEEVE.

3. HOLD MOLD FIRMLY WITH OPENING AWAY FROM

OPERATOR. IGNITE WITH FLINT GUN. REMOVE

SLAG FROM CONNECTION WITH CHIPPING

HAMMER.

4. COVER CONNECTION WITH EPOXY PUTTY OR

EXOTHERMIC WELD CAP OVER ALL EXPOSED

METAL. REPAIR ALL DAMAGE TO COATING AND

LINING IN ACCORDANCE WITH MFG

RECOMMENDATIONS.

TEST LEAD, BOND WIRE,

OR DRAIN CABLE

CEMENT MORTAR COATING

STEEL CYLINDER

EXOTHERMIC WELD

(TYP)

SEE DETAIL

CEMENT GROUT

EPOXY PUTTY

CHIP MORTAR AS

REQUIRED FOR

WELDING

COVER

MARKED WITH "ANODE"

CONCRETE TRAFFIC

VALVE BOX

FINAL GRADE

20" x 20" x 6"

CONCRETE COLLAR

TEST TERMINAL

BOARD

EPOXY PUTTY OR

EXOTHEMIC WELD

CAP

WIRE

PIPE/STRUCTURE

WIRE

DISC

WELD METAL

GRAPHITE MOLD

WIRE

SLEEVE

PIPE

#4 REBAR HOOP (TYP)

FLUSH-MOUNTED TRAFFIC BOX

TEST STATION DETAIL

SCALE: NTS

TEST LEAD/DRAIN CABLE CONNECTION DETAIL

CEMENT MORTAR COATED AND LINED STEEL PIPE

SCALE: NTS

EXOTHERMIC WELD DETAIL

SCALE: NTS

NOTES:

BOTTOM OF PIPE

TOP OF ANODE

FLUSH-MOUNTED

TEST STATION

SEE DETAILS

GRADE

EXOTHERMIC WELD

(TYP)

SEE DETAILS

ANODE (TYP)

40D3 HI POTENTIAL

MAGNESIUM

AMOUNT PER TABLE

ANODE PLACEMENT

SECTION

SCALE: NTS

AWG #10 HMWPE (BLACK)

LENGTH AS REQUIRED

AWG #10 HMWPE

(WHITE)

ANODE LOCATIONS

PIPELINE

DRAWING

REFERENCE

PIPELINE

DIAMETER

NUMBER OF

PIPELINES

TEST

STATIONS PER

PIPELINE

ANODES PER

TEST STATION

TOTAL

NUMBER OF

ANODES

TIPTON DITCH PIPE C-502 60''

2 2 4 16

POPLAR DITCH PIPE C-503 36''

1 2 3 6

SID S1 PIPE C-401 42''

2 1 2 4

SID S2 PIPE C-402 42''

2 1 2 4

DEID 24 E PIPE C-411 42''

1 2 4 8

DEID 24 W PIPE C-411 48''

2 2 6 24

KTWD 2 PIPE C-411 42''

1 2 5 10

DEID 24 E PUMP

DISCHARGE

C-412-2 42''

1 2 4 8

KTWD 2 DISCHARGE

PIPE

C-411-2 36''

1 2 3 6

TEST TERMINAL

BOARD DETAIL

SCALE: NTS

ANODE CABLE FOR

PIPELINE #10 BLACK

JUMPER CABLE #10 WHITE

PIPE LEAD #10 WHITE

CEMENT MORTAR

COATING

STEEL CYLINDER

5'-0"

(TYP)

DETAIL 5 NOTES

1. FOR INSTANCES WHERE MULTIPLE PIPELINES ARE INSTALLED

PARALLEL TO EACH OTHER THE ANODES SHALL BE INSTALLED AT

A MINIMUM 15' SPACING ON THE SIDE OF PIPE AWAY FROM THE

PARALLEL PIPELINES WHERE NO ANODE IS INSTALLED BETWEEN

THE PARALLEL PIPELINES.

Attachment 38 Amendment No. 0005

AutoCAD SHX Text C77436

AutoCAD SHX Text C66888

AutoCAD SHX Text

ANODE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

Sheets and Views
GC-13

File details come from the government source that posted it. Updated .