About this file
This attachment to an amendment provides details for abandoning eight groundwater monitoring wells as part of the FKC Middle Reach Capacity Correction Project Phase 1 solicited by the Bureau of Reclamation. The wells range from 30 to 12 inches in diameter and depths of 1,200 to 1,200 feet. Abandonment shall be per Tulare County standards and specification section 33 20 16 involving sealing the upper zone with neat cement and filling the lower zone with inorganic material. The existing well casing will be cut and disposed of a minimum dimension below grade.
View the file
Other files for this federal contract opportunity
Show all 50
FKC Middle Reach Capacity Correction Project Phase has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
B
CD-3
WELL ABANDONMENT
DETAIL
NTS
RIPPLE RUCKER WEBER
Project No.:
Scale:
Revision:
Drawing No.
Title Dsgn. Chkd. YYYY.MM.DDDwn.
Th e
C on tra ct or sh al l v er ify a nd b e re sp on sib le fo r a ll d im en sio ns
. D O
N O
T s ca le th e dr aw in g
- a ny e rro rs or o m iss io ns sh al l b e re po rte d to S ta nt ec w ith ou t d el ay
Th e
C op yr ig ht s t o al l d es ig ns a nd d ra w in gs a re th e pr op er ty o f S ta nt ec
. R ep ro du ct io n or u se fo r a ny p ur po se o th er th an th at a ut ho riz ed b y St an te c is fo rb id de n.
File Name: FKC_CD-03
ORIGINAL SHEET - ANSI D
c:
\p w w or kd ir\ d0
\f kc _c d-
.0 6.
:0 4:
P
M
Te l:
w w w .st an te c.
co m
St an te c
C S tre et
S ui te
Sa cr am en to , C
A
6.
4.
A
B
C
D
1 2 3 4 5
FR
IA
NT
-K
ER
N C
AN
AL
M
ID
DL
E
RE
AC
H
C
AP
AC
ITY
C
O
RR
EC
TIO
N
PR
O
JE
C T
PH
AS
E
Li nd sa y, C
A
YY
YY
.M
M .D
D Re vis io n By
Ap pd
Permit/Seal
Permit/Seal
YY
YY
.M M
.D D
Ac ce pt ed
: S co tt W ol fe rt
2021.02.05
184031016
.1 2.
Sheet: of 203
GENERAL NOTES
1. WELL DEPTHS AND DIMENSIONS SHOWN ARE APPROXIMATE
BASED ON BEST AVAILABLE INFORMATION. THE CONTRACTOR
SHALL FIELD VERIFY THE CASING DIMENSION AND WELL DEPTH
PRIOR TO ABANDONMENT.
2. WELLS SHALL BE ABANDONED PER TULARE COUNTY STANDARDS,
REFER TO SPECIFICATION 33 20 16.
WELL NO. STATION "A" "B" "C"
(FT) (FT) (IN)
W-1 5328+86 5 1,200 30 W-2 5348+04 5 1,200 30 W-3 5596+81 5 1,200 30 W-4 5861+28 5 1,200 30 W-5 5901+16 5 1,200 30 W-6 5959+74 5 1,200 30 W-7 5359+00 5 1,200 12
W-8 5786+75 5 1,200 30
A
B
C
D
E
"C"
A
AM
EN
DM
EN
T #
RR
M C
.0 6.
AM
EN
DM
EN
T #
RR
M
C
.0
6.
EXISTING GROUND
SHEET KEYNOTES
A. FINISH CEMENT WITH ROUND "MUSHROOM" CAP.
B. BACKFILL WITH NATIVE MATERIAL (95% COMPACTION).
C. UPPER ZONE SEALING MATERIAL (NEAT CEMENT PER SECTION
33-20-16).
D. LOWER ZONE FILL MATERIAL (INORGANIC FILL PER SECTION
33-20-16).
E. CUT EXISTING WELL CASING AT A MINIMUM DIMENSION "A" BELOW
EXISTING GRADE. DISPOSE OF WELL CASING PER SPECIFICATIONS.
Attachment 32 Amendment No. 0005