This submittal list outlines product and service requirements for the rehabilitation of the First Bank building in Independence National Historical Park in Philadelphia, Pennsylvania. The project involves interior and exterior restoration work including masonry, plaster, woodwork, windows, mechanical and electrical systems. The submittal list specifies over 200 required submittals from the contractor organized by specification section, including product data, shop drawings, samples, test reports, warranties and mockups. It also identifies the required timing of submittals and actions required for approval. The related federal contract opportunity is solicitation number 140P2023R0002 for the rehabilitation work with the National Park Service as the contracting agency.

View the file

Other files

File Type Posted
Sol_140P2023R0002_Amd_0008.pdf PDF
INDE_245589_Final_questions_and_answers_0008.xlsx XLSX spreadsheet
B08_Attach_125_REV_A7_12-_3RD_FLR_ADDN_FLOORING_PATTERN_0007.pdf PDF
B08_Attach_139_REV_1st_Bank_01_27_00_1A_ContractPriceSchedule_0007.pdf PDF
B08_Attach_117_REV_A3_3-TRANS_SECTS_THRU_ADDN_0007.pdf PDF
B08_Attach_141_REV_1st_Bank_01_22_00B_Unit_Prices_0007.pdf PDF
B08_Attach_148_REV_A8_15-_DECOR_PLASTER___TRENCH_DTLS_0007.pdf PDF
B08_Attach_126_REV_A8_1-FIRST_FLR_INT_ELEVS_0007.pdf PDF
B08_Attach_93_REV_1st_Bank_028214_Asbestos_Remediation_0007.pdf PDF
B08_Attach_104_REV_1st_Bank_142400A_Hydraulic_Elevators_0007.pdf PDF
B08_Attach_94_REV_1st_Bank_042000_Unit_Masonry_0007.pdf PDF
B08_Attach_158_REV__096623_Resin_Matrix_Terrazzo_Flooring_0007.pdf PDF
B08_Attach_115_REV_A2_2-WEST_ELEV_0007.pdf PDF
B08_Attach_133_REV_A9_6-EX_RAILING_MODIFICATIONS_0007.pdf PDF
B08_Attach_157_REV_1st_Bank_096519_Vinyl_Tile_0007.pdf PDF
B08_Attach_90_REV_C1_0_EXIST_COND___DEMO_OVERALL_PLAN_0007.pdf PDF
B08_Attach_143_REV_A2_3-SOUTH_ELEV_0007.pdf PDF
B08_Attach_136_REV_1st_Bank_01_40_00_Quality_Requirements_0007.pdf PDF
B08_Attach_113_REV_A2_0C-PORTICO_ELEV_EXT_REHAB_0007.pdf PDF
B08_Attach_161_REV_1st_Bank_142400B_Hydraulic_Elevators_0007.pdf PDF
B08_Attach_155_REV_084123_FireRated_Glass_and_Framing_Systems_0007.pdf PDF
B08_Attach_98_REV_1st_Bank_057313_Glazed_Decorative_Metal_Railings_0007.pdf PDF
B08_Attach_111_REV_A1_9A-ATTIC___3RD_FLR_SLAB_EDGE_PLN_ADDN_0007.pdf PDF
B08_Attach_160_REV_1st_Bank_122413A_Roller_Window_Shades_0007.pdf PDF
B08_Attach_119_REV_A6_7-_DOOR___FRAME_DETAILS_0007.pdf PDF
B08_Attach_156_REV_1st_Bank_088000_Glass_and_Glazing_0007.pdf PDF
B08_Attach_116_REV_A2_3-SOUTH_ELEV_0007.pdf PDF
B08_Attach_135_G1_0_SHEET_INDEX_0007.pdf PDF
B08_Attach_142_REV_01_27_00_DefinitionofContracLineItems_0007.pdf PDF
B08_Attach_109_REV_A1_8A-2ND_FLR_SLAB_EDGE_PLN_ADDN_0007.pdf PDF
B08_Attach_129_REV_A8_4-2ND_FLR_INT_ELEVS_0007.pdf PDF
B08_Attach_130_REV_A8_6-_3RD_FLR_INT_ELEVS_0007.pdf PDF
B08_Attach_138_REV_1st_Bank_017700_1_Closeout_OM_Requirements_0007.pdf PDF
B08_Attach_110_REV_A1_9-3RD_FLR_PLN_ADDN_0007.pdf PDF
B08_Attach_145_REV_A6_13-WDO_SCHED___DTLS_0007.pdf PDF
B08_Attach_106_REV_A1_5-BSMT_FLR_PLN_ADDN_0007.pdf PDF
B08_Attach_101_REV_1st_Bank_084413_Glazed_Aluminum_Curtain_Walls_0007.pdf PDF
B08_Attach_149_REV_A9_8_-_STAIR_RAILING___ADDITION_0007.pdf PDF
B08_Attach_92_REV_1st_Bank_015000_Temporary_Facilities_And_Controls_0007.pdf PDF
B08_Attach_146_REV_A8_0-FINISH_SCHED___DTLS_0007.pdf PDF
B08_Attach_123_REV_A7_10-1ST_FLR_ADDN_FLOORING_PATTERN_0007.pdf PDF
B08_Attach_150_REV_C3_0_Utility_Plan_0007.pdf PDF
B08_Attach_107_REV_A1_6-1ST_FLR_PLN_ADDN_0007.pdf PDF
B08_Attach_124_REV_A7_11-_2ND_FLR_ADDN_FLOORING_PATTERN_0007.pdf PDF
B08_Attach_137_REV_1st_Bank01_27_00_1AContractPriceSchedule_0007.xlsx XLSX spreadsheet
B08_Attach_105_REV_A1_4-ROOF_PLN_0007.pdf PDF
B08_Attach_100_REV_1st_Bank_076200_Flashing_and_Sheet_Metal_0007.pdf PDF
B08_Attach_151_REV_G0_0_COVER_0007.pdf PDF
B08_Attach_114_REV_A2_1-NORTH_ELEV_0007.pdf PDF
B08_Attach_121_REV_A7_1_1ST_FLR_RCP_0007.pdf PDF
Show 40 more

Latest 50 of 185 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SUBMITTAL LIST

INDE-391-177832 / PMIS 245589

Project Title: First Bank of the United States

SUBMITTAL REQUIREMENTS

(Indicate with X)

INFORMATIONAL ACTION

S P

E C

IF

IC

A T

IO

N

S E

C T

IO

N

P A

R A

G R

A P

H N

U M

B E

R

DESCRIPTION

C E

R T

IF

IC

A T

IO

N

S O

R

LA

B

O R

A T

O R

Y T

E S

T S

R E

P O

R T

S O

R C

A

LC

U

LA

T

IO

N S

O R

P

LA

N

M A

N U

F A

C T

U R

E R

D A

T A

A N

D I

N S

T R

U C

T

IO

N S

O T

H E

R

S A

M P

LE

S

S H

O P

D R

A W

IN

G

S

M A

N U

F A

C T

U R

E R

D A

T A

A N

D I

N S

T R

U C

T

IO

N S

O T

H E

R

13100 1.4.D Letter designating Project Superintendent X

13100 1.4.D List of Subcontractors X

13100 1.4.D Subcontractors' Certification of Labor Compliance X

13100 1.4.D Certificates of Insurance - Contractor & Subcontractors X

13100 1.4.D List of Required Permits X

13218 1.3.A Construction Schedule X

13218 1.3.B Schedule of Values X

13233 1.2.A Construction Progress Photographs X

13513 1.3.A Excavation Plan for Archeological Protection X

13513 1.3.A Work Schedule for Archeologically Sensitive Areas X

13523 1.3.A Accident Prevention Plan X

13591 1.3.A Historic Preservation Treatment Plan X

14000 1.4.A Quality Control Plan X

14000 1.4.B Qualifications of Testing Agency X

14000 1.4.C Contractor Quality Control Daily Reports X

14000 1.5.K Integrated Exterior Mock-up X

14000 1.5.L Plaster Removal/Reinstallation Mock-Up X

14000 1.5.M Masonry Conservation Cleaning Mock-Up X

15000 1.4.A Scaffolding and Pedestrian Protection Plan X

15000 1.4.B Temporary Fire Detection Plan X

15719 1.4.A Indoor Air Quality Plan X

15723 1.3.A Under-An-Acre Pollution Prevention Plan X

16700 1.3.A Affirmative Procurement Reporting Form X

16700 1.3.A Environmental Data for Selected Products X

16700 1.3.A Chain of Custody Documentation for Wood Products X

17329 1.2.A Cutting and Patching Plan X

17340 1.2.A Surveyor's Certification X

17419 1.4.A Waste Management Plan X

17419 1.4.B Progress Documentation - Waste Disposal X

17419 1.4.C Records of Donations X

17419 1.4.D Records of Material Sales X

17419 1.4.E Recycling & Processing facility records X

Submittal List National Park Service (NPS) - Denver Service Center (DSC) | 1-27-21

Submittal List with Review Estimate Template | National Park Service (NPS) - Denver Service Center (DSC) page 1 of 22

Project Title: First Bank of the United States

SUBMITTAL REQUIREMENTS

(Indicate with X)

INFORMATIONAL ACTION

S P

E C

IF

IC

A T

IO

N

S E

C T

IO

N

P A

R A

G R

A P

H N

U M

B E

R

DESCRIPTION

C E

R T

IF

IC

A T

IO

N

S

O R

A T

O R

Y T

E S

T S

R E

P O

R T

S O

R C

A

LC

U

LA

T

IO

N S

O R

P

LA

N

M A

N U

F A

C T

U R

E R

D A

T A

A N

D I

N S

T R

U C

T

IO

N S

O T

H E

R

S A

M P

LE

S

S H

O P

D R

A W

IN

G

S

M A

N U

F A

C T

U R

E R

D A

T A

A N

D I

N S

T R

U C

T

IO

N S

O T

H E

R

17419 1.4.F Landfill & Incinerator records X

17419 1.4.G Qualifications - Waste Management Coordinator X

17419 1.4.H Progress Reports for Payment X

17823 1.2.A Operation and Maintenance Manuals X

17900 1.3.A Demonstration and Training Program (digital copy) X

19114 1.6.D Commissioning Plan X

19114 1.6.C Qualifications - Contractor's commissioning representative X

19114 1.6.H List of Testing Equipment X

19114 1.6.G Performance Test Forms X

19114 1.6.B Certificates of Readiness X

19114 1.6.A Testing and Commissioning Schedule X

24119 1.4.A Engineering Survey X

24119 1.4.B Proposed protection measures X

24119 1.4.C Schedule of selective demolition activities X

24119 1.4.D Predemolition video or photographs X

24296 1.5.A Qualifications - Historic dismantling specialist X

24296 1.5.B Preconstruction documentation of conditions specific to dismantling X

24296 1.5.C Removal and Dismantling Historic Treatment Plan X

24296 1.5.D List of Items to be Salvaged X

24296 1.5.E Final Inventory of Salvaged items X

24296 1.5.F Basement Key Plan identifying historic hardware to be removed X

28200 1.4.A Asbestos Remediation Plan X

30130 1.4.A Product Data - Concrete Restoration Materials and Products X

30130 1.4.A Concrete Field Testing Reports X

30130 1.5.B Mock-Up - Concrete Spall Patching X

30130 1.5.B Mock-Up - Concrete Floor Cleaning X

33000 1.5.A Product Data - Concrete/reinforcing materials & products X

33000 1.5B Concrete Design Mixes X

33000 1.5.C Shop Drawings: Concrete reinforcing X

33000 1.5.D Concrete Installation Schedule X

33000 1.5.E Concrete Construction Joint Layout X

33000 1.5.A Qualification Data - Concrete mfctr, installer, test agency X

33000 1.5.B Qualification Statement - Concrete testing agency X

33000 1.5.C Welding Certificates X

33000 1.5.D Concrete Material Certificates X

Submittal List with Review Estimate Template | National Park Service (NPS) - Denver Service Center (DSC) page 2 of 22

Project Title: First Bank of the United States

SUBMITTAL REQUIREMENTS

(Indicate with X)

INFORMATIONAL ACTION

S P

E C

IF

IC

A T

IO

N

S E

C T

IO

N

P A

R A

G R

A P

H N

U M

B E

R

DESCRIPTION

C E

R T

IF

IC

A T

IO

N

S

O R

A T

O R

Y T

E S

T S

R E

P O

R T

S O

R C

A

LC

U

LA

T

IO

N S

O R

P

LA

N

M A

N U

F A

C T

U R

E R

D A

T A

A N

D I

N S

T R

U C

T

IO

N S

O T

H E

R

S A

M P

LE

S

S H

O P

D R

A W

IN

G

S

M A

N U

F A

C T

U R

E R

D A

T A

A N

D I

N S

T R

U C

T

IO

N S

O T

H E

R

33000 1.5.E Concrete Material Test Reports X

33000 1.5.F Concrete Floor flatness/levelness measurements X

33000 1.5.G Research Reports -Concrete admixtures & vapor retarder X

33000 1.5.H Preconstruction Test Reports - Concrete Mix Designs X

33000 1.5.I Concrete Field Testing Reports X

40310 1.4.A Product Data - Masonry Cleaning Materials X

40310 1.5.C Mock-Up - Marble Floor Cleaning X

40310 1.5.C Mock-Up - Cleaning of Fieldstone Masonry Walls X

40310 1.5.C Mock-Up - Cleaning of Brick Masonry Vaults X

40310 1.5.C Mock-Up - Cleaning of Marble Water Table X

40311 1.4.A Product Data - Conservation Cleaning Materials X

40311 1.5.C Mock-Up Panel: Pilaster Cleaning X

40311 1.5.C Mock-Up Panel: Column Shaft Cleaning X

40322 1.4.A.1Product Data -- Mortar materials X

40322 1.4.A.2Product Data - New brick X

40322 1.4.B.1Samples - Cured samples of pointing mortar X

40322 1.4.B.2Samples - New brick X

40322 1.5.A Mock-up panel - Brick patching X

40322 1.5.B Mock-up panel - Brick replacement X

40323 1.4.A Product Data -- Mortar materials X

40323 1.4.B Samples -- Cured samples of pointing mortar X

40323 1.5.B Mock-up panel - Brick masonry joint raking X

40323 1.5.B Mock-up panel - Brick masonry joint pointing X

40342 1.4.A Product Data - Mortar materials X

40342 1.4.B Samples -- New replacement fieldstone X

40342 1.5.B Mock-up panel - Fieldstone masonry infill X

40343 1.4.A Product data - Mortar materials X

40343 1.4.B Samples -- Cured samples of limestone pointing mortar X

40343 1.4.B Samples - Cured samples of marble pointing mortar X

40343 1.5.B Mock-up panel - Limestone masonry raking & pointing X

40343 1.5.B Mock-up panel - Marble masonry raking & pointing X

40344 1.4.A Product data - Stone repair materials X

40344 1.4.B Shop drawings - New stone fabrications X

40344 1.4.C Samples - Stone repair fasteners/anchors X

40344 1.4.C Samples - New stone dutchman material X

Submittal List with Review Estimate Template | National Park Service (NPS) - Denver Service Center (DSC) page 3 of 22

Project Title: First Bank of the United States

SUBMITTAL REQUIREMENTS

(Indicate with X)

INFORMATIONAL ACTION

S P

E C

IF

IC

A T

IO

N

S E

C T

IO

N

P A

R A

G R

A P

H N

U M

B E

R

DESCRIPTION

C E

R T

IF

IC

A T

IO

N

S

O R

A T

O R

Y T

E S

T S

R E

P O

R T

S O

R C

A

LC

U

LA

T

IO

N S

O R

P

LA

N

M A

N U

F A

C T

U R

E R

D A

T A

A N

D I

N S

T R

U C

T

IO

N S

O T

H E

R

S A

M P

LE

S

S H

O P

D R

A W

IN

G

S

M A

N U

F A

C T

U R

E R

D A

T A

A N

D I

N S

T R

U C

T

IO

N S

O T

H E

R

40344 1.4.C Samples - Cured stone patching mortar X

40344 1.5.C Mock-up panel - Injection crack repair X

40344 1.5.C Mock-up panel - Micro-pin repair X

40344 1.5.C Mock-up panel - Window head dutchman installation X

40344 1.5.C Mock-up panel - Mortar patching - Limestone X

40344 1.5.C Mock-up panel - Mortar patching - Marble X

40344 1.5.C Mock-up panel - Slurry repairs X

42000 1.3.A Product data -- Mortar materials X

42000 1.3.A Product data -- New brick X

42000 1.3.B Samples -- Cured mortar samples X

42000 1.3.B Samples - New brick X

42000 1.4.A Material certificates -- Mortar materials X

42000 1.4.A Material certificates -- New brick X

42000 1.4.B Mix design & Test Reports - Mortar

42000 1.4.B Mix design & Test Reports - Grout

42200 1.3.A Product data - CMUs, reinforcing, accessories X

42200 1.3.B Shop drawings - CMU reinforcement X

42200 1.3.C Samples - CMU for exposed applications X

42200 1.4.A Material cerificates X

42200 1.4.B Mix designs - Mortar and grout X

42200 3.8 Field quality control reports X

47200 1.3.A Product data -- Cast stone X

47200 1.3.B Delegated Design Submittal X

47200 1.3.C Shop Drawings - Cast Sonte X

47200 1.3.D Samples - Cast stone X

47200 1.4.A Qualification data - Cast stone fabricator

50383 1.4.A Product data -- Iron restoration materials X

50383 1.4.B Restoration procedures - Historic iron and steel X

50383 1.4.C Pre-restoration documentation X

50383 1.5.C Mock-up panel - Embedded iron component X

50383 1.5.C Mock-Up Panel - HVAC grille X

51200 1.4.A Product data - Structural steel material X

51200 1.4.A Product data - Connectors, bolt and washer assemblies X

51200 1.4.A Product data - Anchor rods, threaded rods X

51200 1.4.A Product data - Slide bearings X

Submittal List with Review Estimate Template | National Park Service (NPS) - Denver Service Center (DSC) page 4 of 22

Project Title: First Bank of the United States

SUBMITTAL REQUIREMENTS

(Indicate with X)

INFORMATIONAL ACTION

S P

E C

IF

IC

A T

IO

N

S E

C T

IO

N

P A

R A

G R

A P

H N

U M

B E

R

DESCRIPTION

C E

R T

IF

IC

A T

IO

N

S

O R

A T

O R

Y T

E S

T S

R E

P O

R T

S O

R C

A

LC

U

LA

T

IO

N S

O R

P

LA

N

M A

N U

F A

C T

U R

E R

D A

T A

A N

D I

N S

T R

U C

T

IO

N S

O T

H E

R

S A

M P

LE

S

S H

O P

D R

A W

IN

G

S

M A

N U

F A

C T

U R

E R

D A

T A

A N

D I

N S

T R

U C

T

IO

N S

O T

H E

R

51200 1.4.A Product data - Etching cleaner, primers and paints X

51200 1.4.A Product data - Non-shrink grout X

51200 1.4.B Shop drawings - Structural steel X

51200 1.4.C Delegated Design Submittal - Structural steel X

51200 1.5.A Qualification data - Steel fabricator and installer X

51200 1.5.B Welding certificates X

51200 1.5.C Compatibility certificate - Steel primer X

51200 1.5.D Mill test reports - Structural steel X

51200 1.5.E Product test reports - fasteners, connectors, bolts, etc X

51200 1.5.F Survey of existing conditions X

51200 1.5.G Source quality control reports - Structural steel X

51200 1.5.H Field quality control reports - Structural steel X

53100 1.2.A Product data - Steel decking and composite floor decking X

53100 1.2.B Shop drawings - Decking X

53100 1.3.A Wedling certificates - Decking X

53100 1.3.A Product certificates - Steel decking X

53100 1.3.B Product test reports - Powder actuated fasteners X

53100 1.3.B Research reports - Steel decking X

53100 1.3.C Field quality control reports - Decking X

53100 1.3.D Qualifications statements - Welders X

54000 1.3.A Product data - Cold-formed steel framing materials X

54000 1.3.A Product data - Load-bearing wall framing materials X

54000 1.3.A Product data - Non-load-bearing wall framing materials X

54000 1.3.A Product data - Vertical deflection and drift clips X

54000 1.3.A Product data - Single and double deflection tracks X

54000 1.3.A Product data - Roof rafter framing X

54000 1.3.A Product data - Ceiling joist & soffit framing, ceiling joist hangers X

54000 1.3.A Product data - Furring channels X

54000 1.3.A Product data - Post-installed anchors X

54000 1.3.A Product data - Sill sealer gasket X

54000 1.3.A Product data - Powder-actuated fasteners X

54000 1.3.B Shop drawings - Cold-formed metal framing X

54000 1.3.C Delegated Design Submittal - Cold-formed steel framing X

54000 1.4.A Qualifications - Testing agency X

54000 1.4.B Welding certificates X

Submittal List with Review Estimate Template | National Park Service (NPS) - Denver Service Center (DSC) page 5 of 22

Project Title: First Bank of the United States

SUBMITTAL REQUIREMENTS

(Indicate with X)

INFORMATIONAL ACTION

S P

E C

IF

IC

A T

IO

N

S E

C T

IO

N

P A

R A

G R

A P

H N

U M

B E

R

DESCRIPTION

C E

R T

IF

IC

A T

IO

N

S

O R

A T

O R

Y T

E S

T S

R E

P O

R T

S O

R C

A

LC

U

LA

T

IO

N S

O R

P

LA

N

M A

N U

F A

C T

U R

E R

D A

T A

A N

D I

N S

T R

U C

T

IO

N S

O T

H E

R

S A

M P

LE

S

S H

O P

D R

A W

IN

G

S

M A

N U

F A

C T

U R

E R

D A

T A

A N

D I

N S

T R

U C

T

IO

N S

O T

H E

R

54000 1.4.C Product certificates - Studs and tracks X

54000 1.4.D Product test reports - Steel sheet X

54000 1.4.D Product test reports - Expansion & Powder-actuated anchors X

54000 1.4.D Product test reports - Mechanical fasteners X

54000 1.4.D Product test reports - Vertical deflection & Drift Clips X

54000 1.4.D Product test reports - Ceiling joist hangers X

54000 1.4.D Product test reports - Miscellaneous structural clips X

54000 1.4.E Research reports - Expansion & Powder-actuated anchors X

55000 1.4.A Product data - Fasteners X

55000 1.4.A Product data - Shop primers X

55000 1.4.A Product data - Non-shrink grout X

55000 1.4.A Product data - Manufactured metal ladders X

55000 1.4.A Product data - Ladder safety cages X

55000 1.4.A Product data - Metal ships' ladders X

55000 1.4.B Shop drawings - Steel framing/supports for toilet partitions X

55000 1.4.B Shop drawings - Steel framing/supports for countertops X

55000 1.4.B Shop drawings - Steel framing/supports for equipment X

55000 1.4.B Shop drawings - Steel framing/supports for MEP equipment X

55000 1.4.B Shop drawings - Misc steel framing/supports X

55000 1.4.B Shop drawings - Elevator machine beams, hoist beams X

55000 1.4.B Shop drawings - Steel shapes for elevator door sills X

55000 1.4.B Shop drawings - Shelf angles X

55000 1.4.B Shop drawings - Slotted channel framing X

55000 1.4.B Shop drawings - Metal ladders X

55000 1.4.B Shop drawings - Ladder safety cages X

55000 1.4.B Shop drawings - Metal ships' ladders X

55000 1.4.B Shop drawings - Metal floor plates and supports X

55000 1.4.B Shop drawings - Elevator summ pit covers X

55000 1.4.B Shop drawings - Loose bearing and leveling plates X

55000 1.4.C Delegated design submittal - Metal ladders & Ships' ladders

55000 1.5.A Qualifications - Professional Engineer for deisgn submittal X

55000 1.5.B Mill certificates - Steel products X

55000 1.5.C Welding certificates X

55000 1.5.D Compatibility certificates - Shop primer X

55000 1.5.E Research reports - Post-installed anchors X

Submittal List with Review Estimate Template | National Park Service (NPS) - Denver Service Center (DSC) page 6 of 22

Project Title: First Bank of the United States

SUBMITTAL REQUIREMENTS

(Indicate with X)

INFORMATIONAL ACTION

S P

E C

IF

IC

A T

IO

N

S E

C T

IO

N

P A

R A

G R

A P

H N

U M

B E

R

DESCRIPTION

C E

R T

IF

IC

A T

IO

N

S

O R

A T

O R

Y T

E S

T S

R E

P O

R T

S O

R C

A

LC

U

LA

T

IO

N S

O R

P

LA

N

M A

N U

F A

C T

U R

E R

D A

T A

A N

D I

N S

T R

U C

T

IO

N S

O T

H E

R

S A

M P

LE

S

S H

O P

D R

A W

IN

G

S

M A

N U

F A

C T

U R

E R

D A

T A

A N

D I

N S

T R

U C

T

IO

N S

O T

H E

R

55113 1.3.A Product data -- Metal pan stairs X

55113 1.3.B Shop drawings - Metal pan stairs X

55113 1.3.C Delegated design submittal -- Metal pan stairs X

55113 1.3.D Certificate of compliance - Metal pan stairs X

57300 1.3.A Shop drawings - New decorative metal railings X

57300 1.3.B Product data -- Railing anchors X

57300 1.3.C Delegated design submission - New decorative metal railings X

57313 1.4.A Shop drawings - Glazed decorative metal railings X

57313 1.4.B Product data -- Glazed decorative metal railings X

57313 1.4.C Delegated design submittal - Glazed decorative metal railings X

60110 1.4.A Product data -- Wood restoration materials X

60110 1.4.B Grade stamps - Replacement lumber X

60110 1.4.C Shop drawings - Replacement moldings X

60110 1.4.D Samples -- Replacement moldings X

61000 1.3.A Product data -- Wood and pressure-treated wood products X

61000 1.3.A Product data -- Rough carpentry hardware X

61600 1.3.A Product data -- Fasteners and hardware X

61600 1.3.A Product data -- Gypsum sheathing X

61600 1.3.A Product data -- Cement board X

61600 1.3.A Product data - Plywood sheathings X

64013 1.3.A Product data - Fire retardant wood treatment X

64013 1.3.A Product data - Plastic fabrications X

64013 1.3.B Shop drawings - Cornice profiles X

64013 1.3.B Shop drawings -- Exterior lamp posts X

64013 1.3.C Samples - Cornice profiles X

64023 1.3.A Shop drawings -- Standing and running trim X

64023 1.3.A Shop drawings -- Radiator covers X

64023 1.3.A Shop drawings -- Reception desk X

64023 1.3.B Product data - Flexible wood trim X

64023 1.3.B Product data -- Countertop materials X

64023 1.3.B Product data -- Furniture hardware X

64023 1.3.C Samples -- Standing and running trim X

64023 1.3.C Samples -- Solid-surface countertop X

64023 1.3.C Samples -- Veneer plywood for custom furniture X

68200 1.3.A Product data - Fiberglass composite balustrade X

Submittal List with Review Estimate Template | National Park Service (NPS) - Denver Service Center (DSC) page 7 of 22

Project Title: First Bank of the United States

SUBMITTAL REQUIREMENTS

(Indicate with X)

INFORMATIONAL ACTION

S P

E C

IF

IC

A T

IO

N

S E

C T

IO

N

P A

R A

G R

A P

H N

U M

B E

R

DESCRIPTION

C E

R T

IF

IC

A T

IO

N

S

O R

A T

O R

Y T

E S

T S

R E

P O

R T

S O

R C

A

LC

U

LA

T

IO

N S

O R

P

LA

N

M A

N U

F A

C T

U R

E R

D A

T A

A N

D I

N S

T R

U C

T

IO

N S

O T

H E

R

S A

M P

LE

S

S H

O P

D R

A W

IN

G

S

M A

N U

F A

C T

U R

E R

D A

T A

A N

D I

N S

T R

U C

T

IO

N S

O T

H E

R

68200 1.3.B Delegated design submittal - Fiberglass composite balustrade X

68200 1.3.C Shop drawings - Fiberglass composite balustrade X

68200 1.4.D Finish Samples - Fiberglass composite balustrade X

68200 1.4.E Fabrication Samples-Custom balustrade components X

68200 1.4.F Statement of qualifications - Fiberglass fabricator & installer X

68200 1.4.G Sample warranty - Fiberglass composite X

68200 1.5.C Mock-up panel - Fiberglass composite balustrade X

71000 1.3.A Product data -- Cemenitious parging X

71000 1.3.A Product data -- Fluid-applied and sheet waterproofing X

71000 1.3.A Product data -- Drainage board X

72100 1.3.A Product data -- Board insulation X

72100 1.3.A Product data -- Batt insulation X

72100 1.3.B Test reports -- Board insulation X

72100 1.3.B Test reports -- Batt insulation X

72726 1.3.A Product data -- Weather barriers X

72726 1.3.A Product data -- Drainage mat X

75323 1.4.A Shop drawings -- EPDM roofing X

75323 1.4.B Product data - EPDM roofing and accessories X

75323 1.4.B Product data -- Roof insulation X

75323 1.4.B Product data -- Substrate board X

75323 1.4.C Material Certificates - EPDM roofing X

76100 1.3.A Shop drawings -- Sheet metal roofing X

76100 1.3.B Product data -- Shet metal roofing and accessory materials X

76100 1.3.C Samples -- Roofing material and fasteners X

76100 1.3.D Workmanship samples - Sheet metal roofing X

76200 1.3.A Shop drawings -- Flashing X

76200 1.3.B Product data -- Flashing and accessories X

76200 1.3.B Product data -- Downspouts and drainage specialties X

76200 1.3.C Samples -- Sheet metal flashing material X

77200 1.3.A Shop drawings -- Roof hatch X

77200 1.3.A Shop drawings -- Roof access ladder X

77200 1.3.B Product data -- Roof hatch X

77200 1.3.B Product data -- Roof access ladder X

77200 1.3.B Product data -- Ladder safety system X

78100 1.3.A Product data -- Spray-applied fireproofing X

Submittal List with Review Estimate Template | National Park Service (NPS) - Denver Service Center (DSC) page 8 of 22

Project Title: First Bank of the United States

SUBMITTAL REQUIREMENTS

(Indicate with X)

INFORMATIONAL ACTION

S P

E C

IF

IC

A T

IO

N

S E

C T

IO

N

P A

R A

G R

A P

H N

U M

B E

R

DESCRIPTION

C E

R T

IF

IC

A T

IO

N

S

O R

A T

O R

Y T

E S

T S

R E

P O

R T

S O

R C

A

LC

U

LA

T

IO

N S

O R

P

LA

N

M A

N U

F A

C T

U R

E R

D A

T A

A N

D I

N S

T R

U C

T

IO

N S

O T

H E

R

S A

M P

LE

S

S H

O P

D R

A W

IN

G

S

M A

N U

F A

C T

U R

E R

D A

T A

A N

D I

N S

T R

U C

T

IO

N S

O T

H E

R

78100 1.3.B Fire Resistance Design - Spray-applied fireproofing X

78100 1.4.A Maintenance information - Spray-applied fireproofing X

78100 1.4.B Field Quality Control Reports - Spray-applied fireproofing X

79100 1.3.A Product data - Precompressed joint seals X

79100 1.3.A Shop Drawings - Precompressed joint seals X

79100 1.3.A Samples - Precompressed joint seals X

79100 1.3.B Certification - Precompressed joint seals X

79200 1.4.A /*.Product data - Joint sealants, including warranties X

79200 1.4.B Joint Design/Shop Drawing - Curtain wall sealants X

79200 1.4.C Samples - Joint sealant color palette(s) for color selection X

79200 1.4.D Samples - Bead samples of selected sealant colors X

79200 1.4.E Schedule - Joint sealants X

79513 1.4.A Shop drawings - Expansion joint covers X

79513 1.4.B Product data - Expansion joint covers X

79513 1.4.C Expansion joint cover color palette for color selection X

81113 1.4.A Product data - Hollow metal doors and frames X

81113 1.4.B Shop drawings - Hollow metal doors and frames X

81433 1.3.A Shop drawings - Stile and rail and flush wood doors X

81433 1.3.B Product data - Stile and rail and flush wood doors X

81433 1.3.C Door Schedule - Stile and rail and flush wood doors X

84123 1.5.A Product data - Fire-rated glass and framing systems X

84123 1.5.B Shop drawings - Fire-rated glass and framing systems X

84123 1.5.C Structural calculations - Fire-rated glass and framing systems

84123 1.5.D Sample - Frame section - Fire-rated glass and framing systems X

84123 1.5.D Sample - Finish - Fire-rated glass and framing systems X

84123 1.5.E Glazing schedule - Fire-rated glass and framing systems X

84123 1.5.F Warranty - Fire-rated glass and framing systems X

84123 1.5.G Certification of Compliance - Fire-rated glass X

84413 1.3.A Product data - Glazed aluminum curtain wall X

84413 1.3.B Shop drawings - Glazed aluminum curtain wall X

84413 1.3.C Samples - Finish - Glazed aluminum curtain wall X

84413 1.3.D Installer qualifications - Glazed aluminum curtain wall X

84413 1.3.D Test reports - Glazed aluminum curtain wall X

84413 1.4.B Mock-up panel - Glazed aluminum curtain wall X

85113 1.4.B Product data - Aluminum windows X

Submittal List with Review Estimate Template | National Park Service (NPS) - Denver Service Center (DSC) page 9 of 22

Project Title: First Bank of the United States

SUBMITTAL REQUIREMENTS

(Indicate with X)

INFORMATIONAL ACTION

S P

E C

IF

IC

A T

IO

N

S E

C T

IO

N

P A

R A

G R

A P

H N

U M

B E

R

DESCRIPTION

C E

R T

IF

IC

A T

IO

N

S

O R

A T

O R

Y T

E S

T S

R E

P O

R T

S O

R C

A

LC

U

LA

T

IO

N S

O R

P

LA

N

M A

N U

F A

C T

U R

E R

D A

T A

A N

D I

N S

T R

U C

T

IO

N S

O T

H E

R

S A

M P

LE

S

S H

O P

D R

A W

IN

G

S

M A

N U

F A

C T

U R

E R

D A

T A

A N

D I

N S

T R

U C

T

IO

N S

O T

H E

R

85113 1.4.C Shop drawings - Aluminum windows X

85113 1.4.D Sample - Finish - Aluminum windows X

85113 1.4.E Qualification data - Aluminum window installer X

85113 1.4.E Test reports - Aluminum windows X

85113 1.5.B Mock-up panel - Aluminum window installtion X

87100 1.4.A Product data - Door hardware X

87100 1.4.B Door Hardware Schedule X

87100 1.4.C Shop drawings - Electrified door hardware X

87100 1.4.D Keying Schedule X

87100 1.4.E Product Test Reports X

88000 1.4.A Product data - All specified glass types X

88000 1.4.B Glazing Schedule X

88000 1.4.C Samples - Fritted glass - For pattern selection X

88000 1.4.D Samples - All glass types X

88100 1.5.A Product data - Leaded glass restoration materials X

88100 1.5.B Samples - Replacement glass, came & acrylic sheet X

88100 1.6.C Mock-up panel - Bench restoration of decorative glass X

88100 1.6.C Mock-up panel - In Situ cleaning of decorative glass X

89119 1.3.A Product data - Fixed aluminum louvers X

89119 1.3.B Shop Drawings - Fixed aluminum louvers X

89119 1.3.C Samples - Finish - Fixed aluminum louvers X

90320 1.3.A Product data - Plaster restoration materials X

90320 1.3.B Samples - Replacement plaster castings X

90320 1.3.B Sample - Plastic lath X

90320 1.5.C Mock-up panel - Repair of water-damaged decorative plaster X

90320 1.5.C Mock-up panel - Removal/modification/reinstallation cornice X

92216 1.3.A Shop drawings - Ceiling suspension system X

92216 1.3.B Product data - Ceiling suspension system X

92216 1.3.B Product data - Ceiling access doors X

92216 1.3.B Product data - Metal studs, tracks and accessories X

92216 1.3.C Materials certificates - Metal studs and tracks X

92216 1.3.C Test reports - Firestop tracks, anchors & fasteners X

92300 1.4.A Product data - Flat plaster materials & accessories X

92300 1.5.B Mock-Up Panel - Repair of existing wall plaster X

92300 1.5.B Mock-Up Panel - New plaster on wire lath X

Submittal List with Review Estimate Template | National Park Service (NPS) - Denver Service Center (DSC) page 10 of 22

Project Title: First Bank of the United States

SUBMITTAL REQUIREMENTS

(Indicate with X)

INFORMATIONAL ACTION

S P

E C

IF

IC

A T

IO

N

S E

C T

IO

N

P A

R A

G R

A P

H N

U M

B E

R

DESCRIPTION

C E

R T

IF

IC

A T

IO

N

S

O R

A T

O R

Y T

E S

T S

R E

P O

R T

S O

R C

A

LC

U

LA

T

IO

N S

O R

P

LA

N

M A

N U

F A

C T

U R

E R

D A

T A

A N

D I

N S

T R

U C

T

IO

N S

O T

H E

R

S A

M P

LE

S

S H

O P

D R

A W

IN

G

S

M A

N U

F A

C T

U R

E R

D A

T A

A N

D I

N S

T R

U C

T

IO

N S

O T

H E

R

92900 1.4.A Product data - Gypsum wallboard, fasteners & finishing matls X

93013 1.4.A Shop drawings - Tile layouts X

93013 1.4.B Product data - Cermic tile, setting materials & accessories X

93013 1.4.C Samples - Ceramic tile & grout for color selection X

95113 1.5.A Shop drawings - Acoustic ceiling treatment X

95113 1.5.B Product data - Acoustic ceiling treatment X

95113 1.5.C Samples - Acoustic ceiling treatment X

95113 1.5.D Certification - Acoustic ceiling treatment X

95113 1.5.B Coordination drawings - Acoustic ceiling treatment X

95113 1.5.B Product Test/Research Reports - Acoustic ceiling treatment X X

95113 1.5.B Field Quality Control reports - Acoustic ceiling treatment X

95123 1.4.A Product data - Acoustical tile ceilings X

95123 1.4.B Shop drawings - Acoustical tile ceilings X

95123 1.4.C Samples - Acoustical ceiling tiles X

95123 1.5.A Coordination drawings - Acoustic tile ceilings X

95123 1.5.B Product test reports - Acoustical tile ceilings X

95123 1.5.C Research reports - Acoustical tile ceilings X

96519 1.3.A Product data - Luxury vinyl tile X

96519 1.3.B Samples - Luxury vinyl tile for color selection X

96519 1.3.B Samples - Vinyl cove base for color selection X

96623 1.4.A Shop drawings - Resin matrix terrazzo flooring X

96623 1.4.B Product data - Resin matrix terrazzo and accessory materials X

96623 1.4.C Samples - Resin matrix terrazzo flooring for color selection X

96623 1.4.D Moisture testing reports - Resin matrix terrazzo flooring X

96623 1.6.F Mock-Up Panel - Resin terrazzo flooring X

96816 1.4.A Product data - Sheet carpeting & carpet tile X

96816 1.4.B Shop drawings - Sheet carpeting & carpet tile X

96816 1.4.C Samples - Sheet carpeting & carpet tile X

96816 1.5.A Product test reports - Sheet carpeting & carpet tile X

96816 1.5.B Sample warranties - Sheet carpeting & carpet tile X

97513 1.4.A Shop drawings - Interior stone fabrications X

97513 1.4.B Product data - New interior stone X

97513 1.4.B Product data - Waterproofing membrane X

97513 1.4.B Product data - Marble cleaning and polishing materials X

97513 1.4.C Samples - New marble X

Submittal List with Review Estimate Template | National Park Service (NPS) - Denver Service Center (DSC) page 11 of 22

Project Title: First Bank of the United States

SUBMITTAL REQUIREMENTS

(Indicate with X)

INFORMATIONAL ACTION

S P

E C

IF

IC

A T

IO

N

S E

C T

IO

N

P A

R A

G R

A P

H N

U M

B E

R

DESCRIPTION

C E

R T

IF

IC

A T

IO

N

S

O R

A T

O R

Y T

E S

T S

R E

P O

R T

S O

R C

A

LC

U

LA

T

IO

N S

O R

P

LA

N

M A

N U

F A

C T

U R

E R

D A

T A

A N

D I

N S

T R

U C

T

IO

N S

O T

H E

R

S A

M P

LE

S

S H

O P

D R

A W

IN

G

S

M A

N U

F A

C T

U R

E R

D A

T A

A N

D I

N S

T R

U C

T

IO

N S

O T

H E

R

97513 1.5.A Mock-Up Panel - Cleaning & polishing of existing marble X

97513 1.5.A Mock-Up Panel - New marble wainscot X

99113 1.4.A Product data - Exterior preparation materials, primers & paints X

99113 1.4.B Schedule - All exterior preparation materials, primers & paints X

99113 1.4.C Samples - Standard samples for all required colors X

99113 1.4.D Drawdown samples - All paint colors X

99113 1.4.E Samples - Stain and Finish for Exterior Doors X

99123 1.4.B Product data - Exterior preparation materials, primers & paints X

99123 1.4.A Schedule - All exterior preparation materials, primers & paints X

99123 1.4.C Samples - Standard samples for all required colors X

99123 1.4.D Drawdown samples - All paint colors X

99123 1.4.E Samples - Stain and Finish for Custom Furniture X

99123 1.5.A Mock-Up Panel - Decorative plaster cornice X

99123 1.5.A Mock-Up Panel - Decorative metal railing X

99123 1.5.A Mock-Up Panel - Interior storm window panel X

99123 1.5.A Mock-Up Panel - HVAC grille X

99123 1.5.A Mock-Up Panel - Interior wood door X

99123 1.5.A Mock-Up Panel - Interior brick & stone masonry X

101423 1.4.A Product data - Signage X

101423 1.4.B Shop drawings X

101423 1.4.C Samples - Signage X

101423 1.5.A Sample warranty - Signage X

102113 1.4.A Product data - Toilet partitions X

102113 1.4.B Shop drawings - Toilet partitions X

102113 1.4.C Samples - Toilet partition finish X

102800 1.4.A Product data - Toilet room accessories X

102800 1.4.B Schedule of Toilet room accessories X

102800 1.4.C Sample warranty - Toilet room mirrors X

102900 1.3.A Shop Drawings - Bird deterrent netting X

102900 1.3.B Product data - Bird deterrent netting and fasteners X

102900 1.3.C Samples - Bird deterrent netting and fasteners X

102900 1.3.D Installer certification - Bird deterrent netting X

104416 1.3.A Product data - Fire extinguishers X

104416 1.3.B Schedule of fire extinguishers X

105300 1.3.A Product data - Metal canopy X

Submittal List with Review Estimate Template | National Park Service (NPS) - Denver Service Center (DSC) page 12 of 22

Project Title: First Bank of the United States

SUBMITTAL REQUIREMENTS

(Indicate with X)

INFORMATIONAL ACTION

S P

E C

IF

IC

A T

IO

N

S E

C T

IO

N

P A

R A

G R

A P

H N

U M

B E

R

DESCRIPTION

C E

R T

IF

IC

A T

IO

N

S

O R

A T

O R

Y T

E S

T S

R E

P O

R T

S O

R C

A

LC

U

LA

T

IO

N S

O R

P

LA

N

M A

N U

F A

C T

U R

E R

D A

T A

A N

D I

N S

T R

U C

T

IO

N S

O T

H E

R

S A

M P

LE

S

S H

O P

D R

A W

IN

G

S

M A

N U

F A

C T

U R

E R

D A

T A

A N

D I

N S

T R

U C

T

IO

N S

O T

H E

R

105300 1.3.B Shop drawings - Metal canopy X

105300 1.3.C Design Calculations - Metal canopy X

105300 1.3.D Sample - Metal canopy fascia profile X

105300 1.3.D Sample - Metal canopy finish for color selection X

112213 1.3.A Product data - Security safes X

112213 1.3.B Shop drawings - Security safes X

112213 1.3.C Sample - Finish - Security safes X

122413 1.3.A Product data - Manual roller window shades X

122413 1.3.A Product data - Motorized roller window shades X

122413 1.3.B Shop drawings - Motorized roller window shades X

122413 1.3.C Schedule - Roller window shades X

122413 1.3.D Sample - Fabric and finishes for color selection X

122413 1.3.D Sample - Shade fabric X

123530 1.3.A Product data - Manufactured Cabinetry and Hardware

123530 1.3.A Product data - Solid-surface countertops X

123530 1.3.A Product data - Kitchen appliances X

123530 1.3.B Shop drawings - Manufactured cabinetryu X

123530 1.3.C Catalog Cuts - Kitchen Appliances X

123530 1.3.D Samples - Manufactured cabinetry finishes for color selection X

123530 1.3.D Samples - Solid-surface countertop material X

142400 1.3.A Product data - Hydraulic passenger elevator X

142400 1.3.B Shop drawings - Hydraulic passenger elevator X

142400 1.3.C Samples - Finishes - Hydraulic passenger elevator X

210517 1.3.A Product data - Sleeves for fire suppression piping X

210517 1.3.A Product data - Sleeve/seal systems for fire suppression piping X

210517 1.3.A Product data - Grout for sleeves for fire suppression piping X

210517 1.4.A Field quality reports for sleeves/seals in fire suppression piping X

210518 1.4.A Product data - Escutcheons for fire suppression piping X

210518 1.4.A Product data - Floor plates for fire suppression piping X

210523 1.4.A Product data - Valves for water-based fire suppression piping X

210529 1.3.A Product data - Hangers/supports for fire suppression piping X

210529 1.4.A Welding certificates X

210553 1.3.A Product data - Equip & valve labels for fire suppression piping X

210553 1.3.B Equipment label schedule X

210553 1.3.C Valve numbering scheme / schedule X

Submittal List with Review Estimate Template | National Park Service (NPS) - Denver Service Center (DSC) page 13 of 22

Project Title: First Bank of the United States

SUBMITTAL REQUIREMENTS

(Indicate with X)

INFORMATIONAL ACTION

S P

E C

IF

IC

A T

IO

N

S E

C T

IO

N

P A

R A

G R

A P

H N

U M

B E

R

DESCRIPTION

C E

R T

IF

IC

A T

IO

N

S

O R

A T

O R

Y T

E S

T S

R E

P O

R T

S O

R C

A

LC

U

LA

T

IO

N S

O R

P

LA

N

M A

N U

F A

C T

U R

E R

D A

T A

A N

D I

N S

T R

U C

T

IO

N S

O T

H E

R

S A

M P

LE

S

S H

O P

D R

A W

IN

G

S

M A

N U

F A

C T

U R

E R

D A

T A

A N

D I

N S

T R

U C

T

IO

N S

O T

H E

R

211119 1.3.A Product data / catalog cuts - Fire department connections X

211200 1.4.A Product data - Fire suppression standpipe & specialties X

211200 1.4.B Shop drawings - Fire suppression standpipe system X

211200 1.4.C Delegated design submittal - Fire suppression standpipe sys X

211200 1.5.A Coordination drawings - Fire suppression standpipe system X

211200 1.5.B Qualification data - Engineer/installer - Fire suppression stdpipe X

211200 1.5.C Standpipe drawings/calcs approved by AHJ X 211200 1.5.D Welding certificates - Fire suppression standpipe system X 211200 1.5.E Fire hydrant flow test reports X 211200 1.5.F Field test reports/certificates NFPA 14 X 211200 1.5.G Field quality control reports X 211313 1.4.A Product data - Wet-pipe sprinkler system components X 211313 1.4.B Shop drawings - Wet-pipe sprinkler system X 211313 1.4.C Delegated design submittal - Wet-pipe sprinkler system X 211313 1.5.A Coordinate drawings - Wet-pipe sprinkler system X 211313 1.5.B Qualification data - Engineer/installer wet-pipe sprinkler syst X 211313 1.5.C Design data - Wet-pipe sprinkler system X 211313 1.5.D Welding certificates - Wet-pipe sprinkler system X 211313 1.5.E Field test reports/certificates NFPA 14 X 211313 1.5.E Fire-hydrant flow test X 211313 1.5.F Field quality control reports X 211316 1.4.A Product data - Dry-pipe sprinkler system components X 211316 1.4.B Shop drawings - Dry-pipe sprinkler system X 211316 1.4.C Delegated design submittal - Dry-pipe sprinkler system X 211316 1.5.A Coordination drawings - Dry-pipe sprinkler system X 211316 1.5.B Qualifications - Installer & Engineer - Dry-pipe sprinkler syst X 211316 1.5.C Design data - Dry-pipe sprinkler system X 211316 1.5.D Fire hydrant flow test report X 211316 1.5.E Field test report - Dry-pipe sprinkler system X 211316 1.5.F Field quality-control reports - Dry pipe sprinkler system X 213113 1.4.A Product data - Fire pumps X 213113 1.4.B Product data - Fire pump controllers X 213113 1.4.C Shop drawings - Fire pumps X 213113 1.4.D Shop drawings - Fire pump controllers X 213113 1.5.A Product certificates - Fire pumps X 213113 1.5.B Source quality control reports - Fire pumps 213113 1.5.C Field quality control reports-Fire pumps X 213413 1.3.A Product data - Pressure maintenance pumps X 213413 1.3.B Shop Drawings - Pressure maintenance pumps X 213413 1.4.A Field quality control reports - Pressure maintenance pumps X 220517 1.3.A Product data - Sleeves for plumbing piping X 220517 1.3.A Product data - Sleeve/seal systems for plumbing piping X 220517 1.3.A Product data - Grout for sleeves for plumbing piping X

Submittal List with Review Estimate Template | National Park Service (NPS) - Denver Service Center (DSC) page 14 of 22

Project Title: First Bank of the United States

SUBMITTAL REQUIREMENTS

(Indicate with X)

INFORMATIONAL ACTION

S P

E C

IF

IC

A T

IO

N

S E

C T

IO

N

P A

R A

G R

A P

H N

U M

B E

R

DESCRIPTION

C E

R T

IF

IC

A T

IO

N

S

O R

A T

O R

Y T

E S

T S

R E

P O

R T

S O

R C

A

LC

U

LA

T

IO

N S

O R

P

LA

N

M A

N U

F A

C T

U R

E R

D A

T A

A N

D I

N S

T R

U C

T

IO

N S

O T

H E

R

S A

M P

LE

S

S H

O P

D R

A W

IN

G

S

M A

N U

F A

C T

U R

E R

D A

T A

A N

D I

N S

T R

U C

T

IO

N S

O T

H E

R

220517 1.4.A Field quality reports for sleeves/seals in plumbing piping X 220518 1.4.A Product data - Escutcheons for plumbing piping X 220518 1.4.A Product data - Floor plates for plumbing piping X 220519 1.3.A Product data - Meters and gages for plumbing piping X 220519 1.4.A Product certificates - Meters and gages for plumbing piping X 220523 1.4.A Product data - Ball valves for plumbing piping X 220523 1.4.A Product certificates - Ball valves for plumbing piping X 220523 1.4.A Product data - Swing check valves for plumbing piping X 220523 1.4.A Product certificates - Swing check valves for plumbing piping X 220529 1.3.A Product data - Metal framing supprts for plumbing & equip X 220529 1.4.A Welding certificates - Metal framing supports for plbg & equip X 220553 1.3.A Product data - Plumbing equipment and valve labels & tags X 220553 1.3.B Plumbing equipment label schedule X 220553 1.3.C Valve numbering scheme - Plumbing X 220553 1.3.D Valve schedule - Plumbing system X 220719 1.3.A Product data - Plumbing pipe insulation materials X 220719 1.3.B Shop drawings - Plumbing pipe insulation details X 220719 1.4.A Qualification data - Plumbing insulation installer X 220719 1.4.B Materials test reports - Plumbing insulation materials X 221116 1.3.A Product data - Domestic water piping fittings X 221116 1.4.A System purging and disinfecting report - Domestic water piping X 221116 1.4.B Field quality control reports - Domestic water piping X 221119 1.3.A Product data - Domestic water piping specialties X 221119 1.3.B Shop drawings - Domestic water piping specialties X 221119 1.3.C Sustainable design submittal - Domestic water consumption X 221119 1.4.A Field quality control reports - Domestic water piping specialties X 221123 1.4.A Product data - Domestic water booster pumps X 221123 1.4.B Shop drawings - Domestic water booster pumps X 221123 1.3.A Product data - Inline domestic water pumps X 221123 1.4.A Coordination drawings - Inline domestic water pumps X 221123 1.4.B Field quality control reports - Inline domestic water pumps X 221316 1.3.A Product data - Sanitary waste & vent piping & fittings X 221316 1.4.A Field quality control reports - Sanitary waste & vent piping X 221319 1.3.A Product data - Sanitary waste piping specialties X 221319 1.3.B Shop drawings - Sanitary waste piping specialties X 221319 1.4.A Field quality control reports - Sanitary waste specialties X 223300 1.3.A Product data - Domestic water heaters X 223300 1.3.B Shop drawings - Domestic water heaters X 223300 1.4.A Coordination drawings - Domestic water heaters X 223300 1.4.B Field quality control reports - Domestic water heaters X 223300 1.4.C Sample warranty - Domestic water heaters X 224213 1.4.A Product data - Commercial water closets X 224213 1.4.B Shop drawings - Commercial water closets X 224213 1.4.A Product data - Commercial urinals X

Submittal List with Review Estimate Template | National Park Service (NPS) - Denver Service Center (DSC) page 15 of 22

Project Title: First Bank of the United States

SUBMITTAL REQUIREMENTS

(Indicate with X)

INFORMATIONAL ACTION

S P

E C

IF

IC

A T

IO

N

S E

C T

IO

N

P A

R A

G R

A P

H N

U M

B E

R

DESCRIPTION

C E

R T

IF

IC

A T

IO

N

S

O R

A T

O R

Y T

E S

T S

R E

P O

R T

S O

R C

A

LC

U

LA

T

IO

N S

O R

P

LA

N

M A

N U

F A

C T

U R

E R

D A

T A

A N

D I

N S

T R

U C

T

IO

N S

O T

H E

R

S A

M P

LE

S

S H

O P

D R

A W

IN

G

S

M A

N U

F A

C T

U R

E R

D A

T A

A N

D I

N S

T R

U C

T

IO

N S

O T

H E

R

224213 1.4.B Shop drawings - Commercial urinals X 224216 1.3.A Product data - Commercial lavatories X 224216 1.3.B Shop drawings - Commercial lavatories X 224216 1.4.A Coordination drawings - Commercial lavatories X 224216 1.3.A Product data - Commercial Sinks X 224216 1.4.A Coordination drawings - Commercial sinks X 224716 1.3.A Product data - Pressure water coolers X 224716 1.3.B Shop drawings - Pressure water coolers X 230517 1.3.A Product data - Sleeves for HVAC piping X 230517 1.3.A Product data - Sleeve/seal systems for HVAC piping X 230517 1.3.A Product data - Grout for sleeves for HVAC piping X 230517 1.4.A Field quality reports for sleeves/seals in HVAC piping X 230518 1.4.A Product data - Escutcheons for HVAC piping X 230518 1.4.A Product data - Floor plates for HVAC piping X 230519 1.3.A Product data - Meters and gages for HVAC piping X 230519 1.4.A Product certificates - Meters and gages for HVAC piping X 230523 1.4.A Product data - Ball valves for HVAC piping X 230523 1.4.A Product certificates - Ball valves for HVAC piping X 230523 1.4.A Product data - Butterfly valves for HVAC piping X 230523 1.4.A Product certificates - Butterfly valves for HVAC piping X 230523 1.4.A Product data - Check valves for HVAC piping X 230523 1.4.A Product certificates - Check valves for HVAC piping X 230529 1.3.A Product data - Hangers /Supports for HVAC piping & equip X 230529 1.3.B Shop drawings - Hangers/Supports for HVAC piping & equip X 230529 1.4.A Welding certificates - Hangers/Supports for HVAC piping & eq X 230548 1.3.A Product data - Vibration control for HVAC piping & equip X 230548 1.4.A Coordination drawings - Vibration control for HVAC piping & eq X 230548 1.4.B Qualification data - Testing agency - Vibration control X 230548 1.4.C Welding certificates - Vibration control for HVAC piping & eq X 230553 1.3.A Product data - HVAC equipment and valve labels & tags X 230553 1.3.B HVAC equipment label schedule X 230553 1.3.C Valve numbering scheme - HVAC piping X 230553 1.3.D Valve schedule - HVAC piping X 230593 1.4.A Air-Balance Report X 230593 1.4.A Testing and Balancing Report X 230593 1.5.A Qualification data - Testing and balancing Specialist and team X 230593 1.5.B Contract documents examination report X 230593 1.5.C Strategies and procedures plan X 230593 1.5.D System readiness checklists 230593 1.5.E Examination report X 230593 1.5.F Certified testing and balancing reports X 230593 1.5.G Sample report forms X 230593 1.5.H Instrument calibration reports X 230713 1.3.A Product data - Duct insulation materials X

Submittal List with Review Estimate Template | National Park Service (NPS) - Denver Service Center (DSC) page 16 of 22

Project Title: First Bank of the United States

SUBMITTAL REQUIREMENTS

(Indicate with X)

INFORMATIONAL ACTION

S P

E C

IF

IC

A T

IO

N

S E

C T

IO

N

P A

R A

G R

A P

H N

U M

B E

R

DESCRIPTION

C E

R T

IF

IC

A T

IO

N

S

O R

A T

O R

Y T

E S

T S

R E

P O

R T

S O

R C

A

LC

U

LA

T

IO

N S

O R

P

LA

N

M A

N U

F A

C T

U R

E R

D A

T A

A N

D I

N S

T R

U C

T

IO

N S

O T

H E

R

S A

M P

LE

S

S H

O P

D R

A W

IN

G

S

M A

N U

F A

C T

U R

E R

D A

T A

A N

D I

N S

T R

U C

T

IO

N S

O T

H E

R

230713 1.3.B Shop drawings - Duct insulation details X 230713 1.4.A Qualifications - Duct insulation installer X 230713 1.4.B Material test reports - Duct insulation materials X 230716 1.3.A Product data - HVAC equipment insulation X 230716 1.3.B Sustainability data - Insulation adhesives, sealants & coatings X 230716 1.4.A Qualification data - Insulation installer X 230716 1.4.B Material test reports - HVAC equipment insulation X 230719 1.3.A Product data - HVAC piping insulation X 230719 1.3.B Sustainability data - Insulation adhesives, sealants & coatings X 230719 1.3.C Shop drawings - HVAC piping insulation details X 230719 1.4.A Qualification data - Insulation installer X 230719 1.4.B Material test reports - HVAC PIPING insulation X 230923 1.4.B Product data - DDC system components/materials X 230923 1.4.C Shop drawings - DDC system X 230923 1.4.D DDC System Description X 230923 1.4.A Product data - Control valves for DDC system X 230923 1.4.B Shop drawings - Control valves for DDC system X 230923 1.4.C Delegated design submittal - Control valves for DDC system X 230923 1.5.A Coordination drawings - Control valves for DDC system X 232113 1.3.A Product data - Hydronic piping & fittings X 232113 1.4.A Coordination drawings - Hydronic piping X 232113 1.4.B Qualification data - Hydonic piping installer X 232113 1.4.C Welding certificates - Hydronic piping X 232113 1.4.D Field quality control reports - Hydronic piping X 232116 1.3.A Product data/catalog cuts - Hydronic piping specialties X 232123 1.4.A Product data - Hydronic pumps X 232123 1.4.B Shop drawings - Hydronic pumps X 233113 1.3.A Product data - Metal ductwork adhesives, liners, sealants, etc X 233113 1.3.B Sustainability data - Insulation adhesives, sealants & coatings X 233113 1.3.C Shop drawings - Metal ductwork X 233113 1.4.A Coordination drawings - Metal ductwork X 233300 1.3.A Product data - Air duct accessories X 233300 1.3.B Sustainable design submittal - ASHRAE 62.1 X 233300 1.3.C Shop drawings - Air duct accessories X 233300 1.4.A Coordination drawings - Air duct accessories X 233300 1.4.B Source quality reports - Air duct accessories X 233346 1.3.A Product data - Flexible ductwork X 233346 1.3.B Shop drawings - Flexible ductwork X 233346 1.4.A Coordination drawings - Flexible ductwork X 233423 1.3.A Product data - HVAC power ventilators X 233423 1.3.B Shop drawings - HVAC power ventilators X 233423 1.4.A Coordination drawings - HVAC power ventilators X 233423 1.4.B Field quality-control reports - HVAC power ventilators X 237223 1.3.A Product data - Packaged indoor fixed-plate energy recovery unt X

Submittal List with Review Estimate Template | National Park Service (NPS) - Denver Service Center (DSC) page 17 of 22

Project Title: First Bank of the United States

SUBMITTAL REQUIREMENTS

(Indicate with X)

INFORMATIONAL ACTION

S P

E C

IF

IC

A T

IO

N

S E

C T

IO

N

P A

R A

G R

A P

H N

U M

B E

R

DESCRIPTION

C E

R T

IF

IC

A T

IO

N

S

O R

A T

O R

Y T

E S

T S

R E

P O

R T

S O

R C

A

LC

U

LA

T

IO

N S

O R

P

LA

N

M A

N U

F A

C T

U R

E R

D A

T A

A N

D I

N S

T R

U C

T

IO

N S

O T

H E

R

S A

M P

LE

S

S H

O P

D R

A W

IN

G

S

M A

N U

F A

C T

U R

E R

D A

T A

A N

D I

N S

T R

U C

T

IO

N S

O T

H E

R

237223 1.3.B Shop drawings - Packaged indoor fixed-plate energy recovery u X 237223 1.4.A Coord dwgs - Packaged indoor fixed-plate energy recovery unt X 237223 1.4.B Field quality control reports - Pkgd indoor fix-plt energy recov X 237313 1.3.A Product data - Indoor basic air-handling units X 237313 1.3.B Shop drawings - Indoor basic air-handling units X 237313 1.4.A Coordination drawings - Indoor basic air-handling units X 237313 1.4.B Source quality control reports - Indoor basic air-handling units X 237313 1.4.C Start-up service reports - Indoor basic air-handling units X 237313 1.4.D Field quality control reports - Indoor basic air-handling units X 237313 1.4.E Sample warranty - Indoor basic air-handling units X 237313 1.3.A Product data - Semi-custom air-handling units X 237313 1.3.B Shop drawings - Semi-custom air-handling units X 237313 1.4.A Coordination drawings - Semi-custom air-handling units X 237313 1.4.B Source quality control reports - Semi-custom air-handling units X 237313 1.4.C Start-up service reports - Semi-custom air-handling units X 237313 1.4.D Field quality control reports - Semi-custom air-handling units X 237313 1.4.E Sample warranty - Semi-custom air-handling units X 238123 1.3.A Product data - Small-capacity AC units X 238123 1.3.B Shop drawings - Small capacity AC units X 238123 1.3.C Samples - Color samples AC unit exterior X 238123 1.4.A Coordination drawings - Small-capacity AC units X 238123 1.4.B Field quality-control reports - Small capacity AC units X 238123 1.4.C Sample warranty - Small-capacity AC units X 238219 1.3.A Product data - Fan coil units X 238219 1.3.B Shop drawings - Fan coil units X 238219 1.3.C Finish samples - Fan coil units X 238219 1.4.A Coordination drawings - Fan coil units X 238219 1.4.B Field quality reports - Fan coil units X 238219 1.4.C Sample warranty - Fan coil units X 238236 1.3.A Product data - Finned-tube radation heaters X 238236 1.3.B Shop drawings - Finned-tube radiation heaters X 238236 1.3.C Color samples for initial selection - Finned-tube heaters X 238236 1.3.D Color samples for verification - Finned-tube heaters X 238236 1.4.A Coordination drawings - Finned-tube radiation heaters X 238236 1.4.B Field quality-control reports - Finned-tube radiation heaters X 238239 1.3.A Product data - Propeller Unit heaters X 238239 1.3.B Shop drawings - Propeller unit heaters X 238239 1.4.A Coordination drawings - Propeller unit heaters X 238239 1.4.B Field quality-control reports - Propeller unit heaters X 260519 1.4.A Product data - Low-voltage electrical power conductors/cables X 260519 1.5.A Field quality control reports-Low-voltage elec power cond/cable X 260526 1.4.A Product data - Grounding/bonding systems/equip X 260526 1.4.B Field quality reports - Grounding/bonding systems/equip X 260529 1.3.A Product data - Hangers & supports for electrical systems X

Submittal List with Review Estimate Template | National Park Service (NPS) - Denver Service Center (DSC) page 18 of 22

Project Title: First Bank of the United States

SUBMITTAL REQUIREMENTS

(Indicate with X)

INFORMATIONAL ACTION

S P

E C

IF

IC

A T

IO

N

S E

C T

IO

N

P A

R A

G R

A P

H N

U M

B E

R

DESCRIPTION

C E

R T

IF

IC

A T

IO

N

S

O R

A T

O R

Y T

E S

T S

R E

P O

R T

S O

R C

A

LC

U

LA

T

IO

N S

O R

P

LA

N

M A

N U

F A

C T

U R

E R

D A

T A

A N

D I

N S

T R

U C

T

IO

N S

O T

H E

R

S A

M P

LE

S

S H

O P

D R

A W

IN

G

S

M A

N U

F A

C T

U R

E R

D A

T A

A N

D I

N S

T R

U C

T

IO

N S

O T

H E

R

260529 1.3.B Coordination drawings - Hangers & supports for electrical syst X 260533 1.4.A Product data - Raceways & boxes for electrical systems X 260533 1.4.B Shop drawings - Custom raceways, boxes & enclosures X 260543 1.4.A Product data - Underground ducts & raceways for electrical X 260543 1.5.A Field quality control reports - Undeground ducts & raceways X 260544 1.3.A Product data - Sleeves & seals for electrical raceways X 260544 1.3.A Product data - Grout & sealants for electrical raceways & cable X 260553 1.3.A Product data - Signs, labels, ID scheme for electrical systems X 260573 1.3.A Product data - Software to be used for overcurrent study X 260573 1.3.B Sample arc flash label X 260573 1.3.C Calculations for overcurrent protection X 260573 Overcurrent protection device study X 260923 1.3.A Product data - Lighting control system/devices X 260923 1.3.B Shop drawings - Lighting control system/devices X 260923 1.4.A Sample field test report form - Lighting control system X 260923 1.4.B Field quality control reports - Lighting control system X 260923 1.4.C Sample warranty - Lighting control system X 260923 1.4.D List of maintenance materials/spare parts - lighting control X 262213 1.3.A Product data - Low-voltage distribution transformers X 262213 1.3.B Shop drawings - Low-voltage distribution transformers X 262213 1.4.A Field quality control reports - Low-voltage distribution transform X 262416 1.4.A Product data - Electrical panelboards & accessories X 262416 1.4.B Shop drawings - Electrical panelboards & accessories X 262416 1.5.A Field quality control reports - Panelboards X 262416 1.5.B Sample warranty - Surge protection devices X 262416 1.5.C List of maintenance materials/spare parts - Panelboards X 262713 1.4.A Product data - Electricity meters & software X 262713 1.4.B Shop drawings - Electricity meters X 262713 1.5.A Coordination drawings - Electricity meters X 262713 1.5.B Field quality control reports - Electricity meters X 262713 1.5.C Sample warranty - Electricity meters X 262726 1.4.A Product data - Wiring devices X 262726 1.5.A Field quality control reports - Wiring devices X 262813 1.3.A Product data - Fuses X 262816 1.4.A Product data - Switches & Circuit breakers X 262816 1.4.B Shop drawings - Switches & Circuit breakers X 262816 1.5.A Field quality control reports - Switches & circuit breakers X 262913 1.4.A Product data - Manual & magnetic motor controllers X 262913 1.5.A Field quality control reports - Motor controllers X 262913 1.5.B List of maintenance materials/spare parts - Controllers X 262923 1.4.A Product data - Variable-frequency motor controllers X 262923 1.4.B Shop drawings - Variable-frequency motor controllers X 262923 1.5.A Field quality-control reports - Variable frequency motor control X 262923 1.5.B Sample warranty - Variable frequency motor controllers X

Submittal List with Review Estimate Template | National Park Service (NPS) -…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .