B08_Attach_153_REV_1st_Bank_061600_Sheathing_0007.pdf

PDF 106 KB Posted

Attached to
INDE 245589, Rehabilitation of First Bank, Indepen
Solicitation number
140P2023R0002
Issued by

About this file

This document provides specifications for sheathing materials and installation requirements for the rehabilitation of First Bank in Independence National Historical Park in Philadelphia, Pennsylvania. Key requirements include the use of fire-retardant wood roof and parapet sheathing, plywood roof sheathing, glass-mat gypsum wall sheathing, and cement board wall sheathing for thin brick installation. Acceptable sheathing products are specified along with performance standards. Installation standards are also outlined for wood structural panels, gypsum sheathing, cementitious backer units, and replacement boards at existing buildings. The related federal contract opportunity is for project number INDE 245589 to rehabilitate the interior and exterior of First Bank under solicitation number 140P2023R0002 issued by the Department of the Interior National Park Service National Office.

View the file

Other files

File Type Posted
Sol_140P2023R0002_Amd_0008.pdf PDF
INDE_245589_Final_questions_and_answers_0008.xlsx XLSX spreadsheet
B08_Attach_125_REV_A7_12-_3RD_FLR_ADDN_FLOORING_PATTERN_0007.pdf PDF
B08_Attach_139_REV_1st_Bank_01_27_00_1A_ContractPriceSchedule_0007.pdf PDF
B08_Attach_117_REV_A3_3-TRANS_SECTS_THRU_ADDN_0007.pdf PDF
B08_Attach_141_REV_1st_Bank_01_22_00B_Unit_Prices_0007.pdf PDF
B08_Attach_148_REV_A8_15-_DECOR_PLASTER___TRENCH_DTLS_0007.pdf PDF
B08_Attach_126_REV_A8_1-FIRST_FLR_INT_ELEVS_0007.pdf PDF
B08_Attach_93_REV_1st_Bank_028214_Asbestos_Remediation_0007.pdf PDF
B08_Attach_104_REV_1st_Bank_142400A_Hydraulic_Elevators_0007.pdf PDF
B08_Attach_94_REV_1st_Bank_042000_Unit_Masonry_0007.pdf PDF
B08_Attach_158_REV__096623_Resin_Matrix_Terrazzo_Flooring_0007.pdf PDF
B08_Attach_115_REV_A2_2-WEST_ELEV_0007.pdf PDF
B08_Attach_133_REV_A9_6-EX_RAILING_MODIFICATIONS_0007.pdf PDF
B08_Attach_157_REV_1st_Bank_096519_Vinyl_Tile_0007.pdf PDF
B08_Attach_90_REV_C1_0_EXIST_COND___DEMO_OVERALL_PLAN_0007.pdf PDF
B08_Attach_143_REV_A2_3-SOUTH_ELEV_0007.pdf PDF
B08_Attach_136_REV_1st_Bank_01_40_00_Quality_Requirements_0007.pdf PDF
B08_Attach_113_REV_A2_0C-PORTICO_ELEV_EXT_REHAB_0007.pdf PDF
B08_Attach_161_REV_1st_Bank_142400B_Hydraulic_Elevators_0007.pdf PDF
B08_Attach_155_REV_084123_FireRated_Glass_and_Framing_Systems_0007.pdf PDF
B08_Attach_98_REV_1st_Bank_057313_Glazed_Decorative_Metal_Railings_0007.pdf PDF
B08_Attach_111_REV_A1_9A-ATTIC___3RD_FLR_SLAB_EDGE_PLN_ADDN_0007.pdf PDF
B08_Attach_160_REV_1st_Bank_122413A_Roller_Window_Shades_0007.pdf PDF
B08_Attach_119_REV_A6_7-_DOOR___FRAME_DETAILS_0007.pdf PDF
B08_Attach_156_REV_1st_Bank_088000_Glass_and_Glazing_0007.pdf PDF
B08_Attach_116_REV_A2_3-SOUTH_ELEV_0007.pdf PDF
B08_Attach_135_G1_0_SHEET_INDEX_0007.pdf PDF
B08_Attach_142_REV_01_27_00_DefinitionofContracLineItems_0007.pdf PDF
B08_Attach_109_REV_A1_8A-2ND_FLR_SLAB_EDGE_PLN_ADDN_0007.pdf PDF
B08_Attach_129_REV_A8_4-2ND_FLR_INT_ELEVS_0007.pdf PDF
B08_Attach_130_REV_A8_6-_3RD_FLR_INT_ELEVS_0007.pdf PDF
B08_Attach_138_REV_1st_Bank_017700_1_Closeout_OM_Requirements_0007.pdf PDF
B08_Attach_110_REV_A1_9-3RD_FLR_PLN_ADDN_0007.pdf PDF
B08_Attach_145_REV_A6_13-WDO_SCHED___DTLS_0007.pdf PDF
B08_Attach_106_REV_A1_5-BSMT_FLR_PLN_ADDN_0007.pdf PDF
B08_Attach_101_REV_1st_Bank_084413_Glazed_Aluminum_Curtain_Walls_0007.pdf PDF
B08_Attach_149_REV_A9_8_-_STAIR_RAILING___ADDITION_0007.pdf PDF
B08_Attach_92_REV_1st_Bank_015000_Temporary_Facilities_And_Controls_0007.pdf PDF
B08_Attach_146_REV_A8_0-FINISH_SCHED___DTLS_0007.pdf PDF
B08_Attach_123_REV_A7_10-1ST_FLR_ADDN_FLOORING_PATTERN_0007.pdf PDF
B08_Attach_150_REV_C3_0_Utility_Plan_0007.pdf PDF
B08_Attach_107_REV_A1_6-1ST_FLR_PLN_ADDN_0007.pdf PDF
B08_Attach_124_REV_A7_11-_2ND_FLR_ADDN_FLOORING_PATTERN_0007.pdf PDF
B08_Attach_137_REV_1st_Bank01_27_00_1AContractPriceSchedule_0007.xlsx XLSX spreadsheet
B08_Attach_105_REV_A1_4-ROOF_PLN_0007.pdf PDF
B08_Attach_100_REV_1st_Bank_076200_Flashing_and_Sheet_Metal_0007.pdf PDF
B08_Attach_151_REV_G0_0_COVER_0007.pdf PDF
B08_Attach_114_REV_A2_1-NORTH_ELEV_0007.pdf PDF
B08_Attach_121_REV_A7_1_1ST_FLR_RCP_0007.pdf PDF
Show 40 more

Latest 50 of 185 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

INDE-391-186336 06 16 00 - 1

PMIS 245589 SHEATHING

SECTION 06 16 00 -- SHEATHING

PART 1 – GENERAL

1.1 SUMMARY

A. The work of this section includes, but is not necessarily limited to, the following:

1. Fire-retardant wood roof and parapet sheathing

2. Plywood roof sheathing

3. Gypsum wall sheathing

4. Cement board wall sheathing for thin brick installation

5. Replacement board sheathing at existing building

1.2 RELATED WORK

A. Division 1 requirements

B. Section 05 40 00, “Cold-Formed Metal Framing”

C. Section 06 10 00, “Rough Carpentry”

D. Section 07 21 00, “Thermal Insulation”

E. Section 07 27 26, “Weather Barriers”

F. Section 07 61 00, “Sheet Metal Roofing”

1.3 SUBMITTALS

A. Product Data: Submit manufacturer’s product data for the following hardware and materials:

1. Fasteners and hardware

2. Plywood sheathing

3. Gypsum sheathing

4. Cement board

1.4 QUALITY ASSURANCE

A. Fire Resistance Ratings: ASTM E 119

1.5 DELIVERY, STORAGE AND HANDLING

INDE-391-186336 06 16 00 - 2

A. Store sheathing materials off the ground on pallets or dunnage and loosely covered with a waterproof membrane. Protect from soiling, breakage, impact or other damage.

1.6 PROJECT CONDITIONS

A. Coordinate installation of wall, parapet and roof sheathing with other trades affected by the work of this section to avoid damage to finished work and delays to the project schedule.

PART 2 -- PRODUCTS

2.1 PERFORMANCE REQUIREMENTS

A. Plywood roof sheathing: Either DOC PS 1 or DOC PS 2, Exterior, Structural 1.

B. Fire-Resistance Ratings: As tested according to ASTM E 119; testing by a qualified testing agency.

Identify products with appropriate markings of applicable testing agency.

1. Fire-Resistance Ratings: Indicated by design designations from UL's "Fire Resistance Directory" or from the listings of another qualified testing agency.

2.2 FIRE-RETARDANT TREATMENT

A. General: Where fire-retardant-treated materials are indicated, use materials complying with requirements in this article that are acceptable to authorities having jurisdiction and with fire-test-response characteristics specified as determined by testing identical products per test method indicated by a qualified testing agency.

B. Fire-Retardant-Treated Plywood by Pressure Process: Products with a flame-spread index of 25 or less when tested according to ASTM E 84, and with no evidence of significant progressive combustion when the test is extended an additional 20 minutes, and with the flame front not extending more than 10.5 feet beyond the centerline of the burners at any time during the test.

1. Exterior Type: Treated materials shall comply with requirements specified above for fire-retardant-treated plywood by pressure process after being subjected to accelerated weathering according to ASTM D 2898. Use for exterior locations and where indicated.

C. Design Value Adjustment Factors: Treated lumber plywood shall be tested according to ASTM D 5516 and design value adjustment factors shall be calculated according to ASTM D 6305. Span ratings after treatment shall be not less than span ratings specified. For roof sheathing and where high-temperature fire-retardant treatment is indicated, span ratings for temperatures up to 170 deg F shall be not less than span ratings specified.

D. Kiln-dry material after treatment to a maximum moisture content of 15 percent.

E. Identify fire-retardant-treated plywood with appropriate classification marking of qualified testing agency.

F. Application: Treat plywood indicated on Drawings.

INDE-391-186336 06 16 00 - 3

2.3 GYPSUM SHEATHING

A. Glass-Mat Gypsum Sheathing: ASTM C 1177.

1. Thickness: 1/2 inch.

2. Width: 4 feet.

3. Length: 8 feet.

4. Weight: 1.9 lb/sq. ft.

5. Edges: Square.

6. Surfacing: Fiberglass mat on face, back, and long edges.

7. Racking Strength (Ultimate, not design value) (ASTM E72): Not less than 540 pounds per square foot, dry.

8. Flexural Strength, Parallel (ASTM C473): 80 lbf, parallel.

9. Humidified Deflection (ASTM C1177): Not more than 2/8 inch.

10. Permeance (ASTM E96): Not less than 23 perms.

11. R-Value (ASTM C518): 0.56.

12. Mold Resistance (ASTM D3273): 10, in a test as manufactured.

13. Microbial Resistance (ASTM D6329, UL Environmental GREENGUARD 3-week protocol):

Will not support microbial growth.

B. Acceptable Products:

1. DensGlass Sheathing; Georgia Pacific

2. Gold Bond eXP Sheathing; National Gypsum

3. Securerock Glass Mat Sheathing, US Gypsum

4. Contracting Officer-approved equivalent.

2.4 CEMENT BOARD SHEATHING

INDE-391-186336 06 16 00 - 4

A. Cement Board: ASTM C1325; ½ inch thickness. Approved for use in ASTM C 1780 masonry veneer installations. Provide one of the following products:

1. PermaBase, PermaBase Building Products, Charlotte, NC

2. Durock, United States Gypsum,

3. Contracting Officer-approved equivalent

2.5 REPLACEMENT BOARD SHEATHING

A. Lumber: DOC PS 20 and applicable rules of grading agencies indicated. If no grading agency is indicated, comply with the applicable rules of any rules-writing agency certified by the ALSC Board of Review. Grade lumber by an agency certified by the ALSC Board of Review to inspect and grade lumber under the rules indicated.

1. Factory mark each piece of lumber with grade stamp of grading agency.

B. Replacement Sheathing Boards: 19 percent maximum moisture content and any of the following species and grades:

1. Mixed southern pine or southern pine; No.2 grade; SPIB.

2. Eastern softwoods; No. 2 Common grade; NeLMA.

3. Northern species; No. 2 Common grade; NLGA.

C. Thickness: 1½ inches to match existing

D. Width: To match existing

2.6 FASTENERS AND ACCESSORIES

A. Wood Fasteners

1. Hot-dipped galvanized or stainless steel

B. Gypsum and Cement Board Fasteners

1. Steel drill screws with corrosion-resistant coating

C. Cement Board Accessories

1. Alkali-resistant, glass-fiber joint tape

INDE-391-186336 06 16 00 - 5

PART 3 - EXECUTION

3.1 INSTALLATION, GENERAL

A. Do not use materials with defects that impair quality of sheathing or pieces that are too small to use with minimum number of joints or optimum joint arrangement. Arrange joints so that pieces do not span between fewer than three support members.

B. Cut panels at penetrations, edges, and other obstructions of work; fit tightly against abutting construction unless otherwise indicated.

C. Securely attach to substrate by fastening as indicated, complying with the following:

1. Table 2304.9.1, "Fastening Schedule," in the ICC's International Building Code.

2. ICC-ES evaluation report for fastener.

D. Coordinate wall, parapet and roof sheathing installation with flashing and joint-sealant installation so these materials are installed in sequence and manner that prevent exterior moisture from passing through completed assembly.

E. Do not bridge building expansion joints; cut and space edges of panels to match spacing of structural support elements.

3.2 WOOD STRUCTURAL PANEL INSTALLATION

A. General: Comply with applicable recommendations in APA Form No. E30, "Engineered Wood Construction Guide," for types of structural-use panels and applications indicated.

B. Fastening Methods: Fasten panels as indicated below:

1. Parapet and Roof Sheathing:

a. Nail to wood framing.

b. Screw to cold-formed metal framing.

c. Space panels 1/8 inch apart at edges and ends.

3.3 GYPSUM SHEATHING INSTALLATION

A. Comply with GA-253 and with manufacturer's written instructions.

1. Fasten gypsum sheathing to wood framing with nails or screws.

2. Fasten gypsum sheathing to cold-formed metal framing with screws.

3. Install panels with a 3/8-inch gap where non-load-bearing construction abuts structural elements.

INDE-391-186336 06 16 00 - 6

4. Install panels with a 1/4-inch gap where they abut masonry or similar materials that might

3.4 CEMENTITIOUS BACKER UNIT INSTALLATION

A. Install panels and treat joints according to ANSI A108.11 and manufacturer's written instructions for type of application indicated.

3.5 REPLACEMENT BOARD SHEATHING

A. Cut deteriorated portion of existing sheathing boards back to mid-point of the nearest supports.

B. Install replacement board(s), leaving 1/8-inch gap. at each end. Fasten with galvanized or stainless steel screws of sufficient length to penetrate framing 1½” inches.

END OF SECTION 06 16 00

1. Fire-retardant wood roof and parapet sheathing
2. Plywood roof sheathing
3. Gypsum wall sheathing
4. Cement board wall sheathing for thin brick installation
5. Replacement board sheathing at existing building
A. Product Data: Submit manufacturer’s product data for the following hardware and materials:
1. Fasteners and hardware
2. Plywood sheathing
3. Gypsum sheathing
4. Cement board
2.1 PERFORMANCE REQUIREMENTS
A. Plywood roof sheathing: Either DOC PS 1 or DOC PS 2, Exterior, Structural 1.
B. Fire-Resistance Ratings: As tested according to ASTM E 119; testing by a qualified testing agency. Identify products with appropriate markings of applicable testing agency.
1. Fire-Resistance Ratings: Indicated by design designations from UL's "Fire Resistance Directory" or from the listings of another qualified testing agency.
A. General: Where fire-retardant-treated materials are indicated, use materials complying with requirements in this article that are acceptable to authorities having jurisdiction and with fire-test-response characteristics specified as determined by t...
B. Fire-Retardant-Treated Plywood by Pressure Process: Products with a flame-spread index of 25 or less when tested according to ASTM E 84, and with no evidence of significant progressive combustion when the test is extended an additional 20 minutes, ...
1. Exterior Type: Treated materials shall comply with requirements specified above for fire-retardant-treated plywood by pressure process after being subjected to accelerated weathering according to ASTM D 2898. Use for exterior locations and where in...
C. Design Value Adjustment Factors: Treated lumber plywood shall be tested according to ASTM D 5516 and design value adjustment factors shall be calculated according to ASTM D 6305. Span ratings after treatment shall be not less than span ratings spec...
D. Kiln-dry material after treatment to a maximum moisture content of 15 percent.
E. Identify fire-retardant-treated plywood with appropriate classification marking of qualified testing agency.
F. Application: Treat plywood indicated on Drawings.
2.3 GYPSUM SHEATHING
A. Glass-Mat Gypsum Sheathing: ASTM C 1177.
1. Thickness: 1/2 inch.
2. Width: 4 feet.
3. Length: 8 feet.
4. Weight: 1.9 lb/sq. ft.
5. Edges: Square.
6. Surfacing: Fiberglass mat on face, back, and long edges.
7. Racking Strength (Ultimate, not design value) (ASTM E72): Not less than 540 pounds per square foot, dry.
8. Flexural Strength, Parallel (ASTM C473): 80 lbf, parallel.
9. Humidified Deflection (ASTM C1177): Not more than 2/8 inch.
10. Permeance (ASTM E96): Not less than 23 perms.
11. R-Value (ASTM C518): 0.56.
12. Mold Resistance (ASTM D3273): 10, in a test as manufactured.
13. Microbial Resistance (ASTM D6329, UL Environmental GREENGUARD 3-week protocol): Will not support microbial growth.
B. Acceptable Products:
1. DensGlass Sheathing; Georgia Pacific
2. Gold Bond eXP Sheathing; National Gypsum
3. Securerock Glass Mat Sheathing, US Gypsum
4. Contracting Officer-approved equivalent.
2.4 CEMENT BOARD SHEATHING
A. Cement Board: ASTM C1325; ½ inch thickness. Approved for use in ASTM C 1780 masonry veneer installations. Provide one of the following products:
1. PermaBase, PermaBase Building Products, Charlotte, NC
2. Durock, United States Gypsum,
A. Lumber: DOC PS 20 and applicable rules of grading agencies indicated. If no grading agency is indicated, comply with the applicable rules of any rules-writing agency certified by the ALSC Board of Review. Grade lumber by an agency certified by the ...
1. Factory mark each piece of lumber with grade stamp of grading agency.
B. Replacement Sheathing Boards: 19 percent maximum moisture content and any of the following species and grades:
1. Mixed southern pine or southern pine; No.2 grade; SPIB.
2. Eastern softwoods; No. 2 Common grade; NeLMA.
3. Northern species; No. 2 Common grade; NLGA.
PART 3 - EXECUTION
3.1 INSTALLATION, GENERAL
A. Do not use materials with defects that impair quality of sheathing or pieces that are too small to use with minimum number of joints or optimum joint arrangement. Arrange joints so that pieces do not span between fewer than three support members.
B. Cut panels at penetrations, edges, and other obstructions of work; fit tightly against abutting construction unless otherwise indicated.
C. Securely attach to substrate by fastening as indicated, complying with the following:
1. Table 2304.9.1, "Fastening Schedule," in the ICC's International Building Code.
2. ICC-ES evaluation report for fastener.
D. Coordinate wall, parapet and roof sheathing installation with flashing and joint-sealant installation so these materials are installed in sequence and manner that prevent exterior moisture from passing through completed assembly.
E. Do not bridge building expansion joints; cut and space edges of panels to match spacing of structural support elements.
3.2 WOOD STRUCTURAL PANEL INSTALLATION
A. General: Comply with applicable recommendations in APA Form No. E30, "Engineered Wood Construction Guide," for types of structural-use panels and applications indicated.
B. Fastening Methods: Fasten panels as indicated below:
1. Parapet and Roof Sheathing:
a. Nail to wood framing.
b. Screw to cold-formed metal framing.
c. Space panels 1/8 inch apart at edges and ends.
3.3 GYPSUM SHEATHING INSTALLATION
A. Comply with GA-253 and with manufacturer's written instructions.
1. Fasten gypsum sheathing to wood framing with nails or screws.
2. Fasten gypsum sheathing to cold-formed metal framing with screws.
3. Install panels with a 3/8-inch gap where non-load-bearing construction abuts structural elements.
4. Install panels with a 1/4-inch gap where they abut masonry or similar materials that might
3.4 CEMENTITIOUS BACKER UNIT INSTALLATION
A. Install panels and treat joints according to ANSI A108.11 and manufacturer's written instructions for type of application indicated.
3.5 REPLACEMENT BOARD SHEATHING
A. Cut deteriorated portion of existing sheathing boards back to mid-point of the nearest supports.
B. Install replacement board(s), leaving 1/8-inch gap. at each end. Fasten with galvanized or stainless steel screws of sufficient length to penetrate framing 1½” inches.
C.

File details come from the government source that posted it. Updated .