2018_BR-Bridge_Inspection_report_0007.pdf

PDF 1 MB Posted

Attached to
NOCA Stehekin Fire Fighting Facilities Federal contract opportunity
Solicitation number
140P2022R0018
Issued by
Department of the Interior National Park Service National Office

About this file

This document is a bridge inspection report summarizing the condition of the Harlequin Bridge located in North Cascades National Park. The bridge is a two-span steel warren through truss structure in good overall condition, carrying Company Creek Road over the Stehekin River. It was built in 2001 and is 167 feet long with a 20-foot wide timber deck. The report recommends minor maintenance including fastening loose planks, replacing deteriorated planks, cleaning debris, placing riprap, and trimming vegetation. Consideration should also be given to installing approach guardrail for improved safety. The inspection team found the bridge to be in good condition with only routine maintenance needed at this time.

View the file

Other files for this federal contract opportunity

Other files attached to NOCA Stehekin Fire Fighting Facilities, newest first.
File Type Posted
Sol_140P2022R0018_Amd_0008.pdf PDF
NOCA_Closeout-OperationMaintenance-Requirements_0008.pdf PDF
StatementOfStructuralTestsSpecialInspections_Cache_0008.pdf PDF
StatementOfStructuralTestsSpecialInspections_Booster_Pump_House_0008.pdf PDF
NOCA_Fire_Cache_-_Submittal_List_0008.pdf PDF
StatementOfStructuralTestsSpecialInspections_Generator_Shed_0008.pdf PDF
StatementOfStructuralTestsSpecialInspections_Dorm_0008.pdf PDF
NOCA_Geotech_FOR_PRINT_0007.pdf PDF
B08_QR_Tracker_140P2022R0018_-_NOCA_Fire_-Amend_7_0007.xlsx XLSX spreadsheet
Sol_140P2022R0018_Amd_0007.pdf PDF
22_07_12_-Additional_Tree_Price_List_0006.docx DOCX document
Sol_140P2022R0018_Amd_0006.pdf PDF
B08_Attach_15_Solicitation_Amendment_005_Desc_of_Changes_0005.docx DOCX document
Sol_140P2022R0018_Amd_0005.pdf PDF
B08_Attach_13_Fire_Facilities_PreBid_Mtg_DRAFT-_0004.pdf PDF
B11_Attach_14_Site_Visit_Tri_Fold_NOCA_Fire__0004.docx DOCX document
Sol_140P2022R0018_Amd_0004.pdf PDF
Sol_140P2022R0018_Amd_0003.pdf PDF
B08_Attach_4Vaccination_Certification_Notification_0002.pdf PDF
B08_Attach_12_Solicitation_Amend_02_Desc_of_Changes_0002.docx DOCX document
Sol_140P2022R0018_Amd_0002.pdf PDF
B08_Attach_11_REVISED_CertificationVaccinationPRAv7_0002.pdf PDF
B08_140P2022R0018_Solicit_package_Amend_01_0001.pdf PDF
Solicitation_Amend_01_Desc_of_Changes_0001.docx DOCX document
Sol_140P2022R0018_Amd_0001.pdf PDF
B08_Attach_3__WD_WA20220006.pdf PDF
Sol_140P2022R0018.pdf PDF
B08_140P2022R0018_Solicit_package.pdf PDF
B08_Attach_4Vaccination_Certification_Notification.pdf PDF
B08_Attach_2_Drawings.pdf PDF
B08_Attach_1_Specifications.pdf PDF
B08_Attach_8_Site_Visit_Information_and_Agenda.pdf PDF
B08_Attach_6_Subcontracting_Plan.doc DOC document
B08_Attach_5_Cert_of_Vaccination.pdf PDF
B08_Attach_7__Past_Performance_Questionnaire.docx DOCX document
Show all 35

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STRUCTURE SUMMARY STRUCTURE NO. 9470-011P

HARLEQUIN BRIDGE INSPECTION DATE: 8/27/18

BRIDGE IDENTIFICATION AND DESCRIPTION

MAIN SPAN MATERIAL:

MAIN SPAN TYPE:

# OF BEAMS, MAIN SPAN: ..

DECK TYPE:

WEARING SURFACE:

ABUT. FOUNDATIONS:

PIER FOUNDATION(S):

ABUTMENT / PIER MAT'L: ...

PROJ./PLAN REF. NO:

NPS ROAD CLASS:

STRUCTURE HISTORY:

STEEL

TRUSS - THRU

WOOD OR TIMBER

WOOD OR TIMBER

SPREAD FOOTING ON PILES

N/A / SPREAD FTG ON BEARING MAT'L

CONCRETE

NOCA 10(3) / RG2633

3 - SPECIAL PURPOSE

LOCATION

NO. OF MAIN SPANS:

NO. OF APPR. SPANS:

STRUCT. TOTAL LENGTH: ..

MAX. SPAN LENGTH:

DECK WIDTH:

CURB TO CURB WIDTH:

YEAR BUILT:

YEAR RECONSTRUCTED: ..

SKEW ANGLE:

FRACTURE CRITICAL:

167.3 FT (51.0 M)

162.7 FT (49.6 M)

20.3 FT (6.2 M)

15.4 FT (4.7 M)

N/A

0 °

YES

NORTH CASCADES NATIONAL PARK MILE POINT: ..................... 0.01 (KM PT 0.02)

STATE: ................................. WASHINGTON LOCATION: 1.2 Miles from Maintenance Center.

FACILITY CARRIED: ............ COMPANY CREEK ROAD

FEATURE INTERSECTED: .. STEHEKIN RIVER

STRUCTURE EVALUATION SUMMARY

This weathering steel warren thru-truss bridge is in good condition overall, and only minor maintenance is needed at this time. The recommended maintenance includes fastening loose timber running planks and replacing deteriorated planks tighten the fasteners in the railing posts at rail splice connections cleaning debris off bridge components placing engineered riprap at the abutments and trimming/removing vegetation that is growing near the bridge.

Consideration should also be given to installing an approach guardrail system to help improve motorist safety.

INSPECTION TEAM: J. HENSLEY, S. LOFTUS

CONDITION ASSESSMENT:

JORDAN HENSLEY, P.E., FIELD TEAM LEADER 360-619-7910

REPORT REVIEW:

MARCUS MILLER, P.E., BRIDGE INSPECTION ENGINEER 703-404-6252

REPORT APPROVAL: DATE: 1/3/19

JORGOMAI CEESAY, PH.D., P.E., BIP SUPERVISORY ENGINEER 703-404-6244

STRUCTURE LOAD RATING STRUCTURE NO. 9470-011P

TRUCK TYPE

INVENTORY RATING (NORMAL TRAFFIC) OPERATING RATING (MAXIMUM LOAD)

TONS METRIC TONS TONS METRIC TONS

H 40 36 47 43

HS 43 39 50 45

TYPE 3 42 38 49 44

TYPE 3S2 47 43 53 48

TYPE 3-3 50 45 57 52

DESIGN LOADING: HS20 (MS18)

X CAPACITY MEETS OR EXCEEDS DESIGN LOAD

CAPACITY IS LESS THAN DESIGN LOAD

X ORIGINAL LOAD RATING CALCULATION APPLICABLE

ORIGINAL LOAD RATING CALCULATION REVISED

DATE OF LOAD RATING CALCULATION: 7/16

LOAD RATING CONTROLLED BY:

REMARKS: SEE BRIDGE FILE FOR LOAD RATING CALCULATIONS.

STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 9470-011P

STRUCTURE IDENTIFICATION

(201) PARK: NORTH CASCADES NATIONAL PARK

(202) STRUCTURE NAME: .......... HARLEQUIN BRIDGE

(203) STRUCTURE KIND: ............1 - BRIDGE

(204) STRUCTURE NUMBER: ..... 9470-011P

(205) NPS REGION: .................... 6 - PACIFIC WEST

(206) ROUTE CODE NUMBER: ... 100

(207) ROAD SECTION NO: ..........011P

(208) NPS ROAD CLASS: ............ 3 - SPECIAL PURPOSE

(209) WITHIN NPS BNDRY?: .......YES

(210) OPERATING UNIT: ............. STEHEKIN

(211) PROJECT NO(S): ................NOCA 10(3)

(212) DRAWING NUMBERS: ....... RG2633

(21) MAINTAINED BY: ................. 66 - NATIONAL PARK SERVICE

(22) OWNER: ............................... 66 - NATIONAL PARK SERVICE

(1) STATE:

(2) STATE HWY. AGENCY DIST:

(3) COUNTY CODE:

(4) CITY/PLACE CODE:

(5) INVENTORY ROUTE:

(6) FEATURES INTERSECTED:

(7) FACILITY CARRIED:

(8) STATE STRUCTURE NO:

(9) LOCATION:

(10) INV. RTE. - MIN. VERT. CLR: ..

(11) MILE POINT:

(27) YEAR BUILT:

(106) YEAR RECONSTRUCTED:

(20) TOLL:

(37) HISTORICAL DESIGNATION: ..

530 - WASHINGTON (WA)

007 - CHELAN

168001000

STEHEKIN RIVER

COMPANY CREEK ROAD

9470011P0000000

1.2 Miles from Maintenanc

11.00 FT (3.35 M)

0.01 (KM PT 0.02)

N/A

3 - FREE ROAD

3 - POSSIBLY ELIGIBLE

STRUCTURE DESCRIPTION, FOUNDATION, AND DECK TYPE

(43A) MAIN STR. MATERIAL: ..

(43B) MAIN STR. TYPE:

(45) NO. OF MAIN SPANS:

(48) MAX. SPAN LENGTH:

(49) STRUCTURE LENGTH:

(216A) ABUTMENT #1 FDN:

(216B) ABUTMENT #2 FDN:

(217A) PREDOM. PIER FDN.: ..

(217B) SECOND. PIER FDN: ...

(107) DECK TYPE:

3 - STEEL

10 - TRUSS - THRU

162.7 FT (49.6 M)

167.3 FT (51.0 M)

3 - SPREAD FOOTING ON PILES

3 - SPREAD FOOTING ON PILES

6 - N/A

2 - SPREAD FTG ON BEARING MAT'L

8 - WOOD OR TIMBER

(44A) APPR. STR. MATERIAL: ........ 0 - OTHER

(44B) APPR. STR. TYPE: ................ 00 - OTHER

(46) NO. OF APPROACH SPANS: .. 2

(108) WEAR SURFACE/PROTECT SYSTEM:

A) TYPE WEARING SURFACE: .. 7 - WOOD OR TIMBER

B) TYPE MEMBRANE: ................. 0 - NONE

C) TYPE PROTECTION: .............. 0 - NONE

(218) IS SALT USED?: ..................... NO

LOAD RATING AND POSTING

(31) DESIGN LOAD: ................. 5 - HS20 (MS18) (41) LOAD RESTRICTION: ......... A - OPEN, NO RESTRICTION

(66) INVENTORY RATING: ...... 43.0 TONS (39.0 METRIC TONS) (70) BRIDGE POSTING: .............. 5 - NO POSTING REQUIRED

(64) OPERATING RATING: ...... 50.0 TONS (45.4 METRIC TONS)

INSPECTION DATES

(90) INSPECTION DATE: 8/18 (91) FREQ. OF INSP: 24 MONTHS (92 / 93) CRITICAL FEATURE INSPECTION (CFI):

(219) ADD. STUDIES NEEDED: N - 0 - NONE (A) FRACTURE CRITICAL: ... YES

INSP. EVERY: 24 MONTHS - LAST INSP. : 8/18 (220) SPECIAL STUDY TYPE: 4 - NON-DESTRUCTIVE TESTING

(B) UNDERWATER: .............. NO

(221) SPECIAL STUDY DATE: 9/90 INSP. EVERY: MONTHS - LAST INSP. :

(C) SPECIAL INSPECTION: .. NO

INSP. EVERY: MONTHS - LAST INSP. :

STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 9470-011P

GEOMETRY, TRAFFIC, AND NAVIGATIONAL DATA

(16) LATITUDE: ............................. 48°20'57.00" (51) CURB TO CURB WIDTH: ........... 15.4 FT (4.7 M)

(17) LONGITUDE: ......................... 120°42'50.00" (52) DECK WIDTH: ............................ 20.3 FT (6.2 M)

(19) DETOUR LENGTH: ............... 199 MI (199 KM) (32) APPR. ROADWAY WIDTH: ........ 16.0 FT (4.9 M)

(28A) LANES ON STRUCT: .......... 01 (213) APPR. PAVEMENT WIDTH: ..... 12.0 FT (3.7 M)

(28B) LANES UNDER STRUCT: ... 00 LEFT SHOULDER: .................. 2.0 FT (0.6 M)

(42A) SERVICE ON: ..................... 1 - HIGHWAY RIGHT SHOULDER: ................ 2.0 FT (0.6 M)

(42B) SERVICE UNDER: .............. 5 - WATERWAY (33) BRIDGE MEDIAN: ....................... 0 - NO MEDIAN

(29) AVG. DAILY TRAFFIC: .......... 100 (34) SKEW ANGLE: ............................ 0 °

(30) YEAR OF ADT: ...................... 2010 (35) DECK FLARE?: ........................... NO

(114) FUTURE ADT: ..................... 200 (47) TOTAL HORIZ. CLEARANCE: .... 11.9 FT (3.6 M)

(115) YEAR OF FUTURE ADT: ..... 2030 (50) SIDEWALKS:

(101) PARALLEL STRUCTURE: ... N - NONE LEFT : ...................................... 0.0 FT (0.0 M)

(38) NAVIGATION CONTROL?: ... 0 RIGHT : ................................... 0.0 FT (0.0 M)

(39) VERTICAL CLEARANCE: ...... 0.0 FT (0.0 M) (214) BRIDGE RAIL TYPE:

(40) HORIZ. CLEARANCE: ........... 0.0 FT (0.0 M) RAIL CONFIGURATION: ......... 1 - FULL HEIGHT (NO PARAPE

(111) ABUT. OR PIER PROT: ....... 1 - NAV PROTECTION NOT REQUIRED MATERIAL: .............................. 7 - TIMBER

DESIGN TYPE: ........................ 1 - CONTINUOUS RAIL LATERAL UNDERCLEARANCE:

(55) RIGHT: ....................... 0.0 FT (0.0 M) (215) BRIDGE RAIL HEIGHT: ............ 2.25 FT (0.69 M)

(56) LEFT: ......................... 0.0 FT (0.0 M) (53) MIN. VRT. CLEAR. OVER DECK: 11.00 FT (3.35 M)

(54) MIN. VRT. UNDERCLEARANCE: 0.00 FT (0.00 M)

CONDITION AND APPRAISAL DATA, PROPOSED IMPROVEMENTS, AND COST

(58) DECK:

(59) SUPERSTRUCTURE:

(60) SUBSTRUCTURE:

(61) CHANNEL:

(62) CULVERT: ...........................N

(222) APPROACHES:

(223) RETAINING WALL: ........... N

(36) TRAFFIC SAFETY FEAT: ... 1000

(75A) TYPE OF WORK:

(75B) WORK DONE BY:

(76) IMPROVEMENT LENGTH: ..

(67) STRUCTURAL EVALUATION:

(68) DECK GEOMETRY:

(69) UNDERCLEARANCES:

(71) WATERWAY ADEQUACY:

(72) APPROACH ALIGNMENT:

(113) SCOUR CRITICAL:

(225) PURPOSE OF IMPROVEMENT:

(226) PRIORITY OF IMPROVEMENT:

(227) MAINTENANCE COST:

(228) REHAB./RECONSTR. COST: ...

(229) CONSTRUCTION COST:

N

1 - MAINTENANCE

D - MINOR

$5,000

$0

$0

ADDITIONAL INFORMATION

(230) STRUCTURE HISTORY:

(231) ADDITIONAL CONSIDERATIONS:

(330) ADDITIONAL CONFIG. INFO.:

APPENDIX STRUCTURE NO. 9470-011P

File details come from the government source that posted it. Updated .