Amendment_3_Specification_083613_0003.pdf

PDF 84 KB Posted

Attached to
GAOA - Replace Multipurpose Building, Maintenance Federal contract opportunity
Solicitation number
140FGA24R0003
Issued by
Department of the Interior Fish and Wildlife Service

About this file

This document provides specifications for sectional doors to be installed as part of a construction project to replace a multipurpose building, maintenance shop, cold storage building, and maintenance yard at the Luster Heights National Wildlife Refuge. The project solicitation is issued by the U.S. Fish and Wildlife Service and seeks bids to supply and install sectional doors meeting the specifications provided. Key requirements include steel sectional doors with thermal-break construction and minimum R-value, track and hardware systems, glazed windows, insulated sections, weatherstripping, and electric operators. Door finishes, warranties, and installer qualifications are also specified.

View the file

Other files for this federal contract opportunity

Other files attached to GAOA - Replace Multipurpose Building, Maintenance, newest first.
File Type Posted
Sol_140FGA24R0003_Amd_0003.pdf PDF
Amendment_3_UMR1145A0_Bid_Item_6_Cold_Storage_Building_Floor_Plan_0003.pdf PDF
Amendment_3_Specification_085200_Wood_Windows_0003.pdf PDF
Amendment_3_Drawing_Sheet_A38_Maintenance_Shop_Door_and_Window_Schedules_and_Details_0003.pdf PDF
Amendment_3_Specification_281300_Access_Control_Software_and_Database_Management_0003.pdf PDF
Amendment_3_UMR1148E0_Bid_Item_6_Cold_Storage_Building_Electrical_Plan_0003.pdf PDF
Amendment_3_Drawing_Sheet_A16_Multipurpose_Building_Door_Schedules_and_Details_0003.pdf PDF
Amendment_3_Specification_260519_Low-Voltage_Electrical_Power_Conductors_and_Cables_0003.pdf PDF
Amendment_3_Additional_Project_Information_0003.pdf PDF
Amendment_3_Drawing_Sheet_A17_Multipurpose_Building_Window_Details_0003.pdf PDF
Amendment_3_Drawing_Sheet_A18_Multipurpose_Building_Window_and_Door_Details_0003.pdf PDF
Amendment_3_Specification_095113_Acoustical_Panel_Ceilings_0003.pdf PDF
Amendment_3_Questions_and_Answers_0003.pdf PDF
Amendment_3_Drawing_Sheet_A12_Multipurpose_Building_Wall_Sections_and_Details_0003.pdf PDF
Amendment_3_Drawing_Sheet_A39_Maintenance_Shop_Enlarged_Plans_and_Elevations_0003.pdf PDF
Amendment_3_Drawing_Sheet_L8_Site_Details_0003.pdf PDF
Amendment_3_Drawing_Sheet_A13_Multipurpose_Building_Finish_Plan_0003.pdf PDF
Questions_and_Answers_Amendment_2_0002.pdf PDF
Sol_140FGA24R0003_Amd_0002.pdf PDF
Luster_Heights_Pre-bid_Site_Visit_0002.pdf PDF
Additional_Project_Information_Amendment_2_0002.pdf PDF
Revised_Notice_to_Offerors_0001.pdf PDF
Sol_140FGA24R0003_Amd_0001.pdf PDF
Price_Schedule.pdf PDF
Wage_Determination.pdf PDF
Drawings_Cold_Storage.pdf PDF
Drawings_Luster_Heights.pdf PDF
Sol_140FGA24R0003.pdf PDF
Notice_to_Offerors.pdf PDF
SOW_Luster_Heights_Multiple_Bldgs.pdf PDF
Past_Performance_Questionnaire_(PPQ).pdf PDF
Show all 31

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UPPER MISSISSIPPI RIVER NATIONAL FISH AND WILDLIFE REFUGE USFWSR3_UMRLH

- MCGREGOR DISTRICT

MULTIPURPOSE BUILDING AND MAINTENANCE SHOP

100% CONSTRUCTION DOCUMENT SUBMISSION

LUSTER HEIGHTS, IOWA

3.15.2023

SECTIONAL DOORS 083613 - 1

SECTION 083613 - SECTIONAL DOORS

PART 1 - GENERAL

1.1 RELATED DOCUMENTS

A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.

1.2 SUMMARY

A. Section Includes:

1. Sectional-door assemblies.

B. Related Requirements:

1. Section 099113 "Exterior Painting" Section 099123 "Interior Painting" for finish painting of factory-primed steel doors.

1.3 ACTION SUBMITTALS

A. Product Data: For each type and size of sectional door and accessory.

1. Include construction details, material descriptions, dimensions of individual components, profile door sections, and finishes.

2. For power-operated doors, include rated capacities, operating characteristics, electrical characteristics, and furnished accessories.

B. Shop Drawings: For each installation and for components not dimensioned or detailed in manufacturer's product data.

1. Include plans, elevations, sections, and mounting details.

2. Include details of equipment assemblies. Indicate dimensions, required clearances, method of field assembly, components, and location and size of each field connection.

3. Include points of attachment and their corresponding static and dynamic loads imposed on structure.

4. Include diagrams for power, signal, and control wiring.

C. Samples: For each exposed product and for each color and texture specified, in manufacturer's standard size.

MULTIPURPOSE BUILDING AND MAINTENANCE SHOP

100% CONSTRUCTION DOCUMENT SUBMISSION

LUSTER HEIGHTS, IOWA

SECTIONAL DOORS 083613 - 2

1.4 INFORMATIONAL SUBMITTALS

A. Qualification Data: For Installer.

1.5 CLOSEOUT SUBMITTALS

A. Maintenance Data: For sectional doors to include in maintenance manuals.

B. Manufacturer's warranty.

C. Finish warranty.

1.6 QUALITY ASSURANCE

A. Installer Qualifications: An entity that employs installers and supervisors who are trained and approved by manufacturer for both installation and maintenance of units required for this Project.

1.7 WARRANTY

A. Manufacturer's Warranty: Manufacturer agrees to repair or replace components of sectional doors that fail in materials or workmanship within specified warranty period.

1. Failures include, but are not limited to, the following:

a. Structural failures including, but not limited to, excessive deflection.

b. Failure of components or operators before reaching required number of operation cycles.

c. Faulty operation of hardware.

d. Deterioration of metals, metal finishes, and other materials beyond normal weathering and use; rust through.

e. Delamination of exterior or interior facing materials.

2. Warranty Period: Five years from date of Substantial Completion.

PART 2 - PRODUCTS

2.1 MANUFACTURERS, GENERAL

A. Source Limitations: Obtain sectional doors from single source from single manufacturer.

MULTIPURPOSE BUILDING AND MAINTENANCE SHOP

100% CONSTRUCTION DOCUMENT SUBMISSION

LUSTER HEIGHTS, IOWA

SECTIONAL DOORS 083613 - 3

1. Obtain operators and controls from sectional door manufacturer.

2.2 PERFORMANCE REQUIREMENTS

A. General Performance: Provide sectional doors that comply with performance requirements specified without failure from defective manufacture, fabrication, installation, or other defects in construction.

B. Structural Performance, Exterior Doors: Capable of withstanding the design wind loads.

1. Design Wind Load: As indicated on Drawings.

2. Testing: In accordance with ASTM E330/E330M or DASMA 108 for garage doors and complying with DASMA 108 acceptance criteria.

3. Deflection Limits: Design sectional doors to withstand design wind loads without evidencing permanent deformation or disengagement of door components.

a. Deflection of door sections in horizontal position (open) shall not exceed 1/120 of door width.

b. Deflection of horizontal track assembly shall not exceed 1/240 of door height.

4. Operability under Wind Load: Design sectional doors to remain operable under design wind load, acting inward and outward.

2.3 SECTIONAL-DOOR ASSEMBLY

A. Steel Sectional Door: Provide sectional door formed with hinged sections and fabricated so that finished door assembly is rigid and aligned with tight hairline joints;

free of warp, twist, and deformation; and complies with requirements in DASMA 102.

1. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following:

a. Arm-R-Lite.

b. C.H.I. Overhead Doors, Inc.

c. Clopay Building Products.

d. ENTREMATIC.

e. Fimbel Architectural Door Specialties.

f. Haas Door.

g. Hörmann LLC.

h. Martin Door Manufacturing.

i. Overhead Door Corporation.

j. Raynor.

MULTIPURPOSE BUILDING AND MAINTENANCE SHOP

100% CONSTRUCTION DOCUMENT SUBMISSION

LUSTER HEIGHTS, IOWA

SECTIONAL DOORS 083613 - 4

k. Rite-Hite Corporation.

l. Wayne-Dalton Corp.

m. Windsor Door.

B. Operation Cycles: Door components and operators capable of operating for not less than 25,000 operation cycles. One operation cycle is complete when door is opened from closed position to the open position and returned to closed position.

C. Air Infiltration: Maximum rate of 0.4 cfm/sq. ft. when tested in accordance with ASTM E283 or DASMA 105.

0. U-Value: 0.130 Btu/sq. ft. x h x deg F.

E. Steel Door Sections: ASTM A653/A653M, zinc-coated (galvanized), cold-rolled, commercial steel sheet with G60 zinc coating.

1. Door-Section Thickness: 2 inches.

2. Section Faces:

a. Thermal-Break Construction: Provide sections with continuous thermal-break construction separating the exterior and interior faces of door.

b. Exterior Face: Fabricated from single sheets, not more than 24 inches high;

with horizontal meeting edges rolled to continuous, interlocking, keyed, rabbeted, shiplap, or tongue-in-groove, weather- and pinch-resistant seals and reinforcing flange return.

1) Steel Sheet Thickness: 20 gauge (.040 inch) nominal coated thickness.

2) Surface: Manufacturer's standard, flat.

c. Interior Face: Enclose insulation completely within steel exterior facing and interior facing material, with no exposed insulation. Provide the following interior-facing material:

1) Zinc-Coated (Galvanized) Steel Sheet: With minimum nominal coated thickness of 24 gauge (0.028 inch).

3. End Stiles: Enclose open ends of sections with channel end stiles formed from galvanized-steel sheet not less than 0.064-inch nominal coated thickness and welded to door section.

4. Intermediate Stiles: Provide intermediate stiles formed from not less than 0.040-inch- thick galvanized-steel sheet, cut to door section profile, and welded in place. Space stiles not more than 48 inches apart.

5. Section Reinforcing: Horizontal and diagonal reinforcement as required to stiffen door and for wind loading. Provide galvanized-steel bars, struts, trusses, or strip steel, formed to depth and bolted or welded in place. Ensure that reinforcement does not obstruct vision lites.

MULTIPURPOSE BUILDING AND MAINTENANCE SHOP

100% CONSTRUCTION DOCUMENT SUBMISSION

LUSTER HEIGHTS, IOWA

SECTIONAL DOORS 083613 - 5

a. Bottom Section: Reinforce section with a continuous channel or angle conforming to bottom-section profile and allowing installation of astragal (weatherseal).

b. Hardware Locations: Provide reinforcement for hardware attachment.

6. Thermal Insulation: Insulate interior of steel sections with door manufacturer's standard CFC-free insulation of type indicated below:

a. Board Insulation: Polystyrene, secured to exterior face sheet.

b. Foamed-in-Place Insulation: Polyurethane, foamed in place to completely fill interior of section and pressure bonded to face sheets to prevent delamination under wind load.

c. Fire-Resistance Characteristics: Maximum flame-spread and smoke-developed indexes of 75 and 450, respectively, in accordance with

ASTM E84.

F. Track: Manufacturer's standard, galvanized-steel, standard-lift track system. Provide complete system including brackets, bracing, and reinforcement to ensure rigid support of ball-bearing roller guides.

1. Material: Galvanized steel, ASTM A653/A653M, minimum G60 zinc coating.

2. Size: As recommended in writing by manufacturer for door size, weight, track configuration and door clearances indicated on Drawings.

3. Track Reinforcement and Supports: Provide galvanized-steel members to support track without sag, sway, and vibration during opening and closing of doors. Slot vertical sections of track spaced 2 inches apart for door-drop safety device.

a. Vertical Track: Incline vertical track to ensure weathertight closure at jambs.

Provide continuous angle attached to track and wall.

b. Horizontal Track: Provide continuous reinforcing angle from curve in track to end of track, attached to track and supported at points by laterally braced attachments to overhead structural members.

G. Weatherseals: Replaceable, adjustable, continuous, compressible weather-stripping gaskets of flexible vinyl, rubber, or neoprene fitted to bottom top jambs of door.

H. Windows: Manufacturer's standard window units of shape and size and in locations indicated on Drawings. Set glazing in vinyl, rubber, or neoprene glazing channel.

Provide removable stops of same material as door-section frames. Provide the following glazing:

1. Insulating Glass Units: Manufacturer's standard.

I. Hardware: Heavy-duty, corrosion-resistant hardware, with hot-dip galvanized, stainless steel, or other corrosion-resistant fasteners, to suit door type.

MULTIPURPOSE BUILDING AND MAINTENANCE SHOP

100% CONSTRUCTION DOCUMENT SUBMISSION

LUSTER HEIGHTS, IOWA

SECTIONAL DOORS 083613 - 6

1. Hinges: Heavy-duty, galvanized-steel hinges of not less than 0.079-inch nominal coated thickness at each end stile and at each intermediate stile, in accordance with manufacturer's written recommendations for door size.

a. Attach hinges to door sections through stiles and rails with bolts and lock nuts or lock washers and nuts. Use rivets or self-tapping fasteners where access to nuts is impossible.

b. Provide double-end hinges where required for doors more than 16 ft. wide unless otherwise recommended by door manufacturer in writing.

2. Rollers: Heavy-duty rollers with steel ball bearings in case-hardened steel races, mounted to suit slope of track. Extend roller shaft through both hinges where double hinges are required. Match roller-tire diameter to track width.

3. Push/Pull Handles: Equip each door with galvanized-steel lifting handles on each side of door, finished to match door.

J. Locking Device:

1. Slide Bolt: Fabricate with side-locking bolts to engage through slots in tracks for locking by padlock, located on single-jamb side, operable from inside only.

2. Locking Device Assembly: Fabricate with cylinder lock, spring-loaded deadbolt, operating handle, cam plate, and adjustable locking bars to engage through slots in tracks.

a. Lock Cylinders: Cylinders complying with Section 087111 "Door Hardware (Descriptive Specification)" requirements.

b. Keying: Keyed to building keying system.

K. Counterbalance Mechanism:

1. Torsion Spring: Adjustable-tension torsion springs complying with requirements of DASMA 102 for number of operation cycles indicated, mounted on torsion shaft.

2. Cable Drums and Shaft for Doors: Cast-aluminum cable drums mounted on torsion shaft and grooved to receive door-lifting cables as door is raised.

a. Mount counterbalance mechanism with manufacturer's standard ball-bearing brackets at each end of torsion shaft.

b. Provide one additional midpoint bracket for shafts up to 16 ft. long and two additional brackets at one-third points to support shafts more than 16 ft.

long unless closer spacing is recommended in writing by door manufacturer.

3. Cable Safety Device: Include a spring-loaded steel or bronze cam mounted to bottom door roller assembly on each side and designed to automatically stop door if lifting cable breaks.

MULTIPURPOSE BUILDING AND MAINTENANCE SHOP

100% CONSTRUCTION DOCUMENT SUBMISSION

LUSTER HEIGHTS, IOWA

SECTIONAL DOORS 083613 - 7

4. Bracket: Provide anchor support bracket as required to connect stationary end of spring to the wall and to level the shaft and prevent sag.

5. Bumper: Provide spring bumper at each horizontal track to cushion door at end of opening operation.

L. Electric Door Operator: Electric door operator assembly of size and capacity recommended by door manufacturer for door and operation cycles specified, with electric motor and factory-prewired motor controls, starter, gear-reduction unit, solenoid-operated brake, clutch, control stations, control devices, integral gearing for locking door, and accessories required for proper operation.

1. Comply with NFPA 70.

2. Control equipment complying with NEMA ICS 1, NEMA ICS 2, and NEMA ICS 6;

with NFPA 70, Class 2 control circuit, maximum 24 V ac or dc.

3. Safety: Listed in accordance with UL 325 by a qualified testing agency for commercial or industrial use; moving parts of operator enclosed or guarded if exposed and mounted at 8 ft. or lower.

4. Usage Classification: Standard duty, up to 25 cycles per hour and up to 90 cycles per day.

5. Operator Type: Manufacturer's standard for door requirements.

6. Motor: Reversible-type with controller (disconnect switch) for interior, clean, and dry motor exposure. Use adjustable motor-mounting bases for belt-driven operators.

a. Motor Size: As required to start, accelerate, and operate door in either direction from any position, at a speed not less than 8 in./sec. and not more than 12 in./sec., without exceeding nameplate ratings or service factor.

b. Electrical Characteristics:

1) Phase: Single phase.

2) Volts: 115 V.

7. Limit Switches: Equip motorized door with adjustable switches interlocked with motor controls and set to automatically stop door at fully opened and fully closed positions.

8. Obstruction Detection: Automatic external entrapment protection consisting of automatic safety sensor capable of protecting full width of door opening.

Activation of device immediately stops and reverses downward door travel.

a. Monitored Entrapment Protection: Photoelectric sensor designed to interface with door-operator control circuit to detect damage to or disconnection of sensor and complying with requirements in UL 325.

9. Control Station: Surface mounted, two-position (open and close) control.

a. Operation: Push button.

b. Interior-Mounted Unit: Full-guarded, surface-mounted, standard-duty, weatherproof-type, NEMA ICS 6, Type 4 enclosure.

MULTIPURPOSE BUILDING AND MAINTENANCE SHOP

100% CONSTRUCTION DOCUMENT SUBMISSION

LUSTER HEIGHTS, IOWA

SECTIONAL DOORS 083613 - 8

c. Features: Provide the following:

2) Radio-control operation.

4) Photocell operation.

10. Emergency Manual Operation: Push-up type designed so required force for door operation does not exceed 25 lbf.

11. Emergency Operation Disconnect Device: Hand-operated disconnect mechanism for automatically engaging manual operator and releasing brake for emergency manual operation while disconnecting motor without affecting timing of limit switch. Mount mechanism so it is accessible from floor level. Include interlock device to automatically prevent motor from operating when emergency operator is engaged.

12. Motor Removal: Design operator so motor can be removed without disturbing limit-switch adjustment and without affecting emergency manual operation.

M. Metal Finish: Comply with NAAMM/NOMMA's "Metal Finishes Manual for Architectural and Metal Products (AMP 500-06)" for recommendations for applying and designating finishes.

1. Factory Prime Steel Finish: Compatible with field-applied finish and in manufacturer's standard color. Comply with coating manufacturer's written instructions for cleaning, pretreatment, application, and minimum dry film thickness.

2. Exterior Finish: Factory finished with acrylic baked enamel, color as selected by Government from manufacturer’s standard colors.

3. Interior Finish: Factory finished with acrylic baked enamel, manufacturer’s standard white color.

PART 3 - EXECUTION

3.1 EXAMINATION

A. Examine substrates, areas, and conditions, with Installer present, for compliance with requirements for substrate construction and other conditions affecting performance of the Work.

B. Proceed with installation only after unsatisfactory conditions have been corrected.

3.2 INSTALLATION

A. Install sectional doors and operating equipment complete with necessary hardware, anchors, inserts, hangers, and equipment supports; in accordance with manufacturer's written instructions.

MULTIPURPOSE BUILDING AND MAINTENANCE SHOP

100% CONSTRUCTION DOCUMENT SUBMISSION

LUSTER HEIGHTS, IOWA

SECTIONAL DOORS 083613 - 9

B. Tracks:

1. Fasten vertical track assembly to opening jambs and framing with fasteners spaced not more than 24 inches apart.

2. Hang horizontal track assembly from structural overhead framing with angles or channel hangers attached to framing by welding or bolting, or both. Provide sway bracing, diagonal bracing, and reinforcement as required for rigid installation of track and door-operating equipment.

C. Accessibility: Install sectional doors, switches, and controls along accessible routes in compliance with regulatory requirements for accessibility.

D. Power-Operated Doors: Install automatic garage doors openers in accordance with

UL 325.

3.3 STARTUP SERVICES

A. Engage a factory-authorized service representative to perform startup service.

1. Complete installation and startup checks in accordance with manufacturer's written instructions.

2. Test and adjust controls and safety devices. Replace damaged and malfunctioning controls and equipment.

3.4 ADJUSTING

A. Adjust hardware and moving parts to function smoothly so that doors operate easily, free of warp, twist, or distortion.

B. Lubricate bearings and sliding parts as recommended by manufacturer.

C. Adjust doors and seals to provide weather-resistant fit around entire perimeter.

D. Touchup Painting Galvanized Material: Immediately after welding galvanized materials, clean welds and abraded galvanized surfaces and repair galvanizing to comply with

ASTM A780/A780M.

END OF SECTION 083613