This document contains construction drawings and details for a multipurpose building project. The drawings specify wood framed windows with aluminum cladding on the exterior to be installed according to glazing Specification 085200. All operable window portions will include insect screens. Window types include awning, fixed, and storefront aluminum frames. Door and window details provide dimensions and notes for installation of frames, glazing, weather barriers, caulking, and finishes.
The related federal contract opportunity is a solicitation from the U.S. Fish and Wildlife Service to replace the multipurpose building, maintenance shop, cold storage building, and maintenance yard at the Luster Heights National Wildlife Refuge. Solicitation number 140FGA24R0003 has a description of replacing the structures and yard.
View the file
Other files for this federal contract opportunity
Show all 31
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WOOD FRAMED WINDOWS W/ ALUMINUM CLAD EXTERIOR
F.F.
SEE SPECIFICATION 085200 - GLAZING FOR THESE WINDOWS IS TO BE PER SPECIFICATION 085200
*ALL OPERABLE WINDOW PORTIONS TO RECEIVE INSECT SCREENS
AWNING WINDOW FIXED WINDOW
5'-0"
WA WDINTERIOR SILL TO BE WOOD
AWNING WINDOW
5'-0"
WB
AWNING WINDOW
3'-0"
WC
S E E
E L E V A T
IO
N
OPERABLE
AWNING
PORTION
A18
_______________ 1
A18
A18
A18
A18
A18
A18
A18
A18
A18
A18
A18
6'-0"
OPERABLE
AWNING
PORTION
STOREFRONT ALUMINUM FRAME TYPES
F.F.
SA SB SC
SEE SPECIFICATION 084113
**INTERIOR WINDOW
B,C B,C B,C B,C
-0
-0
A,C A,C A,C
A,C A,C
A,C
A L
IG
N
T Y P
A17
A18
A18
SIM
A18
A18
SIM
A,C
9'-11 3/4"
2"
1'-6 7/8"
2"
3'-0"
2"
3'-0"
2"
1'-6 7/8"
2"
45.00°
A,C A,C
B,C B,C B,CB,C
A,C
-0
9'-11 3/4"
2"
1'-7"
2"
3'-0"
2"
3'-0"
2"
1'-7"
2"
" 2
A17
A17
-0
45.00°
D
DD
D
D
DD D
DD D
DD D
D D
D
D
A L
IG
N
T Y P
SIM
B,C B,C B,C
B,C
A,C
A,C A,C A,C
-0
A18
SIM
A18
_______________9
A17
A18
SIM
2"3'-7"
2"
3'-0"
2"
3'-0"
2"
3'-7"2"
14'-0"
-0
45.00°
A,C
A,C A,C A,CA,C
A,C A,CA,C
A L
IG
N
T Y P
WALL PER PLAN
SEALANT, EA SIDE
HM FRAME PER SCHED.
DOOR PER SCHED.
DOOR SILENCERS
WALL PER PLAN
SEALANT, EA SIDE
HM FRAME PER SCHED.
DOOR PER SCHED.
DOOR SILENCERS
FINISH TRANSITION TO OCCUR
UNDER DOOR
DOOR PER SCHED.
FINISH FLOOR PER
PLAN
CONCRETE SLAB SEE
STRUCTURAL DRAWINGS
WALL PER PLAN
SEALANT, EA SIDE
INTERIOR ALUMINUM
FRAMED WINDOW
**SIMILAR DETAIL AT JAMB OF WINDOW
GLAZING PER SCHEDULE
DOOR THRESHOLD SET IN FULL
BED OF SEALANT
DOOR PER SCHED.
FINISH FLOOR PER PLAN
CONCRETE SLAB SEE STRUCTURAL
WALL BEYOND
FOUNDATION INSULATION
WALL PER PLAN
WINDOW PER SCHED.
SEALANT EACH SIDE
A. INSULATED GLAZING UNIT
B. INSULATED FULLY TEMPERED GLAZING UNIT
C. GLAZING TO BE BIRD CONTROL GLASS GLAZING,
SEE SPECIFICATIONS
D. FULLY TEMPERED GLASS
GLAZING TYPES
SEE NOTES ON ALUMINUM
FRAMING TYPES
I.E. IF NOTE READS "A,D"
BOTH GLAZING TYPES APPLY
PREFINISHED
METAL FLASHING
FIBER CEMENT
TRIM BOARD, PAINT
PREFINISHED
METAL FLASHING
INSULATED HOLLOW
METAL FRAME - FILL
FRAME AND SHIM
SPACE WITH SPRAY
FOAM INSULATION
LAP SIDING Z
FURRING STARTER
LAP BUILDING WRAP
FLASHING OVER METAL
FLASHING, TYPICAL
INTERIOR EXTERIOR
BLOCKING AS
REQUIRED
WRAP WINDOW OPENING PER
WEATHER BARRIER WRITTEN
RECOMMENDATIONS AND
INSTRUCTIONS
VAPOR BARRIER, RUN DOWN
ENTIRETY OF WALL AND
WRAP INTO WINDOW
OPENING
JOINT SEALANT/
BACKING (EACH SIDE)
DOOR AS SCHEDULE
WALL BEYOUND
GYPSUM BOARD
CORNER BEAD
FIBER CEMENT
TRIM BOARD, PAINT
JOINT SEALANT/
BACKING (EACH SIDE) CAULK JOINT PER
MANUFACTURER
RECOMMENDATION
BLOCKING AS REQUIRED
INTERIOR
EXTERIOR
WRAP WINDOW OPENING PER
WEATHER BARRIER WRITTEN
RECOMMENDATIONS AND
INSTRUCTIONS
VAPOR BARRIER, RUN
DOWN ENTIRETY OF WALL
AND WRAP INTO WINDOW
OPENING
WOOD JAMB EXTENSION
ASSOCIATED WITH
WINDOW - SEE
SPECIFICATION 085200
INSULATED HOLLOW
METAL FRAME FILL
FRAME AND SHIM
SPACE WITH SPRAY
FOAM INSULATION
DOOR AS SCHEDULE
WALL BEYOUND
SEALANT
GYPSUM BOARD
CORNER BEAD
SHEET OF
ORIGINAL DRAWING
NOT ONE INCH
ON THIS SHEET
ACCORDINGLY, IF
ADJUST SCALES
0"
ONE INCH ON
THIS BAR IS
VERIFY SCALE
CHECKED:
REV.
DESIGNED: DRAWN:
DATE
DRAWING NO:
DATE:
DESCRIPTION BY
1"
3R-IA-93-CADD:UMR
MULTIPURPOSE BUILDING AND
MAINTENANCE SHOPALLAMAKEE COUNTY LUSTER HEIGHTS, IOWA
PROJECT NUMBER: 21-RF-015
TDF
MULTIPURPOSE BUILDING WINDOW ELEVATIONS
SB PSM 03.15.2023
A17
611045A4
A17
2 TYPICAL INTERIOR HM DOOR HEAD
A17
6 TYPICAL INTERIOR HM DOOR JAMB
A17
7 TYPICAL INTERIOR HM DOOR SILL
A17
8 TYPICAL INTERIOR ALUM. FRAMED WINDOW HEAD
A17
9 TYPICAL EXTERIOR STOREFRONT DOOR SILL
A17
10 TYPICAL INTERIOR HM WINDOW JAMB
SCALE IN FEET
SCALE: 1 1/2" = 1'-0"
SCALE IN FEET
SCALE: 1 1/2" = 1'-0"
SCALE IN FEET
SCALE: 1 1/2" = 1'-0"
SCALE IN FEET
SCALE: 1 1/2" = 1'-0"
SCALE IN FEET
SCALE: 1 1/2" = 1'-0"
SCALE IN FEET
SCALE: 1 1/2" = 1'-0"
A17
11 EXT HM HEAD AT FIBER CEMENT SIDING
10.50
SCALE IN FEET
SCALE: 3" = 1'-0"
A17
12 EXT HM JAMB AT FIBER CEMENT SIDING
10.50
SCALE IN FEET
SCALE: 3" = 1'-0"
4.18.2023
| Sheets |
| A16 - MULTIPURPOSE BUILDING DOOR SCHEDULES AND DETAILS |
| A17 - MULTIPURPOSE BUILDING WINDOW ELEVATIONS |
| A18 - MULTIPURPOSE BUILDING WINDOW AND DOOR DETAILS |
File details come from the government source that posted it. Updated .