FY21DD Propulsion Motor Room Tank Top Plating.pdf

PDF 159 KB Posted

Attached to
NOAA SHIP OKEANOS EXPLORER FY26 DRYDOCK REPAIR
Solicitation number
1305M225Q0151
Issued by

About this file

This document is a Nondestructive & Visual Inspection Report for the R/V Okeanos Explorer, specifically focusing on thickness measurements of the tank top plating in the IWO Propulsion Motor Room. The survey was conducted on 11/16/20 by NVI, LLC., with technician Jonathan Rosales performing the inspection. The report provides detailed measurements of the structural member, including original thickness (0.375 inches), maximum allowable diminution percentages (25%), and actual gauged diminution values for both port and starboard sides.

The plan view diagram highlights areas of substantial and excessive wastage, with orange indicating substantial wastage and red marking excessive wastage. The measurement points range from 1-57, with varying levels of material degradation. The most significant diminution percentages range from 0.3% to 41.3%, with some areas showing more extensive material loss. The report is part of a larger assessment for the NOAA Ship Okeanos Explorer FY26 Drydock Repair, suggesting this inspection is preparatory to potential maintenance or repair work on the vessel's propulsion motor room tank top plating.

View the file

Other files

File Type Posted
Sol_1305M225Q0151_Amd_0006.pdf PDF
FY21DD RV OKEANOS EXPLORER - SIGNED (2).pdf PDF
Sol_1305M225Q0151_Amd_0008.pdf PDF
Sol_1305M225Q0151_Amd_0003.pdf PDF
Attachment 1 (Updated) - NOAA Ship Okeanos Explorer FY 2026 Drydock Repair Specifications Revision 2.pdf PDF
Drawing 320-6233696_HVAC Elementary and Isometric Wiring Diagram.pdf PDF
FY21DD Lower Engine Room Deck.pdf PDF
528-6233903.pdf PDF
Lifting Appliance Certifications NOAA Ship Okeanos Explorer DS FY25.pdf PDF
Drawing 512-6233797_HVAC Lower Platform.pdf PDF
NOAA Standard Specification AMC-300-1_Overhaul of Electrical Rotating Machinery.pdf PDF
NVIC 3-97 Stability Related Review Performed by the American Bureau of Shipping for U.S. Flag Vessels.pdf PDF
OE-085-001.pdf PDF
Sol_1305M225Q0151_Amd_0005.pdf PDF
Drawing 512-6233792_ Heating Ventilation and Air Conditioning Diagram.pdf PDF
Maintenance Item Details Port ROV and STBD Working Cranes (1).pdf PDF
USCG MSC Plan Review Guideline GEN-02 Submission of Stability Test (Deadweight Survey or Inclining Experiment).pdf PDF
620-6233557.pdf PDF
CFR-023 WI-573-01 NOAA Ship Okeanos Explorer DS FY25.pdf PDF
Attachment I - LIST OF REFERENCES-Okeanos Explorer.xlsx XLSX spreadsheet
620-6233548.pdf PDF
NOAA Standard Specification AMC-583-1B General Requirements for Life Raft Inspections.pdf PDF
Sol_1305M225Q0151_Amd_0007.pdf PDF
Sol_1305M225Q0151_Amd_0009.pdf PDF
OE-165-101.pdf PDF
Anchor Windlass and Capstan Manual (1).pdf PDF
243-6233870 (1).pdf PDF
Sol_1305M225Q0151_Amd_0004.pdf PDF
110-6233551.pdf PDF
512-6233792 (1).pdf PDF
OE-165-101_.pdf PDF
Attachment 2 - Price Schedule Okeanos Explorer.xlsx XLSX spreadsheet
Attachment 7 Subcontracting Plan Template.pdf PDF
Sol_1305M225Q0151_Amd_0002.pdf PDF
Sol_1305M225Q0151_Amd_0001.pdf PDF
Attachment 1 - NOAA Ship Okeanos Explorer FY 2026 Drydock Repair Specifications Revision 1.pdf PDF
Show all 36

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Date Of Survey:

Vessel Name:

STRUCTURAL MEMBER:

LOCATION OF STRUCTURE

Org. Org.

Thk. Thk.

In In % Port Stbd In % In % In In % Port Stbd In % In % TANK TOP PLATE 1 0.375 0.094 25% 0.218 0.220 0.157 41.9 0.155 41.3 TANK TOP PL CONT 33 0.375 0.094 25% 0.370 0.365 0.005 1.3 0.010 2.7

2 0.375 0.094 25% 0.362 0.213 0.013 3.5 0.162 43.2 34 0.375 0.094 25% 0.368 0.370 0.007 1.9 0.005 1.3 3 0.375 0.094 25% 0.243 0.251 0.132 35.2 0.124 33.1 35 0.375 0.094 25% 0.368 0.366 0.007 1.9 0.009 2.4 4 0.375 0.094 25% 0.266 0.109 29.1 36 0.375 0.094 25% 0.371 0.362 0.004 1.1 0.013 3.5 5 0.375 0.094 25% 0.373 0.220 0.002 0.5 0.155 41.3 37 0.375 0.094 25% 0.382 0.341 0.034 9.1 6 0.375 0.094 25% 0.380 0.334 0.041 10.9 38 0.375 0.094 25% 0.401 0.326 0.049 13.1 7 0.375 0.094 25% 0.366 0.374 0.009 2.4 0.001 0.3 39 0.375 0.094 25% 0.330 0.045 12.0 8 0.375 0.094 25% 0.368 0.007 1.9 40 0.375 0.094 25% 0.361 0.014 3.7 9 0.375 0.094 25% 0.372 0.003 0.8 41 0.375 0.094 25% 0.345 0.030 8.0 10 0.375 0.094 25% 0.359 0.362 0.016 4.3 0.013 3.5 42 0.375 0.094 25% 0.383 0.347 0.028 7.5 11 0.375 0.094 25% 0.368 0.216 0.007 1.9 0.159 42.4 43 0.375 0.094 25% 0.374 0.001 0.3 12 0.375 0.094 25% 0.366 0.369 0.009 2.4 0.006 1.6 44 0.375 0.094 25% 0.270 0.105 28.0 13 0.375 0.094 25% 0.209 0.166 44.3 45 0.375 0.094 25% 0.263 0.112 29.9 14 0.375 0.094 25% 0.241 0.134 35.7 46 0.375 0.094 25% 0.271 0.104 27.7 15 0.375 0.094 25% 0.240 0.135 36.0 47 0.375 0.094 25% 0.370 0.005 1.3 16 0.375 0.094 25% 0.232 0.143 38.1 48 0.375 0.094 25% 0.364 0.011 2.9 17 0.375 0.094 25% 0.267 0.108 28.8 49 0.375 0.094 25% 0.369 0.346 0.006 1.6 0.029 7.7 18 0.375 0.094 25% 0.241 0.134 35.7 50 0.375 0.094 25% 0.376 0.344 0.031 8.3 19 0.375 0.094 25% 0.220 0.155 41.3 51 0.375 0.094 25% 0.341 0.034 9.1 20 0.375 0.094 25% 0.236 0.139 37.1 52 0.375 0.094 25% 0.360 0.337 0.015 4.0 0.038 10.1 21 0.375 0.094 25% 0.374 0.368 0.001 0.3 0.007 1.9 53 0.375 0.094 25% 0.348 0.027 7.2 22 0.375 0.094 25% 0.381 0.366 0.009 2.4 54 0.375 0.094 25% 0.354 0.021 5.6 23 0.375 0.094 25% 0.345 0.346 0.030 8.0 0.029 7.7 55 0.375 0.094 25% 0.346 0.029 7.7 24 0.375 0.094 25% 0.338 0.350 0.037 9.9 0.025 6.7 56 0.375 0.094 25% 0.345 0.352 0.030 8.0 0.023 6.1 25 0.375 0.094 25% 0.349 0.353 0.026 6.9 0.022 5.9 57 0.375 0.094 25% 0.360 0.366 0.015 4.0 0.009 2.4 26 0.375 0.094 25% 0.347 0.028 7.5 27 0.375 0.094 25% 0.356 0.346 0.019 5.1 0.029 7.7 28 0.375 0.094 25% 0.338 0.037 9.9 29 0.375 0.094 25% 0.354 0.358 0.021 5.6 0.017 4.5 30 0.375 0.094 25% 0.351 0.024 6.4 31 0.375 0.094 25% 0.362 0.351 0.013 3.5 0.024 6.4 32 0.375 0.094 25% 0.346 0.346 0.029 7.7 0.029 7.7

Technician JONATHAN ROSALES, ASNT II NVI, LLC. ABS Cert. No. 18-HOM-3583568-A COUNT:

Operator's Signature ABS Surveyor's Signature

NONDESTRUCTIVE & VISUAL INSPECTION, LLC.

11/16/20 VT MARINE PAGE 1 OF 1

Report on THICKNESS MEASUREMENTS

R/V OKEANOS EXPLORER Class Identity No. IMO: 8835114; L 224' X B 43' X DR 17' Report No. UT-321-0500

TANK TOP PLATING

IWO PROPULSION MOTOR ROOM, SUSPECT AREA

Maximum Maximum Allowable Gauged Diminution Diminution Allowable Gauged Diminution Diminution

DESCRIPTION Diminution Port Stbd DESCRIPTION

Diminution Port Stbd

File details come from the government source that posted it. Updated .