This document provides information regarding a future solicitation for the Renovation of Catalina Headquarters at El Yunque National Forest in Puerto Rico. The project involves reconstructing the 11,016 square foot, two-story Catalina Headquarters Building and site based on construction documents dated June 22, 2020. The building previously housed the El Yunque National Forest Supervisors Office. It sustained damage from Hurricanes Irma and Maria in 2017. The selected contractor will furnish all labor, materials, equipment, tools, transportation, supervision, facilities, and supplies to complete the project. The North American Industry Classification System code is 236220 for commercial and institutional building construction. The estimated value of the solicitation is between $4 million and $10 million. All vendors must register in sam.gov to be eligible for award. The solicitation is expected to be issued on or around July 15, 2020 and will include the scope of work and any amendments. Further details will be provided in the future solicitation available on the Federal Business Opportunities website.
View the file
Other files
Show all 35
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
(x)
1243ZP20R0011
x x
1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted ; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGEMENT TO BE
RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR
OFFER. If by virtue of this amendment you desire to change an offer already submitted , such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
x
43ZP
ATLANTA GA 30309-2449
1720 PEACHTREE RD SW SUITE 876 SOU
SOUTHERN REGION
USDA FOREST SERVICE
08/31/20200003
13. THIS ITEM ONLY APPLIES TO MODIFICATION OF CONTRACTS/ORDERS. IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
12. ACCOUNTING AND APPROPRIATION DATA (If required) is not extended.is extended, Items 8 and 15, and returning
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended , by one of the following methods: (a) By completing
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
FACILITY CODE CODE
10B. DATED (SEE ITEM 13)
10A. MODIFICATION OF CONTRACT/ORDER NO.
9B. DATED (SEE ITEM 11)
9A. AMENDMENT OF SOLICITATION NO.
CODE
8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code)
7. ADMINISTERED BY (If other than Item 6)CODE 6. ISSUED BY
PAGE OF PAGES
4. REQUISITION/PURCHASE REQ. NO.3. EFFECTIVE DATE2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO. (If applicable)
1. CONTRACT ID CODE
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
07/20/2020
CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority) appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
E. IMPORTANT: Contractor is not is required to sign this document and return ________1_________ copies to the issuing office.
ORDER NO. IN ITEM 10A.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
Amendment 0003
The purpose of this amendment is to post the Q&As and to incorporate a corrected SF-1442.
The Original SF-1442 incorrectly selected that bid guarantees was not required. The corrected SF-1442 checks that bid guarantee is required for this solicitation.
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)15A. NAME AND TITLE OF SIGNER (Type or print)
15C. DATE SIGNED 16B. UNITED STATES OF AMERICA 15B. CONTRACTOR/OFFEROR 16C. DATE SIGNED
(Signature of person authorized to sign) (Signature of Contracting Officer)
SHUNDRICA T. DANIELS
STANDARD FORM 30 (REV. 11/2016)
Prescribed by GSA FAR (48 CFR) 53.243
Previous edition unusable
Except as provided herein, all terms and conditions of the document referenced in Item 9 A or 10A, as heretofore changed, remains unchanged and in full force and effect .
X
08/31/2020
SOLICITATION, OFFER,
AND AWARD
2. TYPE OF SOLICITATION
6. PROJECT NO. 4. CONTRACT NO. 5. REQUISITION/PURCHASE REQUEST NO.
PAGE OF PAGES
7. ISSUED BY CODE 8. ADDRESS OFFER TO
SOLICITATION
(Construction, Alteration, or Repair)
1. SOLICITATION NO. 3. DATE ISSUED
IMPORTANT -- The "offer" section on the reverse must be fully completed by offeror.
9.
INFORMATION
NOTE: In sealed bid solicitations "offer" and "offeror" mean "bid" and "bidder."
CALL:
FOR
SEALED BID (IFB)
NEGOTIATED (RFP)
1009707
USDA FOREST SERVICE
SOUTHERN REGION
1720 PEACHTREE RD SW SUITE 876 SOU
ATLANTA GA 30309-2449
43ZP
a. NAME
SHUNDRICA DANIELS
b. TELEPHONE NO. (Include area code) (NO COLLECT CALLS)
404-347-2348
2 x 07/20/2020
1243ZP20R0011
10. THE GOVERNMENT REQUIRES PERFORMANCE OF THE WORK DESCRIBED IN THESE DOCUMENTS (Title, identifying no., date)
11. The Contractor shall begin performance
12a. THE CONTRACTOR MUST FURNISH ANY REQUIRED PERFORMANCE AND PAYMENT BONDS?
award, notice to proceed. The performance period is mandatory negotiable. (See ________________________________________________.)
13. ADDITIONAL SOLICITATION REQUIREMENTS:
a. Sealed offers in original and is not required.is, b. An offer guarantee
c. All offers are subject to the (1) work requirements, and (2) other provisions and clauses incorporated in the solicitation in full text or by reference.
(date). If this is a sealed bid solicitation, offers will be publicly opened at that time. Sealed envelopes containing offers shall be marked to show the offeror's name and address, the solicitation number, and the date and time offers are due.
d. Offers providing less than
12b. CALENDAR DAYSYES NO
(If "YES", indicate within how many calendar days after award in Item 12b.)
0 0 calendar days and complete it within ________________ ________________ calendar days after receiving
____09/11/2020
NSN 7540-01-155-3212
x x copies to perform the work required are due at the place specified in Item 8 by _____________ ____1600____ (hour) local time calendar days for Government acceptance after the date offers are due will not be considered and will be rejected . _________________
STANDARD FORM 1442 (Rev. 4-85)
Prescribed by GSA
FAR(48 CFR) 53.236-1(d)
X
X
Price Range: The Government's estimate is between $5,000,000 and $10,000,000.
BONDS: Payment and Performance Bonds are required for the Awardee. A Bid Guarantee is required. Electronic bonds shall be sent per FAR CAAC Letter # 2020-04.
17. The offeror agrees to perform the work required at the prices specified below in strict accordance with the terms of this solicitation, if this offer is accepted by the Government in writing within ____________________ calendar days after the date offers are due. (Insert any number equal to or greater than the minimum requirement stated in item 13d. Failure to insert any number means the offeror accepts the minimum in item 13d.)
14. NAME AND ADDRESS OF OFFEROR (Include ZIP Code) 15. TELEPHONE NO. (Include area code)
16. REMITTANCE ADDRESS (Include only if different than item 14.)
CODE FACILITY CODE
AMOUNTS
18. The offeror agrees to furnish any required performance and payment bonds.
19. ACKNOWLEDGEMENT OF AMENDMENTS
OFFER (Must be fully completed by offeror)
(The offeror acknowledges receipt of amendments to the solicitation -- give number and date of each)
AMENDMENT NO.
DATE.
20a. NAME AND TITLE OF PERSON AUTHORIZED TO SIGN OFFER (Type or print) 20b. SIGNATURE 20c. OFFER DATE
AWARD (To be completed by Government)
21. ITEMS ACCEPTED:
22. AMOUNT 23. ACCOUNTING AND APPROPRIATION DATA
24. SUBMIT INVOICES TO ADDRESS SHOWN IN
(4 copies unless otherwise specified)
ITEM 25. OTHER THAN FULL AND OPEN COMPETITION PURSUANT TO
26. ADMINISTERED BY CODE 27. PAYMENT WILL BE MADE BY
CONTRACTING OFFICER WILL COMPLETE ITEM 28 OR 29 AS APPLICABLE
(Contractor is required to sign this document and return (Contractor is not required to sign this document.)
Your offer on this solicitation is hereby accepted as to the items listed. This award consummates the contract, which consists of (a) the Government solicitation and your offer, and (b) this contract award.
No further contractual document is necessary.
30a. NAME AND TITLE OF CONTRACTOR OR PERSON AUTHORIZED TO SIGN (Type or print) 31a. NAME OF CONTRACTING OFFICER (Type or print)
30b. SIGNATURE 30c. DATE 31b. UNITED STATES OF AMERICA 31c. DATE
BY
PAGE 3 OF
USDA FOREST SERVICE
SOUTHERN REGION
1720 PEACHTREE RD SW SUITE 876 SOU
ATLANTA GA 30309-2449
43ZP
SHUNDRICA T. DANIELS
28. NEGOTIATED AGREEMENT 29. AWARD
Contractor agrees to furnish and deliver all items or perform all work requirements identified on this form and any continuation sheets for the consideration stated in this contract. The rights and obligations of the parties to this contract shall be governed by (a) this contract award, (b) the solicitation, and (c) the clauses, representations, copies to issuing office.)
10 U.S.C. 2304(c) 41 U.S.C. 253(c)
STANDARD FORM 1442 (REV. 4-85) BACK
Continued...
08/31/2020
Item # Question Response
1 Is there a Site Visit? Site Showing by appointment for 8/19-21/2020 from 8:30am-12pm posted on beta.Sam.gov to be scheduled through Eventbrite.
2 Unable to download one of the attachment documents provided today at the project solicitation page: Catalina Revitalization SOW_17Jul20.pdf.
An Amendment was issued 07/20/2020 that includes the requested information.
3 The following document is not available for download via beta.Sam.gov: Catalina
Revitalization SOW_17Jul20.pdf.
See Item #2.
4 We do not see information uploaded on the Beta Sam page of plans and request for SOW.
Documentation for the visiting site or solicitation.
See Items #1 and #2.
5 I was unable to locate any document within the system that provides information as to how to participate in the id process and if there is any scheduled site visit to participate in.
See Items #1 and #2.
6 Please specify Ceramic Tiles (CT) in the "Interior Finish Schedule" in page A-600 of the drawings. Most appear as "CT" without number detail.
For Accents/Walls, use CT1/CT2. For Floors/Base, use CT3. For Shower Walls, use CT4. Colors to be confirmed from BOD manufacturer's standard color sections (via submittal) during construction phase.
7 Please confirm Kitchen Backsplash as CT-2. This is specified as 12" x 24" not typical size for backsplash.
Price as indicated. Selection will be confirmed (via submittal) during construction phase.
8 Allowed to submit alternates for materials? No. Submit materials as specified. If a trade name is specified as a Basis of Design (BOD),it should be understood as “similar or equal” to such brand.
9 Is there be a millwork schedule for the furniture? Panel type for millwork? Hardware? ADA accessible?
Systems furniture is provided by the Government. This facility is to be 100% accessible. All available information for millwork/hardware is in drawings/specifications. Provide a suitable allowance for any unclear items.
10 Will the same 600A main breaker be used, the existing one? All equipment to be new, unless indicated as Existing to be Reused (See E-501).
11 Will the electrical panels be new? All equipment to be new, unless indicated as Existing to be Reused (See E-501).
11 Will the pipe that goes from the main breaker to the transformer be reused or is it new? All equipment to be new, unless indicated as Existing to be Reused (See E-501).
12 Are the lighting posts new or are they existing? All equipment to be new, unless indicated as Existing to be Reused (See E-501).
13 On page A-501, where does the Type E door apply? Unknown at this time. Provide pricing per drawings/specifications. Door Type E will be clarified during construction.
14 In Division 7 of the specifications, where does Section 072700 apply? See Architectural Drawings.
15 In Division 10, where does Section 104413 apply? See Architectural Drawings.
16 On pages A-001, note J, please provide name of existing sealing company. Existing roof manufacturer is All Weather Insulated Panels. Product and Warranty information have been added to the Solicitation.
17 On page C-101, key note 2, indicates demolition of building 2, please provide photos and dimensions.
See Item #1.
18 Please indicate if there will be a site visit. See Item #1.
19 On page C-102, indicate "future solar canopy", please clarify if this is part of the work; if so, please provide drawings and specifications.
OPTION ITEM NO. 1 - Solar Installation has been deleted from this Solicitation.
20 There are 3 types of readers listed in the spec (HID models 920PHRNEK00004, 910PHRNEK00004 & 921PHRNEK0002D) but nothing identifies then in the print. Can you indicate the reader(s) to be used, and the location for each?
See Section 087100: 3.9 Door Hardware Schedule.
21 Access Controller are to be installed where? Install in IT Room.
22 Door Hardware: Maglocks, strikes, electrified locks, or mechanical/electromechanical push bars-which are to be used? If so, what doors use what types?
See Section 087100: 3.9 Door Hardware Schedule.
23 Door Hardware: Who provides the locks and any related hardware? All specified items to be provided by Contractor.
24 Door Hardware: REX PIRs are specified for doors with no panic bars–which are those doors? All access control doors require a request to exit device integral to the lock.
25 Door Hardware: Push Buttons are specified (normally associated with mag locks)–which doors require mag locks?
Required for all panic devices or remote door opening.
26 Door Hardware: Spec calls for DTMOMA-2 push button console for remote door opening.
How many consoles required? Which doors require this remote release? Where will the console(s) be located?
See Section 087100: 3.9 Door Hardware Schedule.
27 CCTV System: Analog or IP System? Specs seem to indicate an Analog system. IP based system on a physically separate network from the Forest Service network.
28 CCTV System: Color and B/W cameras are specified–which goes where? provide all B/W cameras.
29 CCTV System: PTZ cameras and PTZ controls are mentioned in spec–how many of each and where?
All CCTV cameras are to be fixed.
30 Is the USDA Forest Service will be having a pre bid meeting for this solicitation and if not with who we can coordinate a Site Visit?
See Item #1.
31 Please let us know if there is going to be a Site Visit. If so please inform date and time. See Item #1.
32 In the specifications, Section 102113.17, the partitions that are required is of the Solid
Phenolic Core material, however, on Sheet A-600 Interior Finishes, 102113-17 of the drawings the material is required to be Solid Plastic HDPE from Bradmar Partitions. Which of the two materials should we quote?
Provide solid phenolic toilet partitions. Delete references to other materials.
33 Can the government please confirm if the PC-607 Renovation of Catalina Headquarter project is considered Design-Build, or Design-Bid-Build? Several sections of the RFP give an indication that A&E services are required for this project.
Project is Design-Bid-Build. Construction documents are complete. Any design required is incidental to construction.
34 We don’t find the solicitation document in the attachments. Also, need to know is there had being a pre-bid meeting for this project. Will this be a bid process or negotiation?
See Items #1, #2 and #33.
35 Is a bid bond required? Provide Bid Bond.
36 In (Section L) the Submission Instructions asked the GC's to submit the proposal through email. If the proposal file is too big to send through email, please advise on what should be done if this occurs.
If unable to upload documents, Offerors may send in multiple emails or send in zip files to shundrica.daniels@usda.gov.
37 I was trying to log in the Eventbrite page to reserve for site visit. Is it available any spot? See Item #1.
38 After reviewing all documents included in the Solicitation, I need to know, does this solicitation ask for a Designer? Will be design-build as per Facilities Design Requirements-
April 2020?
See Item #33.
39 There are 140 drawings in Revitalization of Catalina Headquarters & Site. Are these existing drawings? They are dated 06/22/2020.
The drawings dated 06/22/2020 are the Construction Documents for this Project.
40 Hurricane Damage Assessment for The Catalina Field Office and El Yunque National Forest-
Unit 0816 document is provided, but wanted to make sure that only information pertaining
Catalina will be take in account and disregard all info about El Yunque National Forest-Unit, right?
In formation in the Hurricane Damage Assessment for The Catalina Field Office is only relevant to the extent it applies to the SOW Catalina. Any other information is For Information Only.
41 LEED Checklist is provided. Is this project already filed in the USGBC? Only LEED Silver is required?
This project has been designed to LEED Silver standards only. It will not be registered with USGBC.
42 Is the security analysis by the Contractor? Yes.
43 Is the commissioning and getting the certification of green building by the Contractor? Commissioning is by the Contractor. The building will not be registered with the USGBC. See Item #41.
44 In Drawing HQ.AD101 AND HQ.AD102 indicates that the entire “stucco system” has to be removed and applied new but on the visit, we were able to see that the entire building is painted/cement plastered. Please indicate how do we proceed.
Existing exterior finishes to be removed as indicated. Substrate to be prepared per manufacturer's recommendations for new plaster and paint finish.
45 In Drawing C-101 indicates we have to remove several tress, the permits will be by the
Contractor or by the Owner?
No tree removal permits are required. Price removal of trees indicated. However, the removal of any tree will need to be approved by and coordinated with the Government during construction.
46 Is it possible to submit a substitution for the Precast Structure due to the project being located in Puerto Rico? Ground freight is not available from the US and a structure of this size and weight will be difficult to transport.
Substitutions are not being considered during the solicitation phase. Provide an allowance for what is indicated.
47 Can you provide electrical bills so the PV system can be accurately estimated? OPTION ITEM NO. 1 - Solar Installation has been deleted from this Solicitation.
48 If more area is needed for the solar panels than available/proposed, should we assume we have to build additional structures or should we limit the amount of panels to the available area shown in the drawings?
OPTION ITEM NO. 1 - Solar Installation has been deleted from this Solicitation.
49 Please provide additional details of the chain link fence: tube diameters, tube gage, height, top rail and bottom rail information, etc.
See Detail C, Sheet C-503.
50 Note 7 on HQ.A-201 says that shutters shall be installed in all new windows and storefront system. In the drawing elevations it also puts the note on exterior doors. Does this apply to all exterior openings, including doors and louvres, or just windows?
Windows and glass storefront doors.
51 The first level bathrooms indicate in the finishes table that they have CT but it doesn’t specify which.
See item #6.
52 The walls of all the bathrooms say CT but it doesn’t say which. See Item #6.
53 For the kitchen backsplash it says CT-2 but CT-2 is 12”x24” which is a strange choice for backsplash. Please clarify and/or confirm.
See Item #7.
54 In Page C-502 in the Drawings there's a 12" subgrade compacted to 95% MOD. Proctor
Test. Just to confirm, this will be the existing ground material or will a specific material be used?
Existing material.
55 Will the Hurricane rolling shutters be electric or manual? Color will be specified by the architect. Will there be a specific color/ finishing process for the shutters?
Electric operation with manual override. The shutters on the building entrances must provide a means to manually operate the shutter from the outside, in case of a full power outage. Color will be selected by the USFS from manufacturer's standard color palette.
56 Please provide specific veneer details for millwork.
57 For the construction of the 2" force main shown on Drawing C-105, the Contractor shall perform some vegetation clearing along the pipeline path:
Provide seedless, biodegradable geotextile material to prevent mud runoff at impacted areas.
58 Who is responsible for permits? This project is on federal property, so no building construction permit is required for the Government of PR.
However, applicable codes apply.
59 Is there vegetation to be protected? Please indicate. All vegetation shall be protected.
60 Is a tree mitigation plan necessary? Please provide. All trees indicated to be removed to be inspected by USFS prior to removal.
61 Please provide information for vegetation restoration for this area, if any. See Item #57. Provide an allowance for areas round the main building impacted by heavy equipment, personnel activities, the removal of trees, etc.
Question Tracking Form
Revitalization of Catalina Headquarters Building and Site
8/28/2020 Catalina Question Tracking Form_28Aug20 Final 1 of 1
SUBMITTAL
TRANSMITTAL
Project: Mold Remediation, Demo and Roof Date: 9/28/2018 Replacement - Cataline HQs, PR GBA Project Number: 2018001YNQ
Submittal No. 010 Resubmission
To (USDA Forest Service): Date: 9/28/2018 From (G. Batista & Associates): By: Greg Batista
Qty.
Submitted for review and approval Substitution involved - Substitution request attached Resubmitted for review and approval If substitution involved, submission includes Complies with contract requirements point-by-point comparative data or preliminary details Will be available to meet construction schedule Items included in submission will be ordered A/E review time included in construction schedule immediately upon receipt of approval
Other remarks on above submission: One copy retained by sender
To (G. Batista & Associates): Date:
From (USDA Forest Service): By:
Date Rec'd: Date Trnsmt'd:
Approved Revise / Resubmit Approved as noted Rejected / Resubmit
Other remarks on above submission: One copy retained by sender
To (A&E): Attn:
From (Contractor): By:
Date Rec'd : Date Trnsmt'd:
Approved Not subject to review Approved as noted Provide file copy with corrections identified No action required Sepia copies only returned Revise / Resubmit Point-by-point comparative data required to complete Rejected / Resubmit approval process Approved as noted / Resubmit Submission Incomplete / Resubmit
Other remarks on above submission: One copy retained by sender
To (Contractor): Attn:
From (A&E): By:
Date Rec'd: Date Trnsmt'd:
Copies: Owner Consultants One copy retained by sender
TRANSMITTAL
A
Spec. Section Title and Paragraph / Drawing Detail Reference Reference / Number Title / Description / Manufacturer
010 Roofing Cut Sheets
TRANSMITTAL
TRANSMITTAL
TRANSMITTAL
Other
C. Shope
APPROVED AS NOTED
Panel Thickness:
3.25” 4” 5” 6”
Insulating Values (R):** 26 32 41 49
SR2 Product Data Sheet
Standing Seam Roof Panel
INNOVATIVE.
ADAPTABLE.
ENERGY EFFICIENT.
TESTED & APPROVED
All Weather Insulated Panels’ products have been extensively tested under a variety of North American standards:
FM 4880: Class 1 Fire Rating FM 4471: Class 1 Roof Assembly CAN/ULC S102: Flame Spread CAN/ULC S126: Flame Spread (Roof) ASTM C518/C1363: Thermal Transmission ASTM E1646: Water Penetration ASTM E1680: Air Infiltration ASTM E72: Structural Strength
FLORIDA APPROVED
The look of traditional standing seam integrated with the benefits of an insulated metal panel - a great alternative to field assembled roofing components.
FEATURES AND BENEFITS
• Field seamed, hidden fastener joinery provides maximum protection against the elements.
• The trapezoidal rib design provides added strength against potential foot traffic damage compared to other standing seam roof products.
• The standard exterior metal surface is smooth 26ga G-90 galvanized steel with standard PVDF and SMP exterior coatings (other coatings may be available).
• The standard interior metal surface is embossed 26ga Imperial White.
• The panel arrives on site in one piece and requires a simple one-step installation reducing construction time and costs.
PRODUCT PARAMETERS
Panel Width: 40”
Panel Length: 8’ min to 50’ maximum based on a 48’ flatbed trailer length. Consult your sales representative for other available lengths.
Insulation Material: CFC-free foamed-in-place polyisocyanurate foam 2.1 to 2.5 pcf density.
Joint Configuration: 90o field seamed.
Metal facings: 26ga galvanized steel (22ga, 24ga available).
Coatings: PVDF & SMP (other coatings available).
Accessories: fasteners, standing seam clip assemblies, sealants, brake formed flashings.
**R-Value tested in accordance with ASTM C518/C1363 at 40oF mean temperature, adjusted for a windspeed of 15 mph.
©2015 All Weather Insulated Panels (AWIP) – All rights reserved. In accordance with ongoing efforts to improve our products and their performance, AWIP reserves the right to change without notice the specifications herein. These contents are for general information only and are not intended to serve as any type of advice. Every effort is made to ensure the accuracy of the information included herein and it is believed to be accurate and reliable as of the date of publication. AWIP does not warrant or represent the accuracy or reliability of any information included in this brochure. Any reliance on any information without consultation with AWIP or a duly authorized representative shall be at the user’s own risk.
U.S.A 929 Aldridge Rd. Vacaville, CA 95688 15000 Panatella Pkwy Little Rock, AR 72206
1-888-970-AWIP (2947)
awipanels.com
All Weather SR2 Roof Panel Specifications
Pre-Insulated Metal Panels
Division 7, Section 07400
Part 1 – General
1.01 Description
Furnish and install all steel faced factory insulated roof panels forming the exterior cladding and the related accessories and trims required for a complete weathertight roof installation.
1.02 Design
The metal faced foam core roof panels shall be produced on a continuous process manufacturing line under strict quality control and must be independently audited quarterly by a recognized audit facility/testing lab. Panel thickness, gauges, spans between supports and overall lengths shall be as required to contribute to the combined action of the roof in resisting the specified design loads with a deflection not to exceed L/240.
1.03 Shop Drawings
Contractor shall furnish detailed drawings showing location and profile of insulated panels, as well as location and shape of formed metal flashings, and the location and type of sealants and fasteners.
1.04 Acceptable Manufacturers
Insulated wall panels shall be manufactured by All Weather Insulated Panels, 929 Aldridge Rd, Vacaville, CA 95688, 888-970-AWIP, www.awipanels.com
1.05 Substitutions
This specification is written with the SR2 roof panel as the basis of acceptable design, quality and performance. Requests for substitutions must be submitted in writing no less than 14 days prior to bid.
Part 2 – Products
2.01 Material
A. The insulated metal roof panel shall be _____ (3.25, 4, 5 and 6) inches thick and 40 inch wide as detailed on the design drawings. The side joint shall be a 2” high trapezoidal standing seam rib design utilizing a continuous non-skinning butyloid sealant bead. ¼-
14 hex head fasteners shall be installed through the pre-punched hidden SR series joint clip. The clip assembly shall positively lock the face and liner sheet of the panel to the structural supports and provide positive resistance to negative wind loads. An additional minimum 1/4 inch continuous bead of approved non-skinning butyloid gun grade sealant equivalent to Schnee-Morehead 5430 may be applied at the liner side grooved joint of the roof panel joint prior to engagement as shown on the panel shop/erection drawings .
B. The panel exterior shall be SR2. The exterior metal substrate shall be 26ga G90 Galvanized or AZ50 Galvalume Steel coated with a 30 year PVDF finish with a total dry film thickness of 1.0 mil including primer. The exterior color shall be selected from manufacturer’s six in-stock standards. The panel interior shall have lightly planked mesa ribs on 2.22” centers. The interior metal substrate shall be minimum 26ga G60
Galvanized or AZ35 Galvalume Steel coated with a polyester finish with a dry film thickness of 1.0 mil including primer. Interior color shall be Imperial White.
C. The continuously foamed in-place panel core shall be Class 1 rigid polyisocyanurate (polyurethane) foam meeting the physical properties listed under section 2.02 G.
D. The insulated panel manufacturer shall furnish either the formed metal flashings or the flat stock in the same gauge, color and paint finish system as the panel facings.
2.02 Performance Tests
A. The panels ability to withstand positive and negative design loads shall be verified by testing in accordance with the ASTM E 72 Vacuum Chamber Method with the standard deflection criteria to be L/240.
B. The panel thermal properties shall be verified by actual tested values in accordance with the ASTM C 518 steady state thermal transmission test method. Aged K Factor shall not exceed .14 @ 75º F mean temperature or .13 @ 40º F mean temperature.
C. The panel core shall have a flame spread maximum of 25 and smoke developed maximum of 450 as tested in accordance with the ASTM E 84 test method.
D. The panel shall have Factory Mutual Class 1 Approval for wall and roof/ceiling construction in accordance with the full scale FM 4880 test program with no height restriction.
E. The panels shall have Factory Mutual Approval for wind uplift, hailstorm, foot traffic, and spread of flame (ASTM E 108- Class A rated) in accordance with FM 4471.
F. The polyisocyanurate foam core shall meet or exceed the following physical properties:
i. Compressive Strength: 25 psi
ii. Density (in-place): 2.1-2.5 pcf
iii. Shear Strength: 28-32 psi
iv. Closed Cell Content: 95%
v. Dimensional Stability: 14 day aged (ASTM D 2126) -20 degree F <
1% chg, dry heat 158 degree F < 1% chg, Humid Heat 158 degree F H. Panels not meeting these testing and performance criteria are not permitted to be used for this exterior roof application.
Part 3 – Execution
3.01 For quality panel installation, the contractor/installer shall examine the alignment of the structural steel before installing the metal wall panels. The steel shall be aligned to the tolerances established in the AISC code of standard practice, section 7, and the supplemental modification control section 7.11.3, adjustable items. The maximum deviation of steel alignment shall be limited to -0 = 3/16” from the control with a 1/8” maximum change in deviation for any member of any 10’-0” run of panel. The erector shall not proceed with installation if the structural steel is not within the specified tolerances. The face of all structural members to which the panels are attached must be in the same vertical plane, flat and free of obstructions such as weld marks, bolts or rivet heads. Roof panels shall only be mechanically attached to structural or secondary roof framing that is running perpendicular the roof panel lengths.
3.02 The metal roof panels shall be erected by an experienced metal panel contractor in accordance with the approved drawings, specifications and installation instructions.
3.03 The applicable seaming tools, motorized or crimp style, shall be as specifically recommended by your AWIP sales or technical representative. These seaming tools can be purchased or rented through an AWIP approved seaming tool manufacturer/distributor.
3.04 Manufacturer shall provide panel contractor with written instructions for recommended product storage and handling.
3.05 Repair or replace any damaged or defective panels after determination of responsibility.
3.06 Manufacturer shall warrant the panels as free from defects in material and workmanship for 2 years from the date of production.
3.07 Manufacturer shall warrant that the exterior paint finish will not:
A. Chip, crack, check, or peel for a period of (30) thirty years from date of installation (except for such crazing that may occur on tightly roll-formed edges and brake bends).
B. Chalk in excess of a numerical rating of (8) for a period of (30) thirty years from date of installation when measured in accordance with the standard procedures outlined in ASTM D-659.
C. Fade or change color in excess of (5) E units for a period of (30) thirty years from date of installation when calculated in accordance with ASTM D-2244. The color change is to be measured on exposed painted surface cleaned of surface soils and oxidation.
Project: Mold Remediation, Demo and Roof Date: 9/28/2018 Replacement - Cataline HQs, PR GBA Project Number: 2018001YNQ
Submittal No. 010A Resubmission
To (USDA Forest Service): Date: 9/28/2018 From (G. Batista & Associates): By: Greg Batista
Qty.
Submitted for review and approval Substitution involved - Substitution request attached Resubmitted for review and approval If substitution involved, submission includes Complies with contract requirements point-by-point comparative data or preliminary details Will be available to meet construction schedule Items included in submission will be ordered A/E review time included in construction schedule immediately upon receipt of approval
Other remarks on above submission: One copy retained by sender
To (G. Batista & Associates): Date:
From (USDA Forest Service): By:
Date Rec'd: Date Trnsmt'd:
Approved Revise / Resubmit Approved as noted Rejected / Resubmit
Other remarks on above submission: One copy retained by sender
To (A&E): Attn:
From (Contractor): By:
Date Rec'd : Date Trnsmt'd:
Approved Not subject to review Approved as noted Provide file copy with corrections identified No action required Sepia copies only returned Revise / Resubmit Point-by-point comparative data required to complete Rejected / Resubmit approval process Approved as noted / Resubmit Submission Incomplete / Resubmit
Other remarks on above submission: One copy retained by sender
To (Contractor): Attn:
From (A&E): By:
Date Rec'd: Date Trnsmt'd:
Copies: Owner Consultants One copy retained by sender
TRANSMITTAL
TRANSMITTAL
TRANSMITTAL
010A Roofing Shop Drawings
TRANSMITTAL
A
Spec. Section Title and Paragraph / Drawing Detail Reference Reference / Number Title / Description / Manufacturer
Other
Structural Steel & Miscellaneous Fabrication Department
PO BOX 5309
CAGUAS, PR 00726 TRANSMITTAL SHEET
(787)747-9415 fax: (787) 523-0001
To: G BATISTA & ASSOCIATES Date: SEP-21-2018
EL YUNQUE NATIONAL FOREST Attention of: GREG BATISTA
Project: NEW STANDING ROOF SYSTEM FOR CATALINA BUILDING
WE ARE DELIVERING:
These Prints are for:
By Messenger
X Approval As requested
Regular Mail
Resubmittal
Email X
As Noted Field Use
Item No. of Prints Dwg. No. Title of Drawing
PDF 1 ISO-1 ISOMETRIC VIEW
PDF 1 E-1 ERECTION DRAWINGS - PLAN VIEW, SECTIONS & DETAILS
PDF 1 E-2 ROOF STANDING SEAM DETAILS
PDF 1 SK-1 COLOR CHART
PDF 1 SK-2 PRODUCT DATA
Received By:
Date: Structural Steel & Miscellaneous Fabrication Department
NOTE: MATERIAL DELIVERIES HAVE TO BE COORDINATED WITH
DETAILER. WITH ENOUGH AMPLE TIME TO FABRICATE.
PLEASE ALLOW 10 WORKING DAYS FOR FABRICATION.
APPROVED DRAWINGS OR WRITTEN AUTHORIZATION ARE By: C. RAMOS / G. VIDAL
REQUIRED TO RELEASE MATERIAL FOR FABRICATION.
Steel and Pipes, Inc.
gregbatista Typewritten Text
G.BATISTA & ASSOCIATES
SHOP DRAWING REVIEW BY GB
DATE : 9/21/18 6:05PM
STATUS: REVIEWED AND APPVD
C. Shope Text Box Provide actual color samples.
C. Shope Text Box Provide warranty.
INDICATED PART SIDE MARK.
PLEASE ACKNOWLEDGE THAT STEEL AND PIPES
IS A MANUFACTURING COMPANY, NOT ARCHITECTS
OR STRUCTURAL DESIGNERS. STEEL AND PIPES IS
NOT RESPONSIBLE OR LIABLE FOR ANY DEFECTS OR
ACCIDENTS CAUSED AS A RESULT OF THESE DRAWINGS.
WE STRONGLY SUGGEST YOU CONSULT AN ARCHITECT
OR ENGINEER FOR FINAL DESIGN AND/OR APPROVAL.
FABRICATION NOTE:
STEEL AND PIPES DETAILS ARE PREPARED AS PER DESIGN
PROVIDED BY CLIENT. OTHERWISE, OUR DETAILS ARE
SUGGESTED AND ARE SUBJECT TO CLIENT'S QUALIFIED
ENGINEER OR ARCHITECT EVALUATION AND APPROVAL.
WE ARE NOT RESPONSIBLE FOR DESIGN OR CALCULATIONS.
DRAWINGS FOR
APPROVAL NOT
FOR FIELD USE
ALL DIMENSIONS, ANGLES, ELEVATIONS
OR OTHER DATA GIVEN IN THESE
DRAWINGS TO BE KEPT. STRUCTURAL
STEEL TO BE FABRICATED AS PER THIS
DATA. STEEL & PIPES MUST BE ADVISED
OF ANY DEVIATION TO THIS DATA, UPON
DRAWINGS ACCEPTANCE BY GENERAL
CONTRACTOR TO USED
FOR FILES AND FIELD USE
NOTES:
X6.
DRAWINGS SUBMITTED FOR
APPROVAL ON SEP-21-2018
RETURN ONE COPY OF
DRAWING SUBMITTED
STEEL & PIPES TO BEGIN
FABRICATION UPON RECEIVE
OF FINAL APPROVED DRAWING
1. ALL MATERIAL GALVANIZED STEEL A-36, EXCEPT TUBING.
2. FOR TUBING GALVANIZED STEEL A-500 GR. B.
3. GALVANIZED STEEL BEFORE FABRICATION.
4. COLD GALVANIZED WILL BE APPLIED TO ALL.
GALVANIZED CUTS AND WELDS.
5. FOR STANDING SEAM DECKSPECIFICATION,
SEE NOTE BESIDE DECK.
GREG BATISTA
C.R.L.
ISOMETRIC VIEW
CATALINA HEADQUARTERS
18-643
G BATISTA-ASSOCIATES
EL YUNQUE NATIONAL FOREST
CATALINA HEADQUARTERS
ISO-109/18/2018
EL YUNQUE NATIONAL FOREST
ONE S/C OF RED OXIDE
A36
0 ISSUED FOR APPROVAL C.R.L 09/21/2018
U/N
I
PS
& STEEL AND PIPES, INC.
SHEET NO.JOB NO.
REVISION DESCRIPTIONMARK
CHECKED BY:
SHEET TITLE:
DATEBY:
DRAWN BY:DATE: DATE:
P.O. BOX 5309 CAGUAS, P.R. 00726
CONTACT:CLIENT: PROJECT:
U/N
U/N
U/N
U/N
SHOP NOTES
SHOP BOLTS:
FIELD BOLTS:
PAINT :
WELDING :
OPEN HOLES:
ALL MAT'L. :
QUALITY CONTROL:
TEL. 747-9415 FAX. 523-0001 e-mail: gvidal@steelandpipes.com
3d
GREG BATISTA
C.R.L.
ERECTION PLAN
CATALINA HEADQUARTERS
18-643
G BATISTA-ASSOCIATES
EL YUNQUE NATIONAL FOREST
CATALINA HEADQUARTERS
E-109/18/2018
EL YUNQUE NATIONAL FOREST
ONE S/C OF RED OXIDE
A36
0 ISSUED FOR APPROVAL C.R.L 09/21/2018
U/N
I
PS
& STEEL AND PIPES, INC.
SHEET NO.JOB NO.
REVISION DESCRIPTIONMARK
CHECKED BY:
SHEET TITLE:
DATEBY:
DRAWN BY:DATE: DATE:
P.O. BOX 5309 CAGUAS, P.R. 00726
CONTACT:CLIENT: PROJECT:
U/N
U/N
U/N
U/N
SHOP NOTES
SHOP BOLTS:
FIELD BOLTS:
PAINT :
WELDING :
OPEN HOLES:
ALL MAT'L. :
QUALITY CONTROL:
TEL. 747-9415 FAX. 523-0001 e-mail: gvidal@steelandpipes.com
A
C
D
E
ROOF DECK LAYOUT
654321
A - A
DETAIL B B - B
PLEASE ACKNOWLEDGE THAT STEEL AND PIPES
IS A MANUFACTURING COMPANY, NOT ARCHITECTS
OR STRUCTURAL DESIGNERS. STEEL AND PIPES IS
NOT RESPONSIBLE OR LIABLE FOR ANY DEFECTS OR
ACCIDENTS CAUSED AS A RESULT OF THESE DRAWINGS.
WE STRONGLY SUGGEST YOU CONSULT AN ARCHITECT
OR ENGINEER FOR FINAL DESIGN AND/OR APPROVAL.
FABRICATION NOTE:
STEEL AND PIPES DETAILS ARE PREPARED AS PER DESIGN
PROVIDED BY CLIENT. OTHERWISE, OUR DETAILS ARE
SUGGESTED AND ARE SUBJECT TO CLIENT'S QUALIFIED
ENGINEER OR ARCHITECT EVALUATION AND APPROVAL.
WE ARE NOT RESPONSIBLE FOR DESIGN OR CALCULATIONS.
DRAWINGS FOR
APPROVAL NOT
FOR FIELD USE
ALL DIMENSIONS, ANGLES, ELEVATIONS
OR OTHER DATA GIVEN IN THESE
DRAWINGS TO BE KEPT. STRUCTURAL
STEEL TO BE FABRICATED AS PER THIS
DATA. STEEL & PIPES MUST BE ADVISED
OF ANY DEVIATION TO THIS DATA, UPON
DRAWINGS ACCEPTANCE BY GENERAL
CONTRACTOR TO USED
FOR FILES AND FIELD USE
NOTES:
X6.
DRAWINGS SUBMITTED FOR
APPROVAL ON SEP-21-2018
RETURN ONE COPY OF
DRAWING SUBMITTED
STEEL & PIPES TO BEGIN
FABRICATION UPON RECEIVE
OF FINAL APPROVED DRAWING
DECK TO EXISTING CONCRETE ROOF
ATTACHMENT DETAIL
1. ALL MATERIAL GALVANIZED STEEL A-36, EXCEPT TUBING.
2. FOR TUBING GALVANIZED STEEL A-500 GR. B.
3. GALVANIZED STEEL BEFORE FABRICATION.
4. COLD GALVANIZED WILL BE APPLIED TO ALL.
GALVANIZED CUTS AND WELDS.
5. FOR STANDING SEAM DECKSPECIFICATION,
SEE NOTE BESIDE DECK.
INDICATED PART SIDE MARK.
SR-2 STANDING SEAM 40" ROOF PANEL
22 Ga. NON EMBOSSED IN STOCK STANDARD
COLOR AW1000 EXTERIOR 3.25" URE CORE
26 Ga. EMBOSSED IMPERIAL WHITE AW100
MESA PROFILE INTERIOR
A
A
4/
109'-0"
28'-4" 16'-0" 16'-0" 16'-0" 32'-8"
E-2
E-2
SR-2 STANDING SEAM 40" ROOF PANEL
22 Ga. NON EMBOSSED IN STOCK STANDARD
COLOR AW1000 EXTERIOR 3.25" URE CORE
26 Ga. EMBOSSED IMPERIAL WHITE AW100
MESA PROFILE INTERIOR
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
E-2
E-2
HSS2X1X18/ HSS2X1X18/
HSS2X1X18/
E-2
E-2
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
E-2
E-2
HSS2X1X18/
HSS2X1X18/ HSS2X1X18/
HSS2X1X18/
E-2
E-2
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
E-2
E-2
HSS2X1X18/ HSS2X1X18/ HSS2X1X18/
4/
E-2
E-2
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
E-2
E-2
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/
HSS2X1X18/ HSS2X1X18/
5'-0"
4'-0"
40'-0
30'-0
5'-0"
5'-0"
5'-0"
5'-0"
5'-0"
3" 5'-0"
5'-0"
5'-0"
5'-0"
5'-0" 3"
30'-0"
DET. B
4'-0"
9" 9"
5'-0"
B
B
6"
1" 4" 1"
M A X S P A C
IN
G TYP.
14/ " Ø X 3 12/ " - ZINC PLATED
WEDGE ANCHORS
BY SIMPSON (2"EMBEDED)
14/ " Ø X 3 12/ " - ZINC PLATED
WEDGE ANCHORS
BY SIMPSON (2"EMBEDED)
HSS2X1X1
8/
PL1
4/ "X2" X 0'-6"
PL1
4/ "X2" X 0'-6"
SR-2 STANDING SEAM 40" ROOF PANEL
22 Ga. NON EMBOSSED IN STOCK STANDARD
COLOR AW1000 EXTERIOR 3.25" URE CORE
26 Ga. EMBOSSED IMPERIAL WHITE AW100
MESA PROFILE INTERIOR
FABRICATION NOTE:
STEEL AND PIPES DETAILS ARE PREPARED AS PER DESIGN
PROVIDED BY CLIENT. OTHERWISE, OUR DETAILS ARE
SUGGESTED AND ARE SUBJECT TO CLIENT'S QUALIFIED
ENGINEER OR ARCHITECT EVALUATION AND APPROVAL.
WE ARE NOT RESPONSIBLE FOR DESIGN OR CALCULATIONS.
DRAWINGS FOR
APPROVAL NOT
FOR FIELD USE
ALL DIMENSIONS, ANGLES, ELEVATIONS
OR OTHER DATA GIVEN IN THESE
DRAWINGS TO BE KEPT. STRUCTURAL
STEEL TO BE FABRICATED AS PER THIS
DATA. STEEL & PIPES MUST BE ADVISED
OF ANY DEVIATION TO THIS DATA, UPON
DRAWINGS ACCEPTANCE BY GENERAL
CONTRACTOR TO USED
FOR FILES AND FIELD USE
NOTES:
X6.
DRAWINGS SUBMITTED FOR
APPROVAL ON SET-21-2018
RETURN ONE COPY OF
DRAWING SUBMITTED
STEEL & PIPES TO BEGIN
FABRICATION UPON RECEIVE
OF FINAL APPROVED DRAWING
SR-2 STANDING SEAM 40" ROOF PANEL
22 Ga. NON EMBOSSED IN STOCK STANDARD
COLOR AW1000 EXTERIOR 3.25" URE CORE
26 Ga. EMBOSSED IMPERIAL WHITE AW100
MESA PROFILE INTERIOR
SR-2 STANDING SEAM 40" ROOF PANEL
22 Ga. NON EMBOSSED IN STOCK STANDARD
COLOR AW1000 EXTERIOR 3.25" URE CORE
26 Ga. EMBOSSED IMPERIAL WHITE AW100
MESA PROFILE INTERIOR
SR-2 STANDING SEAM 40" ROOF PANEL
22 Ga. NON EMBOSSED IN STOCK STANDARD
COLOR AW1000 EXTERIOR 3.25" URE CORE
26 Ga. EMBOSSED IMPERIAL WHITE AW100
MESA PROFILE INTERIOR
1. ALL MATERIAL GALVANIZED STEEL A-36, EXCEPT TUBING.
2. FOR TUBING GALVANIZED STEEL A-500 GR. B.
3. GALVANIZED STEEL BEFORE FABRICATION.
4. COLD GALVANIZED WILL BE APPLIED TO ALL.
GALVANIZED CUTS AND WELDS.
5. FOR STANDING SEAM DECKSPECIFICATION,
SEE NOTE BESIDE DECK.
INDICATED PART SIDE MARK.
PLEASE ACKNOWLEDGE THAT STEEL AND PIPES
IS A MANUFACTURING COMPANY, NOT ARCHITECTS
OR STRUCTURAL DESIGNERS. STEEL AND PIPES IS
NOT RESPONSIBLE OR LIABLE FOR ANY DEFECTS OR
ACCIDENTS CAUSED AS A RESULT OF THESE DRAWINGS.
WE STRONGLY SUGGEST YOU CONSULT AN ARCHITECT
OR ENGINEER FOR FINAL DESIGN AND/OR APPROVAL.
GREG BATISTA
C.R.L.
ROOF STANDING SEAM DETAILS
CATALINA HEADQUARTERS
18-643
G BATISTA-ASSOCIATES
EL YUNQUE NATIONAL FOREST
CATALINA HEADQUARTERS
E-209/21/2018
EL YUNQUE NATIONAL FOREST
ONE S/C OF RED OXIDE
A36
0 ISSUED FOR APPROVAL C.R.L 09/21/2018
U/N
I
PS
& STEEL AND PIPES, INC.
SHEET NO.JOB NO.
REVISION DESCRIPTIONMARK
CHECKED BY:
SHEET TITLE:
DATEBY:
DRAWN BY:DATE: DATE:
P.O. BOX 5309 CAGUAS, P.R. 00726
CONTACT:CLIENT: PROJECT:
U/N
U/N
U/N
U/N
SHOP NOTES
SHOP BOLTS:
FIELD BOLTS:
PAINT :
WELDING :
OPEN HOLES:
ALL MAT'L. :
QUALITY CONTROL:
TEL. 747-9415 FAX. 523-0001 e-mail: gvidal@steelandpipes.com
C. Shope Text Box
ALL ANCHOR PLATES TO BE SET IN A BED OF SEALANT.
SUBMIT CUT SHEET FOR PROPOSED SEALANT.
©2015, All Weather Insulated Panels. All rights reserved. Printed in U.S.A.
Color Availability Chart
PVDF
In-Stock Colors
SMP
In-Stock Colors
PVDF
Non-Stock Colors
Interior Colors
Sandstone Surrey Beige Regal White
Royal Blue Natural Green Pearl Gray
Imperial White Sandstone Surrey Beige
Warm White Slate Gray Evergreen
Slate Blue Colonial Red Weathered Copper
Imperial White
The colors shown here are representative only and not necessarily true reproductions of actual coating colors.
Coil coat color chips are available upon request. For further information regarding color availability, please contact your local sales representative.
▪ Embossed metal surfaces are offered as a standard on wall panels and non-embossed (smooth) for roof panels. Non-embossed finishes may be available on wall panels upon request depending on color, gauge and end use.
▪ The standard interior paint finish for all panels is imperial White. All other colors are available as exterior facings.
▪ AdobeTexture™ finish is available in
Sandstone, Surrey Beige, Pearl Gray and Regal White only.
▪ Non-stock colors and paint systems and special orders are typically subject to higher pricing and may
| increase | lead | times | from | point | of | order. | |
| ▪ Complete | paint | system | specifications | ||||
| and | standard | finish | warranties | are |
available upon request.
Corporate Headquarters 929 Aldridge Road
Vacaville, CA 95688
TOLL FREE: (888) 970-AWIP (2947)
EMAIL: sales@awipanels.com WEB: awipanels.com
SK-1
gregbatista Typewritten Text
POLYVINYL (LIKE KYNAR)
gregbatista Typewritten Text gregbatista Typewritten Text
SILICONE MODIFIED POLYESTER PAINT
gregbatista Typewritten Text gregbatista Typewritten Text
C. Shope Text Box Preferred color. Will verify with samples.
Panel Thickness:
3.25” 4” 5” 6”
Insulating Values (R):** 26 32 41 49
SR2 Product Data Sheet
Standing Seam Roof Panel
INNOVATIVE.
ADAPTABLE.
ENERGY EFFICIENT.
TESTED & APPROVED
All Weather Insulated Panels’ products have been extensively tested under a variety of North American standards:
FM 4880: Class 1 Fire Rating FM 4471: Class 1 Roof Assembly CAN/ULC S102: Flame Spread CAN/ULC S126: Flame Spread (Roof) ASTM C518/C1363: Thermal Transmission ASTM E1646: Water Penetration ASTM E1680: Air Infiltration ASTM E72: Structural Strength
FLORIDA APPROVED
The look of traditional standing seam integrated with the benefits of an insulated metal panel - a great alternative to field assembled roofing components.
FEATURES AND BENEFITS
• Field seamed, hidden fastener joinery provides maximum protection against the elements.
• The trapezoidal rib design provides added strength against potential foot traffic damage compared to other standing seam roof products.
• The standard exterior metal surface is smooth 26ga G-90 galvanized steel with standard PVDF and SMP exterior coatings (other coatings may be available).
• The standard interior metal surface is embossed 26ga Imperial White.
• The panel arrives on site in one piece and requires a simple one-step installation reducing construction time and costs.
PRODUCT PARAMETERS
Panel Width: 40”
Panel Length: 8’ min to 50’ maximum based on a 48’ flatbed trailer length. Consult your sales representative for other available lengths.
Insulation Material: CFC-free foamed-in-place polyisocyanurate foam 2.1 to 2.5 pcf density.
Joint Configuration: 90o field seamed.
Metal facings: 26ga galvanized steel (22ga, 24ga available).
Coatings: PVDF & SMP (other coatings available).
Accessories: fasteners, standing seam clip assemblies, sealants, brake formed flashings.
**R-Value tested in accordance with ASTM C518/C1363 at 40oF mean temperature, adjusted for a windspeed of 15 mph.
©2015 All Weather Insulated Panels (AWIP) – All rights reserved. In accordance with ongoing efforts to improve our products and their performance, AWIP reserves the right to change without notice the specifications herein. These contents are for general information only and are not intended to serve as any type of advice. Every effort is made to ensure the accuracy of the information included herein and it is believed to be accurate and reliable as of the date of publication. AWIP does not warrant or represent the accuracy or reliability of any information included in this brochure. Any reliance on any information without consultation with AWIP or a duly authorized representative shall be at the user’s own risk.
U.S.A 929 Aldridge Rd. Vacaville, CA 95688 15000 Panatella Pkwy Little Rock, AR 72206
1-888-970-AWIP (2947)
awipanels.com
SK2
LIMITED PANEL WARRANTY
This warranty is solely for the benefit of Customer c/o Owner/Job, and shall not be transferable
Owner: X Project: X AWIP Job #: X Ship Date (month/year): X
1.0 EXPRESS LIMITED WARRANTY
All Weather Insulated Panels (AWIP) warrants to the Building Owner (“Owner”), that subject to the terms, conditions and limitations stated herein;
1.1 Product- The panels fabricated by AWIP are, on delivery to the Customer, free from defects in material and workmanship and, under normal use and service and if properly installed, will not show evidence of excessive deflection or delamination resulting from defective materials or workmanship, for a period of two (2) years from date of shipment to the Customer. The factory interior finish coating of the panels is warranted as free from defects in material and workmanship for a period of two (2) years from the date of shipment to the Customer. This interior paint warranty excludes failures caused by general surface abuse, scratches, washdown with caustic chemicals and direct exposure to corrosive and aggressive environments. The exterior finish film integrity is covered by a separate paint finish limited warranty available upon request from AWIP. The warranty period for any repaired or replaced panels shall be limited to the unexpired warranty period for the originally supplied panels.
2.0 TERMS, CONDITIONS, LIMITATIONS
2.1 During the term of this limited warranty, AWIP, its agents or employees, shall have free and unlimited access to the panel systems during regular business hours. AWIP shall have no obligation under this limited warranty until all bills for installation, supplies and service have been paid in full by the Owner to AWIP’s customer.
Further, AWIP shall have no obligation under this limited warranty until any and all AWIP invoices for materials supplied are paid in full by its customer. AWIP’s failure at any time to enforce any of the terms and/or conditions stated herein shall not be construed to be a waiver of those provisions.
2.2 AWIP shall have no liability hereunder unless the Owner shall first provide AWIP with a written notice of defects in the panel factory finish within thirty (30) days of the discovery thereof. In all cases, such notice must be delivered to AWIP at the above-dated address. The notice furnished by Owner must reference the purchase order number, date of shipment, and contain a description of the warranty claim, plus a copy of the invoice for the panels.
2.3 If any panels fail to meet the above warranty, AWIP will repair or replace on-site any such panels or otherwise restore such panels and will be responsible for labor and/or materials required for such…