This is an Asbestos Survey Report prepared for the proposed VA Hospital Garland project located at three addresses in Garland, Texas: 2300 Marie Curie Boulevard (main five-story hospital building, 167,236 sq. ft.), 700 Walter Reed Boulevard (four-story medical plaza), and 900 North Shiloh Road (single-story storage building, 19,881 sq. ft.). The survey was conducted June 10-19, 2019 by Terracon Consultants, Inc., a firm of Texas Department of State Health Services (TDSHS) licensed asbestos consultants and inspectors, in accordance with EPA regulation 40 CFR 763 (AHERA) and Texas Asbestos Health Protection Rules (TAHPR).
The survey identified numerous asbestos-containing materials (ACM) across all three buildings, with 298 homogeneous areas and 1,004 samples collected from the main hospital, 322 homogeneous areas and 1,073 samples from the plaza building, and 49 homogeneous areas and 169 samples from the storage building. Confirmed ACM includes friable fireproofing in the main building stairwells (gray, tan) and nonfriable materials such as floor tile and mastic, duct sealant, texture on concrete and CMU blocks, caulking, gaskets, wall coverings, and weatherproofing materials throughout all three structures. The report notes significant survey limitations due to locked rooms, occupied medical clinics, and inaccessible areas above suspended ceilings and beneath floor coverings, indicating that additional ACM may be present in these concealed spaces. The document recommends that identified interior ACM be abated prior to any renovation or demolition activities that would disturb these materials, and specifies that abatement must be performed by a State of Texas licensed contractor with third-party air monitoring conducted during removal activities.
View the file
Other files
Show all 31
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Asbestos Survey
Proposed VA Hospital Garland – Three Buildings
2300 Marie Curie Boulevard
Garland, Texas
June 21, 2019 Terracon Project No. 94197779
Prepared for:
Enapay, LLC Mesquite, Texas
Prepared by:
Terracon Consultants, Inc.
Dallas, Texas DRAFT
Terracon Consultants, Inc. 8901 Carpenter Freeway, Suite 100 Dallas, Texas 75247
P [214] 630 1010 F [214] 630 7070 terracon.com/dal las
June 21, 2019
Mr. Marshall Hamilton Enapay, LLC 207 West Main Street Mesquite, Texas 75149
Telephone: 214-607-0247 E-mail: mjh@enapayllc.com
Re: Asbestos Survey
Proposed VA Hospital Garland – Three Buildings 2300 Marie Curie Boulevard
Dear Mr. Hamilton:
The purpose of this report is to present the results of an asbestos survey performed June 10-19, 2019 at the site of the proposed VA Hospital Garland located at 2300 Marie Curie Boulevard, 700 Walter Reed Boulevard, and 900 North Shiloh Road in Garland, Texas. This survey was conducted in general accordance with Terracon Proposal No. P94197779 dated June 6, 2019. We understand this survey was requested due to the planned acquisition of the property.
Terracon appreciates the opportunity to provide this service to Enapay, LLC. If you have any questions regarding this report, or if you need assistance with project oversight and air monitoring during renovation or demolition of the on-site structures, please contact the undersigned at (214) 630-1010.
Sincerely, Terracon Consultants, Inc.
Tiffany King Asbestos Group Manager TDSHS Asbestos Consultant License No. 10-5816
Greg Calhoun Senior Associate Department Manager - Asbestos, Lead & IH Services TDSHS Asbestos Consultant License No. 10-5510
DRAFT
mailto:mjh@enapayllc.com
Responsive ■ Resourceful ■ Reliable
1.1 Project Objective
3.1 Visual Assessment
3.2 Physical Assessment
3.3 Sample Collection
3.4 Sample Analysis
APPENDIX A CONFIRMED ASBESTOS-CONTAINING MATERIALS
APPENDIX B ASBESTOS SURVEY SAMPLE SUMMARY
APPENDIX C ASBESTOS ANALYTICAL LABORATORY DATA
APPENDIX D SITE PHOTOGRAPHS
APPENDIX E SAMPLE LOCATION DRAWING
APPENDIX F LICENSES
Responsive ■ Resourceful ■ Reliable 1
ASBESTOS SURVEY REPORT
Proposed VA Hospital Garland – Three Buildings
2300 Marie Curie Boulevard
INTRODUCTION
Terracon Consultants, Inc. (Terracon) conducted an asbestos survey at the site of the proposed VA Hospital Garland located at 2300 Marie Curie Boulevard, 700 Walter Reed Boulevard, and 900 North Shiloh Road in Garland, Texas. The survey was conducted June 10-19, 2019 by a team of Texas Department of State Health Services (TDSHS) licensed asbestos inspectors and asbestos consultants in general accordance with Terracon Proposal No. P94197779 dated June 6, 2019.
Accessible interior and exterior building components were surveyed and homogeneous areas of suspect asbestos-containing materials (ACM) were visually identified and documented. Although reasonable effort was made to survey accessible suspect materials, additional suspect but unsampled materials could be located in walls, in voids or in other concealed areas. Suspect ACM samples were collected in general accordance with the sampling protocols outlined in Environmental Protection Agency (EPA) regulation 40 CFR 763, the Asbestos Hazard Emergency Response Act (AHERA).
1.1 Project Objective
The objective of the asbestos survey was to identify the presence and location of accessible friable and nonfriable ACM present on the interior and exterior of the five-story main hospital structure (2300 Marie Curie Boulevard), a four-story medical plaza (700 Walter Reed Boulevard), and a single-story storage building (900 North Shiloh Road) in Garland, Texas.
The Texas Asbestos Health Protection Rules (TAHPR) and EPA regulation 40 CFR 61, Subpart M, the National Emission Standards for Hazardous Air Pollutants (NESHAP) require that an asbestos survey be performed prior to renovation or demolition activities.
2300 Marie Curie Boulevard ■ Garland, Texas June 21, 2019 ■ Terracon Project No. 94197779
Responsive ■ Resourceful ■ Reliable 2
BUILDING DESCRIPTION
Main Hospital – 2300 Marie Curie Boulevard
Building Five-story hospital building with basement constructed circa 1970 with additions, including the plaza building, constructed circa 1975, 1999, and 2003
Total Area 167,236 square feet (sq. ft.)
Roof Multi-level roofing system finished with tar and gravel and rolled-on asphalt roofing
Exterior Walls Exterior finished insulation system, texture on concrete, texture on metal, and texture on concrete masonry unit (CMU) blocks
Interior Description
Occupied inpatient mental health clinic, offices, exam rooms, x-ray rooms, procedure rooms, operating rooms, pharmaceutical rooms, break rooms, conference rooms, corridors, restrooms, electrical rooms, mechanical rooms, elevator lobbies, and stairwells
Interior Walls Textured drywall, textured concrete, textured CMU, and wainscoting on drywall, wall covering on drywall, and ceramic tile on drywall
Interior Ceilings
Textured drywall and 2’x4’ and 2’x2’ lay-in ceiling tile suspended from a concrete deck; spray-on fireproofing was observed in various areas throughout the main hospital on the concrete deck and on the metal decks of the stairwells
Interior Floors Unfinished concrete, terrazzo, floor coating, resilient floor covering, vinyl floor tile, carpet, and ceramic tile on a concrete substrate
Survey Limitations/ Inaccessible Areas
The fourth and fifth floors were occupied by an inpatient mental health clinic; although the remaining areas of the building were vacant, a large number of rooms were locked or used as storage space and inaccessible. Various areas of the vacant spaces had limited or no lighting. Debris and remnant furnishings were observed in various vacant areas throughout the interior. Hard ceilings were installed in various areas throughout the interior.
Plaza Building – 700 Walter Reed Boulevard
Building Four-story, multi-tenant medical building attached to the main hospital building Total Area (Included with the main building) Roof Rubber membrane, rolled-on composition roofing material Exterior Walls Texture on concrete and texture on plaster
Interior Description
Offices, exam rooms, x-ray rooms, procedure rooms, operating rooms, break rooms, conference rooms, corridors, restrooms, electrical rooms, mechanical rooms, elevator lobbies, and stairwells
Interior Walls Textured drywall, textured concrete, textured CMU blocks, textured plaster, unfinished drywall, fiberglass reinforced panel on drywall, wall covering on drywall, and ceramic tile on drywall
Interior Ceilings
Textured drywall and 2’x4’ and 2’x2’ lay-in ceiling tile suspended from a concrete deck; spray-on fireproofing was observed on the concrete deck
Interior Floors Unfinished concrete, floor coating, resilient floor covering, vinyl floor tile, raised flooring, carpet, and ceramic tile on a concrete substrate
Survey Limitations/ Inaccessible Areas
Multiple medical suites located in various areas of the building were occupied and operational at the time of the survey. The tenants of the occupied suites did not allow full access and no access was granted to the final suite until after the balance of the building had been completed. Although the remaining areas of the building were vacant, a large portion of the rooms were locked or used as storage space and inaccessible. Various areas of the vacant spaces had limited or no lighting. Debris and remnant furnishings were observed in various vacant areas throughout the interior. Hard ceilings were installed in various areas throughout the interior.
Responsive ■ Resourceful ■ Reliable 3
Storage Building – 900 North Shiloh Road
Building Single-story medical building constructed circa 1968 Total Area 19,881 sq. ft.
Roof Tar and gravel roofing system Exterior Walls Texture on concrete and CMU blocks Interior Description
Reception, exam rooms, offices, meeting rooms, conference rooms, corridors, restrooms, boiler room, electrical room, warehouse, and shipping/receiving
Interior Walls Textured concrete, textured drywall, wall covering on drywall, ceramic tile on drywall, and fiberglass reinforced panel on drywall
Interior Ceilings
2’ x 4’ lay-in ceiling tile system suspended from a concrete deck; spray-on fireproofing was not observed on the concrete deck
Interior Floors Epoxy floor coating, vinyl floor tile, carpet, and ceramic tile on a concrete substrate and unfinished concrete
Survey Limitations/ Inaccessible Areas
The vacant building is currently being used for storage; debris and remnant furnishings were observed throughout the interior. Exam Room 101, the janitorial closet, and the dark room were locked and inaccessible.
FIELD ACTIVITIES
The survey was conducted by the following TDSHS licensed asbestos consultants and inspectors:
◼ Mr. Marshall Rhodes, TDSHS Asbestos Consultant (License No. 10-5826) ◼ Mr. Matthew Mooney, TDSHS Asbestos Consultant (License No.10-5740), ◼ Ms. Tiffany King, TDSHS Asbestos Consultant (License No. 10-5816) ◼ Mr. Chad Champagne, TDSHS Asbestos Inspector (License No. 60-3112) ◼ Mr. Mike Smith, TDSHS Asbestos Inspector (License No. 60-3715), ◼ Mr. Tyler Daniels, TDSHS Asbestos Inspector (License No. 60-3755), ◼ Mr. George Slay, TDSHS Asbestos Inspector (License No. 60-2751), ◼ Mr. Keith Ebner, TDSHS Asbestos Inspector (License No. 60-3160), ◼ Mr. Tyler Hennigan, TDSHS Asbestos Inspector (License No. 60-3199), ◼ Mr. Enrique Castro, TDSHS Asbestos Inspector (License No. 60-3713), and ◼ Mr. Andrew Cassidy, TDSHS Asbestos Inspector (License No. 60-3726).
Copies of the asbestos consultants’ and inspectors’ licenses are attached in Appendix F. The survey was conducted in general accordance with the sample collection protocols established in EPA regulation 40 CFR 763, the AHERA. A summary of survey activities is provided below.
Responsive ■ Resourceful ■ Reliable 4
3.1 Visual Assessment
Our survey activities began with visual observation of the interior and exterior of each building to identify homogeneous areas (HA) of suspect ACM. A HA consists of building materials that appear similar throughout in terms of color, texture and date of application. The assessment was conducted throughout visually accessible areas of each building. Building materials identified as concrete, glass, wood, masonry, metal or rubber were not considered suspect ACM.
Terracon made reasonable efforts to assess suspect materials on the interior and exterior of each building; however, the following limitations were encountered at the time of the survey:
◼ Locked rooms throughout the interior of each building/availability of keys from CBRE, property management, CBRE did not have access to several key-pad doors, ◼ Expedited schedule/access limited to building security’s schedule, ◼ Vacant areas of each building used for storage of or littered with remnant furnishings, ◼ Operational mental health clinic on the fourth and fifth floors of the main building, and ◼ Multiple occupied medical clinics in the plaza building.
Due to these limitations, access to multiple areas in each building was limited and the potential exists for additional suspect ACM or quantities of identified ACM to be present in these inaccessible areas.
Terracon assessed multiple areas above the drywall and lay-in ceiling systems in each building, where possible, but did not observe additional suspect ACM except where noted in this report;
however; due to occupancy, building condition, and building usage at the time of the survey, access to areas above the ceiling was limited and the potential exists for additional suspect ACM or quantities of identified ACM to be present in these inaccessible areas.
Terracon lifted floor coverings in several areas in each building, where possible, but did not observe additional floor coverings/layers except where noted in this report; however, as Terracon could not assess beneath all floor coverings in all areas, there may be isolated areas of additional suspect ACM or quantities of identified ACM present beneath existing covering.
Terracon observed mirrors in the restrooms of each building that appeared to be mechanically fastened; however, the potential exists for suspect ACM mirror mastic to be located behind the mechanically fastened mirrors. Terracon attempted to assess the area behind the installed mirrors for suspect ACM; however, the presence or absence of suspect materials could not be verified without forcibly removing the installed mirrors, potentially causing excessive damage to the mirrors
Responsive ■ Resourceful ■ Reliable 5 and creating a safety hazard. If encountered, suspect ACM mirror mastic should be sampled prior to disturbance if it will be impacted by the renovation.
Terracon assessed multiple areas of the crawlspace, where possible, but did not observe additional suspect ACM materials except where noted in this report; however, due to the condition of the crawlspace, access was limited to the standing areas and the potential exists for additional suspect ACM materials or quantities of identified ACM to be present in these inaccessible areas.
3.2 Physical Assessment
A physical assessment of each homogeneous area of suspect ACM was conducted to assess the friability and condition of the materials. A friable material is defined by the EPA as a material which can be crumbled, pulverized or reduced to powder by hand pressure when dry. Friability was assessed by physically touching suspect materials.
3.3 Sample Collection
Based on results of the visual observation, bulk samples of suspect ACM were collected in general accordance with AHERA sampling protocols. Random samples of suspect materials were collected from each HA observed. Sample team members collected bulk samples using wet methods as applicable to reduce the potential for fiber release. Samples were placed in sealable containers and labeled with unique sample numbers using an indelible marker.
The following Table presents the number of HAs of suspect ACM and the number of samples collect from each building:
Building Homogenous Areas of
Suspect ACM
Number of Samples
Collected
Main Hospital – 2300 Marie Curie Boulevard 298 1,004
Plaza Building – 700 Walter Reed Boulevard 322 1,073
Storage Building – 900 North Shiloh Road 49 169
A summary of suspect ACM samples collected during the survey is included in Appendix B.
Drawings depicting sample locations and ACM locations are provided in Appendix E.
Responsive ■ Resourceful ■ Reliable 6
3.4 Sample Analysis
Suspect ACM samples were delivered under proper chain of custody to Cates Laboratories of Dallas, Texas, a National Voluntary Laboratory Accreditation Program accredited (Lab No.
200569-0) and TDSHS licensed (License No. 30-0287) laboratory for analysis by Polarized Light Microscopy (PLM) with dispersion staining techniques per EPA Method 600/R-93/116. The percentage of asbestos, where applicable, was determined by microscopic visual estimation.
REGULATORY OVERVIEW
The State of Texas has established the TAHPR which requires any asbestos-related activity to be performed by an individual licensed by the State of Texas, through the TDSHS. An asbestos related activity consists of the disturbance (whether intentional or unintentional), removal, encapsulation, or enclosure of asbestos, including preparations or final clearance, the performance of asbestos surveys, the development of management plans and response actions, asbestos project design, the collection or analysis of asbestos samples, monitoring for airborne asbestos, bidding for a contract for any of these activities, or any other activity required to be licensed under TAHPR.
Abatement must be performed by a State of Texas licensed asbestos abatement contractor in accordance with a project design prepared by a State of Texas licensed asbestos consultant. In addition, third party air monitoring must be conducted during the abatement activities.
The asbestos NESHAP (40 CFR Part 61 Subpart M) regulates asbestos fiber emission and asbestos waste disposal practices. It also requires the identification and classification of existing building materials prior to demolition or renovation activity. Under NESHAP, asbestos containing building materials are classified as either friable, Category I nonfriable or Category II nonfriable ACM. Friable materials are those that, when dry, may be crumbled, pulverized or reduced to powder by hand pressure. Category I nonfriable ACM includes packing, gaskets, resilient floor coverings and asphalt roofing products containing more than 1% asbestos. Category II nonfriable ACM are any materials other than Category I materials that contain more than 1% asbestos.
Friable ACM, Category I and II nonfriable ACM in poor condition and has become friable or which will be subject to drilling, sanding, grinding, cutting, or abrading and which could be crushed or pulverized during anticipated renovation or demolition activities are considered regulated ACM (RACM). The TAHPR and NESHAP require that written notification be submitted before beginning renovation projects which include the disturbance of any asbestos-containing material (ACM) in a building or facility, or before the demolition of a building or facility, even when no asbestos is present. This written notification must be provided to the TDSHS at least 10 working days prior to the commencement of asbestos abatement or demolition activities. Removal of
Responsive ■ Resourceful ■ Reliable 7
RACM must be conducted by a State of Texas licensed asbestos contractor. In addition, third party air monitoring must be performed during the abatement.
The Occupational Safety and Health Administration (OSHA) Asbestos standard for the construction industry (29 CFR 1926.1101) regulates workplace exposure to asbestos. The OSHA standard requires employee exposure to airborne asbestos fibers be maintained below 0.1 asbestos fibers per cubic centimeter of air (0.1 f/cc).
The OSHA standard classifies construction and maintenance activities which could disturb ACM and specifies work practices and precautions which employers must follow when engaging in each class of regulated work.
FINDINGS AND RECOMMENDATIONS
Based on the results of the laboratory analyses, asbestos was confirmed in the following materials:
Building A (Main Hospital)
Roof and Exterior
◼ Exterior Duct Sealant (gray) East ◼ Exterior Texture on Concrete (tan, rough)
Basement
◼ 12” x 12” Floor Tile (beige with gray and black streaks) with Mastic (black) ◼ Texture on Concrete (tan) ◼ 12” x 12” Floor Tile (tan) with Mastic (black) ◼ Concrete Masonry Unit (CMU) Texture (tan) ◼ Duct Sealant (black) on 24” Pipe ◼ 12” x 12” Floor Tile (green) with Mastic (black) ◼ Boiler Gasket (brown) ◼ Duct Sealant (black) on Square Ductwork
First Floor
◼ Sink Undercoat (gray) ◼ Mastic (black) with 12” X 12” Floor Tile (off-white, gray specks) ◼ Duct Sealant (white) ◼ Residual Thinset (gray) ◼ 12” X 12” Floor tile (gray, white streaks) with Mastic (black) ◼ 12” X 12” Floor tile (tan, gray and red streaks) with Mastic (black) ◼ Thinset with 1” X 1” Ceramic Floor Tile Grout (gray) Multi-Color
Responsive ■ Resourceful ■ Reliable 8
◼ Thinset with 5” X 5” Ceramic Wall Tile Grout (white) Multi-color ◼ Mastic (black) with 12” X 12” Floor Tile (white, black specks)
2nd Floor
◼ Interior Texture CMU Block (off-white) ◼ Weatherproofing (black)
4th & 5th Floors
◼ Finished Drywall Wall System (beige, semi-smooth)
Stairwells
◼ Interior Concrete Texture (cream, semi-smooth) ◼ Textured CMU Block (cream) ◼ FirepProofing (grey, tan)
Plaza Building – 700 Walter Reed Boulevard
Basement
◼ Fitting Gasket (gray) on Medical Vacuum Air Compressor
3rd Floor
◼ Interior Window Caulk (black) Associated w/Metal Frames
Storage Building – 900 North Shiloh Road
◼ Exterior Building Caulk (white) associated w/Metal Parapet Cap ◼ Black Weatherproofing Material associated w/Parapet Wall ◼ Exterior Building Caulk (light grey) associated w/Corrugated Sheet Metal ◼ Exterior Door Caulk (grey) ◼ Texture on CMU (multi-color) ◼ Interior Concrete Texture (white, semi-smooth) ◼ Wall Covering (black/gold vertical lines) on Drywall ◼ Black Mastic beneath Epoxy Floor Coating (light grey) ◼ Carpet Mastic (black) ◼ Mastic (black) with 12" X 12" Vinyl Floor beneath Carpet Mastic (tan) ◼ Mastic Black beneath 12" X 12" Ceramic Floor Tile (dark grey/green, faux slate)/Grout (grey) & Thinset
The identified ACM gray fireproofing observed in the Main Building Stairwells was assessed to be friable but in good condition on the day of the survey.
Responsive ■ Resourceful ■ Reliable 9
The remaining identified ACM collected from the three structures were assessed to be nonfriable and in good condition on the day of the survey. Terracon understands that the building surveyed is scheduled for future renovation or demolition. Therefore, the identified interior ACM should be abated prior to activities that will disturb the identified ACM.
The following samples were determined by PLM visual estimation to contain <1% Chrysotile asbestos:
◼ Main Building-Basement, Samples 81-83 Texture on concrete ◼ Main Building-First Floor, Samples 171-173 Residual thinset ◼ Main Building-First Floor, Samples 260-262 Ceramic floor tile thinset ◼ Main Building-First Floor, Samples 263-265 Ceramic wall tile thinset
USEPA NESHAP regulations and the TAHPR require that materials determined by PLM analysis with results greater than zero but less than 10% asbestos be reanalyzed using the more quantitative point counting technique or that the material be considered ACM and subject to NESHAP regulations and the TAHPR. Terracon recommends Samples 81-83, 171-173, 260-262, and 263-265 be re-submitted for point count analysis.
The asbestos abatement must be performed by a TDSHS licensed asbestos contractor in accordance with a project design prepared by a TDSHS licensed asbestos consultant. In addition, third party air monitoring must be performed during the abatement.
It is important to note the TAHPR and NESHAP require that written notification be submitted before beginning renovation projects which include the disturbance of any ACM in a building or facility, or before the demolition of a building or facility, even when no asbestos is present. This written notification must be provided to the TDSHS at least 10 working days prior to the commencement of asbestos abatement or demolition activities. These activities must be performed in accordance with the current TDSHS, EPA, and OSHA guidelines.
Responsive ■ Resourceful ■ Reliable 10
GENERAL COMMENTS
This asbestos survey was conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings, conclusions and recommendations expressed in this report are based on conditions observed during our survey of the subject buildings. The information contained in this report is relevant to the date on which this survey was performed, and should not be relied upon to represent conditions at a later date. This report has been prepared on behalf of and exclusively for use by Enapay, LLC for specific application to their project as discussed. This report is not a bidding document. Contractors or consultants reviewing this report must draw their own conclusions regarding further investigation or remediation deemed necessary. Terracon does not warrant the work of regulatory agencies, laboratories or other third parties supplying information which may have been used in the preparation of this report. No warranty, express or implied is made.
APPENDIX A
CONFIRMED ASBESTOS-CONTAINING MATERIALS
Proposed VA Hospital Garland – Three Buildings
2300 Marie Curie Boulevard
Sample
No.
Material Location (Area)
NESHAP
Classification
Assessed
Condition1
Estimated
Quantity2
Building A (Main Hospital) – Roof and Exterior
24, 25, 26 Exterior Duct Sealant (gray) East Tower roof Category II Nonfriable
Good 75 ln. ft.
54, 55, 56, 57, 58
Exterior Texture on Concrete (tan, rough) West Tower facade
Category II Nonfriable
Good 2,500 sq. ft.
Building A (Main Hospital) – Basement
75, 76, 77 12” x 12” Floor Tile (beige with gray and black streaks) with
Mastic (black) West Corridor
Category I Nonfriable
Good 584 sq. ft.
78, 79, 80, 81, 82, 83, Texture on Concrete (tan)
West corridor, north corridor, mechanical rooms, boiler room, shipping/receiving, stairwells
Category II Nonfriable
Good 4,114 sq. ft.
88, 89, 90 12” x 12” Floor Tile (tan) with
Mastic (black) West Corridor Category I Nonfriable
Good 64 sq. ft.
118, 119, 120, 121, 122, 123, Concrete Masonry Unit (CMU) Texture (tan)
West corridor, north corridor, mechanical rooms, boiler room, shipping/receiving, stairwells
Category II Nonfriable
Good 5,513 sq. ft. DRAFT
Proposed VA Hospital Garland – Three Buildings
2300 Marie Curie Boulevard
Material Location (Area)
NESHAP
Classification
Assessed
Condition1
Estimated
Quantity2
164, 165, Duct Sealant (black) on 24” Pipe Environmental services rooms
Category II Nonfriable
Good 90 ln. ft.
188, 189, 12” x 12” Floor Tile (green) with Mastic (black) West Corridor
Category I Nonfriable
Good 626 sq.ft.
215, 216, 217 Boiler Gasket (brown) Boiler room
Category I Nonfriable
Good 20 sq. ft.
218, 219, Duct Sealant (black) on Square Ductwork
Storage closet north of crawl space
Category II Nonfriable
Good 150 ln. ft.
Building A (Main Hospital) – First Floor
69, 70, 71 Sink Undercoat (gray) Various rooms throughout the first floor
Category II Nonfriable
Good 9 sinks
135, 136, Mastic (black) with 12” X 12” Floor tile (off-white, gray specks) Nuclear medicine Category I Nonfriable
Good 576 sq. ft.
147, 148, Duct Sealant (white) Corridor outside Nuclear Medicine
Category II Nonfriable
Good 8 ln. ft.
171, 172, Residual Thinset (gray) Decontamination Category II
Good 126 ln. ft. DRAFT
Proposed VA Hospital Garland – Three Buildings
2300 Marie Curie Boulevard
Material Location (Area)
NESHAP
Classification
Assessed
Condition1
Estimated
Quantity2
190, 191, 12” X 12” Floor tile (gray, white streaks) with Mastic (black) Decontamination Category I Nonfriable
Good 664 sq. ft.
257, 258, 12” X 12” Floor tile (tan, gray and red streaks) with Mastic (black) Pulmonary Lab patient rooms Category I Nonfriable
Good 2,376 sq. ft.
260, 261, Thinset with 1” X 1” Ceramic Floor
Tile Grout (gray) Multi-Color Cath Lab Category II Nonfriable
Good 252 sq. ft.
263, 264, Thinset with 5” X 5” Ceramic Wall
Tile Grout (white) Multi-color Cath Lab Category II Nonfriable
Good 1,456 sq. ft.
266, 267, Mastic (black) with 12” X 12” Floor tile (white, black specks) Cath Lab patient rooms Category I Nonfriable
Good 2,916 sq. ft.
Building A (Main Hospital) – 2nd Floor
64, 65, 66 Interior Texture CMU Block (off-white)
Mechanical room Category II Nonfriable
Good 500 sq. ft.
97, 98, 99 Weatherproofing (black) Central patient elevator lobby
Category I Nonfriable
Good 100 sq. ft.
Building A (Main Hospital) – 4th & 5th Floors
4, 5, 6, 7, 8, 9, 10
Finished Drywall Wall System (beige, semi-smooth) Throughout
Category II Nonfriable
Good 165,000 sq.
ft. DRAFT
Proposed VA Hospital Garland – Three Buildings
2300 Marie Curie Boulevard
Material Location (Area)
NESHAP
Classification
Assessed
Condition1
Estimated
Quantity2
Building A (Main Hospital) – Stairwells
S-14, 15, 16, 17, Interior Concrete Texture (cream, semi-smooth) Stairwells E2 and 1W
Category II Nonfriable
Good 3,200 sq. ft.
S-21, 22, 23, 24, 25, 26, 27 Textured CMU Block (cream) Stairwell 1W
Category II Nonfriable
Good 4,800 sq. ft.
S-31, 32, 33, 34, 35 Fireporoofing (grey, tan) Stairwells E1 and 1W Friable Good 980 sq. ft.
Plaza Building – 700 Walter Reed Boulevard
Plaza 1 – Basement
96, 97, 98 Fitting Gasket (gray) on Medical Vacuum Air Compressor Mechanical room
Category I Nonfriable
Good 2 gaskets
Plaza 1 – 3rd Floor
23, 24, 25 Interior Window Caulk (black) Associated w/Metal Frames Throughout
Category II Nonfriable
Good 510 ln. ft.
Storage Building – 900 North Shiloh Road
7, 8, 9 Exterior Building Caulk (white) associated w/Metal Parapet Cap Roof parapet cap Category II
Good 120 ln. ft. DRAFT
Proposed VA Hospital Garland – Three Buildings
2300 Marie Curie Boulevard
Material Location (Area)
NESHAP
Classification
Assessed
Condition1
Estimated
Quantity2
21, 22, 23 Black Weatherproofing Material associated w/Parapet Wall Roof parapet walls
Category I Nonfriable
Good 120 sq. ft.
30, 31, 32 Exterior Building Caulk (light grey) associated w/Corrugated Sheet Metal
Loading bay roof Category II Nonfriable
Good 25 ln. ft.
39, 40, 41 Exterior Door Caulk (grey) Exterior at entry Category II Nonfriable
Good 34 ln.ft.
42, 43, 44, 45, 46
Texture on CMU (multi-color) Exterior at loading bay Category II Nonfriable
Good 480 sq. ft.
70, 71, 72, 73, 74
Interior Concrete Texture (white, semi-smooth) Storage area
Category II Nonfriable
Good 1,100 sq. ft.
104, 105, Wall Covering (black/gold vertical lines) on Drywall Restrooms
Category II Nonfriable
Good 1,300 sq. ft.
134, 135, Black Mastic beneath Epoxy Floor Coating (light grey) Storage area
Category I Nonfriable
Good 2,500 sq. ft.
152, 153, Carpet Mastic (black) Offices, common areas, work rooms, medical records, exam rooms
Category I
Good 8,800 sq. ft. DRAFT
Proposed VA Hospital Garland – Three Buildings
2300 Marie Curie Boulevard
Material Location (Area)
NESHAP
Classification
Assessed
Condition1
Estimated
Quantity2
155, 156, Mastic (black) with 12" X 12" Vinyl Floor beneath Carpet Mastic (tan) Throughout
Category I Nonfriable
Good Included with Samples 155, 156, 157
167, 168, Mastic Black beneath 12" X 12" Ceramic Floor Tile (dark grey/green, faux slate)/Grout (grey) & Thinset
Reception Category I Nonfriable
Good 800 sq. ft.
1Denotes condition – Legend: G-Good, D-Damaged, SD-Significantly Damaged 2ln. ft. = linear feet sq. ft. = square feet 2 Due to limited access and inaccessible areas, the quantities of ACM listed may increase.
APPENDIX B
ASBESTOS SURVEY SAMPLE SUMMARY
Proposed VA Hospital Garland – Three Buildings
2300 Marie Curie Boulevard
Material Asbestos
Containing
Sample
Numbers
Main Hospital – 2300 Marie Curie Boulevard
Building A (Main Hospital) – Roof and Exterior
Tar & Gravel Membrane (black) No 1, 2, 3 Roof Flashing (gray) No 4, 5, 6
Exterior Building Caulk (gray) on Parapet Cap No 7, 8, 9 Exterior Finished Insulation System (tan) No 10, 11, 12, 13, 14
Roof Cement (black) No 15, 16, 17 Exterior Building Caulk (tan) No 18, 19, 20
Exterior Building Caulk (off-white) No 21, 22, 23 Exterior Duct Sealant (gray) Yes 24, 25, 26
Exterior Sealant (white) on Thermal System Insulation No 27, 28, 29
Exterior Fire Stop (red) No 30, 31, 32 Exterior Building Caulk (black) No 33, 34, 35 Exterior Building Caulk (gray) No 36, 37, 38
Rolled-On Roofing Membrane (gray) No 39, 40, 41 Roof Flashing (gray) No 42, 43, 44
Exterior Duct Sealant (gray) No 45, 46, 47 Exterior Duct Sealant (gray) No 48, 49, 50
Exterior Building Caulk (black) No 51, 52, 53 Exterior Texture on Concrete (tan, rough) Yes 54, 55, 56, 57, 58
Exterior Building Caulk (off-white) No 59, 60, 61 Exterior Building Caulk (tan) No 62, 63, 64
Rolled-On Roofing Membrane (gray) No 65, 66, 67 Roof Flashing (gray) w/Silver Paint No 68, 69, 70
Exterior Duct Sealant (white) No 71, 72, 73 Exterior Building Caulk (tan) No 74, 75, 76
Exterior Finished Insulation System (tan) No 77, 78, 79, 80, 81, 82, 83
Exterior Building Caulk (gray) No 84, 85, 86 Exterior Duct Sealant (brown) No 87, 88, 89
Proposed VA Hospital Garland – Three Buildings
2300 Marie Curie Boulevard
Containing
Sample
Numbers
Rolled-On Roofing Membrane (black) No 90, 91, 92 Roof Flashing (gray) No 93, 94, 95 Roof Flashing (tan) No 96, 97, 98
Roof Flashing (black) No 99, 100, 101 Roof Cement (black) No 102, 103, 104
Exterior Texture on Metal (tan) No 105, 106, 107, 108, 109
Exterior Finished Insulation System (tan) No 110, 111, 112, 113, 114, 115, Exterior Building Caulk (gray) No 117, 118, 119 Exterior Duct Sealant (white) No 120, 121, 122
Exterior Texture on Concrete (tan) No 123, 124, 125, 126, 127
Exterior Weatherproofing (black) No 128, 129, 130 Exterior Texture on Concrete Masonry Unit (CMU)
(multi-color) No 131, 132, 133, 134, 135
Exterior Building Caulk (black) on Windows No 136, 137, 138 Exterior Building Caulk (gray) on Doors No 139, 140, 141
Thermal System Insulation Mastic (black) No 142, 143, 144 Pipe Gasket (black) No 145, 146, 147
Exterior Expansion Joint Caulk (gray) No 148, 149, 150 Building A (Main Hospital) – Basement
2' X 2' Ceiling Tile (white, rough) No 1, 2, 3 Finished Drywall Wall System (multi-color, semi-smooth) No 4, 5, 6, 7, 8, 9, 10, 11, 12
Cove Base Mastic (tan) No 13, 14, 15 12” x 12” Floor Tile (tan with beige &gray specks) with Mastic (yellow) No 16, 17, 18
4" X 4" Ceramic Wall Tile Grout (white) & Thinset (gray) No 19, 20, 21
Proposed VA Hospital Garland – Three Buildings
2300 Marie Curie Boulevard
Containing
Sample
Numbers
6" X 6" Ceramic Floor Tile Grout (grey) & Thinset (grey) No 22, 23, 24
Interior Building Caulk (white) No 25, 26, 27 Finished Drywall Ceiling System (tan, semi-smooth) No 28, 29, 30, 31, 32 12” x 12” Floor Tile (beige tile, tan tile, blue tile, and red tile pattern) with Mastic (yellow) No 33, 34, 35
Carpet Mastic (yellow) No 36, 37, 38 Sink Undercoat (black) No 39, 40, 41
Multi-size Ceramic Floor Tile Grout (gray) with Thinset (gray) No 42, 43, 44
Floor Coating (red) No 45, 46, 47 2' X 2' Ceiling Tile (white, indents) No 48, 49, 50
Stair Tread Mastic (yellow) No 51, 52, 53 Duct Sealant (gray) No 54, 55, 56
Thermal System Insulation Sealant (white) No 57, 58, 59 Fire Stop (red) No 60, 61, 62
Spray-on Fireproofing (gray) No 63, 64, 65 12" X 12" Ceramic Floor Tile Grout (grey) & Thinset
(grey) No 66, 67, 68
5" X 5" Ceramic Wall Tile Grout (tan) & Thinset (gray) No 69, 70, 71
Floor Covering (gray with black specks) No 72, 73, 74 12” x 12” Floor Tile (beige with gray and black streaks) with Mastic (black) Yes
(black mastic) 75, 76, 77
Texture on Concrete (tan) Yes
(<1%)
78, 79, 80, 81, 82, 83, 84
6” Cove Base Mastic (tan) No 85, 86, 87
12” x 12” Floor Tile (tan) with Mastic (black) Yes
(black mastic) 88, 89, 90
12” x 12” Floor Tile (tan and gray mottled) with Mastic (yellow) No 91, 92, 93
2' X 4' Ceiling Tile (white, pinholes and gouges) No 94, 95, 96
Proposed VA Hospital Garland – Three Buildings
2300 Marie Curie Boulevard
Containing
Sample
Numbers
2' X 4' Ceiling Tile (white, pinholes and fissures) No 97, 98, 99 2' X 2' Ceiling Tile (white, pinholes and indents) No 100, 101, 102 Finished Drywall Wall System (multi-color, drag) No 103, 104, 105
12” x 12” Floor Tile (tan tile and beige tile pattern) with Mastic (yellow) No 106, 107, 108
Wainscot Mastic (tan) No 109, 110, 111 Stair Tread Mastic (brown, yellow) No 112, 113, 114
Cove Base Mastic (brown) No 115, 116, 117
Concrete Masonry Unit (CMU) Texture (tan) Yes
118, 119, 120, 121, 122, 123, Interior Building Caulk (gray) at door No 125, 126, 127
Interior Building Caulk (off-white) at staircase No 128, 129, 130 Floor Covering (tan) No 131, 132, 133
2' X 2' Ceiling Tile (white, smooth) No 134, 135, 136 2' X 2' Ceiling Tile (white, pinholes, and pockmarks No 137, 138, 139
2’ x 2’ Floor Tile (tan) with Mastic (yellow) No 140, 141, 142 Floor Coating (gray) No 143, 144, 145
Fire Stop (brown) No 146, 147, 148 Thermal Pipe Insulation (white) No 149, 150, 151
Thermal Fitting Insulation (white) No 152, 153, 154 Duct Sealant (gray) No 155, 156, 157
12” x 12” Floor Tile (tan mottled) with Mastic (yellow) No 158, 159, 160 Weatherproofing (black) No 161, 162, 163
Duct Sealant (black) on 24” Pipe Yes 164, 165, 166 2” X 2” Ceramic Floor Tile Grout (beige) and Thinset
(beige) No 167, 168, 169
4" X 4" Ceramic Wall Tile Grout (white) & Mastic (yellow) No 170, 171, 172
Resilient Sheet Flooring (wood pattern) No 173, 174, 175 12” x 12” Floor Tile (tan and beige blend) with Mastic
(gray) No 176, 177, 178
Proposed VA Hospital Garland – Three Buildings
2300 Marie Curie Boulevard
Containing
Sample
Numbers
Finished Drywall Wall System (tan, smooth) No 179, 180, 181 Residual Floor Mastic (yellow) No 182, 183, 184
Button Mastic (tan) No 185, 186, 187
12” x 12” Floor Tile (green) with Mastic (black) Yes
(both) 188, 189, 190
4" X 4" Ceramic Wall & Floor Tile Grout (brown) & Thinset (gray) No 191, 192, 193
Floor Tile Under Carpet with Mastic (Yellow) No 194, 195, 196 6" X 6" Ceramic Wall Tile Grout (tan) & and Thinset
(white) No 197, 198, 199
12” x 12” Floor Tile (beige tile, tan tile, blue tile, and red tile pattern; multi-layer) with Mastic (black) No 200, 201, 202
12” x 12” Floor Tile (tan with gold streaks) with Mastic (black) No 203, 204, 205
Thermal System Insulation (white) No 206, 207, 208 Boiler Door Insulation (white) No 209, 210, 211
Boiler Insulation (gray, interior) No 212, 213, 214 Boiler Gasket (brown) Yes 215, 216, 217
Duct Sealant (black) on Square Ductwork Yes 218, 219, 220 Building A (Main Hospital) – First Floor
Finished Drywall Wall System (multi-color, drag) No
1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20
2' X 2' Ceiling Tile (white, rough) No 21, 22, 23 6” Cove Base Mastic (tan) No 24, 25, 26
12” x 12” Floor Tile (tan tile and beige tile pattern) with Mastic No 27, 28, 29
Spray-on Fireproofing (gray) No 30, 31, 32, 33, 34 Carpet Mastic (yellow) No 35, 36, 37
Fire Stop (red) No 38, 39, 40 Thermal System Insulation Mastic (white) No 41, 42, 43
Proposed VA Hospital Garland – Three Buildings
2300 Marie Curie Boulevard
Containing
Sample
Numbers
Floor tile and Mastic (yellow) beneath Carpet No 44, 45, 46 Duct Sealant (gray) No 47, 48, 49
12” X 12” Ceramic Floor Tile Grout (gray) and
Thinset (gray) No 50, 51, 52
Finished Drywall Ceiling System (white, semi-smooth) No 53, 54, 55, 56, 57, 58, 59 8" X 8" Ceramic Floor/Wall Tile Grout (grey) &
Thinset (grey) No 60, 61, 62
Resilient Sheet Flooring (wood pattern) with Mastic (Yellow) No 63, 64, 65
12” x 12” Floor Tile (tan mottled) with Mastic (yellow) No 66, 67, 68 Sink Undercoat (gray) Yes 69, 70, 71
Unfinished Drywall/Joint Compound No 72, 73, 74 Fire Stop (white) No 75, 76, 77
Texture on Concrete (white, rough) No 78, 79, 80 2' X 2' Ceiling Tile (white, pinholes and indents) No 81, 82, 83
Interior Building Caulk (black) associated w/ 2” x 2” Ceramic Wall Tile No 84, 85, 86
Fiberglass Reinforced Panel Mastic (tan) No 87, 88, 89 2' X 2' Ceiling Tile (white, pinholes and fissures) No 90, 91, 92
Sink Undercoat (white) No 93, 94, 95 Rectangle Ceramic Floor Tile Grout (gray) with
Thinset (gray) No 96, 97, 98
12” X 12” Floor tile (blue, tan specks) with Mastic
(yellow) No 99, 100, 101
Wall Covering (multi-color) Drywall/Joint Compound No 102, 103, 104 2” X 2” Ceramic Floor Tile Grout (gray) and Thinset
(gray) No 105, 106, 107
Multi-size Ceramic Wall Tile Grout (white) with Thinset No 108, 109, 110
2' X 4' Ceiling Tile (white, pinholes and horizontal fissures) No 111, 112, 113 DRAFT
Proposed VA Hospital Garland – Three Buildings
2300 Marie Curie Boulevard
Responsive ■ Resourceful ■ Reliable 7
Containing
Sample
Numbers
Resilient Sheet Flooring (gray, red specks) with Mastic No 114, 115, 116
2' X 4' Ceiling Tile (white, pinholes and longitudinal fissures) No 117, 118, 119
Raised Floor Mastic (black) No 120, 121, 122 Sink Undercoat (black) No 123, 124, 125
12” X 12” Floor tile (gray mottled) with Mastic (yellow) No 126, 127, 128
Resilient Sheet Flooring (brown) with Mastic No 129, 130, 131 2' X 4' Ceiling Tile (white, pinholes and indents) No 132, 133, 134 12” X 12” Floor tile (off-white, gray specks) with
Mastic (black) Yes
(black mastic) 135, 136, 137
12” X 12” Floor tile (blue/tan mottled) with Mastic
(yellow) No 138, 139, 140
12” X 12” Floor tile (beige/tan white specks) with
Mastic (yellow) No 141, 142, 143
Resilient Sheet Flooring (light blue) with Mastic No 144, 145, 146 Duct Sealant (white) Yes 147, 148, 149
2' X 2' Ceiling Tile (white, pinholes) No 150, 151, 152 Texture on Concrete (white, smooth) No 153, 154, 155
Multi-size Ceramic Wall Tile Grout (beige) with Thinset (off-white) No 156, 157, 158
12” X 12” Ceramic Floor Tile Grout (gray) and Thinset (gray) No 159, 160, 161
Resilient Sheet Flooring (gray, white streaks) with Mastic No 162, 163, 164
12” X 12” Ceramic Floor Tile Grout (gray) Marble
Pattern and Thinset (light gray) No 165, 166, 167
Cove Base Mastic (cream) No 168, 169, 170
Residual Thinset (gray) Yes
(<1%) 171, 172, 173
Unfinished Ceiling Plaster No 174, 175, 176 Cove Base Mastic (brown) No 177, 178, 179
Proposed VA Hospital Garland – Three Buildings
2300 Marie Curie Boulevard
Responsive ■ Resourceful ■ Reliable 8
Containing
Sample
Numbers
Finished Plaster Wall System (white, drag) No 180, 181, 182, 183, 184, 185, 1' X 1' Ceiling Tile (white, pinholes and fissures) w/Button Mastic (brown) applied to Unfinished
Plaster No 187, 188, 189
12” X 12” Floor tile (gray, white streaks) with Mastic
(yellow) Yes
(both) 190, 191, 192
2' X 2' Ceiling Tile (white, smooth) No 193, 194, 195
Finished Drywall Wall System (white, heavy drag) No 196, 197, 198, 199, 200, 201, Texture on CMU (multi-color) No 203, 204, 205, 206, 207
Finished Plaster Ceiling System (white, sandy) No 208, 209, 210, 211, 212
Rectangle Ceramic Wall Tile Grout (white) w/Thinset No 213, 214, 215 Resilient Sheet Flooring (light wood pattern) with
Mastic (Yellow) No 216, 217, 218
Resilient Sheet Flooring (multi-color cloud pattern) with Mastic (Yellow) No 219, 220, 221
1' X 1' Ceiling Tile (white, pinholes and indents) w/Button Mastic (brown) applied to Unfinished
Plaster No 222, 223, 224
Resilient Sheet Flooring (off-white, pink dots) with Mastic (Yellow) No 225, 226, 227
Resilient Sheet Flooring (multi-color, white specks) with Mastic (Yellow) No 228, 229, 230
2' X 2' Ceiling Tile (white, tiny pinholes) No 231, 232, 233 Resilient Sheet Flooring (gray mottled pattern) with
Mastic (Yellow) No 234, 235, 236
18” X 18” Ceramic Floor Tile Grout (gray) Marble and Thinset (gray) No 237, 238, 239 DRAFT
Proposed VA Hospital Garland – Three Buildings
2300 Marie Curie Boulevard
Responsive ■ Resourceful ■ Reliable 9
Containing
Sample
Numbers
12” X 12” Ceramic Wall Tile Grout (tan) Marble and
Thinset (gray) No 240, 241, 242
Spray-on Fireproofing (light gray) No 243, 244, 245, 246, 247
Fire Door Insulation (white) No 248, 249, 250 12” X 12” Floor tile (multi-color mottled) with Mastic
(yellow) No 251, 252, 253
Resilient Sheet Flooring (green) with Mastic (Yellow) No 254, 255, 256 12” X 12” Floor tile (tan, gray and red streaks) with
Mastic (yellow) Yes
(both) 257, 258, 259
1” X 1” Ceramic Floor Tile Grout (gray) Multi-Color w/Thinset
Yes
(<1%) 260, 261, 262
5” X 5” Ceramic Wall Tile Grout (white) Multi-color w/Thinset
Yes
(<1%) 263, 264, 265
12” X 12” Floor tile (white, black specks) with Mastic
(black) Yes
(black mastic) 266, 267, 268
2' X 4' Ceiling Tile (white, pinholes and little indents) No 269, 270, 271 Resilient Sheet Flooring (gray, specks) w/Mastic No 272, 273, 274 12” X 12” Floor tile (checked tan & beige mottled, gray/white specks) with Mastic (yellow/gray) No 275, 276, 277
Rectangle Ceramic Wall Tile Grout (gray) Marble Pattern w/Thinset (white) No 278, 279, 280
12” X 12” Ceramic Wall Tile Grout (tan) Marble and
Mastic (tan) No 281, 282, 283
Resilient Sheet Flooring (dark brown, wood pattern) w/Mastic No 284, 285, 286
Resilient Sheet Flooring (white, blue & gray specks) w/Mastic No 287, 288, 289
Brick Pattern Ceramic Wall Tile Grout (light gray) w/Thinset (white) No 290, 291, 292
Resilient Sheet Flooring (blue cloud pattern) with Mastic (Yellow) No 293, 294, 295
Resilient Sheet Flooring (black) with Mastic (Yellow) No 296, 297, 298
Proposed VA Hospital Garland – Three Buildings
2300 Marie Curie Boulevard
Responsive ■ Resourceful ■ Reliable 10
Containing
Sample
Numbers
Interior Building Caulk (black) No 299, 300, 301 Vapor Barrier Gypsum Board No 302, 303, 304
Building A (Main Hospital) – 2nd Floor
2' X 2' Ceiling Tile (white, rough) No 1, 2, 3 2' X 2' Ceiling Tile (white, pinhole & pockmark) No 4, 5, 6
Finished Drywall Wall System (multi-color, semi-smooth)
No 7, 8, 9, 10, 11, 12, 13
4" Cove Base (multi-color) & Mastic (cream) No 14, 15, 16 12" X 12" Vinyl Floor Tile (cream/purple, mottled) &
Mastic (yellow) No 17, 18, 19
4" X 36" Vinyl Floor Tile (tan, faux wood plank) & Mastic No 20, 21, 22
Carpet Mastic (yellow) No 23, 24, 25 Resilient Sheet Flooring (purple, diamond plate) No 26, 27, 28 Resilient Sheet Flooring (blonde, faux wood) on
Leveling Compound No 29, 30, 31
Interior Building Caulk (white) associated w/ICU Casework No 32, 33, 34
4" X 4" Ceramic Wall Tile (beige)/Grout (tan) & Mastic (tan) No 35, 36, 37
2" X 2" Ceramic Floor Tile (grey w/blue specks)/Grout (dark grey) & Thinset (grey) No 38, 39, 40
2' X 2' Ceiling Tile (white, pinhole & fissure) No 41, 42, 43 Finished Drywall Ceiling System (white, semi-smooth) No 44, 45, 46, 47, 48, 49, 50 Sink Undercoating (black) No 51, 52, 53
Interior Building Caulk (white) associated w/Plumbing No 54, 55, 56
Finished Drywall Wall System (cream/blue, smooth) No 57, 58, 59, 60, 61, 62, 63 Interior Textured CMU Block (off-white) Yes 64, 65, 66
Interior Textured Concrete (off-white, smooth) No 67, 68, 69 Resilient Sheet Flooring (tan, pebbled) - No 70, 71, 72
Proposed VA Hospital Garland – Three Buildings
2300 Marie Curie Boulevard
Responsive ■ Resourceful ■ Reliable 11
Containing
Sample
Numbers
Wall Covering (cream, woven) on Drywall No 73, 74, 75 12" X 12" Vinyl Floor Tile (white, w/black flakes) &
Mastic (yellow) No 76, 77, 78
Fiberglass Reinforced Panel Mastic (cream) No 79, 80, 81 8" X 8" Ceramic Floor Tile (light grey)/Grout (grey) &
Thinset (grey/blue) No 82, 83, 84
4" X 4" Ceramic Wall Tile (cream & green, checkered)/Grout (white) & Thinset (white) No 85, 86, 87
Sink Undercoating (light grey) No 88, 89, 90 Interior Window Caulk (black) No 91, 92, 93 Interior Window Caulk (white) No 94, 95, 96
Weatherproofing (black) Yes 97, 98, 99 Duct Mastic (dark gray) No 100, 101, 102
Building A – 3rd Floor
2' X 2' Ceiling Tile (white, rough) No 1, 2, 3 Finished Drywall Ceiling System (white, semi-smooth) No 4, 5, 6, 7, 8, 9, 10
Finished Drywall Wall System (off-white, semi-smooth)
No 11, 12, 13, 14, 15, 16, 17
4" Cove Base & Mastic (cream) No 18, 19, 20 3" X 36" Vinyl Floor Tile (blonde/red, faux wood plank) & Mastic (grey) No 21, 22, 23
Resilient Sheet Flooring (tan/grey, pebbled) No 24, 25, 26 12" X 12" Vinyl Floor Tile (tan & pebbled) & Mastic
(yellow) No 27, 28, 29
12" X 12" Vinyl Floor Tile (beige/tan, mottled) & Mastic (yellow) No 30, 31, 32
Interior Building Caulk (tan/off-white) associated w/Casework No 33, 34, 35
Sink Undercoating (black) No 36, 37, 38 Interior Window Caulk (white) No 39, 40, 41
4" X 4" Ceramic Wall Tile (off-white)/Grout (white) & Thinset (grey) No 42, 43, 44
Proposed VA Hospital Garland – Three Buildings
2300 Marie Curie Boulevard
Responsive ■ Resourceful ■ Reliable 12
Containing
Sample
Numbers
8" X 8" Ceramic Floor Tile (grey)/Grout (dark grey) & Thinset (grey) No 45, 46, 47
Interior Building Caulk (white) associated w/Plumbing No 48,49, 50
Carpet Mastic (yellow) No 51, 52, 53 Fiberglass Reinforced Panel Mastic (clear) No 54, 55, 56
Stair Tread (tan, w/white flakes) Mastic (yellow) No 57, 58, 59 2' X 2' Ceiling Tile (white, pinhole & fissure) No 60, 61, 62
2' X 2' Ceiling Tile (pinhole & pockmark) No 63, 64, 65 Resilient Sheet Flooring (blonde/red, faux wood) No 66, 67, 68 Resilient Sheet Flooring (blue/grey, faux stone) No 69, 70, 71
4" X 4" Ceramic Wall Tile (white)/Grout No 72, 73, 74 2" X 2" Ceramic Floor Tile (grey)/Grout (dark gray) &
Thinset No 75, 76, 77
Fire Stop (red) No 78, 79, 80 Interior Building Caulk (light grey) associated w/Casework No 81, 82, 83
Building A – 4th & 5th Floors
2' X 2' Ceiling Tile (white, pinhole & pockmark) No 1, 2, 3 Finished Drywall Wall System (beige, semi-smooth) Yes 4, 5, 6, 7, 8, 9, 10
4" Cove Base & Mastic (cream) No 11, 12, 13 12" X 12" Vinyl Floor Tile (grey/purple, mottled) &
Mastic No 14, 15, 16
Finished Drywall Ceiling System (white, smooth) No 17, 18, 19, 20, 21, 22, 23
Fiberglass Reinforced Panel Mastic (cream) No 24, 25, 26 Resilient Sheet Flooring (white/purple, speckled) No 27, 28, 29
Interior Window Caulk (grey) No 30, 31, 32 2' X 2' Ceiling Tile (white, smooth) No 33, 34, 35
Interior Building Caulk (white) associated w/Casework No 36, 37, 38
4" X 4" Ceramic Wall Tile (multi-color)/Grout (grey) & Thinset (white) No 39, 40, 41
Proposed VA Hospital Garland – Three Buildings
2300 Marie Curie Boulevard
Responsive ■ Resourceful ■ Reliable 13
Containing
Sample
Numbers
8" X 8" Ceramic Floor Tile (grey, speckled)/Grout (grey) & Thinset (grey) No 42, 43, 44
Interior Building Caulk (white) associated w/Plumbing No 45, 46, 47
Sink Undercoat (white) No 48, 49, 50 Sink Undercoat (grey) No 51, 52, 53 Carpet Mastic (yellow) No 54, 55, 56
6" X 36" Vinyl Floor Tile (brown/grey, faux wood plank) & Mastic (yellow) No 57, 58, 59
Carpet Mastic (yellow/green) No 60, 61, 62 Thermal Pipe Insulation (yellow)/Wrap (white) &
Mastic (white) No 63, 64, 65
12" X 12" Vinyl Floor Tile (pink, mottled) & Mastic (yellow) No 66, 67, 68
Wall Covering (cream, woven) on Drywall No 69, 70, 71 12" X 12" Vinyl Floor Tile (grey, mottled) & Mastic
(yellow) No 72, 73, 74
Sink Undercoat (black) No 75, 76, 77 Resilient Sheet Flooring (grey, diamond plate) No 78, 79, 80
Epoxy Floor Coating (grey, rough) No 81, 82, 83 Interior Textured Concrete (white, smooth) No 84, 85, 86
Duct Mastic (black) on Foil Wrap & Insulation (pink) No 87, 88, 89 Thermal Pipe Insulation (yellow)/Wrap (tan), Old
Style No 90, 91, 92
Unfinished Drywall (green) & Joint Compound No 93, 94, 95 12" X 12" Vinyl Floor Tile (blue, mottled) & Mastic
(yellow) No 96, 97, 98
Firestop (red) No 99, 100, 101 Building A – Stairwells
Finished Drywall Wall System (beige, semi-smooth) No S-1, 2, 3, 4, 5, 6, Stair Tread (tan, diamond pattern) & Mastic (yellow) No S-8, 9, 10 Firestop (red) No S-11, 12, 13
Proposed VA Hospital Garland – Three Buildings
2300 Marie Curie Boulevard
Responsive ■ Resourceful ■ Reliable 14
Containing
Sample
Numbers
Interior Concrete Texture (cream, semi-smooth) Yes S-14, 15, 16, 17, Interior Concrete Texture (cream, semi-smooth) No S-18, 19, 20
Textured CMU Block (cream) Yes S-21, 22, 23, 24, 25, 26, 27
Stair Tread Grey (circle pattern) & Mastic (cream) No S-28, 29, 30
Fire Proofing (grey, tan) Yes S-31, 32, 33, 34, Epoxy Floor Coating (grey) No S-36, 37, 38 4" Cove Base Mastic (yellow/brown) No S-39, 40, 41
Interior Building Caulk (yellow) No S-42, 43, 44 Plaza Building – 700 Walter Reed Boulevard
Plaza 1 – Exterior & Roof
EPDM Roofing Membrane (black) No 1, 2, 3 Exterior Texture on Concrete (white, rough) No 4, 5, 6, 7, 8
Ext…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .