04_46-60_851PC2048_HNC_BD_Plans.pdf
PDF 11 MB Posted
- Solicitation number
- 36C10F20R0055
About this file
This federal solicitation seeks proposals for the Phase 5 expansion of the Houston National Cemetery in Houston, Texas. The project includes developing approximately 50 acres of land to construct additional gravesites, roads, parking, utilities and other site improvements. Specifically, the project requires the development of approximately 14,000 pre-placed crypt full casket gravesites, 350 oversize pre-placed crypt casket gravesites, 2,000 traditional in-ground cremains sites, and 8,000 columbarium niches. Additional requirements include a 300-gravesite Hybrid Natural Memorial Wall and Ossuary, new entrance gate, updated irrigation system with new well and pond, and an improved drainage system. Proposals are due by August 10, 2020. The solicitation is set aside for Service-Disabled Veteran Owned Small Businesses with an estimated construction cost between $20-50 million. The soliciting agency is the Department of Veterans Affairs Office of Construction and Facilities Management.
View the file
Other files
Show all 35
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SECTION 12
2,856 DOUBLE-DEPTH
PRE-PLACED CRYPTS
(3'X8' PLOTS)
SECTION 10
350 OVERSIZED
DOUBLE-DEPTH
PRE-PLACED CRYPTS
(4'X10' PLOTS)
ME
MO
RI
AL
D
RI
VE
EX
TE
NS
IO
N
NEW ROAD 'A'
NEW
TRAFFIC CIRCLE
+0
+0
+5
8+00 9+00
10+00 11+00 12+00
0+00
1+
2+00
3+00
4+
5+
6+0026+28
4:1 MAX
4:1 MAX
4:1 MAX
4:1
MAX
4:1 M
AX
8' WIDE EMBANKMENT
TOP OF EMBANKMENT
ELEV.=91.5
POND B
BOTTOM ELEV=82.00
NORMAL WSE=86.79
100-YR WSE=90.84
TOP ELEV=91.50
NORMAL
WSE=86.79
@10:1 SLOPE
4:1 4:1
4" PERF.
HDPE
UNDRN
(TYP.)
4" PERF.
HDPE UNDRN
(TYP.)
4" PERF.
HDPE UNDRN
(TYP.)
8'
4" PERF.
HDPE UNDRN
(TYP.)
8' WIDE EMBANKMENT
TOP OF EMBANKMENT
ELEV.=91.5
POND C
BOTTOM ELEV=82.00
NORMAL WSE=86.79
100-YR WSE=90.71
TOP ELEV=91.50
CONTRACTOR TO LOCATE THE EXISTING 24"
PIPE AND PLACE NEW 36" DUAL EQUALIZATION
PIPES PARALLEL TO THE EXISTING PIPE AND
MAINTAIN 10' OF CLEARANCE FROM THE EX. PIPE
TO THE PR. PIPE. NEW 36" PIPES TO EXTEND TO
THE SAME LENGTH AS THE EX. 24" PIPE.
8'
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
HARRIS COUNTY, TEXAS
851PC2048
FEBRUARY 7, 2020 BJS ACS
GordonPROGRAMMING AND PLANNING
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
SURVEY AND MAPPING
SECURITY CONSULTING
Dwg. of 215
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
BID DOCUMENTS SUBMISSION
BID DOCUMENTS
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
148 S. Queen Street, Suite 201
Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
HOUSTON NATIONAL CEMETERY
PHASE 5 DEVELOPMENTThe LA Group
(518) 587-8100 Aqua Engineering, Inc.
(970) 372-6104
OCMI
(202) 607-7575 rvi
(512) 480-0032 AES Group
(303) 841-3922 Gilpin Engineering
(512) 220-8100 Komatsu Inc.
(817) 587-8100
ECS Southwest, LLP 713-955-1980
GIS, Inc.
(205) 941-0442
GRADING AND DRAINAGE PLAN
AREA 8
CG108
KEY MAP
(NOT TO SCALE)
1 2
7 8A
9A
9B
8B
9C
REINFORCED GRASSED
SPILLWAY ARMORING
GRAPHIC LEGEND:
LIMITS OF WORK
PRE-PLACED CRYPTS
PERIMETER CRYPT
INTERIOR CRYPT
NEW STORM SEWER
CRYPT UNDER DRAIN
PROPOSED GROUND
ELEVATION*
MATCH EXISTING
GROUND ELEVATION*
PROPOSED TOP
OF CURB ELEVATION
MATCH EXISTING TOP
OF CURB ELEVATION
NEW STORM STRUCTURE
DRAINAGE FLOW ARROW
*WHEN SHOWN LABELING CURB AND GUTTER, THIS
ELEVATION DENOTES THE FLOW LINE ELEVATION.
GRADING NOTES:
1. ALL GRAVESITE GRID MONUMENTS SHOWN SHALL BE LAID OUT BY A
LICENSED LAND SURVEYOR ENGAGED BY THE CONTRACTOR, USING
COORDINATES & BEARINGS SHOWN.
2. COORDINATE INFORMATION SHOWN IS BASED ON THE HORIZONTAL
DATUM TEXAS STATE PLANE SOUTH CENTRAL ZONE NAD83 AND
VERTICAL DATUM NAVD88.
3. CONTRACTOR SHALL PERFORM UTILITY LOCATION FOR ALL
UNDERGROUND UTILITIES AND NOTIFY THE VA IN THE EVENT
ADJUSTMENTS ARE REQUIRED TO ENSURE THE IMPROVEMENTS ARE
CONSTRUCTED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS
PRIOR TO COMMENCING CONSTRUCTION ACTIVITIES.
AREA 8B
AREA 8A
GRADING KEY NOTE LEGEND:
KEY NO. DESCRIPTION DETAIL/PG
CONTRACTOR TO PROVIDE
30' TRANSITION CURVE AROUND RIDGE LINE
AutoCAD SHX Text M11B
AutoCAD SHX Text
BM11
AutoCAD SHX Text M11A
AutoCAD SHX Text M10A
AutoCAD SHX Text
BM10
AutoCAD SHX Text M10B
AutoCAD SHX Text APPROXIMATE LOCATION OF 24" SD PIPE. @82.00 (0% SLOPE) (PIPE UNDER WATER, SHOWN PER VA PROJECT #851CM2043 RECORD DRAWINGS)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 91.5
AutoCAD SHX Text
AutoCAD SHX Text 91.5
AutoCAD SHX Text
AutoCAD SHX Text
IRRIGATION/DETENTION POND 'C' HC PROJECT# 2008130
AutoCAD SHX Text APPROXIMATE LOCATION OF 24" SD PIPE. @82.00 (0% SLOPE) (PIPE UNDER WATER, SHOWN PER VA PROJECT #851CM2043 RECORD DRAWINGS)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 91.5
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 91.5
AutoCAD SHX Text
AutoCAD SHX Text 91.5
AutoCAD SHX Text 91.5
AutoCAD SHX Text
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text
EM
AutoCAD SHX Text
MATCHLINE SEE SHEET CG107CG107
AutoCAD SHX Text
MATCHLINE SEE SHEET CG105CG105
AutoCAD SHX Text
AutoCAD SHX Text 5±
AutoCAD SHX Text
GS-ME
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
GS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
TC
AutoCAD SHX Text
AutoCAD SHX Text 0±
AutoCAD SHX Text
TC-ME
AutoCAD SHX Text
GRAPHICAL SCALE: 1" = 30'
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
MATCHLINE SEE SHEET THIS SHEET
AutoCAD SHX Text
MATCHLINE SEE SHEET CG109CG109
AutoCAD SHX Text
MATCHLINE SEE SHEET THIS SHEET
AutoCAD SHX Text
AutoCAD SHX Text
DT503
SECTION GB
300 HYBRID NATURAL
(GREEN) BURIAL SECTION
(5'X10' PLOTS)
2% MIN.
2% MIN.
REPAIR EXISTING TRASH
RACK (SEE SPECS)
POND C
BOTTOM ELEV=82.00
NORMAL WSE=86.79
100-YR WSE=90.71
TOP ELEV=91.50
CONTRACTOR SHALL NOT DO ANY
WORK SOUTH OF EXISTING
CEMETERY FENCE.
0+
1+
1+87
CONTRACTOR SHALL NOT DO ANY
WORK SOUTH OF EXISTING
CEMETERY FENCE.
EXPANSION
JOINT (TYP.)
CONTROL
JOINT (TYP.)
REMOVE EXISTING STORM SEWER
AND REPLACE WITH CLASS III RCP
STORM SEWER. CONTRACTOR TO
REGRADE TO MATCH EXISTING
ELEVATIONS.
CONTRACTOR TO MATCH EXISTING
INVERT ELEVATION.
CONTRACTOR TO MATCH EXISTING
INVERT ELEVATIONS.
CONTRACTOR TO MATCH EXISTING
INVERT ELEVATIONS.
REMOVE EXISTING STORM SEWER
AND REPLACE WITH CLASS III RCP
STORM SEWER. CONTRACTOR TO
REGRADE TO MATCH EXISTING
ELEVATIONS.
GRADING AND DRAINAGE PLAN
AREA 9
CG109
KEY MAP
(NOT TO SCALE)
1 2
7 8A
9A
9B
8B
9C
REINFORCED GRASSED
SPILLWAY ARMORING
GRAPHIC LEGEND:
LIMITS OF WORK
PRE-PLACED CRYPTS
PERIMETER CRYPT
INTERIOR CRYPT
NEW STORM SEWER
CRYPT UNDER DRAIN
PROPOSED GROUND
ELEVATION*
MATCH EXISTING
GROUND ELEVATION*
PROPOSED TOP
OF CURB ELEVATION
MATCH EXISTING TOP
OF CURB ELEVATION
NEW STORM STRUCTURE
DRAINAGE FLOW ARROW
*WHEN SHOWN LABELING CURB AND GUTTER, THIS
ELEVATION DENOTES THE FLOW LINE ELEVATION.
GRADING NOTES:
1. ALL GRAVESITE GRID MONUMENTS SHOWN SHALL BE LAID OUT BY A
LICENSED LAND SURVEYOR ENGAGED BY THE CONTRACTOR, USING
COORDINATES & BEARINGS SHOWN.
2. COORDINATE INFORMATION SHOWN IS BASED ON THE HORIZONTAL
DATUM TEXAS STATE PLANE SOUTH CENTRAL ZONE NAD83 AND
VERTICAL DATUM NAVD88.
3. CONTRACTOR SHALL PERFORM UTILITY LOCATION FOR ALL
UNDERGROUND UTILITIES AND NOTIFY THE VA IN THE EVENT
ADJUSTMENTS ARE REQUIRED TO ENSURE THE IMPROVEMENTS ARE
CONSTRUCTED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS
PRIOR TO COMMENCING CONSTRUCTION ACTIVITIES.
AREA 9A AREA 9B
AREA 9C
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
HARRIS COUNTY, TEXAS
851PC2048
FEBRUARY 7, 2020 BJS ACS
GordonPROGRAMMING AND PLANNING
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
SURVEY AND MAPPING
SECURITY CONSULTING
Dwg. of 215
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
BID DOCUMENTS SUBMISSION
BID DOCUMENTS
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
148 S. Queen Street, Suite 201
Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
HOUSTON NATIONAL CEMETERY
PHASE 5 DEVELOPMENTThe LA Group
(518) 587-8100 Aqua Engineering, Inc.
(970) 372-6104
OCMI
(202) 607-7575 rvi
(512) 480-0032 AES Group
(303) 841-3922 Gilpin Engineering
(512) 220-8100 Komatsu Inc.
(817) 587-8100
ECS Southwest, LLP 713-955-1980
GIS, Inc.
(205) 941-0442
AutoCAD SHX Text SD MANHOLE TOP RIM ELEV: 89.75' INV. IN ELEV (N): 86.17' INV. OUT ELEV (S): 86.10'
AutoCAD SHX Text
SD SAFETY END TREATMENT 18" HDPE PIPE FL ELEV: 86.79'
AutoCAD SHX Text
IRRIGATION/DETENTION POND 'C' HC PROJECT# 2008130
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
HCFCD UNIT NO. P118-31-00
AutoCAD SHX Text APPROXIMATE LOCATION OF IRREGULAR EXISTING HCFCD DRAINAGE EASEMENT W/D H.C.C.F. NO. R882145
AutoCAD SHX Text
EXISTING STORM SEWER OUTFALL HC PROJECT# 2008130
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text APROXIMATE LOCATION OF IRREGULAR EXISTING HCFCD DRAINAGE EASEMENT W/D H.C.C.F. NO. R882145
AutoCAD SHX Text
HCFCD UNIT NO. P118-31-00
AutoCAD SHX Text
SD MANHOLE/CURB INLET TOP RIM ELEV: 97.22' FLOODED
AutoCAD SHX Text
SD 24" HDPE FL ELEV: 90.49'
AutoCAD SHX Text
SD MANHOLE/CURB INLET TOP RIM ELEV: 96.59' FLOODED
AutoCAD SHX Text
SD MANHOLE/CURB INLET TOP RIM ELEV: 96.49' FLOODED
AutoCAD SHX Text
SD MANHOLE TOP RIM ELEV: 97.08' FLOODED
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text S1
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text
EM
AutoCAD SHX Text
AutoCAD SHX Text 5±
AutoCAD SHX Text
GS-ME
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
GS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
TC
AutoCAD SHX Text
AutoCAD SHX Text 0±
AutoCAD SHX Text
TC-ME
AutoCAD SHX Text
GRAPHICAL SCALE: 1" = 30'
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
MATCHLINE SEE SHEET CG108CG108
SECTION 19
1,000 IN-GROUND
CREMAINS SITES
(4'X4' PLOTS)
MEMORIAL DRIVE EXTENSION
SECTION 20
1,000 IN-GROUND
CREMAINS SITES
(4'X4' PLOTS)
MEMORIAL DRIVE EXTENSION
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
HARRIS COUNTY, TEXAS
851PC2048
FEBRUARY 7, 2020 BJS ACS
GordonPROGRAMMING AND PLANNING
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
SURVEY AND MAPPING
SECURITY CONSULTING
Dwg. of 215
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
BID DOCUMENTS SUBMISSION
BID DOCUMENTS
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
148 S. Queen Street, Suite 201
Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
HOUSTON NATIONAL CEMETERY
PHASE 5 DEVELOPMENTThe LA Group
(518) 587-8100 Aqua Engineering, Inc.
(970) 372-6104
OCMI
(202) 607-7575 rvi
(512) 480-0032 AES Group
(303) 841-3922 Gilpin Engineering
(512) 220-8100 Komatsu Inc.
(817) 587-8100
ECS Southwest, LLP 713-955-1980
GIS, Inc.
(205) 941-0442
BURIAL SECTION GRADING
ENLARGMENT SECTION 19 AND 20
CG110
LEGEND:
GRADING NOTES:
AutoCAD SHX Text
SM19A
AutoCAD SHX Text
SM19B
AutoCAD SHX Text
FINISHED GRADE PITCH: 2.1% N31° 21' 40.6"E
AutoCAD SHX Text
SM20B
AutoCAD SHX Text
FWS-5
AutoCAD SHX Text
SM20A
AutoCAD SHX Text
FINISHED GRADE PITCH: 2.0% N28° 31' 47.3"E
AutoCAD SHX Text
GRAPHICAL SCALE: 1" = 10'
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
IN-GROUND CREMAINS PLOTS
AutoCAD SHX Text
GRAVESITE GRID MONUMENT
AutoCAD SHX Text
PRE-PLACED CRYPTS
AutoCAD SHX Text
SECTION MARKER
AutoCAD SHX Text
PERIMETER CRYPT (TYP.)
AutoCAD SHX Text
INTERIOR CRYPT (TYP.)
AutoCAD SHX Text
LIMITS OF WORK
AutoCAD SHX Text
ELEVATION LABEL
AutoCAD SHX Text
FINISHED GRADE ELEVATION
AutoCAD SHX Text
FG
AutoCAD SHX Text
TOP OF CRYPT LID ELEVATION
AutoCAD SHX Text
TL
AutoCAD SHX Text
EXISTING CONTOUR (5' INTERVAL)
AutoCAD SHX Text
EXISTING CONTOUR (1' INTERVAL)
AutoCAD SHX Text
PROPOSED CONTOUR (5' INTERVAL)
AutoCAD SHX Text
PROPOSED CONTOUR (1' INTERVAL)
AutoCAD SHX Text
1. CONTRACTOR TO PROVIDE AMENDED SOILS ABOVE CRYPTS. 2. CONTRACTOR SHALL PROVIDE, AS A SUBMITTAL, A PROPOSED PLAN FOR CONSTRUCTING AND PERFORMING THE GRADING IN CRYPT FIELDS TO THE CEMETERY DIRECTOR FOR REVIEW AND APPROVAL. PLAN TO ADDRESS ANY POTENTIAL RAIN IMPACTS DURING EXCAVATION OF THE CRYPT FIELDS. 3. NO BACKFILL SHALL BE PLACED ON THE CRYPTS PRIOR TO BEING INSPECTED AND ACCEPTED BY THE RE THAT THE LID AND CRYPT NUMBERS MATCH.
AutoCAD SHX Text
FG 100.00 TL 98.25
AutoCAD SHX Text
LIMITS OF GRADING
AutoCAD SHX Text
UNDERDRAIN INVERT
AutoCAD SHX Text
INV
AutoCAD SHX Text
CLEANOUT INVERT OUT AND FINISHED GRADE ELEVATION LABEL
FG 100.00 INV=91.75
SECTION 14
2,832 DOUBLE-DEPTH
PRE-PLACED CRYPTS
(3'X8' PLOTS)
84.50'-4" HDPE PERFORATED
PIPE @ 0.80%
72.07'-4" HDPE PERFORATED
PIPE @1.60%
MEMORIAL DRIVE
EXTENSION
.25
° B
EN
D
.5°
B
EN
D
178.00'-HDPE PERFORATED
PIPE @ 1.22%
95.60'-4" HDPE PERFORATED
PIPE @ 0.80%
95.60'-4" HDPE PERFORATED
PIPE @ 0.80%
96.50'-4" HDPE PERFORATED
PIPE @ 0.80%
30° BEND
11.25° BEND
11.25° BEND
45° BEND
45° BEND
45° BEND
45° BEND 45° BEND
45° BEND
45° BEND
45° BEND
45° BEND
45° BEND
45° BEND
45° BEND
45° BEND
45° BEND
SECTION 14
2,832 DOUBLE-DEPTH
PRE-PLACED CRYPTS
(3'X8' PLOTS)
96.50'-4" HDPE PERFORATED
PIPE @ 0.80%
95.60'-4" HDPE PERFORATED
PIPE @ 0.80%
96.44'-4" HDPE PERFORATED
PIPE @ 0.80%
83.70'-4" HDPE PERFORATED
PIPE @ 0.80%
45° BEND
30° BEND
30° BEND
15.33'-4" HDPE PIPE
45° BEND
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
HARRIS COUNTY, TEXAS
851PC2048
FEBRUARY 7, 2020 BJS ACS
GordonPROGRAMMING AND PLANNING
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
SURVEY AND MAPPING
SECURITY CONSULTING
Dwg. of 215
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
BID DOCUMENTS SUBMISSION
BID DOCUMENTS
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
148 S. Queen Street, Suite 201
Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
HOUSTON NATIONAL CEMETERY
PHASE 5 DEVELOPMENTThe LA Group
(518) 587-8100 Aqua Engineering, Inc.
(970) 372-6104
OCMI
(202) 607-7575 rvi
(512) 480-0032 AES Group
(303) 841-3922 Gilpin Engineering
(512) 220-8100 Komatsu Inc.
(817) 587-8100
ECS Southwest, LLP 713-955-1980
GIS, Inc.
(205) 941-0442
BURIAL SECTION GRADING
ENLARGEMENT SECTION 14
CG111
LEGEND:
GRADING NOTES:
AutoCAD SHX Text
SM14A
AutoCAD SHX Text
FWS-4
AutoCAD SHX Text
SM14B
AutoCAD SHX Text
SM19A
AutoCAD SHX Text
FINISHED GRADE/ SUBGRADE PITCH: 2.1% S70° 14' 38.6"E
AutoCAD SHX Text
FINISHED GRADE/ SUBGRADE PITCH: 2.1% S64° 05' 19.1"W
AutoCAD SHX Text
GRAPHICAL SCALE: 1" = 10'
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
MATCHLINE SEE RIGHT
AutoCAD SHX Text
MATCHLINE SEE LEFT
AutoCAD SHX Text
GRAVESITE GRID MONUMENT
AutoCAD SHX Text
PRE-PLACED CRYPTS
AutoCAD SHX Text
SECTION MARKER
AutoCAD SHX Text
PERIMETER CRYPT (TYP.)
AutoCAD SHX Text
INTERIOR CRYPT (TYP.)
AutoCAD SHX Text
LIMITS OF WORK
AutoCAD SHX Text
ELEVATION LABEL
AutoCAD SHX Text
FINISHED GRADE ELEVATION
AutoCAD SHX Text
FG
AutoCAD SHX Text
TOP OF CRYPT LID ELEVATION
AutoCAD SHX Text
TL
AutoCAD SHX Text
EXISTING CONTOUR (5' INTERVAL)
AutoCAD SHX Text
EXISTING CONTOUR (1' INTERVAL)
AutoCAD SHX Text
PROPOSED CONTOUR (5' INTERVAL)
AutoCAD SHX Text
PROPOSED CONTOUR (1' INTERVAL)
AutoCAD SHX Text
1. CONTRACTOR TO PROVIDE AMENDED SOILS ABOVE CRYPTS. 2. CONTRACTOR SHALL PROVIDE, AS A SUBMITTAL, A PROPOSED PLAN FOR CONSTRUCTING AND PERFORMING THE GRADING IN CRYPT FIELDS TO THE CEMETERY DIRECTOR FOR REVIEW AND APPROVAL. PLAN TO ADDRESS ANY POTENTIAL RAIN IMPACTS DURING EXCAVATION OF THE CRYPT FIELDS. 3. NO BACKFILL SHALL BE PLACED ON THE CRYPTS PRIOR TO BEING INSPECTED AND ACCEPTED BY THE RE THAT THE LID AND CRYPT NUMBERS MATCH.
AutoCAD SHX Text
FG 100.00 TL 98.25
AutoCAD SHX Text
LIMITS OF GRADING
AutoCAD SHX Text
UNDERDRAIN INVERT
AutoCAD SHX Text
INV
AutoCAD SHX Text
CLEANOUT INVERT OUT AND FINISHED GRADE ELEVATION LABEL
SECTION 22
2,992 DOUBLE-DEPTH
PRE-PLACED CRYPTS
(3'X8' PLOTS)
8.7
8'- 4"
H
DP
E
PE
RF
OR
AT
ED
PI
PE
1.
ME
MO
RI
AL
D
RI
VE
EX
TE
NS
IO
N
.50
'-4 " H
DP
E
PE
RF
OR
AT
ED
PI
PE
1.
8.5
0'- 4"
H
DP
E
PE
RF
OR
AT
ED
PI
PE
1.
6.5
0'- 4"
H
DP
E
PE
RF
OR
AT
ED
PI
PE
1.
2.5
0'- 4"
H
DP
E
PE
RF
OR
AT
ED
PI
PE
1.
0.5
0'- 4"
H
DP
E
PE
RF
OR
AT
ED
PI
PE
1.
0.5
0'- 4"
H
DP
E
PE
RF
OR
AT
ED
PI
PE
1.
0.5
0'- 4"
H
DP
E
PE
RF
OR
AT
ED
PI
PE
1.
91.47'-4" HDPE PERFORATED
PIPE @
1.60%
45° BEND
45° BEND 45° BEND 45° BEND
45° BEND
22.5° BEND
11.25° BEND
11.25° BEND
11.25° BEND
20.24'-4"
HDPE PIPE
.07
'-4 " H
DP
E
PE
RF
OR
AT
ED
PI
PE
1.6 0%
22.5° BEND
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
HARRIS COUNTY, TEXAS
851PC2048
FEBRUARY 7, 2020 BJS ACS
GordonPROGRAMMING AND PLANNING
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
SURVEY AND MAPPING
SECURITY CONSULTING
Dwg. of 215
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
BID DOCUMENTS SUBMISSION
BID DOCUMENTS
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
148 S. Queen Street, Suite 201
Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
HOUSTON NATIONAL CEMETERY
PHASE 5 DEVELOPMENTThe LA Group
(518) 587-8100 Aqua Engineering, Inc.
(970) 372-6104
OCMI
(202) 607-7575 rvi
(512) 480-0032 AES Group
(303) 841-3922 Gilpin Engineering
(512) 220-8100 Komatsu Inc.
(817) 587-8100
ECS Southwest, LLP 713-955-1980
GIS, Inc.
(205) 941-0442
BURIAL SECTION GRADING
ENLARGEMENT SECTION 22
CG112
LEGEND:
GRADING NOTES:
AutoCAD SHX Text
SM22B
AutoCAD SHX Text
FINISHED GRADE/ SUBGRADE PITCH: 2.3% S41° 55' 20.3"W
AutoCAD SHX Text
FINISHED GRADE/ SUBGRADE PITCH: 2.3% S48° 04' 39.7"E
AutoCAD SHX Text
GRAPHICAL SCALE: 1" = 10'
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
MATCH LINE SEE BELOW
AutoCAD SHX Text
GRAVESITE GRID MONUMENT
AutoCAD SHX Text
PRE-PLACED CRYPTS
AutoCAD SHX Text
SECTION MARKER
AutoCAD SHX Text
PERIMETER CRYPT (TYP.)
AutoCAD SHX Text
INTERIOR CRYPT (TYP.)
AutoCAD SHX Text
LIMITS OF WORK
AutoCAD SHX Text
ELEVATION LABEL
AutoCAD SHX Text
FINISHED GRADE ELEVATION
AutoCAD SHX Text
FG
AutoCAD SHX Text
TOP OF CRYPT LID ELEVATION
AutoCAD SHX Text
TL
AutoCAD SHX Text
EXISTING CONTOUR (5' INTERVAL)
AutoCAD SHX Text
EXISTING CONTOUR (1' INTERVAL)
AutoCAD SHX Text
PROPOSED CONTOUR (5' INTERVAL)
AutoCAD SHX Text
PROPOSED CONTOUR (1' INTERVAL)
AutoCAD SHX Text
1. CONTRACTOR TO PROVIDE AMENDED SOILS ABOVE CRYPTS. 2. CONTRACTOR SHALL PROVIDE, AS A SUBMITTAL, A PROPOSED PLAN FOR CONSTRUCTING AND PERFORMING THE GRADING IN CRYPT FIELDS TO THE CEMETERY DIRECTOR FOR REVIEW AND APPROVAL. PLAN TO ADDRESS ANY POTENTIAL RAIN IMPACTS DURING EXCAVATION OF THE CRYPT FIELDS. 3. NO BACKFILL SHALL BE PLACED ON THE CRYPTS PRIOR TO BEING INSPECTED AND ACCEPTED BY THE RE THAT THE LID AND CRYPT NUMBERS MATCH.
AutoCAD SHX Text
FG 100.00 TL 98.25
AutoCAD SHX Text
LIMITS OF GRADING
AutoCAD SHX Text
UNDERDRAIN INVERT
AutoCAD SHX Text
INV
AutoCAD SHX Text
CLEANOUT INVERT OUT AND FINISHED GRADE ELEVATION LABEL
SECTION 13
2,944 DOUBLE-DEPTH
PRE-PLACED CRYPTS
(3'X8' PLOTS)
4.5
0'- 4"
H
DP
E
PE
RF
OR
AT
ED
P
IP
E
1.
ME
MO
RI
AL
D
RI
VE
EX
TE
NS
IO
N
.50
'-4 " H
DP
E
PE
RF
OR
AT
ED
P
IP
E
1.
.50
'-4 " H
DP
E
PE
RF
OR
AT
ED
P
IP
E
1.
4.5
0'- 4"
H
DP
E
PE
RF
OR
AT
ED
P
IP
E
1.
4.5
0'- 4"
H
DP
E
PE
RF
OR
AT
ED
P
IP
E
1.
.50 '-4
" H
DP
E
PE
RF
OR
AT
ED
P
IP
E
1.
9.6
6'- 4"
H
DP
E
PE
RF
OR
AT
ED
P
IP
E
1.
.97
'-4 " H
DP
E
PE
RF
OR
AT
ED
P
IP
E
1.
1.8
1'- 4"
H
DP
E
PE
RF
OR
AT
ED
PI
PE
1.
.81
'-4 " H
DP
E
PE
RF
OR
AT
ED
PI
PE
1.
45° BEND
45° BEND
45° BEND
45° BEND
45° BEND
45° BEND
45° BEND
45° BEND
44.87'-4" HDPE PIPE
4" HDPE PIPE 4" HDPE PIPE 4" HDPE PIPE 28.97'-4"
HDPE PIPE
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
HARRIS COUNTY, TEXAS
851PC2048
FEBRUARY 7, 2020 BJS ACS
GordonPROGRAMMING AND PLANNING
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
SURVEY AND MAPPING
SECURITY CONSULTING
Dwg. of 215
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
BID DOCUMENTS SUBMISSION
BID DOCUMENTS
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
148 S. Queen Street, Suite 201
Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
HOUSTON NATIONAL CEMETERY
PHASE 5 DEVELOPMENTThe LA Group
(518) 587-8100 Aqua Engineering, Inc.
(970) 372-6104
OCMI
(202) 607-7575 rvi
(512) 480-0032 AES Group
(303) 841-3922 Gilpin Engineering
(512) 220-8100 Komatsu Inc.
(817) 587-8100
ECS Southwest, LLP 713-955-1980
GIS, Inc.
(205) 941-0442
BURIAL SECTION GRADING
ENLARGEMENT SECTION 13
CG113
LEGEND:
GRADING NOTES:
AutoCAD SHX Text
SM13A
AutoCAD SHX Text
SM13B
AutoCAD SHX Text
FINISHED GRADE/ SUBGRADE PITCH: 2.1% N54° 20' 53.7"E
AutoCAD SHX Text
FINISHED GRADE/ SUBGRADE PITCH: 2.1% N60° 31' 14.9"W
AutoCAD SHX Text
GRAPHICAL SCALE: 1" = 10'
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
GRAVESITE GRID MONUMENT
AutoCAD SHX Text
PRE-PLACED CRYPTS
AutoCAD SHX Text
SECTION MARKER
AutoCAD SHX Text
PERIMETER CRYPT (TYP.)
AutoCAD SHX Text
INTERIOR CRYPT (TYP.)
AutoCAD SHX Text
LIMITS OF WORK
AutoCAD SHX Text
ELEVATION LABEL
AutoCAD SHX Text
FINISHED GRADE ELEVATION
AutoCAD SHX Text
FG
AutoCAD SHX Text
TOP OF CRYPT LID ELEVATION
AutoCAD SHX Text
TL
AutoCAD SHX Text
EXISTING CONTOUR (5' INTERVAL)
AutoCAD SHX Text
EXISTING CONTOUR (1' INTERVAL)
AutoCAD SHX Text
PROPOSED CONTOUR (5' INTERVAL)
AutoCAD SHX Text
PROPOSED CONTOUR (1' INTERVAL)
AutoCAD SHX Text
1. CONTRACTOR TO PROVIDE AMENDED SOILS ABOVE CRYPTS. 2. CONTRACTOR SHALL PROVIDE, AS A SUBMITTAL, A PROPOSED PLAN FOR CONSTRUCTING AND PERFORMING THE GRADING IN CRYPT FIELDS TO THE CEMETERY DIRECTOR FOR REVIEW AND APPROVAL. PLAN TO ADDRESS ANY POTENTIAL RAIN IMPACTS DURING EXCAVATION OF THE CRYPT FIELDS. 3. NO BACKFILL SHALL BE PLACED ON THE CRYPTS PRIOR TO BEING INSPECTED AND ACCEPTED BY THE RE THAT THE LID AND CRYPT NUMBERS MATCH.
AutoCAD SHX Text
FG 100.00 TL 98.25
AutoCAD SHX Text
LIMITS OF GRADING
AutoCAD SHX Text
UNDERDRAIN INVERT
AutoCAD SHX Text
INV
AutoCAD SHX Text
CLEANOUT INVERT OUT AND FINISHED GRADE ELEVATION LABEL
(WITHIN 3'X8' PLOTS)
ME
MO
RI
AL
D
RI
VE
EX
TE
NS
IO
N
SECTION 23
2,376 DOUBLE-DEPTH
PRE-PLACED CRYPTS
(3'X8' PLOTS)
.50
'-4 " H
DP
E
PE
RF
OR
AT
ED
P
IP
E
0.
.50
'-4 " H
DP
E
PE
RF
OR
AT
ED
P
IP
E
0.
.50
'-4 " H
DP
E
PE
RF
OR
AT
ED
P
IP
E
0.
2.5
0'- 4"
H
DP
E
PE
RF
OR
AT
ED
P
IP
E
0.
2.5
0'- 4"
H
DP
E
PE
RF
OR
AT
ED
P
IP
E
0.
.50 '-4
" H
DP
E
PE
RF
OR
AT
ED
P
IP
E
0.
3.0
0'- 4"
H
DP
E
PE
RF
OR
AT
ED
P
IP
E
0.
45° BEND 45° BEND 45° BEND 45° BEND
45° BEND
45° BEND 45° BEND 45° BEND
35.24'-4" HDPE PIPE
23.24'-4" HDPE PIPE
23.24'-4" HDPE PIPE
29.24'-4" HDPE PIPE
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
HARRIS COUNTY, TEXAS
851PC2048
FEBRUARY 7, 2020 BJS ACS
GordonPROGRAMMING AND PLANNING
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
SURVEY AND MAPPING
SECURITY CONSULTING
Dwg. of 215
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
BID DOCUMENTS SUBMISSION
BID DOCUMENTS
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
148 S. Queen Street, Suite 201
Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
HOUSTON NATIONAL CEMETERY
PHASE 5 DEVELOPMENTThe LA Group
(518) 587-8100 Aqua Engineering, Inc.
(970) 372-6104
OCMI
(202) 607-7575 rvi
(512) 480-0032 AES Group
(303) 841-3922 Gilpin Engineering
(512) 220-8100 Komatsu Inc.
(817) 587-8100
ECS Southwest, LLP 713-955-1980
GIS, Inc.
(205) 941-0442
BURIAL SECTION GRADING
ENLARGEMENT SECTION 23
CG114
LEGEND:
GRADING NOTES:
AutoCAD SHX Text
SM23B
AutoCAD SHX Text
SM23A
AutoCAD SHX Text
FINISHED GRADE/ SUBGRADE PITCH: 2.0% N65° 08' 56.7"E
AutoCAD SHX Text
FINISHED GRADE/ SUBGRADE PITCH: 2.0% N58° 59' 37.3"E
AutoCAD SHX Text
GRAPHICAL SCALE: 1" = 10'
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
GRAVESITE GRID MONUMENT
AutoCAD SHX Text
PRE-PLACED CRYPTS
AutoCAD SHX Text
SECTION MARKER
AutoCAD SHX Text
PERIMETER CRYPT (TYP.)
AutoCAD SHX Text
INTERIOR CRYPT (TYP.)
AutoCAD SHX Text
LIMITS OF WORK
AutoCAD SHX Text
ELEVATION LABEL
AutoCAD SHX Text
FINISHED GRADE ELEVATION
AutoCAD SHX Text
FG
AutoCAD SHX Text
TOP OF CRYPT LID ELEVATION
AutoCAD SHX Text
TL
AutoCAD SHX Text
EXISTING CONTOUR (5' INTERVAL)
AutoCAD SHX Text
EXISTING CONTOUR (1' INTERVAL)
AutoCAD SHX Text
PROPOSED CONTOUR (5' INTERVAL)
AutoCAD SHX Text
PROPOSED CONTOUR (1' INTERVAL)
AutoCAD SHX Text
1. CONTRACTOR TO PROVIDE AMENDED SOILS ABOVE CRYPTS. 2. CONTRACTOR SHALL PROVIDE, AS A SUBMITTAL, A PROPOSED PLAN FOR CONSTRUCTING AND PERFORMING THE GRADING IN CRYPT FIELDS TO THE CEMETERY DIRECTOR FOR REVIEW AND APPROVAL. PLAN TO ADDRESS ANY POTENTIAL RAIN IMPACTS DURING EXCAVATION OF THE CRYPT FIELDS. 3. NO BACKFILL SHALL BE PLACED ON THE CRYPTS PRIOR TO BEING INSPECTED AND ACCEPTED BY THE RE THAT THE LID AND CRYPT NUMBERS MATCH.
AutoCAD SHX Text
FG 100.00 TL 98.25
AutoCAD SHX Text
LIMITS OF GRADING
AutoCAD SHX Text
UNDERDRAIN INVERT
AutoCAD SHX Text
INV
AutoCAD SHX Text
CLEANOUT INVERT OUT AND FINISHED GRADE ELEVATION LABEL
ME
MO
RI
AL
D
RI
VE
SECTION 12
2,856 DOUBLE-DEPTH
PRE-PLACED CRYPTS
(3'X8' PLOTS)
.46
'-4 " H
DP
E
PE
RF
OR
AT
ED
P
IP
E
0.
2.5
0'- 4"
H
DP
E
PE
RF
OR
AT
ED
P
IP
E
1.
ME
MO
RI
AL
D
RI
VE
EX
TE
NS
IO
N
.50
'-4 " H
DP
E
PE
RF
OR
AT
ED
P
IP
E
1.
2.5
0'- 4"
H
DP
E
PE
RF
OR
AT
ED
P
IP
E
1.
.50 '-4
" H
DP
E
PE
RF
OR
AT
ED
P
IP
E
1.
2.5
0'- 4"
H
DP
E
PE
RF
OR
AT
ED
P
IP
E
1.
.50 '-4
" H
DP
E
PE
RF
OR
AT
ED
P
IP
E
1.
.32
'-4 " H
DP
E
PE
RF
OR
AT
ED
P
IP
E
0.
202.53-4" HDPE PERFORATED
PIPE @ 1.21%
22.5° BEND
45° BEND
1-4"X4" TEE
1-45° BEND
WYE CONN.
22.5° BEND
1-4"X4" TEE
1-45° BEND
1-4"X4" TEE
1-45° BEND
1-4"X4" TEE
1-45° BEND
11.25° BEND
11.25° BEND
WYE CONN. WYE CONN. 45° BEND
45° BEND
45° BEND
45° BEND
45° BEND
56.00-4" HDPE PERFORATED
PIPE @ 2.61% 72.00-4" HDPE PERFORATED
PIPE @ 1.94%
96.00-4" HDPE PERFORATED
PIPE @ 1.94%
72.00-4" HDPE PERFORATED
PIPE @ 1.94%
24.00-4" HDPE PERFORATED
PIPE @ 1.94%
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
HARRIS COUNTY, TEXAS
851PC2048
FEBRUARY 7, 2020 BJS ACS
GordonPROGRAMMING AND PLANNING
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
SURVEY AND MAPPING
SECURITY CONSULTING
Dwg. of 215
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
BID DOCUMENTS SUBMISSION
BID DOCUMENTS
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
148 S. Queen Street, Suite 201
Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
HOUSTON NATIONAL CEMETERY
PHASE 5 DEVELOPMENTThe LA Group
(518) 587-8100 Aqua Engineering, Inc.
(970) 372-6104
OCMI
(202) 607-7575 rvi
(512) 480-0032 AES Group
(303) 841-3922 Gilpin Engineering
(512) 220-8100 Komatsu Inc.
(817) 587-8100
ECS Southwest, LLP 713-955-1980
GIS, Inc.
(205) 941-0442
BURIAL SECTION GRADING
ENLARGEMENT SECTION 12
CG115
LEGEND:
GRADING NOTES:
AutoCAD SHX Text
SM12A
AutoCAD SHX Text
FWS-2
AutoCAD SHX Text
FINISHED GRADE/ SUBGRADE PITCH: 2.2% S63° 39' 00.9"E
AutoCAD SHX Text
FINISHED GRADE/ SUBGRADE PITCH: 2.2% S57° 29' 41.4"W
AutoCAD SHX Text
GRAPHICAL SCALE: 1" = 10'
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
GRAVESITE GRID MONUMENT
AutoCAD SHX Text
PRE-PLACED CRYPTS
AutoCAD SHX Text
SECTION MARKER
AutoCAD SHX Text
PERIMETER CRYPT (TYP.)
AutoCAD SHX Text
INTERIOR CRYPT (TYP.)
AutoCAD SHX Text
LIMITS OF WORK
AutoCAD SHX Text
ELEVATION LABEL
AutoCAD SHX Text
FINISHED GRADE ELEVATION
AutoCAD SHX Text
FG
AutoCAD SHX Text
TOP OF CRYPT LID ELEVATION
AutoCAD SHX Text
TL
AutoCAD SHX Text
EXISTING CONTOUR (5' INTERVAL)
AutoCAD SHX Text
EXISTING CONTOUR (1' INTERVAL)
AutoCAD SHX Text
PROPOSED CONTOUR (5' INTERVAL)
AutoCAD SHX Text
PROPOSED CONTOUR (1' INTERVAL)
AutoCAD SHX Text
1. CONTRACTOR TO PROVIDE AMENDED SOILS ABOVE CRYPTS. 2. CONTRACTOR SHALL PROVIDE, AS A SUBMITTAL, A PROPOSED PLAN FOR CONSTRUCTING AND PERFORMING THE GRADING IN CRYPT FIELDS TO THE CEMETERY DIRECTOR FOR REVIEW AND APPROVAL. PLAN TO ADDRESS ANY POTENTIAL RAIN IMPACTS DURING EXCAVATION OF THE CRYPT FIELDS. 3. NO BACKFILL SHALL BE PLACED ON THE CRYPTS PRIOR TO BEING INSPECTED AND ACCEPTED BY THE RE THAT THE LID AND CRYPT NUMBERS MATCH.
AutoCAD SHX Text
FG 100.00 TL 98.25
AutoCAD SHX Text
LIMITS OF GRADING
AutoCAD SHX Text
UNDERDRAIN INVERT
AutoCAD SHX Text
INV
AutoCAD SHX Text
CLEANOUT INVERT OUT AND FINISHED GRADE ELEVATION LABEL
SECTION 10
350 OVERSIZED
PRE-PLACED CRYPTS
(4'X10' PLOTS)
90.00'-HDPE PERFORATED
PIPE @ 1.00%
NEW ROAD 'A'
1-4"x4" TEE
1-45° BEND
WYE CONN.
122.00'-HDPE PERFORATED
PIPE @ 1.75%
SECTION GB
300 GREEN
BURIAL SECTIONS
(5'X10' PLOTS)
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
HARRIS COUNTY, TEXAS
851PC2048
FEBRUARY 7, 2020 BJS ACS
GordonPROGRAMMING AND PLANNING
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
SURVEY AND MAPPING
SECURITY CONSULTING
Dwg. of 215
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
BID DOCUMENTS SUBMISSION
BID DOCUMENTS
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
148 S. Queen Street, Suite 201
Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
HOUSTON NATIONAL CEMETERY
PHASE 5 DEVELOPMENTThe LA Group
(518) 587-8100 Aqua Engineering, Inc.
(970) 372-6104
OCMI
(202) 607-7575 rvi
(512) 480-0032 AES Group
(303) 841-3922 Gilpin Engineering
(512) 220-8100 Komatsu Inc.
(817) 587-8100
ECS Southwest, LLP 713-955-1980
GIS, Inc.
(205) 941-0442
BURIAL SECTION GRADING
ENLARGEMENT SECTION 10 AND GB
CG116
LEGEND:
GRADING NOTES:
AutoCAD SHX Text
SM10A
AutoCAD SHX Text
FWS-1
AutoCAD SHX Text
SM10B
AutoCAD SHX Text
FINISHED GRADE/ SUBGRADE PITCH: 2.0% S26° 44' 01.7"W
AutoCAD SHX Text
FINISHED GRADE PITCH: 4.6% S19° 26' 49.2"E
AutoCAD SHX Text
GRAPHICAL SCALE: 1" = 10'
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
GRAPHICAL SCALE: 1" = 10'
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
IN-GROUND CREMAINS PLOTS
AutoCAD SHX Text
GRAVESITE GRID MONUMENT
AutoCAD SHX Text
PRE-PLACED CRYPTS
AutoCAD SHX Text
SECTION MARKER
AutoCAD SHX Text
PERIMETER CRYPT (TYP.)
AutoCAD SHX Text
INTERIOR CRYPT (TYP.)
AutoCAD SHX Text
LIMITS OF WORK
AutoCAD SHX Text
ELEVATION LABEL
AutoCAD SHX Text
FINISHED GRADE ELEVATION
AutoCAD SHX Text
FG
AutoCAD SHX Text
TOP OF CRYPT LID ELEVATION
AutoCAD SHX Text
TL
AutoCAD SHX Text
EXISTING CONTOUR (5' INTERVAL)
AutoCAD SHX Text
EXISTING CONTOUR (1' INTERVAL)
AutoCAD SHX Text
PROPOSED CONTOUR (5' INTERVAL)
AutoCAD SHX Text
PROPOSED CONTOUR (1' INTERVAL)
AutoCAD SHX Text
1. CONTRACTOR TO PROVIDE AMENDED SOILS ABOVE CRYPTS. 2. CONTRACTOR SHALL PROVIDE, AS A SUBMITTAL, A PROPOSED PLAN FOR CONSTRUCTING AND PERFORMING THE GRADING IN CRYPT FIELDS TO THE CEMETERY DIRECTOR FOR REVIEW AND APPROVAL. PLAN TO ADDRESS ANY POTENTIAL RAIN IMPACTS DURING EXCAVATION OF THE CRYPT FIELDS. 3. NO BACKFILL SHALL BE PLACED ON THE CRYPTS PRIOR TO BEING INSPECTED AND ACCEPTED BY THE RE THAT THE LID AND CRYPT NUMBERS MATCH.
AutoCAD SHX Text
FG 100.00 TL 98.25
AutoCAD SHX Text
LIMITS OF GRADING
AutoCAD SHX Text
UNDERDRAIN INVERT
AutoCAD SHX Text
INV
AutoCAD SHX Text
CLEANOUT INVERT OUT AND FINISHED GRADE ELEVATION LABEL
KEY MAP
(NOT TO SCALE)
CG120
POND A GRADING PLAN
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
851PC2048
FEBRUARY 7, 2020 BJS ACS Dwg. of 215
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
BID DOCUMENTS SUBMISSION
BID DOCUMENTS
321 4 5 6 7 8 9 10
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
HOUSTON NATIONAL CEMETERY
PHASE 5 DEVELOPMENT
SCP PAS
Stage h (ft) Elevation Contour Area (sf)
Contour Area (ac.)
Detention Volume (ac-Ft)
Total Volume (ac-ft)
0 0 82 87300 2.00 0 0.00 1 1.00 83 94816 2.18 0 2.09 2 1.00 84 102438 2.35 0 4.35 3 1.00 85 121958 2.80 0 6.93 4 1.00 86 142155 3.26 0 9.96
4.79 0.79 86.79 158576 3.64 0 12.69 6 1.21 88 165302 3.79 4.50 17.19 7 1.00 89 175121 4.02 8.41 21.09 8 1.00 90 185504 4.26 12.55 25.23
9 1.00 91 185504 4.26 16.80 29.49
POND A - EXISTING
Stage h (ft) Elevation Contour Area (sf)
Contour Area (ac.)
Detention Volume (ac-Ft)
Total Volume (ac-ft)
0 0 82 255579 5.87 0 0.00 1 1.00 83 264199 6.07 0 5.97 2 1.00 84 272926 6.27 0 12.13 3 1.00 85 295186 6.78 0 18.65 4 1.00 86 317967 7.30 0 25.69
4.79 0.79 86.79 332929 7.64 0 31.59 6 1.21 88 347619 7.98 9.45 41.04 7 1.00 89 357554 8.21 17.55 49.14 8 1.00 90 368729 8.46 25.88 57.48
9.5 1.50 91.5 383633 8.81 38.84 70.43
POND A - PROPOSED
KEY MAP
(NOT TO SCALE)
CG121
POND B & C GRADING PLAN
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
851PC2048
FEBRUARY 7, 2020 BJS ACS Dwg. of 215
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
BID DOCUMENTS SUBMISSION
BID DOCUMENTS
321 4 5 6 7 8 9 10
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
HOUSTON NATIONAL CEMETERY
PHASE 5 DEVELOPMENT
SCP PAS
4" HDPE
4"
HDPE
4" HDPE
4" HDPE
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
HARRIS COUNTY, TEXAS
851PC2048
FEBRUARY 7, 2020 BJS ACS
GordonPROGRAMMING AND PLANNING
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
SURVEY AND MAPPING
SECURITY CONSULTING
Dwg. of 215
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
BID DOCUMENTS SUBMISSION
BID DOCUMENTS
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
148 S. Queen Street, Suite 201
Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
HOUSTON NATIONAL CEMETERY
PHASE 5 DEVELOPMENTThe LA Group
(518) 587-8100 Aqua Engineering, Inc.
(970) 372-6104
OCMI
(202) 607-7575 rvi
(512) 480-0032 AES Group
(303) 841-3922 Gilpin Engineering
(512) 220-8100 Komatsu Inc.
(817) 587-8100
ECS Southwest, LLP 713-955-1980
GIS, Inc.
(205) 941-0442
ADA RAMP UPGRADE PLAN 1
CT101
SCALE: 1"=10'
TACTILE WARNING SURFACE AND RAMP REPLACEMENT
SCALE: 1"=10'
TACTILE WARNING SURFACE AND RAMP REPLACEMENT
SCALE: 1"=10'
TACTILE WARNING SURFACE AND RAMP REPLACEMENT
SCALE: 1"=10'
TACTILE WARNING SURFACE AND RAMP REPLACEMENT
SCALE: 1"=10'
TACTILE WARNING SURFACE AND RAMP REPLACEMENT
SCALE: 1"=10'
TACTILE WARNING SURFACE AND RAMP REPLACEMENT
SCALE: 1"=10'
TACTILE WARNING SURFACE AND RAMP REPLACEMENT
SCALE: 1"=10'
TACTILE WARNING SURFACE AND RAMP REPLACEMENT
KEY MAP
(NOT TO SCALE)
SCALE: 1"=10'
TACTILE WARNING SURFACE AND RAMP REPLACEMENT
ADA COMPLIANCE NOTE:
CONTRACTOR SHALL ENSURE ALL CURB RAMPS AND WALKWAYS ARE
COMPLIANT WITH CURRENT ADA REQUIREMENTS. CURB RAMPS ARE
NOT TO EXCEED A LONGITUDINAL SLOPE OF 8.33%. WALKWAYS ARE
NOT TO EXCEED A LONGITUDINAL SLOPE OF 5%. ALL CROSS SLOPES
ARE NOT TO EXCEED 2%. 5' X 5' LANDINGS TO BE PROVIDED AT THE TOP
OF ALL CURB RAMPS AND ARE NOT TO EXCEED A 2% SLOPE IN ANY
DIRECTION.
GRAPHIC LEGEND:
EXISTING ADA SLOPE COMPLIANT RAMPS:
EXISTING CONCRETE SLAB TO BE REMOVED
AND REPLACED WITH NEW CONCRETE SLAB
W/ TACTILE WARNING SURFACE
EXISTING ADA NON-SLOPE COMPLIANT RAMPS:
EXISTING CONCRETE RAMP AND LANDING TO
BE REMOVED AND A NEW CONCRETE RAMP
WITH LANDING TO BE INSTALLED W/ TACTILE
WARNING SURFACE
NOTE:
1. CONTRACTOR TO PATCH TO FULL DEPTH OF THE EXISTING ASPHALT
PAVEMENT SECTION FOR ANY PAVEMENT REMOVED FOR
INSTALLATION ANY PAVEMENT REMOVED FOR INSTALLATION OF
NEW CURB AND GUTTER.
SCALE: 1"=10'
TACTILE WARNING SURFACE AND RAMP REPLACEMENT
PAVEMENT REPAIR NOTES
PAVEMENT ADJACENT TO CURB
REPAIR/REPLACEMENT SHALL BE PATCHED
CONTRACTOR TO WARP GUTTER PAN ALONG RAMP
FRONTAGE TO NOT EXCEED A 5% SLOPE
AutoCAD SHX Text ±3%
AutoCAD SHX Text
G=96.1±MATCH EX.
AutoCAD SHX Text
TC=96.0±MATCH EX.
AutoCAD SHX Text
TC=96.0±MATCH EX.
AutoCAD SHX Text G=96.10
AutoCAD SHX Text
G=95.8±MATCH EX.
AutoCAD SHX Text
G=95.9±MATCH EX.
AutoCAD SHX Text G=95.90
AutoCAD SHX Text G=96.00
AutoCAD SHX Text
REPLACE EX. GUTTER IN KIND @ EX. ELEVATIONS/ENSURE FLUSH AT RAMP
AutoCAD SHX Text
INSTALL LANDING (2% MAX IN ANY DIRECTION)
AutoCAD SHX Text
APPROX. LOC. OF EX. SIDEWALK JOINT
AutoCAD SHX Text
INSTALL LANDING (2% MAX IN ANY DIRECTION)
AutoCAD SHX Text
TC=96.0±MATCH EX.
AutoCAD SHX Text
TC=96.0±MATCH EX.
AutoCAD SHX Text
APPROX. LOC. OF EX. SIDEWALK JOINT
AutoCAD SHX Text
TC=96.2±MATCH EX.
AutoCAD SHX Text
TC=96.4±MATCH EX.
AutoCAD SHX Text
TC=96.2±MATCH EX.
AutoCAD SHX Text G=96.50
AutoCAD SHX Text
G=96.3±MATCH EX.
AutoCAD SHX Text
G=96.4±MATCH EX.
AutoCAD SHX Text
G=96.4±MATCH EX.
AutoCAD SHX Text G=96.45
AutoCAD SHX Text G=96.40
AutoCAD SHX Text
G=96.1±MATCH EX.
AutoCAD SHX Text
G=96.2±MATCH EX.
AutoCAD SHX Text G=96.50
AutoCAD SHX Text
TC=96.0±MATCH EX.
AutoCAD SHX Text
TC=96.0±MATCH EX.
AutoCAD SHX Text
G=95.8±MATCH EX.
AutoCAD SHX Text
G=95.9±MATCH EX.
AutoCAD SHX Text
REPLACE EX. GUTTER IN KIND @ EX. ELEVATIONS/ENSURE FLUSH AT RAMP
AutoCAD SHX Text
G=95.8±MATCH EX.
AutoCAD SHX Text
G=95.9±MATCH EX.
AutoCAD SHX Text
TC=96.0±MATCH EX.
AutoCAD SHX Text
TC=96.0±MATCH EX.
AutoCAD SHX Text
TC=96.1±MATCH EX.
AutoCAD SHX Text G=96.10
AutoCAD SHX Text G=95.90
AutoCAD SHX Text G=96.00
AutoCAD SHX Text
INSTALL LANDING (2% MAX IN ANY DIRECTION)
AutoCAD SHX Text
INSTALL LANDING (2% MAX IN ANY DIRECTION)
AutoCAD SHX Text
APPROX. LOC. OF EX. SIDEWALK JOINT
AutoCAD SHX Text
REPLACE EX. GUTTER IN KIND @ EX. ELEVATIONS/ENSURE FLUSH AT RAMP
AutoCAD SHX Text
TC=96.2±MATCH EX.
AutoCAD SHX Text
TC=96.4±MATCH EX.
AutoCAD SHX Text
TC=96.2±MATCH EX.
AutoCAD SHX Text
G=96.4±MATCH EX.
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text
AutoCAD SHX Text
DT504
AutoCAD SHX Text
AutoCAD SHX Text
DT504
AutoCAD SHX Text
MH
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text Q
AutoCAD SHX Text R
AutoCAD SHX Text
90.90' FL 15" CPP
AutoCAD SHX Text
15" CPP
AutoCAD SHX Text
CURB INLET 96.81' TOP 91.32' (S) FL 15" CPP 91.34' (N) FL 12" CPP
AutoCAD SHX Text
DROP INLET RIM ELEVATION 96.21' 92.8' OUT (S) FL 18" R.C.P.
AutoCAD SHX Text
G=97.5±MATCH EX.
AutoCAD SHX Text
G=97.4±MATCH EX.
AutoCAD SHX Text
G=97.8±MATCH EX.
AutoCAD SHX Text
G=97.8±MATCH EX.
AutoCAD SHX Text EX. RAMP TO BE REMOVED AND REPLACED WITH NEW SLAB TO ALLOW FOR INSTALLATION OF TRUNCATED DOMES
AutoCAD SHX Text ±5%
AutoCAD SHX Text EX. RAMP TO BE REMOVED AND REPLACED WITH NEW SLAB TO ALLOW FOR INSTALLATION OF TRUNCATED DOMES
AutoCAD SHX Text ±2%
AutoCAD SHX Text
G=96.0±MATCH EX.
AutoCAD SHX Text
G=96.1±MATCH EX.
AutoCAD SHX Text
G=96.1±MATCH EX.
AutoCAD SHX Text
G=96.1±MATCH EX.
AutoCAD SHX Text EX. RAMP TO BE REMOVED AND REPLACED WITH NEW SLAB TO ALLOW FOR INSTALLATION OF TRUNCATED DOMES
AutoCAD SHX Text
G=96.4±MATCH EX.
AutoCAD SHX Text
G=96.3±MATCH EX.
AutoCAD SHX Text
G=96.6±MATCH EX.
AutoCAD SHX Text
G=96.6±MATCH EX.
AutoCAD SHX Text ±3%
AutoCAD SHX Text E
AutoCAD SHX Text EX. RAMP TO BE REMOVED AND REPLACED WITH NEW SLAB TO ALLOW FOR INSTALLATION OF TRUNCATED DOMES
AutoCAD SHX Text
G=97.1±MATCH EX.
AutoCAD SHX Text
G=97.0±MATCH EX.
AutoCAD SHX Text
G=96.8±MATCH EX.
AutoCAD SHX Text
G=96.7±MATCH EX.
AutoCAD SHX Text ±5%
AutoCAD SHX Text
G=96.7±MATCH EX.
AutoCAD SHX Text
G=96.6±MATCH EX.
AutoCAD SHX Text
G=96.6±MATCH EX.
AutoCAD SHX Text
G=96.7±MATCH EX.
AutoCAD SHX Text EX. RAMP TO BE REMOVED AND REPLACED WITH NEW SLAB TO ALLOW FOR INSTALLATION OF TRUNCATED DOMES
AutoCAD SHX Text ±2%
AutoCAD SHX Text
G=96.8±MATCH EX.
AutoCAD SHX Text
G=96.8±MATCH EX.
AutoCAD SHX Text EX. RAMP TO BE REMOVED AND REPLACED WITH NEW SLAB TO ALLOW FOR INSTALLATION OF TRUNCATED DOMES
AutoCAD SHX Text
G=96.0±MATCH EX.
AutoCAD SHX Text
G=96.1±MATCH EX.
AutoCAD SHX Text
G=96.2±MATCH EX.
AutoCAD SHX Text
G=96.2±MATCH EX.
AutoCAD SHX Text ±2%
AutoCAD SHX Text
INSTALL LANDING (2% MAX IN ANY DIRECTION)
AutoCAD SHX Text
APPROX. LOC. OF EX. SIDEWALK JOINT
AutoCAD SHX Text
G=98.0±MATCH EX.
AutoCAD SHX Text
G=98.0±MATCH EX.
AutoCAD SHX Text G=96.3
AutoCAD SHX Text G=96.3
AutoCAD SHX Text
G=95.8±MATCH EX.
AutoCAD SHX Text
G=95.8±MATCH EX.
AutoCAD SHX Text G=96.2
AutoCAD SHX Text ±7%
AutoCAD SHX Text G=96.2
AutoCAD SHX Text EX. RAMP TO BE REMOVED AND REPLACED WITH NEW SLAB TO ALLOW FOR INSTALLATION OF TRUNCATED DOMES
AutoCAD SHX Text
G=96.0±MATCH EX.
AutoCAD SHX Text
G=96.2±MATCH EX.
AutoCAD SHX Text
G=96.2±MATCH EX.
AutoCAD SHX Text
G=96.0±MATCH EX.
AutoCAD SHX Text ±3%
AutoCAD SHX Text
GRAPHICAL SCALE: 1" = 200'
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text
EM
AutoCAD SHX Text
AutoCAD SHX Text
DT503
AutoCAD SHX Text
AutoCAD SHX Text
DT503
AutoCAD SHX Text
AutoCAD SHX Text
DT503
AutoCAD SHX Text
AutoCAD SHX Text
DT503
AutoCAD SHX Text
AutoCAD SHX Text
DT503
AutoCAD SHX Text
M
E
N
S
T
O
IL
E
T
T
O
O
L
M
A
N
A
G
E
R
W
O
M
E
N
S
T
O
IL
E
T
M
E
N
S
L
O
C
K
E
R
W
O
M
E
N
S
L
O
C
K
E
R
H
O
N
O
R
G
U
A
R
D
T
O
IL
E
T
K
IT
C
H
E
N
J
A
N
IT
O
R
M
E
N
S
S
H
O
W
E
R
B
R
E
A
K
R
O
O
M
U
P
U
P
R
E
C
E
P
T
IO
N
E
L
E
C
T
R
IC
A
L
M
E
N
S
W
O
M
E
N
S
J
A
N
IT
O
R
M
E
C
H
K
IO
S
K
C
L
O
S
E
T
B
R
E
E
Z
E
W
A
Y
A
S
S
IS
T
A
N
T
D
IR
E
C
T
O
R
D
IR
E
C
T
O
R
L
O
B
B
Y
N
E
W
O
F
F
IC
E
C
O
R
R
ID
O
R
P
R
O
G
R
A
M
A
S
S
IS
T
A
N
T
P
R
O
G
R
A
M
C
L
E
R
K
J
A
N
IT
O
R
M
E
N
S
R
E
S
T
R
O
O
M
C
O
R
R
ID
O
R
W
O
M
E
N
S
R
E
S
T
R
O
O
M
W
O
R
K
S
T
A
T
IO
N
W
O
R
K
S
T
A
T
IO
N
W
O
R
K
S
T
A
T
IO
N
O
P
E
R
A
T
IO
N
S
C
E
N
T
E
R
M
E
C
H
A
N
IC
A
L
R
O
O
M
M
U
L
T
IP
U
R
P
O
S
E
R
O
O
M
H
O
N
O
R
G
U
A
R
D
A
S
S
I
S
T
A
N
T
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
HARRIS COUNTY, TEXAS
851PC2048
FEBRUARY 7, 2020 BJS ACS
GordonPROGRAMMING AND PLANNING
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
SURVEY AND MAPPING
SECURITY CONSULTING
Dwg. of 215
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
BID DOCUMENTS SUBMISSION
BID DOCUMENTS
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
148 S. Queen Street, Suite 201
Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
HOUSTON NATIONAL CEMETERY
PHASE 5 DEVELOPMENTThe LA Group
(518) 587-8100 Aqua Engineering, Inc.
(970) 372-6104
OCMI
(202) 607-7575 rvi
(512) 480-0032 AES Group
(303) 841-3922 Gilpin Engineering
(512) 220-8100 Komatsu Inc.
(817) 587-8100
ECS Southwest, LLP 713-955-1980
GIS, Inc.
(205) 941-0442
SCALE: 1"=10'
TACTILE WARNING SURFACE AND RAMP REPLACEMENT
SCALE: 1"=10'
TACTILE WARNING SURFACE AND RAMP REPLACEMENT
SCALE: 1"=10'
TACTILE WARNING SURFACE AND RAMP REPLACEMENT
SCALE: 1"=10'
TACTILE WARNING SURFACE AND RAMP REPLACEMENT
SCALE: 1"=10'
TACTILE WARNING SURFACE AND RAMP REPLACEMENT
SCALE: 1"=10'
TACTILE WARNING SURFACE AND RAMP REPLACEMENT
SCALE: 1"=10'
TACTILE WARNING SURFACE AND RAMP REPLACEMENT
KEY MAP
(NOT TO SCALE)
SCALE: 1"=10'
TACTILE WARNING SURFACE AND RAMP REPLACEMENT
NOTE:
1. CONTRACTOR TO PATCH TO FULL DEPTH OF THE EXISTING ASPHALT
PAVEMENT SECTION FOR ANY PAVEMENT REMOVED FOR
INSTALLATION ANY PAVEMENT REMOVED FOR INSTALLATION OF
NEW CURB AND GUTTER.
GRAPHIC LEGEND:
EXISTING ADA SLOPE COMPLIANT RAMPS:
EXISTING CONCRETE SLAB TO BE REMOVED
AND REPLACED WITH NEW CONCRETE SLAB
W/ TACTILE WARNING SURFACE
EXISTING ADA NON-SLOPE COMPLIANT RAMPS:
EXISTING CONCRETE RAMP AND LANDING TO
BE REMOVED AND A NEW CONCRETE RAMP
WITH LANDING TO BE INSTALLED W/ TACTILE
WARNING SURFACE
ADA RAMP UPGRADE PLAN 3
CT103
ADA COMPLIANCE NOTE:
CONTRACTOR SHALL ENSURE ALL CURB RAMPS AND WALKWAYS ARE
COMPLIANT WITH CURRENT ADA REQUIREMENTS. CURB RAMPS ARE
NOT TO EXCEED A LONGITUDINAL SLOPE OF 8.33%. WALKWAYS ARE
NOT TO EXCEED A LONGITUDINAL SLOPE OF 5%. ALL CROSS SLOPES
ARE NOT TO EXCEED 2%. 5' X 5' LANDINGS TO BE PROVIDED AT THE TOP
OF ALL CURB RAMPS AND ARE NOT TO EXCEED A 2% SLOPE IN ANY
DIRECTION.
PAVEMENT REPAIR NOTES
PAVEMENT ADJACENT TO CURB
REPAIR/REPLACEMENT SHALL BE PATCHED
CONTRACTOR TO WARP GUTTER PAN ALONG RAMP
FRONTAGE TO NOT EXCEED A 5% SLOPE
AutoCAD SHX Text
SD 48" HDPE FL ELEV: 86.52'
AutoCAD SHX Text SD GRATE INLET INV. IN ELEV (N): 86.67' INV. OUT ELEV (S): 86.65'OUT ELEV (S): 86.65'
AutoCAD SHX Text
SD CURB INLET INV. OUT ELEV (NW): 88.59'OUT ELEV (NW): 88.59'
AutoCAD SHX Text SD CURB INLET INV. IN ELEV (SE): 88.51' IN ELEV (SE): 88.51' INV. OUT ELEV (NW): 88.47'
AutoCAD SHX Text SD MANHOLE TOP RIM ELEV: 92.56' INV. IN ELEV (NE): 86.11' INV. IN ELEV (N): 87.98' INV. IN ELEV (SE): 88.03' INV. OUT ELEV (S): 86.47'
AutoCAD SHX Text SD MANHOLE TOP RIM ELEV: 92.47' INV. IN ELEV (NE): 86.64' INV. IN ELEV (N): 88.10' INV. OUT ELEV (SW): 86.55'
AutoCAD SHX Text SD MANHOLE TOP RIM ELEV: 93.15' INV. IN ELEV (NE): 86.90' INV. IN ELEV (N): 88.20' INV. IN ELEV (SE): 88.29' INV. OUT ELEV (SW): 86.86'
AutoCAD SHX Text
SD GRATE INLET INV. OUT ELEV (S): 88.33'OUT ELEV (S): 88.33'
AutoCAD SHX Text
SD GRATE INLET INV. OUT ELEV (S): 88.44'OUT ELEV (S): 88.44'
AutoCAD SHX Text
42" HDPE PIPE
AutoCAD SHX Text
42" HDPE PIPE
AutoCAD SHX Text
48" HDPE PIPE
AutoCAD SHX Text
18" HDPE PIPE
AutoCAD SHX Text
18" HDPE PIPE
AutoCAD SHX Text
SD GRATE INLET INV. OUT ELEV (S): 88.70'OUT ELEV (S): 88.70'
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text
MH
AutoCAD SHX Text
MH
AutoCAD SHX Text
MH
AutoCAD SHX Text
MH
AutoCAD SHX Text
MH
AutoCAD SHX Text
MH
AutoCAD SHX Text
MH
AutoCAD SHX Text
MH
AutoCAD SHX Text
MH
AutoCAD SHX Text
MH
AutoCAD SHX Text
MH
AutoCAD SHX Text
MH
AutoCAD SHX Text
MH
AutoCAD SHX Text
MH
AutoCAD SHX Text
MH
AutoCAD SHX Text
MH
AutoCAD SHX Text
MH
AutoCAD SHX Text
MH
AutoCAD SHX Text
MH
AutoCAD SHX Text I
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text G1
AutoCAD SHX Text G3
AutoCAD SHX Text K1
AutoCAD SHX Text K
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text J
AutoCAD SHX Text H
AutoCAD SHX Text EX. RAMP TO BE REMOVED AND REPLACED WITH NEW SLAB TO ALLOW FOR INSTALLATION OF TRUNCATED DOMES
AutoCAD SHX Text
G=96.3±MATCH EX.
AutoCAD SHX Text
G=96.3±MATCH EX.
AutoCAD SHX Text
G=96.7±MATCH EX.
AutoCAD SHX Text
G=96.7±MATCH EX.
AutoCAD SHX Text ±4%
AutoCAD SHX Text
MH
AutoCAD SHX Text
APPROX. LOC. OF EX. SIDEWALK JOINT
AutoCAD SHX Text
INSTALL LANDING (2% MAX IN ANY DIRECTION)
AutoCAD SHX Text
G=96.3±MATCH EX.
AutoCAD SHX Text
G=96.4±MATCH EX.
AutoCAD SHX Text ±2%
AutoCAD SHX Text
G=95.8±MATCH EX.
AutoCAD SHX Text
G=95.9±MATCH EX.
AutoCAD SHX Text G=96.00
AutoCAD SHX Text G=96.00
AutoCAD SHX Text G=96.10
AutoCAD SHX Text G=96.10
AutoCAD SHX Text
MH
AutoCAD SHX Text EX. RAMP TO BE REMOVED AND REPLACED WITH NEW SLAB TO ALLOW FOR INSTALLATION OF TRUNCATED DOMES
AutoCAD SHX Text
G=95.9±MATCH EX.
AutoCAD SHX Text
G=95.3±MATCH EX.
AutoCAD SHX Text
G=95.9±MATCH EX.
AutoCAD SHX Text
G=95.3±MATCH EX.
AutoCAD SHX Text ±6%
AutoCAD SHX Text
G=95.2±MATCH EX.
AutoCAD SHX Text
G=95.2±MATCH EX.
AutoCAD SHX Text
G=95.4±MATCH EX.
AutoCAD SHX Text EX. RAMP TO BE REMOVED AND REPLACED WITH NEW SLAB TO ALLOW FOR INSTALLATION OF TRUNCATED DOMES
AutoCAD SHX Text ±5%
AutoCAD SHX Text EX. RAMP TO BE REMOVED AND REPLACED WITH NEW SLAB TO ALLOW FOR INSTALLATION OF TRUNCATED DOMES
AutoCAD SHX Text
G=96.7±MATCH EX.
AutoCAD SHX Text
G=96.6±MATCH EX.
AutoCAD SHX Text
G=96.7±MATCH EX.
AutoCAD SHX Text
G=96.7±MATCH EX.
AutoCAD SHX Text ±1%
AutoCAD SHX Text
G=96.5±MATCH EX.
AutoCAD SHX Text
G=96.2±MATCH EX.
AutoCAD SHX Text
G=96.2±MATCH EX.
AutoCAD SHX Text
G=96.4±MATCH EX.
AutoCAD SHX Text EX. RAMP TO BE REMOVED AND REPLACED WITH NEW SLAB TO ALLOW FOR INSTALLATION OF TRUNCATED DOMES
AutoCAD SHX Text ±3%
AutoCAD SHX Text
REPLACE EX. GUTTER IN KIND @ EX. ELEVATIONS/ENSURE FLUSH AT RAMP
AutoCAD SHX Text EX. RAMP TO BE REMOVED AND REPLACED WITH NEW SLAB TO ALLOW FOR INSTALLATION OF TRUNCATED DOMES
AutoCAD SHX Text
G=97.0±MATCH EX.
AutoCAD SHX Text
G=97.1±MATCH EX.
AutoCAD SHX Text
G=97.1±MATCH EX.
AutoCAD SHX Text EX. RAMP TO BE REMOVED AND REPLACED WITH NEW SLAB TO ALLOW FOR INSTALLATION OF TRUNCATED DOMES
AutoCAD SHX Text
G=98.1±MATCH EX.
AutoCAD SHX Text
G=97.8±MATCH EX.
AutoCAD SHX Text
G=97.7±MATCH EX.
AutoCAD SHX Text
G=98.0±MATCH EX.
AutoCAD SHX Text ±5%
AutoCAD SHX Text
GRAPHICAL SCALE: 1" = 200'
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text
EM
AutoCAD SHX Text
AutoCAD SHX Text
DT503
AutoCAD SHX Text
AutoCAD SHX Text
DT503
AutoCAD SHX Text
AutoCAD SHX Text
DT503
AutoCAD SHX Text
AutoCAD SHX Text
DT503
AutoCAD SHX Text
AutoCAD SHX Text
DT503
AutoCAD SHX Text
NEW
ENTRANCE ROAD
MEMORIAL DRIVE EXTENSION
NEW ROAD 'A'
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
HARRIS COUNTY, TEXAS
851PC2048
FEBRUARY 7, 2020 BJS ACS
GordonPROGRAMMING AND PLANNING
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
SURVEY AND MAPPING
SECURITY CONSULTING
Dwg. of 215
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
BID DOCUMENTS SUBMISSION
BID DOCUMENTS
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
148 S. Queen Street, Suite 201
Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
HOUSTON NATIONAL CEMETERY
PHASE 5 DEVELOPMENTThe LA Group
(518) 587-8100 Aqua Engineering, Inc.
(970) 372-6104
OCMI
(202) 607-7575 rvi
(512) 480-0032 AES Group
(303) 841-3922 Gilpin Engineering
(512) 220-8100 Komatsu Inc.
(817) 587-8100
ECS Southwest, LLP 713-955-1980
GIS, Inc.
(205) 941-0442
ADA RAMP UPGRADE PLAN 2
CT102
SCALE: 1"=10'
TACTILE WARNING SURFACE AND RAMP REPLACEMENT
SCALE: 1"=10'
TACTILE WARNING SURFACE AND RAMP REPLACEMENT
SCALE: 1"=10'
TACTILE WARNING SURFACE AND RAMP REPLACEMENT
SCALE: 1"=10'
TACTILE WARNING SURFACE AND RAMP REPLACEMENT
SCALE: 1"=10'
TACTILE WARNING SURFACE AND RAMP REPLACEMENT
SCALE: 1"=10'
TACTILE WARNING SURFACE AND RAMP REPLACEMENT
KEY MAP
(NOT TO SCALE)
SCALE: 1"=10'
TACTILE WARNING SURFACE AND RAMP REPLACEMENT
NOTE:
1. CONTRACTOR TO PATCH TO FULL DEPTH OF THE EXISTING ASPHALT
PAVEMENT SECTION FOR ANY PAVEMENT REMOVED FOR
INSTALLATION ANY PAVEMENT REMOVED FOR INSTALLATION OF
NEW CURB AND…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .