017-7FX501.pdf
PDF 911 KB Posted
- Attached to
- C1NZ--Design Build Project: 629-20-118 CFM - Redesign and Repair Fire and Jockey Pump Systems
- Solicitation number
- 36C25621R0026
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Sprinkler - CEP - 3 Standpipes.pdf | ||
| CEP_L01_ALL_FP_NS_FAB.pdf | ||
| CEP_L02_ALL_FP_NS_FAB.pdf | ||
| Section 01 33 23.docx | DOCX document | |
| CEP_L03_ALL_FP_NS_FAB.pdf | ||
| CEP_L02_ALL_FP_NS_FAB.pdf | ||
| CEP_ 3 Standpipes_Sprinkler.pdf | ||
| VA PUMP 2 FIELD TEST REPORT.pdf | ||
| CEP_L04-5_ALL_FP_NS_FAB.pdf | ||
| Section 01 00 00.docx | DOCX document | |
| Section 01 35 26.docx | DOCX document | |
| CEP_L04_ALL_FP_NS_FAB.pdf | ||
| CEP_L01_ALL_FP_NS_FAB.pdf | ||
| 4. VA Master Specs Table of Contents.docx | DOCX document | |
| CEP_L03-5_ALL_FP_NS_FAB.pdf | ||
| Section 01 32 16_15.docx | DOCX document | |
| CEP_Fire_Pump_Test_Method Of Procedure 06-02-16.pdf | ||
| 015-7FX301.pdf | ||
| 016-7FX302.pdf | ||
| 36C25621R0026_1.docx | DOCX document | |
| VA PUMP 1 field test report.pdf | ||
| Section 00 11 21.docx | DOCX document | |
| General Decision LA 20200041 10-09-2020.pdf | ||
| EXHIBIT A CONTRACTOR EVALUATION FORM CONSTRUCTION SAFETY.pdf |
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
7-L1 100' - 0"
7-L2 122' - 8"
07 3
LEVEL 01 (01-08)
MASTER
100' - 0"
LEVEL 02 (04)
114' - 2"
LEVEL 02 (05)
112' - 8"
LEVEL 02 (07)
122' - 8"
Level 1 100'-0"
Level 2 122'-8"
LEVEL 1
MEZZANINE
110'-8"
Level 1
T.O.S. EL. 100' - 0"
Level 2
T.O.S. EL. 122' - 8"
3.1
Elev.
#1
Alarm Valve
Elev.
#2
Alarm Valve
Vault Alarm Valve
1 1/2" FIRE MAIN
TO ELEVATOR PIT
AREAS
4" FIRE MAIN TO
PUMP VAULT AREA
ALARMED SHUT-OFF VALVE
LOCKED IN THE 'OPEN'
POSITION.
1 1/2"ø
1 1/2"ø
4"ø
4"ø
PROVIDE A SIGN
DESIGNATION FOR EACH
VALVE INDICATING AREA
OF SERVICE.
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
T E
R
IN
C H
O
N E
FO
O
T O
N E
H
AL
F I N
C H
O
N E
FO
O
T
TH
R
EE
Q U
A R
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
EE
T
( 1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
XT
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
E S
O N
E
FO
O T
6"
BUILDING NUMBER
NEW ORLEANS, LOUISIANA
7FX501
SCHEDULES AND DETAILS
CRS MJOctober 31, 2011
7629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
SCHRENK & PETERSON / CIVIL
KORDA/NEMETH ENGINEERS / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE
ARCHITECURAL ENGINEERS / PLUMBING
SCALES & ASSOCIATES INC. / FIRE PROTECTION
COMMUNICATION DESIGN GROUP / LOW VOLTAGE
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
PYBURN & ODOM / ABATEMENT
Department of Veterans Affairs
OFFICE OF
CONSTRUCTION
MANAGEMENTEWP_07
CONSTRUCTION DOCUMENTS 1
FULLY SPRINKLERED
PIPE SLEEVE THROUGH CONCRETE WALL3 TYPICAL DRAIN DETAIL4 PIPE SLEEVE THROUGH ARCHITECTURAL PARTITION5
VERTICAL PIPE PENETRATION DETAIL6 FIRE DEPARTMENT CONNECTION DETAIL7
TYPICAL UPRIGHT SPRINKLER HEAD DETAIL1 TYPICAL PEDANT SPRINKLER HEAD DETAIL2
UNDERGROUND FIRE MAIN SERVICE DETAIL8
3 BULLETIN 007 7/20/12
1/2" = 1'-0"1 FIRE PROTECTION RISERS IN LOBBY
THIS DETAIL WAS
ADDRESSED IN RFI-411
BEFORE BULLETIN 007
File details come from the government source that posted it. Updated .