Y1DA--Project620-22-110 Replace and Upgrade Fire alarm System at Montrose VAMC
Open Solicitation Posted
Not the latest version. See the latest solicitation from .
- Solicitation number
- 36C24227B0009
- Agency
-
Veterans Integrated Service Network 2
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 561621 Security Systems Services (except Locksmiths)
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs Veterans Health Administration VISN 2 seeks to replace and upgrade the fire alarm system at Montrose Veterans Affairs Medical Center under Project 620-22-110, with proposals due December 16, 2026. The Set Aside line reads "No Set-Aside Used."
Work covers 28 existing buildings plus two new buildings, CLC and 7B, on the medical center campus. The attached specifications summary describes fully addressable, non-proprietary systems with fire alarm control panels in each building, the Fire Department (Building 19) as primary master station, and Building 20 (Boiler Plant) as secondary master station. The bid is itemized by building with a base bid and three alternates: Alternate 1 removes CLC work, Alternate 2 removes CLC and Building 7B work, and Alternate 3 relocates the Building 24 control panel to a different room. The phasing plan spans 76 work weeks across 532 calendar days in 27 phases.
Post-award requirements include a 5-year repair and maintenance agreement covering parts and labor, plus two full days of on-site training by factory-trained manufacturer representatives for up to ten Fire Department and Electrical personnel. Work must be performed by licensed and factory-authorized fire alarm installers or registered apprentices, in compliance with OSHA, VA security, infection control, and hot work requirements. Every contractor and subcontractor employee must complete an OF-306 submission and fingerprinting within five business days of post-award instructions, and no employee may begin work before a favorable screening determination.
Two certifications are decision-critical. The VA 852.219-75 Notice of Limitations on Subcontracting certificate, with the special trade construction option checked, caps payments to non-certified SDVOSB and VOSB firms at 75% of government payments. Failure to return the executed certification renders the offer ineligible for evaluation and award. Offerors must also certify end-product origin under FAR 52.225-2, the Buy American Certificate.
The NAICS code is 561621, Security Systems Services (except Locksmiths), and the PSC is Y1DA, Construction of Hospitals and Infirmaries. The attached prevailing wage determination NY20260017 covers Westchester County, New York, effective 05/18/2026.
Notice text
See attached
Files
Notice history
| Notice | Type | Posted |
|---|---|---|
| Y1DA--Project620-22-110 Replace and Upgrade Fire alarm System at Montrose VAMC | Solicitation | |
| This notice | Solicitation | |
| Y1DA--Project620-22-110 Replace and Upgrade Fire alarm System at Montrose VAMC | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Z1DA--Upgrade Fire Alarm System Construction 676-22-110 | Veterans Integrated Service Network 12 | Service-Disabled Veteran-Owned Small Business | |
| C1DA--Project # 596A4-27-101 - A/E Upgrade Fire Alarm System | Veterans Integrated Service Network 9 | Service-Disabled Veteran-Owned Small Business | |
| CTX Life Safety Assessment and Fire Damper Inspection | Veterans Integrated Service Network 17 | Service-Disabled Veteran-Owned Small Business | |
| Fire Alarm Panel Replacement(s) | Bureau of Reclamation | No set-aside | |
| Connect Maglocks to Fire System, B6040 | Naval Facilities Engineering Command | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity