Request for Information_JBSA FSH HVAC Replacement
Closed Pre-Solicitation Posted
Not the latest version. See the latest solicitation from .
- Solicitation number
- F2M3CB6043A001
- Agency
-
Air Education and Training Command
Air Force, Department of Defense
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 238220 Plumbing, Heating, and Air-Conditioning Contractors
- PSC
- 4120 Air Conditioning Equipment
- Place of performance
- Jbsa Ft Sam Houston, Texas 78234, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The Air Force Air Education and Training Command is preparing to procure HVAC system replacement at Joint Base San Antonio–Fort Sam Houston (JBSA-FSH) and is soliciting market information from small businesses through an RFI due May 16, 2026. The procurement targets NAICS code 238220 (Plumbing, Heating, and Air-Conditioning Contractors) with a $19 million size standard and anticipates a Firm Fixed Price award.
Work is performed at two locations: Building 590 (2539 Old Austin Rd) and Building 591 (2611 Old Austin Rd), both ZIP 78234, for the 502d Civil Engineer Squadron. The scope involves life-cycle replacement of existing SPX ReCold Model MW-30C cooling tower HVAC systems with "brand name or equal" systems meeting or exceeding current performance and dimensional specifications. The contractor must provide all project management, supervision, labor, tools, materials, equipment, and quality control to deliver fully commissioned and operational systems compliant with all applicable codes, standards, and manufacturer specifications.
Technical requirements include two fluid coolers rated for 208/230V three-phase power with dual fans approximately 3.0 HP each and internal basin heater approximately 4.0 KW; two circulation pumps delivering minimum 120 GPM with 5 HP continuous duty motors at standard four-pole speed (approximately 1750-1760 RPM); and two control panels rated for 208/120V three-phase, four-wire service with 100A main breaker and two 20A three-pole breakers in NEMA 3R outdoor-rated enclosures. Contractor personnel must obtain base identification passes and comply with Air Force installation security, AFOSH standards, and OSHA lockout/tagout procedures. Work hours are Monday–Friday, 0700–1700 hours CST (excluding Federal holidays), with minimum five-day advance notice required before delivery and onsite work. The contractor must provide a one-year comprehensive warranty on all materials and labor commencing upon final acceptance.
Respondents must submit completed RFI questionnaires and capability statements (limited to five pages) by May 15, 2026 to Contract Specialist SrA Jamie Cutright (jamie.cutright@us.af.mil) and Contracting Officer Emily Rodriguez (emily.rodriguez.8@us.af.mil). The RFI is for acquisition planning purposes only; no evaluation results will be issued to respondents.
Notice text
THIS IS NOT A REQUEST FOR QUOTE: The purpose of this Sources Sought Notice is to query the market for potential interested, capable, responsible, and qualified small businesses that can provide and perform the stated requirement IAW the atatched DRAFT Statement of Work. The Government is interested in collecting market information in accordance with (IAW) RFO Part 10. If interested, please review all attachments and fill out and return a copy of the attached Request For Information (RFI) document along with your capabilities.
Please note that this is not a construction requirement.
Please return the filled out RFI and capability statement to the POCs in this notice.
Description of Services: The contractor shall provide all personnel, equipment, tools, materials, supervision, and quality control necessary for the life-cycle replacement of the HVAC systems at Buildings 590 and 591. The project requires the replacement of the existing systems (SPX ReCold, Model: MW-30C, Serial: MW-10063716-A2) with a "brand name or equal" system. All work will be performed for the 502d Civil Engineer Squadron (502CES) at JBSA-FSH. The objective is to deliver a complete, commissioned, and fully operational HVAC system at each location, in accordance with (IAW) all applicable codes, standards, and manufacturer specifications.
Attachments:
1. Request for Information_JBSA FSH HVAC Replacement (fill out)
2. DRAFT SOW - JBSA FSH HVAC Replacement_11May26
3. DRAFT Salient Characteristics - FLUID COOLERS AND PUMPS
Files
| File | Type | Posted |
|---|---|---|
| DRAFT Salient Characteristics - FLUID COOLERS AND PUMPS.docx | DOCX document | |
| DRAFT SOW - JBSA FSH HVAC Replacement_11May26.docx | DOCX document | |
| Request for Information_JBSA FSH HVAC Replacement.docx | DOCX document | |
| DRAFT SOW - JBSA FSH HVAC Replacement_11May26.docx | DOCX document | |
| DRAFT Salient Characteristics - FLUID COOLERS AND PUMPS.docx | DOCX document | |
| Request for Information_JBSA FSH HVAC Replacement.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| Purchase and installation of two (2) Closed-Circuit Fluid Coolers and Associated Pumps | Solicitation | |
| This notice | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Troubleshoot & Repair of Portable Chillers Service Requirement | Air Education and Training Command | Total Small Business | |
| Brand Name or Equal - WaterFurnace Model: UBH015R for B3631 & B3635 - Turnkey Replacement | Air Education and Training Command | No set-aside | |
| Repair Mechanical Systems IDIQ (FY 27-32) | AFLCMC Wright Patterson AFB | No set-aside | |
| J041--Trane BAS HVAC Control System Inspection, Maintenance, Upgrades, and Repair | Veterans Integrated Service Network 19 | No set-aside | |
| Two sets of HVAC units or Mobile Ground Control Station | Shared Services Center | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity