This solicitation seeks to replace HVAC systems and controls at facility B49904 located at Cape Canaveral Space Force Station, Florida for the Department of the Air Force Space Command. The scope of work includes replacing an 80-ton chiller, installing a new 2-ton mini-split heat pump system, upgrading controls through installation of new temperature sensors and replacement of six air handler and one VAV controller. Proposals were due by September 20, 2022 and bids were opened via teleconference on the same date with amounts ranging from $329,772.72 to $458,002.
The solicitation is set aside for Woman Owned Small Businesses under NAICS code 238220 for specialty trade contracting with a size standard of $16.5 million. The place of performance is Cape Canaveral AS, FL and the work is to be completed within 180 days of notice to proceed.
Notice text
Project DBEH 22-1578; The work to be performed consists of Replacing chiller and install Split System at facility B49904 to include the following. In east UPS Room remove the 12" flex duct that is hanging from the duct work and seal hole in the duct system and re-insulate the duct. Install 2 ton mini split system on the east wall exterior and wall evaporator on the inside wall. Carrier will
be sufficient for mini split system. Need a Controls contractor to install a temperature sensor in the duct system prior to VAV-11 and reprogram VAV-11 to close damper if the supply air temperature increases over 60 degrees. Reprogram the heater element in the VAV box not to operate. Replace 6 Metasys controllers with EMCS controllers on the following air handlers and one VAV: AHU-1, AHU-6, AHU-10, AHU-11 AHU-12 and AHU-15 and VAV-11. Replace Niagara Jace with EMCS ASP building.