Replace SAB HVAC

Pre-Solicitation Posted

A newer solicitation was posted. See the latest solicitation from .

Solicitation number
FA252122B0017
Agency
Air Force Space Command Air Force, Department of Defense
Responses due
Not on record
Set-aside
Service-Disabled Veteran-Owned Small Business

Opportunity facts

NAICS code
238220 Plumbing, Heating, and Air-Conditioning Contractors
PSC
Z2QA Repair Or Alteration Of Restoration Of Real Property (Public Or Private)
Place of performance
Canaveral Air Station, Florida 32925, United States

Notice details come from SAM.gov. Updated .

About this opportunity

This pre-solicitation notice announces the Air Force's intent to replace the HVAC system at Facility B49904 located at Cape Canaveral Space Force Station, Florida. The scope of work includes replacing an 80-ton chiller, installing a 2-ton mini split system, and upgrading various air handler and building controllers to the EMCS platform. Interested parties are advised to monitor SAM.gov on or around August 15th for solicitation FA252122B0017, which will be issued as an invitation for bid evaluated on lowest price technically acceptable basis. The period of performance is 180 calendar days from the notice to proceed.

The acquisition is set aside exclusively for service-disabled veteran-owned small businesses. The predominant NAICS code is 238220 - Plumbing, Heating, and Air-Conditioning Contractors while the applicable PSC code is R499 - Operation and Maintenance of Buildings. No incumbent is named but the replacement chiller equipment is specified as a Trane product. The pre-solicitation notice does not provide an estimated contract value or budget but the scope of replacing an entire HVAC system suggests an award in the mid-to-high six figure range.

Notice text

Project DBEH 22-1578; The work to be performed consists of Replacing chiller and install Split System at facility B49904 to include the following. In east UPS Room remove the 12" flex duct that is hanging from the duct work and seal hole in the duct system and re-insulate the duct. Install 2 ton mini split system on the east wall exterior and wall evaporator on the inside wall. Carrier will be sufficient for mini split system. Need a Controls contractor to install a temperature sensor in the duct system prior to VAV-11 and reprogram VAV-11 to close damper if the supply air temperature increases over 60 degrees. Reprogram the heater element in the VAV box not to operate. Replace 6 Metasys controllers with EMCS controllers on the following air handlers and one VAV: AHU-1, AHU-6, AHU-10, AHU-11 AHU-12 and AHU-15 and VAV-11. Replace Niagara Jace with EMCS ASP building controller complete with graphical interface. Replace all Distect controllers with EMCS Controllers. Replace 80 ton chiller on south side with a new Trane chiller. Coils to be coated with Blygold Coating. Cut supply and return lines to the first set of valves. Re-insulate after piping secured. All electrical requirements shall be field verified. Operate and test the new mini split and chiller and make sure they are fully operational.

Attachments

Files attached to this notice, newest first
File Type Posted
22B0017 Presolicitation Notice.pdf PDF

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted
Replace SAB HVAC Latest solicitation Solicitation
Replace SAB HVAC This notice · Original Pre-Solicitation

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity