This federal contract opportunity is for the replacement of two computer room air conditioning (CRAC) systems in Building 250 at the Dam Neck Annex in Virginia Beach, Virginia. The Department of the Navy, Naval Facilities Engineering Command (NAVFAC) is seeking proposals to remove the existing 26-ton DX split-type CRAC systems and install two new non-ducted, air-cooled, split-type CRAC systems. The project also requires coordination and modification to the building's architectural, electrical, and fire protection systems. Proposals are due on September 30, 2024, and the contract will be awarded to the responsible offeror with the lowest price. A mandatory site visit is scheduled for September 11, 2024, and the proposal deadline for Pre-Proposal Inquiries is September 17, 2024.
This solicitation is limited to contractors on the relevant Multiple Award Construction Contract (MACC) group. The estimated price range for the project is between $500,000 and $1,000,000, and the contract completion date is 540 calendar days. The place of performance is the Dam Neck Annex in Virginia Beach, Virginia.
Notice text
This project will provide for removal of two DX, nominal 26 ton air cooled split type Computer Room Air Conditioning (CRAC) systems. Each system consists of a Stulz model No. VFS–312–DAR-U indoor unit and SCS-312 remote air cooled condensing unit. The condensing units are located on the roof of B-250, which is a two story building. The associated refrigerant piping and ductwork shall also be removed. Two new non-ducted, air cooled, split type CRAC systems configured for upflow air discharge, each sized for the indicated IT equipment heat dissipation and room envelope loads shall be provided. The intent is to provide a lead/lag arrangement and locate the new indoor units in the same approximate location as the existing units. All building systems such as Architectural, Electrical, Fire Protection will be coordinated and modified to accommodate the mechanical renovation workThis project will provide for removal of two DX, nominal 26 ton air cooled split type Computer Room Air Conditioning (CRAC) systems. Each system consists of a Stulz model No. VFS–312–DAR-U indoor unit and SCS-312 remote air cooled condensing unit. The condensing units are located on the roof of B-250, which is a two story building. The associated refrigerant piping and ductwork shall also be removed. Two new non-ducted, air cooled, split type CRAC systems configured for upflow air discharge, each sized for the indicated IT equipment heat dissipation and room envelope loads shall be provided. The intent is to provide a lead/lag arrangement and locate the new indoor units in the same approximate location as the existing units. All building systems such as Architectural, Electrical, Fire Protection will be coordinated and modified to accommodate the mechanical renovation work.
ONLY CONTRACTORS ON THIS MACC GROUP CAN SUBMIT A PROPOSAL.
Files
| File | Type | Posted |
|---|---|---|
| ARGUS PPI Spreadsheet Responses (002).pdf | ||
| 24R2828 AMENDMENT 0001.pdf | ||
| ReiBaron PPI Responses.pdf | ||
| MIGGOV2 PPI Spreadsheet Responses.pdf | ||
| MIGGOV PPI Spreadsheet Responses.pdf | ||
| DEVGRU Contractor Access Instructions - DEVGRU Contract.docx | DOCX document | |
| 1809025 Final DB-RFP.pdf | ||
| BASE ACCESS INSTRUCTION.pdf | ||
| DEVGRU SPREADSHEET.xlsx | XLSX spreadsheet | |
| WD va167 (1).txt | TXT text file | |
| N4008524R2828 GENERAL REQUIREMENTS .pdf | ||
| SECNAV 5512.pdf | ||
| Oceana IDIQ Front End SPECS - 20220602.pdf | ||
| ATTACHMENT F PPI Spreadsheet.xlsx | XLSX spreadsheet | |
| PROVISION 52.204-24.pdf | ||
| BLANK SPONSOR VERIFICATION SPREADSHEET.xls | XLS spreadsheet |
Show all 16
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Replace HVAC System and Components at CAD593 | Naval Facilities Engineering Command | Total Small Business | |
| CRAC Maintenance Service | Ohio National Guard | Total Small Business | |
| Rental of AC Unit with Heaters | Naval Sea Systems Command | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity