J061--Emergency Switchgear Repairs PWS 539
Open Pre-Solicitation Posted
Not the latest version. See the latest pre-solicitation from .
- Solicitation number
- 36C25027Q0125
- Agency
-
Veterans Integrated Service Network 10
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 811310 Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
- Place of performance
- Cincinnati Vamc 3200 Vine Street, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Cincinnati VA Medical Center, within Veterans Integrated Service Network 10 of the Department of Veterans Affairs' Veterans Health Administration, is preparing to procure emergency switchgear repairs under solicitation 36C25027Q0125, with capability responses due December 7, 2026. The notice is a sources sought for market research only, with no set-aside used, and it instructs firms not to submit proposals or questions. Responses go by email to ronald.heidemann@va.gov and must include the firm's name, socio-economic status, whether it holds a contract vehicle the VA can order against, and any alternative NAICS code with supporting documentation. The requirement is coded NAICS 811310 and PSC J061.
Per the attached Performance Work Statement summary, work is performed at Building 1, Room B013, Cincinnati VA Medical Center, 3200 Vine Street, Cincinnati, Ohio 45220-2637. The effort is a firm-fixed-price design-build project to repair two Kohler 1500REOZDC generators rated 1,560 kW each, replace MFR13 and reverse power protective relays, modify switchgear door and wiring, program and test replacement relays, and conduct load-bank testing at 30%, 50%, and 75% generator nameplate kW. The period of performance is 120 days, with generator work scheduled on separate weekends, one generator per weekend. The contractor must supply all labor, materials, parts, and load banks, provide a licensed Professional Engineer for engineering oversight, carry commercial general liability insurance of $1,000,000 minimum per occurrence, and obtain facility access approval and VAMC badges for all personnel.
An attached July 27, 2026 email, per its summary, states the VA determined an MFR13 relay upgrade is the only viable solution and that total project cost exceeds the initial estimate. The PWS names ABB business development manager Fred Ervin (614-560-3216, fred.ervin@us.abb.com) as point of contact. Attached 2023 ABB records document prior work on this switchgear under Project 4126174.
Notice text
The Cincinnati Veterans Administration Medical Center (VAMC) has a requirement to provide repairs to generator operation to address failed generators & associated paralleling switchgear.
The intention of this Sources Sought is to obtain information only. Please do not send a proposal or questions.
Requested information:
To aid acquisition planning, we re seeking capable and interested firms for the information requested. If your firm meets the criteria please send the point of contact (ronald.heidemann@va.gov) the following, via email:
Firm s Name
Socio-Economic Status
Whether or not your company has a contract vehicle we can order against
If your company believes there is an alternative NAICS code please provide this
Please attachments for more information.
Files
Show all 12
Notice history
| Notice | Type | Posted |
|---|---|---|
| J061--Emergency Switchgear Repairs PWS 539 | Pre-Solicitation | |
| This notice | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| V301--539 - Fifth Floor Pharmacy Move Service Contract | Veterans Integrated Service Network 10 | No set-aside | |
| APT Generator Switchgear Testing – Alvin C. York VA Medical Center | Veterans Integrated Service Network 9 | No set-aside | |
| Z1DA--Project No. 583-22-106- Replace Electrical Panels & Expand Distribution. | Veterans Integrated Service Network 10 | No set-aside | |
| H259--Essential Electrical System (EES) Switch Gear Testing | Veterans Integrated Service Network 22 | Service-Disabled Veteran-Owned Small Business | |
| Automatic Transfer Switch (ATS) Preventive Maintenance and Repair Services, and Isolation Power Panel Inspection | Veterans Integrated Service Network 15 | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity