APT Generator Switchgear Testing – Alvin C. York VA Medical Center
Open Pre-Solicitation Posted
- Solicitation number
- 36C249-27-AP-1027
- Agency
-
Veterans Integrated Service Network 9
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 541380 Testing Laboratories and Services
- Place of performance
- Murfreesboro, Tennessee, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs, Network Contracting Office 9, seeks capable sources for one-time diagnostic testing of APT generator switchgear at the Alvin C. York VA Medical Center in Murfreesboro, Tennessee, with email responses due November 24, 2026, at noon CT. No set-aside is used. This is market research only, not a solicitation or commitment to award, and no pricing is requested.
Anticipated classification is NAICS 541380, Testing Laboratories and Services, with a $19 million size standard, and PSC H261. Required work includes testing three current transformers, two sets of potential transformers, and one SEL-351A protective relay; providing up to eight technician hours to investigate reverse kVAR trips; and submitting a written report with findings and recommendations. The SOW summary specifies electrical tests including insulation resistance, polarity, ratio verification, excitation/saturation, dielectric withstand, and burden measurements, performed by certified trained technicians wearing contractor identification badges.
The SOW summary states a period of performance of six months from award, completed during two site visits Monday through Friday, 7:00 a.m. to 3:30 p.m., with extended hours available upon Contracting Officer's Representative approval. The contractor supplies all transportation, labor, parts, materials, tools, equipment, and PPE compliant with OSHA standards and NFPA 70E, and the contract carries a one-year warranty from acceptance. The COR is Steven Burton, Electrical Supervisor.
Responses must be emailed to shania.kimbrough@va.gov with the subject "APT Generator Switchgear Testing" and include company name, UEI, point of contact, business size and applicable SBA certification, relevant testing experience, and availability. Respondents must state whether they would quote if solicited, identify who would perform field testing, and indicate whether they need special software or access to the existing relay.
Notice text
The Department of Veterans Affairs, Network Contracting Office 9, seeks capable sources for one-time diagnostic testing of APT generator switchgear at the Alvin C. York VA Medical Center in Murfreesboro, Tennessee.
The work includes testing three current transformers, two sets of potential transformers, and one SEL-351A protective relay; providing up to eight technician hours to investigate reverse kVAR trips; and submitting a written report with findings and recommendations.
Anticipated classification: NAICS 541380, Testing Laboratories and Services ($19 million size standard); PSC H261.
Interested firms should email shania.kimbrough@va.gov by November 24, 2026, at noon CT, using the subject APT Generator Switchgear Testing. Include your company name, UEI, point of contact, business size and applicable SBA certification, relevant testing experience, and availability. State whether you would quote if solicited, who would perform the field testing, and whether you need any special software or access to the existing relay.
This notice is for market research only. It is not a solicitation or a commitment to award. No pricing is requested.
Files
| File | Type | Posted |
|---|---|---|
| SOW Qualus test APT Generator Switch gear.doc | DOC document |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| J061 UPS and Battery Maintenance and Testing – Nashville VA Medical Center | Veterans Integrated Service Network 9 | No set-aside | |
| J061--586-Switchgear and ATS Investigation and Repair Service (VA-27-00015294) | Veterans Integrated Service Network 16 | No set-aside | |
| J061--Triennial Circuit Breaker and Feeder Testing | Veterans Integrated Service Network 21 | Service-Disabled Veteran-Owned Small Business | |
| J061--TVHS Generator PM/Bank Testing Base+4 | Veterans Integrated Service Network 9 | Service-Disabled Veteran-Owned Small Business | |
| 36-Month Electrical Distribution Testing | Veterans Integrated Service Network 7 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity