J059--Posting Answers to Vendor Questions - Core Lab Electrical Upgrade Install - DC VAMC 688-24-3-459-0307

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
36C24524Q0670
Agency
Responses due
Set-aside
Service-Disabled Veteran-Owned Small Business

Opportunity facts

Place of performance
Department of Veterans Affairs Washington Dc Va Medical Center Washington DC, District of Columbia 20422, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs, Veterans Health Administration, Veterans Integrated Service Network 5 is seeking quotes for an electrical upgrade installation project at the Washington DC Veterans Affairs Medical Center (DC VAMC) Core Lab. The contractor shall furnish all labor, materials, and management to install electrical wiring, conduit, a 40 KVA uninterruptible power supply (UPS), transfer switches, and a new electrical panelboard to power new medical equipment in Suite GB 200. The work includes interfacing the new electrical system to the existing emergency power supply. Qualified contractors must be licensed master electricians with at least 5 years of experience working on electrical systems at VA medical facilities. Quotes are due by July 15, 2024 at 10:00 AM EST and will be evaluated based on technical qualifications, past performance, and price.

This procurement is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB). The contract will be awarded as a firm-fixed-price purchase order to the contractor providing the best value. The project involves installing power distribution and interfacing to the 40 KVA UPS to support new lab equipment in Suite GB 200 at the DC VAMC located at 50 Irving St NW, Washington, DC 20422.

Notice text

2 versions

Update #2 · Latest ·

AMENDMENT TO RFQ 36C24524Q0670 0001

POSTING ANSWERS TO VENDOR QUESTIONS

Update #1 ·

REQUEST FOR QUOTES 36C24524Q0670

At the Washington DC Veterans Affairs Medical Center (DC VAMC) the Core Lab is installing new processing equipment on the basement floor in Suite GB 200. With the new equipment existing emergency power needs the have a Power Bridge consisting of a 40 KVA Uninterruptable Power Supply (UPS). The UPS will be supplied by an existing feeder and circuits will be routed from a new panelboard supplied by the output of the UPS. The electrical circuits for these locations are detailed in the following scope. Additionally, each piece of equipment will require power poles with power as specified in the attached details. The Electrical Contractor under this requirement shall install the power as outlined below in the scope to include distribution and interfacing to an 40KVA UPS in the closet in room GB 220, power to be installed per space plan attached in Suite GB 200.

Files

File Type Posted
Final plan.pdf PDF
PowerVar 3300 users manaul A01-00134 3300 REV F 4-5-21.pdf PDF
ANSWERS TO VENDOR QUESTIONS - 36C24524Q0670.pdf PDF
3300 Series Footprint and Clearance Requirements.pdf PDF
UPS Specs.pdf PDF
36C24524Q0670 0001_1.docx DOCX document
Power Conditioning Distribution Unit.pdf PDF
36C24524Q0670 0001.pdf PDF
Wage Determination Washington D.C.pdf PDF
36C24524Q0670 -.pdf PDF
36C24524Q0670_1.docx DOCX document
Show all 11

Notice history

Notice Type Posted
J059--notice of award 36C24524P0779 - core lab electrical upgrade DC VAMC Award Award Notice
This notice Latest solicitation Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Z1DA--Project No. 583-22-106- Replace Electrical Panels & Expand Distribution. NAICS 238210 Veterans Integrated Service Network 10 No set-aside
J061--triennial electrical maintenance - amendment 4 POP: 12/01/2026 - 11/30/2027 plus 4 option years Slvhcs New Orleans, Louisiana 70119, United States · NAICS 238210 Veterans Integrated Service Network 16 Service-Disabled Veteran-Owned Small Business
36-Month Electrical Distribution Testing Georgia 30033, United States · NAICS 221122 Veterans Integrated Service Network 7 Service-Disabled Veteran-Owned Small Business
J059--FY27 Electrical Test and Calibrations Department of Veterans Affairs Syracuse VA Medical Center Syracuse NY 13210 · NAICS 238210 Veterans Integrated Service Network 2 No set-aside
Correct Electrical Deficiencies Fayetteville, North Carolina 28301, United States · NAICS 236220 Veterans Integrated Service Network 6 Service-Disabled Veteran-Owned Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors