J012--Fire Door Assembly Survey, Inspection and Repair

Closed Solicitation Posted

Solicitation number
36C24126Q0632
Agency
Responses due
Set-aside
Service-Disabled Veteran-Owned Small Business

Opportunity facts

NAICS code
541350 Building Inspection Services
Place of performance
White River Junction Vamc White River Junction, Vermont 05009, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Veterans Health Administration seeks fire door assembly survey, inspection, and repair services at White River Junction VAMC in Vermont, with quotes due August 7, 2026 at 5:00 PM EST. This is an SDVOSB set-aside under NAICS 541350, with a small business size standard of $11.5 million.

Place of performance is White River Junction VAMC, 163 Veterans Drive, White River Junction, Vermont. The requirement covers approximately 300 fire door assemblies across 39 buildings on a 64-acre campus. All personnel performing inspections must be certified technicians with recognized credentials such as QFDI (Qualified Fire Door Inspector), CFDAI, or NFPA Certified Fire Inspector I (CFI-I). Work must comply with current NFPA 80 and NFPA 101 standards.

The base year contract includes a campus-wide survey (baseline event only), annual inspection services and reporting, and estimated repairs with a $7,000 annual contingency. Survey and initial inspections must be completed within three months of award. The contract includes four one-year option periods. Offerors must provide cost-per-door pricing for additional survey and inspection services should more than 300 doors be identified. The Government intends to award firm-fixed price.

Evaluation factors are price, past performance (minimum one to three references for similar work), and technical capability demonstrating corporate experience, technician qualifications, and approach to meet Statement of Work requirements. Award will be based on best value under FAR Part 13.106-2(b).

Questions are due July 20, 2026 at 5:00 PM EST. A mandatory site visit is scheduled for July 16, 2026 at 10:00 AM. Offerors must be registered in System for Award Management (SAM) and VISTA prior to award. Submitted quotations must include a completed Price Schedule and Past Performance Worksheet. The solicitation is issued as RFQ 36C24126Q0632 with quotes submitted electronically to Kenya.Mitchell1@va.gov. Service Contract Labor Standards apply with Wage Determination 2015-4139 Revision 33. SDVOSB firms must certify compliance with 50% subcontracting limitations on non-certified SDVOSB or VOSB firms.

Notice text

3 versions

Update #3 · Latest ·

Combined Synopsis-Solicitation for Commercial Products and Commercial Services

Effective Date: 04/18/2025

Revision: 02

THE PURPOSE OF THIS AMENDMENT IS TO:

Provide responses to questions received

Update FAR 52.212-1

Remove FAR 52.212-2

Add FAR Part 13.106-2(b) -- Evaluation of Quotations

Update highlighted sections of solicitation

Extend response due date to August 7, 2026 @ 5:00PM EST

Description

(i) This is a combined synopsis/solicitation for commercial items prepared in accordance with

the format in Subpart 12.6, as supplemented with additional information included in this notice.

This announcement constitutes the only solicitation; proposals are being requested and a written

solicitation will not be issued.

(ii) The solicitation number is 36C24126Q0632 and the solicitation is issued as a request for

quotation (RFQ).

(iii) A statement that the solicitation document and incorporated provisions and clauses are those

in effect through Federal Acquisition Circular 2026-01.

(iv) This requirement is being issued as a SDVOSB set-aside. The associated NAICS

541350 and small business size standard is $11.5 million.

(v) The Government intends to award a firm-fixed price award for Fire Door Assembly Survey, Inspection and Repair Services at White River Junctions VAMC. Please see the attached Performance Work Statement for full requirement details. Please complete the Price Schedule below and submit with the quote submission.

(vi) The Contractor shall provide all resources necessary to provide Fire Door Assembly Survey, Inspection and Repair Services IAW the attached (Performance Work Statement). Please see the attached PWS for full requirement details.

(vii) The Place of Performance is White River Junction VAMC as described per the (Performance Work Statement).

(viii) Provision at 52.212-1, Instructions to Offerors -- Commercial, applies to this acquisition in

addition to the following addenda s to the provision: 52.252-1 Solicitation Provisions

Incorporated by Reference (FEB 1998); 52.204-7 System for Award Management (OCT 2018);

52.204-16 Commercial and Government Entity Code Reporting (JUL 2016); 52.217-5

Evaluation of Options (JUL 1990); 852.252-70 Solicitation Provisions or Clauses Incorporated

by Reference (JAN 2008)

(ix) Provision at 52.212-2, Evaluation -- Commercial Items, applies to this requirement.:

Site Visit: July 16, 2026 @ 10:00 AM

Address: 163 Veterans Drive, BLDG 37

White River Junction, VT

Postal Code: 05009

POC: James Kirkpatrick

Submission of Quotes:

(1) Quotes shall be received on or before the date and time specified in Section (xv) of this

solicitation. Note: Offers received after the due date and time shall not be considered.

(2) Offerors shall submit their quotes electronically via email to Kenya.Mitchell1@va.gov.

(3) Combined Synopsis/Solicitation Notice Questions: Questions shall be submitted to the Contracting Officer in writing via e-mail. Oral questions are not acceptable due to the possibility of misunderstanding or misinterpretation. The cut-off date and time for receipt of questions is July 20, 2026, by 5:00 PM EST. Questions received after this date and time may not be answered. Questions shall be answered in a formal amendment to the solicitation so all interested parties can see the answers.

(4) Quote Format: The submission should be clearly indexed and logically assembled in order of the evaluation criteria below. All pages of the quote shall be appropriately numbered and identified by the complete company name, date and solicitation number in the header and/or footer.

Evaluation Process:

Award shall be made to the best value, as determined to be the most beneficial to the

Government. Please read each section below carefully for the submittals and information

required as part of the evaluation. Failure to provide the requested information below shall be

considered non-compliant and your quote could be removed from the evaluation process.

Offeror quotes shall be evaluated under FAR Part 13.106-2(b) -- Evaluation of Quotations or

Offers. Therefore, the Government is not obligated to determine a competitive range, conduct

discussions with all contractors, solicit final revised quotes, and use other techniques associated

with FAR Part 15.

The Government shall award a contract resulting from this solicitation to the responsible offeror

whose offer conforming to the solicitation shall be most advantageous to the Government, price

and other factors considered. The following factors shall be used to evaluate offers:

1. Price (Follow these instructions):

a. Offeror shall complete Price Schedule (pg. 9), with offerors proposed

contract line item prices inserted in appropriate spaces.

2. Past Performance:

a. Offeror shall provide at least one (1) but no more than (3) references of work, similar in scope and size with the requirement detailed in the (Performance Work Statement). References may be checked by the Contracting Officer to ensure your company is capable of performing the Statement of Work. The Government also reserves the right to

obtain information for use in the evaluation of past performance from any and all

sources.

3. Technical: The offeror s quote shall be evaluated to determine if the organization has the

experience and capabilities to provide the requested services IAW the (Performance

Work Statement) in a timely efficient manner.

a. Contractor shall demonstrate their corporate experience and approach to meet all

requirements stated in the (Performance Work Statement).

b. Contractor shall demonstrate that their technicians meet the qualification

standards stated in the (Performance Work Statement).

c. If you are planning to sub-contract some or all of this work, please provide the

name and address(s) of all subcontractor(s) (if applicable) and a description of

their planned subcontracting effort.

SAM: Interested parties shall be registered in System for Award Management (SAM) as

prescribed in FAR Clause 52.232-33. SAM information can be obtained by accessing the internet

at www.sam.gov or by calling 1-866-606-8220. Interested parties not registered in SAM in

sufficient time to meet the VA s requirement will be ineligible to receive a government contract.

This determination will be at the discretion of the Contracting Officer.

VISTA: The VA utilizes VISTA to issue a purchase order and liquidate invoices. Failure to

register in VISTA may result in exclusion from the issuance of a VA contract. This

determination will be at the discretion of the Contracting Officer. Interested parties with no prior

VA contracts can request a Form 10091 at any time.

(x) Please include a completed copy of the provision at 52.212-3, Offeror Representations and

Certifications -- Commercial Items, with your offer via the SAM.gov website or a written copy.

(xi) Clause 52.212-4, Contract Terms and Conditions -- Commercial Items (OCT 2018), applies

to this acquisition in addition to the following addenda s to the clause: 52.204-16 Commercial

and Government Entity Code Maintenance (JUL 2016); 52.219-6 Notice of Total Small Business

Set-Aside; 52.232-40 Providing Accelerated Payments to Small Business Subcontractors (DEC

2013); 852.203-70 Commercial Advertising (MAY 2008); 852.232-72 Electronic Submission of

Payment Requests (NOV 2018)

Subcontracting Commitments - Monitoring and Compliance

This solicitation includes VAAR 852.215-70, Service-Disabled Veteran-Owned and Veteran

Owned Small Business Evaluation Factors, and VAAR 852.215-71, Evaluation Factor

Commitments. Accordingly, any contract resulting from this solicitation will include these

clauses. The contractor is advised in performing contract administration functions, the CO may

use the services of a support contractor(s) to assist in assessing contractor compliance with the

subcontracting commitments incorporated into the

Information Protection and Non-Disclosure and Disclosure of Conflicts of Interest Agreement

to ensure the contractor's business records or other proprietary data reviewed or obtained in the

course of assisting the CO in assessing the contractor for compliance are protected to ensure

information or data is not improperly disclosed or other impropriety occurs. Furthermore, if VA

determines any services the support contractor(s) will perform in assessing compliance are

advisory and assistance services as defined in FAR 2.101, Definitions, the support contractor(s)

must also enter into an agreement with the contractor to protect proprietary information as

required by FAR 9.505-4, Obtaining access to proprietary information, paragraph (b). The

contractor is required to cooperate fully and make available any records as may be required to

enable the CO to assess the contractor compliance with the subcontracting commitments.

(xii) Clause at 52.212-5, Contract Terms and Conditions Required To Implement Statutes Or

Executive Orders -- Commercial Items, applies to this acquisition and in addition to the

following FAR clauses cited, which are also applicable to the acquisition: 52.204-10, 52.209-6,

52.219-6, 52.219-28, 52.222-3, 52.222-21, 52.222-26, 52.222-36, 52.222-50, 52.223-18, 52.232

33, 52.222-41, 52.222-43 (Wage Determination Applicable (White River Junction 2015-4139 Rev 33 posted on beta.sam.gov)

(xiii) All contract requirement(s) and/or terms and conditions are stated above.

(xiv) The Defense Priorities and Allocations System (DPAS) and assigned rating are not

applicable to this requirement.

(xv) RFQ responses are due August 7, 2026, by 5:00 PM EST. RFQ responses must be

submitted via email to: kenya.mitchell1@va.gov. Hand deliveries shall not be accepted.

(xvi) The POC of this solicitation is kenya.mitchell1@va.gov)

STATEMENT OF WORK (SOW)

Fire Door Assembly Survey, Inspection and Repair (FY26-FY31)

Department of Veterans Affairs White River Junction VA Medical Center

Period of Performance:

12 months from date of award with 4 option years.

The survey, initial round of inspections and associated repairs, shall be completed within 3 months of contract award, though not extend beyond the end of the contract award fiscal year. Subsequent inspections and repairs shall be completed not less than annually, based on the completion of the previous year s inspections.

Place of Performance/Place of Delivery

Address:

163 Veterans Drive,

White River Junction, VT

Postal Code:

05009

Country:

UNITED STATES

Project Scope:

The VA Medical Center White River Junction (VAMC WRJ) requires the services of a qualified firm to provide multiple Fire Door Assembly-related services. Required services include:

a campus wide survey of existing fire door assemblies,

annual inspections, and

repair services (as determined during the inspection phase)

VAMC WRJ campus, 215 North Main Street, White River Junction, VT, 05009, is a fully functioning medical center comprised of 39 buildings situated on 64 acres. The buildings are a mix of wood framed, two story residential style structures and multi-floor masonry structures. The campus is walkable and many of the buildings are interconnected. Access is straightforward with VA supervision. Building specific information (building number, usage, number of floors, age) can be found in the attached Master Building List. The goal of the survey portion of this contract is to identify every fire door assembly in each building across campus. The survey will include an in-person walkthrough of each building to determine the quantity and location of each fire door assembly within each individual building. There are approximately 300 fire door assemblies across campus. The results of the fire door survey and associated submittal only apply to the base year of this contract and will be used as the baseline document for the annual inspection process.

The contract shall include three separate pricing components:

Base Year:

Campus wide Fire Door Assembly Survey, which will apply only to base year pricing.

Fire Door Assembly inspection services and reporting.

Estimated repairs: A $7,000.00 contingency for repairs will be included each year.

Plus Four, option years:

Fire Door Assembly annual inspection and reporting.

Estimated repairs.

See table format at the end of this document.

Contract line items:

The contract is based on 300 fire door assemblies across 39 buildings. In addition to the Survey, Inspection and Repair line-item costs, provide a cost per door for:

Cost of an additional door survey and the cost of an individual fire door assembly inspection

In the event that more than 300 fire doors are identified. The additional fire door survey and/or inspection costs can be addressed via modification

In the event that fewer than 300 fire doors are identified, the cost per door will be de-obligated from the base year pricing.

Campus map and Master Building List are attached.

The base year, campus wide survey results will serve as the master list of fire door assemblies for the annual inspection portion of the contract.

Existing Site Conditions: The inspections will take place in occupied healthcare facilities. All activities will be completed in such a way as to minimize impact on staff and patients. Inspection activity will require constant coordination with VA personnel and may require Infection Control measures.

Pre-bid site investigation to ensure accuracy of the proposal is encouraged for this project. The service firm shall be responsible for verifying all existing conditions, quantities and locations that may affect the bid of this project. The person(s) conducting the site investigation are to check in, on the date specified above, with the VAMC WRJ Facilities Management Services department and will be escorted to review the Fire Door locations.

Work shall be completed in conformance with the time schedule requested by the VA Contracting Officer s Representative (COR) or Resident Engineer (RE). The service firm is solely responsible for preparing all necessary regulatory notifications to meet the time schedule.

The service firm shall also be responsible for all damage to people or property that occurred as a result of the service firm s fault or negligence.

The service firm shall also be responsible for all materials delivered to VAMC WRJ and work performed until completion and acceptance of the entire work.

Inspection Guidelines and Submittals: Inspection personnel are expected to follow current NFPA 101 and NFPA 80 guidelines. During the pre-inspection visit, prior to any inspections, submit the proposed Inspection Checklist for COR approval.

Requirements and Tasks:

Fire Door surveys, inspections and repairs are to be performed by a certified technician. Credentials issued by an approved organization, for all survey/inspection personnel, are to be included in the contract bid proposal.

Survey: Using the VAMC WRJ Master Building List in its current Excel format, generate a master list of Fire Doors within each building. The current Excel format is preferred-adding an individual page to the workbook for each building, recording fire door information on each building s page. Each door must have an individual identification: specifying building number, location within each building by floor, additional identification by location within a hallway or clinic adjacency.

The VA will assist with building location nomenclature and drawings as needed.

An accepted, approved master list is required prior to commencement of the inspection portion of this contract.

Inspections: inspect each fire door using accepted industry standard inspection guidelines outlined in the current standards, NFPA 80, Standard for Fire Doors and Other Openings, and NFPA 101, Life Safety Code.

Log the individual fire door inspection results onto the pre-approved inspection document-see submittals requirements below.

Identify doors needing repairs- see submittals requirements below.

The VA reserves the right to prioritize and execute suggested repairs.

Submittals:

Pre-inspection:

Credentials of all inspectors and repair personnel.

Fire Door Inspection checklist boiler plate document.

Experience and References, commercial and healthcare environment experience required.

Post Inspection:

Campus wide Fire Door Survey-submit in Excel format, building on the VMAC WRJ Master Building List.

Completed Fire Door Inspection checklists-using the approved boiler plate Fire Door Assembly inspection form, in PDF format, compiled by building into a single master document

Separate PDF document identifying each fire door in need of repair, including the repair requirements

Work Schedule

Normal working hours are Monday through Friday, from 7:30 AM to 4:30 PM. Excluding federal holidays.

Work Performed After Hours: Work may be performed after hours: coordinate these efforts with the COR with a minimum 48-hour notice.

In order to maintain schedule, work performed over the weekend may be allowed. Contractor to coordinate these efforts with VA COR with a minimum 48-hour notice.

Privacy Statement

Information Security: The C&A requirements do not apply; a Security Accreditation Package is not required. Incidental exposure to protected health information may occur from accessing the work site. Staff will follow all Privacy & Security policies and procedures.

Record Management

The following standard items relate to records generated in executing the contract and should be included in a typical procurement contract:

1. Citations to pertinent laws, codes, and regulations such as 44 U.S.C chapters 21, 29, 31 and 33; Freedom of Information Act (5 U.S.C. 552); Privacy Act (5 U.S.C. 552a); 36 CFR Part 1222 and Part 1228.

2. The service firm shall treat all deliverables under the contract as the property of the U.S. Government for which the Government Agency shall have unlimited rights to use, dispose of, or disclose such data contained therein as it determines to be in the public interest.

3. The service firm shall not create or maintain any records that are not specifically tied to or authorized by the contract using Government IT equipment and/or Government records.

4. The service firm shall not retain, use, sell, or disseminate copies of any deliverable that contains information covered by the Privacy Act of 1974 or which is generally protected by the Freedom of Information Act.

5. The service firm shall not create or maintain any records containing any Government Agency records that are not specifically tied to or authorized by the contract.

6. The Government Agency owns the rights to all data/records produced as part of this contract.

7. The Government Agency owns the rights to all electronic information (electronic data, electronic information systems, electronic databases, etc.) and all supporting documentation created as part of this contract. The service firm must deliver sufficient technical documentation with all deliverables to permit the agency to use the data.

8. The service firm agrees to comply with Federal and Agency records management policies, including those policies associated with the safeguarding of records covered by the Privacy Act of 1974. These policies include the preservation of all records created or received regardless of format [paper, electronic, etc.] or mode of transmission [e-mail, fax, etc.] or state of completion [draft, final, etc.].

The service firm (and any sub-contractor) is required to abide by Government and Agency guidance for protecting sensitive and proprietary information.

Payment processed through Tungsten/IPPS. Invoices to be submitted in draft form digitally to the COR for review prior to submission in Tungsten/IPPS. Invoicing for services rendered.

The full text of FAR provisions or clauses may be accessed electronically at https://www.acquisition.gov/browse/index/far.

Supplies/Services

ITEM NUMBER

DESCRIPTION OF SUPPLIES/SERVICES

QUANTITY

UNIT

UNIT PRICE

AMOUNT

0001

Fire Door Survey Services in accordance with the SOW

Period: Base

1.00

JB

__________________

__________________

0002

Fire Door Inspection Services in accordance with the SOW

Period: Base

1.00

EA

__________________

__________________

0003

Fire Door Repair Services in accordance with the SOW

Period: Base

1.00

YR

$7,000.00

$7,000.00

1001

Fire Door Inspection Services in accordance with the SOW

Period: OY 1

1.00

EA

__________________

__________________

1002

Fire Door Repair Services in accordance with the SOW

Period: OY 1

1.00

YR

$7,000.00

$7,000.00

2001

Fire Door Inspection Services in accordance with the SOW

Period: OY2

1.00

EA

__________________

__________________

2002

Fire Door Repair Services in accordance with the SOW

Period: OY 2

1.00

YR

$7,000.00

$7,000.00

3001

Fire Door Inspection Services in accordance with the SOW

Period: OY 3

1.00

EA

__________________

__________________

3002

Fire Door Repair Services in accordance with the SOW

Period: OY 3

1.00

YR

$7,000.00

$7,000.00

4001

Fire Door Inspection Services in accordance with the SOW

Period: OY 4

1.00

EA

__________________

__________________

4002

Fire Door Repair Services in accordance with the SOW

Period: OY 4

1.00

YR

$7,000.00

$7,000.00

TOTAL

__________________

__________________

Update #2 ·

The purpose of Amendment 0001 is to extend the quote due date to 3 August 2026 at 5:00 PM EST.

Update #1 ·

Combined Synopsis-Solicitation for Commercial Products and Commercial Services

Effective Date: 04/18/2025

Revision: 02

Description

(i) This is a combined synopsis/solicitation for commercial items prepared in accordance with

the format in Subpart 12.6, as supplemented with additional information included in this notice.

This announcement constitutes the only solicitation; proposals are being requested and a written

solicitation will not be issued.

(ii) The solicitation number is 36C24126Q0632 and the solicitation is issued as a request for

quotation (RFQ).

(iii) A statement that the solicitation document and incorporated provisions and clauses are those

in effect through Federal Acquisition Circular 2026-01.

(iv) This requirement is being issued as a SDVOSB set-aside. The associated NAICS

541350 and small business size standard is $11.5 million.

(v) The Government intends to award a firm-fixed price award for Fire Door Assembly Survey, Inspection and Repair Services at White River Junctions VAMC. Please see the attached Performance Work Statement for full requirement details. Please complete the Price Schedule below and submit with the quote submission.

(vi) The Contractor shall provide all resources necessary to provide Fire Door Assembly Survey, Inspection and Repair Services IAW the attached (Performance Work Statement). Please see the attached PWS for full requirement details.

(vii) The Place of Performance is White River Junction VAMC as described per the (Performance Work Statement).

(viii) Provision at 52.212-1, Instructions to Offerors -- Commercial, applies to this acquisition in

addition to the following addenda s to the provision: 52.252-1 Solicitation Provisions

Incorporated by Reference (FEB 1998); 52.204-7 System for Award Management (OCT 2018);

52.204-16 Commercial and Government Entity Code Reporting (JUL 2016); 52.217-5

Evaluation of Options (JUL 1990); 852.252-70 Solicitation Provisions or Clauses Incorporated

by Reference (JAN 2008)

(ix) Provision at 52.212-2, Evaluation -- Commercial Items, applies to this requirement.:

Site Visit: July 16, 2026 @ 10:00 AM

Address: 163 Veterans Drive, BLDG 37

White River Junction, VT

Postal Code: 05009

POC: James Kirkpatrick

Submission of Quotes:

(1) Quotes shall be received on or before the date and time specified in Section (xv) of this

solicitation. Note: Offers received after the due date and time shall not be considered.

(2) Offerors shall submit their quotes electronically via email to Kenya.Mitchell1@va.gov.

(3) Combined Synopsis/Solicitation Notice Questions: Questions shall be submitted to the Contracting Officer in writing via e-mail. Oral questions are not acceptable due to the possibility of misunderstanding or misinterpretation. The cut-off date and time for receipt of questions is July 20, 2026, by 5:00 PM EST. Questions received after this date and time may not be answered. Questions shall be answered in a formal amendment to the solicitation so all interested parties can see the answers.

(4) Quote Format: The submission should be clearly indexed and logically assembled in order of the evaluation criteria below. All pages of the quote shall be appropriately numbered and identified by the complete company name, date and solicitation number in the header and/or footer.

Evaluation Process:

Award shall be made to the best value, as determined to be the most beneficial to the

Government. Please read each section below carefully for the submittals and information

required as part of the evaluation. Failure to provide the requested information below shall be

considered non-compliant and your quote could be removed from the evaluation process.

Offeror quotes shall be evaluated under FAR Part 13.106-2(b) -- Evaluation of Quotations or

Offers. Therefore, the Government is not obligated to determine a competitive range, conduct

discussions with all contractors, solicit final revised quotes, and use other techniques associated

with FAR Part 15.

The Government shall award a contract resulting from this solicitation to the responsible offeror

whose offer conforming to the solicitation shall be most advantageous to the Government, price

and other factors considered. The following factors shall be used to evaluate offers:

1. Price (Follow these instructions):

a. Offeror shall complete Attachment 1 - Price Schedule, with offerors proposed

contract line item prices inserted in appropriate spaces.

2. Past Performance:

a. Offeror shall utilize Attachment 2 Past Performance Worksheet to provide at

least one (1) but no more than (3) references of work, similar in scope and size

with the requirement detailed in the (Performance Work Statement). References

may be checked by the Contracting Officer to ensure your company is capable of

performing the Statement of Work. The Government also reserves the right to

obtain information for use in the evaluation of past performance from any and all

sources.

3. Technical: The offeror s quote shall be evaluated to determine if the organization has the

experience and capabilities to provide the requested services IAW the (Performance

Work Statement) in a timely efficient manner.

a. Contractor shall demonstrate their corporate experience and approach to meet all

requirements stated in the (Performance Work Statement).

b. Contractor shall demonstrate that their technicians meet the qualification

standards stated in the (Performance Work Statement).

c. If you are planning to sub-contract some or all of this work, please provide the

name and address(s) of all subcontractor(s) (if applicable) and a description of

their planned subcontracting effort.

SAM: Interested parties shall be registered in System for Award Management (SAM) as

prescribed in FAR Clause 52.232-33. SAM information can be obtained by accessing the internet

at www.sam.gov or by calling 1-866-606-8220. Interested parties not registered in SAM in

sufficient time to meet the VA s requirement will be ineligible to receive a government contract.

This determination will be at the discretion of the Contracting Officer.

VISTA: The VA utilizes VISTA to issue a purchase order and liquidate invoices. Failure to

register in VISTA may result in exclusion from the issuance of a VA contract. This

determination will be at the discretion of the Contracting Officer. Interested parties with no prior

VA contracts can request a Form 10091 at any time.

(x) Please include a completed copy of the provision at 52.212-3, Offeror Representations and

Certifications -- Commercial Items, with your offer via the SAM.gov website or a written copy.

(xi) Clause 52.212-4, Contract Terms and Conditions -- Commercial Items (OCT 2018), applies

to this acquisition in addition to the following addenda s to the clause: 52.204-16 Commercial

and Government Entity Code Maintenance (JUL 2016); 52.219-6 Notice of Total Small Business

Set-Aside; 52.232-40 Providing Accelerated Payments to Small Business Subcontractors (DEC

2013); 852.203-70 Commercial Advertising (MAY 2008); 852.232-72 Electronic Submission of

Payment Requests (NOV 2018)

Subcontracting Commitments - Monitoring and Compliance

This solicitation includes VAAR 852.215-70, Service-Disabled Veteran-Owned and Veteran

Owned Small Business Evaluation Factors, and VAAR 852.215-71, Evaluation Factor

Commitments. Accordingly, any contract resulting from this solicitation will include these

clauses. The contractor is advised in performing contract administration functions, the CO may

use the services of a support contractor(s) to assist in assessing contractor compliance with the

subcontracting commitments incorporated into the

Information Protection and Non-Disclosure and Disclosure of Conflicts of Interest Agreement

to ensure the contractor's business records or other proprietary data reviewed or obtained in the

course of assisting the CO in assessing the contractor for compliance are protected to ensure

information or data is not improperly disclosed or other impropriety occurs. Furthermore, if VA

determines any services the support contractor(s) will perform in assessing compliance are

advisory and assistance services as defined in FAR 2.101, Definitions, the support contractor(s)

must also enter into an agreement with the contractor to protect proprietary information as

required by FAR 9.505-4, Obtaining access to proprietary information, paragraph (b). The

contractor is required to cooperate fully and make available any records as may be required to

enable the CO to assess the contractor compliance with the subcontracting commitments.

(xii) Clause at 52.212-5, Contract Terms and Conditions Required To Implement Statutes Or

Executive Orders -- Commercial Items, applies to this acquisition and in addition to the

following FAR clauses cited, which are also applicable to the acquisition: 52.204-10, 52.209-6,

52.219-6, 52.219-28, 52.222-3, 52.222-21, 52.222-26, 52.222-36, 52.222-50, 52.223-18, 52.232

33, 52.222-41, 52.222-43 (Wage Determination Applicable (White River Junction 2015-4139 Rev 33 posted on beta.sam.gov)

(xiii) All contract requirement(s) and/or terms and conditions are stated above.

(xiv) The Defense Priorities and Allocations System (DPAS) and assigned rating are not

applicable to this requirement.

(xv) RFQ responses are due July 27, 2026, by 5:00 PM EST. RFQ responses must be

submitted via email to: kenya.mitchell1@va.gov. Hand deliveries shall not be accepted.

(xvi) The POC of this solicitation is kenya.mitchell1@va.gov)

STATEMENT OF WORK (SOW)

Fire Door Assembly Survey, Inspection and Repair (FY26-FY31)

Department of Veterans Affairs White River Junction VA Medical Center

Period of Performance:

12 months from date of award with 4 option years.

The survey, initial round of inspections and associated repairs, shall be completed within 3 months of contract award, though not extend beyond the end of the contract award fiscal year. Subsequent inspections and repairs shall be completed not less than annually, based on the completion of the previous year s inspections.

Place of Performance/Place of Delivery

Address:

163 Veterans Drive,

White River Junction, VT

Postal Code:

05009

Country:

UNITED STATES

Project Scope:

The VA Medical Center White River Junction (VAMC WRJ) requires the services of a qualified firm to provide multiple Fire Door Assembly-related services. Required services include:

a campus wide survey of existing fire door assemblies,

annual inspections, and

repair services (as determined during the inspection phase)

VAMC WRJ campus, 215 North Main Street, White River Junction, VT, 05009, is a fully functioning medical center comprised of 39 buildings situated on 64 acres. The buildings are a mix of wood framed, two story residential style structures and multi-floor masonry structures. The campus is walkable and many of the buildings are interconnected. Access is straightforward with VA supervision. Building specific information (building number, usage, number of floors, age) can be found in the attached Master Building List. The goal of the survey portion of this contract is to identify every fire door assembly in each building across campus. The survey will include an in-person walkthrough of each building to determine the quantity and location of each fire door assembly within each individual building. There are approximately 300 fire door assemblies across campus. The results of the fire door survey and associated submittal only apply to the base year of this contract and will be used as the baseline document for the annual inspection process.

The contract shall include three separate pricing components:

Base Year:

Campus wide Fire Door Assembly Survey, which will apply only to base year pricing.

Fire Door Assembly inspection services and reporting.

Estimated repairs: A $7,000.00 contingency for repairs will be included each year.

Plus Four, option years:

Fire Door Assembly annual inspection and reporting.

Estimated repairs.

See table format at the end of this document.

Contract line items:

The contract is based on 300 fire door assemblies across 39 buildings. In addition to the Survey, Inspection and Repair line-item costs, provide a cost per door for:

Cost of an additional door survey and the cost of an individual fire door assembly inspection

In the event that more than 300 fire doors are identified. The additional fire door survey and/or inspection costs can be addressed via modification

In the event that fewer than 300 fire doors are identified, the cost per door will be de-obligated from the base year pricing.

Campus map and Master Building List are attached.

The base year, campus wide survey results will serve as the master list of fire door assemblies for the annual inspection portion of the contract.

Existing Site Conditions: The inspections will take place in occupied healthcare facilities. All activities will be completed in such a way as to minimize impact on staff and patients. Inspection activity will require constant coordination with VA personnel and may require Infection Control measures.

Pre-bid site investigation to ensure accuracy of the proposal is encouraged for this project. The service firm shall be responsible for verifying all existing conditions, quantities and locations that may affect the bid of this project. The person(s) conducting the site investigation are to check in, on the date specified above, with the VAMC WRJ Facilities Management Services department and will be escorted to review the Fire Door locations.

Work shall be completed in conformance with the time schedule requested by the VA Contracting Officer s Representative (COR) or Resident Engineer (RE). The service firm is solely responsible for preparing all necessary regulatory notifications to meet the time schedule.

The service firm shall also be responsible for all damage to people or property that occurred as a result of the service firm s fault or negligence.

The service firm shall also be responsible for all materials delivered to VAMC WRJ and work performed until completion and acceptance of the entire work.

Inspection Guidelines and Submittals: Inspection personnel are expected to follow current NFPA 101 and NFPA 80 guidelines. During the pre-inspection visit, prior to any inspections, submit the proposed Inspection Checklist for COR approval.

Requirements and Tasks:

Fire Door surveys, inspections and repairs are to be performed by a certified technician. Credentials issued by an approved organization, for all survey/inspection personnel, are to be included in the contract bid proposal.

Survey: Using the VAMC WRJ Master Building List in its current Excel format, generate a master list of Fire Doors within each building. The current Excel format is preferred-adding an individual page to the workbook for each building, recording fire door information on each building s page. Each door must have an individual identification: specifying building number, location within each building by floor, additional identification by location within a hallway or clinic adjacency.

The VA will assist with building location nomenclature and drawings as needed.

An accepted, approved master list is required prior to commencement of the inspection portion of this contract.

Inspections: inspect each fire door using accepted industry standard inspection guidelines outlined in the current standards, NFPA 80, Standard for Fire Doors and Other Openings, and NFPA 101, Life Safety Code.

Log the individual fire door inspection results onto the pre-approved inspection document-see submittals requirements below.

Identify doors needing repairs- see submittals requirements below.

The VA reserves the right to prioritize and execute suggested repairs.

Submittals:

Pre-inspection:

Credentials of all inspectors and repair personnel.

Fire Door Inspection checklist boiler plate document.

Experience and References, commercial and healthcare environment experience required.

Post Inspection:

Campus wide Fire Door Survey-submit in Excel format, building on the VMAC WRJ Master Building List.

Completed Fire Door Inspection checklists-using the approved boiler plate Fire Door Assembly inspection form, in PDF format, compiled by building into a single master document

Separate PDF document identifying each fire door in need of repair, including the repair requirements

Work Schedule

Normal working hours are Monday through Friday, from 7:30 AM to 4:30 PM. Excluding federal holidays.

Work Performed After Hours: Work may be performed after hours: coordinate these efforts with the COR with a minimum 48-hour notice.

In order to maintain schedule, work performed over the weekend may be allowed. Contractor to coordinate these efforts with VA COR with a minimum 48-hour notice.

Privacy Statement

Information Security: The C&A requirements do not apply; a Security Accreditation Package is not required. Incidental exposure to protected health information may occur from accessing the work site. Staff will follow all Privacy & Security policies and procedures.

Record Management

The following standard items relate to records generated in executing the contract and should be included in a typical procurement contract:

1. Citations to pertinent laws, codes, and regulations such as 44 U.S.C chapters 21, 29, 31 and 33; Freedom of Information Act (5 U.S.C. 552); Privacy Act (5 U.S.C. 552a); 36 CFR Part 1222 and Part 1228.

2. The service firm shall treat all deliverables under the contract as the property of the U.S. Government for which the Government Agency shall have unlimited rights to use, dispose of, or disclose such data contained therein as it determines to be in the public interest.

3. The service firm shall not create or maintain any records that are not specifically tied to or authorized by the contract using Government IT equipment and/or Government records.

4. The service firm shall not retain, use, sell, or disseminate copies of any deliverable that contains information covered by the Privacy Act of 1974 or which is generally protected by the Freedom of Information Act.

5. The service firm shall not create or maintain any records containing any Government Agency records that are not specifically tied to or authorized by the contract.

6. The Government Agency owns the rights to all data/records produced as part of this contract.

7. The Government Agency owns the rights to all electronic information (electronic data, electronic information systems, electronic databases, etc.) and all supporting documentation created as part of this contract. The service firm must deliver sufficient technical documentation with all deliverables to permit the agency to use the data.

8. The service firm agrees to comply with Federal and Agency records management policies, including those policies associated with the safeguarding of records covered by the Privacy Act of 1974. These policies include the preservation of all records created or received regardless of format [paper, electronic, etc.] or mode of transmission [e-mail, fax, etc.] or state of completion [draft, final, etc.].

The service firm (and any sub-contractor) is required to abide by Government and Agency guidance for protecting sensitive and proprietary information.

Payment processed through Tungsten/IPPS. Invoices to be submitted in draft form digitally to the COR for review prior to submission in Tungsten/IPPS. Invoicing for services rendered.

The full text of FAR provisions or clauses may be accessed electronically at https://www.acquisition.gov/browse/index/far.

Supplies/Services

ITEM NUMBER

DESCRIPTION OF SUPPLIES/SERVICES

QUANTITY

UNIT

UNIT PRICE

AMOUNT

0001

Fire Door Survey Services in accordance with the SOW

Period: Base

1.00

JB

__________________

__________________

0002

Fire Door Inspection Services in accordance with the SOW

Period: Base

1.00

EA

__________________

__________________

0003

Fire Door Repair Services in accordance with the SOW

Period: Base

1.00

YR

$7,000.00

$7,000.00

1001

Fire Door Inspection Services in accordance with the SOW

Period: OY 1

1.00

EA

__________________

__________________

1002

Fire Door Repair Services in accordance with the SOW

Period: OY 1

1.00

YR

$7,000.00

$7,000.00

2001

Fire Door Inspection Services in accordance with the SOW

Period: OY2

1.00

EA

__________________

__________________

2002

Fire Door Repair Services in accordance with the SOW

Period: OY 2

1.00

YR

$7,000.00

$7,000.00

3001

Fire Door Inspection Services in accordance with the SOW

Period: OY 3

1.00

EA

__________________

__________________

3002

Fire Door Repair Services in accordance with the SOW

Period: OY 3

1.00

YR

$7,000.00

$7,000.00

4001

Fire Door Inspection Services in accordance with the SOW

Period: OY 4

1.00

EA

__________________

__________________

4002

Fire Door Repair Services in accordance with the SOW

Period: OY 4

1.00

YR

$7,000.00

$7,000.00

TOTAL

__________________

__________________

Files

Show all 12

Similar open opportunities

Opportunity Agency Set-aside Responses due
H112--Annual/Sem-i annual fire smoke inspections and auto door services l EKH Kansas 66048, United States · NAICS 541350 Veterans Integrated Service Network 15 Total Small Business
CANCELLED - Annual Inventory and Inspection of Fire and Smoke Doors - CANCELLED Dallas, Texas 75216, United States · NAICS 541350 Veterans Integrated Service Network 17 Service-Disabled Veteran-Owned Small Business
CTX Life Safety Assessment and Fire Damper Inspection Temple, Texas 76504, United States · NAICS 561621 Veterans Integrated Service Network 17 Service-Disabled Veteran-Owned Small Business
N099--JLM Roll Up Door Replacement Eugene J. Towbin Healthcare Center Central Arkansas Veterans Healthcare System North Little Rock AR 72114 · NAICS 238290 Veterans Integrated Service Network 16 Service-Disabled Veteran-Owned Small Business
Fire Door Inspection, Assessment, and Maintenance at the Albuquerque Area IHS Healthcare Facilities Albuquerque, New Mexico 87110, United States · NAICS 561210 Indian Health Service Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors