Electrical Vault 11 Transformer and Switchgear Replacement, ACRF, NIH Bethesda, MD

Award Notice Posted

Solicitation number
NIHOF2015030
Agency
Awarded
to M.c. Dean, Inc.
Set-aside
No set-aside

Opportunity facts

Contract number
HHSN292201500010C Federal contract award
PSC
Not on record
Place of performance
National Institutes of Health Bethesda Campus - Building 10 9000 Rockville Pike Bethesda, Maryland 20892, United States

Notice details come from SAM.gov. Updated .

Notice text

8 versions

Update #8 · Latest ·

*Please see AMENDMENT #00001 -- revisions are noted in yellow highlight.

*Please see AMENDMENT #00002 -- add Drawing Security Notification. Agreement.

*Please see AMENDMENT #00003 -- add site visit Q&As.

*Please see AMENDMENT #00004 -- additional site visit.

*Please see AMENDMENT #00005 -- post RFIs.

*Please see AMENDMENT #00006 -- post additional RFIs, SF-1442, and current HHS Small Business Subcontracting Goals.

*Please see AMENDMENT #00007 -- post SF-1442.

*Please see AMENDMENT #00008 -- to correct 13.b. on SF-1442.

Update #7 ·

*Please see AMENDMENT #00001 -- revisions are noted in yellow highlight.

*Please see AMENDMENT #00002 -- add Drawing Security Notification. Agreement.

*Please see AMENDMENT #00003 -- add site visit Q&As.

*Please see AMENDMENT #00004 -- additional site visit.

*Please see AMENDMENT #00005 -- post RFIs.

*Please see AMENDMENT #00006 -- post additional RFIs, SF-1442, and current HHS Small Business Subcontracting Goals.

*Please see AMENDMENT #00007 -- post SF-1442.

Update #6 ·

*Please see AMENDMENT #00001 -- revisions are noted in yellow highlight.

*Please see AMENDMENT #00002 -- add Drawing Security Notification. Agreement.

*Please see AMENDMENT #00003 -- add site visit Q&As.

*Please see AMENDMENT #00004 -- additional site visit.

*Please see AMENDMENT #00005 -- post RFIs.

*Please see AMENDMENT #00006 -- post additional RFIs, SF-1442, and current HHS Small Business Subcontracting Goals.

Update #5 ·

*Please see AMENDMENT #00001 -- revisions are noted in yellow highlight.

*Please see AMENDMENT #00002 -- add Drawing Security Notification Agreement.

*Please see AMENDMENT #00003 -- add site visit Q&As.

*Please see AMENDMENT #00004 -- additional site visit.

*Please see AMENDMENT #00005 -- post RFIs.

Update #4 ·

*Please see AMENDMENT #00001 -- revisions are noted in yellow highlight.

*Please see AMENDMENT #00002 -- add Drawing Security Notification Agreement.

*Please see AMENDMENT #00003 -- add site visit Q&As.

*Please see AMENDMENT #00004 -- additional site visit.

Update #3 ·

RFP #NIHOF2015030:
The National Institutes of Health (NIH), Office of Research Facilities (ORF), plans to enter into a contract with a qualified contractor capable of performing heavy electrical/structural construction services necessary in replacing four 13,800 volt transformers and associated switchgear on the 14th floor of the Ambulatory Care Research Facility (ACRF) tower in electrical Vault 11.  


This project is a major construction/facilities capital investment.  Work will be performed in Building 10's ACRF Tower, located on the NIH Main Campus, Bethesda, Maryland.



CONTRACT INFORMATION:
The contract will be a firm-fixed price, single-award contract.  Total potential contract performance period shall be 780 calendar days from Notice to Proceed.  The contract value is $4-8M.  The project will be advertised in FedBizOpps under a Full and Open competition acquisition process resulting in a Best Value award.


PROJECT INFORMATION:
The NIH is seeking to obtain the services of a highly qualified credentialed contractor with the capability and experience to perform complex electrical infrastructure work involving heavy structural erection over energized 13,800 volt transformers and associated feeders, within an occupied Healthcare or Research facility. The work and associated deliverables to be performed under the contract include, but are not limited to:


Procurement, fabrication, field assembly, installation, testing and commissioning of three (replacement) 2000 KVA, 13.8 KV-480 volt spot network normal power dry type transformers, one (upgraded from 500KVA) 1500 KVA, 13.8 KV-480 emergency power dry type transformer, 480 volt switchgear, interconnecting 480 Volt bus ducts, incoming 15 KV cables from ACRF Vault 10, necessary cable terminations, three 15 KV Fused Load Break Disconnect Switches for normal power feeders 60, 70, 80 and one 15 KV Fused Load break Disconnect Switch for emergency power feeder 85L1(old W10). In addition to transformers and switchgear Vault 11 will be cooled by three (3) new 12-ton vertical floor mounted air conditioning units.


The 13,800 volt feeders #60, #70 & #80 emanating from Vault 10 serve the three existing spot network transformers while Feeder #W10, also emanating from Vault 10, serves the existing 500 KVA emergency transformer. These existing feeders, bus-ways between each transformer, overhead conduit for the switchgear and the switchgear itself will be replaced by this project and are all below the line of the proposed new mezzanine platform that will house the new transformers.


The upgraded emergency power transformer will provide the future capability of adding additional equipment such as the Air Handling Units that supply air to the ambulatory clinics and research laboratories in the ACRF. Additionally the project requires the removal of life safety equipment power for the Clinical Research Center (CRC) to be re-fed from the CRC Vault AB.


This change will mitigate any interruption or disruption that might occur with shutdowns during construction in the vault that could impact the hospital (CRC).


Included in the project will be redundant power sources for: 1) the radio communications supporting NIH fire and police; 2) re-circuiting of stairwells #15 and #16 lighting and pressurization fans in the stairwells; and 3) moving the redundant emergency power source for Pharmacy exhaust fans on ACRF roof to Vault-10.


The first phase of the work will involve the removal of some minor distribution feeders that are in the way of the new transformer platform and the removal of the failed out of service network transformer #80.


After installation of the structural work for the mezzanine platform which encompasses the entire footprint of Vault 11, the sequential removal of each transformer will be accomplished and new dry type transformers assembled, installed, and energized on the new mezzanine platform. Along with each transformer each new section of the electrical switchgear will be installed and connected to the new transformer and distribution feeders to allow uninterrupted power service to the building. Once complete, the old switchgear will be disconnected and removed.


A carefully orchestrated, phased transition shall be required for two distinct equipment block movements; the transition from liquid to dry-type transformers making way for the new switchgear, and the subsequent transition from the existing switchgear to the new. The replacement project must be phased such that two transformers remain in service at all times.


The Statement of Work contains the reports/deliverables required under this solicitation including, but not limited to Monthly Reports, Schedules, Safety and Health Plan, Quality Control Plan, Warranties and Owner's Manuals.


MINIMUM REQUIREMENTS:
Prior to commencing with the selection criteria evaluation, each offeror will be evaluated for compliance with the following minimum qualifications/requirements:


 Mandatory Qualification Criteria 1: Bonding
Mandatory Qualification Criteria 2: Safety Program Pre-Qualification
Mandatory Qualification Criteria 3: Ability to Perform Asbestos/Hazardous Material Removal
Mandatory Qualification Criteria 4: Joint Ventures (If Applicable)


 SELECTION CRITERIA:
For those Offerors meeting the minimum requirements, the Offeror shall receive a technical evaluation based on the following criteria:


FACTOR A: Offeror's Past Performance
FACTOR B: Offeror's Corporate Experience
FACTOR C: Experience of Key Personnel
FACTOR D: Offeror's Management Plan
FACTOR A will be evaluated for performance risk and adjectively rated; FACTOR B through FACTOR D will be adjectively rated. FACTOR B is most important; FACTORs C and D are equally important and individually less important than FACTOR B.


Although technical qualification factors are of paramount consideration in the award of the contract, cost/price is also important to the overall contract award decision. All evaluation factors other than cost or price, when combined, are significantly more important than cost. The Government will award the responsible Offeror whose proposal in the Government's estimation provides the greatest overall benefit in response to the requirement.


Cost/Price Significance.  A trade-off process between the technical merits and the proposed price will be considered for meeting the requirements and obtaining the most economical price to the Government. Price evaluation will be based on Section B - Supplies or Services and Prices/Costs of the proposal. Price will be a factor in the award decision but will be less important than technical.  Technical will be significantly more important than price.


Past Performance.  Past performance for risk is an evaluation element.


Small Business Subcontracting and Small Disadvantaged Business (SDB) Participation Plans.  The Offeror's approach in meeting/exceeding the DHHS goals for Small Business Subcontracting and Small Disadvantaged Business Participation Plans will be required. The price review will score the Offeror's stated Small Business Subcontracting goals verses the contract minimums. Additionally, the Offeror's actual participation in achieving previously stated participation goals will be evaluated. The Plans will also be reviewed by the NIH Small Business Office and the HHS PCR.


FULL SOLICIATION:
For full details, please see RFP #NIHOF2015030 - Date 12-15-2014 and supplemental attachments.


Note: One or more of the items under this acquisition is subject to the World Trade Organization Government Procurement Agreement and Free Trade Agreements.

*Please see AMENDMENT #00001 -- revisions are noted in yellow highlight.

*Please see AMENDMENT #00001 -- add Drawing Security Notification Agreement.

*Please see AMENDMENT #00003 -- add site visit Q&As.

Update #2 ·

*Please see AMENDMENT #00001 -- revisions are noted in yellow highlight.

Update #1 ·

RFP #NIHOF2015030:
The National Institutes of Health (NIH), Office of Research Facilities (ORF), plans to enter into a contract with a qualified contractor capable of performing heavy electrical/structural construction services necessary in replacing four 13,800 volt transformers and associated switchgear on the 14th floor of the Ambulatory Care Research Facility (ACRF) tower in electrical Vault 11.  


This project is a major construction/facilities capital investment.  Work will be performed in Building 10's ACRF Tower, located on the NIH Main Campus, Bethesda, Maryland.



CONTRACT INFORMATION:
The contract will be a firm-fixed price, single-award contract.  Total potential contract performance period shall be 780 calendar days from Notice to Proceed.  The contract value is $4-8M.  The project will be advertised in FedBizOpps under a Full and Open competition acquisition process resulting in a Best Value award.


PROJECT INFORMATION:
The NIH is seeking to obtain the services of a highly qualified credentialed contractor with the capability and experience to perform complex electrical infrastructure work involving heavy structural erection over energized 13,800 volt transformers and associated feeders, within an occupied Healthcare or Research facility. The work and associated deliverables to be performed under the contract include, but are not limited to:


Procurement, fabrication, field assembly, installation, testing and commissioning of three (replacement) 2000 KVA, 13.8 KV-480 volt spot network normal power dry type transformers, one (upgraded from 500KVA) 1500 KVA, 13.8 KV-480 emergency power dry type transformer, 480 volt switchgear, interconnecting 480 Volt bus ducts, incoming 15 KV cables from ACRF Vault 10, necessary cable terminations, three 15 KV Fused Load Break Disconnect Switches for normal power feeders 60, 70, 80 and one 15 KV Fused Load break Disconnect Switch for emergency power feeder 85L1(old W10). In addition to transformers and switchgear Vault 11 will be cooled by three (3) new 12-ton vertical floor mounted air conditioning units.


The 13,800 volt feeders #60, #70 & #80 emanating from Vault 10 serve the three existing spot network transformers while Feeder #W10, also emanating from Vault 10, serves the existing 500 KVA emergency transformer. These existing feeders, bus-ways between each transformer, overhead conduit for the switchgear and the switchgear itself will be replaced by this project and are all below the line of the proposed new mezzanine platform that will house the new transformers.


The upgraded emergency power transformer will provide the future capability of adding additional equipment such as the Air Handling Units that supply air to the ambulatory clinics and research laboratories in the ACRF. Additionally the project requires the removal of life safety equipment power for the Clinical Research Center (CRC) to be re-fed from the CRC Vault AB.


This change will mitigate any interruption or disruption that might occur with shutdowns during construction in the vault that could impact the hospital (CRC).


Included in the project will be redundant power sources for: 1) the radio communications supporting NIH fire and police; 2) re-circuiting of stairwells #15 and #16 lighting and pressurization fans in the stairwells; and 3) moving the redundant emergency power source for Pharmacy exhaust fans on ACRF roof to Vault-10.


The first phase of the work will involve the removal of some minor distribution feeders that are in the way of the new transformer platform and the removal of the failed out of service network transformer #80.


After installation of the structural work for the mezzanine platform which encompasses the entire footprint of Vault 11, the sequential removal of each transformer will be accomplished and new dry type transformers assembled, installed, and energized on the new mezzanine platform. Along with each transformer each new section of the electrical switchgear will be installed and connected to the new transformer and distribution feeders to allow uninterrupted power service to the building. Once complete, the old switchgear will be disconnected and removed.


A carefully orchestrated, phased transition shall be required for two distinct equipment block movements; the transition from liquid to dry-type transformers making way for the new switchgear, and the subsequent transition from the existing switchgear to the new. The replacement project must be phased such that two transformers remain in service at all times.


The Statement of Work contains the reports/deliverables required under this solicitation including, but not limited to Monthly Reports, Schedules, Safety and Health Plan, Quality Control Plan, Warranties and Owner's Manuals.


MINIMUM REQUIREMENTS:
Prior to commencing with the selection criteria evaluation, each offeror will be evaluated for compliance with the following minimum qualifications/requirements:


 


Mandatory Qualification Criteria 1: Bonding
Mandatory Qualification Criteria 2: Safety Program Pre-Qualification
Mandatory Qualification Criteria 3: Ability to Perform Asbestos/Hazardous Material Removal
Mandatory Qualification Criteria 4: Joint Ventures (If Applicable)


 


SELECTION CRITERIA:
For those Offerors meeting the minimum requirements, the Offeror shall receive a technical evaluation based on the following criteria:


 


FACTOR A: Offeror's Past Performance
FACTOR B: Offeror's Corporate Experience
FACTOR C: Experience of Key Personnel
FACTOR D: Offeror's Management Plan
FACTOR A will be evaluated for performance risk and adjectively rated; FACTOR B through FACTOR D will be adjectively rated. FACTOR B is most important; FACTORs C and D are equally important and individually less important than FACTOR B.


 


Although technical qualification factors are of paramount consideration in the award of the contract, cost/price is also important to the overall contract award decision. All evaluation factors other than cost or price, when combined, are significantly more important than cost. The Government will award the responsible Offeror whose proposal in the Government's estimation provides the greatest overall benefit in response to the requirement.


 


Cost/Price Significance.  A trade-off process between the technical merits and the proposed price will be considered for meeting the requirements and obtaining the most economical price to the Government. Price evaluation will be based on Section B - Supplies or Services and Prices/Costs of the proposal. Price will be a factor in the award decision but will be less important than technical.  Technical will be significantly more important than price.


 


Past Performance.  Past performance for risk is an evaluation element.


 


Small Business Subcontracting and Small Disadvantaged Business (SDB) Participation Plans.  The Offeror's approach in meeting/exceeding the DHHS goals for Small Business Subcontracting and Small Disadvantaged Business Participation Plans will be required. The price review will score the Offeror's stated Small Business Subcontracting goals verses the contract minimums. Additionally, the Offeror's actual participation in achieving previously stated participation goals will be evaluated. The Plans will also be reviewed by the NIH Small Business Office and the HHS PCR.


 


FULL SOLICIATION:
For full details, please see RFP #NIHOF2015030 - Date 12-15-2014 and supplemental attachments.


Note: One or more of the items under this acquisition is subject to the World Trade Organization Government Procurement Agreement and Free Trade Agreements.

Files

File Type Posted
RFP__NIHOF2015030_-_AMEND__00008.pdf PDF
RFP__NIHOF2015030_-_AMEND__00007.pdf PDF
RFP__NIHOF2015030_-_AMEND__00006.pdf PDF
RFP__NIHOF2015030_-_AMEND__00005.pdf PDF
RFP__NIHOF2015030_-_AMEND__00004.pdf PDF
RFP__NIHOF2015030_-_AMEND__00003.pdf PDF
RFP__NIHOF2015030_-_AMEND__00002.pdf PDF
A19_Other_Transformer_PCB_Results_04-2013.pdf PDF
A04_Past_Performance_Questionnaire_Part_I-II.pdf PDF
A18_Rpt_WO_12061908_ver_1_000.pdf PDF
RFP__NIHOF2015030_-_AMEND__00001.pdf PDF
A20_PPP_Vault_11_Access_Forum_06-16-14.pptx PPTX presentation
A08_DBWD_Mo_County.pdf PDF
A10_Proposal_Summary_and_Data_Record_NIH2043.pdf PDF
A13_Disclosure_of_Lobbting_Activites_SFLLL.pdf PDF
RFP NIHOF2015030 - Final 12-15-2014.pdf PDF
A17_ORF_Contractor_Health_Safety_Provisions.pdf PDF
A05_Similar_Project_Template.pdf PDF
A16_Section_3-1_NIH_Facilities_Dev_Manual.pdf PDF
A15_HHSAR-352.223-70-Safety-and-Health.pdf PDF
A03_Small_Business_Subcontracting_Plan.pdf PDF
RFP NIHOF2015030 - Final 12-15-2014.pdf PDF
A06_Summary_of_Related_Activities.pdf PDF
A07_Proposal_Cost_Summary_Backup_Info.xlsx XLSX spreadsheet
A12_Offerors_Point_of_Contact.pdf PDF
RFP NIHOF2015030 - Final 12-15-2014.pdf PDF
A04_Past_Performance_Questionnaire_Part_I-II.pdf PDF
A09_Indirect_Cost_Worksheet_Sample.pdf PDF
A14_NIH_RC_2_Invoice_Instructions_FFP.pdf PDF
A09_Indirect_Cost_Worksheet_Sample.xls XLS spreadsheet
A11_Cert_Current_Cost.pdf PDF
A02_Proposal_Intent_Response_Form.pdf PDF
A01_Packaging_and_Delivery_of_Proposal_NonRD.pdf PDF
RFP NIHOF2015030 - Final 12-15-2014.pdf PDF
RFP__NIHOF2015030_-_Final_12-15-2014.zip ZIP file