400 Hz Cycle Converters - Maintenance, Inspections, and Repairs
Open Solicitation Posted
- Solicitation number
- W51AA127QA004
- Agency
-
Department of the Army
Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 811210 Electronic and Precision Equipment Repair and Maintenance
- Place of performance
- Tobyhanna, Pennsylvania 18466, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Army, through Army Contracting Command (ACC) APG, Tobyhanna Division, is soliciting preventative maintenance, diagnostic inspections, and repairs for approximately 39 400 Hz cycle converters under Request for Quote W51AA1-27-Q-A004, with offers due December 14, 2026 at 4:00 PM local time. The procurement is a Total Small Business set-aside under NAICS 811210 (Electronic and Precision Equipment Repair and Maintenance) and PSC J059, with an SBA size standard of $34.0 million in average annual receipts. Offerors must register in SAM with no active exclusions and no delinquent federal debt.
Work is performed at Tobyhanna Army Depot, Tobyhanna, PA 18466. A site visit is scheduled for December 7, 2026 at 10:00 a.m. Questions go to Deborah Belak at deborah.belak.civ@army.mil and are due five calendar days before the response date.
The award is a firm-fixed-price purchase order under FAR Part 12 simplified procedures, covering a base year and four option years through February 2032. CLIN 6001 is a six-month extension option, and the Government has no obligation to exercise it. Scope includes quarterly Tier I preventative maintenance (4 lots annually), semi-annual Tier II (2 lots annually), and annual Tier III for idle or storage units (1 lot annually). Stage 1 emergency call-out requires 48-hour on-site response, with diagnostics and an itemized repair quote due within 15 calendar days. Stage 2 repairs are authorized through bilateral modification at direct cost, with no markup on parts or materials, and work starts within five business days of modification receipt. The contractor furnishes its own load banks and diagnostic equipment.
Key personnel are a Contract Manager with a minimum of five years of relevant experience and a Lead Field Service Technician with a minimum of eight years. Offerors must provide OSHA 30-Hour certificates. Security requirements include AT Level I and iWATCH training, OPSEC Level I training, CUI handling, and ALERT! MWNS enrollment for assignments exceeding seven days. The contractor must maintain a Quality Control Plan and retain documents for contract life plus five years.
Stage 2 CLIN 0005 is unpriced. Stage 2 emergency repairs are priced at a fully burdened hourly labor rate that is not evaluated for low bid but is analyzed for reasonableness, and proposed rates are contractually binding as maximum authorized charges. Service Contract Act Wage Determination 2015-5797, Revision 33, effective August 17, 2026, applies. The Total Evaluated Price combines the base year, all option years, and the CLIN 6001 extension, used for evaluation only, with the extension calculated at 50% of Option Year 4. Volume I contains the SF 1449, unit prices for CLINs 0001 through 0005 and option years, and the Proposed Pricing Worksheet. Volume II contains resumes for key personnel, OSHA certificates, and a capability narrative of no more than three pages. Offers must remain valid for 60 days from the due date.
Notice text
Request for Quote (RFQ) W51AA1-27-Q-A004 is being conducted in accordance with FAR Part 12, Acquisition of Commercial Products and Commercial Services and will utilize simplified procedures for soliciting competition, evaluation, award documentation and notification that complies with FAR Subpart 12.2.
The Army Contracting Command (ACC) APG, Tobyhanna Division intends to award a firm fixed price (FFP) purchase order to provide preventative maintenance, diagnostic inspections, and repairs on approximately thirty-nine (39) 400 Hz cycle converters located at Tobyhanna Army Depot, Tobyhanna PA 18466, in accordance with Attachment I, Performance Work Statement.
In accordance with FAR Clause 52.237-1, a single site visit will be conducted at Tobyhanna Army Depot on Monday, December 7, 2026, at 10:00 a.m.
This requirement is being solicited as a 100% small business set aside under NAICS 811210 (Electronic and Precision Equipment Repair and Maintenance) and PSC J059 (Maint/Repair /Rebuild of Equipment: Electrical and Electronic Equipment Components). The Small Business Administration (SBA) size standard for NAICS 811210 is $34.0 million (in average annual receipts).
Files
| File | Type | Posted |
|---|---|---|
| RFQ W51AA127QA004 - 400Hz Coverters.pdf | ||
| Attachment I Performance Work Statement.pdf | ||
| Attachment IV 400 Hz Converters List.xlsx | XLSX spreadsheet | |
| Attachment II Quality Assurance Surveillance Plan.pdf | ||
| Attachment III Proposed Pricing Worksheet.xlsx | XLSX spreadsheet | |
| Attachment V 648C Request for Access to TYAD.pdf |
Notice history
| Notice | Type | Posted |
|---|---|---|
| This notice | Solicitation | |
| 400 Hz Cycle Converters - Maintenance, Inspections, and Repairs | Pre-Solicitation | |
| 400 Hz Cycle Converters - Maintenance, Inspections, and Repairs | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Frequency Converters | Air Force Sustainment Center | No set-aside | |
| Power supply | Naval Supply Systems Command | No set-aside | |
| Repair of the TH-1H Servo Con Altimeter | Air Force Sustainment Center | No set-aside | |
| USNS COMFORT (T-AH 20) Aircraft 24VDC Rectifier and 400 Hz Converter | Military Sealift Command | No set-aside | |
| ACC-APG, Tobyhanna Division FY27 Fair Opportunity | ACC Aberdeen Proving Ground | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity