Attachment IV 400 Hz Converters List.xlsx
XLSX spreadsheet 14 KB Posted
- Solicitation number
- W51AA127QA004
- Issued by
-
Department of the Army
About this file
This file is a spreadsheet listing 400 Hz cycle converters maintained at Tobyhanna Army Depot. The attachment serves as a reference document supporting Request for Quote W51AA1-27-Q-A004, which solicits preventative maintenance, diagnostic inspections, and repairs for approximately thirty-nine (39) 400 Hz cycle converters located at Tobyhanna Army Depot in Tobyhanna, Pennsylvania. The converters are electrical and electronic equipment components requiring specialized maintenance and repair services.
The solicitation is issued by Army Contracting Command (ACC) APG, Tobyhanna Division as a firm fixed price purchase order under FAR Part 12 simplified acquisition procedures for commercial products and services. This is a 100% small business set-aside under NAICS 811210 (Electronic and Precision Equipment Repair and Maintenance) with a SBA size standard of $34.0 million in average annual receipts. A mandatory site visit is scheduled for Monday, December 7, 2026, at 10:00 a.m. at Tobyhanna Army Depot to allow interested contractors to inspect the equipment requiring maintenance and repair services.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| Attachment IV - 400 Hz Cycle Converters List (03-NOV-26) | ||||||||||
| Sequence # | Manufacture | Model # | Serial # | Input Voltage | Output Voltage | Output Power | Portable/ | |||
| Permanent | Indoor/ | |||||||||
| Outdoor | Tier | |||||||||
| 1 | Unitron Inc. | GFC-37F | 697 | 480 | 120/208 | 37 kva, | Permanent | Indoor | 1 | |
| 2 | FCX Systems | PFC080 | 11181 | 480 | 120/208 | 100 kva, 80 kw | Permanent | Outdoor | 2 | |
| 3 | FCX Systems | PFC016 | 11201 | 208 | 120/208 | 20 kva, 16 kw | Permanent | Indoor | 3 | |
| 4 | FCX Systems | PFC120-V-40-FN | 129920 | 480 | 120/208 | 150 kva, 120 kw | Permanent | Indoor | 2 | |
| 5 | FCX Systems | PFC120-V-40-FN | 79934 | 480 | 120/208 | 15 kva, 12 kw | Permanent | Indoor | ||
| 6 | ||||||||||
| 7 | Pillar Pwr Src | AJS C11-1-R-125-480/208-6/40-G-B | 9506039274 | 480 | 120/208 | 90 KVA | Permanent | Indoor | 3 | |
| 8 | ||||||||||
| 9 | Hobart | 125SX200 | 204PS08115 | 480 | 120/208 | 125 kva | Permanent | Indoor | 1 | |
| 10 | Hobart | 125SX200 | 405PS09791 | 480 | 120/208 | 125 kva | Permanent | Indoor | 3 | |
| 11 | FCX Systems | PFC100-H40-AN-CM4-WC | 8054 | 208 | 120/208 | 125 kva | Portable | Outdoor | 3 | |
| 12 | Bogue Systems | FCHD24-125 | 5595-1 | 208 | 208, 3ph | 90 kva, 72 kw | Permanent | Indoor | 2 | |
| 13 | Pillar Pwr Src | AJS C11-1-R-125-480/208-6/40-G-B | 9506039275 | 480 | 120/208 | 125 kva | Permanent | Outdoor | 1 | |
| 14 | Controlled Sys | FC-125-400-U-A (SATCON) | 93635-001 | 480 | 120/208 | 125 kva | Permanent | Indoor | 1 | |
| 15 | Piller | AJS C8-1-R-90-480/208-6/40 G-A | 9506042789 | 480 | 120/208, 3ph | 45 kva, 36 kw | Permanent | Indoor | 2 | |
| 16 | Hobart | 125SX200 | 305PS09346 | 480 | 120/208 | 125 kva | Permanent | Indoor | 2 | |
| 17 | Controlled Sys | FC-125-400-U-A (SATCON) | 94147-001 | 480 | 120/208 | 125 kva | Permanent | Indoor | 2 | |
| 18 | Piller | AJS C8-1-R-90-480-6/40 GA | 9506042790 | 480 | 115/200 | 60 kva | Permanent | Outdoor | 2 | |
| 19 | FCX Systems | PFC100-V-40-FN | 60064 | 480 | 120/208 | 125 kva, 100 kw | Permanent | Indoor | 1 | |
| 20 | FCX Systems | PFC100-V-40-FN | 12053 | 480 | 120/208 | 125 kva | Permanent | Indoor | 1 | |
| 21 | Controlled Sys | 100kw Power Supply EPU-5/E | J10422-A6 | 240,380,480 | 120/208 or 230-400 | 100 kw | Permanent | Indoor | ||
| 22 | Controlled Sys | FC1100-07-I-40-D/Y | J19-1265-20000509-02 | 480 | 208/120 | 125kva | Permanent | Indoor | 1 | |
| 23 | FCX Systems | PFC100-V-40-FN | 50814 | 480 | 120/208 | 125 kva, 100 kw | Permanent | Indoor | 1 | |
| 24 | FCX Systems | PFC100 | 8163 | 480 | 120/208 | 125 kva, 100 kw | Permanent | Outdoor | 3 | |
| 25 | ||||||||||
| 26 | FCX Systems | PFC100-V-40-FN | 5082 | 480 | 120/208 | 125 kva, 100 kw | Permanent | Indoor | 1 | |
| 27 | FCX Systems | PFC100-V-40-FN | 5083 | 480 | 120/208 | 125 kva, 100 kw | Permanent | Indoor | 1 | |
| 28 | FCX Systems | PFV100-V-40-FN | 5064 | 480 | 120/208 | 125 kva, 100 kw | Permanent | Indoor | 1 | |
| 29 | Unitron Inc. | GFC-125F | 813 | 208 | 120/208 | 125kva | Permanent | Indoor | 2 | |
| 30 | Unitron Inc. | GFC-15F | 771 | 208 | 115/200 | Permanent | Outdoor | 2 | ||
| 31 | FCX Systems | PFC080-V-40-AN-24P | 8031 | 208 | 120/208 | 100 kva, 80 kw | Permanent | Indoor | 2 | |
| 32 | Controlled Sys | EPU-6/E (50 kw) | J7759-C20 | 240,380,480 | 120-208 | 50 kw | Permanent | Indoor | 3 | |
| 33 | ||||||||||
| 34 | FCX Systems | PFC072-V-40-FN | 10094 | 120/208 | 30 kva | Portable | Outdoor | 3 | ||
| 35 | Pillar Pwr Src | AJS C5o-1-R-40-480/200-6/40-GB | 950 6005 177 | 480 | 115/200 | 40 kva | Permanent | Indoor | 1 | |
| 36 | Pillar Pwr Src | AJS C5o-1-R-40-480/200-6/40-GB | 950 6005 178 | 480 | 115/200 | 40 kva | Permanent | Indoor | 1 | |
| 37 | FCX Systems | PFC100-V-40-FN-24P-2-3R-FS18051122 | 51122 | 480 | 120/208 | 125 kva | Permanent | Outdoor | 1 | |
| 38 | ITW | FC-400-125-1-125 | 12867C4008 | 480 | 120/208 | 125 kva | Permanent | Indoor | 3 | |
| 39 | ITW | FC-400-125-1-125 | 12867C4009 | 480 | 120/208 | 125 kva | Permanent | Indoor | 2 | |
| 40 | Inet Airport Sys | SSP64V | 102006-01 | 480 | 120/208 | 125 kva | Permanent | Indoor | 2 | |
| 41 | Controlled Sys | FC1100-07-I-40-D/Y | J19-1265-20000509-01 | 480 | 120/208 | 125 kva | Permanent | Indoor | 2 | |
| X2 | Hobart | 125SX200 | 305PS09347 | 480 | 120/208 | 125 kva | Permanent | Outdoor | 3 | |
| P1 | FCX Systems | PFC100-H40-AN-CM4-NC | 60410 | 480 | 120/208 | 125 kva, 100 kw | Portable | Indoor | 3 | |
| P2 | FCX Systems | PFC024-V-40-AM-CB-3R | 10094 | 208 | 200/115 | 30 kva,24 kw | Portable | 3 |
File details come from the government source that posted it. Updated .