087100 door hardware.pdf

PDF 59 KB Posted

Attached to
CONSTRUCT USPFO WAREHOUSE
Solicitation number
W91364-09-B-0003
Issued by

About this file

087100 door hardware.pdf

View the file

Other files

File Type Posted
ADDENDUM NO 03 USPFO Narrative.pdf PDF
ADDENDUM NO 03 CSMS PH II Narrative.pdf PDF
USPFO_S201W.pdf PDF
E101.pdf PDF
E404.pdf PDF
USPFO_S002W.pdf PDF
262726 wiring devices.pdf PDF
000 USPFO Specs Combined.pdf PDF
220519 meters and gages for plumbing piping.pdf PDF
USPFO_S401W.pdf PDF
013300d attachment submittal register.pdf PDF
095113 acoustical panel ceilings.pdf PDF
224500 emergency plumbing fixtures.pdf PDF
015000 temporary facilities and controls.pdf PDF
072410 polymer-based exterior finish system —
C500.pdf PDF
USPFO_F303W.pdf PDF
USPFO_M401W.pdf PDF
USPFO_FA602W.pdf PDF
OHARNG-USPFO-A-212bW .pdf PDF
079200 joint sealants.pdf PDF
OHARNG-USPFO-A-724W .pdf PDF
I101.pdf PDF
USPFO_P601W.pdf PDF
088500 decorative film for glass.pdf PDF
OHARNG-USPFO-A-816W .pdf PDF
079500 expansion control.pdf PDF
013100 project management and coordination.pdf PDF
OHARNG-USPFO-A-415W .pdf PDF
099113 exterior painting.pdf PDF
USPFO_S212W.pdf PDF
012300 optional bid items.pdf PDF
220548 vibration and seismic controls for plumbing piping and equipment.pdf PDF
220529 hangers and supports for plumbing piping and equipment.pdf PDF
104416 fire extinguishers.pdf PDF
230553 identification for hvac piping and equipment.pdf PDF
263323 central battery equipment.pdf PDF
275116 public address system.pdf PDF
OHARNG-USPFO-G-115W .pdf PDF
OHARNG_USPFO_Q203W.pdf PDF
E502.pdf PDF
018113 sustainable design requirements.pdf PDF
210500 common work results for fire suppression.pdf PDF
OHARNG-USPFO-G-120W .pdf PDF
260543 underground ducts and raceways for electrical systems.pdf PDF
262816 enclosed switches and circuit breakers.pdf PDF
OHARNG-USPFO-A-710W .pdf PDF
E302.pdf PDF
C200.pdf PDF
019113 general commissioning requirements.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

F5W61608 USPFO Warehouse Ohio Army National Guard Rev. 0 Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final

DOOR HARDWARE 087100 - 1

SECTION 087100 - DOOR HARDWARE

PART 1 - GENERAL

1.1 SUMMARY

A. Section Includes:

1. Work under this section comprises of furnishing and installing commercial door hardware needed for a complete and operational system for the following.

a. Swinging doors.

2. Cylinders for doors specified in other sections.

3. Electrified door hardware.

B. Products supplied but not installed under this Section:

1. Hardware for aluminum doors will be furnished under this Section, but installed under Section 08400 Entrances and Storefronts.

1.2 RELATED DOCUMENTS

A. Drawings, Instructions to Bidders, General Conditions, Special Conditions and Division 1 General Requirements govern the work of this Section.

1.3 DESCRIPTION OF WORK

A. Work under this Section comprises of furnishing and installing hardware as specified and as noted in Part 3 and as required for a complete door operational system including electrified hardware components, systems, controls and hardware for aluminum doors.

B. Hardware listed is intended to cover doors and establish a type and quality. Hardware supplier shall examine appropriate Drawings and Specifications for proper hardware use for each opening.

C. Hardware not specified within specification or hardware sets but necessary for completion of work shall be provided.

D. When a door appears on Drawings without being listed one Door Schedule or when a door appears on Door Schedule without being on Drawings, provide hardware equal to that of a similar door then call out omissions to Architect prior to award of contract.

Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final

DOOR HARDWARE 087100 - 2

1.4 REFERENCES

A. American National Standards Institute/Builders Hardware Manufacturers Association

(ANSI):

1. ANSI/BHMA A156.1 Butts & Hinges (2006)

2. ANSI/BHMA A156.3 Exit Devices (2001)

3. ANSI/BHMA A156.4 Door Controls – Closers (2000)

4. ANSI/BHMA A156.6 Architectural Door Trim (2005)

5. ANSI/BHMA A156.7 Template Hinge Dimensions (2003)

6. ANSI/BHMA A156.8 Door Controls – Overhead Stops and Holders (2005)

7. ANSI/BHMA A156.13 Mortise Locks & Latches (2005)

8. ANSI/BHMA A156.16 Auxiliary Hardware (2002)

9. ANSI/BHMA A156.18 Materials & Finishes (2006)

10. ANSI/BHMA A156.19 Power Assist & Low Energy Power Operated Doors

(2007)

11. ANSI/BHMA A156.21 Thresholds (2006)

12. ANSI/BHMA A156.22 Door Gasketing Systems (2005)

13. ANSI/BHMA A156.26 Continuous Hinges (2006)

14. ANSI/BHMA A156.28 Keying Systems (2008)

15. ANSI/BHMA A156.31 Electric Strikes (2007)

B. International Code Council/American National Standards Institute (ICC/ANSI):

1. ICC/ANSI A117.1 Standards for Accessible and Usable Buildings and Facilities (1998).

C. Underwriters Laboratories, Inc. (UL):

1. UL 10C Positive Pressure Fire Test of Door Assemblies

D. Door and Hardware Institute (DHI):

1. DHI Handbook – Keying Systems and Nomenclature (1989)

2. Architectural Hardware Consultant (AHC)

E. National Fire Protection Agency (NFPA)

1. NFPA 80 Standard for Fire Doors and Other Opening Protectives (2007)

2. NFPA 101 Life Safety Code (2006)

3. NFPA 105 Standard for the Installation of Smoke Door Assemblies (2003)

1.5 SUBMITTALS

A. Submit six copies of submittals in accordance with Conditions of the Contract and Division 1 Section 01300 Administrative Requirements.

Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final

DOOR HARDWARE 087100 - 3

B. Shop Drawings:

1. Hardware schedule shall be organized in vertical format illustrated and published by DHI in Sequence and Formatting for the Hardware Schedule.

Complete nomenclature of items required for each door opening as indicated.

Hardware supplier shall have responsibility of reviewing existing conditions, schedules, specifications, drawings and contract documents to verify suitability of specified hardware. Notify Architect a minimum of 10 days before bid of omissions, discrepancies and items believed to be contrary to applicable codes, laws, statutes and regulations.

2. Hardware schedule shall be reviewed prior to submittal by an Architectural Hardware Consultant (AHC), as certified by DHI, who shall affix seal attesting to the completeness and correctness by hardware supplier.

C. Submit manufacturer’s catalog sheet on design, grade and function of all items listed in hardware schedule. Identify specific hardware item per sheet and provide index cover sheet.

D. Templates for finished hardware items to be sent to related Sections upon receipt of approved hardware schedule. Copies of transmittals sent to contractor.

E. Details of electrified door hardware, indicate the following:

1. Wiring Diagrams:

a. Point to point wiring diagram.

b. Riser diagram.

c. System schematic.

d. Elevation diagram of each electrified opening.

2. Description of operation for each electrified opening to include description of component functions including location, sequence of operation and interface with other building control systems.

F. LEED submittals: Submit data on rapidly renewable materials:

1. Agriculture products harvested within a ten year cycle.

2. Regionally manufactured materials within five hundred miles of project.

3. Regionally extracted, harvested and recovered materials within five hundred miles.

4. Recycled content, percentage by weight of constituents per-consumer and post-consumer as applicable to product

G. Closeout Submittals: Submit to Owner in a three ring binder.

1. Warranties.

2. Maintenance and operating manual.

Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final

DOOR HARDWARE 087100 - 4

3. Maintenance service agreement.

4. Record documents.

5. Copy of approved hardware schedule.

6. Copy of approved keying schedule with bitting list.

1.6 QUALITY ASSURANCE

A. Hardware supplier shall employ an Architectural Hardwar Consultant (AHC) as certified by DHI and a member of the seal program who shall be available at reasonable times during course of work for Project hardware consultation.

B. Openings shall conform to the American Disability Act Accessibility Guidelines (A.D.A.A.G.).

C. Fire Rated openings: Furnish hardware for fire rated openings which are listed and labeled and have been tested by Underwriters Laboratory (UL), Factory Mutual (FM) or Warnock Hersey (WH) or an acceptable inspecting agency to Authority Having Jurisdiction (AHJ).

D. Locks, closers and exit devices shall be certified to ANSI/BHMA standards as noted, participate and be listed in the certified products program.

E. Pre-Installation Conference: Conduct conference at Project site to comply with requirements in Division 1 Section “Project Meetings.”

1. Include in conference decisions regarding proper installation methods and procedures for receiving and handling hardware.

2. Review sequence of operation for each type of electrified door hardware and inspect and discuss electrical roughing-in and other preparatory work performed by other trades.

3. Review and finalize construction schedule and verify availability of materials, installer’s personnel, equipment and facilities needed to make progress and avoid delays.

F. Door hardware shall be in accordance with applicable Local Building Codes.

G. Installer Qualifications: Installer shall specialize in performing installation work of this Section and shall have 5 years minimum documented experience in installation and maintenance of type and quality required for work and acceptable to hardware supplier and manufacturers as applicable.

1.7 DELIVERY, STORAGE, AND HANDLING

A. Provide a clean, dry and secure room for hardware delivered to Project but not yet installed.

Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final

DOOR HARDWARE 087100 - 5

B. Furnish hardware with each unit marked and numbered in accordance with approved finish hardware schedule. Include door and item number for each type of hardware.

C. Pack each item complete with necessary parts and fasteners in manufacturer’s original packaging.

D. Deliver permanent key, cores, access control credentials, software and related accessories directly to Owner via registered mail or overnight package service.

Instructions for delivery to Owner shall be established at “Keying Conference.”

E. Waste Management and Disposal

1. Separate waste materials for reuse or recycling in accordance with Division 1- Section 01300 Administration Requirements, Waste Management and Disposal.

1.8 WARRANTY

A. General Warranty: Owner may have under provisions of the Contract Documents and shall be an addition and run concurrent with other warranties made by Contractor under requirements of the Contract documents.

B. Special Warranty: Warranties specified in this article shall not deprive Owner of other rights. Contractor, hardware supplier, hardware supplier and hardware installer shall be responsible for servicing hardware and keying related problems.

1. Ten years for manual door closers.

2. Five years for mortise, auxiliary and bored locks.

3. Five years for exit devices.

4. Two years for electromechanical door hardware.

C. Products judged to be defective during the warranty period will be replaced or repaired in accordance with manufacturer’s warranty at no cost to the Owner. There is no warranty against defects due to improper installation, abuse and failure to exercise normal maintenance.

PART 2 - PRODUCTS

2.1 MATERIALS

A. General Requirements:

1. Hardware shall be free of imperfections in manufacture and finish.

2. Furnish necessary screws, bolts or other fastenings of suitable size and type to anchor hardware and match hardware in material and finish. Provide Phillips

Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final

DOOR HARDWARE 087100 - 6

flat-head screws, undercut as required for material thickness, except as otherwise indicated in hardware schedule.

3. Drawings show direction of slide, swing or hand of each door leaf. Furnish each item of hardware for proper installation and operation of door movement as indicated. Provide items of hardware not definitely specified, but needed for satisfactory installation.

2.2 HINGES

A. Hinges, continuous hinges, electric hinges, single and double acting pivots shall be of one manufacturer as listed for continuity of design and consideration of warranty.

B. Standards: Products to be certified by the following.

1. Hinges: ANSI/BHMA A156.1

2. Template Hinge Dimensions: ANSI/BHMA A156.7

3. Continuous Hinges: ANSI/BHMA A156.26

C. Butt Hinges:

1. Hinge weight and size unless otherwise indicated in hardware sets:

a. Doors up to 36” wide and up to 1-3/4” thick provide hinges with a minimum thickness of .134” and a minimum of 4-1/2” in height.

b. Doors from 36” wide up to 42” wide and up to 1-3/4” thick provide hinges with a minimum thickness of .145” and a minimum of 5” in height.

c. For doors from 42” wide up to 48” wide and up to 1-3/4” thick provide hinges with a minimum thickness of .180” and a minimum of 5” in height.

d. Doors greater than 1-3/4” thick provide hinges with a minimum thickness of .180” and a minimum of 5” in height.

e. Width of hinge is to be minimum required to clear surrounding trim.

2. Base material unless otherwise indicated in hardware sets:

a. Exterior Doors: 304 Stainless Steel, Brass or Bronze material.

b. Interior Doors: Steel material.

c. Fire Rated Doors: Steel or 304 Stainless Steel materials.

3. Quantity of hinges per door:

a. Doors up to 60”in height shall have 2 hinges.

b. Doors 60” up to 90” in height shall have 3 hinges.

c. Doors 90” up to 120” in height shall have 4 hinges.

d. Doors over 120” in height add 1 additional hinge per each additional 30” in height.

e. Dutch doors shall have 4 hinges.

Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final

DOOR HARDWARE 087100 - 7

4. Hinge design and options unless otherwise indicated in hardware sets:

a. All hinges are to be of a square corner five knuckle design, flat button tips and have ball bearings unless otherwise indicated in hardware sets. Out-swinging exterior and out-swinging access controlled doors shall have non-removable pins (NRP) to prevent removal of pin while door is in closed position.

b. When full width of opening is required, use hinges that are designed to swing door completely from opening when door is opened to 95 degrees.

c. Electric Through Wire (ETW) to have appropriate number of wires to transfer power through door frame to door for proper connection of finish hardware and certified to handle an amperage rating of 3.5AMPS/continuous duty with 16.0AMPS/intermittent duty.

d. Provide mortar boxes for frames that require any electrically modified hinges if not an integral part of the frame.

e. When shims are necessary to correct frame or door irregularities, provide metal shims only.

5. Acceptable Manufactures:

a. Hager Companies.

b. Bommer Industries, Inc.

c. Stanley Hardware, a division of Stanley Security Solutions.

D. Continuous Geared Hinges:

1. Hinge weight and size requirements unless otherwise indicated in hardware sets:

a. Choose proper weight of hinge according to manufacturers recommendations taking into consideration the weight of the door, weight of all finish hardware applied to the door, location and frequency of usage.

b. Size of hinge to be 1” less door height.

2. Base material: Anodized aluminum manufactured from 6063-T6 material, all unexposed working metal surfaces shall be coated with TFE dry lubricant

3. Bearings:

a. Vertical loads shall be carried on Lubriloy RL bearings for non Fire Rated doors.

b. Standard weight hinges shall have a minimum spacing between bearings of 5-1/8”. Typical door from 80” to 84” in height to have a minimum of 16 bearings.

Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final

DOOR HARDWARE 087100 - 8

c. Heavy Weight hinges shall have a minimum spacing between bearings of 2-9/16”. Typical door from 80” to 84” in height to have a minimum of 32 bearings.

4. Hinge Design and Options:

a. Electric Through Wire (ETW) shall have appropriate number of wires to transfer power through door frame to door for proper connection of finish hardware. Provide ETW in a form that can be removed for connection and servicing without removing entire hinge from door and frame and certified to handle an amperage rating of 3.5AMPS/continuous duty with 16.0AMPS/intermittent duty.

b. All hinges shall have Rounded Back Cover Channel (RBCC).

c. When full width of opening is required, use hinges that are designed to swing door completely from opening when door is opened to 95 degrees.

d. Fire rated hinges shall carry UL certification, up to and including 90 minute applications for wood doors and up to 3 hour applications for metal doors.

5. Acceptable Manufactures:

a. Hager Companies.

b. Select Hinges

c. Stanley Hardware, a division of Stanley Security Solutions.

2.3 LOCKS AND LATCHES

A. Locks and latches shall be of one manufacturer as listed for continuity of design and consideration of warranty.

B. Standards: Product to be certified and listed by following:

1. ANSI/BHMA A156.13 Series 1000 Certified to Grade 1 for Operational and Security.

2. UL/cUL Labeled and listed for all functions up to 3 hours for single doors up to 48” in width and up to 96” in height.

3. UL10C/UBC 7-2 Positive Pressure Rated.

4. ICC/ANSI A117.1.

C. Lock and latch function numbers and descriptions of manufactures series as listed in hardware sets.

D. Material and Design:

1. Lock cases from fully wrapped, 12 gauge steel, Zinc dichromate for corrosion resistance.

Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final

DOOR HARDWARE 087100 - 9

2. Non-handed, field reversible without opening lock case.

3. Break away spindles to prevent unlocking during forced entry or vandalism.

4. Levers are to be Zinc cast, Forged Brass or Stainless Steel and plated to match finish designation in hardware sets.

5. Sectional Roses are to be of solid Brass or Stainless Steel material and have a minimum diameter of 2-7/16”.

6. Armor fronts are to be self adjusting to accommodate a square edge door or a standard 1/8” beveled edge door.

E. Latch and Strike:

1. Stainless Steel latch bolt with minimum of ¾” throw and deadlocking for all keyed and exterior functions.

2. Strike is to fit a standard ANSI A115 prep measuring 1-1/4” x 4-7/8” with proper lip length to protect surrounding trim.

3. Deadbolts to be 1-3/4” total length with a minimum of a 1” throw and ¾” internal engagement when fully extended and made of Stainless Steel material.

F. Options:

1. Doors requiring lead line protection provide locks with 1/16” lead applied to the lock and 1/16” lead wrapped around the latch bolt.

2. Provide knurled levers on entry side of doors that are potentially dangerous to visually impaired persons.

G. Acceptable Manufactures:

1. Hager Companies.

2. Schlage, an Ingersoll-Rand Company.

3. Best Access Systems, a division a Stanley Security Solutions.

2.4 EXIT DEVICES

A. Shall be touch pad type, finish to match balance of door hardware.

B. Standards: Manufacturer to be certified by the following:

1. Exit Devices: ANSI/BHMA A156.3 Grade 1

2. UL labeled panic exit hardware.

3. UL labeled fire exit hardware.

C. Touch pad shall extend a minimum of one half door width. Free-wheeling lever design shall match design of locks levers. Exit device to mount flush with door.

D. Components:

Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final

DOOR HARDWARE 087100 - 10

1. Covers and end caps shall be brass, bronze, or stainless steel.

2. Devices to have dead latching feature to prevent latch bolt tampering.

E. Lock and Latch Functions: Function numbers and descriptions of manufacturer’s series and lever styles indicated in door hardware sets.

F. Fasteners:

1. Wood and machine screws and thru-bolts.

G. Acceptable Manufactures:

1. Hager Companies.

2. Adams Rite Manufacturing Co., an ASSA ABLOY Group Company.

3. Von Duprin, an Ingersoll-Rand Company.

2.5 CYLINDERS AND KEYING

A. Cylinders shall be from Best manufacturer.

B. Standards:

1. DHI Handbook “Keying systems and nomenclature” (1989).

C. Cylinders:

1. Construct all cores so that they will be interchangeable into the housings of all mortise locks, rim locks, cylindrical locks and any other type of lock.

Disassembly of lever or lockset shall not be required to remove core from lockset.

2. Furnish with cams/tailpieces as required for the locking device that is being furnished for the project.

D. Keying

1. Contact Owner with representative from hardware supplier to establish a keying conference. Verify keyway, visual key identification, number of master keys and keys per lock. Provide keying system per Owners instructions.

2. Copy of Owners approved keying schedule shall be submitted to Owner and Architect with documentation of whom the keying conference was held and the Owners sign-off.

3. Provide a bitting list to the Owner of all combinations as established, and expand to twenty five percent for future use or as directed by Owner.

4. Key into Owner’s existing keying system if applicable.

Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final

DOOR HARDWARE 087100 - 11

5. Keys to be shipped to Owner’s representative, individually tag per the keying conference.

6. Provide visual key control identification on keys.

7. Provide interchangeable cores with construction cores as required per the hardware schedule.

2.6 CLOSERS

A. Shall be the product of one manufacturer. Unless otherwise indicated on hardware schedule, comply with manufacturer’s recommendation for size of closer, depending on width of door, frequency of use, atmospheric pressure, ADAAG requirements, and fire rating.

B. Standards: Manufacturer to be certified and or listed by the following:

1. Closers ANSI/BHMA A156.4 Grade 1

2. ADAAG

3. ICC/ANSI A117.1

4. UL/cUL listed up to 3 hours.

5. UL10C Positive Pressure Rated

C. Provide cast iron non-handed bodies with full plastic covers. Closers shall have separate staked adjustable valve screws for latch speed, sweep speed, and backcheck. Provide Tri-Pack arms and brackets for regular arm, top jamb, and parallel arm mounting for each closer.

D. Components:

1. One piece seamless steel spring tube to seal in hydraulic fluid.

2. Double heat treated steel tempered springs.

3. Precision machined heat treated steel piston.

4. Triple heat treated steel spindle.

5. Full rack and pinion operation.

E. Mounting:

1. Out swing doors shall have surface parallel arm mount closers except where noted on hardware schedule.

2. In swing doors shall have surface regular arm mount closers except where noted on hardware schedule.

3. Provide brackets and shoe supports for aluminum doors and frames to mount fifth screw.

4. Furnish drop plates where top rail conditions on door do not allow for mounting of closer and where backside of closer is exposed through glass.

Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final

DOOR HARDWARE 087100 - 12

F. Fasteners: Provide self reaming and self-tapping wood and machine screws and sex nuts and bolts for each closer.

G. Acceptable Manufactures:

1. Hager Companies.

2. Norton, an ASSA ABLOY Group Company.

3. LCN, an Ingersoll-Rand Company

2.7 AUTOMATIC DOOR OPERATORS

A. Provide and install operators where indicated. Refer to Section 087113, Automatic Door Operators, for operator and actuator requirements.

2.8 ELECTRIC STRIKES

A. Provide for use with type of locks shown on hardware schedule.

B. Provide power supply to filter and regulate voltage to electric strike.

C. Standards: Manufacturer to be certified by the following:

1. ANSI/BHMA A156.31 Electric Strikes and Frame Mounted Actuators

2. UL listed as Burglary-Resistant Electric Door Strike.

3. UL listed for Fire Doors and Frames where applicable.

D. Acceptable Manufactures:

1. Rutherford Controls

2. HES, an ASSA ABLOY Group Company.

3. Security Door Controls

2.9 CARD READERS

A. Provide and install card readers where indicated. Refer to Section Access Control Systems, for card reader requirements.

2.10 FLUSH BOLTS AND COORDINATORS

A. Labeled openings: Provide automatic or constant latching flush bolts per hardware schedule for inactive leaf of pairs of doors. Provide dust proof strikes for bottom bolt.

Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final

DOOR HARDWARE 087100 - 13

B. Non-Labeled openings: Provide two flush bolts for inactive leaf of pairs of doors per hardware schedule. Top bolt shall not be more than 78” centerline from floor.

Provide dust proof strike for bottom bolt.

C. Acceptable Manufactures:

1. Hager Companies.

2. Rockwood Manufacturing Company, an ASSA ABLOY Group Company.

3. Trimco Architectural Hardware.

2.11 PUSH PLATES AND PULL PLATES

A. Push plates: .050” thick, square corner and beveled edges with counter sunk screw holes. Width and height as stated in Hardware schedule.

B. Pull plates: .050” thick, square corner and beveled edges. Width and height as stated in door schedule, ¾” diameter pull, with clearance of 2-1/2” from face of door.

C. Standards: Manufacturer to be certified by the following:

1. Architectural Door Trim: ANSI/BHMA A156.6

2. Americans with Disabilities Act Accessibility Guidelines (ADAAG).

D. Acceptable Manufactures:

1. Hager Companies.

2. Rockwood Manufacturing Company, an ASSA ABLOY Group Company.

3. Trimco Architectural Hardware.

2.12 PROTECTIVE TRIM

A. For single doors, size two inches less door width (LDW) on push side of door, and one inch less on pull side of door by 8” high. For pairs of doors, size one inch less door width (LDW) on push side of door, and ½ inch on pull side of door. Kick plates shall be 8” high and armor plates shall be 36” high.

B. Standards: Manufacturer to be certified by the following:

1. Architectural Door Trim: ANSI/BHMA A156.6

2. UL

C. Armor plates and kick plates shall be 0.050” thick stainless steel, beveled all four edges with countersunk holes.

D. Fasteners: Supply #6 x 5/8” oval head screws, unless otherwise noted.

Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final

DOOR HARDWARE 087100 - 14

E. Acceptable Manufactures:

1. Hager Companies.

2. Rockwood Manufacturing Company, an ASSA ABLOY Group Company.

3. Trimco Architectural Hardware.

2.13 STOPS AND HOLDERS

A. Provide door stops wherever necessary to prevent door or hardware from striking an adjacent partition or obstruction. Provide wall stops whenever possible. Door stops and holders mounted in concrete floor or masonry walls shall have stainless steel machine screws and lead expansion shields.

B. Standards: Manufacturer to be certified by the following:

1. Stops and Bumpers: ANSI/BHMA A156.8

C. Acceptable Manufactures:

1. Hager Companies.

2. Rockwood Manufacturing Company, an ASSA ABLOY Group Company.

3. Trimco Architectural Hardware.

2.14 DOOR GASKETING AND WEATHERSTRIP

A. Provide continuous weatherstrip gasketing on exterior doors and provide smoke, light, or sound gasketing where indicated on hardware schedule. Provide non-corrosive fasteners for exterior applications.

1. Perimeter gasketing: Apply to head and jamb, forming seal between door and frame.

2. Meeting stile gasketing: Fasten to meeting stiles, forming seal when doors are in closed position.

3. Door bottoms: Apply to bottom of door, forming seal with threshold or floor when door is in closed position.

4. Sound Gasketing: Cutting or notching for stop mounted hardware not permitted.

5. Where rain drips are specified in hardware sets, size to full width of frame.

B. Standards: Manufacturer to be certified by the following:

1. Door Gasketing and Edge Seal Systems: ANSI/BHMA A156.22

Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final

DOOR HARDWARE 087100 - 15

C. Smoke-Labeled Gasketing: Comply with NFPA 105 listed and labeled and acceptable to authorities having jurisdiction, for smoke control indicated.

1. Provide smoke labeled gasketing on 20 minute rated doors and on smoke rated doors.

D. Fire-Rated Gasketing: Comply with NFPA 80 listed and labeled and acceptable to Authorities Having Jurisdiction, for fire ratings indicated.

E. Comply with UBC 7-2 and UL10C positive pressure where frame applied intumescent seals are required.

F. Acceptable Manufactures:

1. Hager Companies.

2. National Guard Products

3. Pemko, an ASSA ABLOY Group Company

2.15 THRESHOLDS

A. Secured with lead expansion shields and stainless steel machine screws. Notched in field to fit frame by hardware installer. Refer to Drawings for special details.

B. Standards: Manufacturer to be certified by the following:

1. Thresholds: ANSI/BHMA A156.21

2. Americans with Disabilities Act Accessibility Guidelines (ADAAG).

C. Acceptable Manufactures:

1. Hager Companies.

2. National Guard Products

3. Pemko, an ASSA ABLOY Group Company

2.16 SILENCERS

A. Where smoke, light, or weather seal are not required provide three silencers per single door frame, two per double door frame and four per Dutch door frame.

B. Acceptable Manufactures:

1. Hager Companies.

2. Rockwood Manufacturing Company, an ASSA ABLOY Group Company.

3. Trimco Architectural Hardware.

Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final

DOOR HARDWARE 087100 - 16

2.17 KEY CABINET

A. Provide key cabinet by Lund Equipment, Telkee Incorporated, or Key Control.

B. Key control system:

1. Include two sets of key tags, hooks, labels, and envelopes.

2. Contain system in metal cabinet with baked enamel finish, surface mounted to wall.

3. Capacity shall be able to hold actual quantities of keys, plus 25 percent.

4. Provide tools, instruction sheets and accessories required to complete installation.

2.18 FINISHES

A. Appearance of Finished Work: Variations in appearance of abutting or adjacent pieces are acceptable if within range of approved Samples. Noticeable variations in the same piece are not acceptable. Variations in appearance of other components are acceptable if they are within range of approved Samples.

PART 3 - EXECUTION

3.1 EXAMINATION

A. Examine doors, frames and related items for conditions that would prevent proper application of finish hardware. Do not proceed until all deficiencies have been corrected.

3.2 INSTALLATION

A. Install hardware per manufacturer’s instructions and in compliance with:

1. NFPA 80.

2. NFPA 105.

3. ICC/ANSI A117.1.

4. ANSI/BHMA A115.

5. UL10C/UBC7-2

6. Local building code.

7. Approved shop drawings.

8. Approved finish hardware schedule.

Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final

DOOR HARDWARE 087100 - 17

B. Do not install surface mounted items until finishes have been completed on substrates involved. Set unit level, plumb and true to line location. Adjust and reinforce attachment substrate as necessary for proper installation and operation.

3.3 FIELD QUALITY CONTROL

A. Material supplier to schedule final walk through to inspect hardware installation ten business days before final acceptance of Owner. Material supplier shall provide a written report detailing discrepancies of each opening to General Contractor within five business days of walk through.

3.4 ADJUSTMENT, CLEANING AND DEMONSTRATING

A. Adjustment: Adjust and check each opening to ensure proper operation of each item of finish hardware. Replace items that cannot be adjusted to operate freely and smoothly or as intended for the application at no cost to Owner.

B. Cleaning: Clean adjacent surfaces soiled by hardware installation. Clean finished hardware per manufacturer’s instructions after final adjustments has been made.

Replace items that cannot be cleaned to manufacturer’s level of finish quality at no cost to Owner.

C. Demonstration: Hardware supplier to conduct a training class for the building maintenance personnel demonstrating the adjustment, operation of mechanical and electrical hardware. Special tools for finished hardware to be turned over and explained usage at this meeting.

3.5 PROTECTION

A. Leave manufacturer’s protective film intact and provide proper protection for all other finish hardware items that do not have protective material from the manufacture until Owner accepts Project as complete.

3.6 HARDWARE SETS

A. The following schedule of hardware sets shall be considered a guide only and hardware supplier is cautioned to refer to general conditions, special conditions and the preamble of this Section for proper finish hardware selection for each door opening on door schedule and contract drawings. Hardware supplier shall be responsible to furnish all required finish hardware to meet required codes.

3.7 HARDWARE SCHEDULE

Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final

DOOR HARDWARE 087100 - 18

HDW SET 1

Door Numbers: 113B Each opening to receive:

2 ea Continuous Geared Hinge 780-224HD x RBCC

2 sets Push/Pull H157D 630 2 ea Closers 5100 x HDS 689 2 ea Brackets 5110 x 5113 689

Note: Meeting stile and weatherstrip provided by door manufacture.

HDW SET 2

Door Numbers: 101B Each opening to receive:

2 ea Continuous Geared Hinge 780-224HD x RBCC

2 sets Push/Pull H157D 630 1 ea Auto Operator 9531 689 1 ea Closer 5100 x HDS 689 1 ea Brackets 5110 x 5113 689 1 ea Actuator 8310-856T 630

Note: Meeting stile and weatherstrip provided by door manufacture.

Description of Operation:

Doors are normally in the closed position.

Pushing either interior or exterior actuator will activate automatic operator to open active door.

Door operators as manually door closer during power failure.

Actuator pads will be inactive during fire alarm or power failure.

Free egress at all times.

HDW SET 3

Door Numbers: 110, 111 Each opening to receive:

3 ea Hinges BB1279 x 4-1/2” x 4-1/2” 652 1 ea Pull Plate H33J x 4” x 16” 630 1 ea Push Plate 30S x 4” x 16” 630 1 ea Closer 5100 689 1 ea Kick Plate 194S 630 1 ea Wall Stop 232W 630 3 ea Silencers 307D GREY

Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final

DOOR HARDWARE 087100 - 19

HDW SET 4

Door Numbers: 107 Each opening to receive:

3 ea Hinges BB1279 x 4-1/2” x 4-1/2” 652 1 ea Passage 3810 x ARC 630 1 ea Wall Stop 232W 630 3 ea Silencers 307D GREY

HDW SET 5

Door Numbers: 104, 105, 119, 120 Each opening to receive:

3 ea Hinges BB1279 x 4-1/2” x 4-1/2” 652 1 ea Office Lock 3850 x ARC 630 1 ea Cylinder 1E74 626 1 ea Wall Stop 232W 630 3 ea Silencers 307D GREY

HDW SET 6

Door Numbers: 116A Each opening to receive:

3 ea Hinges BB1279 x 4-1/2” x 4-1/2” 652 1 ea Office Lock 3850 x ARC 630 1 ea Cylinder 1E74 626 1 ea Closer 5100 689 1 ea Kick Plate 194S 630 1 ea Wall Stop 232W 630 3 ea Silencers 307D GREY

HDW SET 7

Door Numbers: 116B Each opening to receive:

3 ea Hinges BB1279 x 4-1/2” x 4-1/2” 652 1 ea Office Lock 3850 x ARC 630 1 ea Cylinder 1E74 626 1 ea Closer 5100 689 1 ea Kick Plate 194S 630 1 ea Wall Stop 232W 630 1 ea Smoke Seal 726S CHARCOAL

HDW SET 8

Door Numbers: 103, 108, 121B Each opening to receive:

Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final

DOOR HARDWARE 087100 - 20

3 ea Hinges BB1279 x 4-1/2” x 4-1/2” 652 1 ea Classroom Lock 3870 x ARC 630 1 ea Cylinder 1E74 626 1 ea Closer 5100 689 1 ea Kick Plate 194S 630 1 ea Wall Stop 232W 630 3 ea Silencers 307D GREY

HDW SET 9

Door Numbers: 106 Each opening to receive:

3 ea Hinges BB1279 x 4-1/2” x 4-1/2” 652 1 ea Classroom Lock 3870 x ARC 630 1 ea Cylinder 1E74 626 1 ea Closer 5100 689 1 ea Kick Plate 194S 630 1 ea Wall Stop 232W 630 1 ea Smoke Seal 726S CHARCOAL

HDW SET 10

Door Numbers: 118 Each opening to receive:

6 ea Hinges BB1279 x 4-1/2” x 4-1/2” 652 2 ea Flush Bolts 282D 626 1 ea Dust Proof Strike 280X 626 1 ea Classroom Lock 3870 x ARC 630 1 ea Cylinder 1E74 626 2 ea Wall Stops 232W 630 2 ea Silencers 307D GREY

Note: Astragal provided by door manufacture.

HDW SET 11

Door Numbers: 121A Each opening to receive:

6 ea Hinges BB1279 x 4-1/2” x 4-1/2” 652 2 ea Flush Bolts 282D 626 1 ea Dust Proof Strike 280X 626 1 ea Classroom Lock 3870 x ARC 630 1 ea Cylinder 1E74 626 2 ea Closers 5100 689 2 ea Armor Plates 194S 630

Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final

DOOR HARDWARE 087100 - 21

2 ea Wall Stops 232W 630 2 ea Silencers 307D GREY

Note: Astragal provided by door manufacture.

HDW SET 12

Door Numbers: 109, 112 Each opening to receive:

3 ea Hinges BB1279 x 4-1/2” x 4-1/2” 652 1 ea Storeroom Lock 3880 x ARC 630 1 ea Cylinder 1E74 626 1 ea Closer 5100 689 1 ea Kick Plate 194S 630 1 ea Wall Stop 232W 630 3 ea Silencers 307D GREY

HDW SET 13

Door Numbers: 117 Each opening to receive:

3 ea Hinges BB1279 x 4-1/2” x 4-1/2” 652 1 ea Storeroom Lock 3880 x ARC 630 1 ea Cylinder 1E74 626 1 ea Closer 5100 689 1 ea Kick Plate 194S 630 1 ea Wall Stop 232W 630 1 ea Smoke Seal 726S CHARCOAL

HDW SET 14

Door Numbers: 113A Each opening to receive:

1 ea Continuous Geared Hinge 780-224HD x ETW x RBCC 628 1 ea Continuous Geared Hinge 780-224HD x RBCC

1 ea Exit Device 8600LR x 24VDC 630 1 ea Exit Device 8600 630 1 ea Cylinder 1E74 626 2 ea Pulls H12J 630 2 ea Closers 5100 x HDS 689 2 ea Brackets 5100 x 5113 689 1 ea Threshold 413S 628 2 ea Door Sweeps 750SN 628 1 ea Power Supply PS-LR 600

Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final

DOOR HARDWARE 087100 - 22

1 ea Card Reader

Note: Meeting stile and Astragal provided by door manufacture.

Description of Operation:

Door normally closed and locked.

Upon proper credential validation active door latch bolt will retract and allow entry.

Doors will remain closed and locked during fire alarm activation or power failure.

Free egress at all times.

HDW SET 15

Door Numbers: 101A Each opening to receive:

1 ea Continuous Geared Hinge 780-224HD x RETW x RBCC 628 1 ea Continuous Geared Hinge 780-224HD x RBCC

1 ea Exit Device 8600LR x 24VDC 630 1 ea Exit Device 8600 630 1 ea Cylinder 1E74 626 2 ea Pulls H12J 630 1 ea Auto Operator 9531 689 1 ea Closer 5100 x HDS 689 1 ea Bracket 5110 x 5113 689 1 ea Threshold 413S 628 2 ea Door Sweeps 750SN 628 1 ea Power Supply PS-LR 600 1 ea Actuator 8310-856T 630 1 ea Card Reader

Note: Meeting stile and Astragal provided by door manufacture.

Description of Operation:

Doors are normally closed and locked.

Exterior actuator pad is inactive until proper credential validation.

Upon proper credential validation active door latch bolt will retract and allow entry. Entry is gained by pulling active door open manually or by pushing exterior actuator pad to open door automatically.

Pushing interior actuator pad will retract active door latch bolt and activate automatic operator to open door.

Doors will remain closed and locked during fire alarm activation or power failure. Actuator pads will be inactive during fire alarm or power failure.

Free egress at all times.

HDW SET 16

Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final

DOOR HARDWARE 087100 - 23

Door Numbers: 125A Each opening to receive:

3 ea Hinges BB1191 x 4-1/2” x 4-1/2” x NRP 630 1 ea Exit Device 4500 x RIM 626 1 ea Electric Strike 0161 x 12VDC x FSEC 626 1 ea Trim 45NL x ARC 626 1 ea Cylinder 1E74 626 1 ea Closer 5100 x HDS 689 1 ea Kick Plate 194S 630 1 ea Threshold 413S 628 1 ea Door Sweep 750SN 628 1 set Weatherstrip 881SN 628 1 ea Rain Drip 810S 628 1 ea Power Supply T1003 x 12VDC 1 ea Card Reader

Description of Operation:

Door is normally closed and locked.

Upon proper credential validation electric strike will release and allow the door to open.

Doors will remain closed and locked during power failure.

Free egress at all times.

HDW SET 17

Door Numbers: 125T Each opening to receive:

3 ea Hinges BB1191 x 4-1/2” x 4-1/2” x NRP 630 1 ea Exit Device 4500 x RIM 626 1 ea Trim 45NL x ARC 626 1 ea Cylinder 1E74 626 1 ea Closer 5100 x HDS 689 1 ea Kick Plate 194S 630 1 ea Threshold 413S 628 1 ea Door Sweep 750SN 628 1 set Weatherstrip 881SN 628 1 ea Rain Drip 810S 628

HDW SET 18

Door Numbers: 125H, 125J, 125K, 125M, 125N, 125P, 125Q, 125R, 126A Each opening to receive:

3 ea Hinges BB1279 x 4-1/2” x 4-1/2” x NRP 652 1 ea Exit Device 4500 x RIM 626 1 ea Trim 45CE x ARC 626 1 ea Cylinder 1E74 626

Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final

DOOR HARDWARE 087100 - 24

1 ea Closer 5100 x HDS 689 1 ea Kick Plate 194S 630 3 ea Silencers 307D GREY

HDW SET 19

Door Numbers: 115 Each opening to receive:

4 ea Hinges BB1279 x 4-1/2” x 4-1/2” x NRP 652 2 ea Hinges BB1279 x 4-1/2” x 4-1/2” x ETW 652 2 ea Exit Devices 4500 x SVR x EL x 24VDC 626 1 ea Trim 45CE x ARC 626 1 ea Cylinder 1E74 626 1 ea Auto Operator 9563 689 2 ea Armor Plate 194S 630 2 ea Wall Stops 232W 630 1 set Smoke Seal 726S CHARCOAL 1 set Astragal 802SB 628 1 ea Actuator 8310-856T 630 1 ea Power Supply 1406-04-AO 600

Description of Operation:

Doors are normally closed and latched.

Pushing interior actuator will retract latch bolts and activate automatic operators to open doors simultaneously. There is no exterior actuator.

Automatic operators work as manual door closers during power failure; actuator becomes inactive during power failure or fire alarm activation.

Free egress at all times.

HDW SET 20

Door Numbers: 126B Each opening to receive:

6 ea Hinges BB1191 x 4-1/2” x 4-1/2” x NRP 630 2 ea Exit Devices 4500 x SVR 626 1 ea Trim 45CE x ARC 626 1 ea Cylinder 1E74 626 2 ea Closers 5100 x HDS 689 2 ea Kick Plates 194S 630 1 ea Threshold 413S 628 2 ea Door Sweeps 750SN 628 1 set Weatherstrip 881SN 628 1 set Astragal 802SB 628 1 ea Rain Drip 810S 628

Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final

DOOR HARDWARE 087100 - 25

END OF SECTION 087100