F5W61608 USPFO Warehouse Ohio Army National Guard Rev. 0 Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final
TOILET COMPARTMENTS 102113 - 1
SECTION 102113 - TOILET COMPARTMENTS
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes:
1. Solid-polymer toilet compartments configured as toilet enclosures and urinal screens.
1.2 SUBMITTALS
A. Product Data: For each type of product indicated.
B. LEED Submittals:
1. Product Data for Credit MR 4.1: For products having recycled content, documentation indicating percentages by weight of postconsumer and preconsumer recycled content. Include statement indicating costs for each product having recycled content.
C. Shop Drawings: For toilet compartments. Include plans, elevations, sections, details, and attachments to other work.
D. Samples for each exposed product and for each color and texture specified.
E. Product certificates.
F. Maintenance data.
1.3 QUALITY ASSURANCE
A. Surface-Burning Characteristics: As determined by testing identical products according to ASTM E 84, or another standard acceptable to authorities having jurisdiction, by a qualified testing agency. Identify products with appropriate markings of applicable testing agency.
1. Flame-Spread Index: 25or less.
2. Smoke-Developed Index: 450 or less.
B. Regulatory Requirements: Comply with applicable provisions in the U.S. Architectural & Transportation Barriers Compliance Board's "Americans with Disabilities Act (ADA)
Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final
TOILET COMPARTMENTS 102113 - 2
and Architectural Barriers Act (ABA) Accessibility Guidelines for Buildings and Facilities" and ICC/ANSI A117.1 for toilet compartments designated as accessible.
PART 2 - PRODUCTS
2.1 MATERIALS
A. Steel Sheet: Commercial steel sheet for exposed applications; mill phosphatized and selected for smoothness.
1. Electrolytically Zinc Coated: ASTM A 879/A 879M, 01Z.
2. Hot-Dip Galvanized: ASTM A 653/A 653M, either hot-dip galvanized or galvannealed.
B. Zamac: ASTM B 86, commercial zinc-alloy die castings.
2.2 SOLID-POLYMER UNITS
A. Basis-of-Design Product: Subject to compliance with requirements, provide Santana Products, Inc. or comparable product by one of the following:
1. Accurate Partitions Corporation.
2. Bradley Corporation; Mills Partitions.
3. General Partitions Mfg. Corp.
4. Metpar Corp.
5. Bobrick
B. Toilet-Enclosure Style: Overhead braced.
C. Urinal-Screen Style: Wall hung .
D. Door, Panel, and Pilaster Construction: Solid, high-density polyethylene (HDPE) panel material, not less than 1 inch thick, seamless, with eased edges, and with homogenous color and pattern throughout thickness of material.
1. Integral Hinges: Configure doors and pilasters to receive integral hinges.
2. Heat-Sink Strip: Manufacturer's standard continuous, extruded-aluminum or stainless-steel strip fastened to exposed bottom edges of solid-polymer components to prevent burning.
a. Color and Pattern: As indicated on the color schedule.
E. Pilaster Shoes and Sleeves (Caps): Manufacturer's standard design; stainless steel.
F. Brackets (Fittings):
Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final
TOILET COMPARTMENTS 102113 - 3
1. Full-Height (Continuous) Type: Manufacturer's standard design; stainless steel.
2.3 ACCESSORIES
A. Hardware and Accessories: Manufacturer's standard design, heavy-duty operating hardware and accessories.
1. Material: Stainless steel.
2. Hinges: Manufacturer's standard continuous, cam type that swings to a closed or partially open position.
3. Latch and Keeper: Manufacturer's standard recessed latch unit designed for emergency access and with combination rubber-faced door strike and keeper.
Provide units that comply with regulatory requirements for accessibility at compartments designated as accessible.
4. Coat Hook: Manufacturer's standard combination hook and rubber-tipped bumper, sized to prevent in-swinging door from hitting compartment-mounted accessories.
5. Door Bumper: Manufacturer's standard rubber-tipped bumper at out-swinging doors.
6. Door Pull: Manufacturer's standard unit at out-swinging doors that complies with regulatory requirements for accessibility. Provide units on both sides of doors at compartments designated as accessible.
B. Overhead Bracing: Manufacturer's standard continuous, extruded-aluminum head rail with antigrip profile and in manufacturer's standard finish.
C. Anchorages and Fasteners: Manufacturer's standard exposed fasteners of stainless steel or chrome-plated steel or brass, finished to match the items they are securing, with theft-resistant-type heads. Provide sex-type bolts for through-bolt applications.
For concealed anchors, use stainless steel, hot-dip galvanized steel, or other rust-resistant, protective-coated steel.
2.4 FABRICATION
A. Overhead-Braced Units: Provide manufacturer's standard corrosion-resistant supports, leveling mechanism, and anchors at pilasters to suit floor conditions.
Provide shoes at pilasters to conceal supports and leveling mechanism.
B. Door Size and Swings: Unless otherwise indicated, provide 24-inch- wide, in-swinging doors for standard toilet compartments and 36-inch- wide, out-swinging doors with a minimum 32-inch- wide, clear opening for compartments designated as accessible.
Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final
TOILET COMPARTMENTS 102113 - 4
PART 3 - EXECUTION
3.1 INSTALLATION
A. General: Comply with manufacturer's written installation instructions. Install units rigid, straight, level, and plumb. Secure units in position with manufacturer's recommended anchoring devices.
B. Clearances: Maximum 1/2 inch between pilasters and panels; 1 inch between panels and walls.
C. Stirrup Brackets: Secure panels to walls and to pilasters with no fewer than three brackets attached at midpoint and near top and bottom of panel. Locate wall brackets so holes for wall anchors occur in masonry or tile joints. Align brackets at pilasters with brackets at walls.
3.2 ADJUSTING
A. Hardware Adjustment: Adjust and lubricate hardware according to hardware manufacturer's written instructions for proper operation. Set hinges on in-swinging doors to hold doors open approximately 30 degrees from closed position when unlatched. Set hinges on out-swinging doors to return doors to fully closed position.
END OF SECTION 102113