Amendment_0004_-_EP-101.pdf

PDF 776 KB Posted

Attached to
Renovate Building 252 for Logistical Readiness (LRS) at Pease ANGB, NH
Solicitation number
W912WJ19B0007
Issued by

About this file

Amendment 0004 - EP-101

View the file

Other files

Show all 29

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

E

F

G

D

C

B

A

15 14 13 12 11 10 9 8

CU

J 30 (1)

J

PP1A-17

48" AFF

PP1A-19

60" AFF

PP1A-3PP1A-5

PP1A-29PP1A-30

PP1A-32

PP1A-34

PP1A-1

PP1A-4

PP1A-6

PP1A-8

PP1A-10 PP1A-10

PP1A-10

PP1A-10

PP1A-16

PP1A-9

PP1A-9

PP1A-9

PP1A-9

PP1A-25

PP1A-25

PP1A-31

PP1A-31 PP1A-31

PP1A-31

PP1A-12

PP1A-12

PP1A-12

WP

WP

WP

PP1A-27

PP1A-27

PP1A-27

PP1A-27

PP1A-21

PP1A-21

PP1A-33

PP1A-13PP1A-13

PP1A-31

SECURE HOLD ROOM

MECHANICAL/

SPRINKLER

14A

ELECTRICAL

CONFERENCE

ATOC

AIR TRANSPORT. CHIEF

AIR TRANSPORT.

SUPERINTENDENT

27, 30, 31

FLEET

SERVICES

PALLET BUILD

ARRIVAL

CORRIDOR

QA

DOCUMENTATION

QUALITY CONTROL

EQUIPMENT STORAGE

LOAD PLANNING

TRAINING/TESTING

CORRIDOR

20, 21

MEN'S LOCKER ROOM

CORR.

CHAPLAIN

CHANGING

CHANGING

MOBILITY RECEPTION

40, 47

SUPPLY OFFICE & MOBILITY ADMIN

VESTIBULE

PASSENGER SERVICES

MEDIC

NON-SECURE HOLD ROOM

18, 19

WOMEN'S LOCKER ROOM

WEAPONS VAULT

TELECOM

EXISTING ELECTRICAL

ROOM

PP1A-27

TR-8

TR-2

UH

UH

EF

DH

DF

DF

(1)M (1)M

(1)M

(1)

(1)

(1)

DWH

(1)

(1)

PP1B-59,61

PP1B-44

LDP-2,4,6

LDP-27

LDP-29

PP1B-52

LDP-29

PP1B-44

MCB

PP1A PP1B

LDP MDP

TR

PP1A-21

60" AFF

PP1A-9

60" AFF

PP1A-15

60" AFF

PP1A-17

60" AFF

PP1A-15

60" AFF

PP1A-15

PP1A-21

60" AFF

PP1A-21

60" AFF

PP1A-33

PP1A-33

PP1A-33

PP1A-33

LDP-31,33,35

PP1A-37

PP1A-19

PP1A-19

PP1A-19

PP1A-19

PP1A-18

PP1A-17

PP1A-15

PP1A-15

PP1A-17

PP1A-15

PP1A-13

PP1A-13

PP1A-13

PP1A-35

PP1A-35

PP1A-35

PP1A-35

PP1A-31

PP1A-27

PP1A-27

PP1A-25

PP1A-25

PP1A-25 PP1A-25

PP1A-14

PP1A-14

PP1A-14

PP1A-14

PP1A-14

PP1A-14

PP1A-11

PP1A-11

PP1A-11

PP1A-35

PP1A-31

PP1A-35

PP1A-21 PP1A-21

PP1A-23

PP1A-23

PP1A-23

PP1A-23

PP1A-23

PP1A-23

PP1A-7

PP1A-9PP1A-9

CU

CU

J

PP1A-36

J

PP1A-38

J

PP1A-38J

PP1A-40

18A

M.RM

20A

JAN.

LDP-38,40,42

DWP

(1)

MDP-8,10

(1)

LDP-8,10,12

UH

UH

(1)M

PP1B-48

EF

UH

J

J

J

J

J

J

J

PP1A-36

PP1A-36

PP1A-38

PP1A-38

PP1A-40

PP1A-40

PP1A-40

LDP-32,34,36

M

PP1B-52

LDP-2,4,6

EF

(1)M

MDP-35

J

MCB

3 3 3

PP1A-15

TR-5,7

PP1A-12

J J

J

JJ

J J

J

LDP-37,39,41

LDP-37,39,41

LDP-37,39,41

LDP-37,39,41

LDP-37,39,41

6 LDP-37,39,41

LDP-37,39,41

LDP-37,39,41

TR-9

TR-11

TR-10

PB

PB

PBPB 88

JJ

EF

PP1A-26

PP1A-289

(1)

(1)M

(3R)

(3R)

PP1A-17

PP1A-12 PP1A-12

PP1A-12

PP1A-9

PP1A-21

PP1A-19

MDP-18

MDP-20,22

MDP-2

(1)

J

(TYP. 3)

UH

UH

(1)

MDP-6

(1)

MDP-4

SECURITY

SCREENING

12B

FAMILY

BATHROOM

12A

FAMILY

BATHROOM

FAMILY

BATHROOM

FAMILY

BATHROOM

FAMILY

BATHROOM

TR-1

PP1A-24

J

TR-4

PP1A-10

TR-6

0 4' 8' 16'

Scale: 1/8" = 1'-0"

S O

L I C

I T

A T

I O

N

N

O

F I L

N

A M

E

D W

N

B

Y

C K

D

B

Y

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F I

U M

B E

R

S I Z

E

S U

B M

I T

T E

D

B

Y

P L O

T

S

C A

L E

I S

S U

E

D

A T

E

D A

T E

M A

R K

D E

S C

R I P

T I O

N

C O

N T

R A

C T

O

SHEET

IDENTIFICATION

D A

T E

A P

P R

SHEET OF

US Army Corps of Engineers

U S

A

R M

Y

C

O R

P S

E

N G

I N

E E

R S

C O

N C

O R

D

M

A

N E

W

E

N G

L A

D

I S

T R

I C

T

A

Yo rk

Str ee t Po rtla nd

, M ai ne

7.5

.77 co lb yc oe ng ine er ing .c om

R E

N O

V A

T

B

U I L

D I N

G

F O

R

L

O G

I S

T I C

R

A

D I N

E S

S

S

Q U

A D

R O

N

P E

A S

E

A

I

T

I O

N A

L

G

U A

B

S

E

N

H

A N

S I

D

W

W J

B

I S

S U

C

N

S T

R U

C T

I O

N

B C

T

PLAN

NORTH

W E

S T

E R

N

P

A R

T

F

L O

W

A

N

EP-101

J L

H

H C

G

B C

T

E P

D

W G

J M

B

F I L

E

N

O

SCALE 1/8" = 1'-0"

WESTERN PART FLOOR POWER PLANA2

MA

TC

H

LIN

E

EP

-1

KEY PLAN

MA

TC

H

LIN

E

EP

-1

NOTES:

1. SEE E-001 FOR LEGEND, GENERAL NOTES

AND ABBREVIATIONS.

2. SEE MECHANICAL AND PLUMBING

DRAWINGS FOR EXACT EQUIPMENT

LOCATIONS.

3. SEE SHEET EY-101 FOR TELECOM ROOM

NOTES AND SCOPE.

KEYED NOTES:

PROVIDE (3) INFRARED HEATER CONTROLLERS WITH (3)

DISCONNECT SWITCHES CONNECTED TO (7) INFRARED

HEATERS CONTROLLING THREE ZONES. SEE MECHANICAL

DRAWINGS FOR ZONING AND CONTROL WIRING DETAILS.

POWER FOR OVERHEAD DOORS.

PROVIDE THOMAS & BETTS 842-SC OR EQUAL, COMBINATION

FLOORBOX FOR DATA/POWER/HDMI. TRENCH SLAB TO

PROVIDE FLOOR RECESS AT COUNTERS. SEE STRUCTURAL

DRAWINGS FOR DETAIL.

PROVIDE SPLICE BOX FOR NEW CONDUCTOR SPLICING TO

CURRENT EXISTING SERVICE CONDUCTORS.

PROVIDE 120V ELECTRIC FOR POWERED DOOR.

CONNECTIONS FOR VAV UNIT ELECTRIC REHEAT.

COORDINATE WITH MECHANICAL FOR EXACT UNIT LOCATION

PROVIDE UNDERGROUND ELECTRICAL FEEDERS TO

CONDENSING UNITS. ELECTRICAL FEEDERS TO PENETRATE

EXTERIOR SIDE OF BUILDING AND TRANSITION TO

UNDERGROUND FOR FINAL ROUTING AND CONNECTION TO

CONDENSING UNITS. SEE UNDERGROUND ELECTRICAL

FEEDERS DETAIL "A4" ON SHEET E-501.

PROVIDE PUSH PADS FOR POWERED AUTOMATIC DOOR

OPENER.

CONNECTIONS FOR FIRE ALARM CONTROL PANEL AND FIRE

ALARM SYSTEM. SEE FA-101 FOR PANEL LOCATIONS.

USE LOCAL RECEPTACLE AS POWER CONNECTION FOR

SECURITY SCREENING EQUIPMENT.

USE LOCAL RECEPTACLE AS POWER CONNECTION FOR

WATER COOLER.

USE LOCAL RECEPTACLE AS POWER CONNECTION FOR

VENDING UNIT.

USE LOCAL RECEPTACLE AS POWER CONNECTION FOR

WASHING MACHINE UNIT.

USE LOCAL RECEPTACLE AS POWER CONNECTION FOR

ELECTRIC DRYER UNIT.

PROVIDE RACK MOUNTED 30A TWISTLOCK RECEPTACLE FOR

TELECOM ROOM UPS. RECEPTACLE TO BE MOUNTED ON

SIDE OF RACK, AND CORD FED FROM A CEILING MOUNTED

JUNCTION BOX. UTILIZE A STRAIN RELIEF SLEEVE ON

CORDED CONNECTION.

CONNECTION FOR SPRINKLER BELL. SEE FP-101.

PROVIDE ADVANTOR SECURITY PANEL AND MOUNT TO

WALL. SEE EY-101 FOR EXACT LOCATION.

BUILDING PA SYSTEM CONTROL PANEL.

02/28/19

AutoCAD SHX Text

WP

AutoCAD SHX Text N

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text C

AutoCAD SHX Text I

AutoCAD SHX Text L

AutoCAD SHX Text

HEBERT

AutoCAD SHX Text No.

AutoCAD SHX Text 14371

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text M

AutoCAD SHX Text A

AutoCAD SHX Text I

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text L

AutoCAD SHX Text A

AutoCAD SHX Text O

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text P

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text G

AutoCAD SHX Text I

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text

JAMES LEO

Sheets and Views
EP-101

File details come from the government source that posted it.