SECTION 08 71 00
DOOR HARDWARE
02/16
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by the basic designation only.
ASTM INTERNATIONAL (ASTM)
ASTM E283 (2004; R 2012) Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen
BUILDERS HARDWARE MANUFACTURERS ASSOCIATION (BHMA)
ANSI/BHMA A156.1 (2013) Butts and Hinges
ANSI/BHMA A156.13 (2012) Mortise Locks & Latches Series 1000
ANSI/BHMA A156.16 (2013) Auxiliary Hardware
ANSI/BHMA A156.18 (2016) Materials and Finishes
ANSI/BHMA A156.2 (2011) Bored and Preassembled Locks and Latches
ANSI/BHMA A156.21 (2014) Thresholds
ANSI/BHMA A156.22 (2012) Door Gasketing and Edge Seal Systems
ANSI/BHMA A156.3 (2014) Exit Devices
ANSI/BHMA A156.36 (2010) Auxiliary Locks
ANSI/BHMA A156.4 (2013) Door Controls - Closers
ANSI/BHMA A156.5 (2014) Cylinder and Input Devices for Locks
ANSI/BHMA A156.6 (2015) Architectural Door Trim
ANSI/BHMA A156.7 (2014) Template Hinge Dimensions
ANSI/BHMA A156.8 (2015) Door Controls - Overhead Stops and Holders
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 101 (2015; ERTA 2015) Life Safety Code
NFPA 252 (2012) Standard Methods of Fire Tests of
SECTION 08 71 00 Page 1
Door Assemblies
NFPA 72 (2013) National Fire Alarm and Signaling Code
NFPA 80 (2016) Standard for Fire Doors and Other Opening Protectives
STEEL DOOR INSTITUTE (SDI/DOOR)
SDI/DOOR A250.8 (2003; R2008) Recommended Specifications for Standard Steel Doors and Frames
U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)
36 CFR 1191 Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines
UNDERWRITERS LABORATORIES (UL)
UL Bld Mat Dir (2012) Building Materials Directory
1.2 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government.
SD-02 Shop Drawings
Manufacturer's Detail Drawings; G , AE
Verification of Existing Conditions; G , AE
Hardware Schedule; G , AE
Keying System; G , AE
SD-03 Product Data
Hardware Items; G , AE
SD-08 Manufacturer's Instructions
Installation; G
SD-10 Operation and Maintenance Data
Hardware Schedule Items, Data Package 1; G, RO
SD-11 Closeout Submittals
Key Bitting; G, RO
SECTION 08 71 00 Page 2
1.3 SHOP DRAWINGS
Submit manufacturer's detail drawings indicating all hardware assembly components and interface with adjacent construction. Base shop drawings on verified field measurements and include verification of existing conditions.
1.4 PRODUCT DATA
Indicate fire-ratings at applicable components. Provide documentation of ABA/ADA accessibility compliance of applicable components, as required by 36 CFR 1191 Appendix D - Technical.
1.5 HARDWARE SCHEDULE
Prepare and submit hardware schedule in the following form:
Hardware Item
Quantity Size Reference Publi-cation Type No.
Finish Mfr Name and Catalog No.
Key Control Symbols
UL
Mark (If fire-rated and listed)
BHMA
Finish Desig-nation
In addition, submit hardware schedule data package 1 in accordance with Section 01 78 23 OPERATION AND MAINTENANCE DATA.
1.6 KEY BITTING CHART REQUIREMENTS
1.6.1 Requirements
Submit key bitting charts to the Contracting Officer prior to completion of the work. Include:
a. Complete listing of all keys (e.g. AA1 and AA2).
b. Complete listing of all key cuts (AA1-123456, AA2-123458).
c. Tabulation showing which key fits which door.
d. Copy of floor plan showing doors and door numbers.
e. Listing of 20 percent more key cuts than are presently required in each master system.
1.7 QUALITY ASSURANCE
1.7.1 Hardware Manufacturers and Modifications
Provide, as far as feasible, locks, hinges, and closers of one lock, hinge, or closer manufacturer's make. Modify hardware as necessary to provide features indicated or specified.
1.7.2 Key Shop Drawings Coordination Meeting
Prior to the submission of the key shop drawing, the Contracting Officer, SECTION 08 71 00 Page 3
Contractor, Door Hardware Subcontractor, using Activity and Base Locksmith must meet to discuss and coordinate key requirements for the facility.
1.8 DELIVERY, STORAGE, AND HANDLING
Deliver hardware in original individual containers, complete with necessary appurtenances including fasteners and instructions. Mark each individual container with item number as shown on hardware schedule.
Deliver permanent keys and removable cores to the Contracting Officer, either directly or by certified mail. Deliver construction master keys with the locks.
PART 2 PRODUCTS
2.1 TEMPLATE HARDWARE
Hardware applied to metal or to prefinished doors must be manufactured using a template. Provide templates to door and frame manufacturers in accordance with ANSI/BHMA A156.7 for template hinges. Coordinate hardware items to prevent interference with other hardware.
2.2 HARDWARE FOR FIRE DOORS AND EXIT DOORS
Provide all hardware necessary to meet the requirements of NFPA 72 for door alarms, NFPA 80 for fire doors, NFPA 101 for exit doors, NFPA 252 for fire tests of door assemblies, ABA/ADA accessibility requirements, and all other requirements indicated, even if such hardware is not specifically mentioned in paragraph HARDWARE SCHEDULE. Provide Underwriters Laboratories, Inc. labels for such hardware in accordance with UL Bld Mat Dir or equivalent labels in accordance with another testing laboratory approved in writing by the Contracting Officer.
2.3 HARDWARE ITEMS
Clearly and permanently mark with the manufacturer's name or trademark, hinges, locks, latches, exit devices, bolts and closers where the identifying mark is visible after the item is installed. For closers with covers, the name or trademark may be beneath the cover.
2.3.1 Hinges
Provide in accordance with ANSI/BHMA A156.1 . Provide hinges that are 4-1/2 by 4-1/2 inch unless otherwise indicated. Construct loose pin hinges for interior doors and reverse-bevel exterior doors so that pins are non-removable when door is closed. Other anti-friction bearing hinges may be provided in lieu of ball bearing hinges.
2.3.2 Locks and Latches
2.3.2.1 Mortise Locks and Latches
Provide in accordance with ANSI/BHMA A156.13 , Series 1000, Operational Grade 1, Security Grade 2. Provide mortise locks with escutcheons not less than 7 by 2-1/4 inch with a bushing at least 1/4 inch long. Cut escutcheons to fit cylinders and provide trim items with straight, beveled, or smoothly rounded sides, corners, and edges. Provide levers and roses of mortise locks with screwless shanks and no exposed screws.
SECTION 08 71 00 Page 4
2.3.2.2 Bored Locks and Latches
Provide in accordance with ANSI/BHMA A156.2 , Series 4000, Grade 1.
2.3.2.3 Auxiliary Locks
Provide in accordance with ANSI/BHMA A156.36 , Grade 1.
2.3.3 Exit Devices
Provide in accordance with ANSI/BHMA A156.3 , Grade 1. Provide adjustable strikes for rim type and vertical rod devices. Provide open back strikes for pairs of doors with mortise and vertical rod devices. Provide touch bars in lieu of conventional crossbars and arms. Provide escutcheons not less than 7 by 2-1/4 inch.
2.3.4 Cylinders and Cores
Provide cylinders for new locks, including locks provided under other sections of this specification. Provide fully compatible cylinders of Grade 1 products from products of one manufacturer with interchangeable cores that are removable by a special control key. Factory set the cores with seven pin tumblers using the A4 system and F keyway. Submit a core code sheet with the cores. Provide master keyed cores in one system for this project. Provide construction interchangeable cores.
2.3.5 Keying System
Provide sub-master keying system for the building, and keyed to the existing removable core master and grand master keying systems. The Contracting Officer will provide keying information. Key equipment spaces and mechanical rooms separately from the building systems, and key alike to the existing master and grand master systems for these doors.
2.3.6 Lock Trim
Provide cast, forged, or heavy wrought construction and commercial plain design for lock trim.
2.3.6.1 Lever Handles
Provide lever handles . Provide in accordance with ANSI/BHMA A156.3 for mortise locks of lever handles for exit devices. Provide lever handle locks with a breakaway feature (such as a weakened spindle or a shear key) to prevent irreparable damage to the lock when force in excess of that specified in ANSI/BHMA A156.13 is applied to the lever handle. Provide lever handles return to within 1/2 inch of the door face.
2.3.6.2 Texture
Provide knurled or abrasive coated knobs or lever handles for doors which are accessible to blind persons and which lead to dangerous areas.
2.3.7 Keys
Provide one file key, one duplicate key, and one working key for each key change and for each master and grand master keying system. Provide one additional working key for each lock of each keyed-alike group.
Providezero great grand master keys, all construction master keys, and
SECTION 08 71 00 Page 5 zero control keys for removable cores. Provide a quantity of key blanks equal to 20 percent of the total number of file keys. Stamp each key with appropriate key control symbol and "U.S. property - do not duplicate." Do not place room number on keys building and key number stamped on key only, the Government will coordinate directly with best after the order is authorized.
2.3.8 Closers
Provide in accordance with ANSI/BHMA A156.4 , Series C02000, Grade 1, with PT 4C. Provide with brackets, arms, mounting devices, fasteners, full size covers, except at storefront mounting, and other features necessary for the particular application. Size closers in accordance with manufacturer's printed recommendations, or provide multi-size closers, Sizes 1 through 6, and list sizes in the Hardware Schedule. Provide manufacturer's 10 year warranty.
2.3.8.1 Identification Marking
Engrave each closer with manufacturer's name or trademark, date of manufacture, and manufacturer's size designation in locations that will be visible after installation.
2.3.9 Overhead Holders
Provide in accordance with ANSI/BHMA A156.8 .
2.3.10 Door Protection Plates
Provide in accordance with ANSI/BHMA A156.6 .
2.3.10.1 Sizes of Armorand Kick Plates
2 inch less than door width for single doors; 1 inch less than door width for pairs of doors. Provide 10 inch kick plates for flush doors. Provide a minimum 48 inch armor plates for flush doors , except 16 inch high armor plates on fire doors.
2.3.10.2 Edge Guards
Stainless steel, of same height as armor plates. Apply to meeting stiles.
2.3.11 Door Stops and Silencers
Provide in accordance with ANSI/BHMA A156.16 . Silencers Type L03011.
Provide three silencers for each single door, two for each pair.
2.3.12 Thresholds
Provide in accordance with ANSI/BHMA A156.21 . Use J35100, with vinyl or silicone rubber insert in face of stop, for exterior doors opening out, unless specified otherwise.
2.3.13 Weatherstripping Gasketing
Provide in accordance with ANSI/BHMA A156.22 . Provide the type and function designation where specified in paragraph HARDWARE SCHEDULE.
Provide a set to include head and jamb seals, sweep strips, and, for pairs of doors, astragals. Air leakage of weatherstripped doors not to exceed
SECTION 08 71 00 Page 6
0.5 cubic feet per minute of air per square foot of door area when tested in accordance with ASTM E283. Provide weatherstripping with one of the following:
2.3.13.1 Extruded Aluminum Retainers
Extruded aluminum retainers not less than 0.050 inch wall thickness with vinyl, neoprene, silicone rubber, or polyurethane inserts. Provide clear (natural) anodized aluminum.
2.3.13.2 Interlocking Type
Zinc or bronze not less than 0.018 inch thick.
2.3.13.3 Spring Tension Type
Spring bronze or stainless steel not less than 0.008 inch thick.
2.3.14 Soundproofing Gasketing
Provide in accordance with ANSI/BHMA A156.22 . Provide adjustable doorstops at heads,jambs and automatic door bottoms in accordance with the hardware set, of extruded aluminum, clear (natural) anodized, surface applied, with vinyl fin seals between plunger and housing. Provide doorstops with solid neoprene tube, silicone rubber, or closed cell sponge gasket. Provide door bottoms with adjustable operating rod and silicone rubber or closed cell sponge neoprene gasket. Provide doorstops that are mitered at corners. Provide type and function designation where specified in paragraph HARDWARE SETS.
2.3.15 Rain Drips
Provide in accordance with ANSI/BHMA A156.22 . Provide extruded aluminum rain drips, not less than 0.08 inch thick, clear anodized finish. Provide rain drips with a 4 inch overlap on each side of each exterior door that is not protected by an awning, roof, eave or other horizontal projection.
Set drips in sealant and fasten with stainless steel screws.
2.3.15.1 Door Rain Drips
Approximately 1-1/2 inch high by 5/8 inch projection. Align bottom with bottom edge of door.
2.3.15.2 Overhead Rain Drips
Approximately 1-1/2 inch high by 2-1/2 inch projection. Align bottom with door frame rabbet.
2.3.16 Auxiliary Hardware (Other than locks)
Provide in accordance with ANSI/BHMA A156.16 , Grade 1.
2.3.17 Special Tools
Provide special tools, such as spanner and socket wrenches and dogging keys, as required to service and adjust hardware items.
SECTION 08 71 00 Page 7
2.4 FASTENERS
Provide fasteners of type, quality, size, and quantity appropriate to the specific application. Fastener finish to match hardware. Provide stainless steel or nonferrous metal fasteners in locations exposed to weather. Verify metals in contact with one another are compatible and will avoid galvanic corrosion when exposed to weather.
2.5 FINISHES
Provide in accordance with ANSI/BHMA A156.18 . Provide hardware in BHMA 630 finish (satin stainless steel), unless specified otherwise. Provide items not manufactured in stainless steel in BHMA 626 finish (satin chromium plated) over brass or bronze, except aluminum paint finish for surface door closers, and except BHMA 652 finish (satin chromium plated) for steel hinges. Provide hinges for exterior doors in stainless steel with BHMA 630 finish or chromium plated brass or bronze with BHMA 626 finish. Furnish exit devices in BHMA 626 finish in lieu of BHMA 630 finish except where BHMA 630 is specified under paragraph HARDWARE SETS.
Match exposed parts of concealed closers to lock and door trim. Match hardware finish for aluminum doors to the doors.
2.6 KEY CABINET AND CONTROL SYSTEM
Provide in accordance with ANSI/BHMA A156.5 , . Type required to yield a capacity (number of hooks) 50 percent greater than the number of key changes used for door locks.
PART 3 EXECUTION
3.1 INSTALLATION
Provide hardware in accordance with manufacturers' printed installation instructions. Fasten hardware to wood surfaces with full-threaded wood screws or sheet metal screws. Provide machine screws set in expansion shields for fastening hardware to solid concrete and masonry surfaces.
Provide toggle bolts where required for fastening to hollow core construction. Provide through bolts where necessary for satisfactory installation.
3.1.1 Weatherstripping Installation
Provide full contact, weathertight seals that allow operation of doors without binding the weatherstripping.
3.1.1.1 Interlocking Type Weatherstripping
Provide interlocking, self adjusting type on heads and jambs and flexible hook type at sills. Nail weatherstripping to door 1 inch on center and to heads and jambs at 4 inch on center.
3.1.1.2 Spring Tension Type Weatherstripping
Provide spring tension type on heads and jambs. Provide bronze nails with bronze. Provide stainless steel nails with stainless steel. Space nails not more than 1-1/2 inch on center.
SECTION 08 71 00 Page 8
3.1.2 Soundproofing Installation
Provide as specified for stop applied weatherstripping.
3.1.3 Threshold Installation
Extend thresholds the full width of the opening and notch end for jamb stops. Set thresholds in a full bed of sealant and anchor to floor with cadmium-plated, countersunk, steel screws in expansion sleeves.
3.2 FIRE DOORS AND EXIT DOORS
Provide hardware in accordance with NFPA 72 for door alarms, NFPA 80 for fire doors, NFPA 101 for exit doors, and NFPA 252 for fire tests of door assemblies.
3.3 HARDWARE LOCATIONS
Provide in accordance with SDI/DOOR A250.8 , unless indicated or specified otherwise.
a. Kick and Armor Plates: Push side of single-acting doors. Both sides of double-acting doors.
3.4 KEY CABINET AND CONTROL SYSTEM
Locate where directed. Tag one set of file keys and one set of duplicate keys. Place other keys in appropriately marked envelopes, or tag each key. Provide complete instructions for setup and use of key control system. On tags and envelopes, indicate door and room numbers or master or grand master key.
3.5 FIELD QUALITY CONTROL
After installation, protect hardware from paint, stains, blemishes, and other damage until acceptance of work. Submit notice of testing 15 days before scheduled, so that testing can be witnessed by the Contracting Officer. Adjust hinges, locks, latches, bolts, holders, closers, and other items to operate properly. Demonstrate that permanent keys operate respective locks, and give keys to the Contracting Officer. Correct, repair, and finish, errors in cutting and fitting and damage to adjoining work.
3.6 HARDWARE SETS
SECTION 08 71 00 Page 9
Provide hardware for all doors except aluminum doors and overhead coiling doors under this section See door schedule for locations of each set noted below. Coordinate all hardware sets with electrical as required.
Set No. 1 3 Hinges 1 Closer 1 Lockset (Storage Function) 1 Kick Plate 3 Silences
Set No. 2 3 Hinges 1 Closer 1 Lockset (Passage Function) Wall stop/bumper 1 Kick Plate 3 Silencers
Set No. 3 3 Hinges 1 Closer 1 Lockset (Office Function) 1 Kick Plate 1 Wall stop 3 Silencers
Set No. 4 3 Hinges 1 Closer 1 Lockset (Office Function) 1 Kickplate 1 Wall stop 3 Silencers
Set No. 5 3 Hinges 1 Closer with ma gneti nual c hold open 1 Lockset (Storeroom Function) 1 Kick Plate 1 Threshold 1 Set Weather Stripping 1 Aut hoomatic Door Bottom 3 Silencers
Set No. 6 3 Hinges 1 Closer with ma gnetic nual hold open 1 Set Push/Pull Wall stop/bumper 1 Kick Plate 3 Silencers
Set No. 7 3 Hinges 1 Closer 1 Lockset (Classroom Function) 1 Kick Plate
SECTION 08 71 00 Page 10
1 Threshold 1 Set Weather Stripping 1 Authomatic Door Bottom 3 Silencers
Set No. 8 3 Hinges 1 Closer with ma gnetic nual hold open 1 Exit Device with keyed entry to exterior side 1 Kick Plate 3 Silencers
Set No. 9 6 Hinges 1 Closer with ma gnetic nual hold open 1 Lockset (Storage Function) 4 Kick Plate 6 Silencers 1 Threshold (6' long) 2 Sets Weatherstripping 1 Astragal 2 Automatic Door Bottoms 1 Set Edge Bolt Latches (top and bottom)on non-active door 1 Wall Stop 1 ABA Push Pad
Set No. 10 6 Hinges 1 Closer 1 Lockset (Storage Function) 4 Kick Plate 6 Silencers 1 Astragal 1 Set Edge Bolt Latches (top and bottom)on non-active door
Set No. 11 6 Hinges 2 Closer with ma gnetic nual hold open 2 Exit Device with vertical rods 1 Coordinator 2 Kick Plate 6 Silencers
Set No. 12 6 Hinges 2 Closer with ma gnetic nual hold open 1 Lockset (Office/Classroom Function) 2 Wall stop 2 Kick Plate 6 Silencers 1 Astragal 1 Set Edge Bolt Latches (top and bottom)on non-active door
Set No. 13 6 Hinges 2 Closer with ma gnetic nual hold open 1 Lockset (Entry Function) 1 Exit device 1 Coordinator
SECTION 08 71 00 Page 11
2 Kick Plate 6 Silencers 1 Knockdown Astragal 1 ABA Push Pad - (right leaf entry/right leaf exit)
Set No. 14 6 Hinges 2 Closer with ma gnetic nual hold open 4 Push/Pull Plate(s) 4 Kick Plate 6 Silencers
Set No. 15 3 Hinges 1 Closer with magnetic hold open 1 Lockset (Entry Function) 1 Exit device 2 Kick Plate(s) 3 Silencers 1 ABA Push Pad Not Used
Set No. 16 3 Hinges 1 Closer with ma gnetic nual hold open 1 Lockset (Entry Function) 1 Exit device 2 Kick Plate 3 Silencers
Set No. 17 All overhead doors to have slidelock to override button.
Set No. 18 All wire mesh partitions to have gate latch with padlock.
Set No. 19 Vault door to have XO9 with key and secondary keyed lock.
-- End of Section --
SECTION 08 71 00 Page 12