Amendment_0004_-_A-602.pdf
PDF 398 KB Posted
- Solicitation number
- W912WJ19B0007
About this file
Amendment 0004 - A-602
View the file
Other files
Show all 29
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S O
L I C
I T
A T
I O
N
N
O
F I L E
N
A M
E
D W
N
B
Y
C K
D
B
Y
D E
S I G
N E
D
B
Y
D E
S C
R I P
T I O
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F I
U M
B E
R
S I Z
E
S U
B M
I T
T E
D
B
Y
P L O
T
S
C A
L E
I S
S U
E
D
A T
E
D A
T E
M A
R K
D E
S C
R I P
T I O
N
C O
N T
R A
C T
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF
US Army Corps of Engineers
U S
A
R M
Y
C
O R
P
F
E
N G
I N
E E
R S
C O
N C
O R
D
M
A
N E
W
E
N G
L A
D
I S
T R
I C
T
A
Yo rk
Str ee t Po rtla nd
, M ai ne
7.5
.77 co lb yc oe ng ine er ing .c om
R E
N O
V A
T
B
U I L
D I N
G
F O
R
L
O G
I S
T I C
R
A
D I N
E S
S
S
Q U
A D
R O
N
P E
A S
E
A
I
T
I O
N A
L
G
U A
B
S
E
N
H
A N
S I
D
W
W J
B
I S
S U
F
N
S T
R U
C T
I O
N
B C
T
DOOR SCHEDULE
ID LOCATION TYPE HEIGHT WIDTH THICKNESS UNDERCUT DOOR MAT'L DOOR FINISH GLAZING FRAME MAT'L FRAME FINISH FRAME TYPE DETAILS HDWR SET CARD
READER
ALARM ELECTRIFIED, SEE ELECTRICAL REMARKS
101A VESTIBULE B 7'-0" (2) 3'-0" 0'-1 3/4" --- INSUL H MTL PREFINISHED TEMPERED INSUL H MTL PREFINISHED 4 B1, B3, A2/A-603 #13 MONITORED SEE ELECTRICAL INTEGRAL SIDELIGHTS 101B VESTIBULE B 7'-0" (2) 3'-0" 0'-1 3/4" --- INSUL H MTL PREFINISHED TEMPERED INSUL H MTL PREFINISHED 4 D1,D2,A2/A-603 #14 --- INTEGRAL SIDELIGHTS 103A MOBILITY RECEPTION A 7'-0" (2) 3'-0" 1-3/4" --- INSUL H MTL PREFINISHED --- INSUL H MTL PREFINISHED 1 D1,D2,A2/A-603 # 9 SEE ELECTRICAL 103B MOBILITY RECEPTION A 7'-0" (2) 3'-0" 1-3/4" --- INSUL H MTL PREFINISHED --- INSUL H MTL PREFINISHED 1 D1,D2,A2/A-603 # 9 SEE ELECTRICAL 104 CHANGING A 7'-0" 3'-0" 1-3/4" 1/2" H MTL PREFINISHED --- H MTL PREFINISHED 1 D1,D2,A2/A-603 # 3 --- 105 CHANGING A 7'-0" 3'-0" 1-3/4" 1/2" H MTL PREFINISHED --- H MTL PREFINISHED 1 D1,D2,A2/A-603 # 3 ---
106A NON-SECURE HOLD ROOM A 7'-0" (2) 3'-0" 1-3/4" --- INSUL H MTL PREFINISHED --- INSUL H MTL PREFINISHED 1 B1, B3, A2/A-603 # 11 MONITORED SEE ELECTRICAL 106B NON-SECURE HOLD ROOM A 7'-0" (2) 3'-0" 1-3/4" --- H MTL PREFINISHED --- H MTL PREFINISHED 1 D1,D2,A2/A-603 # 12 106C NON-SECURE HOLD ROOM A 7'-0" 3'-0" 1-3/4" --- INSUL H MTL PREFINISHED --- INSUL H MTL PREFINISHED 1 B1, B3, A2/A-603 # 8 MONITORED SEE ELECTRICAL 107 FAMILY BATHROOM A 7'-0" 3'-0" 1-3/4" 1/2" H MTL PREFINISHED --- H MTL PREFINISHED 1 D1,D2,A2/A-603 # 3 --- 108 FAMILY BATHROOM A 7'-0" 3'-0" 1-3/4" 1/2" H MTL PREFINISHED --- H MTL PREFINISHED 1 D1,D2,A2/A-603 # 3 --- 111 FAMILY BATHROOM A 7'-0" 3'-0" 1-3/4" 1/2" H MTL PREFINISHED --- H MTL PREFINISHED 1 B1, B3, A2/A-603 # 3 ---
112A FAMILY BATHROOM A 7'-0" 3'-0" 1-3/4" 1/2" H MTL PREFINISHED --- H MTL PREFINISHED 1 D1,D2,A2/A-603 # 3 --- 112B FAMILY BATHROOM A 7'-0" 3'-0" 1-3/4" 1/2" H MTL PREFINISHED --- H MTL PREFINISHED 1 D1,D2,A2/A-603 # 3 --- 113A SECURE HOLD ROOM B 7'-0" 12'-8" 0'-1 3/4" --- INSUL H MTL PREFINISHED TEMPERED INSUL H MTL PREFINISHED 4 B1, B3, A2/A-603 #13 MONITORED SEE ELECTRICAL INTEGRAL SIDELIGHTS 113B SECURE HOLD ROOM A 7'-0" 3'-0" 1-3/4" --- INSUL H MTL PREFINISHED --- INSUL H MTL PREFINISHED 1 B1, B3, A2/A-603 # 8 MONITORED SEE ELECTRICAL 114A ELECTRICAL A 7'-0" 3'-0" 1-3/4" --- INSUL H MTL PREFINISHED --- INSUL H MTL PREFINISHED 1 B1, B3, A2/A-603 # 5 MONITORED SEE ELECTRICAL 115 MECHANICAL/SPRINKLER A 7'-0" 3'-0" 1-3/4" --- INSUL H MTL PREFINISHED --- INSUL H MTL PREFINISHED 1 B1, B3, A2/A-603 # 5 MONITORED SEE ELECTRICAL
116A ARRIVAL PATH B 7'-0" 12'-8" 0'-1 3/4" --- INSUL H MTL PREFINISHED TEMPERED INSUL H MTL PREFINISHED 4 B1, B3, A2/A-603 #13 YES MONITORED SEE ELECTRICAL INTEGRAL SIDELIGHTS 116B ARRIVAL PATH A 7'-0" 3'-0" 1-3/4" --- INSUL H MTL PREFINISHED --- INSUL H MTL PREFINISHED 3 D1,D2,A2/A-603 #14 YES --- INSULATED DOOR SYSTEM WITH INTEGRAL SIDELIGHT 117A CORRIDOR A 7'-0" 3'-0" 1-3/4" --- INSUL H MTL PREFINISHED --- INSUL H MTL PREFINISHED 1 D1,D2,A2/A-603 #3 --- PERSONNEL DOOR WITH INTEGRAL SIDELIGHT 117B CORRIDOR A 7'-0" 3'-0" 1-3/4" --- H MTL PREFINISHED --- H MTL PREFINISHED 1 D1,D2,A2/A-603 #3 YES LOCAL ELECTRIC LATCH PERSONNEL DOOR WITH INTEGRAL SIDELIGHT 118A MOTHERS ROOM A 7'-0" 3'-0" 1-3/4" 1/2" H MTL PREFINISHED --- H MTL PREFINISHED 1 D1,D2,A2/A-603 # 3 --- 120A JANITOR A 7'-0" 3'-0" 1-3/4" 1/2" H MTL PREFINISHED --- H MTL PREFINISHED 1 D1,D2,A2/A-603 # 1 --- 122A CONFERENCE A 7'-0" 3'-0" 1-3/4" --- H MTL PREFINISHED --- H MTL PREFINISHED 1 D1,D2,A2/A-603 #6 YES LOCAL 122B CONFERENCE A 7'-0" 3'-0" 1-3/4" --- INSUL H MTL PREFINISHED --- INSUL H MTL PREFINISHED 1 B1, B3, A2/A-603 #16 YES MONITORED SEE ELECTRICAL 123 DOCUMENT QUALITY CONTROL A 7'-0" 3'-0" 1-3/4" --- H MTL PREFINISHED --- H MTL PREFINISHED 3 D1,D2,A2/A-603 #8 PERSONNEL DOOR WITH INTEGRAL SIDELIGHT 124 QA A 7'-0" 3'-0" 1-3/4" --- H MTL PREFINISHED --- H MTL PREFINISHED 3 D1,D2,A2/A-603 # 4 PERSONNEL DOOR WITH INTEGRAL SIDELIGHT 125 LOAD PLANNING A 7'-0" 3'-0" 1-3/4" --- H MTL PREFINISHED --- H MTL PREFINISHED 3 D1,D2,A2/A-603 # 4 PERSONNEL DOOR WITH INTEGRAL SIDELIGHT 126 TRAINING TESTING A 7'-0" 3'-0" 1-3/4" --- H MTL PREFINISHED --- H MTL PREFINISHED 3 D1,D2,A2/A-603 # 4 PERSONNEL DOOR WITH INTEGRAL SIDELIGHT
127A FLEET SERVICES A 7'-0" 3'-0" 1-3/4" --- INSUL H MTL PREFINISHED --- INSUL H MTL PREFINISHED 1 D1,D2,A2/A-603 #16 YES LOCAL 127B FLEET SERVICES A 7'-0" 3'-0" 1-3/4" --- H MTL PREFINISHED --- H MTL PREFINISHED 3 D1,D2,A2/A-603 #3 PERSONNEL DOOR WITH INTEGRAL SIDELIGHT 129 AIR TRANSPORT. CHIEF A 7'-0" 3'-0" 1-3/4" --- H MTL PREFINISHED --- H MTL PREFINISHED 3 D1,D2,A2/A-603 # 4 PERSONNEL DOOR WITH INTEGRAL SIDELIGHT 130 AIR TRANSPORT. SUPERINTENDENT A 7'-0" 3'-0" 1-3/4" --- H MTL PREFINISHED --- H MTL PREFINISHED 3 D1,D2,A2/A-603 # 4 PERSONNEL DOOR WITH INTEGRAL SIDELIGHT
133A PALLET BUILD A 7'-0" 3'-0" 1-3/4" --- INSUL H MTL PREFINISHED --- INSUL H MTL PREFINISHED 1 B1, B3, A2/A-603 #16 YES MONITORED SEE ELECTRICAL 134A MOBILITY STORAGE B 7'-0" (2) 3'-0" 1-3/4" --- INSUL H MTL PREFINISHED --- INSUL H MTL PREFINISHED 4 B1, B3, A2/A-603 #16 MONITORED SEE ELECTRICAL 134C MOBILITY STORAGE C --- 12'-8" 1-3/4" --- INSUL H MTL GALV STEEL --- STEEL PER MANUFACTURER POWDER COAT --- A3,A4/A-603 --- MONITORED SEE ELECTRICAL EXISTING TO REMAIN 135A AERIAL DELIVERY STORAGE AREA C 16'-0" 16'-4" 0-3/4" --- INSUL H MTL GALV STEEL --- STEEL PER MANUFACTURER POWDER COAT --- A3,A4/A-603 #17 MONITORED SEE ELECTRICAL OVERHEAD COILING GARAGE DOOR / OVERHEAD OPENER 135B AERIAL DELIVERY STORAGE AREA A 7'-0" 3'-0" 1-3/4" --- INSUL H MTL PREFINISHED --- INSUL H MTL PREFINISHED 1 B1, B3, A2/A-603 # 8 MONITORED SEE ELECTRICAL 137 EXISTING ELECTRICAL ROOM --- --- --- --- --- --- --- --- --- --- --- --- --- MONITORED SEE ELECTRICAL EXISTING TO REMAIN
136A ATGL VEHICLE STORAGE C 16'-0" 20'-4" 0-3/4" --- INSUL H MTL GALV STEEL --- STEEL PER MANUFACTURER POWDER COAT --- A3,A4/A-603 #17 MONITORED SEE ELECTRICAL OVERHEAD COILING GARAGE DOOR / OVERHEAD OPENER 136B ATGL VEHICLE STORAGE C 16'-0" 20'-4" 0-3/4" --- INSUL H MTL GALV STEEL --- STEEL PER MANUFACTURER POWDER COAT --- A3,A4/A-603 #17 MONITORED SEE ELECTRICAL OVERHEAD COILING GARAGE DOOR / OVERHEAD OPENER 136C ATGL VEHICLE STORAGE A 7'-0" 3'-0" 1-3/4" --- INSUL H MTL PREFINISHED --- INSUL H MTL PREFINISHED 1 B1, B3, A2/A-603 # 5 YES MONITORED SEE ELECTRICAL 136D ATGL VEHICLE STORAGE A 7'-0" 3'-0" 1-3/4" --- INSUL H MTL PREFINISHED --- INSUL H MTL PREFINISHED 1 D1,D2,A2/A-603 # 2 138 CAGED SECURITY REQ. CARGO D 8'-0" (2) 4'-0" --- --- STEEL WIRE PREFINISHED --- STEEL PER MANUFACTURER PREFINISHED --- PER MANUFACTURER #18 ASSEMBLED WIRE MESH PARTITION AND DOOR SYSTEM
139A EQUIPMENT STORAGE A 7'-0" 3'-0" 1-3/4" --- INSUL H MTL PREFINISHED --- INSUL H MTL PREFINISHED 1 D1,D2,A2/A-603 #5 139B EQUIPMENT STORAGE A 7'-0" 3'-0" 1-3/4" --- H MTL PREFINISHED --- H MTL PREFINISHED 1 D1,D2,A2/A-603 # 7 141 CHAPLAIN A 7'-0" 3'-0" 1-3/4" --- H MTL PREFINISHED --- H MTL PREFINISHED 1 D1,D2,A2/A-603 # 4 142 MEDIC A 7'-0" 3'-0" 1-3/4" --- H MTL PREFINISHED --- H MTL PREFINISHED 1 D1,D2,A2/A-603 # 4 143 VAULT E 7'-0" (2) 44" PER MANUFACTUER --- PER MANUFACTURER PREFINISHED --- PER MANUFACTURER PREFINISHED 5 PER MANUFACTURER #19 YES MONITORED SEE ELECTRICAL VAULT DOOR WITH DAY GATE / KEY PAD AND KEYED LOCK
145A ATGL STORAGE C 16'-0" 12'-4" 3/4" --- INSUL H MTL GALV STEEL --- STEEL PER MANUFACTURER POWDER COAT --- A3,A4/A-603 #17 MONITORED SEE ELECTRICAL OVERHEAD COILING GARAGE DOOR / OVERHEAD OPENER 145B ATGL STORAGE A 7'-0" 3'-0" 1-3/4" --- INSUL H MTL PREFINISHED --- INSUL H MTL PREFINISHED 1 D1,D2,A2/A-603 #4 145C ATGL STORAGE A 7'-0" 3'-0" 1-3/4" --- INSUL H MTL PREFINISHED --- INSUL H MTL PREFINISHED 1 B1, B3, A2/A-603 # 8 MONITORED SEE ELECTRICAL 146A ATGL CLEANING/SERVICING C 16-0" 12'-4" 3/4" --- INSUL H MTL GALV STEEL --- STEEL PER MANUFACTURER POWDER COAT 3 A3,A4/A-603 #17 MONITORED SEE ELECTRICAL OVERHEAD OPENER 146B ATGL CLEANING/SERVICING A 7'-0" 3'-0" 1-3/4" --- INSUL H MTL PREFINISHED --- INSUL H MTL PREFINISHED 1 D1,D2,A2/A-603 #4 146C ATGL CLEANING/SERVICING A 7'-0" 3'-0" 1-3/4" --- INSUL H MTL PREFINISHED --- INSUL H MTL PREFINISHED 1 B1, B3, A2/A-603 #16 YES MONITORED SEE ELECTRICAL 147A SUPPLY OFFICE & MOBILITY ADMIN A 7'-0" 3'-0" 1-3/4" --- H MTL PREFINISHED --- H MTL PREFINISHED 1 D1,D2,A2/A-603 # 4 147B SUPPLY OFFICE & MOBILITY ADMIN A 7'-0" 3'-0" 1-3/4" --- H MTL PREFINISHED --- H MTL PREFINISHED 1 D1,D2,A2/A-603 # 4 147C SUPPLY OFFICE & MOBILITY ADMIN A 7'-0" 3'-0" 1-3/4" --- INSUL H MTL PREFINISHED --- INSUL H MTL PREFINISHED 1 D1,D2,A2/A-603 # 4
147D SUPPLY OFFICE & MOBILITY ADMIN A SEE DETAIL
A3/A-504 5'-0" 1-3/4" --- PREFINISHED --- PREFINISHED 1 A3/A-504 #17 OVERHEAD COILING COUNTER DOOR
148 TELECOM A 7'-0" 3'-0" 1-3/4" --- INSUL H MTL PREFINISHED --- INSUL H MTL PREFINISHED 1 D1,D2,A2/A-603 # 5
D O
H
E D
U L E
A-602
B L
B
C R
D
B C
T
A
D
W G
R T
M
E6EPGMEC
Polygon
E6EPGMEC
Polygonal Line
E6EPGMEC
Typewritten Text
File details come from the government source that posted it.