METAL DECK, SEE STRUCTURAL

METAL JOIST, SEE STRUCTURAL

STEEL BEAM, SEE STRUCTURAL

ACOUSTICAL CEILING SYSTEM

3 5/8" METAL STUD WALL

3" BATT INSULATION

5/8" TYPE X GYPSUM WALL

BOARD

EXISTING METAL LINER PANEL

EXISTING STEEL CHANNEL,

SEE STRUCTURAL

EXISTING STEEL CHANNEL,

TYP., SEE STRUCTURAL

3 5/8" METAL STUD WALL

EXISTING CORRUGATED

METAL PANEL SIDING

EXISTING RIGID INSULATION

EXISTING CONCRETE

FOUNDATION, SEE STRUCTURAL

EXISTING GRADE

STANDING SEAM METAL ROOF

SYSTEM

3" RIGID INSULATION

EXISTING ROOF STRUCTURE,

SEE STRUCTURAL

METAL DECK, SEE STRUCTURAL

METAL JOIST, SEE STRUCTURAL

STEEL TUBE, SEE STRUCTURAL

ACOUSTICAL CEILING SYSTEM

3" BATT INSULATION

5/8" TYPE X GYPSUM WALL

BOARD

3" BATT INSULATION

10" METAL STUD WALL,

SEE STRUCTURAL

CORRUGATED METAL PANEL

SIDING TO MATCH EXISTING

RIGID INSULATION

EXISTING CONCRETE

FOUNDATION, SEE

STRUCTURAL

EXISTING GRADE

3" RIGID INSULATION

EXISTING ROOF STRUCTURE,

SEE STRUCTURAL

SUPPORT STRUCTURE, SEE

STRUCTURAL

EXISTING CORRUGATED

METAL WALL PANEL WITH

INSULATION AND METAL

CLOSURE DRIP EDGE

130' - 1" AFF

HIGH ROOF

100'-0" AFF

LEVEL 1

S O

L I C

I T

A T

I O

N

N

O

F I L E

N

A M

E

D W

N

B

Y

C K

D

B

Y

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F I

U M

B E

R

S I Z

E

S U

B M

I T

T E

D

B

Y

P L O

T

S

C A

L E

I S

S U

E

D

A T

E

D A

T E

M A

R K

D E

S C

R I P

T I O

N

C O

N T

R A

C T

O

SHEET

IDENTIFICATION

D A

T E

A P

P R

SHEET OF

US Army Corps of Engineers

U S

A

R M

Y

C

O R

P S

F

E

N G

I N

E E

R S

C O

N C

O R

D

M

A

N E

W

E

N G

L A

D

I S

T R

I C

T

A

Yo rk

Str ee t Po rtla nd

, M ai ne

7.5

.77 co lb yc oe ng ine er ing .c om

R E

N O

V A

T

B

U I L

D I N

G

F O

R

L

O G

I S

T I C

R

A

D I N

E S

S

S

Q U

A D

R O

N

P E

A S

E

A

I

T

I O

N A

L

G

U A

B

S

E

N

H

A N

S I

D

W

W J

B

I S

S U

F

C

N

S T

R U

C T

I O

N

B C

T

SCALE: 1/2" = 1'-0"

WALL SECTIONA1 REF. DWG.: A-301

C3 A-303

0 1' 2' 4'

Scale: 1/2" = 1'-0"

W A

L L

S

E C

T I O

N S

A-302

B L

B

C R

D

B C

T

A

D

W G

R T

M

SCALE: 1/2" = 1'-0"

WALL SECTIONA2 REF. DWG.: A-301

B3 A-303

COMMERCIAL SEMI-HEATED

MATERIAL R-VALUE PER INCH THICKNESS TOTAL R-VALUE

ROOF

POLYISO RIGID INSULATION 5 R 3 INCHES 15 R

FIBERGLASS BATT INSULATION 3.10 R 3 INCHES 9.30 R

TOTAL 24.30 R

WALLS

POLYISO RIGID INSULATION 5 R 2 INCHES 10 R

FIBERGLASS BATT INSULATION 3.10 R 3 INCHES 9.30 R

TOTAL 19.30 R

02/28/19