Amd_0008_RFI_7__Attachment_Drawings.pdf

PDF 958 KB Posted

Attached to
Burlington Air National Guard Base, South Burlington, VT
Solicitation number
W912WJ18B0010
Issued by

About this file

Drawing

View the file

Other files

Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

The Green

Mountain Boys

NOT FOR

CONSTRUCTION

92654

S c a l e

F o r

M i c r o f i l m i n g

I n c h e s

M i l l i m e t e r s date detailed checkeddesigned project contract rev.drawing file

C O

P Y

R I G

H T

B

U R

N S

A

D

M c D

O N

N E

L

E

G

I N

E E

R I N

G

C

O M

P A

N Y

I N

C

C

DATEREV.

REVISIONS

DESCRIPTION INIT

VERMONT AIR NATIONAL GUARD

BURLINGTON INTERNATIONAL AIRPORT

SO BURLINGTON, VERMONT

KANSAS CITY, MISSOURI

ENGINEERS ARCHITECTS & CONSULTANTS

Project No. - CURZ152804

F-35 LOW OBSERVABLE

COMPOSITE REPAIR FACILITY

BUILDING 132

D

C

A

B

E

D

C

A

B

E

5 61 2 3 4

5 61 2 3 4

92654B132-A201.DWG

D. SCOTTL. COLE

B. AMES

EA-201

EXTERIOR BUILDING ELEVATIONS

11/02/16

A B B A

1 2 3 4 512345

73'-8" 73'-8"

19'-0" 25'-0" 25'-0" 19'-0" 19'-0" 25'-0" 25'-0" 19'-0"

EXISTING UPWARD ACTING

VERTICAL LIFT HANGAR DOOR

TO REMAIN

D1

EXTERIOR ELEVATION

SCALE: 3/32" = 1'-0"

D3

EXTERIOR ELEVATION

SCALE: 3/32" = 1'-0"

A1

EXTERIOR ELEVATION

SCALE: 3/32" = 1'-0"

A3

EXTERIOR ELEVATION

SCALE: 3/32" = 1'-0"

NEW PRE-FINISHED INSULATED METAL

WALL PANELS (R-19), SEE

SPECIFICATIONS METAL PANEL TYPE

MP-1, INSTALLED OVER EXISTING

STRUCTURE

NEW EPDM ROOF MEMBRANE (BLACK)

OVER R-30 RIGID INSULATION OVER AIR

BARRIER OVER NEW STRUCTURAL

STEEL DECKING OVER EXISTING

STRUCTURE

NEW ROOF TOP PCA

(PRE-CONDITIONED AIR MOUNTED ON

NEW GALVANIZED STEEL SUPPORT

STRUCTURE, RE: ROOF PENETRATION

DETAIL E4/A-502 NEW ROOF TOP PCA

(PRE-CONDITIONED AIR MOUNTED ON

NEW GALVANIZED STEEL SUPPORT

STRUCTURE, RE: ROOF PENETRATION

DETAIL E4/A-502

NEW ROOF TOP PCA

(PRE-CONDITIONED AIR MOUNTED ON

NEW GALVANIZED STEEL SUPPORT

STRUCTURE, RE: ROOF PENETRATION

DETAIL E4/A-502

INSULATED DISCHARGE

DUCT AND ROOF CURB, RE: ROOF

PENETRATION DETAIL B1/A-502

INSULATED DISCHARGE

DUCT AND ROOF CURB, RE:

ROOF PENETRATION DETAIL

B1/A-502 NEW PRE-FINISHED INSULATED METAL

WALL PANELS (R-19), SEE

SPECIFICATIONS METAL PANEL TYPE

MP-1, INSTALLED OVER EXISTING

STRUCTURE

EXISTING DOOR, FRAME,

METAL RAILING TO BE

CLEANED AND REPAINTED

EXISTING DOOR, FRAME,

METAL RAILING TO BE

CLEANED AND REPAINTED

DS

EXTERIOR FINISH LEGEND

01 NOT USED

EXTERIOR WALL PANEL (FIELD), BASIS OF DESIGN: CENTRIA, COLOR: 992

LEE IVORY

03 EXTERIOR ROOF MEMBRANE, COLOR, BLACK

05 NOT USED

06 NOT USED

07 EXTERIOR EAVE TRIM, GUTTER, DOWNSPOUT AND FASCIA,

BASIS OF DESIGN: CENTRIA, COLOR: 992 LEE IVORY

NOT USED

08 NOT USED

DS

NEW PRE-FINISHED METAL

GUTTER AND

DOWNSPOUTS (DS)

8'-6"12'-6" 4'-0"

'-0

FR

OM

T

OP

O

F

CO

NC

. W

AL

L

NEW PRE-FINISHED

METAL LOUVER, SEE

A-601 FOR DETAILS

AND SPECIFICATIONS

A JLC10/20/17 B.2 SUBMITTAL

6" X 6" CAST IRON

DOWNSPOUT BOOT, RE:

DETAIL B3/A-501

NOTE: METAL WALL LOUVER, COLOR TO MATCH ADJACENT WALL PANEL COLOR

2'- 6"

NEW EPDM ROOF MEMBRANE

(BLACK) OVER R-30 RIGID

INSULATION OVER AIR BARRIER

OVER NEW STRUCTURAL STEEL

DECKING OVER EXISTING

STRUCTURE

UTILITY TRUSS TO REMAIN

BID OPTION 32 - PROVIDE NEW

CUSTOM FABRIC AWNING

STRUCTURE. SEE AWNING

ELEVATIONS

BASE BID - EXISTING AWNING TO

REMAIN AND SHALL BE BE

CLEANED.

C2

AWNING ELEVATIONS - BID OPTION 32

SCALE: 1/4" = 1'-0"

12FABRIC AWNING MATERIAL

CLEAR MATERIAL

FABRIC AWNING MATERIAL

METAL FLASHING AND

SEALANT. DETAIL BY

AWNING MANUF.

FASTEN CANOPY

STRUCTURE TO FACE OF

CONCRETE. DETAIL PER

AWNING MANUF.

8'- 0"

8" 10'-0" 4'-2"

V.I.F

4" YELLOW

PRINTED

LETTERS

2'- 6"

8"

8'-

8"

CLEAR MATERIAL

FASTEN CANOPY

STRUCTURE TO FACE OF

CONCRETE. DETAIL PER

AWNING MANUF.

FABRIC AWNING MATERIAL

FABRIC AWNING MATERIAL

FABRIC AWNING

MATERIAL

B JLC12/12/17 B.3 SUBMITTAL

SCALE IN FEET

0 2' 4' 8'

24'

SCALE IN FEET

0 8' 16' 24'

SCALE IN FEET

0 8' 16'

24'

SCALE IN FEET

0 8' 16' 24'

SCALE IN FEET

0 8' 16'

NEW CAGED ROOF ACCESS

LADDER, SEE SHEET A-502

FOR DETAILS. IF INTERIOR

ROOF ACCESS LADDER

OPTION SELECTED EXTERIOR

ROOF ACCESS LADDER NOT

REQUIRED.

NEW CAGED ROOF ACCESS

LADDER, SEE SHEET A-502

FOR DETAILS. IF INTERIOR

ROOF ACCESS LADDER

OPTION SELECTED EXTERIOR

ROOF ACCESS LADDER NOT

REQUIRED.

NEW CAGED ROOF ACCESS

LADDER, SEE SHEET A-502

FOR DETAILS. IF INTERIOR

ROOF ACCESS LADDER

OPTION SELECTED EXTERIOR

ROOF ACCESS LADDER NOT

REQUIRED.

C 3/2/18 B.3 FINAL SUBMITTAL

D JLC04/06/18 RTA

* EXACT LOCATION OF

LOUVER SHALL BE

COORDINATED IN FIELD

TO AVOID EXISTING

GIRTS

AMENDMENT 0008E 06/05/18 JLC

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

NON-METALLIC

SHIM

LO

UV

ER

H

EI

GH

T 2'

- 6

NEW STORM-RESISTANT

METAL LOUVER

CONTINUOUS

SEALANT

NEW PRE-FINISHED

VERTICAL 2" INSULATED

METAL PANEL ATTACHED

TO EXISTING STRUCTURE

CONTINUOUS SHEET

METAL FLASHING

NEW CONTINUOUS

GALVANIZED L3" x 3" x 1/4"

AT HEAD, SILL, AND EACH JAMB

CONTINUOUS

SEALANT

NEW STRUCTURAL

STEEL FRAMING

RE: STRUCTURAL

BIRD SCREEN

EXISTING LINER PANEL

NEW EDGE TRIM

LO

UV

ER

H

EI

GH

T 2'

- 6

NON-METALLIC SHIM

NEW STORM-RESISTANT

METAL LOUVER

CONTINUOUS SEALANT

CONTINUOUS SHEET

METAL FLASHING

NEW CONTINUOUS

GLAVANIZED L3" x 3" x 1/4" AT

HEAD, SILL, AND EACH JAMB

CONTINUOUS SEALANT

NEW VERTICAL 2"

CORRUGATED INSULATED

METAL PANEL SYSTEM

BIRD SCREEN

NEW STRUCTURAL STEEL

FRAMING, RE: STRUCTURAL

NEW EDGE TRIM

EXISTING LINER PANEL

LO

UV

ER

W

ID

TH

4'

- 0

NEW STORM-RESISTANT

METAL LOUVER

CONTINUOUS SEALANT

AND BACKER ROD

NON-METALLIC SHIM

NEW CONTINUOUS

GALVANIZED L3" x 3" x 1/4"

AT HEAD, SILL, AND EACH JAMB

NEW STRUCTURAL STEEL

FRAMING, RE: STRUCTURAL

BIRD SCREEN

NEW PRE-FINISHED

VERTICAL 2" INSULATED

METAL PANEL ATTACHED

TO EXISTING STRUCTURE

NEW EDGE TRIM

EXISTING LINER PANEL

NOT FOR

CONSTRUCTION

92654

S c a l e

F o r

M i c r o f i l m i n g

I n c h e s

M i l l i m e t e r s date detailed checkeddesigned project contract rev.drawing file

C O

P Y

R I G

B

U R

S

D

M c D

O N

N E

E

G

I N

E E

R I N

G

C

O M

P A

N Y

I N

C

C

DATEREV.

REVISIONS

DESCRIPTION INIT

VERMONT AIR NATIONAL GUARD

BURLINGTON INTERNATIONAL AIRPORT

SO BURLINGTON, VERMONT

KANSAS CITY, MISSOURI

ENGINEERS ARCHITECTS & CONSULTANTS

Project No. - CURZ152804

F-35 LOW OBSERVABLE

COMPOSITE REPAIR FACILITY

BUILDING 132

D

C

A

B

E

D

C

A

B

E

5 61 2 3 4

5 61 2 3 4

92654B132-AN601.DWG

D. SCOTTL. COLE

B. AMES

EA-601

LOUVER DETAILS

11/02/16

LOUVER SPECIFICATIONS:

C4

DETAIL (HEAD)

SCALE: 1 1/2" = 1'-0"

0 1/2' 1' 1 1/2'

0 1/2' 1' 1 1/2'

0 1/2' 1' 1 1/2'

B4

DETAIL (JAMB)

SCALE: 1 1/2" = 1'-0"

A4

DETAIL (SILL)

SCALE: 1 1/2" = 1'-0"

1. METAL WALL LOUVERS:

LOUVER BASIS OF DESIGN OR EQUAL: RUSKIN ELC6375DAX DRAINABLE CONBINATION LOUVER

WITH 24-VOLT DAMPER ACTUATOR (AS RECOMMENDED BY LOUVER MANUF.), WITH BIRD

SCREENS AND MADE TO WITHSTAND A WIND LOAD OF NOT LESS THAN 30 POUNDS PER SQUARE

FOOT. WALL LOUVERS SHALL BEAR THE AMCA CERTIFIED RATINGS PROGRAM SEAL FOR AIR

PERFORMANCE AND WATER PENETRATION IN ACCORDANCE WITH AMCA 500-D AND AMCA 511.

THE RATING SHALL SHOW A WATER PENETRATION OF 0.05 OR LESS OUNCE PER SQUARE FOOT

OF FREE AREA AT A FREE VELOCITY OF 800 FEET PER MINUTE. LOUVERS SHALL BE A MINIMUM

OF 6 INCHES DEEP. ALL LOUVERS USED TO INTAKE AIR SHALL BE DRAINABLE.

2. CLEAN AND PRIME EXPOSED SURFACES. PROVIDE A HIGH-PERFORMANCE FINISH IN

ACCORDANCE WITH AAMA 2605 WITH TOTAL DRY FILM THICKNESS OF NOT LESS THAN 1.2 MIL, COLOR TO MATCH ADJACENT WALL PANEL COLOR, SEE A-201 FOR EXTERIOR FINISH SCHEDULE

A JLC10/20/17 B.2 SUBMITTAL

B JLC12/12/17 B.3 SUBMITTAL

C 3/2/18 B.3 FINAL SUBMITTAL

D JLC04/06/18 RTA

AMENDMENT 0008E 06/05/18

JLC

JLC

TOC

100' - 0"

2 3

8' - 6" 4' - 0"

T/STL EL 126' - 6"

B/STL EL 124' - 0"

MC8X21.4

LOUVER

PER ARCH

C8x11.5

C3

S-302

C4

S-302

TYP 4

PLCS

TYP 2

PLCS

3/16 3

3/16 3

TYP

T/STL EL 126' - 6"

B/STL EL 124' - 0"

MC8

1/4" PL W/ (2) 3/4" DIA BOLTS3/16

3/16

MC8

C8

NOT FOR

CONSTRUCTION

92654

S c a le

F o r M ic ro fi lm in g

In c h e s

M il li m e te rs date detailed checkeddesigned project contract rev.drawing fileC O

P Y

R

IG

B

U R

N S

A N

D M c D

O N

N E

L L E

N G

IN

E

E R

IN

G

C O

M P

A N

Y

IN

C

C

DATEREV.

REVISIONS

DESCRIPTION INIT

VERMONT AIR NATIONAL GUARD

BURLINGTON INTERNATIONAL AIRPORT

SO BURLINGTON, VERMONT

KANSAS CITY, MISSOURI

ENGINEERS ARCHITECTS & CONSULTANTS

Project No. - CURZ152804

F-35 LOW OBSERVABLE

COMPOSITE REPAIR FACILITY

BUILDING 132

D

C

A

B

E

D

C

A

B

E

5 61 2 3 4

5 61 2 3 4

AS-302

LOUVER FRAMING

06/05/18

W. BAILEY P. MANIS

C. MCGEE

A 6/5/18 AMENDMENT 0008 WB

SCALE: 1/4" = 1'-0"C1

GIRT FRAMING AT LOUVER

SCALE: 1" = 1'-0"C3

SECTION

SCALE: 1 1/2" = 1'-0"C4

SECTION

0 2' 4' 8' 0 1/2' 1' 2' 0 1/2' 1' 1 1/2'

92654B132-A201-A-201
92654B132-AN601-A-601
S-302
Sheets
S-302 - LOUVER FRAMING

File details come from the government source that posted it.