Amd_0008_RFI_7__Attachment_Drawings.pdf
PDF 958 KB Posted
- Solicitation number
- W912WJ18B0010
About this file
Drawing
View the file
Other files
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
The Green
Mountain Boys
NOT FOR
CONSTRUCTION
92654
S c a l e
F o r
M i c r o f i l m i n g
I n c h e s
M i l l i m e t e r s date detailed checkeddesigned project contract rev.drawing file
C O
P Y
R I G
H T
B
U R
N S
A
D
M c D
O N
N E
L
E
G
I N
E E
R I N
G
C
O M
P A
N Y
I N
C
C
DATEREV.
REVISIONS
DESCRIPTION INIT
VERMONT AIR NATIONAL GUARD
BURLINGTON INTERNATIONAL AIRPORT
SO BURLINGTON, VERMONT
KANSAS CITY, MISSOURI
ENGINEERS ARCHITECTS & CONSULTANTS
Project No. - CURZ152804
F-35 LOW OBSERVABLE
COMPOSITE REPAIR FACILITY
BUILDING 132
D
C
A
B
E
D
C
A
B
E
5 61 2 3 4
5 61 2 3 4
92654B132-A201.DWG
D. SCOTTL. COLE
B. AMES
EA-201
EXTERIOR BUILDING ELEVATIONS
11/02/16
A B B A
1 2 3 4 512345
73'-8" 73'-8"
19'-0" 25'-0" 25'-0" 19'-0" 19'-0" 25'-0" 25'-0" 19'-0"
EXISTING UPWARD ACTING
VERTICAL LIFT HANGAR DOOR
TO REMAIN
D1
EXTERIOR ELEVATION
SCALE: 3/32" = 1'-0"
D3
EXTERIOR ELEVATION
SCALE: 3/32" = 1'-0"
A1
EXTERIOR ELEVATION
SCALE: 3/32" = 1'-0"
A3
EXTERIOR ELEVATION
SCALE: 3/32" = 1'-0"
NEW PRE-FINISHED INSULATED METAL
WALL PANELS (R-19), SEE
SPECIFICATIONS METAL PANEL TYPE
MP-1, INSTALLED OVER EXISTING
STRUCTURE
NEW EPDM ROOF MEMBRANE (BLACK)
OVER R-30 RIGID INSULATION OVER AIR
BARRIER OVER NEW STRUCTURAL
STEEL DECKING OVER EXISTING
STRUCTURE
NEW ROOF TOP PCA
(PRE-CONDITIONED AIR MOUNTED ON
NEW GALVANIZED STEEL SUPPORT
STRUCTURE, RE: ROOF PENETRATION
DETAIL E4/A-502 NEW ROOF TOP PCA
(PRE-CONDITIONED AIR MOUNTED ON
NEW GALVANIZED STEEL SUPPORT
STRUCTURE, RE: ROOF PENETRATION
DETAIL E4/A-502
NEW ROOF TOP PCA
(PRE-CONDITIONED AIR MOUNTED ON
NEW GALVANIZED STEEL SUPPORT
STRUCTURE, RE: ROOF PENETRATION
DETAIL E4/A-502
INSULATED DISCHARGE
DUCT AND ROOF CURB, RE: ROOF
PENETRATION DETAIL B1/A-502
INSULATED DISCHARGE
DUCT AND ROOF CURB, RE:
ROOF PENETRATION DETAIL
B1/A-502 NEW PRE-FINISHED INSULATED METAL
WALL PANELS (R-19), SEE
SPECIFICATIONS METAL PANEL TYPE
MP-1, INSTALLED OVER EXISTING
STRUCTURE
EXISTING DOOR, FRAME,
METAL RAILING TO BE
CLEANED AND REPAINTED
EXISTING DOOR, FRAME,
METAL RAILING TO BE
CLEANED AND REPAINTED
DS
EXTERIOR FINISH LEGEND
01 NOT USED
EXTERIOR WALL PANEL (FIELD), BASIS OF DESIGN: CENTRIA, COLOR: 992
LEE IVORY
03 EXTERIOR ROOF MEMBRANE, COLOR, BLACK
05 NOT USED
06 NOT USED
07 EXTERIOR EAVE TRIM, GUTTER, DOWNSPOUT AND FASCIA,
BASIS OF DESIGN: CENTRIA, COLOR: 992 LEE IVORY
NOT USED
08 NOT USED
DS
NEW PRE-FINISHED METAL
GUTTER AND
DOWNSPOUTS (DS)
8'-6"12'-6" 4'-0"
'-0
FR
OM
T
OP
O
F
CO
NC
. W
AL
L
NEW PRE-FINISHED
METAL LOUVER, SEE
A-601 FOR DETAILS
AND SPECIFICATIONS
A JLC10/20/17 B.2 SUBMITTAL
6" X 6" CAST IRON
DOWNSPOUT BOOT, RE:
DETAIL B3/A-501
NOTE: METAL WALL LOUVER, COLOR TO MATCH ADJACENT WALL PANEL COLOR
2'- 6"
NEW EPDM ROOF MEMBRANE
(BLACK) OVER R-30 RIGID
INSULATION OVER AIR BARRIER
OVER NEW STRUCTURAL STEEL
DECKING OVER EXISTING
STRUCTURE
UTILITY TRUSS TO REMAIN
BID OPTION 32 - PROVIDE NEW
CUSTOM FABRIC AWNING
STRUCTURE. SEE AWNING
ELEVATIONS
BASE BID - EXISTING AWNING TO
REMAIN AND SHALL BE BE
CLEANED.
C2
AWNING ELEVATIONS - BID OPTION 32
SCALE: 1/4" = 1'-0"
12FABRIC AWNING MATERIAL
CLEAR MATERIAL
FABRIC AWNING MATERIAL
METAL FLASHING AND
SEALANT. DETAIL BY
AWNING MANUF.
FASTEN CANOPY
STRUCTURE TO FACE OF
CONCRETE. DETAIL PER
AWNING MANUF.
8'- 0"
8" 10'-0" 4'-2"
V.I.F
4" YELLOW
PRINTED
LETTERS
2'- 6"
8"
8'-
8"
CLEAR MATERIAL
FASTEN CANOPY
STRUCTURE TO FACE OF
CONCRETE. DETAIL PER
AWNING MANUF.
FABRIC AWNING MATERIAL
FABRIC AWNING MATERIAL
FABRIC AWNING
MATERIAL
B JLC12/12/17 B.3 SUBMITTAL
SCALE IN FEET
0 2' 4' 8'
24'
SCALE IN FEET
0 8' 16' 24'
SCALE IN FEET
0 8' 16'
24'
SCALE IN FEET
0 8' 16' 24'
SCALE IN FEET
0 8' 16'
NEW CAGED ROOF ACCESS
LADDER, SEE SHEET A-502
FOR DETAILS. IF INTERIOR
ROOF ACCESS LADDER
OPTION SELECTED EXTERIOR
ROOF ACCESS LADDER NOT
REQUIRED.
NEW CAGED ROOF ACCESS
LADDER, SEE SHEET A-502
FOR DETAILS. IF INTERIOR
ROOF ACCESS LADDER
OPTION SELECTED EXTERIOR
ROOF ACCESS LADDER NOT
REQUIRED.
NEW CAGED ROOF ACCESS
LADDER, SEE SHEET A-502
FOR DETAILS. IF INTERIOR
ROOF ACCESS LADDER
OPTION SELECTED EXTERIOR
ROOF ACCESS LADDER NOT
REQUIRED.
C 3/2/18 B.3 FINAL SUBMITTAL
D JLC04/06/18 RTA
* EXACT LOCATION OF
LOUVER SHALL BE
COORDINATED IN FIELD
TO AVOID EXISTING
GIRTS
AMENDMENT 0008E 06/05/18 JLC
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
NON-METALLIC
SHIM
LO
UV
ER
H
EI
GH
T 2'
- 6
NEW STORM-RESISTANT
METAL LOUVER
CONTINUOUS
SEALANT
NEW PRE-FINISHED
VERTICAL 2" INSULATED
METAL PANEL ATTACHED
TO EXISTING STRUCTURE
CONTINUOUS SHEET
METAL FLASHING
NEW CONTINUOUS
GALVANIZED L3" x 3" x 1/4"
AT HEAD, SILL, AND EACH JAMB
CONTINUOUS
SEALANT
NEW STRUCTURAL
STEEL FRAMING
RE: STRUCTURAL
BIRD SCREEN
EXISTING LINER PANEL
NEW EDGE TRIM
LO
UV
ER
H
EI
GH
T 2'
- 6
NON-METALLIC SHIM
NEW STORM-RESISTANT
METAL LOUVER
CONTINUOUS SEALANT
CONTINUOUS SHEET
METAL FLASHING
NEW CONTINUOUS
GLAVANIZED L3" x 3" x 1/4" AT
HEAD, SILL, AND EACH JAMB
CONTINUOUS SEALANT
NEW VERTICAL 2"
CORRUGATED INSULATED
METAL PANEL SYSTEM
BIRD SCREEN
NEW STRUCTURAL STEEL
FRAMING, RE: STRUCTURAL
NEW EDGE TRIM
EXISTING LINER PANEL
LO
UV
ER
W
ID
TH
4'
- 0
NEW STORM-RESISTANT
METAL LOUVER
CONTINUOUS SEALANT
AND BACKER ROD
NON-METALLIC SHIM
NEW CONTINUOUS
GALVANIZED L3" x 3" x 1/4"
AT HEAD, SILL, AND EACH JAMB
NEW STRUCTURAL STEEL
FRAMING, RE: STRUCTURAL
BIRD SCREEN
NEW PRE-FINISHED
VERTICAL 2" INSULATED
METAL PANEL ATTACHED
TO EXISTING STRUCTURE
NEW EDGE TRIM
EXISTING LINER PANEL
NOT FOR
CONSTRUCTION
92654
S c a l e
F o r
M i c r o f i l m i n g
I n c h e s
M i l l i m e t e r s date detailed checkeddesigned project contract rev.drawing file
C O
P Y
R I G
B
U R
S
D
M c D
O N
N E
E
G
I N
E E
R I N
G
C
O M
P A
N Y
I N
C
C
DATEREV.
REVISIONS
DESCRIPTION INIT
VERMONT AIR NATIONAL GUARD
BURLINGTON INTERNATIONAL AIRPORT
SO BURLINGTON, VERMONT
KANSAS CITY, MISSOURI
ENGINEERS ARCHITECTS & CONSULTANTS
Project No. - CURZ152804
F-35 LOW OBSERVABLE
COMPOSITE REPAIR FACILITY
BUILDING 132
D
C
A
B
E
D
C
A
B
E
5 61 2 3 4
5 61 2 3 4
92654B132-AN601.DWG
D. SCOTTL. COLE
B. AMES
EA-601
LOUVER DETAILS
11/02/16
LOUVER SPECIFICATIONS:
C4
DETAIL (HEAD)
SCALE: 1 1/2" = 1'-0"
0 1/2' 1' 1 1/2'
0 1/2' 1' 1 1/2'
0 1/2' 1' 1 1/2'
B4
DETAIL (JAMB)
SCALE: 1 1/2" = 1'-0"
A4
DETAIL (SILL)
SCALE: 1 1/2" = 1'-0"
1. METAL WALL LOUVERS:
LOUVER BASIS OF DESIGN OR EQUAL: RUSKIN ELC6375DAX DRAINABLE CONBINATION LOUVER
WITH 24-VOLT DAMPER ACTUATOR (AS RECOMMENDED BY LOUVER MANUF.), WITH BIRD
SCREENS AND MADE TO WITHSTAND A WIND LOAD OF NOT LESS THAN 30 POUNDS PER SQUARE
FOOT. WALL LOUVERS SHALL BEAR THE AMCA CERTIFIED RATINGS PROGRAM SEAL FOR AIR
PERFORMANCE AND WATER PENETRATION IN ACCORDANCE WITH AMCA 500-D AND AMCA 511.
THE RATING SHALL SHOW A WATER PENETRATION OF 0.05 OR LESS OUNCE PER SQUARE FOOT
OF FREE AREA AT A FREE VELOCITY OF 800 FEET PER MINUTE. LOUVERS SHALL BE A MINIMUM
OF 6 INCHES DEEP. ALL LOUVERS USED TO INTAKE AIR SHALL BE DRAINABLE.
2. CLEAN AND PRIME EXPOSED SURFACES. PROVIDE A HIGH-PERFORMANCE FINISH IN
ACCORDANCE WITH AAMA 2605 WITH TOTAL DRY FILM THICKNESS OF NOT LESS THAN 1.2 MIL, COLOR TO MATCH ADJACENT WALL PANEL COLOR, SEE A-201 FOR EXTERIOR FINISH SCHEDULE
A JLC10/20/17 B.2 SUBMITTAL
B JLC12/12/17 B.3 SUBMITTAL
C 3/2/18 B.3 FINAL SUBMITTAL
D JLC04/06/18 RTA
AMENDMENT 0008E 06/05/18
JLC
JLC
TOC
100' - 0"
2 3
8' - 6" 4' - 0"
T/STL EL 126' - 6"
B/STL EL 124' - 0"
MC8X21.4
LOUVER
PER ARCH
C8x11.5
C3
S-302
C4
S-302
TYP 4
PLCS
TYP 2
PLCS
3/16 3
3/16 3
TYP
T/STL EL 126' - 6"
B/STL EL 124' - 0"
MC8
1/4" PL W/ (2) 3/4" DIA BOLTS3/16
3/16
MC8
C8
NOT FOR
CONSTRUCTION
92654
S c a le
F o r M ic ro fi lm in g
In c h e s
M il li m e te rs date detailed checkeddesigned project contract rev.drawing fileC O
P Y
R
IG
B
U R
N S
A N
D M c D
O N
N E
L L E
N G
IN
E
E R
IN
G
C O
M P
A N
Y
IN
C
C
DATEREV.
REVISIONS
DESCRIPTION INIT
VERMONT AIR NATIONAL GUARD
BURLINGTON INTERNATIONAL AIRPORT
SO BURLINGTON, VERMONT
KANSAS CITY, MISSOURI
ENGINEERS ARCHITECTS & CONSULTANTS
Project No. - CURZ152804
F-35 LOW OBSERVABLE
COMPOSITE REPAIR FACILITY
BUILDING 132
D
C
A
B
E
D
C
A
B
E
5 61 2 3 4
5 61 2 3 4
AS-302
LOUVER FRAMING
06/05/18
W. BAILEY P. MANIS
C. MCGEE
A 6/5/18 AMENDMENT 0008 WB
SCALE: 1/4" = 1'-0"C1
GIRT FRAMING AT LOUVER
SCALE: 1" = 1'-0"C3
SECTION
SCALE: 1 1/2" = 1'-0"C4
SECTION
0 2' 4' 8' 0 1/2' 1' 2' 0 1/2' 1' 1 1/2'
| 92654B132-A201-A-201 |
| 92654B132-AN601-A-601 |
| S-302 |
| Sheets |
| S-302 - LOUVER FRAMING |