This solicitation is for the design/bid/build construction of an Aerial Port Facility located at Minneapolis-St Paul Air Reserve Station, Minnesota. The estimated construction cost is between $10-25 million, with a NAICS code of 236220 and size determination of $39.5 million. This is a full and open procurement requiring a 10% HUBZone price evaluation in accordance with FAR 19.1307. Funds are not presently available and no contract award will be made until appropriated funds are available. Offerors must comply with CCR/ORCA requirements through SAM, which is free of charge. Technical inquiries should be submitted via Bidder Inquiry in ProjNet. A site visit is available in accordance with FAR 52.236-27 ALT 1. The term "bid" may be used interchangeably with "proposal" throughout the solicitation.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Solicitation For Aerial Port Facility Minneapolis St-Paul ARS, MN
P2: 331663
Design Bid Build
Structural Interior Design
(SID)
Certified Final Design Submittal
08 June 2021
W912QR21R0039
ARIMS: 200A
Disposition: Maintain for 15yrs after construction
W912QR21R0039-0000
AERIAL PORT FACILITY
MINNEAPOLIS ST-PAUL ARS
MINNESOTA
PROJECT #: QJKL100004
P2# 331663
FY 2021
DESIGN Consultant Team:
Structural Interior Design Certified Final Design Submittal
19 MARCH 2021
Aerial Port Facility Structural Interior Design Minneapolis – Saint Paul ARS, Minnesota March 19, 2021
Table of Contents
1. Narrative of Interior Design Objective ...................................................................................Tab 1
2. Floor Plan..............................................................................................................................Tab 2
3. Reflected Ceiling Plan........................................................................................................... Tab 3
4. Color Schedule ..................................................................................................................... Tab 4
5. Interior Color Boards .............................................................................................................Tab 5
6. Room Finish Schedule ...........................................................................................................Tab 6
7. Finish Plans ...........................................................................................................................Tab 7
8. Signage Plans and Details ......................................................................................................Tab 8
9. Interior Elevations .................................................................................................................Tab 9
10. Exterior Elevations .............................................................................................................. Tab 10
11. Exterior Color Boards .......................................................................................................... Tab 11
Aerial Port Facility Final Design Submittal Minneapolis – Saint Paul ARS, Minnesota
Statement of Interior Design Objective The design team’s focus for the interior design is to provide a comfortable environment for the new facility that will include the fleet services, load planning, operations, first sergeant office, managers office space, parachute packing and rigging, and aerial delivery.
The design shall deliver a professional environment that is aesthetically pleasing, sustainable, efficient, and can be easily maintained. Our objective is to instill pride in the facility and promote productivity and excellence within the user. A structural interior design (SID) package is provided which addresses floors, walls, ceilings, and miscellaneous interior finishes.
The overall color palette will increase the comfort and productivity of the users. All finish selections will be in accordance with all applicable codes and standards.
The majority of the interior spaces will be provided with painted gypsum wallboard.
Porcelain wall tile will be provided in restrooms for ease of maintenance. Wall protection such as corner guards will be provided where required.
The floor finishes throughout the facility are durable and enhance the design whenever possible. The main corridors and lobby shall receive concrete with a clear penetrating sealer. The office areas are carpeted in a medium toned carpet tile with a nondirectional pattern. Communication rooms will have a static dissipative tile.
The restrooms have 12” x 24” neutral colored porcelain floor tile as well as a 12” x 24” porcelain wall tile. Floor tile will have a dark grout color, selected for ease of maintenance. The countertops in the restrooms will be a solid surface material. Toilet partitions are to be stainless steel.
Interior doors are painted hollow metal with painted hollow metal frames to match. The hollow metal frame paint color is selected to coordinate with other finishes and furnishings in the building.
Signage will be designed in accordance with the AMC sign standards and UFC 3-120-
01. They will be professionally made and appropriately sized for viewing distance and provided with tactical lettering as required for ABA standards.
Ceilings will be primarily 2’ x 2’ lay-in acoustical ceiling tiles. Toilets and wet areas will be provided with a water-resistant paint finish on a suspended gypsum board ceiling.
1 2 3 4 5
A
B
D
SHEET ID
P ar kw ay
L an e, S ui te
Pe ac ht re e C or ne rs , G
A
Ph on e (6
) 3
-7
Fa x
(6
) 3
-7
SI
ZE
AN
SI
D
FI
LE
N
AM
E:
SU
BM
IT
TE
D B
Y:
C H
EC
K
ED
B
Y:
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
IS
SU
E D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
US Army Corps of Engineers ® Louisville District
W
2Q R
-1 9-
D -X
XX
X
W
2Q R
-1 8-
D -0
PR
O
JE
C
T N
O
Q
JK
L1
P2
: 3
M
SP
A
ER
IA
L
PO
R
T
FA
C
IL
IT
Y
M
IN
N
EA
PO
LI
S-
SA
IN
T
PA
U
L
IA
P
AR
S M
IN
N
ES
O
TA
XX
-X
-X
XX
X
M
A R
C H
FI
LE
N
AM
E:
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
CERTIFIED FINAL DESIGN SUBMITTAL
3/
/2
1:
:1
PM
C :\U se rs
\b kg
\D oc um en ts \M y R ev it\
0_ Ar ch _B
G al la gh er 5S
B2 3.
rv t
G-003
U S
AC
E
LI
FE
S
AF
ET
Y
AN
D
C O
D E
R
EV
IE
W
P.
L
IT
TL
E
B.
G
AL
LA
G H
ER
B.
G
AL
LA
G H
ER
J.
IS
C H
M
AR
K D
E
SC
R
IP
TI
O
N D
A
TE
Qualified Fire Protection Engineer (QFPE) of Record
Architect-Engineer Design Certification of Fire Protection / Life Safety / Accessibility Code Requirements
Preparers of this document certify the accuracy, completeness, and incorporation of the
Aerial Port Facility - Minneapolis St-Paul ARS, Minnesota
Certified Final Submittal
Preparers of this docuemtn certify the accuracy and completeness of the Fire Protection and Life Safety features for this project indicated with the attached, completed signature forms.
all required fire protection, life safety, and accessibility features in this project for the indicated milestone review.
Signature Date
CERTIFICATION OF FIRE PROTECTION & LIFE SAFETY CODE REQUIREMENTS
R
F LED
LOC
C1
AE201
C1
AE203
C1
AE204
123127
101' - 8"22' - 8"65' - 8"
FF=100'-0" FF=100'-0"
FF=100'-0"
9'
6"
0"
AE302
B1
AE302
B1
AE301
A1
AE301
A1
AE301
C1
AE301
C1
G
F F
E E
D D
C C
B B
A A
5.5
5.5
C.3
2'
8"
2'
8"
102' - 8"87' - 4"
AE303
B1
AE303
B1
190' - 0"
6"25' - 10"25' - 0"25' - 0"25' - 10"21' - 8"16' - 0"20' - 6"29' - 2"6"
6"
0"
0"
6"
6"
0"
0"
6"
6"25' - 10"25' - 0"25' - 0"25' - 10"21' - 8" 16' - 0"
20' - 6"29' - 2"6"
0"
C1
AE202
BID OPTION: PARACHUTE
DRYING TOWER ADDITION
BID OPTION: COVERED LOADING
AREA CANOPY ADDITION
1/4" / 1'-0" 1/4" / 1'-0"
1/ 4"
1'
-0
1/ 4"
1'
-0
/4
3/ 8"
11' - 10" 13' - 2 3/4" 11' - 3"
BID OPTION: PRE-
MANUFACTURED CANOPY
BID OPTION: PRE-
MANUFACTURED CANOPY
BID OPTION: PRE-
MANUFACTURED CANOPY
BASE BID: PREFINISHED
MANUFACTURED CANOPY
BASE BID:
PREFINISHED
MANUFACTURED
CANOPY
SECTOR PLAN
AB
D C
1 2 3 4 5
A
B
D
SHEET ID
P ar kw ay
L an e, S ui te
Pe ac ht re e C or ne rs , G
A
Ph on e (6
) 3
-7
Fa x
(6
) 3
-7
SI
ZE
AN
SI
D
FI
LE
N
AM
E:
SU
BM
IT
TE
D B
Y:
C H
EC
K
ED
B
Y:
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
IS
SU
E D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
NORTH
US Army Corps of Engineers ® Louisville District
W
2Q R
-1 9-
D -X
XX
X
W
2Q R
-1 8-
D -0
PR
O
JE
C
T N
O
Q
JK
L1
P2
: 3
M
SP
A
ER
IA
L
PO
R
T
FA
C
IL
IT
Y
M
IN
N
EA
PO
LI
S-
SA
IN
T
PA
U
L
IA
P
AR
S M
IN
N
ES
O
TA
XX
-X
-X
XX
X
M
A R
C H
FI
LE
N
AM
E:
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
CERTIFIED FINAL DESIGN SUBMITTAL
3/
/2
4:
:1
PM
C :\U se rs
\b kg
\D oc um en ts \M y R ev it\
0_ Ar ch _B
G al la gh er 5S
B2 3.
rv t
AE101
C O
M
PO
SI
TE
F
LO
O R
P
LA
N P.
L
IT
TL
E
B.
G
AL
LA
G H
ER
B.
G
AL
LA
G H
ER
J.
IS
C H
SCALE: 3/32" = 1'-0"
COMPOSITE GROUND FLOOR PLANA1
ROOM NAME SCHED.
ROOM # ROOM NAME
DESIGN
AREA
101 VEST 59 SF
102 AR TECHS(2) 205 SF
103 1ST SGT 119 SF
104 CMDR 146 SF
105 CORR 609 SF
106 OPS ASST 96 SF
107 OPS 138 SF
108 BREAK ROOM 188 SF
109 VEST 60 SF
110 PROG/UDT/ UTM/SEC 451 SF
111 LOAD PLNG/ATOC 613 SF
112 CORRIDOR 117 SF
113 TRAINING A 804 SF
114 TRAINING B 729 SF
115 TRAINING C 748 SF
116 VEST 56 SF
117 CORR 373 SF
118 SPEC/HANDLING 537 SF
119 CARGO 633 SF
120 PAX 653 SF
121 RAMP 429 SF
122 CORRIDOR 527 SF
123 CONF 458 SF
124 JAN. 38 SF
125 WOMEN 236 SF
126 MEN 246 SF
127 EAGLE CR 1 324 SF
128 RIGGER OFFICE 220 SF
129 PACKING/RIGGING 1962 SF
130 CORRIDOR 674 SF
131 COPY 68 SF
132 CSS 331 SF
133 STO 31 SF
134 MGR'S 478 SF
135 FIRE PUMP 150 SF
136 ELEC. 159 SF
137 COMM. 146 SF
138 RIGGING STORAGE 335 SF
139 MOBILITY STORAGE 615 SF
140 AERIAL DELIVERY 5902 SF
141 VEHICLE STO HIGH BAY 3810 SF
142 COVERED LOADING
143 DRYING TOWER 388 SF
144 MECH PLATFORM 1952 SF
145 MECH 227 SF
SCALE: = 1'-0"3/32"
0 8 16 248
M
AR
K D
E
SC
R
IP
TI
O
N D
A
TE
RICHARD S.
JOHNSON
B
D
SHEET ID
P ar kw ay
L an e, S ui te
Pe ac ht re e C or ne rs , G
A
Ph on e (6
) 3
-7
Fa x
(6
) 3
-7
SI
ZE
AN
SI
D
FI
LE
N
AM
E:
SU
BM
IT
TE
D B
Y:
C H
EC
K
ED
B
Y:
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
IS
SU
E D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
US Army Corps of Engineers ® Louisville District
W
2Q R
-1 9-
D -X
XX
X
W
2Q R
-1 8-
D -0
PR
O
JE
C
T N
O
Q
JK
L1
P2
: 3
M
SP
A
ER
IA
L
PO
R
T
FA
C
IL
IT
Y
M
IN
N
EA
PO
LI
S-
SA
IN
T
PA
U
L
IA
P
AR
S M
IN
N
ES
O
TA
XX
-X
-X
XX
X
M
A R
C H
FI
LE
N
AM
E:
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
CERTIFIED FINAL DESIGN SUBMITTAL
3/
/2
1:
:1
PM
C :\U se rs
\b kg
\D oc um en ts \M y R ev it\
0_ Ar ch _B
G al la gh er 5S
B2 3.
rv t
G-003
U S
AC
E
LI
FE
S
AF
ET
Y
AN
D
C O
D E
R
EV
IE
W
P.
L
IT
TL
E
B.
G
AL
LA
G H
ER
B.
G
AL
LA
G H
ER
J.
IS
C H
M
AR
K D
E
SC
R
IP
TI
O
N D
A
TE
Qualified Fire Protection Engineer (QFPE) of Record
Architect-Engineer Design Certification of Fire Protection / Life Safety / Accessibility Code Requirements
Preparers of this document certify the accuracy, completeness, and incorporation of the
Aerial Port Facility - Minneapolis St-Paul ARS, Minnesota
Certified Final Submittal
Preparers of this docuemtn certify the accuracy and completeness of the Fire Protection and Life Safety features for this project indicated with the attached, completed signature forms.
all required fire protection, life safety, and accessibility features in this project for the indicated milestone review.
Signature Date
CERTIFICATION OF FIRE PROTECTION & LIFE SAFETY CODE REQUIREMENTS
OCO
C1
AE204
LOAD
PLNG/ATOC
TRAINING A
PROG/UDT/
UTM/SEC
SPEC/HANDLING
3'
4" 6'
4"
8'
0" 8'
0"
8'
0" 8'
0"
8'
0" 8'
0"
8'
0" 4'
2"
10' - 0"
1' - 11"
7' - 6"25' - 4"33' - 1"18' - 0"5' - 0"
EX1
EX2
EX2
EX2
EX2
EX2EX2EX2
BREAK
ROOM
VEST
TRAINING B
TRAINING C
CORR
VEST
CARGO
PAX
RAMP
CORRIDOR
CONF
MEN
WOMEN
RIGGER
OFFICE
2' - 4"
8' - 0"11' - 0"
3' - 4"
36' - 0"3' - 4"14' - 8"8' - 0"4' - 0"8' - 0"4' - 0"
AE302
B1
AE301
C1
123A
110A
116B
113B
120A
121A
119A
114A
118A
109B
124A 126A 125A128A
122A 109A
116A 113A
140A
18' - 8 1/2"38' - 3 1/2"6' - 5"36' - 7"
0"
/8
6'
7/
8"
/8
6'
7/
8"
/2
/2
6'
6"
A2
A2
A2
A2A2
A2
A2
A2
E1
E1
A4
A4
A4
A2
A2 A2
A2
A2
A2
C
B
A
12345
A2
C.3
6" 25' - 10"25' - 0"25' - 0"25' - 10"
190'-0"
M
AT
C H
LI
N
E
SE
E A
AE
MATCHLINE
SEE A1 /
AE104
6"
0"
2'
8"
C1
AE504
C2
AE504
AE304
A4
115B
A2
A2
A2
5 5 5
B4
AE504
D4
A4
AE505
C1
AE505
A2
AE505
E1
A2
A2
A2
9'
6" 3'
4"
6'
4" 5'
4"
6'
0" 8'
9"
5'
4"
/4
3' - 10 9/16"
3' - 4" 10"13' - 3 1/2"5' - 5"
18' - 0"12' - 2"
B3
AE403
DM
DM
DM
DM
4' - 2 3/4"
108A
A2
A2A2
A2
A2
A2
A2
A2 115A
EX2
2'-5 1/4"
3'-4"2'-0"
3' - 4"
A2
AE304
A1
E1
127A 5 1/
4"
CORRIDOR
3'
7/
8"
2'
3"
A3
AE501
111A
JAN.
EAGLE CR 1
A2
B2
AE504
C3
AE504
C3
AE504 SIMSIM
A4
AE506
SECTOR PLAN
AB
D C
1 2 3 4 5
A
B
D
SHEET ID
P ar kw ay
L an e, S ui te
Pe ac ht re e C or ne rs , G
A
Ph on e (6
) 3
-7
Fa x
(6
) 3
-7
SI
ZE
AN
SI
D
FI
LE
N
AM
E:
SU
BM
IT
TE
D B
Y:
C H
EC
K
ED
B
Y:
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
IS
SU
E D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
NORTH
US Army Corps of Engineers ® Louisville District
W
2Q R
-1 9-
D -X
XX
X
W
2Q R
-1 8-
D -0
PR
O
JE
C
T N
O
Q
JK
L1
P2
: 3
M
SP
A
ER
IA
L
PO
R
T
FA
C
IL
IT
Y
M
IN
N
EA
PO
LI
S-
SA
IN
T
PA
U
L
IA
P
AR
S M
IN
N
ES
O
TA
XX
-X
-X
XX
X
M
A R
C H
FI
LE
N
AM
E:
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
CERTIFIED FINAL DESIGN SUBMITTAL
3/
/2
4:
:2
PM
C :\U se rs
\b kg
\D oc um en ts \M y R ev it\
0_ Ar ch _B
G al la gh er 5S
B2 3.
rv t
AE102
FL
O
O R
P
LA
N -S
EC
TO
R A
P.
L
IT
TL
E
B.
G
AL
LA
G H
ER
B.
G
AL
LA
G H
ER
J.
IS
C H
SCALE: = 1'-0"
0 8 168
1/8"
GENERAL NOTES
A. ALL INTERIOR PARTITIONS SHALL BE TYPE "A2" -
UNLESS NOTED OTHERWISE
B. ALL INTERIOR DIMENSIONS ARE FROM FACE OF
STUD TO FACE OF STUD OR FACE OF CMU OR
CONCRETE AS INDICATED - UNLESS NOTED
OTHERWISE.
C. CONTRACTORS ARE FREE TO USE ANY PRODUCT
WHICH MEETS THE GOVERNMENT'S MINIMUM
REQUIREMENTS AND NOT IN CONFLICT WITH OTHER
CONTRACT PROVISIONS. UNLESS INDICATED
OTHERWISE ON THE PLANS OR SPECIFICATIONS (E.G.
SOLE-SOURCE), ALL LISTED MANUFACTURERS ARE THE
BASIS OF DESIGN. FOR THESE BASIS OF DESIGN
PRODUCTS, OTHER MANUFACTURERS MAY BE
SUBSTITUTED AS LONG AS THE STANDARD OF QUALITY
AND CHARACTERISTICS OF THE SUBSITUTED
MANUFACTURER MEET OR EXCEED THE STANDARD OF
QUALITY AND CHARACTERISTICS OF THE BASIS OF
DESIGN.
SCALE: 1/8" = 1'-0"
FLOOR PLAN - SECTOR AB2
SHEET KEYNOTES
LEGEND
1. 4" DIA CONCRETE FILLED STEEL PIPE BOLLARDS.
2. FIXED METAL SHIP LADDER.
3. UTILITY SINK.
4. MECHANICAL EQUIPMENT.
5. 6X6 PREFINISHED DOWNSPOUT & SPLASH BLOCK -
GUTTER AND DOWNSPOUT COLOR TO MATCH
INSULATED METAL PANELS (IMWP1)
6. NOT USED
7. GRAVITY ROLLER SYSTEM - GFGI
8. PAINTED 1 1/2" OUTSIDE DIAMETER STEEL
GUARDRAIL.
9. 4'-0" REMOVABLE GUARDRAIL SECTIONS.
10. FIXED ALUMINUM MECHANICAL PLATFORM LADDER
11. 2-1/4" CLR INSIDE DIAMETER PIPE SLEEVES
EMBEDDED INTO CONCRETE SLAB - FINISH FLUSH
TO FLOOR - COORDINATE LOCATION WITH OWNER
12. PREFINISHED MANUFACTURED CANOPY
13. BID OPTION: UNIT ASSEMBLY PARTITIONS
VISUAL LINE OF
AIR BARRIER
BASE BID
NOTE: NOT
ALL USED
M
AR
K D
E
SC
R
IP
TI
O
N D
A
TE
RICHARD S.
JOHNSON
B
D
SHEET ID
P ar kw ay
L an e, S ui te
Pe ac ht re e C or ne rs , G
A
Ph on e (6
) 3
-7
Fa x
(6
) 3
-7
SI
ZE
AN
SI
D
FI
LE
N
AM
E:
SU
BM
IT
TE
D B
Y:
C H
EC
K
ED
B
Y:
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
IS
SU
E D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
US Army Corps of Engineers ® Louisville District
W
2Q R
-1 9-
D -X
XX
X
W
2Q R
-1 8-
D -0
PR
O
JE
C
T N
O
Q
JK
L1
P2
: 3
M
SP
A
ER
IA
L
PO
R
T
FA
C
IL
IT
Y
M
IN
N
EA
PO
LI
S-
SA
IN
T
PA
U
L
IA
P
AR
S M
IN
N
ES
O
TA
XX
-X
-X
XX
X
M
A R
C H
FI
LE
N
AM
E:
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
CERTIFIED FINAL DESIGN SUBMITTAL
3/
/2
1:
:1
PM
C :\U se rs
\b kg
\D oc um en ts \M y R ev it\
0_ Ar ch _B
G al la gh er 5S
B2 3.
rv t
G-003
U S
AC
E
LI
FE
S
AF
ET
Y
AN
D
C O
D E
R
EV
IE
W
P.
L
IT
TL
E
B.
G
AL
LA
G H
ER
B.
G
AL
LA
G H
ER
J.
IS
C H
M
AR
K D
E
SC
R
IP
TI
O
N D
A
TE
Qualified Fire Protection Engineer (QFPE) of Record
Architect-Engineer Design Certification of Fire Protection / Life Safety / Accessibility Code Requirements
Preparers of this document certify the accuracy, completeness, and incorporation of the
Aerial Port Facility - Minneapolis St-Paul ARS, Minnesota
Certified Final Submittal
Preparers of this docuemtn certify the accuracy and completeness of the Fire Protection and Life Safety features for this project indicated with the attached, completed signature forms.
all required fire protection, life safety, and accessibility features in this project for the indicated milestone review.
Signature Date
CERTIFICATION OF FIRE PROTECTION & LIFE SAFETY CODE REQUIREMENTS
OCO
5' - 0"
EX2
RIGGER
OFFICE
AE302
B1
AE301
A1
141F
128A
122A
140A
0"
/8
E1
A4
A4
A4
C
B
A
55.5678
C.3
AE405 C1
AE405B1
AE303
B1
21' - 8"16' - 0"20' - 6"29' - 2"
190'-0"
M
AT
C H
LI
N
E
SE
E B
AE
6"
0"
C2
AE504
AE304
A4
1 1
2'
-8 " D4
A2
12' - 2"
B3
AE403
2'-5 1/4"
3'-4"2'-0"12'-0"4'-0"12'-0"4'-0"12'-0"7'-0"4'-2"18'-0"6'-4 3/4"
141E 140B140C140D
B2
AE604
127A 5 1/
4"
EAGLE CR 1
AERIAL
DELIVERY
VEHICLE STO
HIGH BAY
MATCHLINE
SEE A1 /
AE105
1/4" / 1'-0" 1/4" / 1'-0"
1/ 4"
1'
-0
AE301
A1
B
A
55.5678
B2
AE604
COVERED
LOADING
141F 140A
21' - 8"16' - 0"20' - 6"29' - 2"
190'-0"
1 1
5 5 5
2' - 5 81/256"
3' - 4" 2' - 0"
12' - 0"4' - 0"12' - 0"
4' - 0"
12' - 0"7' - 0"4' - 2"18' - 0"6' - 4 175/256"
141E 140B140C140D
(4)(4)(4)
MATCHLINE
SEE B2 /
AE102
AE308
A4
SECTOR PLAN
AB
D C
1 2 3 4 5
A
B
D
SHEET ID
P ar kw ay
L an e, S ui te
Pe ac ht re e C or ne rs , G
A
Ph on e (6
) 3
-7
Fa x
(6
) 3
-7
SI
ZE
AN
SI
D
FI
LE
N
AM
E:
SU
BM
IT
TE
D B
Y:
C H
EC
K
ED
B
Y:
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
IS
SU
E D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
NORTH
US Army Corps of Engineers ® Louisville District
W
2Q R
-1 9-
D -X
XX
X
W
2Q R
-1 8-
D -0
PR
O
JE
C
T N
O
Q
JK
L1
P2
: 3
M
SP
A
ER
IA
L
PO
R
T
FA
C
IL
IT
Y
M
IN
N
EA
PO
LI
S-
SA
IN
T
PA
U
L
IA
P
AR
S M
IN
N
ES
O
TA
XX
-X
-X
XX
X
M
A R
C H
FI
LE
N
AM
E:
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
CERTIFIED FINAL DESIGN SUBMITTAL
3/
/2
4:
:2
PM
C :\U se rs
\b kg
\D oc um en ts \M y R ev it\
0_ Ar ch _B
G al la gh er 5S
B2 3.
rv t
AE103
FL
O
O R
P
LA
N -S
EC
TO
R B
P.
L
IT
TL
E
B.
G
AL
LA
G H
ER
B.
G
AL
LA
G H
ER
J.
IS
C H
SCALE: 1/8" = 1'-0"
FLOOR PLAN - SECTOR BA1
SCALE: = 1'-0"
0 8 168
1/8"
LEGEND VISUAL LINE OF
AIR BARRIER
SCALE: 1/8" = 1'-0"
FLOOR PLAN - SECTOR BA3
BASE BID BID OPTION: COVERED LOADING AREA
CANOPY ADDITION
GENERAL NOTES
SHEET KEYNOTES
1. 4" DIA CONCRETE FILLED STEEL PIPE BOLLARDS.
2. FIXED METAL SHIP LADDER.
3. UTILITY SINK.
4. MECHANICAL EQUIPMENT.
5. 6X6 PREFINISHED DOWNSPOUT & SPLASH BLOCK -
GUTTER AND DOWNSPOUT COLOR TO MATCH
INSULATED METAL PANELS (IMWP1)
6. NOT USED
7. GRAVITY ROLLER SYSTEM - GFGI
8. PAINTED 1 1/2" OUTSIDE DIAMETER STEEL
GUARDRAIL.
9. 4'-0" REMOVABLE GUARDRAIL SECTIONS.
10. FIXED ALUMINUM MECHANICAL PLATFORM LADDER
11. 2-1/4" CLR INSIDE DIAMETER PIPE SLEEVES
EMBEDDED INTO CONCRETE SLAB - FINISH FLUSH
TO FLOOR - COORDINATE LOCATION WITH OWNER
12. BID OPTION: PREFINISHED MANUFACTURED
CANOPY
NOTE: NOT
ALL USED
A. ALL INTERIOR PARTITIONS SHALL BE TYPE "A2" -
UNLESS NOTED OTHERWISE
B. ALL INTERIOR DIMENSIONS ARE FROM FACE OF
STUD TO FACE OF STUD OR FACE OF CMU OR
CONCRETE AS INDICATED - UNLESS NOTED
OTHERWISE.
C. CONTRACTORS ARE FREE TO USE ANY PRODUCT
WHICH MEETS THE GOVERNMENT'S MINIMUM
REQUIREMENTS AND NOT IN CONFLICT WITH OTHER
CONTRACT PROVISIONS. UNLESS INDICATED
OTHERWISE ON THE PLANS OR SPECIFICATIONS (E.G.
SOLE-SOURCE), ALL LISTED MANUFACTURERS ARE THE
BASIS OF DESIGN. FOR THESE BASIS OF DESIGN
PRODUCTS, OTHER MANUFACTURERS MAY BE
SUBSTITUTED AS LONG AS THE STANDARD OF QUALITY
AND CHARACTERISTICS OF THE SUBSITUTED
MANUFACTURER MEET OR EXCEED THE STANDARD OF
QUALITY AND CHARACTERISTICS OF THE BASIS OF
DESIGN.
M
AR
K D
E
SC
R
IP
TI
O
N D
A
TE
RICHARD S.
JOHNSON
B
D
SHEET ID
P ar kw ay
L an e, S ui te
Pe ac ht re e C or ne rs , G
A
Ph on e (6
) 3
-7
Fa x
(6
) 3
-7
SI
ZE
AN
SI
D
FI
LE
N
AM
E:
SU
BM
IT
TE
D B
Y:
C H
EC
K
ED
B
Y:
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
IS
SU
E D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
US Army Corps of Engineers ® Louisville District
W
2Q R
-1 9-
D -X
XX
X
W
2Q R
-1 8-
D -0
PR
O
JE
C
T N
O
Q
JK
L1
P2
: 3
M
SP
A
ER
IA
L
PO
R
T
FA
C
IL
IT
Y
M
IN
N
EA
PO
LI
S-
SA
IN
T
PA
U
L
IA
P
AR
S M
IN
N
ES
O
TA
XX
-X
-X
XX
X
M
A R
C H
FI
LE
N
AM
E:
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
CERTIFIED FINAL DESIGN SUBMITTAL
3/
/2
1:
:1
PM
C :\U se rs
\b kg
\D oc um en ts \M y R ev it\
0_ Ar ch _B
G al la gh er 5S
B2 3.
rv t
G-003
U S
AC
E
LI
FE
S
AF
ET
Y
AN
D
C O
D E
R
EV
IE
W
P.
L
IT
TL
E
B.
G
AL
LA
G H
ER
B.
G
AL
LA
G H
ER
J.
IS
C H
M
AR
K D
E
SC
R
IP
TI
O
N D
A
TE
Qualified Fire Protection Engineer (QFPE) of Record
Architect-Engineer Design Certification of Fire Protection / Life Safety / Accessibility Code Requirements
Preparers of this document certify the accuracy, completeness, and incorporation of the
Aerial Port Facility - Minneapolis St-Paul ARS, Minnesota
Certified Final Submittal
Preparers of this docuemtn certify the accuracy and completeness of the Fire Protection and Life Safety features for this project indicated with the attached, completed signature forms.
all required fire protection, life safety, and accessibility features in this project for the indicated milestone review.
Signature Date
CERTIFICATION OF FIRE PROTECTION & LIFE SAFETY CODE REQUIREMENTS
R
T
T H
AR TECHS(2)
VEST
1ST SGT
CMDR
OPS ASST
4' - 0"4' - 0"6' - 0"6' - 4"9' - 4"4' - 0"
2' - 8"
4' - 0"4' - 0"4' - 0"4' - 9"6' - 4"18' - 4"6' - 4"
3'
4'
0"
4'
0"
4'
0"
4'
0"
4'
0"
10' - 0"
1' - 11"
7' - 6"25' - 4"33' - 1"18' - 0"5' - 0"
EX1EX1EX1EX1
EX1
EX1
EX1
EX1BREAK
ROOM
CORR
VEST
CORRIDOR
CONF
MEN
WOMEN
EAGLE CR 1
127RIGGER
OFFICE
PACKING/RIGGING
86' - 5 3/4"
CORRIDOR
STO
COPY
CSS
MGR'S
COMM.
MECH
FIRE PUMP
AE301
C1
AE301
C1
B1
AE402
123A
109B
124A
102A
103A
104A
130A
101B
129B
129C
143B
128B
133A
101A
129A
126A 125A128A
122A 109A
11' - 11"7' - 6"5' - 7"9' - 5"15' - 7" 1' - 1 5/8"
11' - 3"13' - 2 3/4"11' - 10"21' - 0 5/8"
1' - 4"
6' - 4"
8'
5/
8"
/4
E1
E1
A4
A4
A2
A2
A2 B3
A2
A4
A1A1 A2
A2
A2
E1
A2
A1
A2
A2
A2
A2
C1
AE403
B1
AE403
/8
1'
0" 3'
4"
2'
0"
2'
1/
4"
F
E
D
12345
A2
C.3
2'
-8
0"
0"
MATCHLINE
SEE B2 /
AE102
6"25' - 10"25' - 0"25' - 0"25' - 10"
5 5
B4
AE504
A2
AE504
A4
AE504
C3
AE504
C4
AE504
OPS
A1
AE505
C2
AE505
E1
A4
DM
A2
AE404C1
A2
A2
EX1
18' - 0"12' - 2" 18
0"
1'
1/
4" 4'
0"
135A
123B
132A
DM
DM
DM
DM
B3
B3
M2M2
ELEC.
MOBILITY
STORAGE
1' - 1 5/8"11' - 3"12' - 7 3/8" 7 3/8"
11' - 10"
B3
138A
136A137A138B
139A
107A
108A
M2
C1
AE202
A2
A2
(3) A2
E1
E1A2
127A
B1
AE404
B1
AE604
1/
4"
/4
/4
8'
3/ 8"
/8
11' - 8 3/8"1' - 4 5/8"
A5
AE504
5'
0" 7'
8"
134A
JAN.
AERIAL
DELIVERY
M
AT
C H
LI
N
E
SE
E A
AE
106A
A1
AE504
A2
RIGGING
STORAGE
B3
B3
B3
B3
145A
M2
B3
SECTOR PLAN
AB
D C
1 2 3 4 5
A
B
D
SHEET ID
P ar kw ay
L an e, S ui te
Pe ac ht re e C or ne rs , G
A
Ph on e (6
) 3
-7
Fa x
(6
) 3
-7
SI
ZE
AN
SI
D
FI
LE
N
AM
E:
SU
BM
IT
TE
D B
Y:
C H
EC
K
ED
B
Y:
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
IS
SU
E D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
NORTH
US Army Corps of Engineers ® Louisville District
W
2Q R
-1 9-
D -X
XX
X
W
2Q R
-1 8-
D -0
PR
O
JE
C
T N
O
Q
JK
L1
P2
: 3
M
SP
A
ER
IA
L
PO
R
T
FA
C
IL
IT
Y
M
IN
N
EA
PO
LI
S-
SA
IN
T
PA
U
L
IA
P
AR
S M
IN
N
ES
O
TA
XX
-X
-X
XX
X
M
A R
C H
FI
LE
N
AM
E:
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
CERTIFIED FINAL DESIGN SUBMITTAL
3/
/2
4:
:3
PM
C :\U se rs
\b kg
\D oc um en ts \M y R ev it\
0_ Ar ch _B
G al la gh er 5S
B2 3.
rv t
AE104
FL
O
O R
P
LA
N -S
EC
TO
R C
P.
L
IT
TL
E
B.
G
AL
LA
G H
ER
B.
G
AL
LA
G H
ER
J.
IS
C H
SCALE: 1/8" = 1'-0"
FLOOR PLAN - SECTOR CA1
SCALE: = 1'-0"
0 8 168
1/8"
BASE BID
GENERAL NOTES
SHEET KEYNOTES
LEGEND
1. 4" DIA CONCRETE FILLED STEEL PIPE BOLLARDS.
2. FIXED METAL SHIP LADDER.
3. UTILITY SINK.
4. MECHANICAL EQUIPMENT.
5. 6X6 PREFINISHED DOWNSPOUT & SPLASH BLOCK -
GUTTER AND DOWNSPOUT COLOR TO MATCH
INSULATED METAL PANELS (IMWP1)
6. NOT USED
7. GRAVITY ROLLER SYSTEM - GFGI
8. PAINTED 1 1/2" OUTSIDE DIAMETER STEEL
GUARDRAIL.
9. 4'-0" REMOVABLE GUARDRAIL SECTIONS.
10. FIXED ALUMINUM MECHANICAL PLATFORM LADDER
11. 2-1/4" CLR INSIDE DIAMETER PIPE SLEEVES
EMBEDDED INTO CONCRETE SLAB - FINISH FLUSH
TO FLOOR - COORDINATE LOCATION WITH OWNER
12. PREFINISHED MANUFACTURED CANOPY
13. GAS METER
14. METAL LOCKERS
15. FIRE RISER
VISUAL LINE OF
AIR BARRIER
A. ALL INTERIOR PARTITIONS SHALL BE TYPE "A2" -
UNLESS NOTED OTHERWISE
B. ALL INTERIOR DIMENSIONS ARE FROM FACE OF
STUD TO FACE OF STUD OR FACE OF CMU OR
CONCRETE AS INDICATED - UNLESS NOTED
OTHERWISE.
C. CONTRACTORS ARE FREE TO USE ANY PRODUCT
WHICH MEETS THE GOVERNMENT'S MINIMUM
REQUIREMENTS AND NOT IN CONFLICT WITH OTHER
CONTRACT PROVISIONS. UNLESS INDICATED
OTHERWISE ON THE PLANS OR SPECIFICATIONS (E.G.
SOLE-SOURCE), ALL LISTED MANUFACTURERS ARE THE
BASIS OF DESIGN. FOR THESE BASIS OF DESIGN
PRODUCTS, OTHER MANUFACTURERS MAY BE
SUBSTITUTED AS LONG AS THE STANDARD OF QUALITY
AND CHARACTERISTICS OF THE SUBSITUTED
MANUFACTURER MEET OR EXCEED THE STANDARD OF
QUALITY AND CHARACTERISTICS OF THE BASIS OF
DESIGN.
NOTE: NOT
ALL USED
M
AR
K D
E
SC
R
IP
TI
O
N D
A
TE
RICHARD S.
JOHNSON
B
D
SHEET ID
P ar kw ay
L an e, S ui te
Pe ac ht re e C or ne rs , G
A
Ph on e (6
) 3
-7
Fa x
(6
) 3
-7
SI
ZE
AN
SI
D
FI
LE
N
AM
E:
SU
BM
IT
TE
D B
Y:
C H
EC
K
ED
B
Y:
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
IS
SU
E D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
US Army Corps of Engineers ® Louisville District
W
2Q R
-1 9-
D -X
XX
X
W
2Q R
-1 8-
D -0
PR
O
JE
C
T N
O
Q
JK
L1
P2
: 3
M
SP
A
ER
IA
L
PO
R
T
FA
C
IL
IT
Y
M
IN
N
EA
PO
LI
S-
SA
IN
T
PA
U
L
IA
P
AR
S M
IN
N
ES
O
TA
XX
-X
-X
XX
X
M
A R
C H
FI
LE
N
AM
E:
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
CERTIFIED FINAL DESIGN SUBMITTAL
3/
/2
1:
:1
PM
C :\U se rs
\b kg
\D oc um en ts \M y R ev it\
0_ Ar ch _B
G al la gh er 5S
B2 3.
rv t
G-003
U S
AC
E
LI
FE
S
AF
ET
Y
AN
D
C O
D E
R
EV
IE
W
P.
L
IT
TL
E
B.
G
AL
LA
G H
ER
B.
G
AL
LA
G H
ER
J.
IS
C H
M
AR
K D
E
SC
R
IP
TI
O
N D
A
TE
Qualified Fire Protection Engineer (QFPE) of Record
Architect-Engineer Design Certification of Fire Protection / Life Safety / Accessibility Code Requirements
Preparers of this document certify the accuracy, completeness, and incorporation of the
Aerial Port Facility - Minneapolis St-Paul ARS, Minnesota
Certified Final Submittal
Preparers of this docuemtn certify the accuracy and completeness of the Fire Protection and Life Safety features for this project indicated with the attached, completed signature forms.
all required fire protection, life safety, and accessibility features in this project for the indicated milestone review.
Signature Date
CERTIFICATION OF FIRE PROTECTION & LIFE SAFETY CODE REQUIREMENTS
T H
143A
143B
1' - 4"
6' - 4"6' - 4"
A2A2
G
F
55.5
AE303
B4
AE303
B1
6"
7' - 8"6' - 4"7' - 8"
6"
21' - 8"
M
AT
C H
LI
N
E
SE
E A
AE
OUTLINE OF
SUSPENDED
PARACHUTES
22' - 8"
DRYING
TOWER
C1
AE201
AE301
A1
F
E
D
55.5678
C.3
AE405
A1
AE303
B1
AE305
A2
5' - 0"
RIGGER
OFFICE
AERIAL
DELIVERY
VEHICLE
STO HIGH
BAY
8"3
130A
129B
129C
143B
128B
141A
128A
122A
E1
A4
A4
A4
A2
/8
1'
0" 3'
4"
2'
0"
2'
1/ 4"
16' - 0"20' - 6"29' - 2"6"
0"
0"
2'
8"
MATCHLINE
SEE A1 /
AE103
M
AT
C H
LI
N
E
SE
E A
AE
141D
1 1
VEHICLE
STO HIGH
BAY
12' - 2"
MOBILITY
STORAGE
139A
M2
141B
141C
9 9
(4)
(3) E1A2
127A
1/
4"
/4
/4
8'
3/ 8"
5'
0" 7'
8"
9' - 0"6' - 4"6' - 4"16' - 0"16' - 6"3' - 4"8" 2' - 8"
20' - 0"6' - 6"
21' - 8"
C3
AE404
C4
AE404
1/4" / 1'-0" 1/4" / 1'-0"
1/ 4"
1'
-0
SECTOR PLAN
AB
D C
1 2 3 4 5
A
B
D
SHEET ID
P ar kw ay
L an e, S ui te
Pe ac ht re e C or ne rs , G
A
Ph on e (6
) 3
-7
Fa x
(6
) 3
-7
SI
ZE
AN
SI
D
FI
LE
N
AM
E:
SU
BM
IT
TE
D B
Y:
C H
EC
K
ED
B
Y:
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
IS
SU
E D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
NORTH
US Army Corps of Engineers ® Louisville District
W
2Q R
-1 9-
D -X
XX
X
W
2Q R
-1 8-
D -0
PR
O
JE
C
T N
O
Q
JK
L1
P2
: 3
M
SP
A
ER
IA
L
PO
R
T
FA
C
IL
IT
Y
M
IN
N
EA
PO
LI
S-
SA
IN
T
PA
U
L
IA
P
AR
S M
IN
N
ES
O
TA
XX
-X
-X
XX
X
M
A R
C H
FI
LE
N
AM
E:
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
CERTIFIED FINAL DESIGN SUBMITTAL
3/
/2
4:
:3
PM
C :\U se rs
\b kg
\D oc um en ts \M y R ev it\
0_ Ar ch _B
G al la gh er 5S
B2 3.
rv t
AE105
FL
O
O R
P
LA
N -S
EC
TO
R D
P.
L
IT
TL
E
B.
G
AL
LA
G H
ER
B.
G
AL
LA
G H
ER
J.
IS
C H
SCALE: 1/8" = 1'-0"
FLOOR PLAN - SECTOR DC3
SCALE: = 1'-0"
0 8 168
1/8"
SCALE: 1/8" = 1'-0"
FLOOR PLAN - SECTOR DA1
BASE BID
BID OPTION: PARACHUTE DRYING
TOWER ADDITION
GENERAL NOTES
SHEET KEYNOTES
LEGEND
1. 4" DIA CONCRETE FILLED STEEL PIPE BOLLARDS.
2. FIXED METAL SHIP LADDER.
3. UTILITY SINK.
4. MECHANICAL EQUIPMENT.
5. 6X6 PREFINISHED DOWNSPOUT & SPLASH BLOCK -
GUTTER AND DOWNSPOUT COLOR TO MATCH
INSULATED METAL PANELS (IMWP1)
6. NOT USED
7. GRAVITY ROLLER SYSTEM - GFGI
8. PAINTED 1 1/2" OUTSIDE DIAMETER STEEL
GUARDRAIL.
9. 4'-0" REMOVABLE GUARDRAIL SECTIONS.
10. FIXED ALUMINUM MECHANICAL PLATFORM LADDER
11. 2-1/4" CLR INSIDE DIAMETER PIPE SLEEVES
EMBEDDED INTO CONCRETE SLAB - FINISH FLUSH
TO FLOOR - COORDINATE LOCATION WITH OWNER
12. BID OPTION: PREFINISHED MANUFACTURED
CANOPY
VISUAL LINE OF
AIR BARRIER
A. ALL INTERIOR PARTITIONS SHALL BE TYPE "A2" -
UNLESS NOTED OTHERWISE
B. ALL INTERIOR DIMENSIONS ARE FROM FACE OF
STUD TO FACE OF STUD OR FACE OF CMU OR
CONCRETE AS INDICATED - UNLESS NOTED
OTHERWISE.
C. CONTRACTORS ARE FREE TO USE ANY PRODUCT
WHICH MEETS THE GOVERNMENT'S MINIMUM
REQUIREMENTS AND NOT IN CONFLICT WITH OTHER
CONTRACT PROVISIONS. UNLESS INDICATED
OTHERWISE ON THE PLANS OR SPECIFICATIONS (E.G.
SOLE-SOURCE), ALL LISTED MANUFACTURERS ARE THE
BASIS OF DESIGN. FOR THESE BASIS OF DESIGN
PRODUCTS, OTHER MANUFACTURERS MAY BE
SUBSTITUTED AS LONG AS THE STANDARD OF QUALITY
AND CHARACTERISTICS OF THE SUBSITUTED
MANUFACTURER MEET OR EXCEED THE STANDARD OF
QUALITY AND CHARACTERISTICS OF THE BASIS OF
DESIGN.
NOTE: NOT
ALL USED
M
AR
K D
E
SC
R
IP
TI
O
N D
A
TE
RICHARD S.
JOHNSON
B
D
SHEET ID
P ar kw ay
L an e, S ui te
Pe ac ht re e C or ne rs , G
A
Ph on e (6
) 3
-7
Fa x
(6
) 3
-7
SI
ZE
AN
SI
D
FI
LE
N
AM
E:
SU
BM
IT
TE
D B
Y:
C H
EC
K
ED
B
Y:
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
IS
SU
E D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
US Army Corps of Engineers ® Louisville District
W
2Q R
-1 9-
D -X
XX
X
W
2Q R
-1 8-
D -0
PR
O
JE
C
T N
O
Q
JK
L1
P2
: 3
M
SP
A
ER
IA
L
PO
R
T
FA
C
IL
IT
Y
M
IN
N
EA
PO
LI
S-
SA
IN
T
PA
U
L
IA
P
AR
S M
IN
N
ES
O
TA
XX
-X
-X
XX
X
M
A R
C H
FI
LE
N
AM
E:
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
CERTIFIED FINAL DESIGN SUBMITTAL
3/
/2
1:
:1
PM
C :\U se rs
\b kg
\D oc um en ts \M y R ev it\
0_ Ar ch _B
G al la gh er 5S
B2 3.
rv t
G-003
U S
AC
E
LI
FE
S
AF
ET
Y
AN
D
C O
D E
R
EV
IE
W
P.
L
IT
TL
E
B.
G
AL
LA
G H
ER
B.
G
AL
LA
G H
ER
J.
IS
C H
M
AR
K D
E
SC
R
IP
TI
O
N D
A
TE
Qualified Fire Protection Engineer (QFPE) of Record
Architect-Engineer Design Certification of Fire Protection / Life Safety / Accessibility Code Requirements
Preparers of this document certify the accuracy, completeness, and incorporation of the
Aerial Port Facility - Minneapolis St-Paul ARS, Minnesota
Certified Final Submittal
Preparers of this docuemtn certify the accuracy and completeness of the Fire Protection and Life Safety features for this project indicated with the attached, completed signature forms.
all required fire protection, life safety, and accessibility features in this project for the indicated milestone review.
Signature Date
CERTIFICATION OF FIRE PROTECTION & LIFE SAFETY CODE REQUIREMENTS
OS
OS
OS
COVERED
LOADING
4 4 4
B
A
55.5678
AE502
A2
AE303
A1
TYPICAL CEILING LEGEND
2' x 2' CEILING GRID
GYP BD CEILING
2' x 4' FLUORESCENT FIXTURE - EMERGENCY
1' x 4' FLUORESCENT FIXTURE
RECESSED DOWNLIGHT
EXIT SIGNS
WALL MTD EXTERIOR LIGHT
SUPPLY AIR DIFFUSERS
RETURN AIR GRILLES
1' x 4' FLUORESCENT FIXTURE - EMERGENCY
2' x 4' FLUORESCENT
FIXTURE
2' x 4' FLUORESCENT FIXTURE - CLG MTD
1' x 4' FLUORESCENT FIXTURE - SUSPENDED
WALL MTD EXTERIOR LIGHT - EMERGENCY
RECESSED DOWNLIGHT - EMERGENCY
ACCESS DOORS
4' FLUORESCENT FIXTURE - STRIP
2' x 4' CEILING GRID
AE302
B1
AE302
B1
AE301
A1
AE301
A1
AE301
C1
AE301
C1
F
E
D
C
B
A
123455.5678
AE303
B1
AE303
B1
AE404
A3
AR TECHS(2)
VEST
1ST SGT
CMDR
PACKING/RIGGING
CSS
FIRE PUMP
AERIAL
DELIVERY
CONF
MEN
WOMEN
EAGLE CR 1
BREAK
ROOM
RIGGER
OFFICE
COPY
STO
CORR
MGR'S
VEHICLE
STO HIGH
BAY
LOAD
PLNG/ATOC
PROG/UDT/
UTM/SEC
TRAINING A
SPEC/HANDLING
CARGO
PAX
RAMP
VEST
TRAINING B
TRAINING C
CORR
OPS ASST
OPS
CORRIDOR
CORRIDOR
ELEC.
CORRIDOR
VEST
JAN.
114' - 0"
111' - 0"
111' - 0"
111' - 0"
111' - 0"
109' - 0"
108' - 0" 108' - 0"
NOTE: REFER SHEET
AE-107 FOR FULL HIGH -
BAY CEILING PLAN
BID OPTION: UNIT
ASSEMBLY PARTITIONS
BID OPTION: PREFINISHED
MANUFACTURED CANOPY
BID OPTION: PREFINISHED
MANUFACTURED CANOPY
112' - 0"
BASE BID: PREFINISHED
MANUFACTURED CANOPY
BASE BID: PREFINISHED
MANUFACTURED CANOPY
AE107
A3
G
F
55.5
AE303
B4
AE303
B1
DRYING
TOWER
(4) MOTORIZED SELF-
CLIMBING PARACHUTE
LIFT SYSTEMS WITH
WALL-MOUNTED NEMA
4 RATED CONTROL
PENDANTS AT FLOOR
LEVEL AND ALUMINUM
TRUSS ASSEMBLY
WITH MAXIMUM OF
L/600 DEFLECTION
SECTOR PLAN
AB
D C
1 2 3 4 5
A
B
D
SHEET ID
P ar kw ay
L an e, S ui te
Pe ac ht re e C or ne rs , G
A
Ph on e (6
) 3
-7
Fa x
(6
) 3
-7
SI
ZE
AN
SI
D
FI
LE
N
AM
E:
SU
BM
IT
TE
D B
Y:
C H
EC
K
ED
B
Y:
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
IS
SU
E D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
NORTH
US Army Corps of Engineers ® Louisville District
W
2Q R
-1 9-
D -X
XX
X
W
2Q R
-1 8-
D -0
PR
O
JE
C
T N
O
Q
JK
L1
P2
: 3
M
SP
A
ER
IA
L
PO
R
T
FA
C
IL
IT
Y
M
IN
N
EA
PO
LI
S-
SA
IN
T
PA
U
L
IA
P
AR
S M
IN
N
ES
O
TA
XX
-X
-X
XX
X
M
A R
C H
FI
LE
N
AM
E:
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
CERTIFIED FINAL DESIGN SUBMITTAL
3/
/2
4:
:5
PM
C :\U se rs
\b kg
\D oc um en ts \M y R ev it\
0_ Ar ch _B
G al la gh er 5S
B2 3.
rv t
AE106
R
EF
LE
C
TE
D
C
EI
LI
N
G P
LA
N
P.
L
IT
TL
E
B.
G
AL
LA
G H
ER
B.
G
AL
LA
G H
ER
J.
IS
C H
SCALE: 3/32" = 1'-0"
REFLECTED CEILING PLANA4
SHEET KEYNOTES
1. NOTE: ALL CEILINGS AT 9'-0" A.F.F. UNLESS
OTHERWISE NOTED.
2. CABLE TRAY
3. NOT USED
4. 6" x 6" PREFINISHED METAL GUTTER AND
DOWNSPOUT - COLOR TO MATCH (IMWP1)
5. PRE-MANUFACTURED CANOPY SYSTEM
6. ROOF ACCESS HATCH
7. FIXED ALUMINUM LADDER
8. BID OPTION: 5-TON BRIDGE CRANE
SCALE: = 1'-0"3/32"
0 8 16 248
SCALE: 3/32" = 1'-0"
REFLECTED CEILING PLANA1
SCALE: 3/32" = 1'-0"
REF. CEILING PLAND4
BASE BID
BID OPTION: COVERED LOADING AREA
CANOPY ADDITION
BID OPTION: PARACHUTE DRYING
TOWER ADDITION
M
AR
K D
E
SC
R
IP
TI
O
N D
A
TE
RICHARD S.
JOHNSON
AERIAL PORT FACILITY (P2: 331663) CORRECTED FINAL SUBMITTAL
MINNEAPOLIS-ST. PAUL ARS, MINNESOTA 19 MARCH 2021
SECTION 09 06 00
SCHEDULES FOR FINISHES
05/09
PART 1 GENERAL
1.1 SUMMARY
This section covers only the color of exterior and interior materials and products that are exposed to view in the finished construction. The word "color", as used herein, includes surface color and pattern. Requirements for quality, product specifications, and method of installation are covered in other appropriate sections of the specifications. Specific locations where the various materials are required are shown on the drawings if not identified in this specification. Items not designated for color in this section may be specified in other sections. When color is not designated for items, propose a color for approval.
PART 2 PRODUCTS
2.1 COLOR SCHEDULE
The color schedule information provided in the following paragraphs lists the colors, patterns and textures required for exterior and interior finishes, including both factory applied and field applied colors. Where color is shown as being specific to one manufacturer, an equivalent color by another manufacturer may be submitted for approval. Manufacturers and materials specified are not intended to limit the selection of equal colors from other manufacturers. In the case of difference between the drawings and specifications, colors identified in this specification govern.
2.2 EXTERIOR FINISHES
Reference drawings for manufacturer and color information.
2.2.1 Exterior Walls
Exterior wall colors apply to exterior wall surfaces including recesses at entrances and projecting vestibules. When applicable, paint conduit to closely match the adjacent surface color. Provide wall colors to match the colors listed below.
2.2.1.1 Brick
(MV1): Minnesota Brick, Color to match: "Wellington" Signature Series
2.2.1.2 Mortar
Color to match: "Standard Gray"
2.2.1.3 Precast Concrete Sills
(PC1): Federal Standard 595B, Color to match: #2385Dark Buff Limestone
SECTION 09 06 00 Page 1
MINNEAPOLIS-ST. PAUL ARS, MINNESOTA 22 JANUARY 2021
2.2.1.4 Insulated Metal Wall Panels, Hardware, and Associated Trim
(IMWP1): Centria, Color to match: #9967 XL Pewter
2.2.1.5 Glass and Glazing
Vitro Architectural Glass, Color to match: Solar Bronze
2.2.2 Exterior Trim
Provide exterior trim to match the colors listed below.
2.2.2.1 Steel Doors and Door Frames
(PT2): Sherwin Williams, Color to match: SW7642 Pavestone (Semi Gloss)
2.2.2.2 Storefront Aluminum Doors
Color to match: Clear Anodized
2.2.2.3 Storefront Aluminum Frames
Color to match: Clear Anodized
2.2.2.4 Manufactured Canopy
Color to match: Clear anodized
2.2.2.5 Overhangs including exposed steel purlins, deck and exposed Metal Building columns at COVERED LOADING #143
Color match: IMWP1
2.2.2.6 Downspouts and Gutters
Color match: IMWP1
2.2.2.7 Louvers
Color to match: adjacent material in color.
2.2.2.8 Flashings and trims
Color match: IMWP1
2.2.2.9 Caulking and Sealants
Color to match adjacent material in color.
2.2.2.10 Bollards
Color to match: Safety Yellow
2.2.2.11 Signage
TBD
SECTION 09 06 00 Page 2
2.2.2.12 Sun Shades (part of the Aluminum Storefront Frame system
Color to match: clear anodized
2.2.2.13 Control Joints
Color to match: Adjacent material in color.
2.2.3 Exterior Roof
Apply roof color to exterior roof surfaces including sheet metal flashings and copings, snow guards, mechanical units, mechanical penthouses, roof trim, pipes, conduits, electrical appurtenances, and similar items.
Provide roof color to match the colors listed below.
2.2.3.1 Metal
(SSMR1) Centri, Color to match: #9967 XL Pewter
2.2.3.2 Penetrations
Match roof in color.
2.3 INTERIOR FINISHES
2.3.1 Interior Floor Finishes
Provide flooring materials to match the colors listed below.
2.3.1.1 Carpet Tile
Bid Option - CPT1:Bentley Drawing Room / Redacted 8RF23 / Document 801532, 18" x 36", NexStep Cushion Tile 8RF230AA0T, Ashlar Installation; Basis of Design
2.3.1.2 Luxury Vinyl Tile
Bid Option - LVT1: Mannington - Spacia / Abstract / Linen Weave SS5A3800,17.7" x 17.7", Monolithic Installation; Basis of Design
2.3.1.3 Static-Dissipative Vinyl Tile
Bid Option - SDT1: Tarkett - iQ Granit SD / Granit Raw Ivory , 12" x 12", Monolithic Installation; Basis of Design
2.3.1.4 Porcelain Tile
Bid Option - PRC1: Crossville Studios - Color Blox / Slinky A1103.11224UPS, Unpolished, 12" x 24"; Basis of Design
2.3.1.5 Grout
Bid Option - GR1: Mapei - Epoxy, 09 Gray; Basis of Design
2.3.1.6 Transition Strips
Bid Option - Rubber: Tarkett - 32 Pebble; Basis of Design Bid Option - Aluminum: Schluter - Clear Anodized; Basis of Design
SECTION 09 06 00 Page 3
2.3.1.7 Entrance Flooring
Bid Option - EF1: Milliken and Company - Obex Tile / Cutx / Fizz / Mocha FZC145, 19.7" x 19.7"; Basis of Design
2.3.1.8 Concrete Sealed
CONC1: Clear Penetrating Sealer; Basis of Design
2.3.1.9 Industrial Floor Coating
Bid Option - EP1: Epoxy Flooring: StonHard - StonClad / Mushroom;
Basis of Design
2.3.2 Interior Base Finishes
Provide base materials to match the colors listed below.
2.3.2.1 Resilient Base and Moldings
RB1: Tarkett - Traditional Vinyl 1/8", 32 Pebble, 4" High Cove Base; Basis of Design
2.3.2.2 Porcelain Tile
PRCB1: Crossville - Color Blox / Slinky / Cove Base A1103.10612CBS, 6" x 12"; Basis of Design
2.3.2.3 Grout
GR1: Mapei - Epoxy, 09 Gray; Basis of Design
2.3.2.4 Integral Cove Base
Bid Option - EP1: Epoxy Flooring - StonHard - StonClad / Mushroom;
Basis of Design
2.3.3 Interior Wall Finishes
Apply interior wall color to the entire wall surface, including reveals, vertical furred spaces and columns, grilles, diffusers, electrical and access panels, and piping and conduit adjacent to wall surfaces unless otherwise specified. Paint items not specified in other paragraphs to match adjacent wall surface. Provide wall materials to match the colors listed below.
2.3.3.1 Paint
PT1: Sherwin Williams - SW7015 Repose Gray, Eggshell; Basis of Design
2.3.3.2 Fabric Wall Covering on Folding Wall Partition
FWC1: Maharam - Tek-Wall 1002, 399594 / 011 Vase; Basis of Design
2.3.3.3 Porcelain Tile
PRC1: Crossville Studios - Color Blox / Slinky A1103.11224UPS, Unpolished, 12" x 24"; Basis of Design
SECTION 09 06 00 Page 4
2.3.3.4 Grout
GR1: Mapei - Epoxy, 09 Gray; Basis of Design
2.3.3.5 Exposed Structural Columns
PT3: Sherwin Williams - SW7005 Pure White, Flat; Basis of Design
2.3.4 Interior Ceiling Finishes
Apply ceiling colors to ceiling surfaces including soffits, furred down areas, grilles, diffusers, registers, and access panels. In addition, apply ceiling color to joists, underside of roof deck, and conduit and piping where joists and deck are exposed and required to be painted.
Provide ceiling materials to match the colors listed below.
2.3.4.1 Acoustical Tile and Grid
ACP1: USG – Mars Acoustical Panel 86985, White, 24” x 24” x 3/4”, Fine Line Beveled; Basis of Design ACP1 Grid: USG - Donn Brand Centricitee DXT/DXLT 9/16", Acoustical Suspension System, White; Basis of Design
2.3.4.2 Paint (Ceilings)
PT3: Sherwin Williams - SW7005 Pure White, Flat; Basis of Design
2.3.4.3 Paint (Soffits)
PT3: Sherwin Williams - SW7005 Pure White, Flat; Basis of Design
2.3.4.4 Metal Deck
PT3: Sherwin Williams - SW7005 Pure White, Flat; Basis of Design
2.3.4.5 Structural Framing
PT3: Sherwin Williams - SW7005 Pure White, Flat; Basis of Design
2.3.5 Interior Trim
Provide interior trim to match the colors listed below.
2.3.5.1 Steel Doors
8439935
PT2: Sherwin Williams - SW7642 Pavestone, Semi Gloss; Basis of Design
2.3.5.2 Steel Door Frames
PT2: Sherwin Williams - SW7642 Pavestone, Semi Gloss; Basis of Design
2.3.5.3 Steel Windows (mullion, muntin, sash, trim, and stool)
PT2: Sherwin Williams - SW7642 Pavestone, Semi Gloss; Basis of Design
SECTION 09 06 00 Page 5
2.3.5.4 Wood Stain
ST1: Sherwin Williams Minwax, Toasted Barrel MW405; Basis of Design
2.3.5.5 Fire Extinguisher Cabinets
White
2.3.5.6 Handrails
PT2: Sherwin Williams - SW7642 Pavestone, Semi Gloss; Basis of Design
2.3.5.7 Guardrails
PT2: Sherwin Williams - SW7642 Pavestone, Semi Gloss; Basis of Design
2.3.5.8 Ladders
PT2: Sherwin Williams - SW7642 Pavestone, Semi Gloss; Basis of Design
2.3.5.9 Metal Stairs; includes risersand underside of stairs only
PT2: Sherwin Williams - SW7642 Pavestone, Semi Gloss; Basis of Design
2.3.5.10 Exposed Ductwork
PT3: Sherwin Williams - SW7005 Pure White, Flat; Basis of Design
2.3.6 Interior Window Treatment
Provide window treatments to match the colors listed below.
2.3.6.1 Window Shades
RS1: Mecho Shade Systems - Soho 1600 Series Screens / 1617 Onyx Tweed, Visible Light Transmittance 3%, Manual Operation; Basis of Design
2.3.7 Interior Miscellaneous
Provide miscellaneous items to match the colors listed below.
2.3.7.1 Toilet Partitions and Urinal Screens
Stainless Steel
2.3.7.2 Plastic Laminate
PLAM1: Wilsonart - Phantom Cocoa 8213K-28, Gloss Line Finish with Aeon; Basis of Design
2.3.7.3 Solid Surfacing Material
SSM1: Wilsonart - Dusk Ice 9203CE; Basis of Design
SECTION 09 06 00 Page 6
2.3.7.4 Window Sills (Solid Surface)
SSM1: Wilsonart - Dusk Ice 9203CE; Basis of Design
2.3.7.5 Corner Guards
CG1: Constuction Specialties - VA-034N / 314 Ozark - 3/4" Legs, .060" Thick Acrovyn, 4' Height; Basis of Design
2.3.7.6 Protective Wall Covering/Panel
FRP1: Marlite - Standard FRP, P100 White Pebbled; Basis of Design
2.3.7.7 Signage Message Color
SG1: Systems 2|90 - Slide Modular - 708 Soft White; Basis of Design
2.3.7.8 Signage Background Color
SG2: Systems 2|90 - Slide Modular - 705 Medium Gray; Basis of Design
2.3.7.9 Siganage Frame Color
SG3: Slide Modular - 101 Satin Natural; Basis of Design
2.3.7.10 Wall Switch Handles and Standard Receptacle Bodies
White
2.3.7.11 Electrical Device Cover Plates
White
2.3.7.12 Electrical Panels
Painted to Match Adjacent Surface
PART 3 EXECUTION
Not Used
-- End of Section --
SECTION 09 06 00 Page 7
INTERIOR FINISHES
Aerial Port Facility 100004 (QJKL ) Minneapolis - Saint Paul ARS, Minnesota SID Color Boards - Structural Interior Design
CPT1: Carpet Tile
Installation PhotoRB1: Rubber Base
Aerial Port Facility 100004(QJKL ) Minneapolis - Saint Paul ARS, Minnesota SID Color Boards - Structural Interior Design
LVT Luxury Vinyl Tile1:
Installation Photo
RB1: Rubber Base
PT3: Ceiling Paint
PT1: Field Paint
PT2: oor / Door Frame D Paint
Locker: Charcoal Gray
Aerial Port Facility (QJKL100004) Minneapolis - Saint Paul ARS, Minnesota SID Color Boards - Structural Interior Design
ACP Acoustical Ceiling Panel1:
Installation PhotoPT3: Ceiling Paint
Aerial Port Facility (QJKL100004) Minneapolis - Saint Paul ARS, Minnesota SID Color Boards - Structural Interior Design
PRC1/PRCB1: Porcelain Tile (Field) and Base
PLAM1: Plastic Laminate
GR1: Grout
SSM1: Solid Surface Material
PT1: Field Paint
Aerial Port 100004)Facility (QJKL Minneapolis - Saint Paul ARS, Minnesota SID Color Boards - Structural Interior Design
CG1: Corner Guard
SG1: Signage Message SG3: Signage FrameSG2: Signage Background
RS1: Roller ShadeSDT1 Static Dissipative Tile:
FRP1: Fiberglass Reinforced Panel
EF Entrance Flooring1:
B
D
SHEET ID
P ar kw ay
L an e, S ui te
Pe ac ht re e C or ne rs , G
A
Ph on e (6
) 3
-7
Fa x
(6
) 3
-7
SI
ZE
AN
SI
D
FI
LE
N
AM
E:
SU
BM
IT
TE
D B
Y:
C H
EC
K
ED
B
Y:
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
IS
SU
E D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
US Army Corps of Engineers ® Louisville District
W
2Q R
-1 9-
D -X
XX
X
W
2Q R
-1 8-
D -0
PR
O
JE
C
T N
O
Q
JK
L1
P2
: 3
M
SP
A
ER
IA
L
PO
R
T
FA
C
IL
IT
Y
M
IN
N
EA
PO
LI
S-
SA
IN
T
PA
U
L
IA
P
AR
S M
IN
N
ES
O
TA
XX
-X
-X
XX
X
M
A R
C H
FI
LE
N
AM
E:
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
CERTIFIED FINAL DESIGN SUBMITTAL
3/
/2
1:
:1
PM
C :\U se rs
\b kg
\D oc um en ts \M y R ev it\
0_ Ar ch _B
G al la gh er 5S
B2 3.
rv t
G-003
U S
AC
E
LI
FE
S
AF
ET
Y
AN
D
C O
D E
R
EV
IE
W
P.
L
IT
TL
E
B.
G
AL
LA
G H
ER
B.
G
AL
LA
G H
ER
J.
IS
C H
M
AR
K D
E
SC
R
IP
TI
O
N D
A
TE
Qualified Fire Protection Engineer (QFPE) of Record
Architect-Engineer Design Certification of Fire Protection / Life Safety / Accessibility Code Requirements
Preparers of this document certify the accuracy, completeness, and incorporation of the
Aerial Port Facility - Minneapolis St-Paul ARS, Minnesota
Certified Final Submittal
Preparers of this docuemtn certify the accuracy and completeness of the Fire Protection and Life Safety features for this project indicated with the attached, completed signature forms.
all required fire protection, life safety, and accessibility features in this project for the indicated milestone review.
Signature Date
CERTIFICATION OF FIRE PROTECTION & LIFE SAFETY CODE REQUIREMENTS
FINISH NOTES
A. MANUFACTURERS REFERENCED ARE INTENDED TO
ESTABLISH DESIGN INTENT ONLY AND ARE NOT
INTENDED TO LIMIT SELECTIONS FROM OTHER
MANUFACTURERS. WHEN ALTERNATE SELECTIONS
ARE SUBMITTED, SUBMITTAL SHALL INCLUDE
COLOR SAMPLES OF MATERIALS FOR COMPARISON.
B. REFER TO SPECIFICATIONS 09 06 00 FOR FINISHES
AND SPECIAL ITEMS.
C. ALL DOOR FRAMES ARE TO BE PAINTED, (PT2)
U.N.O.
D. REFER TO SHEETS IN110 FOR FLOOR FINISH
PATTERNS.
E. ALL WINDOWS SHALL RECEIVE ROLLER SHADES,
(RS1) U.N.O.
F. ALL DEMOUNTABLE WALL PANEL (DWP) ARE
INCLUDED IN THE FURNITURE, FIXTURES, AND
EQUIPMENT PACKAGE. THE PARTITIONS SHALL
COME WITH THE MANUFACTURER'S FACTORY
FINISH AS SPECIFIED IN THE FURNITURE, FIXTURES,
AND EQUIPMENT PACKAGE.
G. REFER TO BID SCHEDULE FOR FLOOR FINISH BID
OPTION.
FINISH SCHEDULE NOTES
1. ALL EXPOSED CEILINGS & STRUCTURES TO BE
PAINTED, (PT3).
2. ALL WALLS WITH AREAS OF EXPOSED GYP BD ARE
TO BE PAINTED WITH EPOXY PAINT
3. (FRP1) AT 6'-0" ABOVE FLOOR FINISH LEVEL WITH
EPOXY PAINT ABOVE.
4. WALLS WITH AREAS OF EXPOSED GYP BD ARE TO
RECEIVE RUBBER BASE. DEMOUNTABLE WALL
PARTITIONS ARE TO RECEIVE NO BASE.
5. ALL FLOORING FINISHES LISTED ON FINISH
SCHEDULE ARE BID OPTIONS.
FINISH LEGEND
ACP ACOUSTIC CEILING PANEL
CONC CONCRETE
CPT CARPET TILE
DWP DEMOUNTABLE WALL PANEL (FF+E)
EF ENTRANCE FLOORING
EXP EXPOSED TO STRUCTURE
FRP FIBERGLASS REINFORCED PANEL
GL GLASS TILE
GYP BD GYPSUM BOARD
LVT LUXURY VINYL TILE
PRC PORCELAIN TILE
PRCB PORCELAIN TILE BASE
PT PAINT
RB RESILIENT BASE
SDT STATIC DISSIPATIVE TILE
LP MBS INTERIOR LINER PANEL
TRANSITION LEGEND
FLOORING MATERIAL
CARPET TILE (CPT) TO LUXURY
VINYL TILE (LVT)
TRANSITION STYLE FINISH/COLOR NOTES
CARPET TILE (CPT) TO SEALED
CONCRETE (SC)
LUXURY VINYL TILE (LVT) TO
SEALED CONCRETE (SC)
INSTALL LEG UNDER
CARPET
SCHLUTER, RENO-U ANODIZED ALUMINUM
JOHNSONITE, CTA-32-J 32 PEBBLE
JOHNSONITE, SRA-32-B 32 PEBBLE
1 2 3 4 5
A
B
D
SHEET ID
P ar kw ay
L an e, S ui te
Pe ac ht re e C or ne rs , G
A
Ph on e (6
) 3
-7
Fa x
(6
) 3
-7
SI
ZE
AN
SI
D
FI
LE
N
AM
E:
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
IS
SU
E D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M B
ER
US Army Corps of Engineers ® Louisville District
W
2Q R
-1 9-
D -X
XX
X
W
2Q R
-1 8-
D -0
PR
O
JE
C
T N
O
Q
JK
L1
P2
: 3
M
SP
A
ER
IA
L
PO
R
T
FA
C
IL
IT
Y
M
IN
N
EA
PO
LI
S-
SA
IN
T
PA
U
L
IA
P
AR
S M
IN
N
ES
O
TA
XX
-X
-X
XX
X
M
A R
C H
FI
LE
N
AM
E:
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
E
ER
S
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
CERTIFIED FINAL DESIGN SUBMITTAL
3/
/2
6:
:5
AM
C :\U se rs
\tb \D oc um en ts
\M y
R ev it\
0_
Ar ch
_T Br un ga rd .rv t
AE601
R O
O M
F
IN
IS
H
S C
H
ED
U
LE
P.
L
IT
TL
E
B.
G
AL
LA
G H
ER
B.
G
AL
LA
G H
ER
J.
IS
C H
ROOM FINISH SCHEDULE
ROOM
NUMBER. ROOM NAME
FLOOR
FINISH
BASE
FINISH
WALL FINISHES CEILING
FINISH
CEILING
HEIGHT NOTESNORTH SOUTH EAST WEST
101 VEST EF1 RB1 PT1 PT1 PT1 PT1 ACP1 9' 5
102 AR TECHS(2) CPT1 RB1 PT1 DWP1 PT1 PT1 ACP1 9' 5
103 1ST SGT CPT1 RB1 DWP1 DWP1 PT1 PT1 ACP1 9' 5
104 CMDR CPT1 RB1 DWP1 DWP1 PT1 PT1 ACP1 9' 5
105 CORR CONC1 RB1 PT1 PT1 PT1 PT1 ACP1 9'
106 OPS ASST CPT1 RB1 DWP1 DWP1 PT1 PT1 ACP1 9' 5
107 OPS CPT1 RB1 DWP1 PT1 PT1 PT1 ACP1 9' 5
108 BREAK ROOM LVT1 RB1 PT1 PT1 PT1 PT1 ACP1 9' 5
109 VEST EF1 RB1 PT1 PT1 PT1 PT1 ACP1 9' 5
110 PROG/UDT/ UTM/SEC CPT1 RB1 PT1 DWP1 PT1 PT1 ACP1 9' 5
111 LOAD PLNG/ATOC CPT1 RB1 PT1/DWP1 PT1 PT1 PT1 ACP1 9' 5
112 CORRIDOR CONC1 RB1 - - PT1 PT1 PT1 ACP1 9'
113 TRAINING A CPT1 RB1 - - PT1 PT1 PT1 ACP1 11' 5
114 TRAINING B CPT1 RB1 - - - - PT1 PT1 ACP1 11' 5
115 TRAINING C CPT1 RB1 PT1 - - PT1 PT1 ACP1 11' 5
116 VEST EF1 RB1 PT1 PT1 PT1 PT1 ACP1 9' 5
117 CORR CONC1 RB1 - - PT1 PT1 PT1 ACP1 9'
118 SPEC/HANDLING CPT1 RB1 DWP1 PT1 PT1 PT1 ACP1 9' 5
119 CARGO CPT1 RB1 DWP1 DWP1 PT1 PT1 ACP1 9' 5
120 PAX CPT1 RB1 DWP1 DWP1 PT1 PT1 ACP1 9' 5
121 RAMP CPT1 RB1 PT1 DWP1 PT1 PT1 ACP1 9' 5
122 CORRIDOR CONC1 RB1 PT1 PT1 PT1 PT1 ACP1 9'
123 CONF CPT1 RB1 PT1 PT1 PT1 PT1 ACP1 9' 5
124 JAN. CONC1 RB1 FRP1/PT1 FRP1/PT1 FRP1/PT1 FRP1/PT1 EXP/PT3 EXP 3
125 WOMEN PRC1 PRCB1 PRC1 / PT1 PT1 PRC1/PT1 PRC1/PT1 GYP BD, PT3 8' 2,5
126 MEN PRC1 PRCB1 PT1 PRC1 / PT1 PRC1/PT1 PRC1/PT1 GYP BD, PT3 8' 2,5
127 EAGLE CR 1 CPT1 RB1 PT1 PT1 PT1 PT1 ACP1 9' 5
128 RIGGER OFFICE CPT1 RB1 PT1 PT1 PT1 PT1 ACP1 9' 5
129 PACKING/RIGGING EP1 RB1 PT1 PT1 PT1 PT1 ACP1 14'
130 CORRIDOR CONC1 RB1 PT1 PT1 PT1 PT1 ACP1 9'
131 COPY CONC1 RB1 PT1 - - PT1 PT1 ACP1 9'
132 CSS CPT1 RB1 PT1 PT1 PT1/DWP1 PT1 ACP1 9' 5
133 STO CONC1 RB1 PT1 PT1 PT1 PT1 ACP1 9'
134 MGR'S CPT1 RB1 PT1 PT1 PT1 PT1/DWP1 ACP1 9' 5
135 FIRE PUMP CONC1 RB1 PT1 PT1 PT1 PT1 EXP/PT3 EXP
136 ELEC. CONC1 RB1 PT1 PT1 PT1 PT1 EXP/PT3 EXP 1
137 COMM. SDT1 RB1 PT1 PT1 PT1 PT1 EXP/PT3 EXP 1
138 RIGGING STORAGE CONC1 RB1 PT1 PT1 PT1 PT1 EXP/PT3 EXP
139 MOBILITY STORAGE CONC1 RB1 PT1 PT1 PT1 PT1 ACP1 11'/12'
140 AERIAL DELIVERY CONC1 RB1 LP1 LP1 PT1 -- EXP/PT3 EXP
141 VEHICLE STO HIGH BAY CONC1 RB1 LP1 LP1 -- LP1 EXP/PT3 EXP
142 COVERED LOADING -- -- -- -- -- -- EXP/PT3 EXP --
143 DRYING TOWER CONC1 RB1 PT1 PT1 PT1 PT1 EXP/PT3 EXP 1
144 MECH PLATFORM -- -- -- -- -- -- -- --
145 MECH CONC1 RB1 PT1 PT1 PT1 PT1 EXP/PT3 EXP 1
INTERIOR FINISH LEGEND
CODE MATERIAL MANUFACTURER PATTERN / COLOR SIZE NOTES
BASE MATERIAL
EP1 EPOXY INTEGRAL
BASE
STONHARD; BASIS OF
DESIGN
STONCLAD / MUSHROOM 4"H BID OPTION
PRCB1 PORCELAIN TILE CROSSVILLE STUDIOS;
BASIS OF DESIGN
COLOR BLOX / SLINKY / COVE BASE /
A1103.10612CBS
6" X 12"
RB1 RUBBER BASE TARKETT; BASIS OF DESIGN TRADITIONAL VINYL 1/8" / 32 PEBBLE /
COVE
4" H
CEILING MATERIAL
ACP1 ACOUSTICAL CEILING
PANEL
USG; BASIS OF DESIGN MARS ACOUSTICAL PANEL 86985 24" X 24"
ACP1 -
GRID
ACOUSTICAL
SUSPENSION SYSTEM
USG; BASIS OF DESIGN DONN BRAND CENTRICITEE DXT/DXLT 9/16"
FLOOR MATERIAL
CONC1 SEALED CONCRETE -- CLEAR PENETRATING SEALER --
CPT1 CARPET TILE BENTLEY; BASIS OF DESIGN DRAWING ROOM / REDACTED 8RF23 /
DOCUMENT 801532
18" X 36" ASHLAR
INSTALLATION
EF1 ENTRANCE FLOORING MILLIKEN AND COMPANY;
BASIS OF DESIGN
OBEX TILE / CUTX / FIZZ / MOCHA FZC145 19.7" X
19.7"
MONOLITHIC
INSTALLATION
EP1 EPOXY FLOORING STONHARD; BASIS OF
DESIGN
STONCLAD / MUSHROOM -- BID OPTION
LVT1 LUXURY VINYL TILE MANNINGTON; BASIS OF
DESIGN
SPACIA / ABTRACT / LINEN WEAVE
SS5A3800
17.7" X 17.7"
MONOLITHIC
INSTALLATION
PRC1 PORCELAIN TILE CROSSVILLE STUDIOS;
BASIS OF DESIGN
COLOR BLOX / SLINKY A1103.11224UPS 12" X 24"
MISCELLANEOUS MATERIAL
DWP1 DEMOUNTABLE WALL
PARTITION
DIRTT MDF PAINT: COLOR TO MATCH SW7015,
FRAME:CLAY
FF&E
FRP1 FIBERGLASS
REINFORCED PANEL
MARLITE; BASIS OF DESIGN STANDARD FRP, P100 WHITE PEBBLED --
GR1 GROUT MAPEI; BASIS OF DESIGN 09 GRAY -- EPOXY
PLAM1 PLASTIC LAMINATE WILSONART; BASIS OF
DESIGN
PHANTOM COCOA 8213K-28 / GLOSS
LINE FINISH WITH AEON
RS1 ROLLER SHADES MECHO SHADE SYSTEMS;
BASIS OF DESIGN
SOHO 1600 SERIES SCREENS, 1617
ONYX TWEED, 3% OPEN
-- MANUAL
OPERATION
SG1 SIGNAGE MESSAGE SYSTEMS 2|90; BASIS OF
DESIGN
708 SOFT WHITE -- SLIDE MODULAR
SYSTEM
SG2 SIGNAGE
BACKGROUND
SYSTEMS 2|90; BASIS OF
DESIGN
705 MEDIUM GRAY -- SLIDE MODULAR
SYSTEM
SG3 SIGNAGE FRAME SYSTEMS 2|90; BASIS OF
DESIGN
101 SATIN NATURAL -- SLIDE MODULAR
SYSTEM
SSM1 SOLID SURFACE
MATERIAL
WILSONART; BASIS OF
DESIGN
DUSK ICE 9203CE --
PAINT
PT1 PAINT SHERWIN WILLIAMS; BASIS
OF DESIGN
SW 7015 REPOSE GRAY / EGGSHELL
FINISH
-- FIELD PAINT
PT2 PAINT SHERWIN WILLIAMS; BASIS
OF DESIGN
SW 7642 PAVESTONE / SEMI GLOSS -- DOORS / DOOR
FRAMES
PT3 PAINT SHERWIN WILLIAMS; BASIS
OF DESIGN
SW 7005 PURE WHITE / FLAT FINISH -- CEILING PAINT
WALL MATERIAL
FWC1 FABRIC
WALLCOVERING
MAHARAM; BASIS OF
DESIGN
TEK-WALL 1002, 399594 / 011 VASE -- BID OPTION -
FOLDING WALL
PARTITION
PRC1 PORCELAIN TILE CROSSVILLE STUDIOS;
BASIS OF DESIGN
COLOR BLOX / SLINKY A1103.11224UPS 12" X 24"
M
AR
K D
E
SC
R
IP
TI
O
N D
A
TE
RICHARD S.
JOHNSON
B
D
SHEET ID
P ar kw ay
L an e, Su ite
Pe ac ht re e
C or ne rs
,G A
Ph on e
(6
)3
-7
Fa x (6
) 3
-7
SI
ZE
AN
SI
D
FI
LE
N
AM
E:
SU
BM
IT
TE
D B
Y:
C H
EC
K
ED
B
Y:
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
IS
SU
E D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
US Army Corps of Engineers ® Louisville District
W
2Q R
-1 9-
D -X
XX
X
W
2Q R
-1 8-
D -0
PR
O
JE
C
T N
O
Q
JK
L1
P2
: 3
M
SP
A
ER
IA
L
PO
R
T
FA
C
IL
IT
Y
M
IN
N
EA
PO
LI
S-
SA
IN
T
PA
U
L
IA
P
AR
S M
IN
N
ES
O
TA
XX
-X
-X
XX
X
M
A R
C H
FI
LE
N
AM
E:
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
CERTIFIED FINAL DESIGN SUBMITTAL
3/
/2
1:
:1
PM
C :\U se rs
\b kg
\D oc um en ts \M y R ev it\
0_ Ar ch _B
G al la gh er 5S
B2 3.
rv t
G-003
U S
AC
E
LI
FE
S
AF
ET
Y
AN
D
C O
D E
R
EV
IE
W
P.
L
IT
TL
E
B.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .