W912QR21R0008_Specs_PhaseB_Vol3_110000_Part2-0008.pdf

PDF 1011 KB Posted

Attached to
Construction of the VA Medical Center (VAMC) Project in Louisville, KY
Solicitation number
W912QR21R0008
Issued by

About this file

This document contains specifications for a high temperature rack conveyor electric commercial dishwashing machine and the related federal contract opportunity to construct a new VA Medical Center in Louisville, KY. The dishwashing machine specifications provide details on the CL64eN-BAS electric tank heat model including 342 racks per hour capacity, top mounted computer controls, and options such as vent hoods, booster heaters, and side loaders. The federal contract opportunity is for the construction of a new 104 bed hospital, parking structures, campus infrastructure and associated site work for approximately $705 million. Proposals are due in December 2020 and will be evaluated on past performance, management plan, schedule, small business participation, and price using a best value tradeoff process. The selected contractor will have 1,554 days to complete the project.

View the file

Other files

File Type Posted
W912QR21R0008_Plans_PhaseA-0008.pdf PDF
W912QR21R0008_Specs_PhaseB_Vol3_110601-0008.xlsx XLSX spreadsheet
W912QR21R0008_Plans_PhaseB-0008.pdf PDF
W912QR21R0008_Specs_PhaseA-0008.pdf PDF
W912QR21R0008_CT-0008.pdf PDF
W912QR21R0008_Specs_PhaseB_Vol3_110601-0008.pdf PDF
W912QR21R0008_Specs_PhaseB_Vol3_110000_Part1-0008.pdf PDF
W912QR21R0008_Specs_PhaseB-0008.pdf PDF
W912QR21R0008_Specs_PhaseB_Vol3_110601-0007..xlsx XLSX spreadsheet
W912QR21R0008_Specs_PhaseA-0007.pdf PDF
W912QR21R0008_Specs_CT-0007.pdf PDF
W912QR21R0008_Specs_PhaseB_Vol3_110601-0007.pdf PDF
W912QR21R0008_Plans_PhaseB_Part2-0007.pdf PDF
W912QR21R0008_Plans_PhaseA-0007.pdf PDF
W912QR21R0008_Plans_PhaseB_Part1-0007.pdf PDF
W912QR21R0008_Specs_PhaseB-0007.pdf PDF
W912QR21R0008_Specs_PhaseB_Vol3_110000_Part1-0007.pdf PDF
W912QR21R0008-0006.pdf PDF
W912QR21R0008_Plans-0005.pdf PDF
W912QR21R0008_Specs-0005.pdf PDF
W912QR21R0008_Specs_PhaseB_Vol3_110601-0005.xlsx XLSX spreadsheet
W912QR21R0008_Specs_PhaseB_Vol3_110000_Part2-0004.pdf PDF
W912QR21R0008_Plans-0004.pdf PDF
W912QR21R0008_Specs-0004.pdf PDF
W912QR21R0008_Specs_PhaseB_Vol3_110000_Part1-0004.pdf PDF
W912QR21R0008_Specs_PhaseB_Vol3_110601-0003.xlsx XLSX spreadsheet
W912QR21R0008_Specs-0003.pdf PDF
W912QR21R0008_Plans-0003.pdf PDF
W912QR21R0008Plans-0002.pdf PDF
W912QR21R0008Specs-0002.pdf PDF
W912QR21R0008_Specs_CT-0001.pdf PDF
W912QR21R0008_Specs_CT-0000.pdf PDF
W912QR21R0008_Specs_PhaseB_Vol2-0000.pdf PDF
W912QR21R0008_Plans_PhaseB_Vol36-0000.pdf PDF
W912QR21R0008_Plans_PhaseA_Vol10-0000.pdf PDF
W912QR21R0008_Plans_PhaseB_Vol32-0000.pdf PDF
W912QR21R0008_Plans_PhaseB_Vol70-0000.pdf PDF
W912QR21R0008_Plans_PhaseB_Vol33-0000.pdf PDF
W912QR21R0008_Plans_PhaseB_Vol31_Part1-0000.pdf PDF
W912QR21R0008_Specs_PhaseB_Vol1_00800004a06-0000.xlsx XLSX spreadsheet
W912QR21R0008_Plans_PhaseA_Vol60-0000.pdf PDF
W912QR21R0008_Plans_PhaseB_Vol31_Part2-0000.pdf PDF
W912QR21R0008_Plans_PhaseB_Vol34-0000.pdf PDF
W912QR21R0008_Plans_PhaseB_Vol60-0000.pdf PDF
W912QR21R0008_Specs_PhaseB_Vol6-0000.pdf PDF
W912QR21R0008_Plans_PhaseB_Vol50-0000.pdf PDF
W912QR21R0008_Specs_PhaseB_Vol5-0000.pdf PDF
W912QR21R0008_Specs_PhaseB_Vol1-0000.pdf PDF
W912QR21R0008_Specs_PhaseB_Vol7-0000.pdf PDF
W912QR21R0008_Plans_PhaseB_Vol30-0000.pdf PDF
Show 40 more

Latest 50 of 63 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Approved by______________________________________ Date___________ Approved by______________________________________ Date___________

CL64eN-BAS ELECTRIC High Temperature Rack Conveyor Dishwashing Machine

Printed in U.S.A. HOBART • 701 S Ridge Avenue, Troy, OH 45373 • 1-888-4HOBART • www.hobartcorp.com F40682 (01/21) Page 1 of 4

CLeN SERIES – CL64eN-BAS ELECTRIC

COM

M

ERCIAL

DISHW

ASHERS

Project ____________________________________________________________________

AIA # ________________________________ SIS # ________________________________

Item # _______________________________ Quantity ________ C.S.I. Section 114000

SPECIFIER STATEMENT

Specified dishwasher will be Hobart CL64eN Base electric tank heat model with Opti-Rinse™.

Includes 342 racks per hour capacity, dirty water indicator, configurable “intelligent” de-lime noti-fication, top mounted computer con trols, and NSF approved pot and pan cycle mode. The wash tank utilizes durable precision pressure sen-sor monitors in lieu of conventional mechani cal floats. The 19.5" standard chamber height will accommodate up to (6) standard sheet pans at a time on an open-end sheet pan rack.

STANDARD FEATURES

+ 342 racks per hour + Opti-Rinse™ system + Rapid return conveyor drive mechanism + Large double door opening for ease of cleaning + Doors are insulated & hinged with door interlock switches + 19.5" chamber height opening (accepts sheet pans) + Top mounted micro-processor control module + Energy saver mode (programmable auto-shut down) + Dirty water indicator + Manager activated low temperature alert + NSF rated configurable pot and pan dwell mode + Configurable “intelligent” delime notification + Service diagnostics + Self-aligning wash manifolds + Stainless steel anti-clogging wash arms + Removable pump intake screen + Stainless steel self-draining pump and impeller + Single, sloping scrap screen and deep scrap basket + Stainless panels enclose perimeter and bottom + Door actuated drain closure + Convertible hot water or low temp final rinse + Vent fan control + Booster heater control + ENERGY STAR® Certified

OPTIONS & ACCESSORIES (Available at extra cost) ❑ Standard, short, and extended stainless steel vent hoods ❑ Internal stainless steel pressure-less 30 kW booster heater field convertible to 15 kW (booster includes PRV) ❑ Direct drive unloader – adds 38" length. Reference spec

F39520 for more details ❑ Side loader – SL23 adds 23" length, SL30 adds 30" length.

Reference specs F40926 and F40927 for more details ❑ Blower-dryer – adds 331⁄4" to length. Reference spec F40252 for more details (ships separate from dishmachine, contact Hobart Service for installation)

❑ Drain water tempering kit (field installed) ❑ Flanged feet kit (requires two kits) ❑ Higher than standard chamber (24" opening) ❑ Table limit switch with 10' wire ❑ Correctional package (contact Hobart for details) ❑ Pressure regulator valve (PRV), for use with external booster ❑ Water shock absorber kit ❑ Factory-mounted circuit breakers (contact Hobart for details) ❑ Common electrical connection (see page 4)

Hobart CL64EN‐BAS+BUILDUP Item #K2490 W912QR21R0008_Specs_PhaseB_Vol3_Part2-0008

Page 2 of 4 CL64eN-BAS ELECTRIC

High Temperature Rack Conveyor

Dishwashing Machine

CAD and/or Revit Files Available

Top View Left to Right Top View Right to Left

Front View Left to Right Front View Right to Left

Side View

MODEL:

CL64eN BASE

L-R OPERATION

D-974805

REV B

MODEL:

CL64eN BASE

R-L OPERATION

D-974804

REV B

WIDTH OF

TRACKS

WIDTH OF

MACHINE 20" 27"

11"

27"

AVG INSIDE

TABLE WIDTH

14 1/2"

CL

MACHINE 2 HOLES FOR BOLTING

TABLE TO TANK

FRONT OF

MACHINE

CL

3/8"

3/8"

3"

1 1/4"

8" AVG

22"

INSIDE TANK

3"

P3

L-R OPER

68 1/2"

63 1/2"10"

TYP

7 5/8"

5" V1

P2 E1 E2

V1

P2 E2 E1

R-L OPER

68 1/2"

7 5/8"

63 1/2"10"

TYP

31 1/16"

7 3/8"

15 1/8"

13"

9 3/8" 5" RECOMMENDED

MIN. DISTANCE

FROM WALL

22"

BOTH ENDS

WALL

35 3/8" 43 5/16"

60 11/32"

23"

OPEN DOOR

CLEARANCE

20" SERVICE

CLEARANCE

(BOTH SIDES)

20 3/4" 28 3/4"

59 7/8"

20" SERVICE

CLEARANCE

(BOTH SIDES)

23"

OPEN DOOR

CLEARANCE

P3 P360 1/4"60 1/4"

P1 P1

34"

View Showing Hole Locations in Turned Down Portion of Table

Tabling Connection: 64" inside tank (at table connection)

Suggested Track and Table Layout

Hobart CL64EN‐BAS+BUILDUP Item #K2490 http://hobart.kclcad.com/mobile

High Temperature Rack Conveyor

Dishwashing Machine

CL64eN-BAS ELECTRIC Page 3 of 4

SPECIFICATIONS

Capacities Racks Per Hour (NSF rated) Wash Tank (U.S. gallons) Rinse Tank (U.S. gallons) Conveyor Speed (feet per minute) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.5 Motor Horsepower Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/6 Wash Rinse Water Consumption U.S. Gallons per Hour (maximum use at 20 PSI) U.S. Gallons per Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.39 Peak Drain Flow (U.S. gallons per minute) Heating Tank Heat, Electric (kW) Optional Electric Booster (built-in) (kW for 40°F rise) Optional Electric Booster (built-in) (kW for 70°F rise) Venting Load End (minimum CFM) Unload End (minimum CFM) Shipping Weight (approximate) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .840 lbs.

Crated Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .74"L x 38"W x 78"H

LEGEND

Electrical Connections

E1 Motors, controls, and electric tank heat 1-1/4" or 2" conduit, 63-3/4" AFF.

E2 Internal electric booster 1-1/4" or 2" conduit, 63-3/4" AFF.

NOTE: Common electrical connection (single point) available, see page 4 for details.

Plumbing Connections

P1

Drain. May be drained to either side of valve, plug opposite side 2" FPT.

Recommend a floor drain minimum of 12'' from machine for access and maintenance. 7-3/8" AFF.

P2 Hot water. 1/2" FPT connection.

1/2", 11-3/16" AFF. See plumbing notes for required temperatures.

P3 Optional cold water connection for drain water tempering 1/2" FPT, cold water temperature 80°F, maximum 7-3/8" AFF.

Vent Connections

V1 Optional vent hoods, 4" x 16" vent stack with damper.

E1 Electrical Connection (3 PH only) Motors, Controls and Electric Tank Heat

Voltage Rated Amps

Minimum Supply Circuit

Ampacity

Maximum Protective

Device 208/60/3 90.6 125 125 240/60/3 86.6 125 125 480/60/3 44.9 60 60 600/60/3 32.2 45 45

NOTE: Electric tank heat can be split from motors & c ontrols, see page 4 for details.

Dishmachine not provided with internal GFCI protection.

CL64eN-BAS Electric Heat Dissipation

Booster

BTU/HR.

Latent Sensible Without Booster 24,800 10,600

15kW Booster 38,400 16,400 30kW Booster 51,900 22,200

E2 Booster Heat 30 kW (Standard) Minimum 110°F Incoming Water

Voltage Rated Amps

Minimum Supply Circuit

Ampacity

Maximum Protective

Device 208/60/3 83.9 90 90 240/60/3 80.2 90 90 480/60/3 40.1 50 50 600/60/3 26.9 40 40

E2 Booster Heat 15 kW (Field Convertible) Minimum 140°F Incoming Water

Voltage Rated Amps

Minimum Supply Circuit

Ampacity

Maximum Protective

Device 208/60/3 45.0 60 60 240/60/3 40.1 50 50 480/60/3 20.0 25 25 600/60/3 13.5 20 20

WARNING: Plumbing and electrical connections should be made by qualified personnel who will observe all the applicable plumbing, sanitary, safety codes and National Electrical Code.

Plumbing Notes: Minimum incoming water temperatures:

110°F for 30kW internal booster, 140°F for 15kW field converted internal booster, 180°F without internal booster.

Building flowing water pressure to dish machine is 20 PSI, (+/- 5 PSI). For non-booster machines, a PRV with internal expansion bypass is required. When ordered as an accessory, 1⁄2" brass regulator must be installed before the booster.

Water temperature to the regulator must not exceed 140°F.

Recommended water hardness to be 3 grains or less for best results.

NOTE: Additional CLeN Voltages and Amperages are available, see document F40972.

High Temperature Rack Conveyor

Dishwashing Machine

As continued product improvement is a policy of Hobart, specifications are subject to change without notice.

F40682 (01/21) Page 4 of 4 HOBART • 701 S Ridge Avenue, Troy, OH 45373 • 1-888-4HOBART • www.hobartcorp.com Printed in U.S.A.

COMMON ELECTRICAL CONNECTION (SINGLE POINT) – CONTACT FACTORY FOR ADDITIONAL INFORMATION Common Electrical Connection

(Includes Motors & Controls, Electric Wash Tank Heat, Electric Rinse Tank Heat & Electric Booster Heater)

Voltage

MACHINE AND 15kW BOOSTER MACHINE AND 30kW BOOSTER

Rated Amps

Minimum Supply Circuit

Ampacity

Maximum Protective

Device Rated Amps

Minimum Supply Circuit

Ampacity

Maximum Protective

Device 208/60/3 136 150 150 175 200 200 240/60/3 127 150 150 167 200 200 480/60/3 65 80 80 85 100 100 600/60/3 45.7 65 65 59.1 85 85

VENT HOOD OPTIONS (Adjustable, vent stack can be adjusted 1" to either side)

Standard Short Extended

4 3/4"

OUTSIDE

11 1/4"

OUTSIDE

REF

10" 10"

4 3/4"

OUTSIDE

5 3/4"

OUTSIDE

REF

10"

4 3/4"

OUTSIDE

20 1/2"

OUTSIDE

REF

Separate Service Connection for Motors & Controls

Voltage Rated Amps

Minimum Supply Circuit

Ampacity

Maximum Protective

Device 208/60/3 15.6 20 20 240/60/3 15.1 20 20 480/60/3 9.1 20 20 600/60/3 8.2 15 15

Separate Service Connection for Wash Tank

Voltage Rated Amps

Minimum Supply Circuit

Ampacity

Maximum Protective

Device 208/60/3 45.0 60 60 240/60/3 43.0 60 60 480/60/3 22.0 30 30 600/60/3 14.4 20 20

Separate Service Connection for 10 kW Rinse Tank

Voltage Rated Amps

Minimum Supply Circuit

Ampacity

Maximum Protective

Device 208/60/3 30.0 40 40 240/60/3 28.6 40 40 480/60/3 14.3 20 20 600/60/3 9.6 15 15

FIELD CONVERTIBLE SERVICE CONNECTIONS

At time of installation, service connections for motors, controls, and electric tank heat can be split as necessary for installation.

NOTE: Additional CLeN Voltages and Amperages are available, see document F40972.

File details come from the government source that posted it. Updated .