W912QR21R0008_Plans-0003.pdf
PDF 42 MB Posted
- Solicitation number
- W912QR21R0008
About this file
This document provides details on an upcoming federal contract opportunity for the construction of a new medical center campus to replace aging facilities at the Robley Rex VA Medical Center in Louisville, Kentucky. The Department of the Army Corps of Engineers Louisville District intends to issue a Request for Proposal for a single firm-fixed-price construction contract valued at approximately $705 million. The contract scope involves designing and building a new 104-bed hospital, parking structures for 2,600 cars, campus infrastructure, a new central utility plant and laundry facility. The solicitation is anticipated for release on December 3, 2020 and will utilize a best value tradeoff source selection process evaluating technical factors and price. The construction magnitude is over $500 million and the contract duration is 1,554 calendar days from notice to proceed.
View the file
Other files
Show 40 more
Latest 50 of 63 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
B1 B2 B3
B4 B5 B6
C2 D1
G1
J1
J2
K2
L1
P1
M1
D2
C1
E
F
B1E
B4F
B4E
N2
N1
L2 K1
BUILDING AREA LEGEND
A NOT USED
B VA MEDICAL CENTER (VAMC)
C DOCK/LAUNDRY FACILITY
D CENTRAL UTILITY PLANT (CUP)
E NORTH PARKING
F SOUTH PARKING
G MAINTENANCE BUILDING
H NOT USED
I NOT USED
J GUARD HOUSES
K1 WATER TOWER
K2 WATER TANK
L ELECTRICAL SERVICE BUILDINGS
M BUS SHELTER
N COVERED WALKWAYS
P PUMP HOUSE
SHEET NUMBER LEGEND (NON-PLAN)
S F 3 1 01 B
DISCIPLINE DESIGNATOR
G GENERAL
H HAZARDOUS MATERIALS
V SURVEYING/MAPPING
B GEOTECHNICAL
C CIVIL
L LANDSCAPE
S STRUCTURAL
A ARCHITECTURAL
I INTERIORS
Q EQUIPMENT
F FIRE PROTECTION
P PLUMBING
D PROCESS
M MECHANICAL
E ELECTRICAL
T TELECOMM
LEVEL 2 DESIGNATOR - STRU
STRUCTURAL:
F STRUCTURAL BUILDING DRAWINGS
S SITE DRAWINGS
J SIDEPLATE DRAWINGS
SHEET TYPE DESIGNATOR
0 GENERAL
1 PLANS
2 ELEVATIONS
3 LARGE-SCALE SECTIONS
4 LARGE-SCALE VIEWS
5 SECTIONS & DETAILS
6 SCHEDULES & DIAGRAMS
7 USER DEFINIED
8 USER DEFINIED
9 3D REPRESENTATIONS
SHEET TYPE SUB SERIES
1-9 INDICATES SUB SERIES TYPE
AS REQUIRED
SHEET SEQUENCE
01-99
KEY PLAN AREA
A NOT USED
B VA MEDICAL CENTER (VAMC)
C DOCK/LAUNDRY FACILITY
D CENTRAL UTILITY PLANT (CUP)
E NORTH PARKING
F SOUTH PARKING
G MAINTENANCE BUILDING
H SMOKING SHELTERS
I NOT USED
J GUARD HOUSES
K1 WATER TOWER
K2 WATER TANK
L ELECTRICAL SERVICE BUILDINGS
M BUS SHELTER
N COVERED WALKWAYS
P PUMP HOUSE
SHEET NUMBER LEGEND
S F 1 01 B1
DISCIPLINE DESIGNATOR
G GENERAL
H HAZARDOUS MATERIALS
V SURVEYING/MAPPING
B GEOTECHNICAL
C CIVIL
L LANDSCAPE
S STRUCTURAL
A ARCHITECTURAL
I INTERIORS
Q EQUIPMENT
F FIRE PROTECTION
P PLUMBING
D PROCESS
M MECHANICAL
E ELECTRICAL
T TELECOMM
LEVEL 2 DESIGNATOR - STRU SHEET TYPE DESIGNATOR
0 GENERAL
1 PLANS
2 ELEVATIONS
3 LARGE-SCALE SECTIONS
4 LARGE-SCALE VIEWS
5 SECTIONS & DETAILS
6 SCHEDULES & DIAGRAMS
7 USER DEFINIED
8 USER DEFINIED
9 3D REPRESENTATIONS
BUILDING LEVEL
XX VARIES AT NON-PLANS
0B UNDERGROUND
00 GROUND LEVEL
01 LEVEL 1
01i LEVEL 1i
02 LEVEL 2
03 LEVEL 3
04 LEVEL 4
04i LEVEL 4i
05 LEVEL 5
06 LEVEL 6
07 LEVEL 7
08 LEVEL 8
09 LEVEL 9
10 LEVEL 10
KEY PLAN AREA / ZONE
KEY PLAN AREA AS DESIGNATED BY:
ON THIS PLAN
LETTER DENOTES KEY PLAN AREA
NUMBER DENOTES KEY PLAN ZONE
USE 01, 02 ETC FOR DRAWINGS
IN A SEQUENCE FOR NON-PLANS
B1STRUCTURAL:
F STRUCTURAL BUILDING DRAWINGS
S SITE DRAWINGS
J SIDEPLATE DRAWINGS
P lo t D at e th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
CONSTRUCTION DOCUMENTS -
URS | SMITHGROUP JOINT VENTURE
500 WEST JEFFERSON ST.
Suite 1600
LOUISVILLE, KY 40202
T 313.983.3600
F 313.983.3636 www.urscorp.com | www.smithgroupjjr.com
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Drawing Number
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Office of Facilities
Management
B
A
C
D
E
F
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321 o n e s ix te e n th in c h o n e fo o t o n e th ir ty s e c o n d th in c h o n e fo o t
PROJECT # 14576907/22200.000
OFFICE OF CONSTRUCTION & FACILITIES MANAGEMENT - CENTRAL REGION
3001 GREEN BAY ROAD
BUILDING 48
NORTH CHICAGO, IL 60064
T 224.610.3492
U.S. DEPARTMENT OF VETERANS AFFAIRS
SHEET INDEX ID:
USACE LOUISVILLE DISTRICT
600 DR. MARTIN LUTHER KING PLACE
LOUISVILLE, KY 40202
PHONE: 502-315-6766
FAX: 502-315-6195
CONTRACTING DIVISION
OrientationSeal
CERTIFIED FINAL
Mark
1/ 7/
:4
7:
P M
11JAN2021
SF0000
BUILDING AREA DESIGNATION PLAN -
STRUCTURAL
EJM JDB
Louisville, Kentucky
REPLACEMENT VA MEDICAL CENTER
VA Project No. 603-320 USACE P2 No. 453413
302.07.0.S1-SF0000-STRUCTURAL
20NOV2020
SCALE: 1" = 60'-0"
BUILDING AREA DESIGNATION PLAN
PHB CERTIFIED FINAL 20NOV2020
AMENDMENT 0003 1 11JAN2021
W
2Q R
R
-0
BUILDING AREA LEGEND
A NOT USED
B VA MEDICAL CENTER (VAMC)
C DOCK/LAUNDRY FACILITY
D CENTRAL UTILITY PLANT (CUP)
E NORTH PARKING
F SOUTH PARKING
G MAINTENANCE BUILDING
H NOT USED
I NOT USED
J GUARD HOUSES
K1 WATER TOWER
K2 WATER TANK
L ELECTRICAL SERVICE BUILDINGS
M BUS SHELTER
N COVERED WALKWAYS
P1 PUMP HOUSE
SHEET NUMBER LEGEND
P L 1 01 B1
DISCIPLINE DESIGNATOR
G GENERAL
H HAZARDOUS MATERIALS
V SURVEYING/MAPPING
B GEOTECHNICAL
C CIVIL
L LANDSCAPE
S STRUCTURAL
A ARCHITECTURAL
I INTERIORS
Q EQUIPMENT
F FIRE PROTECTION
P PLUMBING
D PROCESS
M MECHANICAL
E ELECTRICAL
T TELECOMM
LEVEL 2 DESIGNATOR - MECH
PLUMBING:
L ALL PLUMBING
SHEET TYPE DESIGNATOR
0 GENERAL
1 PLANS
2 MED GAS PLANS
3 SECTIONS
4 ENLARGED PLANS
5 DETAILS
6 SCHEDULES
7 DIAGRAMS
8 SEQUENCE OF OPERATIONS/CONTROLS
9 3D REPRESENTATIONS
BUILDING LEVEL
0B UNDERGROUND
00 GROUND LEVEL
01 LEVEL 1
01i LEVEL 1i
02 LEVEL 2
03 LEVEL 3
04 LEVEL 4
04i LEVEL 4i
05 LEVEL 5
06 LEVEL 6
07 LEVEL 7
08 LEVEL 8
09 LEVEL 9
10 LEVEL 10
KEY PLAN AREA / ZONE
KEY PLAN AREA AS DESIGNATED BY:
ON THIS PLAN
LETTER DENOTES KEY PLAN AREA
NUMBER DENOTES KEY PLAN ZONE
USE 01, 02 ETC FOR DRAWINGS
IN A SEQUENCE FOR NON-PLANS
B1
SHEET NUMBER LEGEND (NON-PLAN)
P L 3 01 B
DISCIPLINE DESIGNATOR
G GENERAL
H HAZARDOUS MATERIALS
V SURVEYING/MAPPING
B GEOTECHNICAL
C CIVIL
L LANDSCAPE
S STRUCTURAL
A ARCHITECTURAL
I INTERIORS
Q EQUIPMENT
F FIRE PROTECTION
P PLUMBING
D PROCESS
M MECHANICAL
E ELECTRICAL
T TELECOMM
LEVEL 2 DESIGNATOR - ARCH
PLUMBING:
L ALL PLUMBING
SHEET TYPE DESIGNATOR
0 GENERAL
1 NOT USED
2 NOT USED
3 SECTIONS
4 ENLARGED PLANS
5 DETAILS
6 SCHEDULES
7 DIAGRAMS
8 SEQUENCE OF OPERATIONS/CONTROLS
9 3D REPRESENTATIONS
SHEET SEQUENCE
01-99
KEY PLAN AREA
A NOT USED
B VA MEDICAL CENTER (VAMC)
C DOCK/LAUNDRY FACILITY
D CENTRAL UTILITY PLANT (CUP)
E NORTH PARKING
F SOUTH PARKING
G MAINTENANCE BUILDING
H SMOKING SHELTERS
I NOT USED
J GUARD HOUSES
K1 WATER TOWER
K2 WATER TANK
L ELECTRICAL SERVICE BUILDINGS
M BUS SHELTER
N COVERED WALKWAYS
P PUMP HOUSE
B1 B2 B3
B4 B5 B6
C2 D1
G1
J1
J2
K2
L1
L2
M1
D2
C1
E1 E2
E3 E4
F1 F2
F3 F4
B1E
B4E
B4F
N1
N2
P1
K1
P lo t D at e th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
CONSTRUCTION DOCUMENTS -
URS | SMITHGROUP JOINT VENTURE
500 WEST JEFFERSON ST.
Suite 1600
LOUISVILLE, KY 40202
T 313.983.3600
F 313.983.3636 www.urscorp.com | www.smithgroupjjr.com
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Drawing Number
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Office of Facilities
Management
B
A
C
D
E
F
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321 o n e s ix te e n th in c h o n e fo o t o n e th ir ty s e c o n d th in c h o n e fo o t
PROJECT # 14576907/22200.000
OFFICE OF CONSTRUCTION & FACILITIES MANAGEMENT - CENTRAL REGION
3001 GREEN BAY ROAD
BUILDING 48
NORTH CHICAGO, IL 60064
T 224.610.3492
U.S. DEPARTMENT OF VETERANS AFFAIRS
SHEET INDEX ID:
USACE LOUISVILLE DISTRICT
600 DR. MARTIN LUTHER KING PLACE
LOUISVILLE, KY 40202
PHONE: 502-315-6766
FAX: 502-315-6195
CONTRACTING DIVISION
OrientationSeal
CERTIFIED FINAL
Mark
1/ 8/
:5
8:
A M
11JAN2021
PL0000
PLUMBING BUILDING AREA
DESIGNATION PLAN
HCH KFM
Louisville, Kentucky
REPLACEMENT VA MEDICAL CENTER
VA Project No. 603-320 USACE P2 No. 453413
2.12.1.P0-PL0000-PLUMBING
20NOV2020
PHB CERTIFIED FINAL 20NOV2020
AMENDMENT 0003 1 11JAN2021
W
2Q R
R
-0
B VA MEDICAL CENTER (VAMC)
C DOCK/LAUNDRY FACILITY
D CENTRAL UTILITY PLANT (CUP)
E NORTH PARKING
F SOUTH PARKING
G MAINTENANCE BUILDING
H NOT USED
I NOT USED
J GUARD HOUSES
K1 WATER TOWER
K2 WATER TANK
L ELECTRICAL SERVICE BUILDINGS
M BUS SHELTER
N COVERED WALKWAYS
P PUMP HOUSE
SHEET NUMBER LEGEND
M H 1 01 B1
DISCIPLINE DESIGNATOR
G GENERAL
H HAZARDOUS MATERIALS
V SURVEYING/MAPPING
B GEOTECHNICAL
C CIVIL
L LANDSCAPE
S STRUCTURAL
A ARCHITECTURAL
I INTERIORS
Q EQUIPMENT
F FIRE PROTECTION
P PLUMBING
D PROCESS
M MECHANICAL
E ELECTRICAL
T TELECOMM
LEVEL 2 DESIGNATOR - MECH
MECHANICAL:
H ALL MECHANICAL
SHEET TYPE DESIGNATOR
0 GENERAL
1 DUCTWORK PLANS
2 PIPING PLANS
3 SECTIONS
4 ENLARGED PLANS
5 DETAILS
6 SCHEDULES
7 DIAGRAMS
8 SEQUENCE OF OPERATIONS/CONTROLS
9 3D REPRESENTATIONS
BUILDING LEVEL
XX VARIES AT NON-PLANS
00 GROUND LEVEL
01 LEVEL 1
1i LEVEL 1i
02 LEVEL 2
03 LEVEL 3
04 LEVEL 4
4i LEVEL 4i
05 LEVEL 5
06 LEVEL 6
07 LEVEL 7
08 LEVEL 8
09 LEVEL 9
10 LEVEL 10
KEY PLAN AREA / ZONE
KEY PLAN AREA AS DESIGNATED BY:
ON THIS PLAN
LETTER DENOTES KEY PLAN AREA
NUMBER DENOTES KEY PLAN ZONE
USE 01, 02 ETC FOR DRAWINGS
IN A SEQUENCE FOR NON-PLANS
B1
SHEET NUMBER LEGEND (NON-PLAN)
M H 3 1 01 B
DISCIPLINE DESIGNATOR
G GENERAL
H HAZARDOUS MATERIALS
V SURVEYING/MAPPING
B GEOTECHNICAL
C CIVIL
L LANDSCAPE
S STRUCTURAL
A ARCHITECTURAL
I INTERIORS
Q EQUIPMENT
F FIRE PROTECTION
P PLUMBING
D PROCESS
M MECHANICAL
E ELECTRICAL
T TELECOMM
LEVEL 2 DESIGNATOR - ARCH
MECHANICAL:
H ALL MECHANICAL
SHEET TYPE DESIGNATOR
0 GENERAL
1 NOT USED
2 NOT USED
3 SECTIONS
4 ENLARGED PLANS
5 DETAILS
6 SCHEDULES
7 DIAGRAMS
8 SEQUENCE OF OPERATIONS/CONTROLS
9 3D REPRESENTATIONS
SHEET TYPE SUB SERIES
1-9 INDICATES SUB SERIES TYPE
AS REQUIRED
SHEET SEQUENCE
01-99
KEY PLAN AREA
A NOT USED
B VA MEDICAL CENTER (VAMC)
C LAUNDRY FACILITY
D CENTRAL UTILITY PLANT (CUP)
E NORTH PARKING
F SOUTH PARKING
G MAINTENANCE BUILDING
H SMOKING SHELTERS
I NOT USED
J GUARD HOUSES
K WATER TOWER
L ELECTRICAL SERVICE BUILDINGS
M BUS SHELTER
P PUMP HOUSE
B1 B2 B3
B4 B5 B6
C2 D1
G1
J1
J2
K1
L1
L2
M1
D2
C1
E1 E2
E3 E4
F1 F2
F3 F4
B1E
B4F
B4E
N2
N1
P1
K2
P lo t D at e th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
CONSTRUCTION DOCUMENTS -
URS | SMITHGROUP JOINT VENTURE
500 WEST JEFFERSON ST.
Suite 1600
LOUISVILLE, KY 40202
T 313.983.3600
F 313.983.3636 www.urscorp.com | www.smithgroupjjr.com
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Drawing Number
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Office of Facilities
Management
B
A
C
D
E
F
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
TRUE NORTH
PROJECT NORTH
97 8654321 o n e s ix te e n th in c h o n e fo o t o n e th ir ty s e c o n d th in c h o n e fo o t
PROJECT # 14576907/22200.000
OFFICE OF CONSTRUCTION & FACILITIES MANAGEMENT - CENTRAL REGION
3001 GREEN BAY ROAD
BUILDING 48
NORTH CHICAGO, IL 60064
T 224.610.3492
U.S. DEPARTMENT OF VETERANS AFFAIRS
SHEET INDEX ID:
USACE LOUISVILLE DISTRICT
600 DR. MARTIN LUTHER KING PLACE
LOUISVILLE, KY 40202
PHONE: 502-315-6766
FAX: 502-315-6195
CONTRACTING DIVISION
OrientationSeal
CERTIFIED FINAL
Mark
1/
/2
:1 7:
A
M
11JAN2021
MH0000
BUILDING AREA DESIGNATION PLAN -
MECHANICAL
CAO CRW
Louisville, Kentucky
REPLACEMENT VA MEDICAL CENTER
VA Project No. 603-320 USACE P2 No. 45313
0.14.1.M0-MH0000-Phase B-MECHANICAL
20NOV2020
SCALE: NOT TO SCALE
BUILDING AREA DESIGNATION PLAN
PHB CERTIFIED FINAL 20NOV2020
AMENDMENT 0003 1 11JAN2021
W
2Q R
R
-0
B VA MEDICAL CENTER (VAMC)
C LAUNDRY FACILITY
D CENTRAL UTILITY PLANT (CUP)
E NORTH PARKING STRUCTURE
F SOUTH PARKING STRUCTURE
G MAINTENANCE BUILDING
H NOT USED
I NOT USED
J GUARD HOUSES
K WATER TOWER
L ELECTRICAL SERVICE BUILDINGS
M BUS SHELTER
N COVERED WALKWAYS
P PUMP HOUSE
SHEET NUMBER LEGEND
E E 1 01 B1 A
DISCIPLINE DESIGNATOR
G GENERAL
H HAZARDOUS MATERIALS
V SURVEYING/MAPPING
B GEOTECHNICAL
C CIVIL
L LANDSCAPE
S STRUCTURAL
A ARCHITECTURAL
I INTERIORS
Q EQUIPMENT
F FIRE PROTECTION
P PLUMBING
D PROCESS
M MECHANICAL
E ELECTRICAL
T TELECOMM
LEVEL 2 DESIGNATOR - ELEC
ELECTRICAL:
E ALL ELECTRICAL
SHEET TYPE DESIGNATOR
0 GENERAL
1 LIGHTING PLANS
2 POWER PLANS
3 GROUNDING & LIGHTNING PROTECTION PLANS
4 ENLARGED PLANS AND ELEVATIONS
5 DETAILS
6 SCHEDULES
7 ONE-LINE DIAGRAMS
8 SEQUENCE OF OPERATIONS/CONTROLS
9 3D REPRESENTATIONS
BUILDING LEVEL
XX VARIES AT NON-PLANS
0L LOWER GROUND LEVEL
00 GROUND LEVEL
01 LEVEL 1
1i LEVEL 1 INTERSTITIAL
02 LEVEL 2
03 LEVEL 3
04 LEVEL 4
4i LEVEL 4 INTERSTITIAL
05 LEVEL 5
06 LEVEL 6
07 LEVEL 7
08 LEVEL 8
09 LEVEL 9
10 LEVEL 10
KEY PLAN AREA / ZONE
KEY PLAN AREA AS DESIGNATED BY:
ON THIS PLAN
LETTER DENOTES KEY PLAN AREA
NUMBER DENOTES KEY PLAN ZONE
USE 01, 02 ETC FOR DRAWINGS
IN A SEQUENCE FOR NON-PLANS THAT APPLY
TO MULTIPLE BUILDINGS
DRAWING SEQUENCE
USE A, B ETC FOR DRAWINGS
IN A SEQUENCE
B1
SHEET NUMBER LEGEND (NON-PLAN)
E E 3 01 B
DISCIPLINE DESIGNATOR
G GENERAL
H HAZARDOUS MATERIALS
V SURVEYING/MAPPING
B GEOTECHNICAL
C CIVIL
L LANDSCAPE
S STRUCTURAL
A ARCHITECTURAL
I INTERIORS
Q EQUIPMENT
F FIRE PROTECTION
P PLUMBING
D PROCESS
M MECHANICAL
E ELECTRICAL
T TELECOMM
LEVEL 2 DESIGNATOR - ELEC
ELECTRICAL:
E ALL ELECTRICAL
SHEET TYPE DESIGNATOR
0 GENERAL
1 NOT USED
2 NOT USED
3 SECTIONS
4 ENLARGED PLANS
5 DETAILS
6 SCHEDULES
7 DIAGRAMS
8 SEQUENCE OF OPERATIONS/CONTROLS
9 3D REPRESENTATIONS
SHEET SEQUENCE
01-99
KEY PLAN AREA
A NOT USED
B VA MEDICAL CENTER (VAMC)
C LAUNDRY FACILITY
D CENTRAL UTILITY PLAN (CUP)
E NORTH PARKING
F SOUTH PARKING
G MAINTENANCE BUILDING
H SMOKING SHELTERS
I NOT USED
J GUARD HOUSES
K WATER TOWER
L ELECTRICAL SERVICE BUILDINGS
M BUS SHELTER
B1 B2 B3
B4 B5 B6
C2 D1
G1
J1
J2
K2
L1
L2
M1
D2
C1
E1 E2
E3 E4
F1 F2
F3 F4
B1E
B4F
B4E
N2
P
N1
K1
P lo t D at e th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
CONSTRUCTION DOCUMENTS - FULLY SPRINKLERED
URS | SMITHGROUP JOINT VENTURE
500 WEST JEFFERSON ST.
Suite 1600
LOUISVILLE, KY 40202
T 313.983.3600
F 313.983.3636 www.urscorp.com | www.smithgroupjjr.com
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Drawing Number
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Office of Facilities
Management
B
A
C
D
E
F
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
TRUE NORTH
PROJECT NORTH
97 8654321 o n e s ix te e n th in c h o n e fo o t o n e th ir ty s e c o n d th in c h o n e fo o t
PROJECT # 14576907/22200.000
OFFICE OF CONSTRUCTION & FACILITIES MANAGEMENT - CENTRAL REGION
3001 GREEN BAY ROAD
BUILDING 48
NORTH CHICAGO, IL 60064
T 224.610.3492
U.S. DEPARTMENT OF VETERANS AFFAIRS
SHEET INDEX ID:
USACE LOUISVILLE DISTRICT
600 DR. MARTIN LUTHER KING PLACE
LOUISVILLE, KY 40202
PHONE: 502-315-6766
FAX: 502-315-6195
CONTRACTING DIVISION
OrientationSeal
CERTIFIED FINAL
Mark
1/
/2
3:
:2
P
M
11JAN2021
EE000
ELECTRICAL BUILDING AREA
DESIGNATION PLAN
BJW TES
Louisville, Kentucky
REPLACEMENT VA MEDICAL CENTER
VA Project No. 603-320 USACE P2 No. 453413
0.15.1.E0-EE000-Phase B-ELECTRICAL
SCALE: 1" = 60'-0"
ELECTRICAL BUILDING AREA
DESIGNATION PLAN PROJECT NORTH
PHB CERTIFIED FINAL 20NOV2020
AMENDMENT 0003 1 11JAN2021
W
2Q R
R
-0
B1 B2 B3
B4 B5 B6
C2 D1
G1
J1
J2
K1
L1
L2
M1
D2
C1
B1E
B4E
B4F
N1
N2
P1
E
F
SHEET NUMBER LEGEND (NON-PLAN)
A E 3 1 01 B
DISCIPLINE DESIGNATOR
G GENERAL
H HAZARDOUS MATERIALS
V SURVEYING/MAPPING
B GEOTECHNICAL
C CIVIL
L LANDSCAPE
S STRUCTURAL
A ARCHITECTURAL
I INTERIORS
Q EQUIPMENT
F FIRE PROTECTION
P PLUMBING
D PROCESS
M MECHANICAL
E ELECTRICAL
T TELECOMM
LEVEL 2 DESIGNATOR - ARCH
GENERAL:
I INFORMATION
C CONTRACTURAL
R RESOURCE
SHEET TYPE DESIGNATOR
0 GENERAL
1 NOT USED
2 ELEVATIONS
3 SECTIONS
4 LARGE-SCALE VIEWS
5 DETAILS
6 SCHEDULES & DIAGRAMS
7 USER DEFINED
8 USER DEFINED
9 3D REPRESENTATIONS
SHEET TYPE SUB SERIES
1-9 INDICATES SUB SERIES TYPE
AS REQUIRED
SHEET SEQUENCE
01-99
ARCHITECTURAL:
D DEMO
S SITE
E ELEMENTS
I INTERIORS
F FINISHES
G GRAPHICS
INTERIORS:
D DEMO
N DESIGN
F FURNISHINGS
G GRAPHICS
EQUIPMENT:
A ATHLETIC
B BANK
C CANTEEN
D DOCK
E EDUCATIONAL
F FOOD SERVICE
H HOSPITAL
L LABORATORY
M MAINTENANCE
P PARKING LOT
R CANTEEN RETAIL
S SITE
T TEXTILE CARE
(LAUNDRY)
V VIDEO
KEY PLAN AREA
A NOT USED
B VA MEDICAL CENTER (VAMC)
C LAUNDRY FACILITY
D CENTRAL UTILITY PLAN (CUP)
E NORTH PARKING STRUCTURE
F SOUTH PARKING STRUCTURE
G MAINTENANCE BUILDING
H SMOKING SHELTERS
I NOT USED
J GUARD HOUSES
K WATER TOWER
L ELECTRICAL SERVICE BUILDINGS
M BUS SHELTER
SHEET NUMBER LEGEND
A E 1 01 B1
DISCIPLINE DESIGNATOR
G GENERAL
H HAZARDOUS MATERIALS
V SURVEYING/MAPPING
B GEOTECHNICAL
C CIVIL
L LANDSCAPE
S STRUCTURAL
A ARCHITECTURAL
I INTERIORS
Q EQUIPMENT
F FIRE PROTECTION
P PLUMBING
D PROCESS
M MECHANICAL
E ELECTRICAL
T TELECOMM
LEVEL 2 DESIGNATOR - ARCH
GENERAL:
I INFORMATION
C CONTRACTURAL
R RESOURCE
SHEET TYPE DESIGNATOR
0 GENERAL
1 PLANS
1C REFLECTED CEILING PLANS
2 ELEVATIONS
3 SECTIONS
4 LARGE-SCALE VIEWS
5 DETAILS
6 SCHEDULES & DIAGRAMS
7 USER DEFINED
8 USER DEFINED
9 3D REPRESENTATIONS
BUILDING LEVEL
XX VARIES AT NON-PLANS
00 GROUND LEVEL
01 LEVEL 1
1i LEVEL 1i
02 LEVEL 2
03 LEVEL 3
04 LEVEL 4
4i LEVEL 4i
05 LEVEL 5
06 LEVEL 6
07 LEVEL 7
08 LEVEL 8
09 LEVEL 9
10 LEVEL 10
*OMIT LEADING "0" AT REFLECTED CEILING
PLANS
KEY PLAN AREA / ZONE
KEY PLAN AREA AS DESIGNATED BY:
ON THIS PLAN
LETTER DENOTES KEY PLAN AREA
NUMBER DENOTES KEY PLAN ZONE
USE 01, 02 ETC FOR DRAWINGS
IN A SEQUENCE FOR NON-PLANS
B1
ARCHITECTURAL:
D DEMO
S SITE
E ELEMENTS
I INTERIORS
F FINISHES
G GRAPHICS
INTERIORS:
D DEMO
N DESIGN
F FURNISHINGS
G GRAPHICS
EQUIPMENT:
A ATHLETIC
B BANK
C CANTEEN
D DOCK
E EDUCATIONAL
F FOOD SERVICE
H HOSPITAL
L LABORATORY
M MAINTENANCE
P PARKING LOT
R CANTEEN RETAIL
S SITE
T TEXTILE CARE
(LAUNDRY)
V VIDEO
BUILDING AREA LEGEND
A NOT USED
B VA MEDICAL CENTER (VAMC)
C LAUNDRY FACILITY
D CENTRAL UTILITY PLANT (CUP)
E NORTH PARKING STRUCTURE
F SOUTH PARKING STRUCTURE
G MAINTENANCE BUILDING
H NOT USED
I NOT USED
J GUARD HOUSES
K WATER TOWER
L ELECTRICAL SERVICE BUILDINGS
M BUS SHELTER
N COVERED WALKWAYS
P PUMP HOUSE
P lo t D at e th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
CONSTRUCTION DOCUMENTS -
URS | SMITHGROUP JOINT VENTURE
500 WEST JEFFERSON ST.
Suite 1600
LOUISVILLE, KY 40202
T 313.983.3600
F 313.983.3636 www.urscorp.com | www.smithgroupjjr.com
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Drawing Number
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Office of Facilities
Management
B
A
C
D
E
F
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321 o n e s ix te e n th in c h o n e fo o t o n e th ir ty s e c o n d th in c h o n e fo o t
PROJECT # 14576907/22200.000
OFFICE OF CONSTRUCTION & FACILITIES MANAGEMENT - CENTRAL REGION
3001 GREEN BAY ROAD
BUILDING 48
NORTH CHICAGO, IL 60064
T 224.610.3492
U.S. DEPARTMENT OF VETERANS AFFAIRS
SHEET INDEX ID:
USACE LOUISVILLE DISTRICT
600 DR. MARTIN LUTHER KING PLACE
LOUISVILLE, KY 40202
PHONE: 502-315-6766
FAX: 502-315-6195
CONTRACTING DIVISION
OrientationSeal
CERTIFIED FINAL
Mark
1/
/2
6:
:3
P
M
11JAN2020
A000
BUILDING AREA DESIGNATION PLAN
ARCHITECTURE
HCG L&F
LOUISVILLE, KENTUCKY
REPLACEMENT VA MEDICAL CENTER
VA Project No. 603-320 USACE P2 No. 453413
601.08.1.A0-A000-Phase A-ARCHITECTURAL
20NOV2020
PHA CERTIFIED FINAL 20NOV2020
AMENDMENT 0003 1 11JAN2020
W
2Q R
R
-0
B VA MEDICAL CENTER (VAMC)
C LAUNDRY FACILITY
D CENTRAL UTILITY PLANT (CUP)
E NORTH PARKING STRUCTURE
F SOUTH PARKING STRUCTURE
G MAINTENANCE BUILDING
H NOT USED
I NOT USED
J GUARD HOUSES
K WATER TOWER
L ELECTRICAL SERVICE BUILDINGS
M BUS SHELTER
N COVERED WALKWAYS
P PUMP HOUSE
SHEET NUMBER LEGEND
E E 1 01 B1 A
DISCIPLINE DESIGNATOR
G GENERAL
H HAZARDOUS MATERIALS
V SURVEYING/MAPPING
B GEOTECHNICAL
C CIVIL
L LANDSCAPE
S STRUCTURAL
A ARCHITECTURAL
I INTERIORS
Q EQUIPMENT
F FIRE PROTECTION
P PLUMBING
D PROCESS
M MECHANICAL
E ELECTRICAL
T TELECOMM
LEVEL 2 DESIGNATOR - ELEC
ELECTRICAL:
E ALL ELECTRICAL
SHEET TYPE DESIGNATOR
0 GENERAL
1 LIGHTING PLANS
2 POWER PLANS
3 GROUNDING & LIGHTNING PROTECTION PLANS
4 ENLARGED PLANS AND ELEVATIONS
5 DETAILS
6 SCHEDULES
7 ONE-LINE DIAGRAMS
8 SEQUENCE OF OPERATIONS/CONTROLS
9 3D REPRESENTATIONS
BUILDING LEVEL
XX VARIES AT NON-PLANS
0L LOWER GROUND LEVEL
00 GROUND LEVEL
01 LEVEL 1
1i LEVEL 1 INTERSTITIAL
02 LEVEL 2
03 LEVEL 3
04 LEVEL 4
4i LEVEL 4 INTERSTITIAL
05 LEVEL 5
06 LEVEL 6
07 LEVEL 7
08 LEVEL 8
09 LEVEL 9
10 LEVEL 10
KEY PLAN AREA / ZONE
KEY PLAN AREA AS DESIGNATED BY:
ON THIS PLAN
LETTER DENOTES KEY PLAN AREA
NUMBER DENOTES KEY PLAN ZONE
USE 01, 02 ETC FOR DRAWINGS
IN A SEQUENCE FOR NON-PLANS THAT APPLY
TO MULTIPLE BUILDINGS
DRAWING SEQUENCE
USE A, B ETC FOR DRAWINGS
IN A SEQUENCE
B1
SHEET NUMBER LEGEND (NON-PLAN)
E E 3 01 B
DISCIPLINE DESIGNATOR
G GENERAL
H HAZARDOUS MATERIALS
V SURVEYING/MAPPING
B GEOTECHNICAL
C CIVIL
L LANDSCAPE
S STRUCTURAL
A ARCHITECTURAL
I INTERIORS
Q EQUIPMENT
F FIRE PROTECTION
P PLUMBING
D PROCESS
M MECHANICAL
E ELECTRICAL
T TELECOMM
LEVEL 2 DESIGNATOR - ELEC
ELECTRICAL:
E ALL ELECTRICAL
SHEET TYPE DESIGNATOR
0 GENERAL
1 NOT USED
2 NOT USED
3 SECTIONS
4 ENLARGED PLANS
5 DETAILS
6 SCHEDULES
7 DIAGRAMS
8 SEQUENCE OF OPERATIONS/CONTROLS
9 3D REPRESENTATIONS
SHEET SEQUENCE
01-99
KEY PLAN AREA
A NOT USED
B VA MEDICAL CENTER (VAMC)
C LAUNDRY FACILITY
D CENTRAL UTILITY PLAN (CUP)
E NORTH PARKING
F SOUTH PARKING
G MAINTENANCE BUILDING
H SMOKING SHELTERS
I NOT USED
J GUARD HOUSES
K WATER TOWER
L ELECTRICAL SERVICE BUILDINGS
M BUS SHELTER
B1 B2 B3
B4 B5 B6
C2 D1
G1
J1
J2
K2
L1
L2
M1
D2
C1
E1 E2
E3 E4
F1 F2
F3 F4
B1E
B4F
B4E
N2
P
N1
K1
P lo t D at e th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
CONSTRUCTION DOCUMENTS - FULLY SPRINKLERED
URS | SMITHGROUP JOINT VENTURE
500 WEST JEFFERSON ST.
Suite 1600
LOUISVILLE, KY 40202
T 313.983.3600
F 313.983.3636 www.urscorp.com | www.smithgroupjjr.com
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Drawing Number
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Office of Facilities
Management
B
A
C
D
E
F
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
TRUE NORTH
PROJECT NORTH
97 8654321 o n e s ix te e n th in c h o n e fo o t o n e th ir ty s e c o n d th in c h o n e fo o t
PROJECT # 14576907/22200.000
OFFICE OF CONSTRUCTION & FACILITIES MANAGEMENT - CENTRAL REGION
3001 GREEN BAY ROAD
BUILDING 48
NORTH CHICAGO, IL 60064
T 224.610.3492
U.S. DEPARTMENT OF VETERANS AFFAIRS
SHEET INDEX ID:
USACE LOUISVILLE DISTRICT
600 DR. MARTIN LUTHER KING PLACE
LOUISVILLE, KY 40202
PHONE: 502-315-6766
FAX: 502-315-6195
CONTRACTING DIVISION
OrientationSeal
CERTIFIED FINAL
Mark
1/
/2
9:
:1
A
M
11JAN2021
EE000F
ELECTRICAL BUILDING AREA
DESIGNATION PLAN
BJW TES
Louisville, Kentucky
REPLACEMENT VA MEDICAL CENTER
VA Project No. 603-320 USACE P2 No. 453413
0.15.1.E0-EE000F-Phase B-ELECTRICAL
SCALE: 1" = 60'-0"
ELECTRICAL BUILDING AREA
DESIGNATION PLAN PROJECT NORTH
PHA CERTIFIED FINAL 20NOV2020
AMENDMENT 0003 1 11JAN2021
W
2Q R
R
-0
XX- X -XXX
PREFIX
SYSTEM
ELECTRICAL EQUIPMENT NAMING CONVENTION KEY
PREFIX
ATS
CB
DS
GEN
MCC
PDU
SGL
SGM
SWB
T
US
UPS
DESCRIPTION
AUTOMATIC TRANSFER SWITCH
CIRCUIT BREAKER DISCONNECT
DISCONNECT SWITCH
GENERATOR
MOTOR CONTROL CENTER
POWER DISTRIBUTION UNIT
LOW VOLTAGE SWITCHGEAR
MEDIUM VOLTAGE SWITCHGEAR
SWITCHBOARD
TRANSFORMER
UNIT SUBSTATION
UNINTERRUPTIBLE POWER SUPPLY
SYSTEM
C
EM
E L N U
DESCRIPTION
CRITICAL
EMERGENCY
EQUIPMENT
LIFE SAFETY
NORMAL
UNINTERRUPTIBLE POWER SUPPLY
BUILDING
A
BE
BW
C D E F G H J K L M
DESCRIPTION
VBA
VAMC (HSPL) - EAST BAR
VAMC (HSPL) - WEST BAR
LAUNDRY FACILITY
CENTRAL UTILITY PLANT (CUP)
NORTH PARKING STRUCTURE
SOUTH PARKING STRUCTURE
MAINTENANCE BUILDING
SMOKING SHELTERS
GUARD HOUSES
WATER TOWER
ELECTRICAL SERVICE BUILDINGS
BUS STRUCTURE
C RP 1 B1 A
SYSTEM
TYPE
LETTER ID
BUILDING / BUILDING AREA
(B1, B2, ETC. FOR HOSPITAL)
LEVEL
PANELBOARD NAMING CONVENTION KEY
TYPE
DP
LP
RP
PP
LCP
IP
DESCRIPTION
DISTRIBUTION PANELBOARD
LIGHTING PANELBOARD
RECEPTACLE PANELBOARD
POWER PANELBOARD
LIGHTING CONTROL PANEL
ISOLATED POWER PANEL
SYSTEM
BLANK
C
EM
E L U I
DESCRIPTION
NORMAL BRANCH
CRITICAL BRANCH
EMERGENCY BRANCH
EQUIPMENT BRANCH
LIFE SAFETY BRANCH
UNINTERRUPTIBLE POWER SUPPLY
INVERTER / BATTERY
BUILDING
A B C D E F G H
JE
JW
K
LE
LW
M P S
DESCRIPTION
VBA
VAMC (HSPL)
LAUNDRY FACILITY
CENTRAL UTILITY PLANT (CUP)
NORTH PARKING STRUCTURE
SOUTH PARKING STRUCTURE
MAINTENANCE BUILDING
SMOKING SHELTERS
GUARD HOUSE, EAST
GUARD HOUSE, WEST
WATER TOWER
ELECTRICAL SERVICE BUILDING, EAST
ELECTRICAL SERVICE BUILDING, WEST
BUS STRUCTURE
PUMP HOUSE
SITE
LEVEL
U L 1i 4i
DESCRIPTION
UNDERGROUND
LOWER GROUND LEVEL
GROUND LEVEL
LEVEL 1
LEVEL 1 INTERSTITIAL
LEVEL 2
LEVEL 3
LEVEL 4
LEVEL 4 INTERSTITIAL
LEVEL 5
LEVEL 6
LEVEL 7
LETTER ID
BUILDING / BUILDING AREA
(B1, B2, ETC. FOR HOSPITAL)
LEVEL
LEVEL
U L 1i 4i
DESCRIPTION
UNDERGROUND
LOWER GROUND LEVEL
GROUND LEVEL
LEVEL 1
LEVEL 1 INTERSTITIAL
LEVEL 2
LEVEL 3
LEVEL 4
LEVEL 4 INTERSTITIAL
LEVEL 5
LEVEL 6
LEVEL 7
LETTER ID
A, B, C,...
M-1, M-2, M-3,...
DESCRIPTION
TYPICAL SEQUENCE
MCR PANELBOARD SEQUENCE
C IP
SYSTEM
TYPE
ROOM NUMBER
(ALL ROOMS ARE ON
FOURTH FLOOR)
ISOLATED POWER PANEL NAMING CONVENTION KEY
FEEDER SCHEDULE - COPPER
1N
MAXIMUM
OCPD
FEEDER
NUMBER
NUMBER
OF SETS PHASE(3/C)
NEUTRAL
EQUIPMENT
GROUND
CONDUIT
SIZE
15 / 20
1 12 12 3/4"
2N 25 / 30
10 10 3/4"
3N 35 / 40
8 10
4N 45 / 50
6 10
5N 60 / 70
4 8
6N
3 8
7N
2 8
8N
100 / 110 /
1 6
9N
1/0
1/0 6
10N
10 --
11N
11 --
12N
12 --
13N
13 --
14N
14 --
15N
15 --
16N
3/0
3/0
17N
4/0
4/0
18N
MAXIMUM
OCPD
FEEDER
NUMBER
NUMBER
OF SETS
CONDUIT
SIZE
2 250 1
19N
1/0
20N
1/0
21N
1/0
22N
2/0
23N
3 3/0
24N
4 4/0
25N
5 250
26N
6 350
27N
8 400
28N
10 500
29N
12 700
CONDUCTOR SIZE
PHASE(3/C)
NEUTRAL
EQUIPMENT
GROUND
CONDUCTOR SIZE
3/4"
1"
1-1/4"
3-1/2"
2"
2-1/2"
2-1/2"
3"
3"
3-1/2"
3"
3"
3"
3-1/2"
4"
3-1/2"
5"
1"
1-1/4"
1-1/2"
1-1/4"
1-1/2"
2/0
3/0
4/0
2/0
3/0
4/0
1-1/2"
2"
2"
2"
2"
2-1/2"
2-1/2"
2-1/2"
3"
3"
2"
2-1/2"
2-1/2"
3-1/2"
4"
3-1/2"
4"
3-1/2"
4"
3-1/2"
4"
3-1/2"
4"
4"
2"
20A #12 #12 3/4" 3/4"
OCPD SIZE PHASE/NEUTRAL GROUND 3W+GRD 4W+GRD
BRANCH CIRCUIT WIRING MINIMUM REQUIREMENTS
WIRE SIZE (AWG) CONDUIT SIZE
30A #10 #10 3/4" 3/4"
40A #8 #10 3/4" 3/4"
60A #4 #8 1" 1-1/4"
55A #6 #10 3/4" 1"
WHERE NOT INDICATED ON THE PLANS, BRANCH CIRCUIT CONDUCTORS AND CONDUITS
SHALL BE SIZED, AT MINIMUM, BASED ON THE SCHEDULE BELOW. BRANCH CIRCUIT
LENGTH SHALL BE LIMITED TO 75'-0" WHERE POSSIBLE. THE WIRING FOR ANY BRANCH
CIRCUIT EXCEEDING 75'-0" IN LENGTH SHALL BE UPSIZED TO MAINTAIN < 3% VOLTAGE
DROP.
# SIZE CONDUCTORS SIZE SIZE
M1 LG&E-CKT1 SGM-N-OLW 5" LG&E PROVIDES CABLE
M10 SGM-EM-1DA US-EM-7BWB 2 3 250 KCMIL
M11 SGM-EM-1DA US-EM-5BEA 2 3 250 KCMIL
M4 SGM-N-OLW SGM-N-1DUSS 2 5" 3 500 KCMIL
M5 SGM-N-OLE SGM-N-1DUSS 2 5" 3 500 KCMIL
M2 LG&E-CKT2 SGM-N-OLE 5"
M3 SGM-N-OLW SGM-N-OLE 2 5" 3 500 KCMIL #500 KCMIL
M6 SGM-N-1DUSS US-N-7BWB 2 3 250 KCMIL #250 KCMIL
M7 SGM-N-1DUSS US-N-5EPV 1 3 #2 AWG #2 AWG
M8 SGM-N-1DUSS US-N-5FPV 1 3 #2 AWG #2 AWG
M9 SGM-N-1DUSS US-N-5BEA 2 3 250 KCMIL
15 KV SITE FEEDER SCHEDULE
FEEDER FROM TO # OF SETS CONDUIT # OF 15 KV CONDUCTOR GROUND REMARKS
LG&E PROVIDES CABLE
CONTRACTOR INSTALLS CABLE
CONTRACTOR INSTALLS CABLE
#500 KCMIL
#500 KCMIL
5"
5"
5"
5"
5"
5"
#250 KCMIL
#250 KCMIL
#250 KCMIL
P12 EDP1EA EMRP0JEA 1 1.25" 3 4/0 AWG 4 AWG
SIZE CONDUCTORS SIZE SIZE
P1 US-N-1DA DP1EA 5 4" 4 600 KCMIL 250 KCMIL
P6 US-EM-1DA-A ATS-E-1FA 3 4" 4 600 KCMIL 3/0 AWG
P7 US-EM-1DA-A ATS-E-1FA 1 2.5" 4 250 AWG 4 AWG
P8 US-EM-1DA-A FIRE PUMP PUMP HOUSE 2 3" 3 350 KCMIL 1/0 AWG
P9 EDP1EA WATER TOWER 1 1.25" 3 3 AWG 8 AWG
P2 US-N-1DA DP1FA 3 4" 4 600 KCMIL 250 KCMIL
P3 US-N-1DB-A PP0G1A 1 2" 4 3/0 AWG 2 AWG
P4 US-EM-1DA-A ATS-L-1EA 2 2.5" 4 4/0 AWG 2 AWG
P5 US-EM-1DA-A ATS-E-1EA 4 4" 4 600 KCMIL 3/0 AWG
P10 EDP1EA EMRP0LEA 1 2.5" 3 4/0 AWG 4 AWG
P11 EDP1EA EMRP0LWA 1 1.25" 3 4/0 AWG 4 AWG
SITE POWER FEEDER SCHEDULE
FEEDER FROM TO # OF SETS CONDUIT # OF 600V CONDUCTOR GROUND REMARKS
P13 EDP1EA EMPP0PA 1 3" 4 350 KCMIL 3 AWG
P14 US-EM-1DA-A FIRE PUMP HOUSE 2 3" 3 350 KCMIL 1/0 AWG
P lo t D at e th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
CONSTRUCTION DOCUMENTS - FULLY SPRINKLERED
URS | SMITHGROUP JOINT VENTURE
500 WEST JEFFERSON ST.
Suite 1600
LOUISVILLE, KY 40202
T 313.983.3600
F 313.983.3636 www.urscorp.com | www.smithgroupjjr.com
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Drawing Number
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Office of Facilities
Management
B
A
C
D
E
F
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
TRUE NORTH
PROJECT NORTH
97 8654321 o n e s ix te e n th in c h o n e fo o t o n e th ir ty s e c o n d th in c h o n e fo o t
PROJECT # 14576907/22200.000
OFFICE OF CONSTRUCTION & FACILITIES MANAGEMENT - CENTRAL REGION
3001 GREEN BAY ROAD
BUILDING 48
NORTH CHICAGO, IL 60064
T 224.610.3492
U.S. DEPARTMENT OF VETERANS AFFAIRS
SHEET INDEX ID:
USACE LOUISVILLE DISTRICT
600 DR. MARTIN LUTHER KING PLACE
LOUISVILLE, KY 40202
PHONE: 502-315-6766
FAX: 502-315-6195
CONTRACTING DIVISION
OrientationSeal
CERTIFIED FINAL
Mark
1/
/2
9:
:0
A
M
11JAN2021
EE002
ELECTRICAL SYMBOLS AND
ABBREVIATIONS, PART 2
BJW TES
Louisville, Kentucky
REPLACEMENT VA MEDICAL CENTER
VA Project No. 603-320 USACE P2 No. 453413
0.15.1.E0-EE002-Phase B-ELECTRICAL
PHA CERTIFIED FINAL 20NOV2020
AMENDMENT 0003 1 11JAN2021
W
2Q R
R
-0
P lo t D at e th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
CONSTRUCTION DOCUMENTS - FULLY SPRINKLERED
URS | SMITHGROUP JOINT VENTURE
500 WEST JEFFERSON ST.
Suite 1600
LOUISVILLE, KY 40202
T 313.983.3600
F 313.983.3636 www.urscorp.com | www.smithgroupjjr.com
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Drawing Number
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Office of Facilities
Management
B
A
C
D
E
F
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321 o n e s ix te e n th in c h o n e fo o t o n e th ir ty s e c o n d th in c h o n e fo o t
PROJECT # 14576907/22200.000
OFFICE OF CONSTRUCTION & FACILITIES MANAGEMENT - CENTRAL REGION
3001 GREEN BAY ROAD
BUILDING 48
NORTH CHICAGO, IL 60064
T 224.610.3492
U.S. DEPARTMENT OF VETERANS AFFAIRS
SHEET INDEX ID:
USACE LOUISVILLE DISTRICT
600 DR. MARTIN LUTHER KING PLACE
LOUISVILLE, KY 40202
PHONE: 502-315-6766
FAX: 502-315-6195
CONTRACTING DIVISION
Orientation
1/ 7/
1:
:4
A
M
11JAN2021
EE643
LIGHTING FIXTURE SCHEDULE
BJW KAP
Louisville, Kentucky
REPLACEMENT VA MEDICAL CENTER
VA Project No. 603-320 USACE P2 No. 453413
-1.15.2.E2-EE643-Phase B-ELECTRICAL
ELECTRICAL LIGHTING FIXTURE SCHEDULE 4
TYPE LAMPS VOLTAGE MANUFACTURER SERIES DESCRIPTION REMARKS
XL12 24W/LED UNV BEGA
OR APPROVED EQUAL
77 917 21" X 3.5" IP68 RATED RECESSED INGRADE LED UPLIGHT, FLUSH
MOUNTING, STAINLESS STEEL TRIM, SAFETY GLASS LENS, DRIVER OVER
RATED ASSEMBLY, WALLWASH OPTIC, HIGH TEMP SILICONE GASKETS,
18"L x 6.25"W x 11.5"H RECESSED POLYMER HOUSING, INTEGRAL DRIVER, 4000K COLOR TEMPERATURE, 1350 DELIVERED LUMENS.
XL13 2.7W/LED UNV BEGA
OR APPROVED EQUAL
33018 10.1L x 5"W x 2.75"H IP65 RATED RECESSED STEP LIGHT, LOUVERED
FACE PLATE, MARINE GRADE DIE-CAST ALUMINUM HOUSING, WHITE
SAFETY GLASS LENS, HIGH TEMP SILICONE GASKETS, TAMPER
RESISTANT HARDWARE, STAINLESS STEEL SCREWS THREADED INTO
STAINLESS STEEL INSERTS, UV RESISTANT POWDER COAT FINISH,
4000K COLOR TEMP, 44 LUMENS. MANUFACTURER PROVIDED CUSTOM
TAMPER PROOF HARDWARE AND ACRYLIC LENS.
XL13A 2.1W/LED UNV BEGA
OR APPROVED EQUAL
22203 3.1L x 4"W x 3.1"H IP65 RATED RECESSED STEP LIGHT, LOUVERED FACE
PLATE, MARINE GRADE DIE-CAST ALUMINUM HOUSING, WHITE SAFETY
GLASS LENS, HIGH TEMP SILICONE GASKETS, STAINLESS STEEL
SCREWS THREADED INTO STAINLESS STEEL INSERTS, UV RESISTANT
POWDER COAT FINISH, 4000K COLOR TEMP, 44 LUMENS.
PROVIDE REMOTE ELECTRONIC DRIVER. CONTRACTOR TO COORDINATE LOCATION
AND CONCEALMENT OF DRIVER FOR FINAL APPROVAL BY ARCHITECT.
XL14 7W/LED UNV B-K LIGHTING
OR APPROVED EQUAL
TWIN STAFF STAR
STYLE C LED
2 1/4" DIAMETER x 4 1/2"L IP66 RATED ADJUSTABLE LED FLOOD LIGHT, MARINE GRADE ALUMINUM BODY, 360 DEGREE ROTATION AND 180
DEGREE TILT, SILICONE O-RING GASKETS, INTEGRAL POTENTIOMETER
DIMMING CONTROL, REMOTE TRANSFORMER, INTERCHANGEABLE
OPTICS, 31 DEGREE FLOOD DISTRIBUTION, BLACK HEXCELL LOUVER,
2.25" / 45 DEGREE SNOOT, UV RESISTANT POWDER COAT FINISH, 4000K
COLOR TEMPERATURE. 3' HEIGHT, 18" POWER PIPE, STABILITY FLANGE.
PROVIDE REMOTE POWER SUPPLY.
XL15 28W/LED UNV WE-EF OR APPROVED EQUAL 662-3124+665-8139+662-
6.1 DIAMETER x 2.76"W x 10"H IP66 ADJUSTABLE RAIL MOUNTED LED
FLOOD LIGHT, MARINE GRADE DIE-CAST ALUMINUM BODY, POLYMER
COATED STAINLESS STEEL HARDWARE, UV RESISTANT POWDER COAT
FINISH, SILICONE GASKETS, IK07 RATED, CLEAR TEMPERED GLASS
LENS, MEDIUM BEAM WITH LINEAR BEAM SPREAD OPTIC, INTEGRAL
DIMMING DRIVER, MANUFACTURER PROVIDED RAIL SYSTEM AND
FIXTURE RAIL MOUNTING CLAMPS, 4000K COLOR TEMPERATURE, 2327
DELIVERED LUMENS. FIXTURE TO HAVE OVAL BEAM DISTRIBUTION AND
AIMED 25 DEGREES ABOVE HORIZON. MANUFACTURER PROVIDED RAIL
MOUNTING SYSTEM WITH 3 MAINS OUTLETS ON 5'4" RAIL.
PROVIDE UPRIGHT ATTACHMENTS AND CLAMP FOR POLE. AIMING AND DIMMING OF
EACH FIXTURE TO BE PREFORMED ON SITE IN PRESENCE OF ARCHITECT IN NIGHT
TIME ENVIRONMENT.
XL15A 28W/LED UNV WE-EF OR APPROVED EQUAL 662-3124 + 665-8139 +
662-9363
SAME AS XL15 EXCEPT RAIL MOUNTING SYSTEM WITH 6 MAINS OUTLETS
ON 7'-0" RAIL.
PROVIDE UPRIGHT ATTACHMENTS AND CLAMP FOR POLE. AIMING AND DIMMING OF
EACH FIXTURE TO BE PREFORMED ON SITE IN PRESENCE OF ARCHITECT IN NIGHT
TIME ENVIRONMENT.
XL16 62W/LED UNV LUMENPULSE
OR APPROVED EQUAL
LUMENFACADE LINEAR FACADE LED FIXTURE, EXTRUDED ALUMINUM HOUSING, IP66
RATED, 3592 LUMENS, 4000K COLOR TEMPERATURE, CRI 80
ASYMMETRIC WALLWASH OPTIC, END-TO-END CONFIGURATION, 0-10V
DIMMING DRIVER, BLACK SANDTEX COLOR. WET LOCATION LISTED.
49.375"(L) X 2.1875"(W) X 4.3125"(D).
XL17 27W/LED UNV USAI
OR APPROVED EQUAL
BEVELED MICRO
DOWNLIGHT FLANGE
10"L x 1.25"W APERTURE, WET LOCATION LISTED FLANGED 8 CELL LED
DOWNLIGHT, 50 DEGREE BEAM, BLACK MATTE BEVEL AND FLANGE
FINISH, 3500K COLOR TEMPERATURE, INTEGRAL DRIVER HOUSING, 1600
DELIVERED LUMENS.
FIELD REPLACEABLE LED LIGHT ENGINE AND DRIVER FROM BELOW CEILING,
THROUGH LIGHT APERTURE.
XL17A 21W/LED UNV USAI
OR APPROVED EQUAL
BEVELED MICRO
DOWNLIGHT FLANGE
7.5"L x 1.25"W APERTURE, 6 CELL, WET LOCATION LISTED FLANGED 8
CELL LED DOWNLIGHT, 50 DEGREE BEAM, BLACK MATTE BEVEL AND
FLANGE FINISH, 3500K COLOR TEMPERATURE, INTEGRAL DRIVER
HOUSING, 1225 DELIVERED LUMENS.
FIELD REPLACEABLE LED LIGHT ENGINE AND DRIVER FROM BELOW CEILING THROUGH
LIGHT APERTURE.
XL17B 13W/LED UNV USAI
OR APPROVED EQUAL
BEVELED MICRO
DOWNLIGHT FLANGE
5"L x 1.25"W APERTURE, 4 CELL, WET LOCATION LISTED FLANGED 8 CELL
LED DOWNLIGHT, 50 DEGREE BEAM, BLACK MATTE BEVEL AND FLANGE
FINISH, 3500K COLOR TEMPERATURE, INTEGRAL DRIVER HOUSING, 1225
DELIVERED LUMENS.
FIELD REPLACEABLE LED LIGHT ENGINE AND DRIVER FROM BELOW CEILING THROUGH
LIGHT APERTURE.
XL18 12W/LED UNV WE-EF
OR APPROVED EQUAL
611-2326+665-8232 ROUND LED INGRADE LANDSCAPE LIGHT, BLACK POLYMER HOUSING,
FLUSH MOUNT, HEXCELL LOUVER, 1299 LUMENS, 3000K COLOR
TEMPERATURE.
XL20 5W/LED UNV ECOSENSE
OR APPROVED EQUAL
TROVE L50
ASYMMETRIC
1.64"W x 2.14"H IP66 RATED LINEAR LED ADJUSTABLE ACCENT LIGHT, ASYMETRIC BEAM OPTIC, EXTRUDED ALUMINUM HOUSING, POLYCARBONATE LENS, STAINLESS STEEL FASTENERS, RUBBER
GASKETS, 0-180 DEGREES AIMING IN 15 DEGREE LOCKING INCREMENTS,
ALUMINUM FINE ADJUSTMENT MOUNTING BRACKET, 4000K COLOR
TEMPERATURE, 302 LUMENS.FT.
COORDINATE EXACT LENGTH WITH ARCHITECTURAL DRAWINGS AND DETAILS
XL20A 12W/LED UNV ECOSENSE
OR APROVED EQUAL
TROVE L50 GRAZE 1.64"W x 2.14"H IP66 RATED LINEAR LED ADJUSTABLE ACCENT LIGHT, 9 DEGREE x 29 DEGREE BEAM OPTIC, EXTRUDED ALUMINUM HOUSING, POLYCARBONATE LENS, STAINLESS STEEL FASTENERS, RUBBER
GASKETS, 0-180 DEGREES AIMING IN 15 DEGREE LOCKING INCREMENTS,
ALUMINUM FINE ADJUSTMENT MOUNTING BRACKET, 4000K COLOR
TEMPERATURE, 923 LUMENS.FT.
COORDINATE EXACT LENGTH WITH ARCHITECTURAL DRAWINGS AND DETAILS
XL21 31W/LED UNV BEGA
OR APPROVED EQUAL
88064 6.6" DIAMETER x 14'-9"H LED POST LIGHT, IP65 RATED, DIE-CAST MARINE
GRADE ALUMINUM HOUSING, CLEAR POLYCARBONATE DIFFUSER AND
ANODIZED ALUMINUM REFLECTOR, SILICONE RUBBER GASKETS,
INTEGRAL DIMMING DRIVER, 3MIL THICK POLYESTER UV RESISTANT
POWDER COAT FINISH, 4000K COLOR TEMPERATURE, SYMMETRIC
DISTRIBUTION, 3383 DELIVERED LUMENS.
XL21A 31W/LED UNV BEGA
OR APPROVED EQUAL
88067 6.6" DIAMETER x 14'-9"H LED POST LIGHT, IP65 RATED, DIE-CAST MARINE
GRADE ALUMINUM HOUSING, CLEAR POLYCARBONATE DIFFUSER AND
ANODIZED ALUMINUM REFLECTOR, SILICONE RUBBER GASKETS,
INTEGRAL DIMMING DRIVER, 3MIL THICK POLYESTER UV RESISTANT
POWDER COAT FINISH, 4000K COLOR TEMPERATURE, TYPE 2
DISTRIBUTION, 3294 DELIVERED LUMENS.
XL22 9W UNV ERCO OR APPROVED EQUAL KONA XS PROJECTOR 5 5/16"L x 3 1/8" DIAMETER x 6 7/8"H, IP65 RATED ADJUSTABLE LED SPOT
LIGHT, 4000K COLOR TEMPERATURE, SURFACE MOUNTED, ALUMINUM
HOUSING, POWDER COAT FINISH, 130 DEGREE TILTABILITY, MOUNTING
PLATE ROTATE TO 350 DEGREE, SAFETY GLASS LENS, SPOT OPTIC, 680
LUMENS PER FOOT.
AIMING AND DIMMING OF EACH FIXTURE TO BE PERFORMED ON SITE IN PRESENCE
OF ARCHITECT OR ENGINEER IN NIGHT TIME ENVIRONMENT.
XL23 155W/LED UNV WE-EF OR APPROVED EQUAL 667-6425 TWIN HEAD LED POLE MOUNTED FLOOD LIGHT, DIE-CAST MARINE
GRADE ALUMINUM ALLOY HOUSING, SILICONE RUBBER GASKETS AND
STAINLESS STEEL HARDWARE, WIDE DISTRIBUTION, 6" DIAMETER TO 4"
DIAMETER, 15' ROUND, TAPERED ALUMINUM POLE AND BASE PLATE
COVER, SERVICE DOOR WITH TAMPER PROOF HARDWARE, UV
RESISTANT POWEDER COAT FINISH, IP66, IK08, 5CE, 4000K COLOR
TEMPERATURE, 17,200 DELIVERED LUMENS.
XL23A 155W/LED UNV WE-EF OR APPROVED EQUAL 667-6425 TRIPLE HEAD LED POLE MOUNTED FLOOD LIGHT, DIE-CAST MARINE
GRADE ALUMINUM ALLOY HOUSING, SILICONE RUBBER GASKETS AND
STAINLESS STEEL HARDWARE, WIDE DISTRIBUTION, 6" DIAMETER TO 4"
DIAMETER, 15' ROUND, TAPERED ALUMINUM POLE AND BASE PLATE
COVER, SERVICE DOOR WITH TAMPER PROOF HARDWARE, UV
RESISTANT POWDER COAT FINISH, IP66, IK08, 5CE, 4000K COLOR
TEMPERATURE, 17,200 DELIVERED LUMENS.
XL31A 39.6W/LED UNV BEGA
OR APPROVED EQUAL
77918 20.9"L x 3.5"W x 5" INGRADE LINEAR LED WALLWASH, IP67 RATED, MARINE
GRADE DIE-CAST ALUMINUM ENCLOSURE, STAINLESS STEEL INNER
HOUSING, FACE PLATE AND HARDWARE, TEMPERED MATTE SAFETY
GLASS, HIGH TEMPERATURE SILICONE GASKET, ALUMINUM REFLECTOR,
WATERPROOF CABLE GLAND ENTRY INTO HOUSING, BUSHED
STAINLESS STEEL FINISH, 4000K COLOR TEMPERATURE, 2480
DELIVERED LUMENS.
COORDINATE MOUNTING WITH ARCHITECTURAL AND STRUCTURAL DRAWINGS,
MOUNTED IN FLOOR SLAB
GENERAL NOTES
A. REFERENCES TO A PARTICULAR MANUFACTURERS PRODUCTS ARE INTENDED
AS A BASIS OF DESIGN. THE CONTRACTOR MAY PROVIDE EQUIPMENT THAT IS
AN APPROVED EQUAL. REFER TO DIV. 1 SPECIFICATIONS ON SUBSTITUTIONS.
PHB CERTIFIED FINAL 20NOV2020
ADDENDUM 0003 11JAN2021
Revisions: DateMark
PHA CERTIFIED FINAL 20NOV2020
AMENDMENT 0003 1 11JAN2021
W
2Q R
R
-0
STANDARD TELECOMMUNICATIONS OUTLET (TCO),
ONE (1) CAT 6A VOICE AND TWO (2) CAT 6A DATA
WALL MOUNTED, 18" AFF UNLESS OTHERWISE NOTED
X = NUMBER OF DATA CABLES AND ASSOCIATED JACKS
Y = DESIGNATION AA" = NON-STANDARD MOUNTING HEIGHT
Z = NUMBER OF VOICE CABLES AND ASSOCIATED JACKS
X Y Z
X A
X C
X F Z
X S Z
X D Z
X W Z
ABOVE CEILING TELECOMMUNICATIONS OUTLET (TCO) - CAT 6A DATA ONLY
CEILING MOUNTED TELECOMMUNICATIONS OUTLET (TCO) - CAT 6A DATA ONLY
FLOOR MOUNTED TELECOMMUNICATIONS OUTLET (TCO) -
CAT 6A VOICE AND DATA
SEE DRWAINGS FOR PATHWAY AND CABLE REQUIREMENTS
SURFACE MOUNTED TELECOMMUNICATIONS OUTLET (TCO) -
CAT 6A VOICE AND DATA
48" AFF UNLESS OTHERWISE NOTED ON PLANS
SYSTEM FURNITURE MOUNTED TELECOMMUNICATIONS OUTLET (TCO) -
CAT 6A VOICE AND DATA,
SEE DRWAINGS FOR PATHWAY AND CABLE REQUIREMENTS
SPECIAL SYSTEM OUTLET SYMBOLS
TV
M
ET
TELECOMMUNICATION SYMBOLS
TV OUTLET - RG6 COAX OUTLET - ("F" FITTING), RJ45 - CAT 6 DATA OUTLET (FMS
NETWORK) AND CONTROL JACK FROM PATIENT PILLOW SPEAKER (FOR PATIENT
ROOMS ONLY - TV CONTROL).
DESKTOP PA MICROPHONE
WALL MOUNTED TELECOMMUNICATIONS OUTLET (TCO) - CAT 6A VOICE AND DATA
18" AFF UNLESS OTHERWISE NOTED ON PLANS
ELAPSED TIME DIGITAL CLOCK WITH CONTROL STATION
W
DAS
CEILING MOUNTED ANTENNA FOR THE DISTRIBUTED ANTENNA SYSTEM (DAS)
NL
NL
ND
NCB
NB
NE
NM
NP
NS
NURSE CALL BED RECEPTACLE
NURSE CALL LED MULTI-SEGMENT DOME/ZONE LIGHT, CEILING MOUNTED,
NL=CORRIDOR LIGHT, NZ=ZONE LIGHT
NURSE CALL DUTY STATION, MOUNTED 4'-0" UNLESS OTHERWISE NOTED ON
PLANS
NURSE CALL PULL CORD STATION. SHOWER LOCATION MOUNTED 6'-0", TOILET
AND EXAM LOCATIONS MOUNTED AT 4'-0" UNLESS OTHERWISE NOTED ON PLANS.
PULL CORD TO BE 2" OFF THE FLOOR.
NURSE CALL MASTER STATION - DESK MOUNTED
NURSE CALL PATIENT STATION WITH INTEGRATED NORMAL CALL, STAFF ASSIST
CALL AND CODE BLUE CALL. MOUNTED IN HEADWALL UNLESS OTHERWISE NOTED
NURSE CALL AUDIO VISUAL STAFF STATION WITH CODE BLUE BUTTON, MOUNTED
AT 4'-0" UNLESS OTHERWISE NOTED ON PLANS.
NURSE CALL CODE BLUE STATION - STAND ALONE. MOUNTED ADJACENT TO
PATIENT AND STAFF STATIONS UNLESS THE HAVE A CODE BLUE BUTTON
ALREADY.
NURSE CALL STAFF RTLS STATION (IR IN ALL PATIENT ROOMS, RF IN ALL
CORRIDORS) ROUGH-IN ONLY. 3RD PARTY SYSTEM - MUST INTERFACE WITH
NURSE CALL SYSTEM)
NURSE CALL LED MULTI-SEGMENT DOME/ZONE LIGHT, WALL MOUNTED 7'-0"
UNLESS OTHERWISE NOTED,
NL=CORRIDOR LIGHT, NZ=ZONE LIGHT
NURSE CALL SYSTEM SYMBOLS
NST
NURSE CALL STAFF TERMINAL MOUNTED AT 48" UNLESS OTHERWISE NOTED ON
PLANS. PROVIDES PROGRAMMABLE TROUBLE FUNCTIONS FOR NURSE CALL AND
CODE BLUE IN THE POLICE OPS ROOM, 1B1501.
SX
CLINICAL CAMERA JUNCTION BOX, CEILING MOUNTEDCJ
SP
V
SP
SP
SPEAKER - GENERAL PA CEILING MOUNTED. XXX = THREE LETTER ZONE
ASSIGNMENT TO MATCH AMPLIFIER ZONES IN TR.
SPEAKER - GENERAL PA CEILING MOUNTED WITH VOLUME CONTROL. XXX =
THREE LETTER ZONE ASSIGNMENT TO MATCH AMPLIFIER ZONES IN TR.
SPEAKER - WALL MOUNTED, HORN TYPE. XXX = THREE LETTER ZONE
ASSIGNMENT TO MATCH AMPLIFIER ZONES IN TR. MOUNT AT 84" AFF UNLESS
OTHERWISE NOTED
SP
M
SPEAKER - SOUND MASKING SPEAKER - MOUNTED ABOVE CEILING IN PLENUM
SPACE. PROVIDE AMPLIFIER AND EQUALIZER FOR EACH IDENTIFIED ZONE.
CR1
CR2
DP
MD
ACCESS CONTROL CARD READER, NO KEYPAD
ACCESS CONTROL CARD READER WITH KEYPAD, DUAL AUTHORIZATION
DURESS/PANIC SWITCH WALL MOUNTED. " L" INDICATES LOCK SWITCH. WALL
MOUNTED AT 4'-0" UNLESS OTHERWISE NOTED.
DOOR OPERATING EQUIPMENT
MOTION DETECTOR WALL MOUNTED
DO
DC DOOR CONTACT
DP
DURESS/PANIC SWITCH UNDER COUNTER TOP OR DESK MOUNTED. " L" INDICATES
LOCK SWITCHL
L
SECURITY ACCESS CONTROL AND EPSS SYSTEM
IS
OR
IM
OR
IS
IM
INTERCOM MASTER STATION, DEDICATED TO SURGERY SUITE, WALL MOUNTED
4'-0" UNLESS OTHERWISE NOTED ON PLANS.
INTERCOM STATION, DEDICATED TO SURGERY SUITE, WALL MOUNTED 4'-0"
UNLESS OTHERWISE NOTED ON PLANS. MUST BE ANTI-MICROBIAL RATED
POLICE SECURITY PHONE MASTER STATION, DESK MOUNTED MOUNTED UNLESS
OTHERWISE NOTED ON PLANS.
SECURITY CALL STATION, WALL MOUNTED 4'-0" UNLESS OTHERWISE NOTED ON
PLANS. CALLS POLICE SECURITY COMMAND CENTER MASTER
EMERGENCY CALL STATION PEDESTAL MOUNTED WITH CAMERA
INTERCOM SYSTEMS
N P
NURSE CALL PILLOW SPEAKER. PROVIDE WITH ALL NURSE CALL PATIENT
STATIONS. MUST BE ABLE TO CONTROL THE PATIENT TV.
X "X" INDICATES: WP=MOUNT AT 46" AFF; IF "X" IS NOT INDICATE THEN MOUNT 18" AFF
WALL MOUNTED RECESSED JUNCTION BOX
W
OIT
WIRELESS ACCESS POINT (WAP) CEILING MOUNTED,
OIT DEPARTMENT WIRELESS ACCESS POINT - CLINICAL NETWORK
W
FMS
WIRELESS ACCESS POINT (WAP) CEILING MOUNTED,
FMS DEPARTMENT WIRELESS ACCESS POINT - VISITOR NETWORK
XXX
XXX
XXX
EP
EP
PEDESTAL AND WALL MOUNTED EMERGENCY CALL STATION
C1
CAMERA TYPE CAMERA DESIGN TYPE
STANDARD RESOLUTION, WALL OR
CEILING MOUNT NETWORK CAMERA
C2
C3
C4
C5
C6
HIGH RESOLUTION, WALL OR CEILING
MOUNT NETWORK CAMERA (USE FOR
FACIAL RECOGNITION PURPOSES)
STANDARD RESOLUTION, WALL OR
CEILING MOUNT P-T-Z NETWORK CAMERA
STANDARD RESOLUTION, WALL, POLES
OR CEILING MOUNT P-T-Z NETWORK
CAMERA
STANDARD RESOLUTION, CEILING MOUNT
FISHEYE NETWORK CAM. - 360 DEG.
HIGH RESOLUTION, WALL OR CEILING
MOUNT NETWORK CAMERA (USE FOR
LICENSE PLATE READING OR IDENTIFY)
C
MULTI-HEAD, MULTI - POSITION, 4 WAY
OMNI VIEW NETWORK CAMERA
CAMERA DESCRIPTION
INDOOR DOME, FIXED POSITION NETWORK
CAMERA WITH VERI-FOCAL LENS
INTERIOR PAN-TILT-ZOOM
NETWORK DOME CAMERA
ENVIRONMENTAL EXTERIOR
PAN-TILT-ZOOM NETWORK
DOME CAMERA W/MOUNT
INDOOR DOME, FISHEYE NETWORK CAMERA
WITH PANORAMIC LENS
ENVIRONMENTAL, EXTERIOR FIXED POSITION,
NETWORK VANDAL RES., DOME CAMERA.
FOUR HEAD, MULTI-POSITION CAMERA WITH
SINGLE NETWORK CONNECTION. COORDINATE
WITH PUBLIC SAFETY FOR CAMERA VIEWS.
CAMERA RESOLUTION
(MINIMUM)
2 MP
5 MP
1 MP
2 MP
1 MP
5 MP
MOUNTING TYPE
CEILING OR WALLS (WITH WALL
MOUNT ADAPTER)
CEILING OR WALLS (WITH WALL
MOUNT ADAPTER)
CEILING OR WALLS (WITH WALL
MOUNT ADAPTER)
WALLS, OR CEILINGS (WITH
WALL MOUNT ADAPTER)
WALLS, CEILINGS, POLES (WITH
WALL MOUNT ADAPTER)
WALLS, CEILINGS, POLES
(WITH WALL MOUNT ADAPTER)
LENS TYPE
VERI-FOCAL LENS 3.0 TO
10.5 MM
VERI-FOCAL LENS 3.0 TO
10.5 MM
5X OPTICAL
10X DIGITAL
32X OPTICAL
12X DIGITAL
1.27 MM - FISHEYE LENS
VERI-FOCAL LENS 3.5 TO
10.5 MM
4 EACH 2.8 - 6.0 MM
VARIFOCAL LENS
POWER TYPE
POE POWERED
POE POWERED
POE POWERED
POE POWERED
POE POWERED
FIBER CABLE (MM OR SM) W/
FIBER CONVERTER)
NOT REQUIRED
NOT REQUIRED
NOT REQUIRED
NOT REQUIRED
CCTV CAMERA MATRIX
INTERIOR - NOT REQUIRED,
REQUIRED FOR POLE MOUNT
LONG DISTANCE CAMERAS
INDOOR DOME, FIXED POSITION NETWORK
CAMERA WITH VERI-FOCAL LENS
8 MP
REFER TO SPECIFICATION SECTION 281300 AND THE ROUGH-IN REQUIREMENTS
ON SHEETS TC705 AND TC706
REFER TO SPECIFICATION SECTION 281300 AND THE ROUGH-IN REQUIREMENTS
ON SHEETS TC705 AND TC706
REFER TO SPECIFICATION SECTION 281300 AND THE ROUGH-IN REQUIREMENTS
ON SHEETS TC705 AND TC706
REFER TO SPECIFICATION SECTION 281300 AND THE ROUGH-IN REQUIREMENTS
ON SHEETS TC705 AND TC706
REFER TO SPECIFICATION SECTION 281600 FOR INFORMATION
REFER TO SPECIFICATION SECTION 282600 FOR INFORMATION
REFER TO SPECIFICATION SECTION 282600 FOR INFORMATION
REFER TO SPECIFICATION SECTION 285231 FOR INFORMATION
REFER TO SPECIFICATION SECTION 285231 FOR INFORMATION
REFER TO SPECIFICATION SECTION 275123 FOR INFORMATION
REFER TO SPECIFICATION SECTION 275123 FOR INFORMATION
REFER TO SPECIFICATION SECTION 285231 AND SHEET TC511 FOR CONNECTIVITY INFORMATION
REFER TO SPECIFICATION SECTION 275223 AND PARTIAL SCHEMATIC
DESIGN ON SHEET TC502. REFER TO ARCHITECTURAL VOLUMES FOR MOUNTING INFORMATION.
REFER TO SPECIFICATION SECTION 275223 AND PARTIAL SCHEMATIC
DESIGN ON SHEET TC502. REFER TO ARCHITECTURAL VOLUMES FOR MOUNTING INFORMATION.
REFER TO SPECIFICATION SECTION 275223 AND PARTIAL SCHEMATIC
DESIGN ON SHEET TC502. REFER TO ARCHITECTURAL VOLUMES FOR MOUNTING INFORMATION.
REFER TO SPECIFICATION SECTION 275223 AND PARTIAL SCHEMATIC
DESIGN ON SHEET TC502. REFER TO ARCHITECTURAL VOLUMES FOR MOUNTING INFORMATION.
REFER TO SPECIFICATION SECTION 275223 AND PARTIAL SCHEMATIC
DESIGN ON SHEET TC502. REFER TO ARCHITECTURAL VOLUMES FOR MOUNTING INFORMATION.
REFER TO SPECIFICATION SECTION 275223 AND PARTIAL SCHEMATIC
DESIGN ON SHEET TC502. REFER TO ARCHITECTURAL VOLUMES FOR MOUNTING INFORMATION.
REFER TO SPECIFICATION SECTION 275223 AND PARTIAL SCHEMATIC
DESIGN ON SHEET TC502. REFER TO ARCHITECTURAL VOLUMES FOR MOUNTING INFORMATION.
REFER TO SPECIFICATION SECTION 275223 AND PARTIAL SCHEMATIC DESIGN ON SHEET TC502.
ALL CEILING MOUNTED DEVICES MUST BE CENTERED ON THE ASSOCIATED CEILING TILE.
REFER TO SPECIFICATION SECTION 275223 AND PARTIAL SCHEMATIC DESIGN ON SHEET TC502.
ALL CEILING MOUNTED DEVICES MUST BE CENTERED ON THE ASSOCIATED CEILING TILE.
REFER TO SPECIFICATION SECTION 275223 AND PARTIAL SCHEMATIC DESIGN ON SHEET TC502.
ALL CEILING MOUNTED DEVICES MUST BE CENTERED ON THE ASSOCIATED CEILING TILE.
REFER TO SPECIFICATION SECTION 275223 AND PARTIAL SCHEMATIC
DESIGN ON SHEET TC502. REFER TO ARCHITECTURAL VOLUMES FOR MOUNTING INFORMATION.
REFER TO SPECIFICATION SECTION 275223 AND PARTIAL SCHEMATIC
DESIGN ON SHEET TC502. REFER TO ARCHITECTURAL VOLUMES FOR MOUNTING INFORMATION.
THIS CONTRACTOR SHALL PROVIDE ROUGH-IN ONLY. ALL EQUIPMENT WILL BE PROVIDED BY THE
ACTIVATION CONTRACTOR. ALL CEILING MOUNTED DEVICES MUST BE CENTERED ON THE
ASSOCIATED CEILING TILE.
T
TELECOMMUNICATIONS OUTLET FOR FOR POE POWERED CLOCK.
WALL MOUNTED AT 80" AFF UNLESS OTHERWISE NOTED ON PLANS
REFER TO SPECIFICATION SECTION 274131 AND PARTIAL SCHEMATIC
DESIGN ON SHEET TC512
REFER TO SPECIFICATION SECTION 275116 AND PARTIAL SCHEMATIC
DESIGN ON SHEET TC505 AND TC513
REFER TO SPECIFICATION SECTION 275116 AND PARTIAL SCHEMATIC DESIGN ON SHEET TC505 AND TC513. ALL CEILING MOUNTED DEVICES MUST BE CENTERED ON THE ASSOCIATED CEILING
TILE.
REFER TO SPECIFICATION SECTION 275116 AND PARTIAL SCHEMATIC
DESIGN ON SHEET TC505 AND TC513
REFER TO SPECIFICATION SECTION 275116.
REFER TO SPECIFICATION SECTION 275241 AND PARTIAL SCHEMATIC
DESIGN ON SHEET TC704
REFER TO SPECIFICATION SECTION 275241 AND PARTIAL SCHEMATIC
DESIGN ON SHEET TC704
STANDARD TELECOMMUNICATIONS OUTLET (TCO),
TWO (2) CAT 6A DATA ONLY
WALL MOUNTED, 18" AFF UNLESS OTHERWISE NOTED
TELECOMMUNICATIONS OUTLET (TCO) FOR EMERGENCY
COMMUNICATIONS DEVICE. "AN" IS FOR AN ANALOG LINE FOR ELEVATOR
COMMUNICATION.
TELECOMMUNICATIONS OUTLET (TCO) FOR CLINICAL OR FMS SPECIFIC EQUIPMENT
ONE (1) DATA ONLY, WALL MOUNTED, 18" AFF UNLESS OTHERWISE NOTED
REFER TO SPECIFICATION SECTION 271500
REFER TO SPECIFICATION SECTION 285231. SEE DRAWINGS FOR SPECIFIC USE
REFER TO SPECIFICATION SECTION 271500.
SEE DRAWINGS FOR SPECIFIC USE, CABLING AND SPECIAL ROUGH-IN REQUIREMENTS
REEER TO SPECIFICATION SECTION 271500. PROVIDE STRUCTURED CABLING ONLY. WAP
ANTENNA SHALL BE PROVIDED BY THE ACTIVATION CONTRACTOR. ALL CEILING MOUNTED
DEVICES MUST BE CENTERED ON THE ASSOCIATED CEILING TILE.
COMMENTS COMMENTS
COMMENTS
COMMENTS
COMMENTS
COMMENTS
AA"
X D SYSTEM FURNITURE MOUNTED TELECOMMUNICATIONS OUTLET (TCO) -
CAT 6A DATA ONLY, SEE DRWAINGS FOR PATHWAY AND CABLE REQUIREMENTS
X W WALL MOUNTED TELECOMMUNICATIONS OUTLET (TCO) - CAT 6A DATA ONLY
18" AFF UNLESS OTHERWISE NOTED ON PLANS
X F
X S
FLOOR MOUNTED TELECOMMUNICATIONS OUTLET (TCO) -
CAT 6A DATA ONLY
SEE DRWAINGS FOR PATHWAY AND CABLE REQUIREMENTS
SURFACE MOUNTED TELECOMMUNICATIONS OUTLET (TCO) -
CAT 6A DATA ONLY
48" AFF UNLESS OTHERWISE NOTED ON PLANS
E
J
REFER TO SPECIFICATION SECTION 275319 AND PARTIAL SCHEMATIC DESIGN ON SHEET TC504. ALL
CEILING MOUNTED DEVICES MUST BE CENTERED ON THE ASSOCIATED CEILING TILE.
REFER TO SPECIFICATION SECTION 285231 AND SHEET TC511 FOR CONNECTIVITY INFORMATIONEMERGENCY CALL STATION WALL MOUNTED
WALLS, CEILINGS, POLES (WITH
WALL MOUNT ADAPTER)
X W TELECOMMUNICATIONS OUTLET (TCO) FOR CLINICAL OR FMS SPECIFIC EQUIPMENT
DATA ONLY, WALL MOUNTED, 18" AFF UNLESS OTHERWISE NOTED
REFER TO SPECIFICATION SECTION 271500
REFER TO SPECIFICATION SECTION 271500
REFER TO SPECIFICATION SECTION 271500
REFER TO SPECIFICATION SECTION 271500
REFER TO SPECIFICATION SECTION 271500.
REFER TO DIV. 26 DRAWINGS FOR POKE-THRU OR FLOOR BOX LOCATIONS
REFER TO SPECIFICATION SECTION 271500
REFER TO SPECIFICATION SECTION 271500
REFER TO SPECIFICATION SECTION 271500. ALL CEILING MOUNTED DEVICES MUST BE CENTERED
ON THE ASSOCIATED CEILING TILE.
REFER TO SPECIFICATION SECTION 271500
REFER TO SPECIFICATION SECTION 271500
REFER TO SPECIFICATION SECTION 271500
REFER TO SPECIFICATION SECTION 271500
REFER TO SPECIFICATION SECTION 271500.
SEE DRAWINGS FOR SPECIFIC USE, CABLING AND SPECIAL ROUGH-IN REQUIREMENTS
REFER TO SPECIFICATION SECTION 271500.
REFER TO DIV. 26 DRAWINGS FOR POKE-THRU OR FLOOR BOX LOCATIONS
WALL MOUNTED RECESSED JUNCTION BOX WITH TWO (2) AIR-BLOWN FIBER TUBES
TERMINATED INSIDE , 18" AFF UNLESS OTHERWISE NOTED
REFER TO SPECIFICATION SECTION 271500
NZ
NZ
REEER TO SPECIFICATION SECTION 271500. PROVIDE STRUCTURED CABLING ONLY. WAP
ANTENNA SHALL BE PROVIDED BY THE ACTIVATION CONTRACTOR. ALL CEILING MOUNTED
DEVICES MUST BE CENTERED ON THE ASSOCIATED CEILING TILE.
REFER TO SPECIFICATION SECTION 275116 AND PARTIAL SCHEMATIC DESIGN ON SHEET TC505 AND TC513. ALL CEILING MOUNTED DEVICES MUST BE CENTERED ON THE ASSOCIATED CEILING
TILE.
NOTE: ALL CEILING MOUNTED CAMERAS MUST BE CENTERED…
This is the start of the file's text. The full file is on GovTribe.