This document includes a hazardous materials survey report and federal contract opportunity notice. The survey report documents an inspection of Facility 34032 located at Wright Patterson Air Force Base in Ohio, which is scheduled for demolition. Nine samples were collected and analyzed, with four testing positive for asbestos-containing materials. The opportunity notice is for Solicitation Number W912QR21R0006 to replace and construct a Type III hydrant fuel system at Wright Patterson Air Force Base. The project scope includes constructing new aboveground storage tanks, a pump house, piping, and demolition of underground storage tanks and an existing pumphouse. The solicitation will result in a firm-fixed-price contract with a magnitude between $10-25 million. Proposals are due for a best value evaluation of past performance, technical, and price factors. The contracting agency is the Department of the Army Corps of Engineers Louisville District.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DOWEN ENVIRONMENTAL
Environmental Consulting, Asbestos & Lead Testing, Evaluation and Air Sampling
2845 Evergreen Drive 937-408-0061 Springfield, Ohio 45504 DowenEnv@gmail.com
Hazardous Materials and NESHAP Survey for Demolition of FAC 34032 Date: 29 Dec 2020 D.E. Job #0345
On Dec 9th 2020, Mr. Gary Dowen, an Ohio EPA certified “Asbestos Hazard Evaluation Specialist” (Cert. #ES36150) was contacted by Mr. John Hearn of the US Army Corps of Engineers at Wright Patterson AFB to performed a comprehensive pre-demolition asbestos survey on Facility 34032 located on Wright Patterson AFB, West Ramp.
The purpose of this survey is to comply with the inspection requirements of the National Emission Standards for Hazardous Air Pollutants (NESHAP) as codified in 40 CFR 61.M for demolition of Load Bearing Structures. This comprehensive survey was performed to comply with the requirements as outlined in 40 CFR 61.145 and OAC 3745-20-02 for asbestos; 29 CFR 1926.62 for Lead Containing Materials; 40 CFR 761 for Toxic Materials; and 40 CFR 273 for potential RCRA Materials and Universal Waste; Additionally this survey is intended to comply with WPAFB Specification 01-02-20 or the most current environmental specifications to identify the presence of Hazardous, Toxics and Universal Waste Materials. . Asbestos sampling was performed IAW ASTM E2365-10. Two 1in holes were made into the CMU walls to investigate for the presence of Vermiculite ™ insulation in the outer walls
The survey was accomplished on 16 Dec 20 by Mr. Gary Dowen of “Dowen Environmental” and Mr.
Tom Wenk of “Elliot Environmental” who performed a visual inspection for, in addition to ACMs and LBPs, the following materials in all safely accessible areas:
1. Toxic, hazardous, and other regulated substances including Universal Waste that may contain mercury (switches, thermostats, lamps), PCBs (light ballasts, transformers) Lead Based Paint (LBP) and fluorescent Lamps;
2. Halons (fire suppression equipment), as well as spills and building components that contain these substances.
3. In addition, the survey included a visual inspection of exit signs and emergency lighting for mercury lamps and batteries.
4. A visual inspection for abandoned hazardous materials (e.g., gas cylinders, paints, spray cans, fuels, etc.) was also accomplished
This Inspection Report is submitted only for and is applicable only to the facility referenced in this report.
If you have any questions regarding this report please contact: Gary Dowen at 937 408-0061
Facility 34032 is located on Wright Patterson AFB’s West Ramp and is currently used to house jet fuel pumping equipment for flight line use. It is understood that this facility is scheduled for demolition.
W912QR21R0006-0002
mailto:DowenEnv@gmail.com
Hazardous Materials and NESHAP Survey for Demolition of FAC 34032 Date: 29 Dec 2020 D.E. Job #0345
Note: Fuel tanks, fuel lines (to include gaskets), and associated pumping equipment within the facility were not inspected as part of this survey. This survey was limited only to the structure and ancillary equipment as listed above. Electrical Switchgear located in the Control Room also was not tested due to electrical hazard.
Summation / Recommendations of Findings
Nine (9) samples of suspect asbestos containing materials (ACMs) were taken. These samples were sent to ALS laboratory located at 4388 Glendale-Milford Road Cincinnati Ohio 45242. ALS is an Ohio EPA Voluntary Action Program (VAP) and American Association for Laboratory Accreditation (A2LA) accredited laboratory providing environmental analytical services.
Of the nine (9) samples taken, four (4) tested positive for Asbestos Containing Materials and one (1) material tested for lead was reported with a low lead content.
1. Sample #351-3, Sample #351-4, Sample #351-5, and Sample #351-6
a. All sample results are >1 <3% ACM
b. This material is Cat. I, Non-Friable and does not need to be removed prior to demolition as long as it does not become friable during the demolition.
2. Sample #351-8 was a lead sample for the exterior paint. The lab reported the results as 2.9 mg/Kg or 2.9 ppm.
a. The RCRA limit for Lead is 5.0 ppm so this material is not regulated for disposal and does not need to be removed for demolition.
Additional Cat I non-friable suspect asbestos containing materials are identified but not tested and should be assumed ACM. These materials do not have to be removed prior to demolition if they are not rendered friable during the demolition:
1. Rubbery Expansion Joint around the interior perimeter of facility.
2. Expansion joints on conduits and vent lines
3. All asphaltic roofing materials
Hazardous Materials and NESHAP Survey for Demolition of FAC 34032 Date: 29 Dec 2020 D.E. Job #0345
In addition to the above identified materials, the following materials, components, and areas of the facility were visually inspected but not tested.
Component Location Quantity Recommendation Potential Waste Fire Extinguishers 1 -Control Rm
2- Pump Rm 3 Remove before demo Halon
Metal Halide Lamps & Ballasts
Pump Room 6 Remove before demolition
Halides** and PCBs*
Fluorescent Lamps and Ballasts
Control Rm 3 Fixtures 6 bulbs Remove before demolition
Mercury and PCBs*
Thermostat Pump Room West wall
1 Remove before demolition
Mercury
Flash Detector Pump Room East Wall above door
1 Remove before demolition
Mercury
Wall Mounted Elect Heaters
Pump Room 8 4 sets of 2
Remove and inspect for ACM before demo
Asbestos
*These components are suspected of containing Polychlorinated Biphenyl’s and must be individually inspected for PCBs IAW § 429.26 for proper disposal.
** These components are suspected of containing Metal Halides and must be individually inspected IAW § 431.321 for proper disposal
All above listed materials must be coordinated with 88 CEG/CEIE at 937 257-9009 for proper disposal before removal of materials or suspect components.
Additional Materials, components or materials were visually inspected but are not suspected of containing regulated waste:
1. Floor drain in pump room
a. Inspected, no suspect materials found
2. Emergency Exit Signs
a. Signs are painted above doorway and do not appear to contain batteries or other hazardous materials.
Attchment #1 Sample Record
Material WPAFB Fac 34032 DATE: 16 Dec 20
Smp # ID Code Description Sample Location Lab Description Lab # Results Est Qnty 351-1 FS1-1 Red Firebreak putty Numerious locations Interior/Exterier Red Homogeneous Rubbery 820-1A N/D 351-2 FS1-2 Red Firebreak putty 820-2A N/D 351-3 IWCI-1 Brn Window Caulking Window Caulking North Blk Homogeneous Rubbery 820-3A >1<3% 250LF 351-4 IWCI-2 Brn Window Caulking Window Caulking South 820-4A >1<3% 351-5 IDC1-1 Painted Grey Door Caulking North Gry/Yel Layered Compact 820-5A >1<3% 250LF 351-6 IDC1-2 Painted Grey Door Caulking West 820-6A >1<3% 351-7 EXTP-1 External Paint External Entire Facility Gry Homogeneous Flexible 820-7A N/D 351-8 EXTP-2 External Paint External (Note: Tested for Lead) 820-8A 2.9PPM
351-9 ECW1 External Conduit Wrap North/East outer wall Orn/Brn Layered Fibrous/Resinous 820-9A N/D
Hg
Hg
FAC 34032 Material Locations
W912QR21R0006-0002
Dowen Environmental Callout Metal Halide Lamps Typ. 6 Places
Dowen Environmental Oval
Dowen Environmental Oval
Dowen Environmental Oval
Dowen Environmental Oval
Dowen Environmental Oval
Dowen Environmental Oval
Dowen Environmental Rectangle
Dowen Environmental Rectangle
Dowen Environmental Rectangle
Dowen Environmental Rectangle
Dowen Environmental Polygon
Dowen Environmental Polygon
Dowen Environmental Callout Fluorescent Lamps and Ballasts Typ. 3 Places
Dowen Environmental Oval
Dowen Environmental Rectangle
Dowen Environmental Callout Smp #351-5 & -6
ID IDC1-1 & -2
>1 < 3% ACM
Door Caulking Typical Throughout
Dowen Environmental Callout Smp #351-3 & -4
ID IWC1-1 & -2
>1 < 3% ACM
Window Caulking Typical Throughout
Dowen Environmental Callout Floor Drain No Suspect Materials Found
Dowen Environmental Callout Assumed Mercury Thermostat / Switches
Dowen Environmental Line
Dowen Environmental Oval
Dowen Environmental Oval
Dowen Environmental Callout Vermiculite Sample Location - None Found
Dowen Environmental Callout Vermiculite Sample Location - None Found
Dowen Environmental Callout Fire Extinguisher Locations
Dowen Environmental Line
Dowen Environmental Callout Fire Extinguisher Location
Dowen Environmental Callout Electrical Heaters Typical Multiple Locations
Dowen Environmental Rectangle
Dowen Environmental Rectangle
Dowen Environmental Rectangle
Dowen Environmental Rectangle
Photo Sheets
Callout Smp # 351-9
ID IWC1
N/D for ACM Typical Throughout
Dowen Environmental Line
Dowen Environmental Line
Dowen Environmental Callout Smp # 351-1 & 2
ID FS1-1 & FS1-2
N/D for ACM Typical Throughout
Dowen Environmental Callout Smp # 351-8
ID EXPT-2
2.9 PPM Total Pb
Text Box Main Pump Room Looking East
Dowen Environmental Callout Assumed Mercury Containing Switch
Dowen Environmental Callout Fire Extinguisher
Dowen Environmental Text Box Main Pump Room Looking West
Dowen Environmental Callout Fire Extinguisher
Dowen Environmental Callout Assumed Mercury Containing Thermostat
Callout Elect Heaters Assumed ACM Insulators Internally
Dowen Environmental Callout Metal Halide Lamps 6 Places
Dowen Environmental Line
Dowen Environmental Line
Dowen Environmental Callout Floor Drain Visual Inspection Not Sampled No Suspect Materials Detected
Callout Assumed Mercury containing Thermostat
Dowen Environmental Callout Assumed Mercury Containing Flash Detector Switch
Dowen Environmental Text Box Main Pump Room West Wall
Dowen Environmental Text Box Main Pump Room East Wall Above Door
Callout Smp # 351-5 & 6
ID IDC1-1 & 1-2
>1 < 3% Typical Throughout
Dowen Environmental Callout Smp # 351-3 & 4
ID IWC1-1 & 1-2
>1 < 3% ACM
Typical Throughout
Text Box Control Room Looking South
Dowen Environmental Callout Fluorescent Lamp Fixtures 3 Places Assumed to contain PCB Ballasts
Dowen Environmental Line
Dowen Environmental Callout Fire Extinguisher
Dowen Environmental Text Box Control Room Looking North
Callout Electrical Switchgear Energized Not Sampled Assumed to Contain ACM Insulators
Dowen Environmental Callout Fire Extinguisher
Dowen Environmental Text Box Control Room Looking WNW
28-Dec-2020
Gary Dowen
Dear Gary, Re: WPAFB FAC 34032 Work Order: 20120820
2845 Evergreen Drive
Springfield, OH 45504
ALS Environmental received 9 samples on 18-Dec-2020 01:58 PM for the analyses presented in the following report.
Project Manager
Shawn Smythe
Shawn Smythe Electronically approved by: Danielle Strasinger
The analytical data provided relates directly to the samples received by ALS Environmental and for only the analyses requested.
QC sample results for this data met laboratory specifications. Any exceptions are noted in the Case Narrative, or noted with qualifiers in the report or QC batch information. Should this laboratory report need to be reproduced, it should be reproduced in full unless written approval has been obtained from ALS Laboratory Group. Samples will be disposed in 30 days unless storage arrangements are made.
The total number of pages in this report is 15.
If you have any questions regarding this report, please feel free to contact me.
Sincerely, ALS GROUP USA, CORP Part of the ALS Laboratory Group A Campbell Brothers Limited Company
Report of Laboratory Analysis
Date: 28-Dec-20ALS Environmental
Project: WPAFB FAC 34032
Client: Dowen Environmental
Work Order: 20120820 Work Order Sample Summary
Lab Samp ID Client Sample ID Collection DateTag Number Date ReceivedMatrix Hold
20120820-01 351-1 Bulk 12/16/2020 12/18/2020 13:58
20120820-02 351-2 Bulk 12/16/2020 12/18/2020 13:58
20120820-03 351-3 Bulk 12/16/2020 12/18/2020 13:58
20120820-04 351-4 Bulk 12/16/2020 12/18/2020 13:58
20120820-05 351-5 Bulk 12/16/2020 12/18/2020 13:58
20120820-06 351-6 Bulk 12/16/2020 12/18/2020 13:58
20120820-07 351-7 Bulk 12/16/2020 12/18/2020 13:58
20120820-08 351-8 Bulk 12/16/2020 12/18/2020 13:58
20120820-09 351-9 Bulk 12/16/2020 12/18/2020 13:58
Sample Summary Page 1 of 1
Date: 28-Dec-20ALS Environmental
Client: Dowen Environmental
Work Order: 20120820 Case Narrative
It is the responsibility of the client to notify the lab of any certification requirements in writing via the chain of custody as this may determine the preparation and analytical procedures employed.
Laboratory accreditation does not in any way constitute approval or endorsement by any accrediting body or agency of the federal government. Please contact ALS Cincinnati QA/QC Manager for accreditation identifications and certifications.
All sample collection is performed outside of ALS and is the sole responsibility of the client.
Sample condition acceptable upon receipt except where noted. Estimates of concentration are semi-quantitative and are made on an area basis. Results apply only to portions of samples analyzed. Samples disposed after 60 days.
All analytical data (results) and technical content (comments) related to the preparation and analysis of the samples stated herein is the responsibility of the analyst. Raw data is reviewed and validated by a qualified peer analyst and imported into the Laboratory Information Management System (LIMS) where it is formatted by the cover letter signatory charged with compiling and sending the final LIMS generated report to the client.
The reporting limit (RL) for asbestos in bulk materials is 1% and is a function of the quantity of sample analyzed, the nature of any matrix interferences, sample preparation, and fiber size and distribution. Results reported as ND indicate that no asbestos was detected. Results reported as Trace indicate that asbestos was detected at some level confidently determined to be <1% which is considered inconclusive according to New York ELAP.
ALS performs variety of PLM methods for asbestos in bulk building materials including EPA 600/R-93/116, NIOSH 9002, ELAP 198.1, and ELAP 198.6. In addition, we perform a modified uncertified version of EPA 600/R-04/004 for asbestos in vermiculite which reports asbestos as present or absent only, an in-house developed uncertified method ALS SOP ENV 004 for asbestos in soil, and asbestos in soil by ASTM D7521.
Regardless of the method requested, all samples are examined according to mandatory method protocol. Any optional method protocol are eliminated from the initial analysis but may be performed upon client request. These may include; insufficient sample volume rejection*, phase separation of layered or heterogeneous samples, ashing to remove organic interferences, acid dissolution to remove mineral carbonate interferences, point counting**, and analysis by transmission electron microscopy (TEM) is recommended to verify all ND PLM results.
All samples are examined by stereomicroscope for the determination of homogeneity, texture, friability, color, and extent of fibrous components. Non-asbestos materials such as foil, paper, metal, plastic, pebbles, or organic debris are ignored and a subsample of the remaining material homogenized by some means for examination by polarized light microscope (PLM).
Information obtained via both stereomicroscope and PLM are used in the final qualitative and quantitative analysis of fibrous components.
NOTE: Any visible building debris in soil samples such as pieces of drywall, roofing material, Case Narrative Page 1 of 2
Client: Dowen Environmental
Work Order: 20120820 Case Narrative insulation, concrete, etc., are not included in the soil analysis. If present, these are considered possible asbestos containing materials (ACM) and may be analyzed as separate samples upon client request.
*Sufficient sample volume is material dependent. For samples such as floor tiles, roofing felts, sheet insulation, etc., three to four square inches of the layered material is preferred. For materials such as ceiling tiles, loose fill insulation, pipe insulation, etc., one cubic inch (~15cc) is preferred. For samples of thin coating materials such as paints, mastics, spray plasters, etc., a smaller sample size may be suitable. For vermiculite analysis, a one gallon ziploc bag full of dry, loose material is acceptable. For ENV 004 soil samples, a 4oz jar is recommended.
The ASTM D7521 Soil method requires a minimum of 8oz and a maximum of 16oz of homogeneous soil.
**PLM samples at or near the 1% detection limit may be analyzed by the 400 point count analysis which refers to method EPA 600/M4/82/020, or AHERA method EPA 40 CFR Part 763, Sub. E, App. E as these are synonymous
Case Narrative Page 2 of 2
Client: Dowen Environmental Work Order: 20120820
ALS Environmental Date: 28-Dec-20
Client Sample ID: 351-8
Lab ID: 20120820-08A Collection Date: 12/16/2020
Matrix: BULK
Analyses Result Qual Units Date Analyzed Report Limit
Dilution Factor
LEAD PAINT BY ICP SW6010B Analyst: AZPrep: SW3050B 12/22/20 14:30
Lead 12/22/2020 03:47 PM2.9 mg/Kg 116
AR Page 1 of 1
Note:
ALS Environmental Date: 28-Dec-20
Client Sample ID: 351-1
Lab ID: 20120820-01A Collection Date: 12/16/2020
Matrix: BULK
Analyses Result Units Analytical Results
E600/R-93/116 Analyst: MRSPrep Date: 12/21/2020Macroscopic Examination
12/28/2020Date AnalyzedAsbestos by PLM
Color Red
Description Material
Homogeneity Homogeneous
Texture Rubbery
E600/R-93/116Other Materials
Cellulose %>1<=3
Fiberglass %>1<=3
Non-fibrous %>40<=50
Other fibers %ND
Resin/binder %>40<=50
E600/R-93/116Asbestiform Minerals
Amosite 0.10%ND
Anthophyllite 0.10%ND
Chrysotile 0.10%ND
Crocidolite 0.10%ND
Tremolite - actinolite 0.10%ND
Total asbestos 0.10%ND
AR Page 1 of 8
ALS Environmental Date: 28-Dec-20
Client Sample ID: 351-2
Lab ID: 20120820-02A Collection Date: 12/16/2020
Matrix: BULK
Analyses Result Units Analytical Results
E600/R-93/116 Analyst: MRSPrep Date: 12/21/2020Macroscopic Examination
12/28/2020Date AnalyzedAsbestos by PLM
Color Red
Description Material
Homogeneity Homogeneous
Texture Rubbery
E600/R-93/116Other Materials
Cellulose %ND
Fiberglass %>1<=3
Non-fibrous %>40<=50
Other fibers %ND
Resin/binder %>40<=50
E600/R-93/116Asbestiform Minerals
Amosite 0.10%ND
Anthophyllite 0.10%ND
Chrysotile 0.10%ND
Crocidolite 0.10%ND
Tremolite - actinolite 0.10%ND
Total asbestos 0.10%ND
AR Page 2 of 8
ALS Environmental Date: 28-Dec-20
Client Sample ID: 351-3
Lab ID: 20120820-03A Collection Date: 12/16/2020
Matrix: BULK
Analyses Result Units Analytical Results
E600/R-93/116 Analyst: MRSPrep Date: 12/21/2020Macroscopic Examination
12/28/2020Date AnalyzedAsbestos by PLM
Color Black
Description Material
Homogeneity Homogeneous
Texture Rubbery
E600/R-93/116Other Materials
Cellulose %ND
Fiberglass %ND
Non-fibrous %>40<=50
Other fibers %ND
Resin/binder %>40<=50
E600/R-93/116Asbestiform Minerals
Amosite 0.10%ND
Anthophyllite 0.10%ND
Chrysotile 0.10%>1<=3
Crocidolite 0.10%ND
Tremolite - actinolite 0.10%ND
Total asbestos 0.10%>1<=3
AR Page 3 of 8
ALS Environmental Date: 28-Dec-20
Client Sample ID: 351-4
Lab ID: 20120820-04A Collection Date: 12/16/2020
Matrix: BULK
Analyses Result Units Analytical Results
E600/R-93/116 Analyst: MRSPrep Date: 12/21/2020Macroscopic Examination
12/28/2020Date AnalyzedAsbestos by PLM
Color Black
Description Material
Homogeneity Homogeneous
Texture Rubbery
E600/R-93/116Other Materials
Cellulose %ND
Fiberglass %ND
Non-fibrous %>40<=50
Other fibers %ND
Resin/binder %>40<=50
E600/R-93/116Asbestiform Minerals
Amosite 0.10%ND
Anthophyllite 0.10%ND
Chrysotile 0.10%>1<=3
Crocidolite 0.10%ND
Tremolite - actinolite 0.10%ND
Total asbestos 0.10%>1<=3
AR Page 4 of 8
ALS Environmental Date: 28-Dec-20
Client Sample ID: 351-5
Lab ID: 20120820-05A Collection Date: 12/16/2020
Matrix: BULK
Analyses Result Units Analytical Results
E600/R-93/116 Analyst: MRSPrep Date: 12/21/2020Macroscopic Examination
12/28/2020Date AnalyzedAsbestos by PLM
Color Grey/Yellow
Description Material
Homogeneity Layered/Inseparable
Texture Compact
E600/R-93/116Other Materials
Cellulose %ND
Fiberglass %ND
Non-fibrous %>70<=80
Other fibers %ND
Resin/binder %>10<=20
E600/R-93/116Asbestiform Minerals
Amosite 0.10%ND
Anthophyllite 0.10%ND
Chrysotile 0.10%>1<=3
Crocidolite 0.10%ND
Tremolite - actinolite 0.10%ND
Total asbestos 0.10%>1<=3
AR Page 5 of 8
ALS Environmental Date: 28-Dec-20
Client Sample ID: 351-6
Lab ID: 20120820-06A Collection Date: 12/16/2020
Matrix: BULK
Analyses Result Units Analytical Results
E600/R-93/116 Analyst: MRSPrep Date: 12/21/2020Macroscopic Examination
12/28/2020Date AnalyzedAsbestos by PLM
Color Grey/Yellow
Description Material
Homogeneity Layered/Inseparable
Texture Compact
E600/R-93/116Other Materials
Cellulose %ND
Fiberglass %ND
Non-fibrous %>70<=80
Other fibers %ND
Resin/binder %>10<=20
E600/R-93/116Asbestiform Minerals
Amosite 0.10%ND
Anthophyllite 0.10%ND
Chrysotile 0.10%>1<=3
Crocidolite 0.10%ND
Tremolite - actinolite 0.10%ND
Total asbestos 0.10%>1<=3
AR Page 6 of 8
ALS Environmental Date: 28-Dec-20
Client Sample ID: 351-7
Lab ID: 20120820-07A Collection Date: 12/16/2020
Matrix: BULK
Analyses Result Units Analytical Results
E600/R-93/116 Analyst: MRSPrep Date: 12/21/2020Macroscopic Examination
12/28/2020Date AnalyzedAsbestos by PLM
Color Grey
Description Material
Homogeneity Homogeneous
Texture Flexible
E600/R-93/116Other Materials
Cellulose %ND
Fiberglass %ND
Non-fibrous %>50<=60
Other fibers %ND
Resin/binder %>30<=40
E600/R-93/116Asbestiform Minerals
Amosite 0.10%ND
Anthophyllite 0.10%ND
Chrysotile 0.10%ND
Crocidolite 0.10%ND
Tremolite - actinolite 0.10%ND
Total asbestos 0.10%ND
AR Page 7 of 8
ALS Environmental Date: 28-Dec-20
Client Sample ID: 351-9
Lab ID: 20120820-09A Collection Date: 12/16/2020
Matrix: BULK
Analyses Result Units Analytical Results
E600/R-93/116 Analyst: MRSPrep Date: 12/21/2020Macroscopic Examination
12/28/2020Date AnalyzedAsbestos by PLM
Color Orange/Brown
Description Material
Homogeneity Layered/Inseparable
Texture Fibrous/Resinous
E600/R-93/116Other Materials
Cellulose %ND
Fiberglass %ND
Non-fibrous %>20<=30
Other fibers %>5<=10
Resin/binder %>50<=60
E600/R-93/116Asbestiform Minerals
Amosite 0.10%ND
Anthophyllite 0.10%ND
Chrysotile 0.10%ND
Crocidolite 0.10%ND
Tremolite - actinolite 0.10%ND
Total asbestos 0.10%ND
AR Page 8 of 8
ALS Environmental Date: 28-Dec-20
QUALIFIERS,
ACRONYMS, UNITS
Project: WPAFB FAC 34032
Client: Dowen Environmental
WorkOrder: 20120820
Units Reported Description
Qualifier Description
Acronym Description mg/Kg
Value exceeds Regulatory Limit*
Not accrediteda
Analyte detected in the associated Method Blank above the Reporting LimitB
Value above quantitation rangeE
Analyzed outside of Holding TimeH
Analyte detected below quantitation limitJ
Not offered for accreditationn
Not Detected at the Reporting LimitND
Sample amount is > 4 times amount spikedO
Dual Column results percent difference > 40%P
RPD above laboratory control limitR
Spike Recovery outside laboratory control limitsS
Analyzed but not detected above the MDLU
Method DuplicateDUP
EPA MethodE
Laboratory Control SampleLCS
Laboratory Control Sample DuplicateLCSD
Method BlankMBLK
Method Detection LimitMDL
Method Quantitation LimitMQL
Matrix SpikeMS
Matrix Spike DuplicateMSD
Post Digestion SpikePDS
Practical Quantitaion LimitPQL
Sample Detection LimitSDL
SW-846 MethodSW
QF Page 1 of 1
ALS Environmental
Sample Receipt Checklist
Client Name: DOWEN-SPRINGFIELD
Work Order: 20120820
Date/Time Received: 18-Dec-20 13:58
Received by: SNH
Checklist completed by eSignature Date
Reviewed by:
DateeSignature
Matrices:
Carrier name: FedEx
Shipping container/cooler in good condition? Yes No Not Present
Custody seals intact on shipping container/cooler? Yes No Not Present
Custody seals intact on sample bottles? Yes No Not Present
Chain of custody present? Yes No
Chain of custody signed when relinquished and received? Yes No
Chain of custody agrees with sample labels? Yes No
Samples in proper container/bottle? Yes No
Sample containers intact? Yes No
Sufficient sample volume for indicated test? Yes No
All samples received within holding time? Yes No
Container/Temp Blank temperature in compliance? Yes No
Yes No No VOA vials submittedWater - VOA vials have zero headspace?
Water - pH acceptable upon receipt? Yes No N/A
Temperature(s)/Thermometer(s):
Login Notes:
Cooler(s)/Kit(s):
18-Dec-20 21-Dec-20 Danielle Strasinger Shawn Smythe pH adjusted? Yes No N/A pH adjusted by:
Date/Time sample(s) sent to storage:
Sample(s) received on ice? Yes No
CorrectiveAction:
Comments:
Client Contacted: Date Contacted: Person Contacted:
Contacted By: Regarding:
SRC Page 1 of 1