This document contains a federal contract solicitation and technical specifications for a waterproofing membrane. The solicitation requests proposals for construction of a Special Operations Forces Assessment and Selection Training Complex at Camp Mackall in North Carolina. Work includes new training facilities, storage buildings, locker rooms, showers, guard houses, security gates, under vehicle surveillance systems, communications and utility infrastructure, and a physical training obstacle course. Technical specifications provide requirements for an elastomeric sheet waterproofing system using a composite self-adhering EPDM membrane with a minimum thickness of 60 mils. Installation instructions are included for surface preparation, priming, membrane application and seaming, flashing of drains and projections, protection during construction, and acceptance requirements. The Army Corps of Engineers is the contracting agency.
View the file
Other files for this federal contract opportunity
Show all 50
SOF Assessment and Selection Training Complex has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SOF ASSESSMENT AND SELECTION TRAINING COMPLEX
CAMP MACKALL, NC
PN 86021 FY20
NORTH CAROLINA
SECTION 07 13 53 Page 1
(ADDED BY AMENDMENT)
SECTION TABLE OF CONTENTS
DIVISION 07 - THERMAL AND MOISTURE PROTECTION
SECTION 07 13 53*
ELASTOMERIC SHEET WATERPROOFING
02/16
PART 1 GENERAL
1.1 REFERENCES
1.2 SUBMITTALS
1.3 MANUFACTURER'S DETAILS
1.4 DELIVERY, STORAGE, HANDLING, IDENTIFICATION
PART 2 PRODUCTS
2.1 MATERIALS
2.2 EPDM, SELF-ADHERING MEMBRANE SHEETING
2.2.1 Composite, Self-Adhering Sheeting Performance Requirements
2.2.2 Primers
2.2.3 Mastics
PART 3 EXECUTION
3.1 VERIFICATION OF CONDITIONS
3.2 SURFACE PREPARATION
3.3 APPLICATION
3.3.1 General Installation Requirements
3.3.1.1 Self-Adhering Membrane
3.3.1.2 Protection
3.4 COMPOSITE, SELF-ADHERING MEMBRANE
3.5 PROTECTIVE COVERING
-- End of Section Table of Contents --
PN 86021 FY20
NORTH CAROLINA
SECTION 07 13 53 Page 2
(ADDED BY AMENDMENT)
THIS PAGE INTENTIONALLY LEFT BLANK
PN 86021 FY20
NORTH CAROLINA
SECTION 07 13 53 Page 3
(ADDED BY AMENDMENT)
PART 1 GENERAL
1.1 REFERENCES
SECTION 07 13 53
ELASTOMERIC SHEET WATERPROOFING
02/16
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
ASTM INTERNATIONAL (ASTM)
ASTM D146/D146M (2004; E 2012; R 2012) Sampling and
Testing Bitumen-Saturated Felts and Woven
Fabrics for Roofing and Waterproofing
ASTM D1876 (2008; R 2015; E 2015) Standard Test
Method for Peel Resistance of Adhesives
(T-Peel Test)
ASTM D41/D41M (2011) Asphalt Primer Used in Roofing, Dampproofing, and Waterproofing
ASTM D412 (2006a; R 2013) Standard Test Methods for
Vulcanized Rubber and Thermoplastic
Elastomers - Tension
ASTM D5385/D5385M (1993; R 2014; E 2014) Standard Test
Method for Hydrostatic Pressure Resistance of Waterproofing Membranes
ASTM D570 (1998; E 2010; R 2010) Standard Test
Method for Water Absorption of Plastics
ASTM D903 (1998; R 2010) Peel or Stripping Strength of Adhesive Bonds
ASTM E154/E154M (2008a; R 2013; E 2013) Water Vapor
Retarders Used in Contact with Earth Under
Concrete Slabs, on Walls, or as Ground
Cover
ASTM E96/E96M (2014) Standard Test Methods for Water
Vapor Transmission of Materials
1.2 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for information only.
Submittals with an "S" are for inclusion in the Sustainability Notebook, in conformance with Section 01 33 29.00 37 SUSTAINABILITY REPORTING.
Submit the following in accordance with Section 01 33 00.00 37 SUBMITTAL
PROCEDURES:
PN 86021 FY20
NORTH CAROLINA
SECTION 07 13 53 Page 4
(ADDED BY AMENDMENT)
SD-03 Product Data
Manufacturer's Standard Details
Elastomeric Waterproofing Sheet Material
1.3 MANUFACTURER'S DETAILS
Submit manufacturer's standard details indicating methods of attachment and spacing, transition and termination details, and installation details.
1.4 DELIVERY, STORAGE, HANDLING, IDENTIFICATION
Deliver and store materials in accordance with manufacturer's printed instructions, out of the weather, in manufacturer's original packaging with brand name and product identification clearly marked. Keep materials wrapped and separated from off-gassing materials (such as drying paints and adhesives). Do not use materials that have visible moisture or biological growth. Do not permit unidentified materials in the work area or in the project.
PART 2 PRODUCTS
2.1 MATERIALS
Provide one of the types of elastomeric waterproofing sheet material and related primers, adhesives, and mastics as specified herein. Ensure compatibility of waterproofing materials with each other, and with materials on which they are applied. Provide materials that comply with applicable requirements cited below when tested in accordance with the referenced ASTM publications.
2.2 EPDM, SELF-ADHERING MEMBRANE SHEETING
Cold applied composite sheet consisting of rubberized asphalt and cross laminated, high density polyethylene film. Not less than 60 mils minimum thickness is required.
2.2.1 Composite, Self-Adhering Sheeting Performance Requirements
a. Tensile Strength ASTM D412, Die C: 250 psi minimum.
b. Ultimate Elongation, ASTM D412, Die C: 200 percent minimum.
c. Water Vapor Transmission, ASTM E96/E96M 80 degrees F Permeance, Procedure B: 0.1 perm maximum.
d. Pliability degrees, ASTM D146/D146M: (180 degrees Bend Over 1 Inch
Mandrel): No cracks at minus minus 25 degrees F.
e. Puncture Resistance, ASTM E154/E154M REV A: 40 lb minimum.
f. Lap Adhesion at Minimum Application Temperature, ASTM D1876 Modified, 5 lbs/in..
g. Peel Strength, ASTM D903: Modified 9 lbs/in.
h. Resistance to Hydrostatic Head, ASTM D5385/D5385M: 231 ft of water.
PN 86021 FY20
NORTH CAROLINA
SECTION 07 13 53 Page 5
(ADDED BY AMENDMENT)
i. Water Absorption, ASTM D570; 0.1 percent maximum.
2.2.2 Primers
Asphalt composition, ASTM D41/D41M, or synthetic polymer in solvent as recommended by the membrane manufacturer.
2.2.3 Mastics
Polymer modified asphalt in suitable solvent of trowel grade consistency and as recommended by the membrane manufacturer.
PART 3 EXECUTION
3.1 VERIFICATION OF CONDITIONS
Before starting the work, verify latrine floor slab surfaces that must be waterproofed are in satisfactory condition. Notify the Contracting
Officer of defects or conditions anticipated to prevent a satisfactory application. Do not start application until defects and conditions have been corrected.
3.2 SURFACE PREPARATION
Ensure surfaces to receive treatment are clean, dry, smooth, and free from deleterious materials and projections. Sweep surfaces to receive covering before applying waterproofing to remove dust and foreign matter. Cure concrete by a method compatible with the waterproofing system.
3.3 APPLICATION
3.3.1 General Installation Requirements
Provide sheet waterproofing in accordance with manufacturer's printed installation instructions. Ensure the floor slab surface to receive membrane is clean, smooth and dry without surface3 inches, max. (to avoid exposure above sloped topping slab irregularities; correct deficiencies prior to installation. Carry waterproofing of horizontal surfaces up abutting vertical surfaces and adhere solid to the substrate. Avoid wrinkles and buckles in applying membrane and joint reinforcement.
3.3.1.1 Self-Adhering Membrane
Apply composite, self-adhering membrane on surfaces primed at a uniform coverage rate in accordance with membrane manufacturer's printed instructions. Remove release sheet and apply with tacky surface in contact with dried primer.
3.3.1.2 Protection
Protect membrane over horizontal surfaces from traffic during installation. Use only equipment with rubber tires. Provide walkway protection where heavy traffic from other trades is expected. Do not store material on membrane.
3.4 COMPOSITE, SELF-ADHERING MEMBRANE
Lap sheets at edges and ends a minimum of 2-1/2 inches over the preceding sheet. Provide all side laps a minimum 2-1/2 inches and end laps 5 inches.
PN 86021 FY20
NORTH CAROLINA
SECTION 07 13 53 Page 6
(ADDED BY AMENDMENT)
Provide self-adhesive, mastic laps in accordance with manufacturer's recommendation. Roll or firmly press to adhere membrane to substrate.
Cover corners and joints with two layers of reinforcement by first applying a 12 inch width of membrane centered along the axis. Flash drains and projections with a second ply of membrane for a distance of 6 inches from the drain or projection. Finish exposed, terminated edges of membrane on horizontal or vertical surfaces with a toweled bead of mastic. Apply mastic around edges of membrane, and drains and projections. Apply mastic at end of each work day.
3.5 PROTECTIVE COVERING
After installation has been inspected and approved by the Contracting
Officer, apply a protective covering to the membrane waterproofing prior toinstallation of sloped topping slab.
-- End of Section --