EMERGENCY LIGHTING FIXTURE WITH BATTERIES, LED LAMP AND EXIT SIGN
PLAFONIERA DI EMERGENZA CON BATTERIE, LAMPADA LED E SEGNALE DI USCITA
SINGLE POLE LIGHTING SWITCH
INTERRUTTORE UNIPOLARE COMANDO LUCE
NEWEXISTING
NUOVOESISTENTE
SENSOR MOTION SWITCH
INTERRUTTORE CON SENSORE DI MOVIMENTO
CIRCUIT BREAKER WITH THERMAL AND MAGNETIC RELAY
INTERRUTTORE AUTOMATICO MAGNETOTERMICO
CIRCUIT BREAKER WITH THERMAL, MAGNETIC AND GROUND FAULT RELAY
INTERRUTTORE AUTOMATICO MAGNETOTERMICO DIFFERENZIALE
SWITCH DISCONNECTOR
INTERRUTTORE-SEZIONATORE
DISTRIBUTION AND GENERAL SYMBOLS
DISTRIBUZIONE E SIMBOLI GENERALI
NEWEXISTING
NUOVOESISTENTE
LIGHTING SYSTEM SYMBOLS
SIMBOLI IMPIANTI ILLUMINAZIONE
SINGLE POLE LIGHTING 2 WAY SWITCH
DEVIATORE UNIPOLARE COMANDO LUCE
U.S.A. STANDARD SINGLE OUTLET 110V
PRESA SINGOLA STANDARD U.S.A. 110V
UNEL UNIVERSAL OUTLET 2P+G 10/16A 230V
PRESA UNEL 2P+T UNIVERSALE 10/16A 230V
NEWEXISTING
NUOVOESISTENTE
POWER SYSTEM SYMBOLS
SIMBOLI IMPIANTI F.M.
NEWEXISTING
NUOVOESISTENTE
ITALIAN STANDARD OUTLET 2P+G 230V (10/16A, 10A, 16A, AS SHOWN)
PRESA STANDARD ITALIANO 2P+T 230V (10/16A, 10A, 16A, COME INDICATO)
PRESA CEE 2P+T CON INTERR. DI BLOCCO E FUSIBILI
2P+G CEE OUTLET WITH LOCK SWITCH AND FUSES
NEWEXISTING
NUOVOESISTENTE
WIRE DIAGRAMS SIMBOLS
SIMBOLI SCHEMI ELETTRICI
DOUBLE POLE LIGHTING SWITCH
INTERRUTTORE BIPOLARE COMANDO LUCE
PULL CORD PUSHBUTTON FOR ASSISTANCE REQUEST
PULSANTE A TIRANTE PER RICHIESTA ASSISTENZA
LIGHT AND BUZZER REPORTING ASSISTANCE REQUEST OF RESTROOMS
LAMPADA E SUONERIA DI SEGNALAZIONE RICHIESTA ASSISTENZA SERVIZI IGIENIGI
LED LIGHTING FIXTURE 600x600 MM RECESSED IN FALSE CEILING (3x=25W , 4x=33W)
PLAFONIERA LED 600x600 MM INCASSATA NEL CONTROSOFFITTO (3x=25W , 4x=33W)
EMERGENCY LIGHTING FIXTURE WITH BATTERIES AND LED LAMP
PLAFONIERA DI EMERGENZA CON BATTERIE E LAMPADA LED
NEWEXISTING
NUOVOESISTENTE
GROUNDING SYSTEM SIMBOLS
SIMBOLI IMPIANTO DI TERRA
GROUNDING SYSTEM BUSBAR
COLLETTORE IMPIANTO DI MESSA A TERRA
GROUND PIT
POZZETTO CON DISPERSORE DI TERRA
FLUORESCENT WATER PROOF LIGHTING FIXTURE WITH 2 LAMPS, CEILING MOUNTED
PLAFONIERA STAGNA FLUORESCENTE A 2 TUBI MONTATA A SOFFITTO
24W LED SINGLE LAMP LIGHTING FIXTURE , IP65, POLYCARBONATE HOUSING
PLAFONIERA LED MONOLAMPADA 24W, IP65, CORPO IN POLICARBONATO
FLUORESCENT WATER PROOF LIGHTING FIXTURE WITH 1 LAMP, WALL MOUNTED
PLAFONIERA STAGNA FLUORESCENTE A 1 TUBO MONTATA A PARETE
FLUORESCENT WATER PROOF LIGHTING FIXTURE WITH 2 LAMPS, WALL MOUNTED
PLAFONIERA STAGNA FLUORESCENTE A 2 TUBI MONTATA A PARETE
UNEL UNIVERSAL OUTLET 2P+G 10/16A 230V WITH GFI
PRESA UNEL 2P+T UNIVERSALE 10/16A 230V CON INTERRUTTORE DIFFERENZIALE
CONNESSIONE ELETTRICA POMPA-MOTORE-ASPIRATORE-FANCOIL:
- EX = ESTRATTORE
- FC = FANCOIL
- M = MOTORIZZAZIONE GENERICA
- P = POMPA GENERICA
- H = AEROTERMO
PUMP-MOTOR-EXHAUST FAN-FANCOIL ELECTRICAL CONNECTION:
- EX = EXHAUST FAN
- FC = FANCOIL
- M = GENERIC MOTORIZATION
- P = GENERIC PUMP
- H = HEATER
HOUSING BOX WITH CIRCUIT BREAKER FOR MOTOR PROTECTION
SALVAMOTORE IN SCATOLA DI CONTENIMENTO
ELECTRICAL CONNECTION OF A/C INTERNAL UNIT
PUNTO ALIMENTAZIONE UNITA' INTERNA DI CONDIZIONAMENTO A/C
EMERGENCY PUSHBUTTON TO SHUTDOWN ENERGY
PULSANTE EMERGENZA PER SGANCIO ENERGIA
ES
PULSANTE UNIPOLARE COMANDO LUCE
CONTROL LIGHTING BUTTON WITH SINGLE POLE
PLAFONIERA FLUORESCENTE A 2 TUBI, SCHERMO LAMELLARE, MONTATA A SOFFITTO
FLUORESCENT LIGHTING FIXTURE WITH 2 LAMPS, LAMELLAR SCREEN, CEILING MOUNTED
INTERRUTTORE CON SENSORE DI MOVIMENTO 360°, INSTALLAZIONE A SOFFITTO
SENSOR MOTION SWITCH 360°, CEILING MOUNTING
CORPO ILLUMINANTE A SOFFITTO
CEILING MOUNTED LIGHTING FIXTURE
CORPO ILLUMINANTE A PARETE
WALL MOUNTED LIGHTING FIXTURE
PROIETTORE ESTERNO INSTALLATO A PARETE
WALL MOUNTED EXTERNAL PROJECTOR
CONNESSIONE ELETTRICA DI APPARECCHIATURA GENERICA
ELECTRICAL CONNECTION OF GENERIC EQUIPMENT
CONNESSIONE ELETTRICA SCALDA-ACQUA
ELECTRICAL CONNECTION OF BOILER
CENTRALINA CON COMANDO MOTORIZZAZIONE SERRANDA
CONTROL PANEL FOR ELECTRIC DOOR
CEILING MOUNTED FAN
VENTILATORE A SOFFITTO
SPEED DRIVE FOR CEILING MOUNTED FAN
VARIATORE VELOCITA' PER VENTILATORE A SOFFITTO
TERMOSTATO AMBIENTE
THERMOSTAT
PRESA CEE 2P+T CON INTERR. DI BLOCCO E FUSIBILI - 110V
2P+G CEE OUTLET WITH LOCK SWITCH AND FUSES - 110V
PLAFONIERA FLUORESCENTE A 3 TUBI, SCHERMO LAMELLARE, MONTATA A SOFFITTO
FLUORESCENT LIGHTING FIXTURE WITH 3 LAMPS, LAMELLAR SCREEN, CEILING MOUNTED
ELECTRICAL SYMBOLS LEGEND
LEGENDA SIMBOLI ELETTRICI
ELECTRICAL CONNECTION OF A/C EXTERNAL UNIT
PUNTO ALIMENTAZIONE UNITA' ESTERNA DI CONDIZIONAMENTO A/C
E
FARETTO LED AD INCASSO
RECESSED LED DOWNLIGHT
GF
PRESA CEE 2P+T CON INTERR. DI BLOCCO (16A)
2P+G CEE OUTLET WITH LOCK SWITCH (16A)
PRESA CEE 3P+T CON INTERR. DI BLOCCO ( 16A 32A )
3P+G CEE OUTLET WITH LOCK SWITCH ( 16A 32A )
PRESA CEE 3P+N+T CON INTERR. DI BLOCCO (16A)
3P+N+G CEE OUTLET WITH LOCK SWITCH (16A)
HATCHS LEGEND
LEGENDA RETINATURE
REMOVE EXISTING ELECTRICAL SYSTEMS (LIGHTING OR POWER) PLACED INSIDE INSIDE
THE INDICATED AREA.
RIMUOVERE GLI IMPIANTI ELETTRICI ESISTENTI (ILLUMINAZIONE O F.M.)POSTI
ALL'INTERNO DELLA ZONA INDICATA .
COMPONENT/EQUIPMENT TO REMOVE
ELEMENTO/APPARECCHIATURA DA RIMUOVERE.
IF THIS DRAWING IS LESS THAN 841 X 594 mm IT IS A REDUCED SIZE DRAWING
SE QUESTO DISEGNO È PIÙ PICCOLO DI 841 X 594 mm È UN DISEGNO A DIMENSIONI RIDOTTE
NOTE: / NOTA:
APPARECCHIO LED A PARETE
WALL MOUNTED LED LIGHTING FIXTURE
NOTA: PER DETTAGLI E SPECIFICHE TECNICHE DEI NUOVI CORPI ILLUMINANTE, VEDERE LA TAVOLA EL502.
NOTE: FOR DETAILS AND TECHNICAL SPECIFICATION OF THE NEW LIGHTING FIXTURES, SEE DRAWING EL502.
PVC RIGID CONDUIT OR PVC FLEXIBLE SHEATH, ABOVE FALSE CEILING
TUBAZIONE RIGIDA IN PVC O GUAINA FLESSIBILE IN PVC SOPRA CONTROSOFFITTO
GALVANIZED STEEL CONDUIT WITH EXPOSED MOUNTING
TUBAZIONE ACCIAIO ZINCATO CON POSA ESPOSTA
STEEL CABLE TRAY WITH COVER
CANALE PORTACAVI IN ACCIAIO ZINCATO CON COPERCHIO
GALVANIZED STEEL WIRE CABLE TRAY WITH COVER
PASSERELLA A FILO IN ACCIAIO ZINCATO CON COPERCHIO
DISTRIBUTION PANEL
QUADRO ELETTRICO DISTRIBUZIONE
JUNCTION BOX
SCATOLA DI DERIVAZIONE
CHANGE LEVEL OR LOWERING/UPRIGHT OF CABLE TRAY, RACEWAY OR CONDUIT
VARIAZIONE DI PIANO O CALATA/MONTANTE DI CANALE, CANALETTA O TUBAZIONE
DISCONNECTOR SWITCH
INTERRUTTORE SEZIONATORE
J
ELECTRICAL SYSTEMS MANHOLE/HANDHOLE
POZZETTO IMPIANTI ELETTRICI
ELECTRICAL MV LINE PLACED INSIDE UNDERGROUND DUCTBANK
LINEA ELETTRICA MT POSATA IN CAVIDOTTO INTERRATO
ELECTRICAL LV LINE PLACED INSIDE UNDERGROUND DUCTBANK
LINEA ELETTRICA BT POSATA IN CAVIDOTTO INTERRATO
ES
Ex
ESx
ELECTRICAL SYSTEMS HANDHOLE WITH GROUNDING ROD
POZZETTO IMPIANTI ELETTRICI CON DISPERSORE DI TERRA
Cpp
RXB
IMPIANTO REGOLAZIONE: REGOLATORE AMBIENTE INSTALLATO IN APPOSITA SCATOLA
SOPRA IL CONTROSOFFITTO DEL LOCALE
CONTROL SYSTEM: ROOM REGULATOR INSTALLED INSIDE BOX PLACED ABOVE FALSE
CEILING OF THE ROOM
UNITA' LOCALE CON SENSORE DI TEMPERATURA, POTENZIOMETRO PER REGOLAZIONE
SETPOINT DI TEMPERATURA ±3K, REGOLAZIONE MANUALE VELOCITA' FAN-COIL.
INSTALLAZIONE A PARETE.
ROOM UNIT WITH TEMPERATURE SENSOR, POTENZIOMETER FOR ±3K SETPOINT
CONTROL, MANUAL FAN-COIL SPEED CONTROL. WALL MOUNTING.
IMPIANTO REGOLAZIONE: UNITA' LOCALE CON SENSORE DI TEMPERATURA INSTALLATA
A PARETE
CONTROL SYSTEM: ROOM UNIT WITH TEMPERATURE SENSOR, WALL MOUNTING
Cpp1
36W LED DOUBLE LAMP LIGHTING FIXTURE , IP65, POLYCARBONATE HOUSING
PLAFONIERA LED BILAMPADA 36W, IP65, CORPO IN POLICARBONATO
42W LED DOUBLE LAMP LIGHTING FIXTURE , IP65, STEEL DEEP HOUSING
PLAFONIERA LED BILAMPADA 42W, IP65, CORPO IN ACCIAIO IMBUTITO
FLUORESCENT LIGHTING FIXTURE 600x600 MM RECESSED IN FALSE CEILING
PLAFONIERA FLUORESCENTE 600x600 MM INCASSATA NEL CONTROSOFFITTO
LAMPADA PORTATILE 24V CON AVVOLGICAVO E TRASFORMATORE 230/24 V
24V PORTABLE LAMP WITH REEL AND 230/24 V TRANSFORMER
VEHICLES EXHAUST GASES EXTRACTOR WITH ELECTRIC HOSE REEL
ESTRATTORE GAS DI SCARICO VEICOLI CON AVVOLGITUBO ELETTRICO
CONTROL OF VEHICLES EXHAUST GASES EXTRACTOR WITH ELECTRIC HOSE REEL
COMANDO ESTRATTORE GAS DI SCARICO VEICOLI CON AVVOLGITUBO ELETTRICO
M EX
INTERR. RIVELAT. DI MOVIMENTO AD ALTA FREQUENZA (TIPO "HF"),INSTAL. A SOFFITTO
MOTION DETECTOR SWITCH WITH HIGH FREQUENCY ("HF" TYPE), CEILING MOUNTING
CABLE TRAYS: RESTORE FIRE PARTITION
CANALI PORTACAVI: RIPRISTINO COMPARTIMENTAZIONE ANTINCENDIO
Z1
CABLE TRAY FIXTURING TYPE
TIPOLOGIA STAFFAGGIO CANALE PORTACAVI
445 cm
APPROXIMATE INSTALLATION HEIGHT OF THE CABLE TRAY
ALTEZZA DI INSTALLAZIONE INDICATIVA DEL CANALE PORTACAVI
PVC RIGID CONDUIT WITH EXPOSED MOUNTING
TUBAZIONE RIGIDA IN PVC CON POSA ESPOSTA
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
N
M
L
I
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
N
M
L
I
H
G
F
E
D
C
B
A
FeR RB
E-001
LEGEND OF ELECTRICAL SYSTEM SYMBOLS
LEGENDA SIMBOLI IMPIANTI ELETTRICI
PROJECT NUMBER
CHECKED BYENGINEERED BYDRAWN BY
BP
DATE SHEET
SYMBOL DESCRIPTION OF REVISION DRAWN DATE APPROVAL
FINAL SUBMISSION
OF SCALE
DMC PWO
U.S. Army Garrison Italy, APO AE 09613
GENERAL REPAIR BUILDING 703
MARCH 2017 AS SHOWN
F
S B l d g
E d w g
AICE
CONSULTING
141ED 00209-5
AutoCAD SHX Text
AC-I
AutoCAD SHX Text I
AutoCAD SHX Text d
AutoCAD SHX Text Q2
AutoCAD SHX Text Q1
AutoCAD SHX Text Q3
AutoCAD SHX Text I
AutoCAD SHX Text d
AutoCAD SHX Text Q2
AutoCAD SHX Text Q1
AutoCAD SHX Text Q3
AutoCAD SHX Text Un
AutoCAD SHX Text 10/16
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AC-E
AutoCAD SHX Text
AC-I
AutoCAD SHX Text Un
AutoCAD SHX Text 10/16
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AC-E
AutoCAD SHX Text Un
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
LED
AutoCAD SHX Text 24V
AutoCAD SHX Text
IF THIS DRAWING IS LESS THAN 841 X 594 mm IT IS A REDUCED SIZE DRAWING
SE QUESTO DISEGNO È PIÙ PICCOLO DI 841 X 594 mm È UN DISEGNO A DIMENSIONI RIDOTTE
NOTE: / NOTA:
ELENCO LAVORAZIONI / RIMOZIONI
WORK / REMOVALS ITEMS
RIMUOVERE TUTTI GLI IMPIANTI ESISTENTI DI ILLUMINAZIONE (ORDINARIA ED EMERGENZA) DEL
LOCALE, COMPRESO CORPI ILLUMINANTI E CONDUTTURE RELATIVE (CAVI, TUBAZIONI,
CANALIZZAZIONI, ECC.), SE NON DIVERSAMENTE E SPECIFICATAMENTE INDICATO.
QUALSIASI APPARECCHIATURA DELL'IMPIANTO ILLUMINAZIONE ESISTENTE NON RAPPRESENTATA
DOVRA' COMUNQUE ESSERE RIMOSSA, QUALORA NON DIVERSAMENTE SEGNALATO.
REMOVE ALL EXISTING LIGHTING SYSTEMS (ORDINARY AND EMERGENCY) OF THE ROOM,
INCLUDING LIGHTING FIXTURES AND RELATED CONDUITS (CABLES, CONDUITS, CABLE TRAYS, ETC.), UNLESS OTHERWISE AND SPECIFICALLY INDICATED.
ANY EXISTING EQUIPMENT OF ORDINARY LIGHTING SYSTEM NOT DRAWN SHALL BE REMOVED
OTHERWISE, UNLESS OTHERWISE REPORTED.
RIMUOVERE, SE NON DIVERSAMENTE E SPECIFICATAMENTE INDICATO, TUTTI GLI IMPIANTI
ESISTENTI F.M. DEL LOCALE, COMPRESO: QUADRI ELETTRICI, PRESE, CAVI, TUBAZIONI,
CANALIZZAZIONI, MOTORIZZAZIONI, COLLEGAMENTI UTENZE/APPARECCHIATURE (VENTILATORI, ASPIRATORI, POMPE, AEROTERMI, UNITA' ARIA CONDIZIONATA), ECC.
QUALSIASI APPARECCHIATURA DELL'IMPIANTO F.M. ESISTENTE NON RAPPRESENTATA DOVRA'
COMUNQUE ESSERE RIMOSSA, QUALORA NON DIVERSAMENTE SEGNALATO.
REMOVE, UNLESS OTHERWISE AND SPECIFICALLY INDICATED, ALL EXISTING POWER SYSTEM OF
THE ROOM, INCLUDING: DISTRIBUTION PANELS, OUTLETS, CABLES, CONDUITS, CABLE TRAYS, ELECTRICAL MOTORS, LOADS/EQUIPMENT CONNECTION (FANS, EXHAUST FANS, PUMPS, FANCOILS, A/C UNITS), ETC.
ANY EXISTING EQUIPMENT OF POER SYSTEM NOT DRAWN SHALL BE REMOVED OTHERWISE,
UNLESS OTHERWISE REPORTED.
ARMADIO ESTERNO PER ATTRAVERSAMENTO ESTERNO-INTERNO DELLA LINEA DORSALE
ELETTRICA DI ALIMENTAZIONE FABBRICATO.
EXTERNAL CABINET FOR EXTERNAL-INTERNAL CROSSING OF THE MAIN FEEDING LINE OF THE
BUILDING.
CENTRALINA PER COMANDO APERTURA/CHIUSURA MOTORIZZAZIONE PORTONE CARRABILE
MOTOR CONTROL PANEL FOR AUTOMATIC OPEN/CLOSE VEHICLE DOOR
ALIMENTAZIONE ESTRATTORE BAGNI E DEPOSITO (LOCALI 10, 11, 19, 21, 22).
RESTROOMS AND STORAGE EXHAUST FAN FEEDING (ROOMS 10, 11, 19, 21, 22).
ALIMENTAZIONE FANCOIL A SOFFITTO/CONTROSOFFITTO
FEEDING OF CEILING/FALSE CEILING FANCOIL
ALIMENTAZIONE GRUPPO COMPRESSORE ARIA
AIR COMPRESSOR GROUP FEEDING
ALIMENTAZIONE ESSICCATORE COMPRESSORE ARIA
AIR COMPRESSOR DRYER FEEDING
ALIMENTAZIONE ESTRATTORE ARIA A SOFFITTO (TORRINO) LOCALE OFFICINA
FEEDING OF AIR EXHAUST FAN ON SHOP AREA ROOF
ILLUMINAZIONE ESTERNA COMANDATA DA RELE' ASTRONOMICO INSTALLATO NEL QUADRO
ELETTRICO GENERALE MDP. COLLEGARE CIASCUN APPARECCHIO ILLUMINANTE MEDIANTE
SCATOLA DI DERIVAZIONE.
EXTERNAL LIGHTING CONTROLLED BY ASTRONOMIC RELAY INSTALLED INSIDE MDP. CONNECT
EACH LIGHTING FIXTURE WITH A JUNCTION BOX.
ALIMENTAZIONE SISTEMA DI ESTRAZIONE FUMI SALDATURA.
FEEDING OF WELDING FUMES EXHAUST FAN SYSTEM.
SEZIONATORE PER GRUPPO ESTRAZIONE GAS DI SCARICO.
SWITCH DISCONNECTOR FOR VEHICLE EXHAUST EVACUATION GROUP.
ALIMENTAZIONE IMPIANTO ESTRAZIONE ARIA OFFICINA.
FEEDING OF SHOP AIR EXTRACTION SYSTEM.
ALIMENTAZIONE POMPE RICIRCOLO P02.
P02 RECYCLING PUMPS FEEDING.
GENERAL NOTES
NOTE GENERALI
TUTTI GLI APPARECCHI ED I CAVI RIPORTATI NEI DISEGNI RELATIVI ALLE NUOVE CONDIZIONI
SONO NUOVI SALVO INDICAZIONE CONTRARIA. GLI IMPIANTI ELETTRICI ESISTENTI SONO
RAPPRESENTATI CON TRATTO SOTTILE, QUELLI DI NUOVA INSTALLAZIONE SONO
RAPPRESENTATI CON TRATTO PIU' MARCATO.
ALL THE DEVICES AND CABLES REPORTED IN NEW CONDITIONS DRAWINGS ARE NEW UNLESS
OTHERWISE INDICATED. EXISTING ELECTRICAL SYSTEMS ARE REPRESENTED BY THIN TRACT, NEW
ELECTRICAL SYSTEM ARE REPRESENTED BY STRONG TRACT.
2-
4-
TUTTE LE MISURE DOVRANNO ESSERE VERIFICATE IN CANTIERE DALL'APPALTATORE.
ALL DIMENSIONS SHALL BE VERIFIED ON SITE BY THE CONTRACTOR.
TUTTE LE APPARECCHIATURE RIMOSSE DOVRANNO ESSERE SMALTITE O RICONSEGNATE AL
GOVERNO AMERICANO SECONDO LE DISPOSIZIONI DEL C.O.R. E A QUANTO INDICATO NEL
CAPITOLATO.
ALL REMOVED EQUIPMENT MUST BE DISPOSED OR RETURNED TO U.S. GOVERNMENT ACCORDING
TO THE C.O.R. AND AS INDICATED ON THE TECHNICAL SPECIFICATION.
1-
5-
RIPRISTINARE LA COMPARTIMENTAZIONE ANTINCENDIO A SEGUITO DELL'ATTRAVERSAMENTO
CON TUBI O CANALI.
RESTORE FIRE COMPARTMENTATION AFTER CROSSING WITH CONDUITS OR CABLE TRAYS
3-
GLI IMPIANTI ESISTENTI (PERCORSI CONDUTTURE, POSIZIONE APPARECCHIATURE, SIGLE
ALIMENTAZIONE, ECC.) RAPPRESENTATI NEGLI ELABORATI GRAFICI SONO STATE RICAVATI
DA AICE CONSULTING IN BASE AI DISEGNI AS-BUILT RICEVUTI DALLA COMMITTENZA ED AL
SOPRALLUOGO EFFETTUATO. L'ESATTA UBICAZIONE DEGLI IMPIANTI POTREBBE DIFFERIRE
DA QUANTO INDICATO. L'APPALTATORE DOVRA' VERIFICARE IN CANTIERE QUANTO
RIPORTATO SULLE TAVOLE.
EXISTING SYSTEMS (CONDUITS WAY, EQUIPMENT LOCATION, ID FEEDING, ETC.) WERE OBTAINED
BY AICE CONSULTING ON THE BASIS OF AS-BUILT DRAWINGS AVAIBLE BY CONTRACTING AND SITE
INSPECTION. THE EXACT LOCATION OF THE SYSTEMS MAY DIFFER FROM THE INDICATED.
CONTRACTOR SHALL VERIFY ON SITE AS SET FORTH ON DRAWINGS.
6-
TUTTI I CAVI UTILIZZATI PER GLI IMPIANTI ELETTRICI SARANNO NON PROPAGANTI L'INCENDIO, A
BASSA EMISSIONE DI FUMI E PRIVI DI ALOGENI "LS0H", TIPO FG7(O)M1.
PER I CIRCUITI TERMINALI SARANNO UTILIZZATI CAVI UNIPOLARI DEL TIPO N07G9-K.
ALL THE CABLES FOR ELECTRICAL SYSTEM WILL BE FIRE RETARDANT, LOW SMOKE ZERO HALOGEN
"LS0H", FG7(O)M1 TYPE.
FOR THE TERMINAL CIRCUITS WILL BE USED UNIPOLAR CABLE, N07G9-K TYPE.
7-
PER LA DESTINAZIONE D'USO DEI LOCALI VEDERE QUANTO RIPORTATO SULLE TAVOLE DEL
PROGETTO ARCHITETTONICO.
FOR THE DESTINATION USE OF THE ROOMS SEE ARCHITECTURAL PROJECT DRAWINGS.
PLAFONIERE INSTALLATE A PARETE, ANGOLATE A 45° (CIRCA 415 CM DAL PAVIMENTO).
LIGHTING FIXTURE WALL MOUNTED WITH TILT 45° (ABOUT 415 CM FROM THE FLOOR) .
LINEA ALIMENTAZIONE FABBRICATO ESISTENTE - DA RIMUOVERE.
EXISTING BUILDING FEEDER LINE - TO REMOVE.
NUOVA LINEA DI ALIMENTAZIONE EDIFICIO, COSTITUITA DA CAVO FG7R 3x(1x95)+1x50N+1x50PE MMQ
POSATA ALL'INTERNO DI CAVIDOTTO INTERRATO ESISTENTE.
NEW BUILDING FEEDING LINE, CONSISTING BY FG7R CABLE 3x(1x95)+1x50N+1x50PE SQMM, INSTALLED INSIDE THE EXISTING UNDERGROUND DUCT BANK
PULSANTE DI EMERGENZA SGANCIO ENERGIA (TIPOLOGIA A LANCIO DI CORRENTE) , PER
INTERROMPERE L'ALIMENTAZIONE ELETTRICA DELL'INTERO EDIFICIO (SGANCIO INTERRUTTORE
EDIFICIO, QUADRO BT CABINA ELETTRICA TS738 ).
EMERGENCY VOLTAGE SHUT DOWN PUSH BUTTON (CURRENT TRIP TYPE), TO INTERRUPT THE
FEEDING OF THE WHOLE BUILDING (SHUT DOWN BUILDIN CIRCUIT BREAKER, LV PANEL TS 738).
ALIMENTAZIONE ELETTROSERRATURA CIFRATA PORTA LOCALE
CYPHER ELECTRIC LOCK FOR ROOM DOOR
TASTIERA NUMERICA A CODICE PER COMANDO ELETTROSERRATURA PORTA
NUMERIC PAD TO CONTROL ELECTRIC LOCK OF ROOM DOOR
PLAFONIERE INSTALLATE SU APPOSITE STAFFE DI SOSTEGNO E ANGOLATE A 45° (CIRCA 415 CM
DAL PAVIMENTO).
LIGHTING FIXTURES INSTALLED ON APPROPRIATE SUPPORT AND TILT 45° (ABOUT 415 CM FROM THE
FLOOR) .
POZZETTO CON DISPERSORE DI TERRA, SEZIONE TRASVERSALE CIRCOLARE PIENA Ø20 MM DI
ACCIAIO RAMATO, Lmin = 3 m.
HANDHOLE WITH GROUNDING ROD , CIRCULAR SOLID CROSS SECTION Ø20 MM, MADE OF COPPER
CLAD STEEL, Lmin = 3 m.
ALIMENTAZIONE SISTEMA IMMISSIONE ARIA NEL LOCALE.
FEEDING OF AIR INTAKE SYSTEM INSIDE ROOM.
COLLEGARE I DISPERSORI TRA LORO CON CORDA IN RAME 35 MMQ DIRETTAMENTE INTERRATA
A 750 MM DI PROFONDITA'.
CONNECTS THE RODS BETWEEN THEM WITH 35 SQMM BARE COPPER CABLE DIRECTLY BURIED AT
750 MM OF DEPTH.
COLLEGARE L'IMPIANTO DI MESSA A TERRA AL COLLETTORE PRINCIPALE DI TERRA "MBG" POSTO
NEL QUADRO ELETTRICO GENERALE "MDP" MEDIANTE CAVO N07V-K GIALLO/VERDE 25 MMQ DA
POSARE NELLE CANALIZZAZIONI PORTACAVI DEGLI IMPIANTI ELETTRICI.
CONNECT THE GROUNDING SYSTEM TO THE MAIN BUILDING GROUNDING BUSBAR "MBG" PLACED
INSIDE THE MAIN DISTRIBUTION PANEL "MDP" TROUGHT N07V-K YELLOW/GREEN 25 SMMQ CABLE TO
INSTALL INSIDE THE ELECTRICAL SYSTEM CABLE TRAYS.
COLLETTORE PRINCIPALE DI TERRA MBG DA INSTALLARE INTERNAMENTE AL NUOVO QUADRO
GENERALE "MDP". COLLEGARE AL COLLETTORE I CONDUTTORI DI PROTEZIONE DEI CIRCUITI
ELETTRICI DERIVATI.
MBG MAIN BUILDING GROUNDING BUSBAR TO INSTALL INSIDE THE NEW MAIN DISTRIBUTION PANEL
"MDP". CONNECT TO THE MBG THE PROTECTION CONDUCTORS OF THE DERIVATED CIRCUITS.
COLLEGARE IL COLLETTORE DI TERRA DELL'IMPIANTO COMUNICAZIONE "TMGB" AL COLLETTORE
PRINCIPALE DI TERRA "MBG" MEDIANTE CAVO N07V-K GIALLO/VERDE 25 MMQ DA POSARE NELLE
CANALIZZAZIONI PORTACAVI E/O TUBAZIONI DEGLI IMPIANTI ELETTRICI.
CONNECT THE COMMUNICATION MAIN GROUNDING BUSBAR "TMGB" TO THE MAIN BUILDING
GROUNDING BUSBAR "MBG" TROUGHT N07V-K YELLOW/GREEN 25 SMMQ CABLE TO INSTALL INSIDE
THE ELECTRICAL SYSTEM CABLE TRAYS AND/OR CONDUITS.
COLLETTORE DI TERRA IMPIANTO COMUNICAZIONE "TMGB" (VEDERE TAVOLE TN101 E TN501).
TELECOMMUNICATION GROUNDING BUSBAR "TMGB" (SEE DRAWINGS TN101 AND TN501).
NUOVA LINEA DI ALIMENTAZIONE EDIFICIO, COSTITUITA DA CAVO FG7R 3x(1x95)+1x50N+1x50PE MMQ
POSATA ALL'INTERNO DI NUOVO CAVIDOTTO INTERRATO .
NEW BUILDING FEEDING LINE, CONSISTING BY FG7R CABLE 3x(1x95)+1x50N+1x50PE SQMM, INSTALLED INSIDE NEW UNDERGROUND DUCT BANK.
ALIMENTAZIONE POMPA DI CALORE.
HEAT PUMP FEEDING.
GIUNZIONE PASSANTE SU CORDA IMPIANTO DI TERRA, REALIZZATA MEDIANTE SALDATURA
ESOTERMICA TIPO CADWELD.
UNINTERRUPTED JUNCTION ON GROUNDING SYSTEM COPPER CONDUCTOR, REALIZED BY
EXOTHERMIC WELDING TYPE CADWELD.
COLLEGARE LA MAGLIA METALLICA DEL BASAMENTO ALL'IMPIANTO DI TERRA CON CORDA NUDA
IN RAME 35 MMQ. CONNESSIONE MEDIANTE SALDATURA ESOTERMICA TIPO CADWELD. .
CONNECT THE METAL MESH BASEMENT TO THE GROUNDING SYSTEM WITH 35 SQMM BARE COPPER
CABLE. CONNECTION REALIZED BY EXOTHERMIC WELDING TYPE CADWELD.
COLLEGARE DUE COLONNE DELLA RECINZIONE ALL'IMPIANTO DI TERRA CON CORDA NUDA IN RAME
35 MMQ .
CONNECT TWO COLUMNS OF THE FENCE TO THE GROUNDING SYSTEM WITH 35 SQMM BARE COPPER
CABLE.
COLLEGARE LA MAGLIA METALLICA DEL BASAMENTO AL COLLETTORE PRINCIPALE DI TERRA
"MBG" POSTO NEL QUADRO ELETTRICO GENERALE "MDP" MEDIANTE CAVO N07V-K GIALLO/VERDE
25 MMQ DA POSARE NELLE CANALIZZAZIONI PORTACAVI DEGLI IMPIANTI ELETTRICI.
CONNECT THE METAL MESH BASEMENT TO THE MAIN BUILDING GROUNDING BUSBAR "MBG"
PLACED INSIDE THE MAIN DISTRIBUTION PANEL "MDP" TROUGHT N07V-K YELLOW/GREEN 25 SMMQ
CABLE TO INSTALL INSIDE THE ELECTRICAL SYSTEM CABLE TRAYS.
CAVO N07V-K GIALLO/VERDE 25 MMQ INSTALLATO IN TUBAZIONE IN ACCIAIO ZINCATO POSATA A
VISTA.
N07V-K YELLOW/GREEN 25 SMMQ CABLE TO INSTALL INSIDE GALVANIZED STEEL CONDUIT WITH
EXPOSED MOUNTING.
POZZETTO IMPIANTI ELETTRICI CON DISPERSORE DI TERRA (SEZIONE TRASVERSALE CIRCOLARE
PIENA Ø20 MM DI ACCIAIO RAMATO, Lmin = 3 m).
ELECTRICAL SYSTEM HANDHOLE WITH GROUNDING ROD (CIRCULAR SOLID CROSS SECTION Ø20
MM, MADE OF COPPER CLAD STEEL, Lmin = 3 m).
8-
TUTTI GLI STAFFAGGI ED I RELATIVI ANCORAGGIO SARANNO DEL TIPO ANTISISMICO, REALIZZATI IN
ACCORDO ALLE INDICAZIONI DI PROGETTO (VEDERE TAVOLE E-504, S-502).
ALL BRACKETS AND ITS ANCHORAGE SHALL BE ANTISEISMIC TYPE, REALIZED IN ACCORDANCE
WITH THE PROJECT INFORMATION (SEE DRAWINGS E-504, S-502).
INSTALLARE ALL'INTERNO DEL QUADRO ELETTRICO MR LE APPARECCHIATURE DELL' IMPIANTO DI
REGOLAZIONE (VEDERE TAVOLA EY601).
INSTALL INSIDE THE MR DISTRIBUTION PANEL THE EQUIPMENT OF THE CONTROL SYSTEM (SEE
DRAWING EY601).
INSTALLARE ALL'INTERNO DEL QUADRO ELETTRICO SP LE APPARECCHIATURE DELL' IMPIANTO DI
REGOLAZIONE (VEDERE TAVOLA EY602).
INSTALL INSIDE THE SP DISTRIBUTION PANEL THE EQUIPMENT OF THE CONTROL SYSTEM (SEE
DRAWING EY602).
PULSANTE COMANDO TERMOSTRISCIA LOCALE SALDATURA (VEDERE TAVOLA EY604)
PUSHBUTTON TO CONTROL THE RADIANT PANEL OF THE WELDING ROOM (SEE DRAWING EY604)
PULSANTE COMANDO TERMOSTRISCIA BAIA 1 LOCALE OFFICINA (VEDERE TAVOLA EY604)
PUSHBUTTON TO CONTROL THE RADIANT PANEL OF SHOP ROOM BAY 1 (SEE DRAWING EY604)
PULSANTI COMANDO TERMOSTRISCIE BAIE 2 E 3 LOCALE OFFICINA (VEDERE TAVOLA EY604)
PUSHBUTTONS TO CONTROL THE RADIANT PANELS OF SHOP ROOM BAY 2 AND 3 (SEE DRAWING
EY604)
PULSANTE COMANDO TERMOSTRISCIA BAIA 4 LOCALE OFFICINA (VEDERE TAVOLA EY604)
PUSHBUTTON TO CONTROL THE RADIANT PANEL OF SHOP ROOM BAY 4 (SEE DRAWING EY604)
CELLA MT ESISTENTE - DA MANTENERE.
EXISTING MV SWITCHGEAR - TO REMAIN.
QUADRO BT ESISTENTE "LVP" - DA MANTENERE.
EXISTING LV PANEL "LVP" - TO REMAIN.
BOX MT CON TRASFORMATORE IN OLIO MT/BT DA 250 kVA. MANTENERE IL BOX DI CONTENIMENTO E
RIMUOVERE IL TRASFORMATORE ESISTENTE.
MV BOX WITH MV/LV OIL TRANSFORMER 250 kVA. MAINTAINING THE CONTAINMENT BOX AND
REMOVE THE EXISTING TRANSFORMER.
QUADRO BT ESISTENTE ALIMENTAZIONE FABBRICATI 738 E 919 - DA RIMUOVERE.
EXISTING LV PANEL TO FEEDING BUILDINGS 738 AND 919 - TO REMOVE.
QUADRO BT ESISTENTE ILLUMINAZIONE ESTERNA - DA MANTENERE.
EXISTING LV EXTERNAL LIGHTING PANEL - TO REMAIN.
QUADRO RIFASAMENTO AUTOMATICO ESISTENTE - DA MANTENERE.
EXISTING POWER FACTOR UNIT - TO REMAIN.
NUOVO TRASFORMATORE IN RESINA MT/BT DA ALLOGGIARE ALL'INTERNO DEL BOX ESISTENTE.
CARATTERISTICHE: CLASSE A0Ak, POTENZA NOMINALE 400 kVA, TENSIONE PRIMARIO 10 kV, DOPPIO
SECONDARIO 400 V E 230 V, Dyn 11, vcc=6%. AVVOLGIMENTI SECONDARI CON SONDE TERMICHE
INGLOBATE.
NEW MV/LV DRY TYPE TRANSFORMER TO INSTALL INSIDE EXISTING BOX.
TECHNICAL DATA: CLASS A0Ak. NOMINAL POWER 400 kVA, PRIMARY VOLTAGE 10 kV, DOUBLE
SECONDARY 400 V AND 230 V, Dyn 11, vsc=6%. LV WINDINGS SHALL HAVE INCORPORATED THERMAL
PROBES.
NUOVO QUADRO BT ALIMENTAZIONE FABBRICATI 738 E 919, DA COLLEGARE DIRETTAMENTE SUL
SECONDARIO 400 V DEL TRASFORMATORE MEDIANTE LINEA IN CAVO FG7R 3x(1x240)+1x120+1G120
MMQ DA INSTALLARE NEL CAVEDIO ESISTENTE.
PER MAGGIORI DETTAGLI VEDERE TAVOLE EP601, E-505, E-506.
NEW LV PANEL TO BUILDINGS 738 AND 919 FEEDING, TO CONNECT DIRECTLY ON 400 V SECONDARY
WIRING OF THE TRANSFORMER THROUGHT CABLE LINE FG7R 3x(1x240)+1x120+1G120 SQMM TO
INSTALL INSIDE TO THE EXISTING SHAFT.
FOR MORE DETAILS SEE DRAWINGS EP601, E-505, E-506.
CONDENSATORI ESISTENTI PER RIFASAMENTO TRASFORMATORE MT/BT - DA RIMUOVERE.
EXISTING CAPACITORS TO MV/LV TRANSFORMER CORRECTION - TO REMOVE.
CONDENSATORI PER RIFASAMENTO NUOVO TRASFORMATORE MT/BT, 4 kVAR.
CAPACITORS FOR NEW MV/LV TRANSFORMER PF CORRECTION, 4 kVAR.
ALIMENTAZIONE RESISTENZA DI RISCALDAMENTO VOLANO TERMICO.
FEEDING OF HEATER RESISTOR OF PUFFER TANK.
ALIMENTAZIONE GRUPPO ESTRAZIONE GAS DI SCARICO: INSTALLARE UN SEZIONATORE IN
PROSSIMITA' DELL'ALIMENTAZIONE, PER CONSENTIRE LA RISPETTIVA MANUTENZIONE.
VEHICLE EXHAUST EVACUATION GROUP FEEDING: INSTALLING A SWITCH DISCONNECTOR NEAR
THE FEEDING, TO ALLOW ITS MAINTENANCE.
ALIMENTAZIONE POMPE PRIMARIO P01.
P01 PRIMARY PUMPS FEEDING.
ALIMENTAZIONE SCALDA-ACQUA A POMPA DI CALORE.
FEEDING OF HOT WATER BOILER WITH HEAT PUMP.
SEZIONATORE PER PONTE MOBILE SOLLEVAMENTO AUTOMEZZI.
SWITCH DISCONNECTOR FOR VEHICLE LIFTING EQUIPMENT.
APPARECCHIO DI EMERGENZA 400LM CON PITTOGRAMMA DI USCITA DI EMERGENZA, INSTALLATO
A PARETE H=2,5M DA TERRA
400LM EMERGENCY LIGHTING FIXTURE WITH EMERGENCY EXIT SIGN, WALL MOUNTED AT H=2,5M
FROM FLOOR
RICOLLEGARE I QUADRI ESISTENTI AL NUOVO TRASFORMATORE UTILIZZANDO I CAVI ESISTENTI
RE-CONNECT THE EXISTING PANELS TO THE NEW TRANSFORMER UTILIZING THE EXISTING CABLES
FeR RB
E-002
WORK AND REMOVAL ITEMS OF ELECTRICAL SYSTEMS
ELENCO LAVORAZIONI E RIMOZIONI IMPIANTI ELETTRICI
PROJECT NUMBER
CHECKED BYENGINEERED BYDRAWN BY
BP
DATE SHEET
SYMBOL DESCRIPTION OF REVISION DRAWN DATE APPROVAL
FINAL SUBMISSION
OF SCALE
DMC PWO
U.S. Army Garrison Italy, APO AE 09613
GENERAL REPAIR BUILDING 703
MARCH 2017 AS SHOWN
F
S B l d g
E d w g
AICE
CONSULTING
141ED 00209-5
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
N
M
L
I
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
N
M
L
I
H
G
F
E
D
C
B
A
TO "MDP"
E x
E x
E x
E x
E x
E x
E S x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E S x
E S x
E S x
E S x
E S x
E x
E x
E x
E x
E x
E x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
Ex
Ex Ex
ESx ESx
ESx
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
ED101
REMOVALS NOTES
NOTE RIMOZIONI
1-
GLI IMPIANTI ESISTENTI (PERCORSI CONDUTTURE, POSIZIONE APPARECCHIATURE, SIGLE
ALIMENTAZIONE, ECC.) RAPPRESENTATI NEGLI ELABORATI GRAFICI SONO STATI RICAVATI DA "AICE
CONSULTING" IN BASE AI DISEGNI RICEVUTI DALLA COMMITTENZA ED AI SOPRALLUOGHI ESEGUITI.
L'ESATTA UBICAZIONE DEGLI IMPIANTI POTREBBE DIFFERIRE DA QUANTO INDICATO. L'APPALTATORE
DOVRA' VERIFICARE IN CANTIERE QUANTO RIPORTATO SULLE TAVOLE DELLO STATO ATTUALE.
EXISTING SYSTEMS (CONDUITS WAY, EQUIPMENT LOCATION, ID FEEDING, ETC.) SHOWED IN THE
DRAWINGS WERE OBTAINED BY "AICE CONSULTING" ON THE BASIS OF DRAWINGS RECEIVED BY
CUSTOMER AND SITE INSPECTIONS. THE EXACT LOCATION OF THE SYSTEMS MAY DIFFER FROM THE
INDICATED. CONTRACTOR SHALL VERIFY ON SITE AS SET FORTH ON EXISTING CONDITION DRAWINGS.
2-
TUTTE LE APPARECCHIATURE RIMOSSE DOVRANNO ESSERE SMALTITE O RICONSEGNATE AL GOVERNO
AMERICANO SECONDO LE DISPOSIZIONI DEL C.O.R. ED A QUANTO INDICATO NEL CAPITOLATO.
ALL REMOVED EQUIPMENT MUST BE DISPOSED OR RETURNED TO U.S. GOVERNMENT ACCORDING TO
THE C.O.R. AND AS INDICATED ON THE TECHNICAL SPECIFICATION.
IF THIS DRAWING IS LESS THAN 841 X 594 mm IT IS A REDUCED SIZE DRAWING
SE QUESTO DISEGNO È PIÙ PICCOLO DI 841 X 594 mm È UN DISEGNO A DIMENSIONI RIDOTTE
NOTE: / NOTA:
m
1:100
0'
10'
0 1 2 3
20'
4 5 ft 30'
LVP
MVS
MVS
MVS
MVS
1 3 2
TRF 250kVA
PLANIMETRIA TS738: STATO ATTUALE
SCALE / SCALA
ED101
1:50
NORTH
PLAN
PFU
ELP
A
TS738 PLAN: EXISTING CONDITION
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
N
M
L
I
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
N
M
L
I
H
G
F
E
D
C
B
A
FeR RB
ED101
EXISTING CONDITION - BUILDING FEEDER LINE: REMOVALS
STATO ATTUALE - LINEA DI ALIMENTAZIONE FABBRICATO: RIMOZIONI
PROJECT NUMBER
CHECKED BYENGINEERED BYDRAWN BY
BP
DATE SHEET
SYMBOL DESCRIPTION OF REVISION DRAWN DATE APPROVAL
FINAL SUBMISSION
OF SCALE
DMC PWO
U.S. Army Garrison Italy, APO AE 09613
GENERAL REPAIR BUILDING 703
MARCH 2017 AS SHOWN
F
S B l d g
E
D d w g
AICE
CONSULTING
141ED 00209-5
EXISTING FEEDER LINE: REMOVALS / LINEA ALIMENTAZIONE ESISTENTE: RIMOZIONI
SCALE / SCALA 1:100
H
H
H
H
H
H
Tc
EX
MDP
3P-220/380V
Tc
Tc sv sv
EX
sv
MRP
sv sv sv sv
Tc n.3 n.3 n.3 n.3 n.3 n.3 n.3 n.3 n.5 n.4 n.3 n.3 n.3 n.3 n.3 n.3 n.3 n.3 n.3
07 06
REMOVALS NOTES
NOTE RIMOZIONI
1-
GLI IMPIANTI ESISTENTI (PERCORSI CONDUTTURE, POSIZIONE APPARECCHIATURE, SIGLE
ALIMENTAZIONE, ECC.) RAPPRESENTATI NEGLI ELABORATI GRAFICI SONO STATI RICAVATI DA "AICE
CONSULTING" IN BASE AI DISEGNI RICEVUTI DALLA COMMITTENZA ED AI SOPRALLUOGHI ESEGUITI.
L'ESATTA UBICAZIONE DEGLI IMPIANTI E LA QUANTITA' DELLE APPARECCHIATURE ELETTRICHE
POTREBBE DIFFERIRE DA QUANTO INDICATO. L'APPALTATORE DOVRA' VERIFICARE IN CANTIERE
QUANTO RIPORTATO SULLE TAVOLE DELLO STATO ATTUALE.
EXISTING SYSTEMS (CONDUITS WAY, EQUIPMENT LOCATION, ID FEEDING, ETC.) SHOWED IN THE
DRAWINGS WERE OBTAINED BY "AICE CONSULTING" ON THE BASIS OF DRAWINGS RECEIVED BY
CUSTOMER AND SITE INSPECTIONS. THE EXACT LOCATION OF THE SYSTEMS AND THE QUANTITY OF
EQUIPMENTS MAY DIFFER FROM THE INDICATED. CONTRACTOR SHALL VERIFY ON SITE AS SET FORTH
ON EXISTING CONDITION DRAWINGS.
2-
TUTTE LE APPARECCHIATURE RIMOSSE DOVRANNO ESSERE SMALTITE O RICONSEGNATE AL GOVERNO
AMERICANO SECONDO LE DISPOSIZIONI DEL C.O.R. ED A QUANTO INDICATO NEL CAPITOLATO.
ALL REMOVED EQUIPMENT MUST BE DISPOSED OR RETURNED TO U.S. GOVERNMENT ACCORDING TO
THE C.O.R. AND AS INDICATED ON THE TECHNICAL SPECIFICATION.
m
1:100
0'
10'
0 1 2 3
20'
4 5 ft 30'
IF THIS DRAWING IS LESS THAN 841 X 594 mm IT IS A REDUCED SIZE DRAWING
SE QUESTO DISEGNO È PIÙ PICCOLO DI 841 X 594 mm È UN DISEGNO A DIMENSIONI RIDOTTE
NOTE: / NOTA:
3-
RIMUOVERE TUTTI GLI IMPIANTI ELETTRICI ESISTENTI DELL'EDIFICIO, POSTI INTERNAMENTE ED
ESTERNAMENTE, INCLUSO (MA NON LIMITATO): QUADRI ELETTRICI, CAVI, TUBAZIONI, APPARECCHI DI
ILLUMINAZIONE, PRESE DI ENERGIA, ECC. QUALSIASI APPARECCHIATURA E/O PARTE DI IMPIANTO
ELETTRICO NON RAPPRESENTATO NELLE TAVOLE DELLO STATO ATTUALE DOVRA' COMUNQUE ESSERE
RIMOSSO, SE NON DIVERSAMENTE E SPECIFICATAMENTE INDICATO.
REMOVE ALL EXISTING ELECTRICAL SYSTEM OF THE BUILDING, INTERNAL AND EXTERNAL PLACED, INCLUDING (BUT NOT LIMITED): PANELS, CABLES, CONDUITS, LIGHTING FIXTURES, POWER OUTLETS, ETC. ANY DEVICE AND/OR ELECTRICAL SYSTEM NOT DRAWN ON EXISTING CONDITION DRAWINGS
SHALL BE REMOVED, UNLESS OTHERWISE AND SPECIFICALLY INDICATED.
NORTH
PLAN
4-
PER L'ELENCO VOCI DELLE LAVORAZIONI/RIMOZIONI VEDERE LA TAVOLA E-002.
FOR THE ITEM LIST OF WORK/REMOVALS SEE DRAWING E-002.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
N
M
L
I
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
N
M
L
I
H
G
F
E
D
C
B
A
FeR RB
ED102
EXISTING CONDITION - LIGHTING AND POWER ELECTRICAL SYSTEM: REMOVALS
STATO ATTUALE - IMPIANTO ELETTRICO LUCE E F.M.: RIMOZIONI
PROJECT NUMBER
CHECKED BYENGINEERED BYDRAWN BY
BP
DATE SHEET
SYMBOL DESCRIPTION OF REVISION DRAWN DATE APPROVAL
FINAL SUBMISSION
OF SCALE
DMC PWO
U.S. Army Garrison Italy, APO AE 09613
GENERAL REPAIR BUILDING 703
MARCH 2017 AS SHOWN
F
S B l d g
E
D d w g
AICE
CONSULTING
141ED 00209-5
EXISTING LIGHTING SYSTEM: REMOVALS / IMPIANTO ILLUMINAZIONE ESISTENTE: RIMOZIONI
SCALE / SCALA 1:100
EXISTING POWER SYSTEM: REMOVALS / IMPIANTO F.M. ESISTENTE: RIMOZIONI
SCALE / SCALA 1:100
AutoCAD SHX Text 2x58W
AutoCAD SHX Text 2x58W
AutoCAD SHX Text 2x58W
AutoCAD SHX Text 2x58W
AutoCAD SHX Text 2x58W
AutoCAD SHX Text 2x58W
AutoCAD SHX Text 2x58W
AutoCAD SHX Text 2x58W
AutoCAD SHX Text 2x58W
AutoCAD SHX Text 2x58W
AutoCAD SHX Text 2x58W
AutoCAD SHX Text 2x58W
AutoCAD SHX Text 2x58W
AutoCAD SHX Text 2x58W
AutoCAD SHX Text 2x58W
AutoCAD SHX Text 2x58W
AutoCAD SHX Text 2x58W
AutoCAD SHX Text 2x58W
AutoCAD SHX Text 2x58W
AutoCAD SHX Text 2x58W
AutoCAD SHX Text 2x58W
AutoCAD SHX Text 2x58W
AutoCAD SHX Text 2x58W
AutoCAD SHX Text 2x58W
AutoCAD SHX Text 2x58W
AutoCAD SHX Text 2x58W
AutoCAD SHX Text 2x58W
AutoCAD SHX Text 2x58W
AutoCAD SHX Text 2x58W
AutoCAD SHX Text P1
AutoCAD SHX Text 10/16
AutoCAD SHX Text 10/16
AutoCAD SHX Text Un
AutoCAD SHX Text 10/16
AutoCAD SHX Text 10/16
AutoCAD SHX Text 10/16
AutoCAD SHX Text
AC-I
AutoCAD SHX Text
AC-E
AutoCAD SHX Text U
AutoCAD SHX Text Un
AutoCAD SHX Text Un
AutoCAD SHX Text Un
AutoCAD SHX Text
AutoCAD SHX Text 10/16
AutoCAD SHX Text Un
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 10/16
AutoCAD SHX Text 10/16
AutoCAD SHX Text Un
AutoCAD SHX Text
AutoCAD SHX Text Un
AutoCAD SHX Text
AutoCAD SHX Text 10/16
AutoCAD SHX Text Un
AutoCAD SHX Text
AutoCAD SHX Text
AC-I
AutoCAD SHX Text 10/16
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 10/16
AutoCAD SHX Text 10/16
AutoCAD SHX Text Un
AutoCAD SHX Text
AutoCAD SHX Text Un
AutoCAD SHX Text
AutoCAD SHX Text 10/16
AutoCAD SHX Text Un
AutoCAD SHX Text 10/16
AutoCAD SHX Text
AC-I
AutoCAD SHX Text 10/16
AutoCAD SHX Text 10/16
AutoCAD SHX Text 10/16
AutoCAD SHX Text 10/16
AutoCAD SHX Text
AC-I
AutoCAD SHX Text 10/16
AutoCAD SHX Text 10/16
AutoCAD SHX Text 10/16
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AC-E
AutoCAD SHX Text
AC-E
AutoCAD SHX Text Un
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 10/16
AutoCAD SHX Text 10/16
AutoCAD SHX Text 10/16
AutoCAD SHX Text 10/16
AutoCAD SHX Text 10/16
AutoCAD SHX Text 10/16
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Un
AutoCAD SHX Text
AC-I
AutoCAD SHX Text
AC-I
AutoCAD SHX Text 10/16
AutoCAD SHX Text 10/16
AutoCAD SHX Text 10/16
AutoCAD SHX Text Un
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AC-I
AutoCAD SHX Text Un
AutoCAD SHX Text Un
AutoCAD SHX Text Un
AutoCAD SHX Text Un
AutoCAD SHX Text Un
AutoCAD SHX Text Un
AutoCAD SHX Text
AutoCAD SHX Text Un
AutoCAD SHX Text Un
AutoCAD SHX Text Un
AutoCAD SHX Text Un
AutoCAD SHX Text Un
AutoCAD SHX Text Un
AutoCAD SHX Text
AC-E
AC-E
E x
E x
E x
E x
E x
E x
E S x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E S x
E S x
E x
E x
E x
E x
E x
E x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
Ex
Ex Ex
ESx ESx
ESx
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
E
S x
TO "MDP"
E
S
E
S
E
S
E
S
E
S
E
S
E
S
E
S
E
S
E-501
E-501
ES101
E-501 m
1:100
0'
10'
0 1 2 3
20'
4 5 ft 30'
IF THIS DRAWING IS LESS THAN 841 X 594 mm IT IS A REDUCED SIZE DRAWING
SE QUESTO DISEGNO È PIÙ PICCOLO DI 841 X 594 mm È UN DISEGNO A DIMENSIONI RIDOTTE
NOTE: / NOTA:
NOTES
NOTE
1-
DISTANZA "dg" ³ 15 cm
DISTANZA "dg" ³ 15 cm
2.00
1:50
2'0' 1'
0 0.50
4'3' 5'
1.00 4.003.00
10' 15'
5.00 ft m
PLANIMETRIA TS738: CONDIZ. DI PROGETTO
SCALE / SCALA
ES101
1:50
NORTH
PLAN
LVP
PFU
ELP
A
MVSMVSMVSMVS
dg d g dg d g
TRF 400kVA
A
E-301
A
E-301
TS738 PLAN: PROJECT CONDITION
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
N
M
L
I
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
N
M
L
I
H
G
F
E
D
C
B
A
FeR RB
ES101
PROJECT CONDITION - BUILDING FEEDER LINE
CONDIZIONE DI PROGETTO - LINEA ALIMENTAZIONE FABBRICATO
PROJECT NUMBER
CHECKED BYENGINEERED BYDRAWN BY
BP
DATE SHEET
SYMBOL DESCRIPTION OF REVISION DRAWN DATE APPROVAL
FINAL SUBMISSION
OF SCALE
DMC PWO
U.S. Army Garrison Italy, APO AE 09613
GENERAL REPAIR BUILDING 703
MARCH 2017 AS SHOWN
F
S B l d g
E
S d w g
AICE
CONSULTING
141ED 00209-5
BUILDING FEEDER LINE: PROJECT CONDITION / LINEA ALIMENTAZIONE FABBRICATO: CONDIZIONE DI PROGETTO
SCALE / SCALA 1:100
MDP
MR
CR
SP
08 07
HP
E
S
E
S
FROM TS 738
E-501
E-501
C
E-505
E-505
E-505
E-505
E-101
Z3
Z3
Z1
Z2
Z1
Z3
Z3
Z3
Z3
445 cm
360 cm
360 cm
360 cm
360 cm
470 cm
445 cm
360 cm
360 cm
360 cm
360 cm
360 cm
360 cm
445 cm
360 cm m
1:100
0' 10'
0 1 2 3
20'
4 5 ft30'
IF THIS DRAWING IS LESS THAN 841 X 594 mm IT IS A REDUCED SIZE DRAWING
SE QUESTO DISEGNO È PIÙ PICCOLO DI 841 X 594 mm È UN DISEGNO A DIMENSIONI RIDOTTE
NOTE: / NOTA:
NORTH
PLAN
NOTES
NOTE
1-
LA DISTRIBUZIONE DORSALE DEGLI IMPIANTI ELETTRICI (ILLUMINAZIONE E F.M.) NELL'AREA OFFICINA SARA' REALIZZATA
MEDIANTE CANALE PORTACAVI IN ACCIAIO ZINCATO CON COPERCHIO, GRADO DI PROTEZIONE IP4X, INSTALLATO A PARETE
E SOFFITTO.
LE DERIVAZIONI SARANNO ESEGUITE MEDIANTE TUBAZIONI IN ACCIAIO ZINCATO CON POSA ESPOSTA, GRADO DI
PROTEZIONE IP67.
THE MAIN DISTRIBUTION OF THE ELECTRICAL SYSTEMS (LIGHTING AND POWER) INSIDE OF SHOP AREA WILL BE REALIZED
BY GALVANIZED STEEL CABLE TRAY WITH COVER, IP4X PROTECTION DEGREE, INSTALLED TO WALL AND CEILING.
THE DERIVATIONS WILL REALIZED BY GALVANIZED STEEL CONDUITS WITH EXPOSED MOUNTING, IP67 PROTECTION
DEGREE.
2-
LA DISTRIBUZIONE DORSALE DEGLI IMPIANTI ELETTRICI (ILLUMINAZIONE E F.M.) NELL'AREA AMMINISTRATIVA (LATO UFFICI)
SARA' REALIZZATA MEDIANTE PASSERELLA A FILO IN ACCIAIO ZINCATO CON COPERCHIO, INSTALLATA SOPRA I
CONTROSOFFITTI.
LE DERIVAZIONI SARANNO ESEGUITE MEDIANTE:
- SOPRA IL CONTROSOFFITTO: TUBAZIONI RIGIDE E GUAINE FLESSIBILI IN PVC
- SOTTO IL CONTROSOFFITTO: TUBAZIONI FLESSIBILI INCASSATE A PARETE
THE MAIN DISTRIBUTION OF THE ELECTRICAL SYSTEMS (LIGHTING AND POWER) INSIDE AMMINISTRATIVE AREA (OFFICES
SIDE) WILL BE REALIZED BY GALVANIZED STEEL WIRE CABLE TRAY WITH COVER, INSTALLED ABOVE FALSE CEILINGS.
THE DERIVATIONS WILL REALIZED BY:
- ABOVE FALSE CEILING: PVC RIGID CONDUITS AND PVC CABLE SHEATH
- BELOW FALSE CEILING: PVC FLEXIBLE CONDUITS ENCASED INTO WALLS
3-
LE ALTEZZE DI INSTALLAZIONE DELLE CANALIZZAZIONI INDICATE SONO RIFERITE DAL PIANO DI CALPESTIO ALLA BASE
INFERIORE DEL CANALE; LE STESSE SONO DA RITENERSI SOLO INDICATIVE, DA VERIFICARSI IN CANTIERE DURANTE
L'ESECUZIONE DELL'INSIEME DELLE OPERE .
THE HEIGHTS SHOWN OF CABLE TRAY INSTALLATION ARE REFERRED FROM THE FLOOR TO THE CABLE TRAY BOTTOM;
THESE DIMENSIONS ARE AS INDICATIVE ONLY, TO VERIFY IN SITE DURING THE REALIZATION OF THE WHOLE WORK.
COMPARTIMENTAZIONI ANTINCENDIO
FIRE COMPARTMENTATION
COLLOCAZIONE QUADRI LOCALE ELETTRICO "07"
PLACING PANELS INSIDE ELECTRICAL ROOM "07"
SCALE / SCALA
E-101
1:20
2.00
6' m ft
0.80 1.00
4'
0.600.40
2'
0.200
0'
1:20
1' 3' 5'
SISTEMI DI STAFFAGGIO
BRACKETING SYSTEM
STAFFAGGIO CON MENSOLA A PARETE
MOUNTING WITH WALL BRACKET
Z3
STAFFAGGIO CON BINARIO SOTTOTRAVE (SINGOLO)
MOUNTING WITH SECTION BAR UNDERBEAM (SINGLE)
Z1
STAFFAGGIO CON BINARIO SOTTOTRAVE (DOPPIO)
MOUNTING WITH SECTION BAR UNDERBEAM (DOUBLE)
Z2
S-502
S-502
E-504
4-
PER L'ELENCO VOCI DELLE LAVORAZIONI VEDERE LA TAVOLA E-002.
FOR THE ITEM LIST OF WORK SEE DRAWING E-002.
MDP
ACU
B
E-301
C
E-301
85 120
C
E-301
B
E-301
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
N
M
L
I
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
N
M
L
I
H
G
F
E
D
C
B
A
FeR RB
E-101
PROJECT CONDITION - ELECTRICAL SYSTEMS MAIN DISTRIBUTION
CONDIZIONE DI PROGETTO - DISTRIBUZIONE DORSALE IMPIANTI ELETTRICI
PROJECT NUMBER
CHECKED BYENGINEERED BYDRAWN BY
BP
DATE SHEET
SYMBOL DESCRIPTION OF REVISION DRAWN DATE APPROVAL
FINAL SUBMISSION
OF SCALE
DMC PWO
U.S. Army Garrison Italy, APO AE 09613
GENERAL REPAIR BUILDING 703
MARCH 2017 AS SHOWN
F
S B l d g
E d w g
AICE
CONSULTING
141ED 00209-5
CABLE TRAY OF ELECTRICAL SYSTEMS MAIN DISTRIBUTION (LIGHTING AND POWER)
DISTRIBUZIONE DORSALE CANALE IMPIANTI ELETTRICI (ILLUMINAZIONE E ENERGIA)
SCALE / SCALA 1:100
AutoCAD SHX Text 150x75
AutoCAD SHX Text 300x75
AutoCAD SHX Text 300x75
AutoCAD SHX Text 100x75
AutoCAD SHX Text 300x75
AutoCAD SHX Text 150x75
AutoCAD SHX Text 150x75
AutoCAD SHX Text 300x75
150x75
NOTE: / NOTA:
PARETE EST LOCALE ELETTRICO "07"
ELECTRICAL ROOM "07" EAST WALL
SCALE / SCALA
E-101
C
1:20
PARETE SUD LOCALE ELETTRICO "07"
ELECTRICAL ROOM "07" SOUTH WALL
SCALE / SCALA
E-101
B
1:20
2.00
6' m ft
0.80 1.00
4'
0.600.40
2'
0.200
0'
1:20
1' 3' 5'
NORTH SIDE INTERNAL WALL, TS738 / PARETE INTERNA LATO NORD, CABINA TS738
SCALE / SCALA
ES101
A
1:20
NOTES
NOTE
1-
GLI IMPIANTI ELETTRICI RIPORTATI NELLE SEZIONI SONO DA RITENERSI SOLO A SCOPO INDICATIVO PER LA RISPETTIVA
REALIZZAZIONE.
THE ELECTRICAL SYSTEMS DRAWN IN SECTION ARE TO BE CONSIDERED AS GUIDELINES ONLY FOR THEIR REALIZATION.
MDP
ACU
ROOM 07
CONTROSOFFITTO
FALSE CEILING
CANALE PORTACAVI IN ACCIAIO ZINCATO
CON COPERCHIO(IMPIANTI ELETTRICI)
GALVANIZED STEEL CABLE TRAY WITH
COVER (ELECTRICAL SYSTEMS)
R O
O M
R O
ACU
MDP
CONTROSOFFITTO
FALSE CEILING
ROOM 09
R O
ROOM 06
PASSERELLA METALLICA A FILO IN ACCIAIO
ZINCATO CON COPERCHIO (IMP. ALLARME)
WIRE GALVANIZED STEEL CABLE TRAY WITH
COVER (ALARM SYSTEMS)
CANALE PORTACAVI IN ACCIAIO ZINCATO
CON COPERCHIO (IMP. ALLARME)
GALVANIZED STEEL CABLE TRAY WITH
COVER (ALARM SYSTEMS)
PASSERELLA METALLICA A FILO IN ACCIAIO
ZINCATO CON COPERCHIO (IMP. ELETTRICI)
WIRE GALVANIZED STEEL CABLE TRAY WITH
COVER (ELECTRICAL SYSTEMS)
CANALE PORTACAVI IN ACCIAIO ZINCATO
CON COPERCHIO (IMP. ELETTRICI)
GALVANIZED STEEL CABLE TRAY WITH
COVER (ELECTRICAL SYSTEMS)
Is d (x
Ir)
125 140
175200
Ir (A
M o d e
O K
Ir tr
Is d ts d
Ii (x In
N
/A
/B
/C
A
Ready
A
Micrologic
C o m p a c t
N S
X
U im p U i
Ic c k A
Ic s U e
/6
H z
IE
C
/ E N
-2
N E
M A
A B
NSX400
NEMA AB1
IEC / EN 60947-2
50/60 Hz
Compact
Ue
Icc (kA)Ics
Ui Uimp
NSX
NEMA AB1
IEC / EN 60947-2
50/60 Hz
Compact
Ue
Icc (kA)Ics
Ui Uimp
NSX
4 5
Isd (x Ir)
Ir (A)
Mode OK
Ir tr Isd tsd Ii (xIn)
N 1/A 2/B 3/C
250 AR
e a d y
>30A >90 >105
M i c r o l o g i c
4 5
Isd (x Ir)
Ir (A)
Mode OK
Ir tr Isd tsd Ii (xIn)
N 1/A 2/B 3/C
250 AR
e a d y
>30A >90 >105
M i c r o l o g i c
NSX250 NSX100
S I S
T E
A
G
M
QUADRO BASSA TENSIONE "LVP" ESISTENTE
EXISTING LOW VOLTAGE PANEL "LVP"
NUOVO QUADRO
ELETTRICO "A"
NEW "A" PANEL
QUADRO ELETTRICO ESISTENTE "ELP"
ILLUMINAZIONE ESTERNA
EXISTING "ELP" PANEL FOR EXTERNAL
LIGHTING
QUADRO RIFASAMENTO AUTOMATICO
ESISTENTE
EXISTING POWER FACTOR CORRECTION
PANEL
NUOVO CANALE IN ACCIAIO ZINCATO CON
COPERCHIO, DIM. 200x75 mm
NEW GALVANIZED STELL CABLE TRAY WITH
COVER, DIM. 200x75 mm
CAVEDIO CAVI ESISTENTE CON LAMIERA DI
COPERTURA
EXISTING CABLE SHAFT WITH METAL SHEET
COVER
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
N
M
L
I
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
N
M
L
I
H
G
F
E
D
C
B
A
FeR RB
E-301
PROJECT CONDITION: ELECTRICAL SYSTEMS, SECTIONS A-B-C
CONDIZIONE DI PROGETTO: IMPIANTI ELETTRICI, SEZIONI A-B-C
PROJECT NUMBER
CHECKED BYENGINEERED BYDRAWN BY
BP
DATE SHEET
SYMBOL DESCRIPTION OF REVISION DRAWN DATE APPROVAL
FINAL SUBMISSION
OF SCALE
DMC PWO
U.S. Army Garrison Italy, APO AE 09613
GENERAL REPAIR BUILDING 703
MARCH 2017 AS SHOWN
F
S B l d g
E
E
E
E
E d w g
AICE
CONSULTING
141ED 00209-5
NOTE: / NOTA:
ELECTRICAL SYSTEMS INSTALLATION DETAIL: SECTION "D" / DETTAGLIO INSTALLAZIONE IMPIANTI ELETTRICI: SEZIONE "D"
SCALE / SCALA
EL101 - EP101
D
1:25
1.00
1:25
0' 2.5'
0 0.50
5' ft7.5'
2.001.50 2.50 m
NOTES
NOTE
1-
GLI IMPIANTI ELETTRICI RIPORTATI NELLE SEZIONI SONO DA RITENERSI SOLO A SCOPO INDICATIVO PER LA RISPETTIVA
REALIZZAZIONE.
THE ELECTRICAL SYSTEMS DRAWN IN SECTION ARE TO BE CONSIDERED AS GUIDELINES ONLY FOR THEIR REALIZATION.
GRUPPO PRESE CEE (IP66)
CEE OUTLETS BATTERY (IP66)
GRUPPO PRESE CEE (IP66)
CEE OUTLETS BATTERY (IP66)
CANALE PORTACAVI IN ACCIAIO
ZINCATO CON COPERCHIO (IP4X)
- IMPIANTI ELETTRICI
GALVANIZED STEEL CABLETRAY WITH
COVER (IP4X)
- ELECTRICAL SYSTEMS
CANALE PORTACAVI IN ACCIAIO
ZINCATO CON COPERCHIO (IP4X)
- IMPIANTI COMUNICAZIONE
GALVANIZED STEEL CABLETRAY WITH
COVER (IP4X)
- COMMUNICATION SYSTEMS
CANALE PORTACAVI IN ACCIAIO ZINCATO CON
COPERCHIO E SEPARATORE METALLICO (IP4X)
- IMPIANTI ALLARME INCENDIO, NOTIFICA
ALLARMI E IMPIANTI SPECIALI
GALVANIZED STEEL CABLETRAY WITH COVER
AND METAL SEPARATOR (IP4X)
- FIRE ALARM, MNS AND AUXILIARY SYSTEMS
STAFFAGGIO IN ACCORDO CON LE
NORME ANTISISMICHE
BRACKET IN ACCORDANCE WITH
SEISMIC NORMS
STAFFAGGIO IN ACCORDO CON LE
NORME ANTISISMICHE
BRACKET IN ACCORDANCE WITH
SEISMIC NORMS
GRUPPO PRESE CEE (IP66)
CEE OUTLETS BATTERY (IP66)
CENTRALINA COMANDO
MOTORIZZAZIONE SERRANDA
MOTOR CONTROL PANEL
AUTOMATIC DOOR
CENTRALINA COMANDO
MOTORIZZAZIONE SERRANDA
MOTOR CONTROL PANEL
AUTOMATIC DOOR
PLAFONIERE ILLUMINAZIONE SOSPESE (IP65)
SUSPENDED LIGHTING FIXTURES (IP65)
PLAFONIERE ILLUMINAZIONE SOSPESE (IP65)
SUSPENDED LIGHTING FIXTURES (IP65)
STAFFAGGIO IN ACCORDO CON LE
NORME ANTISISMICHE
BRACKET IN ACCORDANCE WITH
SEISMIC NORMS
CANALE PORTACAVI IN ACCIAIO
ZINCATO CON COPERCHIO (IP4X)
- IMPIANTI ELETTRICI
GALVANIZED STEEL CABLETRAY WITH
COVER (IP4X)
- ELECTRICAL SYSTEMS
CANALE PORTACAVI IN ACCIAIO
ZINCATO CON COPERCHIO (IP4X)
- IMPIANTI ELETTRICI
GALVANIZED STEEL CABLETRAY WITH
COVER (IP4X)
- ELECTRICAL SYSTEMS
TERMOSTRISCIA ELETTRICA
ELECTRICAL RADIANT STRIP
TERMOSTRISCIA ELETTRICA
ELECTRICAL RADIANT STRIP
TERMOSTRISCIA ELETTRICA
ELECTRICAL RADIANT STRIP
TUBAZIONE ACCIAIO ZINCATO (IP67)
GALVANIZED STEEL CONDUIT (IP67)
TUBAZIONE ACCIAIO ZINCATO (IP67)
GALVANIZED STEEL CONDUIT (IP67)
TUBAZIONE ACCIAIO ZINCATO (IP67)
GALVANIZED STEEL CONDUIT (IP67)
PLAFONIERE ILLUMINAZIONE A
PARETE, INCLINAZIONE 45° (IP65)
WALL MOUNTED LIGHTING FIXTURES,
45° TILT (IP65)
TUBAZIONE ACCIAIO
ZINCATO (IP67)
GALVANIZED STEEL
CONDUIT (IP67)
GUAINA METALLICA RIVESTITA IN PVC (IP67)
METAL SHEATH COVERED WITH PVC (IP67)
GUAINA METALLICA RIVESTITA IN PVC (IP67)
METAL SHEATH COVERED WITH PVC (IP67)
GUAINA METALLICA RIVESTITA IN PVC (IP67)
METAL SHEATH COVERED WITH PVC (IP67)
GUAINA METALLICA RIVESTITA IN PVC (IP67)
METAL SHEATH COVERED WITH PVC (IP67)
GUAINA METALLICA RIVESTITA IN
PVC (IP67)
METAL SHEATH COVERED WITH PVC (IP67)
PLAFONIERE ILLUMINAZIONE A
PARETE, INCLINAZIONE 45° (IP65)
WALL MOUNTED LIGHTING FIXTURES,
45° TILT (IP65)
STAFFAGGIO IN ACCORDO CON LE
NORME ANTISISMICHE
BRACKET IN ACCORDANCE WITH
SEISMIC NORMS
PROIETTORE ESTERNO
EXTERNAL FLOODLIGHTING
SCATOLA DERIVAZIONE ESTERNA
IN ACCIAIO ZINCATO(IP67)
EXTERNAL STEEL GALVANIZED
JUNCTION BOX (IP67)
S-502
S-502
S-502
S-502
PULSANTI ALLARME INCENDIO E
FORCE PROTECTION
FIRE ALARM AND FORCE PROTECTION
PUSHBUTTONS
ALTOPARLANTE IMPIANTO NOTIFICA ALLARMI
SPEAKER OF MASS NOTIFICATION SYSTEM
ALTOPARLANTE IMPIANTO NOTIFICA ALLARMI
SPEAKER OF MASS NOTIFICATION SYSTEM
ALTOPARLANTE IMPIANTO
NOTIFICA ALLARMI
SPEAKER OF MASS
NOTIFICATION SYSTEM
LOC
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
N
M
L
I
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
N
M
L
I
H
G
F
E
D
C
B
A
FeR RB
E-302
PROJECT CONDITION: ELECTRICAL SYSTEMS, SECTION D
CONDIZIONE DI PROGETTO: IMPIANTI ELETTRICI, SEZIONE D
PROJECT NUMBER
CHECKED BYENGINEERED BYDRAWN BY
BP
DATE SHEET
SYMBOL DESCRIPTION OF REVISION DRAWN DATE APPROVAL
FINAL SUBMISSION
OF SCALE
DMC PWO
U.S. Army Garrison Italy, APO AE 09613
GENERAL REPAIR BUILDING 703
MARCH 2017 AS SHOWN
F
S B l d g
E
E
E
E
E d w g
AICE
NOTE: / NOTA:
1.00
1:25
0' 2.5'
0 0.50
5' ft7.5'
2.001.50 2.50 m
ELECTRICAL SYSTEMS INSTALLATION DETAIL: SECTION "E" / DETTAGLIO INSTALLAZIONE IMPIANTI ELETTRICI: SEZIONE "E"
SCALE / SCALA
EL101 - EP101
E
1:25
NOTES
NOTE
1-
GLI IMPIANTI ELETTRICI RIPORTATI NELLE SEZIONI SONO DA RITENERSI SOLO A SCOPO INDICATIVO PER LA RISPETTIVA
REALIZZAZIONE.
THE ELECTRICAL SYSTEMS DRAWN IN SECTION ARE TO BE CONSIDERED AS GUIDELINES ONLY FOR THEIR REALIZATION.
TUBAZIONE ACCIAIO
ZINCATO (IP67)
GALVANIZED STEEL
CONDUIT (IP67)
TUBAZIONE ACCIAIO
ZINCATO (IP67)
GALVANIZED STEEL
CONDUIT (IP67)
TUBAZIONE ACCIAIO
ZINCATO (IP67)
GALVANIZED STEEL
CONDUIT (IP67)
PLAFONIERE ILLUMINAZIONE SOSPESE (IP65)
SUSPENDED LIGHTING FIXTURES (IP65)
PLAFONIERA DI EMERGENZA
EMERGENCY LIGHTING FIXTURE
PLAFONIERE ILLUMINAZIONE SOSPESE (IP65)
SUSPENDED LIGHTING FIXTURES (IP65)
PLAFONIERA DI EMERGENZA
EMERGENCY LIGHTING FIXTURE
PLAFONIERE ILLUMINAZIONE SOSPESE (IP65)
SUSPENDED LIGHTING FIXTURES (IP65)
PLAFONIERA DI EMERGENZA
EMERGENCY LIGHTING FIXTURE
PLAFONIERE ILLUMINAZIONE SOSPESE (IP65)
SUSPENDED LIGHTING FIXTURES (IP65)
PLAFONIERA DI EMERGENZA
EMERGENCY LIGHTING FIXTURE
TERMOSTRISCIA ELETTRICA
ELECTRICAL RADIANT STRIP
TERMOSTRISCIA ELETTRICA
ELECTRICAL RADIANT STRIP
TERMOSTRISCIA ELETTRICA
ELECTRICAL RADIANT STRIP
TERMOSTRISCIA ELETTRICA
ELECTRICAL RADIANT STRIP
GRUPPO PRESE CEE (IP66)
CEE OUTLETS BATTERY (IP66)
TUBAZIONE ACCIAIO
ZINCATO (IP67)
GALVANIZED STEEL
CONDUIT (IP67)
GRUPPO PRESE CEE (IP66)
CEE OUTLETS BATTERY (IP66)
GRUPPO PRESE CEE (IP66)
CEE OUTLETS BATTERY (IP66)
GRUPPO PRESE CEE (IP66)
CEE OUTLETS BATTERY (IP66)
CANALE PORTACAVI IN ACCIAIO
ZINCATO CON COPERCHIO
(IP4X)INSTALLATO DIETRO LA TRAVE:
- IMPIANTI ELETTRICI
GALVANIZED STEEL CABLETRAY WITH
COVER (IP4X), REAR BEAM MOUNTED:
- ELECTRICAL SYSTEMS
CANALE PORTACAVI IN ACCIAIO
ZINCATO CON COPERCHIO
(IP4X)INSTALLATO DIETRO LA TRAVE:
- IMPIANTI ELETTRICI
GALVANIZED STEEL CABLETRAY WITH
COVER (IP4X), REAR BEAM MOUNTED:
- ELECTRICAL SYSTEMS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
N
M
L
I
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
N
M
L
I
H
G
F
E
D
C
B
A
FeR RB
E-303
PROJECT CONDITION: ELECTRICAL SYSTEMS, SECTION E
CONDIZIONE DI PROGETTO: IMPIANTI ELETTRICI, SEZIONE E
PROJECT NUMBER
CHECKED BYENGINEERED BYDRAWN BY
BP
DATE SHEET
SYMBOL DESCRIPTION OF REVISION DRAWN DATE APPROVAL
FINAL SUBMISSION
OF SCALE
DMC PWO
U.S. Army Garrison Italy, APO AE 09613
GENERAL REPAIR BUILDING 703
MARCH 2017 AS SHOWN
F
S B l d g
E
E
E
E
E d w g
AICE
NOTE: / NOTA:
1.00
1:25
0' 2.5'
0 0.50
5' ft7.5'
2.001.50 2.50 m
ELECTRICAL SYSTEMS INSTALLATION DETAIL: SECTION "F" / DETTAGLIO INSTALLAZIONE IMPIANTI ELETTRICI: SEZIONE "F"
SCALE / SCALA
EL101 - EP101
F
1:25
NOTES
NOTE
1-
GLI IMPIANTI ELETTRICI RIPORTATI NELLE SEZIONI SONO DA RITENERSI SOLO A SCOPO INDICATIVO PER LA RISPETTIVA
REALIZZAZIONE.
THE ELECTRICAL SYSTEMS DRAWN IN SECTION ARE TO BE CONSIDERED AS GUIDELINES ONLY FOR THEIR REALIZATION.
PLAFONIERE ILLUMINAZIONE SU
STAFFE, INCLINAZIONE 45° (IP65)
LIGHTING FIXTURES ON SUPPORTS, 45°
TILT (IP65)
CENTRALINA COMANDO
MOTORIZZAZIONE SERRANDA
MOTOR CONTROL PANEL
AUTOMATIC DOOR
GRUPPO PRESE CEE (IP66)
CEE OUTLETS BATTERY (IP66)
PLAFONIERE ILLUMINAZIONE SU
STAFFE, INCLINAZIONE 45° (IP65)
LIGHTING FIXTURES ON SUPPORTS, 45°
TILT (IP65)
PLAFONIERE ILLUMINAZIONE SU
STAFFE, INCLINAZIONE 45° (IP65)
LIGHTING FIXTURES ON SUPPORTS, 45°
TILT (IP65)
PLAFONIERE ILLUMINAZIONE A
PARETE, INCLINAZIONE 45° (IP65)
WALL MOUNTED LIGHTING FIXTURES,
45° TILT (IP65)
PLAFONIERE ILLUMINAZIONE A
PARETE, INCLINAZIONE 45° (IP65)
WALL MOUNTED LIGHTING FIXTURES,
45° TILT (IP65)
CENTRALINA COMANDO
MOTORIZZAZIONE SERRANDA
MOTOR CONTROL PANEL
AUTOMATIC DOOR
CENTRALINA COMANDO
MOTORIZZAZIONE SERRANDA
MOTOR CONTROL PANEL
AUTOMATIC DOOR
CENTRALINA COMANDO
MOTORIZZAZIONE SERRANDA
MOTOR CONTROL PANEL
AUTOMATIC DOOR
GRUPPO PRESE CEE (IP66)
CEE OUTLETS BATTERY (IP66)
TUBAZIONE ACCIAIO
ZINCATO (IP67)
GALVANIZED STEEL
CONDUIT (IP67)
TUBAZIONE ACCIAIO
ZINCATO (IP67)
GALVANIZED STEEL
CONDUIT (IP67)
SEGNALATORI OTTICI IMPIANTI
ANTINCENDIO E NOTIFICA ALLARMI
VISUAL ALARM DEVICES OF FIRE ALARM
AND MASS NOTIFICATION SYSTEMS
SEGNALATORI OTTICI IMPIANTI
ANTINCENDIO E NOTIFICA ALLARMI
VISUAL ALARM DEVICES OF FIRE ALARM
AND MASS NOTIFICATION SYSTEMS
PULSANTI ALLARME INCENDIO E
FORCE PROTECTION
FIRE ALARM AND FORCE PROTECTION
PUSHBUTTONS
ALTOPARLANTE IMPIANTO NOTIFICA
ALLARMI
SPEAKER OF MASS NOTIFICATION
SYSTEM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
N
M
L
I
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
N
M
L
I
H
G
F
E
D
C
B
A
FeR RB
E-304
PROJECT CONDITION: ELECTRICAL SYSTEMS, SECTION F
CONDIZIONE DI PROGETTO: IMPIANTI ELETTRICI, SEZIONE F
PROJECT NUMBER
CHECKED BYENGINEERED BYDRAWN BY
BP
DATE SHEET
SYMBOL DESCRIPTION OF REVISION DRAWN DATE APPROVAL
FINAL SUBMISSION
OF SCALE
DMC PWO
U.S. Army Garrison Italy, APO AE 09613
GENERAL REPAIR BUILDING 703
MARCH 2017 AS SHOWN
F
S B l d g
E
E
E
E
E d w g
AICE
NOTE: / NOTA:
1.00
1:25
0' 2.5'
0 0.50
5' ft7.5'
2.001.50 2.50 m
ELECTRICAL SYSTEMS INSTALLATION DETAIL: SECTION "G" / DETTAGLIO INSTALLAZIONE IMPIANTI ELETTRICI: SEZIONE "G"
SCALE / SCALA
EL101 - EP101
G
1:25
NOTES
NOTE
1-
GLI IMPIANTI ELETTRICI RIPORTATI NELLE SEZIONI SONO DA RITENERSI SOLO A SCOPO INDICATIVO PER LA RISPETTIVA
REALIZZAZIONE.
THE ELECTRICAL SYSTEMS DRAWN IN SECTION ARE TO BE CONSIDERED AS GUIDELINES ONLY FOR THEIR REALIZATION.
GRUPPO PRESE CEE (IP66)
CEE OUTLETS BATTERY (IP66)
CANALE PORTACAVI IN ACCIAIO
ZINCATO CON COPERCHIO (IP4X)
- IMPIANTI ELETTRICI
GALVANIZED STEEL CABLETRAY WITH
COVER (IP4X)
- ELECTRICAL…