Troopcamp Addendum 3.doc
DOC document 42 KB Posted
- Attached to
- RECOVERY--Y--Replace Troop Training Quarters Federal contract opportunity
- Solicitation number
- W912KC-09-B-0009
About this file
Revised Specifications Drawings
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| SK-A4.pdf | ||
| SK-A3.pdf | ||
| 08410 Metal Framed Storefronts.pdf | ||
| SK-A5.pdf | ||
| SK-P1.pdf | ||
| SK-C2.pdf | ||
| E102 ADD 2.pdf | ||
| 16711 - Telecommunications.pdf | ||
| E001 ADD 2.pdf | ||
| SK-A2.pdf | ||
| SK-A1.pdf | ||
| E602 ADD 2.pdf | ||
| SK-C3.pdf | ||
| E108 ADD 2.pdf | ||
| 02820 - Aluminum Louver Fencing.pdf | ||
| 04720 - Cast Stone.pdf | ||
| E604 ADD 2.pdf | ||
| SK-C1.pdf | ||
| E107 ADD 2.pdf | ||
| Troopcamp Addendum 2.doc | DOC document | |
| E601 ADD 2.pdf | ||
| 09900 Paints and Coatings.pdf | ||
| S102.pdf | ||
| S302.pdf | ||
| Troopcamp Addendum 1.pdf | ||
| 05520 Handrails and Railing.pdf | ||
| S101.pdf | ||
| 02225 Building Demolition.pdf | ||
| Replace Troop Training Quarters.pdf | ||
| Troop Training Spec Vol 2.pdf | ||
| Troop Training Spec Vol 1.pdf |
Show all 31
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REPLACE TROOP TRAINING QUARTERS
193d Regional Support Group Pennsylvania Air National Guard
Ft. Indiantown Gap, Annville, Pennsylvania
Project No. LKLW959714
ADDENDUM #3
REVISIONS TO SPECIFICATIONS
· 08410 – METAL-FRAMED STOREFRONT
1) REPLACE Section 08410 with the attached Section 08410 in its entirety.
· 16711 – TELECOMMUNICATIONS
1) REVISE Paragraph 2.01 to read: TELEPHONE BACKBOARD (all communication roomS 104 and 202 walls)
· 13900 – FIRE SUPPRESSION
1) Delete Paragraphs 4. and 7. under Article 1.01 Paragraph A.
2) Delete Article 2.05 CLEAN AGENT FIRE EXTINGUISHING SYSTEM and the associated sub-paragraphs
3) Delete Article 2.06 CLEAN AGENT SYSTEM CONTROLS AND ASSOCIATED DEVISES and the associated sub-paragraphs
4) Delete Article 2.07 PREACTION – SINGLE INTERLOCK SYSTEM and the associated sub-paragraphs
· 15150 – SANITARY WASTE AND VENT PIPING
1) Add Paragraph D. under Article 2.05 FLOOR DRAINS “D. Floor Drain (FD-3): Outlet size 80 mm (3-inch); Cast iron, two piece body with 150 mm (6-inch) diameter adjustable stainless steel strainer, medium duty, invertible membrane flashing clamp and adjustable collar with seepage holes, trap primer tap; ZS-415-P.”
REVISIONS TO DRAWINGS
· A301 – BUILDING AND WALL SECTIONS
1) REVISE Wall Section 2 with revised partial Wall Section 2 as shown on SK-A3.
· A401 – ENLARGED STAIR AND ELEVATOR PLANS AND DETAILS
1) REPLACE Section 8 with Section 8 as shown on SK-A4.
· A602 – DOOR AND WINDOW DETAILS
1) REPLACE Detail 28 with Detail 28 as shown on SK-A5.
· P601 – PLUMBING SCHEDULES
1) REPLACE Drain and Shower Base Schedule with Drain and Shower Base Schedule shown on SK-P1
2) REVISE Plumbing Fixture Schedule to indicate DELETED for fixture SYMBOL P-4.