Troop Training Spec Vol 2.pdf
PDF 5 MB Posted
- Attached to
- RECOVERY--Y--Replace Troop Training Quarters Federal contract opportunity
- Solicitation number
- W912KC-09-B-0009
About this file
Replace Troop Training Quarters Specifications 2
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Troopcamp Addendum 3.doc | DOC document | |
| SK-A4.pdf | ||
| SK-A3.pdf | ||
| SK-P1.pdf | ||
| 08410 Metal Framed Storefronts.pdf | ||
| SK-A5.pdf | ||
| SK-C2.pdf | ||
| E102 ADD 2.pdf | ||
| 16711 - Telecommunications.pdf | ||
| E001 ADD 2.pdf | ||
| Troopcamp Addendum 2.doc | DOC document | |
| E601 ADD 2.pdf | ||
| SK-A2.pdf | ||
| SK-A1.pdf | ||
| E602 ADD 2.pdf | ||
| SK-C3.pdf | ||
| E108 ADD 2.pdf | ||
| 02820 - Aluminum Louver Fencing.pdf | ||
| 04720 - Cast Stone.pdf | ||
| E604 ADD 2.pdf | ||
| SK-C1.pdf | ||
| E107 ADD 2.pdf | ||
| 09900 Paints and Coatings.pdf | ||
| S102.pdf | ||
| S302.pdf | ||
| 05520 Handrails and Railing.pdf | ||
| S101.pdf | ||
| 02225 Building Demolition.pdf | ||
| Troopcamp Addendum 1.pdf | ||
| Replace Troop Training Quarters.pdf | ||
| Troop Training Spec Vol 1.pdf |
Show all 31
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BID DOCUMENTS
SPECIFICATIONS – VOLUME II
193d REGIONAL SUPPORT GROUP
PENNSYLVANIA AIR NATIONAL GUARD
FT INDIANTOWN GAP
ANNVILLE , PENNSYLVANIA
REPLACE TROOP
TRAINING QUARTERS
Project No. LKLW959714
AUGUST 14, 2009
193d REGIONAL SUPPORT GROUP PROJECT NO. LKLW959714
REPLACE TROOP TRAINING QUARTERS TABLE OF CONTENTS - 1
TABLE OF CONTENTS
NOTE: This Project Manual is arranged in the nationally recognized Construction Specification
Institute Format (CSI). However, only the applicable Sections of certain Divisions are included which results in the section numbering not being consecutive.
VOLUME I
DIVISION 01 – GENERAL REQUIREMENTS
01000 – REQUIREMENTS OF THE PENNSYLVANIA AIR
NATIONAL GUARD 01000-1
01030 – METRIC MEASUREMENTS 01030-1
01039 – COORDINATION AND MEETINGS 01039-1
01050 – FIELD ENGINEERING 01050-1
01060 – SAFETY POLICIES AND PROCEDURES 01060-1
01100 – SUMMARY 01100-1
01300 – ADMINISTRATIVE REQUIREMENTS 01300-1
01325 – CONSTRUCTION PROGRESS SCHEDULE 01325-1
01354 – LEED CREDIT SUMMARY 01354-1
01355 – LEED CERTIFICATION PROCEDURES 01355-1
01356 – LEED SUBMITTAL FORMS 01356-1
01357 – LEED MATERIAL COST SUMMARY FORM 01357-1
01358 – LEED WOOD CONTAINING PRODUCT LIST 01358-1
01359 – LEED METAL CONTAINING PRODUCT LIST 01359-1
01360 – LEED NEW PRODUCT CONTENT FORM 01360-1
01361 – LEED NEW PRODUCT SOURCE FORM 01361-1
01363 – LEED PROHIBITED CONTENT INSTALLER
CERTIFICATION 01363-1
01400 – QUALITY REQUIREMENTS 01400-1
01410 – ENVIRONMENTAL PROTECTION 01410-1
01500 –TEMPORARY FACILITIES AND CONTROLS 01500-1
01510 – TEMPORARY UTILITIES 01510-1
01524 – CONSTRUCTION WASTE MANAGEMENT 01524-1
01525 – FIELD OFFICES 01525-1
01565 – SECURITY MEASURES 01565-1
01600 – PRODUCT REQUIREMENTS 01600-1
01616 – VOLITILE ORGANIC COMPOUND (VOC)
CONTENT RESTRICTIONS 01616-1
01617 – ACCESSORY MATERIAL VOC CONTENT
CERTIFICATION FORM 01617-1
01640 – MANUFACTURER’S SERVICES 01640-1
01650 – STARTING OF SYSTEMS 01650-1
01700 –EXECUTION REQUIREMENTS 01700-1
01720 – PROJECT RECORD DOCUMENTS 01720-1
01730 – OPERATION AND MAINTENANCE DATA 01730-1
01732 – WASTE MANAGEMENT 01732-1
01734 – INDOOR AIR QUALITY 01734-1
REPLACE TROOP TRAINING QUARTERS TABLE OF CONTENTS - 2
01740 – WARRANTIES 01740-1
01770 – PROJECT CLOSEOUT 01770-1
01780 – CLOSEOUT SUBMITTALS 01780-1
01810 – COMMISSIONING 01810-1
DIVISION 02 – SITE WORK
02010 – SUBSURFACE EXPLORATION 02010-1
02200 – DEMOLITION 02200-1
02230 – SITE CLEARING 02230-1
02300 – EARTHWORK (UNCLASSIFIED) 02300-1
02310 – GRADING 02310-1
02312 – FINISH GRADING 02312-1
02317 – TRENCHING FOR SITE UTILITIES 02317-1
02370 – EROSION AND SEDIMENT CONTROL 02370-1
02501 – SUPERPAVE ASPHALT MIX, HMA PAVING AND
SURFACING 02501-1
02530 - SANITARY SEWER MANHOLES, FRAMES, AND COVERS 02530-1
02582 – UNDERGROUND DUCTS AND MANHOLES 02582-1
02630 – STORM DRAINAGE 02630-1
02700 – PIPED UTILITIES 02700-1
02772 – CEMENT CONCRETE CURBS 02772-1
02775 – SIDEWALKS 02775-1
02821 – CHAIN LINK FENCES AND GATES 02821-1
02850 – PREFABRICATED STEEL BRIDGE 02850-1
02875 – SITE AMENITIES 02875-1
02900 – PLANTING 02900-1
02919 – TOPSOIL 02919-1
02925 – SEEDING AND SOIL SUPPLEMENTS 02925-1
DIVISION 03 - CONCRETE
03100 – CONCRETE FORMS 03100-1
03130 – PERMANENT INSULATING CONCRETE
FORMWORK SYSTEMS 03130-1
03200 – CONCRETE REINFORCEMENT 03200-1
03300 – CAST-IN-PLACE CONCRETE 03300-1
03410 – HOLLOWCORE PRECAST CONCRETE 03410-1
03600 – GROUT 03600-1
DIVISION 04 – MASONRY
04065 – MORTAR AND MASONRY GROUT 04065-1
04810 – UNIT MASONRY ASSEMBLIES 04810-1
DIVISION 05 – METALS
05120 – STRUCTURAL STEEL 05120-1
05310 – STEEL DECK 05310-1
05425 – PRE-ENGINEERED, PREFABRICATED LIGHT GAUGE
REPLACE TROOP TRAINING QUARTERS TABLE OF CONTENTS - 3
STEEL ROOF TRUSSES 05425-1
05500 – METAL FABRICATIONS 05500-1
05511 – METAL STAIRS 05511-1
VOLUME II
DIVISION 06 - WOOD AND PLASTICS
06100 – ROUGH CARPENTRY 06100-1
06200 – FINISH CARPENTRY 06200-1
06410 – CUSTOM CABINETS 06410-1
06415 – COUNTERTOPS 06415-1
DIVISION 07 - THERMAL AND MOISTURE PROTECTION
07212 – BOARD AND BATT INSULATION 07212-1
07214 – FOAMED-IN-PLACE INSULATION 07214-1
07260 – WEATHER BARRIERS 07620-1
07311 – ASPHALT SHINGLES 07311-1
07411 – STANDING SEAM ROOF PANELS 07411-1
07620 – SHEET METAL FLASHING AND TRIM 07620-1
07710 – MANUFACTURED ROOF SPECIALTIES 07710-1
07840 – FIRESTOPPING 07840-1
07900 - JOINT SEALERS 07900-1
DIVISION 08 - DOORS AND WINDOWS
08110 - STEEL DOORS AND FRAMES 08110-1
08211 – FLUSH WOOD DOORS 08211-1
08334 – COILING COUNTER DOORS 08334-1
08410 – METAL-FRAMED STOREFRONTS 08410-1
08710 - DOOR HARDWARE 08710-1
08800 – GLAZING 08800-1
DIVISION 09 - FINISHES
09111 – NON-LOADBEARING METAL FRAMING 09111-1
09212 – SPRAY-ON ACOUSTIC FINISH 09212-1
09260 – GYPSUM BOARD ASSEMBLIES 09260-1
09300 – TILE 09300-1
09511 – SUSPENDED ACOUSTICAL CEILINGS 09511-1
09641 – HARDWOOD FLOORING 09641-1
09650 – RESILIENT FLOORING 09650-1
09685 – CARPET TILE 09685-1
09900 - PAINTS AND COATINGS 09900-1
DIVISION 10 - SPECIALTIES
10100 – VISUAL DISPLAY BOARDS 10100-1
10210 – WALL LOUVERS 10210-1
10400 – IDENTIFYING DEVICES 10400-1
REPLACE TROOP TRAINING QUARTERS TABLE OF CONTENTS - 4
10523 – FIRE EXTINGUISHERS, CABINETS, AND ACCESSORIES 10523-1
10673 – WALL MOUNTED STANDARDS AND SHELVING 10673-1
10800 – TOILET, BATH, AND LAUNDRY ACCESSORIES 10800-1
DIVISION 11 – EQUIPMENT
11457 – MONITOR MOUNTS 11457-1
DIVISION 12 – FURNISHINGS
12485 – FOOT GRILLES, MATS, AND FRAMES 12485-1
12492 – HORIZONTAL LOUVER BLINDS 12492-1
DIVISION 13 – SPECIAL CONSTRUCTION
13100 – LIGHTNING PROTECTION 13100-1
13852 – FIRE ALARM / MASS NOTIFICATION SYSTEM 13852 -1
13900 – FIRE SUPPRESSION 13900-1
13910 – BASIC FIRE SUPPRESSION MATERIALS AND METHODS 13910-1
DIVISION 14 – CONVEYING SYSTEMS
14210 – ELECTRIC TRACTION ELEVATORS 14210-1
DIVISION 15 - MECHANICAL
15050 – BASIC MECHANICAL MATERIALS AND METHODS 15050-1
15060 – SUPPORTS, ANCHORS, AND SEALS 15060-1
15075 – BUILDING MECHANICAL IDENTIFICATION 15075-1
15080 – MECHANICAL INSULATION 15080-1
15120 – HYDRONIC PIPING SPECIALTIES 15120-1
15130 – HYDRONIC PUMPS 15130-1
15140 – DOMESTIC WATER PIPING 15140-1
15150 – SANITARY WASTE AND VENT PIPING 15150-1
15180 – HYDRONIC PIPING 15180-1
15185 – HVAC WATER TREATMENT 15185-1
15195 – GAS PIPING 15195-1
15232 – REFRIGERANT PIPING 15232-1
15400 – PLUMBING FIXTURES AND EQUIPMENT 15400-1
15510 – HEATING BOILERS AND ACCESSORIES 15510-1
15543 – ELECTRIC HEATERS 15543-1
15640 – PACKAGED COOLING TOWERS 15640-1
15730 – UNITARY AIR CONDITIONING EQUIPMENT 15730-1
15731 – DUCTLESS SPLIT-SYSTEMS 15731-1
15735 – PACKAGED AIR CONDITIONING UNITS 15735-1
15800 – AIR DISTRIBUTION 15800-1
15830 – FANS 15830-1
15910 – DIRECT DIGITAL CONTROLS 15910-1
15940 – SEQUENCE OF OPERATION 15940-1
15950 – TESTING, ADJUSTING AND BALANCING 15950-1
15990 – MECHANICAL COMMISSIONING 15990-1
REPLACE TROOP TRAINING QUARTERS TABLE OF CONTENTS - 5
DIVISION 16 – ELECTRICAL
16050 – BASIC ELECTRICAL MATERIALS AND METHODS 16050-1
16060 – ELECTRICAL GROUNDING AND BONDING 16060-1
16070 – ELECTRICAL HANGERS AND SUPPORTS 16070-1
16075 – ELECTRICAL IDENTIFICATION 16075-1
16080 – ELECTRICAL TESTING 16080-1
16121 – MEDIUM VOLTAGE WIRE, CABLE AND ACCESSORIES 16121-1
16122 – LOW VOLTAGE WIRE, CABLE AND ACCESSORIES 16122-1
16131 – CONDUIT AND TUBING 16138-1
16134 – CABLE TRAYS AND FITTINGS 16134-1
16138 – BOXES 16138-1
16140 – WIRING DEVICES 16140-1
16150 – WIRING CONNECTIONS 16150-1
16210 – ELECTRIC UTILITY SERVICE 16210-1
16271 – PAD-MOUNTED TRANSFORMERS 16271-1
16285 – TRANSIENT VOLTAGE SURGE SUPPRESSORS 16285-1
16411 – LOW-VOLTAGE ENCLOSED CIRCUIT BREAKERS 16411-1
16412 – LOW-VOLTAGE ENCLOSED SWITCHES 16412-1
16413 – ENCLOSED TRANSFER SWITCHES 16413-1
16443 – PANELBOARDS 16443-1
16500 – LIGHTING 16500-1
16711 – TELECOMMUNICATIONS 16711-1
16821 – PUBLIC ADDRESS 16821-1
16990 – ELECTRICAL COMMISSIONING 16990-1
APPENDICES
APPENDIX 1 – COLOR SCHEMES
THIS PAGE INTENTIONALLY LEFT BLANK
REPLACE TROOP TRAINING QUARTERS 06100 - 1
SECTION 06100
ROUGH CARPENTRY
PART 1 GENERAL
1.01 SUMMARY
A. Section Includes:
1. Underlayment.
2. Preservative treated wood materials.
3. Fire retardant treated wood materials.
4. Miscellaneous framing and sheathing.
5. Communications and electrical room mounting boards.
6. Concealed wood blocking, nailers, and supports.
7. Miscellaneous wood nailers, furring, and grounds.
B. Related Sections:
1. Section 01355 - LEED Certification Procedures.
2. Section 01363 - LEED Prohibited Content Installer Certification.
3. Section 01616 - Volatile Organic Compound (VOC) Content Restrictions.
1.02 REFERENCE STANDARDS
A. ALSC - Accredited Testing Agencies; American Lumber Standards Committee; 2004
B. ASTM A 153/A 153M - Standard Specification for Zinc Coating (Hot-Dip) on Iron and
Steel Hardware; 2005.
C. ASTM A 123 - Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel
Products.
D. ASTM A 153 - Specification for Zinc Coating (Hot-Dip) on Iron and Steel Hardware.
E. ASTM E 84 - Standard Test Method for Surface Burning Characteristics of Building
Materials; 2008.
F. AWPA C9 - Plywood -- Preservative Treatment by Pressure Processes; American Wood
Protection Association; 2003.
G. AWPA C20 - Structural Lumber -- Fire Retardant Treatment by Pressure Processes;
American Wood-Protection Association; 2003.
H. AWPA C27 - Plywood -- Fire-Retardant Treatment by Pressure Processes; American
Wood-Protection Association; 2002.
I. AWPA U1 - Use Category System: User Specification for Treated Wood; American
Wood-Protection Association; 2007.
J. PS 1 - Structural Plywood; 2007.
K. PS 20 - American Softwood Lumber Standard; National Institute of Standards and
Technology (Department of Commerce); 2005.
L. SPIB (GR) - Grading Rules; Southern Pine Inspection Bureau, Inc.; 2002.
REPLACE TROOP TRAINING QUARTERS 06100 - 2
1.03 SYSTEM DESCRIPTION
A. LEED Requirements:
1. Provide wood based materials and products which are certified in accordance with the Forest Stewardship Council's (FSC) Principles and Criteria for wood building components.
2. Products supplied as part of this section shall contain no added urea-formaldehyde resins. Laminated adhesives used to fabricate on-site and shop-applied composite wood assemblies shall contain no urea-formaldehyde resins.
3. Give preference to products extracted/harvested/recovered and manufactured within
800 km (500 miles) of the project site.
1.04 SUBMITTALS
A. Product Data: Provide technical data on wood preservative materials and application instructions.
B. Manufacturer's Certificate: Certify that wood products supplied for rough carpentry meet or exceed specified requirements.
C. LEED Submittals:
1. Submit applicable LEED Submittal Form for each different product made of sustainably harvested wood as well as locally-sourced wood, as specified in Section
01355. Provide Chain-of-Custody (COC) certifications as part of the submission.
2. Submit applicable LEED Submittal Form for each different product showing no urea-formaldehyde resins were used in products of this section as specified in
Section 01355 and 01363.
3. Submit applicable LEED Submittal Form for each different product extracted/harvested/recovered and manufactured within 800 km (500 miles) of the project site.
1.05 QUALITY ASSURANCE
A. Lumber: Comply with PS 20 and approved grading rules and inspection agencies.
1. Lumber of other species or grades, or graded by other agencies, is acceptable provided structural and appearance characteristics are equivalent to or better than products specified.
1.06 DELIVERY, STORAGE, AND HANDLING
A. General: Cover wood products to protect against moisture. Support stacked products to prevent deformation and to allow air circulation.
B. Fire Retardant Treated Wood: Prevent exposure to precipitation during shipping, storage, or installation.
PART 2 PRODUCTS
2.01 GENERAL REQUIREMENTS
A. Dimension Lumber: Comply with PS 20 and requirements of specified grading agencies.
1. If no species is specified, provide any species graded by the agency specified; if no
REPLACE TROOP TRAINING QUARTERS 06100 - 3
grading agency is specified, provide lumber graded by any grading agency meeting the specified requirements.
2. Grading Agency: Any grading agency whose rules are approved by the Board of
Review, American Lumber Standard Committee (www.alsc.org) and who provides grading service for the species and grade specified; provide lumber stamped with grade mark unless otherwise indicated.
B. Lumber fabricated from old growth timber is not permitted.
C. Provide sustainably harvested wood; see Section 01600 for requirements.
D. Provide products containing no urea-formaldehyde resins, including laminating adhesives used on site.
E. Provide wood harvested within a 804 km (500 mile) radius of the project site; see
Section 01600 for requirements for locally-sourced products.
2.02 DIMENSION LUMBER FOR CONCEALED APPLICATIONS
A. Grading Agency: Southern Pine Inspection Bureau, Inc. (SPIB).
B. Sizes: Nominal sizes as indicated on drawings, S4S.
C. Moisture Content: S-dry or MC19.
D. Miscellaneous Framing, Blocking, Nailers, Grounds, and Furring:
1. Lumber: S4S, No. 2 or Standard Grade.
2. Boards: Standard or No. 3.
E. Miscellaneous Blocking, Furring, and Nailers:
1. Lumber: S4S, No. 1 or Construction Grade.
2. Boards: Standard or No. 3.
2.03 CONSTRUCTION PANELS
A. Communications and Electrical Room Mounting Boards: PS 1 A-D plywood, or medium density fiberboard; 19 mm (3/4 inch) thick; flame spread index of 25 or less, smoke developed index of 450 or less, when tested in accordance with ASTM E 84.
B. Other Applications:
1. Concealed Plywood: PS 1, B-B Plugged, exterior grade.
2. Exposed Plywood: PS 1, A-B, interior grade.
3. Other Locations: PS 1, C-D Plugged or better.
4. Electrical Component Mounting: APA rated sheathing.
2.04 ACCESSORIES
A. Fasteners and Anchors:
1. Fasteners: Hot-dipped galvanized steel per ASTM A 153/A 153M (per ASTM
A153) steel for high humidity and treated wood locations, unfinished steel elsewhere.
2.05 FACTORY WOOD TREATMENT
A. Treated Lumber and Plywood: Comply with requirements of AWPA U1 - Use
REPLACE TROOP TRAINING QUARTERS 06100 - 4
Category System for wood treatments determined by use categories, expected service conditions, and specific applications.
1. Fire-Retardant Treated Wood: Mark each piece of wood with producer's stamp indicating compliance with specified requirements.
B. Fire Retardant Treatment:
1. Interior Type A: AWPA Use Category UCFA, Commodity Specification H
(Treatment C20 for lumber and C27 for plywood), low temperature (low hygroscopic) type, chemically treated and pressure impregnated; capable of providing a maximum flame spread rating of 25 when tested in accordance with
ASTM E 84, with no evidence of significant combustion when test is extended for an additional 20 minutes.
a. Kiln dry wood after treatment to a maximum moisture content of 19 percent for lumber and 15 percent for plywood.
b. Treat rough carpentry items as indicated .
c. Do not use treated wood in applications exposed to weather or where the wood may become wet.
C. Preservative Pressure Treatment of Plywood Above Grade: AWPA Use Category UC2 and UC3B, Commodity Specification F (Treatment C9) using waterborne preservative to 4.0 kg/cu m (0.25 lb/cu ft) retention.
1. Kiln dry plywood after treatment to maximum moisture content of 19 percent.
2. Treat plywood in contact with roofing, flashing, or waterproofing.
3. Treat plywood in contact with masonry or concrete.
4. Treat plywood in other locations as indicated.
PART 3 EXECUTION
3.01 PREPARATION
A. Coordinate installation of rough carpentry members specified in other sections.
3.02 INSTALLATION - GENERAL
A. Select material sizes to minimize waste.
B. Reuse scrap to the greatest extent possible; clearly separate scrap for use on site as accessory components, including: shims, bracing, and blocking.
C. Where treated wood is used on interior, provide temporary ventilation during and immediately after installation sufficient to remove indoor air contaminants.
3.03 BLOCKING, NAILERS, AND SUPPORTS
A. Provide framing and blocking members as indicated or as required to support finishes, fixtures, specialty items, and trim.
B. In walls, provide blocking attached to studs as backing and support for wall-mounted items, unless item can be securely fastened to two or more studs or other method of support is explicitly indicated.
C. Specifically, provide the following non-structural framing and blocking:
1. Cabinets and shelf supports.
REPLACE TROOP TRAINING QUARTERS 06100 - 5
2. Wall brackets.
3. Handrails.
4. Grab bars.
5. Towel and bath accessories.
6. Wall-mounted door stops.
7. Chalkboards and marker boards.
8. Joints of rigid wall coverings that occur between studs.
3.04 INSTALLATION OF CONSTRUCTION PANELS
A. Communications and Electrical Room Mounting Boards: Secure with screws to studs with edges over firm bearing; space fasteners at maximum 610 mm (24 inches) on center on all edges and into studs in field of board.
1. At fire-rated walls, install board over wall board indicated as part of the fire-rated assembly.
2. Where boards are indicated as full floor-to-ceiling height, install with long edge of board parallel to studs.
3. Install adjacent boards without gaps.
3.05 SITE APPLIED WOOD TREATMENT
A. Apply preservative treatment compatible with factory applied treatment at site-sawn cuts, complying with manufacturer's instructions.
B. Allow preservative to dry prior to erecting members.
3.06 TOLERANCES
A. Framing Members: 6 mm (1/4 inch) from true position, maximum.
B. Variation from Plane (Other than Floors): 2 mm/m (1/4 inch in 10 feet) maximum, and
7 mm in 10 m (1/4 inch in 30 feet) maximum.
3.07 CLEANING
A. Waste Disposal: Comply with the requirements of Section 01524.
1. Comply with applicable regulations.
2. Do not burn scrap on project site.
3. Do not burn scraps that have been pressure treated.
4. Do not send materials treated with pentachlorophenol, CCA, or ACA to co-generation facilities or “waste-to-energy” facilities.
B. Prevent sawdust and wood shavings from entering the storm drainage system.
END OF SECTION
REPLACE TROOP TRAINING QUARTERS 06200 - 1
SECTION 06200
FINISH CARPENTRY
1.01 SUMMARY
A. Section Includes:
1. Finish carpentry items.
2. Wood casings and moldings.
B. Related Sections:
1. Section 01616 - Volatile Organic Compound (VOC) Content Restrictions.
2. Section 06100 - Rough Carpentry: Support framing, grounds, and concealed blocking.
3. Section 06410 - Custom Cabinets: Shop fabricated custom cabinet work.
4. Section 09900 - Paints and Coatings: Painting and finishing of finish carpentry items.
1.02 REFERENCE STANDARDS
A. AWI/AWMAC (QSI) - Architectural Woodwork Quality Standards Illustrated;
Architectural Woodwork Institute and Architectural Woodwork Manufacturers
Association of Canada; 2005, 8th Ed., Version 2.0.
1.03 SYSTEM DESCRIPTION
A. LEED Requirements
1. Provide wood based materials and products which are certified in accordance with the Forest Stewardship Council's (FSC) Principles and Criteria for wood building components.
2. Products supplied as part of this section shall contain no added urea-formaldehyde resins. Laminated adhesives used to fabricate on-site and shop-applied composite wood assemblies shall contain no urea-formaldehyde resins.
3. Give preference to products extracted/harvested/recovered and manufactured within
800 km (500 miles) of the project site.
1.04 SUBMITTALS
A. Product Data:
1. Provide instructions for finish hardware.
B. Shop Drawings: Indicate materials, component profiles, fastening methods, jointing details, accessories, to a minimum scale of 1:8 (1-1/2 inch to 1 ft).
C. Samples:
1. Samples: Submit two samples of finish wood, 150x150 mm (6 x 6 inch) in size illustrating wood grain and specified finish.
D. LEED Report:
1. Submit applicable LEED Submittal Form for each different product made of sustainably harvested wood as well as locally-sourced wood, as specified in Section
REPLACE TROOP TRAINING QUARTERS 06200 - 2
01355. Provide Chain-of-Custody (COC) certifications as part of the submission.
2. Submit applicable LEED Submittal Form for each different product showing no urea-formaldehyde resins were used in products of this section as specified in
Section 01355 and 01363
3. Submit applicable LEED Submittal Form for each different product extracted/harvested/recovered and manufactured within 800 km (500 miles) of the project site
1.05 QUALITY ASSURANCE
A. Perform work in accordance with AWI Architectural Woodwork Quality Standards
Illustrated, Custom grade.
1.06 DELIVERY, STORAGE, AND HANDLING
A. Protect work from moisture damage.
1.07 PROJECT CONDITIONS
A. Sequence installation to ensure utility connections are achieved in an orderly and expeditious manner.
B. Coordinate the work with installation of associated and adjacent components.
PART 2 PRODUCTS
2.01 MATERIALS - GENERAL
A. Unless otherwise indicated provide products of quality specified by AWI Architectural
Woodwork Quality Standards Illustrated for Custom grade.
B. Unless otherwise indicated provide products of quality specified by Woodwork Institute
Manual of Millwork for Custom grade.
C. Provide products containing no urea-formaldehyde resins, including laminating adhesives used on site.
2.02 WOOD-BASED COMPONENTS
A. Wood fabricated from old growth timber is not permitted.
B. Provide sustainably harvested wood, certified or labeled as specified in Section 01600.
C. Provide wood harvested within a 805 km (500 mile) radius of the project site.
2.03 LUMBER MATERIALS
A. Hardwood Lumber: Maximum moisture content of 6 percent; with vertical grain, of quality suitable for transparent finish.
2.04 FASTENERS
A. Fasteners: Of size and type to suit application.
2.05 ACCESSORIES
A. Lumber for Shimming and Blocking: Softwood lumber ofspecies as suitable for each application.
REPLACE TROOP TRAINING QUARTERS 06200 - 3
B. Primer: Alkyd primer sealer.
C. Wood Filler: Solvent base, tinted to match surface finish color.
2.06 FABRICATION
A. Shop assemble work for delivery to site, permitting passage through building openings.
B. When necessary to cut and fit on site, provide materials with ample allowance for cutting. Provide trim for scribing and site cutting.
2.07 SHOP FINISHING
A. Sand work smooth and set exposed nails and screws.
B. Apply wood filler in exposed nail and screw indentations.
C. On items to receive transparent finishes, use wood filler that matches surrounding surfaces and is of type recommended for the applicable finish.
D. Finish work in accordance with AWI Section 1500 System TR-2 (Transparent).
E. Prime paint surfaces in contact with cementitious materials.
PART 3 EXECUTION
3.01 EXAMINATION
A. Verify adequacy of backing and support framing.
B. Verify mechanical, electrical, and building items affecting work of this section are placed and ready to receive this work.
3.02 INSTALLATION
A. Set and secure materials and components in place, plumb and level.
B. Carefully scribe work abutting other components, with maximum gaps of 1 mm (1/32 inch). Do not use additional overlay trim to conceal larger gaps.
3.03 PREPARATION FOR SITE FINISHING
A. Set exposed fasteners. Apply wood filler in exposed fastener indentations. Sand work smooth.
B. Site Finishing: See Section 09900.
C. Before installation, prime paint surfaces of items or assemblies to be in contact with cementitious materials.
3.04 TOLERANCES
A. Maximum Variation from True Position: 1.5 mm (1/16 inch).
B. Maximum Offset from True Alignment with Abutting Materials: 0.7 mm (1/32 inch).
3.05 SCHEDULE
A. Interior:
1. Moldings, Bases, Casings, and Miscellaneous Trim: Red Oak; prepare for
REPLACE TROOP TRAINING QUARTERS 06200 - 4
transparent finish.
2. Loose Shelving: Red Oak plywood; prepare for transparent finish.
REPLACE TROOP TRAINING QUARTERS 06410 - 1
SECTION 06410
CUSTOM CABINETS
1.01 SUMMARY
A. Section Includes:
1. Specially fabricated cabinet units.
2. Cabinet hardware.
3. Factory finishing.
B. Related Sections:
1. Section 01616 - Volatile Organic Compound (VOC) Content Restrictions.
2. Section 06100 - Rough Carpentry: Support framing, grounds, and concealed blocking.
3. Section 06415 - Countertops.
1.02 REFERENCE STANDARDS
A. ANSI/AHA A135.4 - American National Standard for Basic Hardboard; 2004.
B. AWI/AWMAC (QSI) - Architectural Woodwork Quality Standards Illustrated;
Architectural Woodwork Institute and Architectural Woodwork Manufacturers
Association of Canada; 2005, 8th Ed., Version 2.0.
C. HPVA HP-1 - American National Standard for Hardwood and Decorative Plywood;
Hardwood Plywood & Veneer Association; 2004 (ANSI/HPVA HP-1).
D. NHLA G-101 - Rules for the Measurement & Inspection of Hardwood & Cypress;
National Hardwood Lumber Association; 2007.
E. PS 20 - American Softwood Lumber Standard; National Institute of Standards and
Technology (Department of Commerce); 2005.
1.03 SYSTEM REQUIREMENTS
A. LEED Requirements
1. Provide wood based materials and products which are certified in accordance with the Forest Stewardship Council's (FSC) Principles and Criteria for wood building components.
2. Products supplied as part of this section shall contain no added urea-formaldehyde resins. Laminated adhesives used to fabricate on-site and shop-applied composite wood assemblies shall contain no urea-formaldehyde resins.
3. Provide sealants and adhesives that meet or exceed the VOC benchmarks set forth by the South Coast Air Quality Management District (SCAQMD).
4. Give preference to products extracted/harvested/recovered and manufactured within
800 km (500 miles) of the project site.
1.04 SUBMITTALS
A. Shop Drawings: Indicate materials, component profiles and elevations, assembly methods, joint details, fastening methods, accessory listings, hardware location and
REPLACE TROOP TRAINING QUARTERS 06410 - 2
schedule of finishes.
B. Product Data: Provide data for hardware accessories.
C. Samples: Submit actual samples of architectural cabinet construction, minimum 300 mm (12 inches) square, illustrating proposed cabinet substrate and finish.
D. Samples: Submit actual sample items of proposed pulls and hinges, demonstrating hardware design, quality, and finish.
E. LEED Report:
1. Submit applicable LEED Submittal Form for each different product made of sustainably harvested wood as well as locally-sourced wood, as specified in Section
01355. Provide Chain-of-Custody (COC) certifications as part of the submission.
2. Submit applicable LEED Submittal Form for each different product showing no urea-formaldehyde resins were used in products of this section as specified in
Section 01355 and 01363
3. Submit product data showing the VOC content of each adhesive and/or sealant used.
4. Submit applicable LEED Submittal Form for each different product extracted/harvested/recovered and manufactured within 800 km (500 miles) of the project site
1.05 QUALITY ASSURANCE
A. Perform work in accordance with AWI/AWMAC Architectural Woodwork Quality
Standards Illustrated, Premium quality, unless other quality is indicated for specific items.
B. Perform cabinet construction in accordance with AWI/AWMAC Architectural
Woodwork Quality Standards Illustrated, Premium quality, unless other quality is indicated for specific items.
C. Manufacturer Qualifications: Company specializing in manufacturing the products specified in this section with minimum three years of documented experience.
1.06 DELIVERY, STORAGE, AND HANDLING
A. Deliver materials to the site protected from the weather and in an undamaged condition.
Exercise care when off-loading lumber and such products subject to damage. In the event of damage make replacements at no increase in Contract Price.
B. Store lumber and wood products in such a manner as to ensure proper ventilation and drainage and to protect against damage and the weather.
C. Protect units from moisture damage.
1.07 FIELD CONDITIONS
A. During and after installation of custom cabinets, maintain temperature and humidity conditions in building spaces at same levels planned for occupancy.
B. For a minimum of 72 hours prior to installation, allow woodwork to come to equilibrium onsite in space where it is to be installed.
REPLACE TROOP TRAINING QUARTERS 06410 - 3
C. Humidity: For 24 hours before, during, and after installation, maintain relative humidity between 25 and 55 percent.
D. Temperature: For 24 hours before, during, and after installation, maintain ambient temperature between 65 and 75 degrees F.
PART 2 PRODUCTS
2.01 WOOD-BASED COMPONENTS
A. Wood fabricated from old growth timber is not permitted.
B. Provide sustainably harvested wood, certified or labeled as specified in Section 01600.
C. Provide wood harvested within a 805 km (500 mile) radius of the project site.
2.02 LUMBER MATERIALS
A. Softwood Lumber: NIST PS 20; Graded in accordance with AWI/AWMAC
Architectural Woodwork Quality Standards Illustrated, Grade III/Economy; average moisture content of 6-12 percent; species as recommended by manufacturer.
B. Hardwood Lumber: NHLA; Graded in accordance with AWI/AWMAC Architectural
Woodwork Quality Standards Illustrated, Grade I/Premium; average moisture content of
4-9 percent; species oak
2.03 PANEL MATERIALS
A. Veneer Faced Plywood Finish: HPVA HP-1; graded in accordance with
AWI/AWMAC Architectural Woodwork Quality Standards Illustrated, core of veneer
(wood plies) or lumber; type of glue recommended for specific application; thickness as required; face veneer as follows:
1. Exposed Surfaces: Grade AA, Red Oak, plain sliced, book-matched.
2. Semi-Exposed Surfaces: Grade A, Red Oak, plain sliced, book-matched.
3. Concealed Surfaces: Grade B, Red Oak, plain sliced, random-matched.
B. Hardboard: ANSI/AHA A135.4; Pressed wood fiber with resin binder, Class 1 -
Tempered, 6 mm (1/4 inch) thick, smooth one side (S1S); use for drawer bottoms, dust panels, and other components indicated on drawings.
C. Hardwood Edgebanding: Use solid hardwood edgebanding matching species, color, grain, and grade for exposed portions of cabinetry.
2.04 COUNTERTOPS
A. As specified in Section 06415.
2.05 ACCESSORIES
A. Adhesive: Type recommended by AWI/AWMAC to suit application.
B. Fasteners: Size and type to suit application.
C. Bolts, Nuts, Washers, Lags, Pins, and Screws: Of size and type to suit application;
galvanized or chrome-plated finish in concealed locations and stainless steel, or chrome-plated finish in exposed locations.
REPLACE TROOP TRAINING QUARTERS 06410 - 4
D. Concealed Joint Fasteners: Threaded steel.
2.06 HARDWARE
A. Adjustable Shelf Supports: Standard side-mounted system using multiple holes for pin supports and coordinated self rests, polished chrome finish, for nominal 25 mm (1 inch) spacing adjustments.
B. Drawer and Door Pulls: "U" shaped wire pull, aluminum with satin finish, 100 mm centers ("U" shaped wire pull, aluminum with satin finish, 4 inch centers).
C. Catches: Magnetic.
D. Drawer Slides:
1. Type: Full extension.
2. Static Load Capacity: Heavy Duty grade.
3. Mounting: Side mounted.
4. Stops: Integral type.
5. Features: Provide self closing/stay closed type.
6. Manufacturers:
a. Accuride International, Inc: www.accuride.com.
b. Grass America Inc: www.grassusa.com.
c. Knape & Vogt Manufacturing Company: www.knapeandvogt.com.
E. Hinges: Concealed (fully mortised) self-closing type, steel with satin finish.
1. Manufacturers:
a. Grass America Inc: www.grassusa.com.
b. Hardware Resources: www.hardwareresources.com.
c. Julius Blum, Inc: www.blum.com.
F. Sliding Door Track Assemblies: Upper and lower track of satin anodized aluminum, with matching shoe equipped with nylon rollers.
2.07 SITE FINISHING MATERIALS
A. Stain, Varnish and Finishing Materials: As specified in Section 09900.
2.08 FABRICATION
A. Cabinet Style: Flush overlay.
B. Cabinet Doors and Drawer Fronts: Flush style.
C. Drawer Construction Technique: Dovetail joints.
D. Assembly: Shop assemble cabinets for delivery to site in units easily handled and to permit passage through building openings.
E. Edging: Fit shelves, doors, and exposed edges with specified edging. Do not use more than one piece for any single length.
F. Fitting: When necessary to cut and fit on site, provide materials with ample allowance for cutting. Provide matching trim for scribing and site cutting.
G. Matching Wood Grain: Comply with requirements of quality standard for specified
REPLACE TROOP TRAINING QUARTERS 06410 - 5
Grade and as follows:
1. Provide balance matched panels at each elevation.
2. Provide sequence matching across each elevation.
H. Provide cutouts for plumbing fixtures, outlet boxes, and fixtures and fittings. Verify locations of cutouts from on-site dimensions. Seal cut edges.
2.09 FACTORY FINISHING
A. Sand work smooth and set exposed nails and screws.
B. On items to receive transparent finishes, use wood filler matching or blending with surrounding surfaces and of types recommended for applied finishes.
C. Finish work in accordance with AWI/AWMAC Architectural Woodwork Quality
Standards Illustrated, Section 1500, Postcatalyzed Lacquer, Transparent.
PART 3 EXECUTION
3.01 EXAMINATION
A. Verify adequacy of backing and support framing.
B. Verify location and sizes of utility rough-in associated with work of this section.
3.02 INSTALLATION
A. Set and secure custom cabinets in place, assuring that they are rigid, plumb, and level.
B. Use fixture attachments in concealed locations for wall mounted components.
C. Use concealed joint fasteners to align and secure adjoining cabinet units.
D. Carefully scribe casework abutting other components, with maximum gaps of 1 mm
(1/32 inch). Do not use additional overlay trim for this purpose.
E. Secure cabinets to floor using appropriate angles and anchorages.
F. Countersink anchorage devices at exposed locations. Conceal with solid wood plugs of species to match surrounding wood; finish flush with surrounding surfaces.
3.03 ADJUSTING
A. Adjust installed work.
B. Adjust moving or operating parts to function smoothly and correctly.
3.04 CLEANING
A. Clean casework, counters, shelves, hardware, fittings, and fixtures.
REPLACE TROOP TRAINING QUARTERS 06415 - 1
SECTION 06415
COUNTERTOPS
1.01 SUMMARY
A. SECTION INCLUDES
1. Countertops for architectural cabinetwork.
2. Countertops for manufactured casework.
3. Wall-hung counters and vanity tops.
4. Sinks mounted to the underside of the countertops.
5. Window sills.
B. RELATED REQUIREMENTS
1. Section 06410 - Custom Cabinets.
1.02 REFERENCE STANDARDS
A. ANSI A208.1 - American National Standard for Particleboard; 1999.
B. ANSI Z124.3 - American National Standard for Plastic Lavatories; 2005.
C. ASTM E 84 - Standard Test Method for Surface Burning Characteristics of Building
Materials; 2008.
D. AWI/AWMAC (QSI) - Quality Standard Illustrated; Architectural Woodwork Institute and Architectural Woodwork Manufacturers Association of Canada; 2005, 8th Ed., Version 2.0.
E. ISSFA-2 - Classification and Standards for Solid Surfacing Material; International Solid
Surface Fabricators Association; 2001 (2002)
F. NEMA LD 3 - High-Pressure Decorative Laminates; 2005.
G. PS 1 - Structural Plywood; 2007.
1.03 SYSTEM DESCRIPTION
A. LEED Requirements
1. Provide wood based materials and products which are certified in accordance with the Forest Stewardship Council's (FSC) Principles and Criteria for wood building components.
a. Products supplied as part of this section shall contain no added urea-formaldehyde resins. Laminated adhesives used to fabricate on-site and shop-applied composite wood assemblies shall contain no urea-formaldehyde resins.
b. Provide sealants and adhesives that meet or exceed the benchmarks set forth by the South Coast Air Quality Management District (SCAQMD).
2. Give preference to products extracted/harvested/recovered and manufactured within
800 km (500 miles) of the project site.
3. Provide wood based materials and products which are certified in accordance with the Forest Stewardship Council's (FSC) Principles and Criteria for wood building
REPLACE TROOP TRAINING QUARTERS 06415 - 2
components.
4. Products supplied as part of this section shall contain no added urea-formaldehyde resins. Laminated adhesives used to fabricate on-site and shop-applied composite wood assemblies shall contain no urea-formaldehyde resins.
5. Provide sealants and adhesives that meet or exceed the VOC benchmarks set forth by the South Coast Air Quality Management District (SCAQMD).
6. Give preference to products extracted/harvested/recovered and manufactured within
800 km (500 miles) of the project site.
1.04 SUBMITTALS
A. Product Data: Manufacturer's data sheets on each product to be used, including:
1. Preparation instructions and recommendations.
2. Storage and handling requirements and recommendations.
B. Shop Drawings: Complete details of materials and installation; combine with shop drawings of cabinets and casework specified in other sections.
C. Verification Samples: For each finish product specified, minimum size 150 mm (6 inches) square, representing actual product, color, and patterns.
D. Test Reports: Chemical resistance testing, showing compliance with specified requirements.
E. LEED Report:
F. Submit applicable LEED Submittal Form for each different product made of sustainably harvested wood as well as locally-sourced wood, as specified in Section 01355.
Provide Chain-of-Custody (COC).
1. Submit applicable LEED Submittal Form for each different product showing no urea-formaldehyde resins were used in products of this section as specified in
Section 01355 and 01363.
2. Submit product data showing the VOC content of each adhesive and/or sealant used.
3. Submit applicable LEED Submittal Form for each different product extracted/harvested/recovered and manufactured within 800 km (500 miles) of the project site.
G. Installation Instructions: Manufacturer's installation instructions and recommendations.
H. Maintenance Data: Manufacturer's instructions and recommendations for maintenance and repair of countertop surfaces.
1.05 QUALITY ASSURANCE
A. Fabricator Qualifications: Same fabricator as for cabinets on which tops are to be installed.
B. Installer Qualifications: Fabricator.
1.06 DELIVERY, STORAGE, AND HANDLING
A. Store products in manufacturer's unopened packaging until ready for installation.
REPLACE TROOP TRAINING QUARTERS 06415 - 3
B. Store and dispose of solvent-based materials, and materials used with solvent-based materials, in accordance with requirements of local authorities having jurisdiction.
1.07 FIELD CONDITIONS
A. Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits.
PART 2 PRODUCTS
2.01 COUNTERTOP ASSEMBLIES
A. Solid Surfacing Countertops and Sills: Solid surfacing sheet or plastic resin casting over continuous substrate.
1. Flat Sheet Thickness: 12 mm (1/2 inch), minimum.
2. Solid Surfacing Sheet and Plastic Resin Castings: Complying with ISSFA-2 and
NEMA LD 3; acrylic resin, mineral filler, and pigments; homogenous, non-porous and capable of being worked and repaired using standard woodworking tools; no surface coating; color and pattern consistent throughout thickness.
a. Surface Burning Characteristics: Flame spread 25, maximum; smoke developed 450, maximum; when tested in accordance with ASTM E 84.
b. NSF approved for food contact.
c. Sinks and Bowls: Separate units for undercounter mounting; minimum 19 mm (3/4 inch) wall thickness; comply with ANSI Z124.3.
d. Finish on Exposed Surfaces: Matte, gloss rating of 5 to 20.
e. Color and Pattern: As scheduled.
f. Manufacturers:
1) Dupont: www.corian.com.
2) Formica Corporation: www.formica.com.
3) Avonite Surfaces: www.avonitesurfaces.com.
4) Wilsonart International, Inc: www.wilsonart.com.
5) Or approved equal.
3. Other Components Thickness: 12 mm (1/2 inch), minimum.
4. Exposed Edge Treatment: Built up to minimum 32 mm (1-1/4 inch) thick;
bullnosed edge.
5. Back and End Splashes: Same sheet material, radiused top; minimum 152 mm (6 inches) high.
6. Skirts: As indicated on drawings.
2.02 ACCESSORY MATERIALS
A. Wood-Based Components:
1. Wood fabricated from old growth timber is not permitted.
B. Plywood for Supporting Substrate: PS 1 Exterior Grade, A-C veneer grade, minimum
5-ply; minimum 19 mm (3/4 inch) thick; join lengths using metal splines.
C. Adhesives: Chemical resistant waterproof adhesive as recommended by manufacturer of materials being joined.
D. Joint Sealant: Mildew-resistant silicone sealant, clear.
REPLACE TROOP TRAINING QUARTERS 06415 - 4
2.03 FABRICATION
A. Fabricate in accordance with standards governing fabrication quality that are specified in Section 06410.
B. Fabricate tops and splashes in the largest sections practicable, with top surface of joints flush.
1. Join lengths of tops using best method recommended by manufacturer.
2. Fabricate to overhang fronts and ends of cabinets 25 mm (1 inch) except where top butts against cabinet or wall.
3. Prepare all cutouts accurately to size; replace tops having improperly dimensioned or unnecessary cutouts or fixture holes.
C. Provide back/end splash wherever counter edge abuts vertical surface unless otherwise indicated.
1. Secure to countertop with concealed fasteners and with contact surfaces set in waterproof glue.
2. Height: 150 mm (6 inches), unless otherwise indicated.
D. Solid Surfacing: Fabricate tops up to 3657 mm (144 inches) long in one piece; join pieces with adhesive sealant in accordance with manufacturer's recommendations and instructions.
E. Wall-Mounted Counters: Provide skirts and aprons as indicated on drawings, finished to match.
PART 3 EXECUTION
3.01 EXAMINATION
A. Do not begin installation until substrates have been properly prepared.
B. If substrate preparation is the responsibility of another installer, notify Contracting
Officer or Designated Representative of unsatisfactory preparation before proceeding.
C. Verify that wall surfaces have been finished and mechanical and electrical services and outlets are installed in proper locations.
3.02 PREPARATION
A. Clean surfaces thoroughly prior to installation.
B. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions.
3.03 INSTALLATION
A. Securely attach countertops to cabinets using concealed fasteners. Make flat surfaces level; shim where required.
B. Seal joint between back/end splashes and vertical surfaces.
3.04 CLEANING AND PROTECTION
A. Clean countertops surfaces thoroughly.
REPLACE TROOP TRAINING QUARTERS 06415 - 5
B. Protect installed products until completion of project.
C. Touch-up, repair or replace damaged products before Substantial Completion.
REPLACE TROOP TRAINING QUARTERS 07212 - 1
SECTION 07212
BOARD AND BATT INSULATION
1.01 SUMMARY
A. Section Includes:
1. Board insulation at roof.
2. Batt insulation and vapor retarder in exterior wall construction.
3. Batt insulation for filling crevices in exterior wall and roof.
B. Related Sections:
1. Section 01616 - Volatile Organic Compound (VOC) Content Restrictions.
2. Section 04810 - Unit Masonry Assemblies.
3. Section 07411 - Standing Seam Roof Panels.
4. Section 07260 - Weather Barriers: Separate air barrier and vapor retarder materials.
1.02 REFERENCE STANDARDS
A. ASTM C 665 - Standard Specification for Mineral-Fiber Blanket Thermal Insulation for
Light Frame Construction and Manufactured Housing; 2006.
B. ASTM C 1289 - Standard Specification for Faced Rigid Cellular Polyisocyanurate
Thermal Insulation Board; 2007.
C. ASTM D 1622 - Apparent Density of Rigid Cellular Plastics.
D. ASTM E 84 - Standard Test Method for Surface Burning Characteristics of Building
Materials; 2008.
E. ASTM E 96/E 96M - Standard Test Methods for Water Vapor Transmission of
Materials; 2005.
F. ASTM E 136 - Standard Test Method for Behavior of Materials in a Vertical Tube
Furnace At 750 Degrees C; 2004.
G. Federal Specifications HH-I-1972/1 - Insulation Board Thermal, Polyurethane or
Isocyanurates Faced with Aluminum on Both Sides of Foam.
1.03 SYSTEM DESCRIPTION
A. LEED Requirements
1. Provide products, sealants, and adhesives that meet or exceed the VOC benchmarks set forth by the South Coast Air Quality Management District (SCAQMD).
2. Give preference to products that maximize the percentage of recycled content (both post consumer and post industrial).
3. Give preference to products extracted/harvested/recovered and manufactured within
800 km (500 miles) of the project site.
1.04 SUBMITTALS
A. Product Data: Provide data on product characteristics, performance criteria, and
REPLACE TROOP TRAINING QUARTERS 07212 - 2
product limitations.
B. Manufacturer's Installation Instructions: Include information on special environmental conditions required for installation and installation techniques.
C. Manufacturer's Certificate: Certify that products meet or exceed specified requirements.
D. LEED Report
1. Submit product data showing the VOC content of each product, adhesive and/or sealant used.
2. Submit applicable LEED Submittal Forms for each different product showing total recycled content and broken down into Post Consumer and Post Industrial percentages.
3. Submit applicable LEED Submittal Form for each different product extracted/harvested/recovered and manufactured within 800 km (500 miles) of the project site.
1.05 FIELD CONDITIONS
A. Do not install insulation adhesives when temperature or weather conditions are detrimental to successful installation.
PART 2 PRODUCTS
2.01 APPLICATIONS
A. Insulation at Roofs: Polyisocyanurate board.
B. Insulation at Metal Framed Trusses: Batt insulation with no vapor retarder.
2.02 FOAM BOARD INSULATION MATERIALS
A. Polyisocyanurate Board Roof Insulation: ASTM C1289; with the following characteristics:
1. Insulation: Two inches of closed cell HCFC free polyisocyanurate.
2. Facing: Top layer of 7/16 inch APA rated OSB with 1 inch ventalation spacing on top side and a fiber reinforced felt facer on the bottom.
3. Flame Spread Index: 75 or less, when tested in accordance with ASTM E 84.
4. Smoke Developed Index: 450 or less, when tested in accordance with ASTM E
84.
5. Board Size: 1220 x 2440 mm (48 x 96 inch).
6. Board thickness: 3 and 7/16 inch total thickness.
7. Board edges: Square.
8. Thermal resistance: R-value of 12.1 minimum.
9. FM Standard 4450/4470 approval 1-90; for use with Class A shingles and metal roofing;
10. Compressive strength of 20 psi.
11. Manufacturers:
a. Atlas Roofing Corporation; Product: ACFoam Crossvent.
b. Apache; Product: Nail line.
c. RMAX, Inc; Product: Nailable Base.
REPLACE TROOP TRAINING QUARTERS 07212 - 3
d. Or approved equal.
B. Polyisocyanurate Board Insulation: Rigid cellular foam, complying with ASTM C
1289; Type II, Class 1, cellulose felt or glass fiber mat both faces; Grade 1.
1. Flame Spread Index: 75 or less, when tested in accordance with ASTM E 84.
2. Smoke Developed Index: 450 or less, when tested in accordance with ASTM E
84.
3. Compressive Strength: 110 kPa (16 psi)
4. Facing: Asphalt felt or mat both faces.
5. Board Size: 1220 x 2440 mm (48 x 96 inch).
6. Board Thickness: 50 mm (2 inch) per layer.
7. Board Edges: Square.
8. Thermal Conductivity (k factor): 0.27 (0.16).
9. Board Density: 29 kg/cu m (1.8 lb/cu ft).
10. Surface Burning Characteristics: Flame spread/Smoke developed of 25/25 in accordance with ASTM E 84.
11. Manufacturers:
a. Atlas Roofing Corporation: AC Foam Supreme; www.atlasroofing.com.
b. GAF Materials Corporation: www.gaf.com.
c. Dow Chemical USA; TUFF-R "C".
d. NRG Barriers, Inc.; Barrier Board.
e. Or Approved Equal.
2.03 BATT INSULATION MATERIALS
A. Where batt insulation is indicated, either glass fiber or mineral fiber batt insulation may be used, at Contractor's option.
B. Glass Fiber Batt Insulation: Flexible preformed batt or blanket, complying with ASTM
C 655; friction fit.
1. Flame Spread Index: 25 or less, when tested in accordance with ASTM E 84.
2. Smoke Developed Index: 450 or less, when tested in accordance with ASTM E
84.
3. Combustibility: Non-combustible, when tested in accordance with ASTM E 136, except for facing, if any.
4. Formaldehyde Content: Zero.
5. Thermal Resistance: As shown on drawings.
6. Facing: Unfaced.
7. Recycled content: 25% by weight, minimum.
8. Manufacturers:
a. Johns Manville Corporation: www.jm.com.
b. CertainTeed Corporation: www.certainteed.com.
c. Owens Corning Corp: www.owenscorning.com.
d. Schuller International.
e. Or Approved Equal.
C. Mineral Fiber Batt Insulation: Flexible preformed batt or blanket, complying with
ASTM C 665; friction fit; unfaced flame spread index of 0 (zero) when tested in accordance with ASTM E 84.
REPLACE TROOP TRAINING QUARTERS 07212 - 4
1. Smoke Developed Index: 0 (zero), when tested in accordance with ASTM E 84.
2. Thermal Resistance: As shown on drawings.
3. Manufacturers:
a. Thermafiber, Inc: www.thermafiber.com.
b. Or Approved Equal.
c. Substitutions: See Section 01600 - Product Requirements.
2.04 ACCESSORIES
A. Sheet Vapor Retarder: Specified in Section 07260.
B. Insulation Fasteners: Impaling clip of galvanized steel with washer retainer and clips, to be adhered to surface to receive insulation, length to suit insulation thickness and substrate, capable of securely and rigidly fastening insulation in place.
C. Nails or Staples: Steel wire; electroplated, or galvanized; type and size to suit application.
D. Wire Mesh: Galvanized steel, hexagonal wire mesh.
E. Adhesive: Type recommended by insulation manufacturer for application.
PART 3 EXECUTION
3.01 EXAMINATION
A. Verify that substrate, adjacent materials, and insulation materials are dry and that substrates are ready to receive insulation and adhesive.
B. Verify substrate surfaces are flat, free of honeycomb, fins, irregularities, or materials or substances that may impede adhesive bond.
3.02 BOARD INSULATION OVER METAL DECK
A. Attachment of Insulation: Mechanically fasten each layer of insulation to deck in accordance with roofing manufacturer's instructions.
B. Lay subsequent layers of insulation with joints staggered minimum 150 mm (6 inch) from joints of preceding layer.
C. On metal deck, place boards parallel to flutes with insulation board edges bearing on deck flutes.
D. Lay boards with edges in moderate contact without forcing. Cut insulation to fit neatly to perimeter blocking and around penetrations through roof.
E. Tape joints of insulation in accordance with roofing and insulation manufacturers' instructions.
F. Do not apply more insulation than can be covered with roof surface in same day.
3.03 BATT INSTALLATION
A. Install insulation and vapor retarder in accordance with manufacturer's instructions.
B. Install in exterior wall and roof spaces without gaps or voids. Do not compress insulation.
REPLACE TROOP TRAINING QUARTERS 07212 - 5
C. Trim insulation…