Attachment_2-_Fuel_Tank.pdf

PDF 891 KB Posted

Attached to
Repair Maintenance Ramp Federal contract opportunity
Solicitation number
W912JV-19-B-7001
Issued by
Department of the Army Oregon Army National Guard

About this file

This document includes an attachment related to relocating a fuel tank and area light, as well as details of a related federal contract opportunity. The attachment provides specifications for relocating an existing fuel tank and area light, including abandoning existing conduit, removing and relocating an emergency shut off button, installing new conduit and junction boxes, and placing an emergency button post. The related federal contract opportunity is solicitation number W912JV-19-B-7001 to perform repair and maintenance work at a ramp. The solicitation does not provide further description and is issued by the Department of the Army Oregon Army National Guard.

Attachment 2 Fuel Tank

View the file

Other files for this federal contract opportunity

Other files attached to Repair Maintenance Ramp, newest first.
File Type Posted
FINAL_RFI's_as_of_7_June_19.pdf PDF
Attachment_4_-_Exhibit_7460.PDF PDF
Attachment_3-_Fuel_Tank_Trench.pdf PDF
FINAL_RFI's_as_of_7_June_19.pdf PDF
01_40_00_General_Projects_and_Quality.pdf PDF
01_72_00_Warranties.pdf PDF
01_78_23_O_and_M_Data.pdf PDF
01_72_00_Record_Documents.pdf PDF
RFI's_as_of_1_June_19.pdf PDF
01_78_00_Contract_Closeout.pdf PDF
01_33_00_Submittals.pdf PDF
01_14_00_Security_Requirements.pdf PDF
01_39_00_Request_for_Information.pdf PDF
RFI's_as_of_30_May.pdf PDF
Revised_Specs.pdf PDF
RFI's.pdf PDF
Drawings.pdf PDF
Specifications.pdf PDF
W912JV19B7001.pdf PDF
Show all 19

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

3.00

177.±

AutoCAD SHX Text

PINE TREE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 06.

AutoCAD SHX Text RELOCATE FUEL TANK. 01. Fuel tank to be Fuel tank to be relocated. 02. Area light to be Area light to be relocated. 03. Conduit shall be Conduit shall be abandoned in place. 04. Remove and Remove and relocate emergency shut off button and pull control wire back to mech. rm. 05. Panel beakers Panel beakers 20-22 20amp. transformer for low voltage emergency button. 06. (N) 1" conduit sch . (N) 1" conduit sch (N) 1" conduit sch 40 PVC underground. GRC above ground connected to existing explosion proof J.boxes. For fuel pump and area light. with " 34" conduit placed for emergency shut off button. 07. Emergency button Emergency button placed on, 6"x6"x.187x6' HSS post, 2' placed in concrete, 4' aboveground. Top of post welded closed and neatly cleaned up and post painted red. located 4' off edge of pavement. 08. (N) location of . (N) location of (N) location of area light. 09. (N) location of (N) location of fuel tank, placed on existing 10"thick pcc slab. See attached sheet for trenching.

AutoCAD SHX Text

AutoCAD SHX Text 03.

AutoCAD SHX Text 04.

AutoCAD SHX Text

MECH

AutoCAD SHX Text

RM

AutoCAD SHX Text 07.

AutoCAD SHX Text 09.

AutoCAD SHX Text 08.

AutoCAD SHX Text 05.

AutoCAD SHX Text

SCALE 1:20

Sheets and Views
Ramp fuel tank-B-sizeLandscape
plot