AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
The purpose of this amendment is to incorporate:
1. Addndum 03 dated 16 April 2012 and detailed documenst below .
A-313-0 A-402 A-611 I-650 I-651
2. Adendum 04 dated 19 April 2012.
1. CONTRACT ID CODE PAGE OF PAGES
J 1 11
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 23-Apr-2012
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W912J6-12-R-0002
X 9B. DATED (SEE ITEM 11)
28-Feb-2012
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
21-Apr-2012
CODE
USPFO FOR HAWAII
CPT MANUEL LLANES
91-1179 ENTERPRISE AVE
KAPOLEI HI 96707-2150
W912J6 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
W912J6-12-R-0002
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION SF 30 - BLOCK 14 CONTINUATION PAGE
The following have been added by full text:
ADDENDUM 03
HIARNG Kalaeloa Readiness Center (RC) W90FY-Q-09-D-0006-9N02 Kalaeloa, Hawaii PN 150043
Addendum 003 16 April 2012 Page 1
ADDENDUM 003
16 April 2012
This Amendment consists of 11 pages including all attachments noted herein.
MODIFICATIONS TO DRAWINGS:
1) Sheet S-511 – FLOOR FRAMING SECTIONS AND DETAILS
a. Details 6/S-511 and 7/A-511: Revise “L2 x 2 x 3/16 CONT.” to L2 x 3 x 3/16 CONT. LLV”.
2) Sheet A-101A – FIRST FLOOR PLAN – SECTOR A
Sheet A-102A – SECOND FLOOR PLAN – SECTOR A Sheet A-402 – ENLARGED FLOOR PLANS – RESTROOMS
a. Wall modified and door deleted and replaced by toilet partition and toilet partition door at entrance to HC Showers:
i. RM. 1181 – MEN’S HC SHOWER #1
ii. RM. 1191 – WOMEN’S HC SHOWER #1
iii. RM. 2161 – MEN’S HC SHOWER #2
iv. RM. 2171 – WOMEN’S HC SHOWER #2
3) Sheet A-111A – FIRST FLOOR REFLECTED CEILING PLAN – SECTOR A
Sheet A-111B – FIRST FLOOR REFLECTED CEILING PLAN – SECTOR B Sheet A-112A – SECOND FLOOR REFLECTED CEILING PLAN – SECTOR A Sheet A-112B – SECOND FLOOR REFLECTED CEILING PLAN – SECTOR B Sheet A-421 – ENLARGED REFLECTED CEILING PLAN - AUDITORIUM, FIRST FLOOR -BASE
BID CONDITION
Sheet A-421.O – ENLARGED REFLECTED CEILING PLAN - AUDITORIUM, FIRST FLOOR - OBI
#1 CONDITION
Sheet A-422 – ENLARGED REFLECTED CEILING PLAN - AUDITORIUM, SECOND FLOOR -
BASE BID CONDITION
Sheet A-422.O – ENLARGED REFLECTED CEILING PLAN - AUDITORIUM, SECOND FLOOR -
OBI #1 CONDITION
Sheet A-423– ENLARGED REFLECTED CEILING PLANS – COMMAND SUITE Sheet A-424– ENLARGED REFLECTED CEILING PLANS – COMMAND SUITE Sheet A-425– ENLARGED REFLECTED CEILING PLANS – CLASSROOMS Sheet A-426– ENLARGED REFLECTED CEILING PLANS – CLASSROOMS HIARNG Kalaeloa Readiness Center (RC) W90FY-Q-09-D-0006-9N02 Kalaeloa, Hawaii PN 150043 Addendum 003 16 April 2012 Page 2
Revise REFLECTED CEILING PLAN KEYNOTES Legend as follows:
a. Keynote 15, revise to read: “LINEAR WOOD CEILINGS, WDC1, @ 10’-0”AFF, WITH 3/8”
REVEALS BETWEEN WDC1 PANELS & SOFFIT PERIMETER, UNLESS NOTED OTHERWISE.”
b. Keynote 17, revise to read: “LINEAR WOOD CEILINGS, WDC1, @ 28’-4”AFF, WITH 3/8”
REVEALS BETWEEN WDC1 PANELS & SOFFIT PERIMETER, UNLESS NOTED OTHERWISE.”
c. Keynote 20, revise to read: “LINEAR WOOD CEILINGS, WDC1, @ 27’-4”AFF, WITH 3/8”
REVEALS BETWEEN WDC1 PANELS & SOFFIT PERIMETER, UNLESS NOTED OTHERWISE.”
d. Keynote 24, revise to read: “LINEAR WOOD CEILINGS, WDC1, @ 9’-4”AFF, WITH 3/8”
REVEALS BETWEEN WDC1 PANELS & SOFFIT PERIMETER, UNLESS NOTED OTHERWISE.”
e. Keynote 27, revise to read: “FABRIC WRAPPED CEILING PANEL FCP1, @ 27’-11” AFF DIRECT
MOUNTED TO PAINTED GYP. BD. CEILING, PT3, @ 28’-1 1/4" AFF.
4) Sheet A-313.O – ENLARGED BUILDING SECTIONS – AUDITORIUM – OBI#1 CONDITION
a. See attached Sheet A-313.O for modifications described below.
b. Detail 2/A-313.O: revise note “ACOUSTICAL WOOD PANEL, AWP1, OVER 3/4" PLYWOOD ON 3-5/8” METAL STUD FRAMING – ALL EXPOSED EDGES TO BE FACTORY FINISHED” to read
“ACOUSTICAL WOOD PANEL, AWP2, OVER 3/4" PLYWOOD ON 3-5/8” METAL STUD
FRAMING – ALL EXPOSED EDGES TO BE FACTORY FINISHED”.
c. Detail 5/A-313.O: revise note “STONE CAP SET IN CONTINUOUS BED OF ADHESIVE” to read “3 CM STONE CAP, ST1, SET IN CONTINUOUS BED OF ADHESIVE”. Revise note
“ACOUSTICAL WOOD PANEL, AWP1, OVER 3/4" PLYWOOD ON 3-5/8” METAL STUD
FRAMING – ALL EXPOSED EDGES TO BE FACTORY FINISHED” to read “ACOUSTICAL WOOD
PANEL, AWP2, OVER 3/4" PLYWOOD ON 3-5/8” METAL STUD FRAMING – ALL EXPOSED
EDGES TO BE FACTORY FINISHED”.
d. Detail 7/A-313.O: revise note “STONE CAP SET IN CONTINUOUS BED OF ADHESIVE” to read
“3 CM STONE CAP, ST1, SET IN CONTINUOUS BED OF ADHESIVE”.
e. Detail 10/A-313.O: revise note “STONE CAP SET IN CONTINUOUS BED OF ADHESIVE” to read “3 CM STONE CAP, ST1, SET IN CONTINUOUS BED OF ADHESIVE”. Revise note
“ACOUSTICAL WOOD PANEL, AWP1, OVER 3/4" PLYWOOD ON 3-5/8” METAL STUD
FRAMING – ALL EXPOSED EDGES TO BE FACTORY FINISHED” to read “ACOUSTICAL WOOD
PANEL, AWP2, OVER 3/4" PLYWOOD ON 3-5/8” METAL STUD FRAMING – ALL EXPOSED
EDGES TO BE FACTORY FINISHED”.
5) Sheet A-314.O – ENLARGED PARTIAL BUILDING SECTIONS – AUDITORIUM – OBI #1
CONDITION
a. Detail 3/A-314.O: revise note “STONE WALL CAP – SEE INTERIOR DRAWINGS FOR ADDITIONAL INFORMATION” to read “3 CM STONE WALL CAP, ST1.”
Addendum 003 16 April 2012 Page 3
6) Sheet A-322 – WALL SECTIONS
a. Revise WALL SECTION 2/A322 detail note to read:
“HIGH IMPACT, ACOUSTICAL FABRIC-WRAPPED WALL PANEL (FWP3)”
7) Sheet A-401 – TYPICAL RESTROOM, SHOWER DETAILS AND ACCESSORY SCHEDULE Sheet A-402 – ENLARGED FLOOR PLANS – RESTROOMS
a. TOILET ACCESSORY SCHEDULE, revise MARK 23, DESCRIPTION to read:
“TOILET STALL, FLOOR AND CEILING ANCHORED – ACCESSIBLE”.
b. TOILET ACCESSORY SCHEDULE, revise MARK 24, DESCRIPTION to read:
“TOILET STALL, FLOOR AND CEILING ANCHORED – STANDARD”.
c. TOILET ACCESSORY SCHEDULE, add MARK 28, DESCRIPTION to read:
“H/C SHOWER STALL PARTITION AND DOOR”.
8) Sheet A-401 – TYPICAL RESTROOM, SHOWER DETAILS AND ACCESSORY SCHEDULE
a. Detail 3/A-401, revise Detail reference 3/A-541 to 6/S-511.
9) Sheet A-402 – ENLARGED FLOOR PLANS – RESTROOMS
a. Details 4/A-402 and 8/A-402 revised to indicate modified wall and door deleted, replaced by toilet partition and partition door at entrance to HC Showers – see attached Sheet A-402.
10) Sheet A-406 – ENLARGED FLOOR PLANS
a. Detail 1/A-406 PARTIAL ENLARGED FLOOR PLAN, remove NOTE: “SCHEDULED CORNER
GUARD”
11) Sheet A-411 – INTERIOR ELEVATIONS – LOBBY
Sheet A-412 – INTERIOR ELEVATIONS – LOBBY Sheet A-413 – INTERIOR ELEVATIONS – AUDITORIUM - BASE BID CONDITION Sheet A-413.O – INTERIOR ELEVATIONS – AUDITORIUM - OBI #1 CONDITION Sheet A-414 – INTERIOR ELEVATIONS – ASSEMBLY HALL Sheet A-415 – INTERIOR ELEVATIONS – ASSEMBLY HALL Sheet A-416 – INTERIOR ELEVATIONS Revise KEYNOTES Legend as follows:
a. Keynote 1, revise to read: “WOOD WALL PANEL (WDP1) SEE DETAIL 1/I-651.
b. Keynote 2, revise to read: “WOOD WALL PANEL (WDP2) SEE DETAIL 2/I-651.
c. Keynote 26, revise to read: “WOOD WALL PANEL (WDP3) SEE DETAIL 1/I-651.
12) Sheet A-413.O – INTERIOR ELEVATIONS – AUDITORIUM – OBI #1 CONDITION
a. Detail 3/A413.O: WD2 hatch at balcony to be adjusted to read as WD3 finish.
Addendum 003 16 April 2012 Page 4
13) Sheet A-541 – CEILING DETAILS
a. Delete Detail 3/A-541
14) Sheet A-611 – DOOR SCHEDULE:
a. See attached Sheet A-611 – DOOR SCHEDULE for modifications described below.
b. Delete Door 1013I and Door 1013J from the Door Schedule. These doors are not in the project.
c. Delete Doors 1181A, 1191A, 2161A and 2171A. These doors are being revised to toilet par-titions.
d. Add Door EL1:
i. Name – ELEVATOR
ii. Width – 3’-6”
iii. Height – 7’-0”
iv. Door Type – STL
v. Door Type – L
vi. Fire Rating – 90 MIN.
e. Doors 1000A, 1000C: Add remark “4”.
f. Doors 1017A, 1100A, 1220A, 2180A: Delete “45 MIN.” Fire Rating.
g. Doors 1060A, 2030A, 2050A, 2060A, 2070A, 2130A, 2210A, 2220A:
Revise Door Type from “D” to “C”.
h. Doors 1021A, 1061A, 1062A, 1241A, 1242A, 2051A:
Revise Door Type from “C” to “G”; delete “45 MIN.” Fire Rating.
i. Door 1120A: Revise Room Name from “CORRIDOR” to “WOMEN #2.
j. Doors 1201A, 1202A: Revise Door Width from “4’-4”” to “3’-6””.
k. Door 1240A: Revise Door Type from “C” to “E”.
l. Door 1247A: Revise Room Name from “CORRIDOR” to JAN. CLOS.”
m. Doors 2000A, 2000B: Revise Door Type from “G” to “H”.
n. Doors 1250B, 1250C: Revise Door Type from “C” to “H”; delete “45 MIN.” Fire Rating.
o. Door 2041A: Add Door Type “C”.
p. Doors 2131A and 2132A, delete bubble and reference to OBI#1. These doors are not includ-ed in the scope of OBI#1.
q. Doors 2140A and 2140B Add bubble and reference to OBI#1. These doors are included in the scope of
OBI#1.
r. Door 2150A: Revise Room Name from “CORRIDOR” to “JAN. CLOS.”; revise Door Height from “7’- 0”” to “8’-10””.
s. Door Schedule Remarks: Revise Remark 4 to read: “FIELD VERIFY OVERALL FRAME
DIMENSIONS – PROVIDE 3’-0” WIDE DOOR IF POSSIBLE”.
t. Door General Notes:
i. Renumber Door General Note “4” to “5”.
ii. Revise Door Note 3 to read: “GLASS IN DOOR PANEL AND SIDELIGHT TO BE TEMPERED
GLASS TYP.”
iii. Add new Door Note 4 to read: “GLAZING FOR LIGHTS IN FIRE RATED DOORS TO BE FIRE
RATED GLASS TYP. AS REQUIRED TO MEET DOOR RATING”.
u. Door Types: Delete “TYPE “D” – SINGLE FLUSH W/ GLASS. This Door Type is no long-er applicable to the project.
Addendum 003 16 April 2012 Page 5
15) Sheet I-410 – AUDITORIUM SEATING DIAGRAMS
a. Revise Total Seat Count TABLE FIRST FLOOR to read as follows;
“TOTAL SEAT COUNT
FIRST FLOOR
- BASE BID 312
- OBI#1 – ADDITIONAL SEATS REQ’D 2
OBI# 1 CONDITION – TOTAL SEATS 314
NOTE OBI #1 CONDITION – TOTAL SEATS INCLUDES BASE BID SEATING PLUS 2
ADDITIONAL SEATS FOR OBI#1”
16) Sheet I-650 – INTERIOR ROOM FINISH SCHEDULE
a. Interior Finish Abbreviations Legend: Add “WDP WOOD WALL PANEL”.
b. Room Finish Schedule: Adjust wall finishes from WD2, WD3, WD4 to WDP1, WDP2, WDP3 according to revised drawings.
17) Sheet I-651 – INTERIOR ROOM FINISH LEGEND
a. Interior Finish Abbreviations Legend: Add “WDP WOOD WALL PANEL”.
b. Add “DETAIL GENERAL NOTE” to 1/I-651 to read:
“1. WOOD WALL PANEL, WDP1, TO USE WD2 VENEER FINISH.
2. WOOD WALL PANEL, WDP3, TO USE WD3 VENEER FINISH.”
c. Adjust NOTES in the middle panel on detail 2/I-651 “SOLID WOOD EDGE – WD3” to read “SOLID WOOD EDGE – WD2”. “WOOD VENEER – WD3” to read “WOOD VENEER – WD4”. Refer revised drawings for further details.
d. On INTERIOR FINISH LEGEND add #6 to “NOTE” column on STT4 finish item.
MODIFICATIONS TO SPECIFICATIONS:
1) Specification Section 033000 – CAST-IN-PLACE CONCRETE:
a. Revise the first sentence in 3.9.F.1 to read:
“Maintain concrete temperature below 95 deg F at time of placement.”
b. The rest of 3.9.F.1 remains intact and is unchanged.
2) Specification Section 045000 – TERRA COTTA PANEL AND BAGUETTE LOUVER SYSTEM:
a. Revise 1.2.B.2 to read: “Extruded hollow terra cotta baguette/louvers – includes items indicated as terra cotta baguette sunshades on the Drawings.
3) Specification Section 10280 – TOILET, BATH AND LAUNDRY ACCESSORIES:
a. Revise “2.3.G – Liquid Soap Dispenser” to read “2.3.G – Wall Mounted Liquid Soap Dispenser”.
Addendum 003 16 April 2012 Page 6
b. Add “2.3.J – Lavatory Mounted Liquid Soap Dispenser” to read:
“J. Lavatory Mounted Liquid-Soap Dispenser:
1. Basis-of-Design Product: Bobrick #B-8226
2. Description: Designed for dispensing soap in liquid or lotion form.
3. Mounting: Deck mounted on lavatory.
4. Capacity: 34 oz.
5. Materials:
i. Piston, Spout and Top Cover: Type 304 stainless steel with bright polished finish.
ii. Container: Translucent shatter resistant polyethylene.”
c. Add “2.3.K – Soap Dish” to read:
“K. Soap Dish:
1. Basis-of-Design Product: Bobrick #B- 4390.
2. Description: With washcloth bar.
3. Mounting: Recessed
4. Material and Finish: Stainless steel, No. 4 finish (satin).”
4) Specification Section 321316 – CONCRETE PAVING:
a. Revise 2.3.A.1 to read:
“1. Portland Cement: ASTM C 150 Type 1.”
ATTACHMENTS:
1) Sheet A-313.O – ENLARGED BUILDING SECTIONS – AUDITORIUM – OBI#1 CONDITION
2) Sheet A-402 – ENLARGED FLOOR PLANS – RESTROOMS
3) Sheet A-611 – DOOR SCHEDULE
4) Sheet I-650 – INTERIOR ROOM FINISH SCHEDULE
5) Sheet I-651 – INTERIOR ROOM FINISH LEGEND
END OF ADDENDUM 003
ADDENDUM 04
Addendum 004 19 April 2012 Page 1
ADDENDUM 004
19 April 2012
This Amendment consists of 2 pages including all attachments noted herein.
MODIFICATIONS TO DRAWINGS:
1) Sheet C-103 – SITE PLAN – SECTOR TWO
a. Add the following note under Install Mobile Kitchen Trainer:
“Use Detail 5/C-502 for Mobile Kitchen Trainer Pad construction.”
2) Sheet C-122 – GRADING PLAN – SECTOR ONE
a. Add the following note to the 3 Stormwater Injection Bores indicated:
“Assume 50’ Bore Depth with a 1’ diameter.”
3) Sheet A-112B – SECOND FLOOR REFLECTED CEILING PLAN – SECTOR B
a. At Windows along Grid Line D.2 (high windows) add Window Tag 14.
Eight (8) Windows and associated Window Tags Total.
4) Sheet E-601 – ONE LINE DIAGRAM
a. Revise the notation associated with the feeder from the 200A switch and fuse in (SW2) to read:
“PROVIDE (3) #4/0, 15KV ALUMINUM CABLES IN A 5” CONDUIT, AND (1) SPARE 5”
CONDUIT TO NAVY 4.16KV SUBSTATION. REFER TO ELECTRICAL SITE PLAN ON SHEET E-
100A.”
b. The notation “TO NAVY 4.16KV SUBSTATION” along the line between (SW1) 600A switch and (SW2) 600A switch should be deleted.
MODIFICATIONS TO SPECIFICATIONS:
1) Specification Section 034100 – PRECAST STRUCTURAL CONCRETE:
a. Revise Honed Finish to Acid-Etched Finish. Revise 034100 – 2.15.A.2 to read:
“1. Acid-Etched Finish: Use acid and hot-water solution, equipment, application techniques, and cleaning procedures to expose matrix surfaces and provide a smooth panel surface with no large exposed aggregate visible. Protect hardware and connections from acid attack.
a. Typical for exposed exterior precast panels.” HIARNG Kalaeloa Readiness Center (RC) W90FY-Q-09- D-0006-9N02 Kalaeloa, Hawaii PN 150043 Addendum 004 19 April 2012 Page 2
2) Specification Section 034500 – PRECAST ARCHITECTURAL CONCRETE:
a. Revise Honed Finish to Acid-Etched Finish. Revise 034500 – 2.15.A.2 to read:
“1. Acid-Etched Finish: Use acid and hot-water solution, equipment, application techniques, and cleaning procedures to expose matrix surfaces and provide a smooth panel surface with no large exposed aggregate visible. Protect hardware and connections from acid attack.
b. Typical for exposed exterior precast panels.”
ATTACHMENTS: None
END OF ADDENDUM 004
(End of Summary of Changes)