Drawings_Volume_2_-_IFC_Recepton_Phase_1_AMD1.pdf

PDF 2 MB Posted

Attached to
Reception Complex Phase 1 Federal contract opportunity
Solicitation number
W912HP19R2000
Issued by
Department of the Army Corps of Engineers Engineering District Charleston

About this file

This solicitation package includes drawings, specifications, and attachments for a federal construction contract opportunity to build the Reception Complex, Phase 1 at Fort Jackson. Key details include construction of buildings, utilities, and site work according to four volumes of drawings and five volumes of specifications. Offerors must attend a mandatory site visit on August 20, 2019 and submit proposals by September 6, 2019. The Army Corps of Engineers Engineering District Charleston is the contracting agency for this project.

Drawings Vol2

View the file

Other files for this federal contract opportunity

Other files attached to Reception Complex Phase 1, newest first.
File Type Posted
B._AMD_0006_Solicitation_W912HP19R2000_Reception_Complex.pdf PDF
B._AMD0006_Solicitation_W912HP19R2001_BTC4.pdf PDF
B._AMD_0005_Solicitation_19R2000_Reception_Complex_Phase_1.pdf PDF
Specifications_Volume_5_-_IFC_Reception_Phase_1_AMD4.pdf PDF
B._AMD_0004_Solicitation_W912HP19R20000_Reception_Complex.pdf PDF
Drawings_Volume_2_-_IFC_Reception_Phase_1_AMD3.pdf PDF
B._AMD_0003_Solicitation_W912HP19R2000_Reception_Complex.pdf PDF
Drawings_Volume_1_-_IFC_Reception_Phase_1_AMD2.pdf PDF
Specifications_Volume_1_-_IFC_Reception_Phase_1_AMD2.PDF PDF
B._AMD_0002_Solicitation_W912HP19R2000_Reception_Complex.pdf PDF
Drawings_Volume_3_-_IFC_Reception_Phase_1_AMD2.pdf PDF
Drawings_Volume_2_-_IFC_Reception_Phase_1_AMD2.pdf PDF
Specifications_Volume_2_-_IFC_Reception_Phase_1_AMD2.PDF PDF
Specifications_Volume_5_-_IFC_Reception_Phase_1_AMD2.pdf PDF
Specifications_Volume_1_-_IFC_Reception_Phase_I_AMD1.pdf PDF
A._Site_Visit_Sign-In_Sheet.pdf PDF
Specifications_Volume_2_-_IFC_Reception_Phase_I_AMD1.pdf PDF
Drawings_Volume_1_-_IFC_Reception_Phase_1_AMD1.pdf PDF
Drawings_Volume_3_-_IFC_Reception_Phase_I_AMD1.pdf PDF
Specifications_Volume_5_-_IFC_Reception_Phase_AMD1.pdf PDF
Specifications_Volume_3_-_IFC_Reception_Phase_I_AMD1.pdf PDF
B._AMD_0001_Solicitation_W912HP19R2000_Reception_Complex.pdf PDF
junc-sp1.dgn —
junc-up.dgn —
junc-sp.dgn —
junv-rp.dgn —
junc-gp1.dgn —
junc-dp.dgn —
junv-tp.dgn —
junc-gp.dgn —
B._Attachment_2_-_Descriptive_Summary_Sheet.pdf PDF
Drawings_Volume_3_-_IFC_Reception_Phase_I.pdf PDF
B._Solicitation_W912HP19R2000_Reception_Complex_Phase_1,_Ft._Jax.pdf PDF
Drawings_Volume_4_-_IFC_Reception_Phase_I.pdf PDF
B._Attachment_1_-_Proposal_Data_Sheet.pdf PDF
Specifications_Volume_4_-_IFC_Reception_Phase_I.PDF PDF
Specifications_Volume_2_-_IFC_Reception_Phase_I.PDF PDF
Specifications_Volume_1_-_IFC_Reception_Phase_I.PDF PDF
Drawings_Volume_1_-_IFC_Reception_Phase_I.pdf PDF
Drawings_Volume_2_-_IFC_Reception_Phase_I.pdf PDF
B._Attachment_4_-_Small_Business_Participation_Plan.pdf PDF
Specifications_Volume_3_-_IFC_Reception_Phase_I.PDF PDF
Specifications_Volume_5_-_IFC_Reception_Phase_I.pdf PDF
B._Attachment_3_-_Past_Performance_Questionnaire.pdf PDF
Show all 44

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NOTE: SOME ITEMS MAY NOT BE USED

GENERAL NOTES ABBREVIATIONS

FA-MN-PA

FAA

F

S

FIRE ALARM/MASS

NOTIFICATION

SYSTEMS OPERATIONS

MATRIX

MANUAL FIRE ALARM PULL STATION

SPRINKLER WATER FLOW SWITCH

DUCT SMOKE DETECTORS

FACP SMOKE DETECTOR (ELECTRICAL ROOM)

CARBON MONOXIDE DETECTOR

BACK FLOW PREVENTER TAMPER SWITCH

SPRINKLER VALVE TAMPER SWITCH

PIV TAMPER SWITCH

FA-MN-PA CONTROL PANEL DOOR TAMPER SWITCH

TRANSCEIVER DOOR TAMPER SWITCH

KNOX BOX TAMPER SWITCH

FACP TROUBLE

IDC OPEN

IDC SHORT

IDC GROUND

AC POWER FAILURE

TEST MODE

LOW BATTERY VOLTAGE

MASS NOTIFICATION SYSTEM NOTIFICATION ACTIVATION

LIVE VOICE ANNOUNCEMENT FROM BASEWIDE SYSTEM

PRERECORDED MESSAGE # ACTIVATED

PRERECORDED ANNOUNCEMENT ACTIVATED AT LOC

LIVE VOICE ANNOUNCEMENT ACTIVATED AT LOC

FIRE ALARM NOTIFICATION MUTED BY MNS

FIRE PUMP RUNNING

FIRE PUMP POWER LOSS

FIRE PUMP PHASE REVERSAL

D

IS

PL

AY

E

VE

N

T M

ES

SA

G E

D

IS

PL

AY

C H

AN

G

E O

F

ST

AT

U

S

R

EC

O R

D E

VE

N

T

IN

T H

E H

IS

TO

R Y

LO

G

AN

N

U N

C

IA

TE

A

LA

R

M A

T

PA

N

EL

TR

AN

SM

IT

E

VE

N T

AL

AR

M

TR

AN

SM

IT

S U

PE

R

VI

SO

R Y

SI

G

N

AL

TR

AN

SM

IT

T R

O U

BL

E

SI

G

N

AL

AC

TI

VA

TE

C

LE

AR

F

A M

N S

N O

TI

FI

C

AT

IO

N

S

TR

O

BE

S

D

IS

PL

AY

T

EX

TU

R

AL

E

M

ER

G

EN

C Y

M

ES

SA

G

E D

IS

PL

AY

BR

O

AD

C

AS

T

FI

R

E

AL

AR

M

M

ES

SA

G

E

BR

O

AD

C

AS

T

R

EC

O R

D

ED

O R

L

IV

E M

AS

S

N O

TI

FI

C

AT

IO

N

M

ES

SA

G

E

M U

TE

F

IR

E

AL

AR

M M

ES

SA

G E

M U

TE

A

V

SO

U N

D R

EI

N

FO

R

C

EM

EN

T

SY

ST

EM

S

SH

U

T D

O W

N P

R O

TE

C

TE

D

A

IR

-H

AN

D

LI

N G

U N

IT

(S

N

O

TE

BY

-P

AS

S

EG

R

ES

S

LI

G

H

TI

N G

C O

N

TR

O

LS

MASS NOTIFICATION

FIRE PUMP

SUPERVISORY SIGNALS

FIRE ALARM

FIRE DETECTION AND MASS NOTIFICATION SYMBOLS

LOC

H

F NT

FA-MN-PA AND

FAA PANELS

SUPERVISORY

STATION

NOTIFICATION AUXILLIARY

FUNCTIONS

TROUBLE SIGNALS

K

AFF ABOVE FINISHED FLOOR

C CONDUIT

COR CONTRACTING OFFICER'S REPRESENTATIVE

FACP FIRE ALARM CONTROL PANEL

GFCI GOVERNMENT FURNISHED,

CONTRACTOR INSTALLED

FA-MN-PA FIRE ALARM AND MASS NOTIFICATION AND PUBLIC

ADDRESS CONTROL PANEL

FEB FIRE EXTINGUISHER BRACKET

FEC FIRE EXTINGUISHER CABINET

MFR MANUFACTURER

MH MOUNTING HEIGHT

MNS MASS NOTIFICATION SYSTEM

NEC NATIONAL ELECTRICAL CODE

NO. NUMBER

SPD SURGE PROTECTIVE DEVICE

TVSS TRANSIENT VOLTAGE SURGE SUPRESSOR

TYP TYPICAL

UL UNDERWRITERS LABORATORY

UOI UNLESS OTHERWISE INDICATED

UON UNLESS OTHERWISE NOTED

W, WP WEATHERPROOF

1. SEE FA601 FOR ADDITIONAL NOTES CONCERNING

THE FIRE ALARM & MASS NOTIFICATION SYSTEM

COMPONENTS AND OPERATIONS.

2. SPEAKER LOCATIONS AND QUANTITIES SHALL BE

ADJUSTED AS NECESSARY TO ACHIEVE THE

SPECIFIED SPEECH INTELLIGIBILITY USING THE

SPEAKERS SUBMITTED FOR APPROVAL. SIMULATION

SOFTWARE SHALL BE USED TO CALCULATE SOUND

QUALITY. VERTICAL STORAGE CAROUSELS SHALL BE

MODELLED IN THE SOFTWARE. SEE SPECIFICATION

SECTION 28 31 76 FOR ADDITIONAL REQUIREMENTS.

3. CONDUITS SHALL BE CONCEALED IN CEILINGS AND

WALLS, EXCEPT AS SHOWN OTHERWISE.

4. MOUNT OUTLET BOXES SO THAT NONE OCCUR

BACK TO BACK IN WALLS.

5. SEAL PENETRATIONS THROUGH FLOORS OR FIRE

WALLS TO MAINTAIN THE INTEGRITY OF THE FIRE

AND ACOUSTIC RATINGS OF THE WALLS AND

FLOORS.

6. RACEWAYS CROSSING STRUCTURAL EXPANSION

JOINTS OR SEISMIC JOINTS SHALL BE PROVIDED

WITH SUITABLE EXPANSION FITTINGS OR OTHER

SUITABLE MEANS TO COMPENSATE FOR THE

BUILDING EXPANSION AND CONTRACTION AND TO

PROVIDE FOR CONTINUITY OF GROUNDING.

7. FOR TYPICAL MOUNTING HEIGHTS, SEE E-001.

FIRE ALARM & MASS NOTIFICATION MATRIX NOTES

1. THE MASS NOTIFICATION SYSTEM SHALL TEMPORARILY

INTERRUPT THE FIRE ALARM AUDIBLE MESSAGE AND

VISUAL NOTIFICATION APPLIANCES DURING

SIMULTANEOUS FIRE AND MASS EVACUATION EVENTS.

ALL OTHER FEATURES OF THE FIRE ALARM SYSTEM

SHALL FUNCTION PROPERLY. DURING THE

INTERRUPTION OF THE FIRE ALARM AUDIBLE AND VISUAL

SIGNALS, A DISTINCT SUPERVISORY SIGNAL SHALL BE

ANNUNCIATED (BOTH AUDIBLY AND VISUALLY) AT THE

FACP (AND REMOTE FIRE ALARM ANNUNCIATORS) AND

SHALL BE TRANSMITTED TO THE CENTRAL FIRE ALARM

SYSTEM.

2. SEE MECHANICAL SHEETS FOR HVAC SHUT-DOWN AND

CARBON MONOXIDE CONTROL DETAILS.

FIRE ALARM MANUAL PULL STATION.

FIRE ALARM MANUAL PULL STATION ON A SEPERATE INITIATION CIRCUIT

EXCLUDED FROM TESTING WHEN THE DETECTION OR SPRINKLER SYSTEM IS

PLACED IN "TEST" MODE. (SEE NFPA 72 PARA A-23.8.5.1.2.)

FIRE ALARM AND MASS NOTIFICATION STROBE (CLEAR) MARKED "ALERT", WALL

MOUNTED. NUMBER INDICATES INTENSITY. WALL MOUNTED 7'-6" AFF OR 6"

BELOW CEILING, WHICHEVER IS LOWER. NUMBER INDICATES CANDELA

RATING. 'WP' INDICATES WEATHERPROOF.

FIRE ALARM/ MASS NOTIFICATION/ PAGING SYSTEM GRILL SPEAKER, CEILING

MOUNTED WHERE APPLICABLE. PENDANT MOUNT AT HEIGHT OF LIGHT

FIXTURES IN SPACES WITH NO CEILINGS.

FIRE ALARM/ MASS NOTIFICATION/ PAGING SYSTEM GRILL SPEAKER, WALL

MOUNTED 7'-6" AFF UON. 'WP' INDICATES WEATHERPROOF.

FIRE ALARM/ MASS NOTIFICATION/ PAGING SYSTEM HORN SPEAKER,

WEATHERPROOF, PENDANT OR WALL MOUNTED AS INDICATED .

KNOX BOX (SEE ARCHITECTURE SHEETS).

HEAT DETECTOR.

SMOKE DETECTOR.

DUCT SMOKE DETECTOR (SEE MECHANICAL SHEETS).

SPRINKLER SYSTEM FLOW SWITCH (SEE FIRE PROTECTION SHEETS).

SPRINKLER SYSTEM TAMPER SWITCH (SEE FIRE PROTECTION SHEETS).

FIRE ALARM & MASS NOTIFICATION & PUBLIC ADDRESS SYSTEM CONTROL

PANEL.

FLUSH MOUNTED FIRE ALARM ANNUNCIATOR PANEL.

FLUSH MOUNTED MASS NOTIFICATION SYSTEM "LOCAL OPERATOR CONSOLE".

FIRE ALARM AND MASS NOTIFICATION TEXTUAL EMERGENCY MESSAGE

DISPLAY, WALL MOUNTED

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\k6enxoaa\Documents\FY18JA76149_RECEPTION COMPLEX_MEP_R18_k6enxoaa.rvt

8/16/2019 10:11:35 AM

JU

N

E

W

2H P1

9R

M . B

R

EN

N

AN

P.

S

U

LL

IV

AN

2-

-0

FA001

FI

R

E

AL

AR

M

L

EG

EN

D

A N

D O

PE

R

AT

IO

N S

M

AT

R

IX

H

AG

O

O D

A

VE

N U

E C

H

AR

LE

ST

O N

D

IS

TR

IC

T C

H

AR

LE

ST

O N

, S O

U

TH

C

AR

O

LI

N A

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

SA

VA

N

N

AH

D

IS

TR

IC

T

W

. O G

LE

TH

O R

PE

A

VE

SA

VA

N N

AH

, G

A

FO

R

T

JA

C

KS

O N

, S O

U

TH

C

AR

O

LI

N A

R

EC

EP

TI

O N

C O

M

PL

EX

P

H

AS

E

FY

8, P

N

VO

LU

M E

-C

LO

TH

IN

G

IN

IT

IA

L

IS

SU

E

PO

IN

T

(C

IIP

T.

F

U N

K

ISSUE FOR CONSTRUCTION

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

E D

IN

A C

C O

R D

A N C

E W

IT

H

A M

E N D

M

EN

T

A U

G

RECESSED VOLUMETRIC

2'X2' LED TROFFER

FEATURES

REFLECTORS: HIGH REFLECTANCE

GLOSS WHITE

SHIELDING: POSITIVELY RETAINED,

ACRYLIC LENS

OPTICS: CONTROLLED HIGH ANGLE LIGHT DISTRIBUTION

FOR VOLUMETRIC ILLUMINATION

SPACING 1.2 PARALLEL (NOMINAL)

CRITERIA: 1.3 PERPENDICULAR (NOMINAL)

GENERAL DESCRIPTION

HOUSING: COLD ROLLED STEEL HOUSING

FINISH: WHITE FINISH; PAINTED AFTER FABRICATION

DIMENSIONS: 24" x 24" x 3.5" (W x L x D)

**SEE LUMINAIRE SCHEDULE FOR LUMENS DELIVERED**

LOW BAY COMMERCIAL LED FIXTURE

FEATURES

SHIELDING: WHITE ACRYLIC

OPTICS: WIDE DISTRIBUTION

OTHER: DESIGNLIGHTS CONSORTIUM

(DLC) QUALIFIED

GENERAL DESCRIPTION

HOUSING: ONE-PIECE LOW-COPPER DIE-CAST ALUMINUM HOUSING

WITH METAL ELECTRICAL ACCESS TRAY

FINISH: FIVE-STAGE POLYESTER POWDER COAT; GRAPHITE

METALLIC FINISH; PAINTED AFTER FABRICATION

DIMENSIONS: AS SHOWN

18"

7"

RECESSED LENSED LED TROFFER

FEATURES

REFLECTORS: HIGH REFLECTANCE

GLOSS WHITE

SHIELDING: FROSTED ACRYLIC

PATTERN #12 (0.125" THICKNESS)

DOOR FRAME: FLAT WHITE ALUMINUM DOOR WITH

MITERED CORNERS

GENERAL DESCRIPTION

HOUSING: COLD ROLLED STEEL HOUSING TRIMMED TO COORDINATE

WITH CEILING, T-SLOT STEEL HINGED DOOR FRAME SECURED

TO HOUSING WITH FULLY ENCLOSED SPRING-LOADED CAM

LATCHES; DRIVER SECURED BY MINIMUM OF TWO BOLTS

FINISH: REFLECTIVE WHITE POLYESTER POWDER COAT BONDED TO

PHOSPHATE-FREE, MULTI-STAGE PRETREATED METAL; PAINTED

AFTER FABRICATION

DIMENSIONS: 24" x 24" x 5" (W x L x D)

OTHER: TRIPLE GASKETED (DOOR FRAME AND HOUSING, DOOR FRAME

AND LENS); DLC QUALIFIED

ENCLOSED AND GASKETED

INDUSTRIAL LED FIXTURE

FEATURES

REFLECTORS: HIGH REFLECTANCE

WHITE

SHIELDING: HIGH IMPACT LINEAR

FROSTED ACRYLIC

LENS

OTHER: FUSED; IP65 RATED;

UL F1 WEATHERABILITY RATED;

DESIGNLIGHTS CONSORTIUM (DLC) QUALIFIED

GENERAL DESCRIPTION

HOUSING: IMPACT RESISTANT, UV STABILIZED, FIBERGLASS

WITH REMOVABLE GEAR TRAY FOR MODULE REPLACEMENT;

NON-POROUS GASKET; STAINLESS STEEL LATCHES

DIMENSIONS: 52"x7"x5" (LxWxD)

EXTERIOR ARCHITECTURAL

LED WALL SCONCE

FEATURES

MOUNTING: SURFACE MOUNTING BRACKET

REFLECTORS: HIGH REFLECTANCE WHITE ENAMEL

DIFFUSER: TEMPERED GLASS

OTHER: FUSED; IP65 RATED; STAINLESS STEEL

HARDWARE; DESIGNLIGHTS CONSORTIUM (DLC) QUALIFIED.

GENERAL DESCRIPTION

HOUSING: SINGLE-PIECE DIE CAST ALUMINUM QUARTERSPHERE HOUSING

WITH A HINGED BACK-PLATE.

FINISH: TEXTURED DARK BRONZE COLOR; EXTERIOR PARTS ARE

PROTECTED BY A SUPER DURABLE TGIC THERMOSET POWDER

FINISH THAT PROVIDES SUPERIOR RESISTANCE TO

CORROSION AND WEATHERING.

DIMENSIONS: W1- 13" x 6-3/4" x 7-3/4" (W x H x D)

DISTRIBUTION: TYPE lV

PUSH-TO-

TEST

AND STATUS

INDICATOR

LOW PROFILE LED

UNDERCABINET TASK LIGHT

FEATURES

SHIELDING: ACRYLIC TEXTURED LENS

TO MINIMIZE LAMP IMAGE

OTHER: INTEGRAL PIR OCCUPANCY SENSOR

(DETECTION DISTANCE NO GREATER

THAN 3 FT; NOMINAL 10 MINUTE TIME DELAY)

GENERAL DESCRIPTION

HOUSING: EXRUDED ALUMINUM HOUSING WITH MATCHING

ALUMINUM OR INJECTION MOLDED POLYCARBONATE

ENDCAPS AND COVERS.

FINISH: WHITE POWDER COAT WITH MULTI-STAGE PHOSPHATE

METAL; ENDCAP COLOR TO MATCH HOUSING

MAXIMUM

DIMENSIONS: 6"x1" (WxD)

LENGTH: LENGTHS VARY; COORDINATE LENGTHS WITH CABINET

FABRICATOR FOR FULL COVERAGE ALONG LENGTH OF

CABINETS

RECESSED LENSED LED TROFFER

FEATURES

REFLECTORS: HIGH REFLECTANCE

GLOSS WHITE

SHIELDING: FROSTED ACRYLIC

PATTERN #12 (0.125" THICKNESS)

DOOR FRAME: FLAT WHITE ALUMINUM DOOR WITH

MITERED CORNERS

GENERAL DESCRIPTION

HOUSING: COLD ROLLED STEEL HOUSING TRIMMED TO COORDINATE

WITH CEILING, T-SLOT STEEL HINGED DOOR FRAME SECURED

TO HOUSING WITH FULLY ENCLOSED SPRING-LOADED CAM

LATCHES; DRIVER SECURED BY MINIMUM OF TWO BOLTS

FINISH: REFLECTIVE WHITE POLYESTER POWDER COAT BONDED TO

PHOSPHATE-FREE, MULTI-STAGE PRETREATED METAL; PAINTED

AFTER FABRICATION

DIMENSIONS: 12" x 48" x 6" (W x L x D)

OTHER: TRIPLE GASKETED (DOOR FRAME AND HOUSING, DOOR FRAME

AND LENS); DESIGNLIGHTS CONSORTIUM (DLC) QUALIFIED

CANOPY LED FIXTURE

FEATURES

SHIELDING: INDIVIDUAL LED

LENSES WITH VANDAL

SHIELD PER EACH LED

MODULE

OPTICS: TYPE V SQUARE

OTHER: DESIGNLIGHTS CONSORTIUM

(DLC) QUALIFIED, IP65, LISTED TO UL 1598 FOR

USE IN WET LOCATIONS

GENERAL DESCRIPTION

HOUSING: DIE-CAST ALUMINUM HOUSING, HORIZONTAL AND

VERTICAL FINS FOR TWO DIRECTIONAL AIR FLOW THAT

MAXIMISES HEAT DISSIPATION

DIMENSIONS: 18" DIAMETER, 5-1/2" HEIGHT

FINISH: COLOR WHITE

RECESSED LED LENS

DOWNLIGHT FIXTURE

FEATURES

BEAM: 45 DEGREE

GENERAL DESCRIPTION

HOUSING: GALVANIZED STEEL MOUNTING FRAME WITH EXPANDABLE

SELF-LOCKING MOUNTING BARS; VERTICALLY ADJUSTABLE

MOUNTING BRACKETS; POST-INSTALLATION ADJUSTMENT

CAPABILITY FROM BELOW CEILING; ALUMINUM HEAT SINK

REFLECTORS: POLYCARBONATE LENS INTEGRAL TO LIGHT ENGINE

FLANGE: SEMI-SPECULAR

DIMENSIONS: 6" NOMINAL APERATURE; 7" HEIGHT

OTHER: UL LISTED FOR WET LOCATIONS; TOOL-LESS REPALACEMENT

OF LED ENGINE FROM BELOW CEILING; IP66 RATED; TOOL-

ESS REPALACEMENT OF LED ENGINE FROM BELOW

HIGH BAY INDUSTRIAL LED FIXTURE

FEATURES

SHIELDING: FROSTED ACRYLIC

MATERIAL

OPTICS: NARROW DISTRIBUTION

OTHER: SAFETY CABLE;

FUSED (TYPE HB);

AMBIENT OPERATION

(55 CELSIUS); EMERGENCY

DRIVER (45 CELSIUS) (TYPE HBE);

DESIGN LIGHTS CONSORTIUM (DLC)

QUALIFIED; HIGH/LOW OPERATION

(2-LEVEL) INTEGRATED OCCUPANCY

AND DAYLIGHT SENSOR

GENERAL DESCRIPTION

HOUSING: CODE GAUGE STEEL CONSTRUCTION HOUSING AND END

PLATES. ALL METAL PARTS ARE POST PAINTED AFTER

FABRICATION WITH POLYESTER POWER COAT PAINT

WITH 90% REFLECTANCE.

DIMENSIONS: 2"x 4" (WxD)

RECESSED LENSED 4-INCH APERTURE LED SLOT LUMINAIRE

FEATURES

REFLECTORS: HIGH REFLECTANCE

GLOSS WHITE

SHIELDING: LOW BRIGHTNESS FLUSH

FROSTED WHITE LENS

GENERAL DESCRIPTION

HOUSING: EXTRUDED ALUMINUM;

FINISH: WHITE POWDER COAT OVER MULTI-STAGE PHOSPHATE

PREPARED METAL; PAINTED AFTER FABRICATION

OTHER: SUITABLE FOR CONTINUOUS STRAGHT RUNS (SEE PLANS)

DIMENSIONS: 4"x48"(WxD)

**SEE LUMINAIRE SCHEDULE FOR LUMENS DELIVERED**

SURFACE MOUNTED

LED ARC SCONCE

FEATURES

REFLECTORS: HIGH REFLECTANCE WHITE ENAMEL

SHIELDING: WHITE ACRYLIC DIFFUSER

GENERAL DESCRIPTION

HOUSING: FRONT PANEL WITH A ROLLED HEAVY GAUGE ALUMINUM

PLATE AND HEAVY GAUGE HOUSING

FINISH: ALUMINUM PAINT

DIMENSIONS: 5" x 24" x 4" (W x H x D)

DESIGN BASIS: SHAPER-AUTOGRAPH COLLECTION LOOP SERIES 866

(APPROVED EQUAL ALLOWED)

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\K6ENXMPB\Documents\FY18JA76149_RECEPTION COMPLEX_MEP_R18_K6ENXMPB.rvt

8/16/2019 11:11:19 AM

JU

N

E

W

2H P1

9R

D . V

AU

G

H N

P.

S

U

LL

IV

AN

2-

-0

EL502

LU

M

IN

AI

R E

D

ET

AI

LS

H

AG

O

O D

A

VE

N U

E C

H

AR

LE

ST

O N

D

IS

TR

IC

T C

H

AR

LE

ST

O N

, S O

U

TH

C

AR

O

LI

N A

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

SA

VA

N

N

AH

D

IS

TR

IC

T

W

. O G

LE

TH

O R

PE

A

VE

SA

VA

N N

AH

, G

A

FO

R

T

JA

C

KS

O N

, S O

U

TH

C

AR

O

LI

N A

R

EC

EP

TI

O N

C O

M

PL

EX

P

H

AS

E

FY

8, P

N

VO

LU

M E

-C

LO

TH

IN

G

IN

IT

IA

L

IS

SU

E

PO

IN

T

(C

IIP

M . B

R

EN

N

AN

ISSUE FOR CONSTRUCTION

TYPES R2L, R2M,R2H, R2LE, R2ME & R2HE6 TYPES S1, S2, S1E & S2E8TYPE R3, R3E, R3M & R3ME7

TYPES S4, SM4, S4E & SM4E9 TYPE W1 & W1E10 TYPE UC12

TYPE R1H & R1HE5

TYPE CS1 TYPE D1, D1E, D2 & D2E2 TYPE HB & HBE3 TYPE L4L, L4M, L4LE & L4ME4

TYPE WS11

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

A U

G

0 1

DESCRIPTION OF OPERATION

1 MANUAL ON/OFF LINE VOLTAGE TOGGLE SWITCHES

AUTO SENSOR ON (100%)

AUTO SENSOR OFF

LIGHTING ROOM CONTROLLER WITH OCCUPANCY

SENSORS.

LIGHTING ROOM CONTROLLER WITH LOW VOLTAGE

WALLSTATIONS AND OCCUPANCY SENSORS. BI-LEVEL

OPERATION. RECEPTACLE CONTROL WHERE

INDICATED.

AUTO SENSOR ON (50%)

MANUAL ON (FULL)

MANUAL ON (HALF)

MANUAL OFF

AUTO SENSOR OFF

AUTO SENSOR ON (50%)

MANUAL ON (HALF)

MANUAL ON (FULL)

MANUAL RAISE/LOWER

MANUAL OFF

AUTO SENSOR OFF

9 LIGHTING ROOM CONTROLLER SYSTEM WITH LOW

VOLTAGE WALLSTATIONS. BI-LEVEL AND MANUAL

DIMMING OPERATION.

S

SLV3

SLV5d

15 MINUTES

15 MINUTES

15 MINUTES

SENSOR TIME

DELAY UOI

STRATEGY REMARKS SWITCHES DESCRIPTION OF OPERATION

AUTO SENSOR ON (50%)

MANUAL ON (30%)

MANUAL ON (FULL)

MANUAL ON (PRESENTATION)(1%)

MANUAL RAISE/LOWER

MANUAL OFF (ALL OFF)

AUTO SENSOR OFF

7 LIGHTING ROOM CONTROLLER WITH OCCUPANCY

SENSORS AND LOW VOLTAGE WALLSTATIONS. TRI-

LEVEL AND MANUAL DIMMING OPERATION.

SLV6d 15 MINUTES

SENSOR TIME

DELAY UOI

STRATEGY REMARKS SWITCHES

LIGHTING ROOM CONTROLLER WITH OCCUPANCY

SENSORS.

UPON FIRE ALARM ACTIVATION, CONTROLS SHALL BE

OVERRIDEN AND LUMINAIRES SHALL BE FORCED ON.

AUTO SENSOR ON

OCCUPANCY: LIGHTING AT 100%

VACANCY: LIGHTING AT 0%

FIRE ALARM ON (BYPASS CONTROL DEVICES)

FACP ALARM SIGNAL

FULL LIGHT OUTPUT

2 15 MINUTES

LINE VOLTAGE SENSOR SWITCHESAUTO SENSOR ON (100%)

MANUAL OFF

AUTO SENSOR OFF

5 Sos 15 MINUTES

AUTO SENSOR ON (50%)

MANUAL ON (FULL)

MANUAL OFF

AUTO SENSOR OFF

6 LIGHTING ROOM CONTROLLER WITH LOW VOLTAGE

WALLSTATIONS AND OCCUPANCY SENSORS. BI-LEVEL

OPERATION.

SLV2 15 MINUTES

OCCUPANCY SENSOR AND DAYLIGHT SENSOR

INTEGRAL TO LUMINAIRE. DAYLIGHT SENSOR SHALL

OVERRIDE THE OCCUPANCY SENSOR TARGET

ILLUMINATION LEVEL WHEN THE OCCUPANCY

SENSOR IS IN OCCUPIED MODE.

LUMINAIRES SHALL BE ROUTED THROUGH THE

LIGHTING CONTROL PANEL (LCP) WITH INTEGRAL

ASTRONOMICAL CLOCK. MANUAL ON CONTROL SHALL

BE VIA LOW VOLTAGE WALLSTATIONS. LUMINAIRES

WILL SWEEP-OFF VIA THE TIME CLOCK WITH FIVE

MINUTE BLINK WARNING. OVERRIDE CAPABILITY

SHALL BE PROVIDED DURING NON-DUTY HOURS. BI-

LEVEL OPERATION.

UPON FIRE ALARM ACTIVATION, LIGHTING CONTROL

PANEL RELAYS SHALL BE CLOSED AND LUMINAIRES

SHALL BE FORCED ON. SENSORS INTEGRAL TO

LUMINAIRES SHALL REMAIN OPERATIONAL.

8 SLCP 15 MINUTESDUTY HOURS (0600-1900)

ZONED MANUAL ON (50%)

LUMINAIRE AUTO SENSOR ON/DIM

OCCUPANCY: 100%

VACANCY: 30%

SWEEP OFF VIA TIME CLOCK (1900)

NON-DUTY HOURS (1900-0600)

ZONED MANUAL ON 2-HR OVERRIDE (50%)

LUMINAIRE AUTO SENSOR ON/DIM

OCCUPANCY: 100%

VACANCY: 30%

ZONED MANUAL OFF

SWEEP OFF VIA TIME CLOCK (2 HR)

FIRE ALARM ON (BYPASS LCP CONTROL INPUTS)

FACP ALARM SIGNAL

FULL LIGHT OUTPUT

AUTO SENSOR ON/OFF, PHOTOCELL OVERRIDE.

VACANCY: LIGHTING AT 30%

OCCUPANCY: LIGHTING AT 100%

15 MINUTESINTEGRAL COMBINATION OF MOTION SENSOR AND

PHOTOCELL TO LUMINAIRE.

LIGHTING ROOM CONTROLLER(S) WITH LOW VOLTAGE

WALLSTATIONS. BI-LEVEL OPERATION.

ZONE 1 = PASSAGE, STEAM PRESS 149 & TAILORING 150.

ZONE 2 = TAILORING 150.

ZONE 3 = STEAM PRESS 149.

13 SLV3a 15 MINUTES

AUTO SENSOR ON (50%)

ZONE 1,2,3&4

MANUAL ON (FULL)

ZONE 1

ZONE 2

ZONE 3

ZONE 4

MANUAL OFF (ALL OFF)

ZONE 1,2,3&4

AUTO SENSOR OFF

ZONE 1,2,3&4

15 MINUTESSLV5z

AUTO SENSOR ON (50%)

ZONE 1

ZONE 2

ZONE 3

MANUAL ON (FULL)

ZONE 1

ZONE 2

ZONE 3

MANUAL OFF

ZONE 2

ZONE 3

AUTO SENSOR OFF

ZONE 1

ZONE 2

ZONE 3

LIGHTING ROOM CONTROLLER(S) WITH LOW VOLTAGE

WALLSTATIONS AND OCCUPANCY SENSORS. BI-LEVEL

OPERATION.

ZONE 1 = PERIMETER LIGHTING, PHASE 2 ISSUE 139.

ZONE 2 = WEST AISLE LIGHTING, PHASE 2 ISSUE 139.

ZONE 3 = EAST AISLE LIGHTING, PHASE 2 ISSUE 139.

ZONE 4 = CENTER AISLE LIGHTING, PHASE 2 ISSUE 139.

LIGHTING ROOM CONTROLLER(S) WITH LOW VOLTAGE

WALLSTATIONS. BI-LEVEL OPERATION.

14 SLV3z 15 MINUTESAUTO SENSOR ON (50%)

ZONE 1&2

MANUAL ON (FULL)

ZONE 1

ZONE 2

MANUAL OFF (ALL OFF)

ZONE 1&2

ZONE 2

AUTO SENSOR OFF

ZONE 1&2

SLV3b

10 AUTO SENSOR ON (50%)

MANUAL ON (ENTER)

ZONE 1: 30%

ZONE 2: 100%

ZONE 3: 100%

MANUAL (GENERAL)

ZONE 1,2&3: 100%

MANUAL ON (LECTURE)

ZONE 1: 10%

ZONE 2: 100%

ZONE 3: 30%

MANUAL ON (AV MODE)

ZONE 1: 1%

ZONE 2: OFF

ZONE 3: OFF

MANUAL (RAISE)

ZONE 1,2&3: RAISE TO 100%

MANUAL (LOWER)

ZONE 1,2&3: LOWER TO OFF

LIGHTING ROOM CONTROLLER(S) WITH OCCUPANCY

SENSORS AND LOW VOLTAGE WALLSTATIONS. MULTI-

SCENE AND MANUAL DIMMING OPERATION.

SLV6dz 15 MINUTES

(SEE EL602)

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\K6ENXMPB\Documents\FY18JA76149_RECEPTION COMPLEX_MEP_R18_K6ENXMPB.rvt

8/16/2019 10:36:07 AM

JU

N

E

W

2H P1

9R

D . V

AU

G

H N

P.

S

U

LL

IV

AN

2-

-0

EL601

LI

G

H

TI

N G

C O

N

TR

O L

ST

R

AT

EG

Y

SC

H

ED

U

LE

H

AG

O

O D

A

VE

N U

E C

H

AR

LE

ST

O N

D

IS

TR

IC

T C

H

AR

LE

ST

O N

, S O

U

TH

C

AR

O

LI

N A

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

SA

VA

N

N

AH

D

IS

TR

IC

T

W

. O G

LE

TH

O R

PE

A

VE

SA

VA

N N

AH

, G

A

FO

R

T

JA

C

KS

O N

, S O

U

TH

C

AR

O

LI

N A

R

EC

EP

TI

O N

C O

M

PL

EX

P

H

AS

E

FY

8, P

N

VO

LU

M E

-C

LO

TH

IN

G

IN

IT

IA

L

IS

SU

E

PO

IN

T

(C

IIP

M . B

R

EN

N

AN

ISSUE FOR CONSTRUCTION

LIGHTING CONTROL STRATEGIES NOTES:

1. ALL LIGHT FIXTURES IN THE SAME ROOM OR ZONE SHALL BE CONTROLLED BY ALL OCCUPANCY SENSORS AND SWITCHES IN

ITS RESPECTIVE ROOM OR ZONE UNLESS OTHERWISE INDICATED.

2. LIGHTING CONTROL PANELS, LIGHTING ROOM CONTROLLER SYSTEMS SHALL INCLUDE ALL FEATURES, COMPONENTS AND

ACCESSORIES REQUIRED TO ACCOMPLISH THE LIGHTING CONTROL STRATEGIES.

3. RECEPTACLES DENOTED WITH A SUBSCRIPT 'S' ON EP SERIES SHALL BE CONTROLLED BY OCCUPANCY SENSOR VIA ROOM CONTROLLER. ALL RECEPTACLES IN THE SAME ROOM SHALL BE CONTROLLED BY ALL OCCUPANCY SENSORS IN ITS

RESPECTIVE ROOM UNLESS OTHERWISE INDICATED.

4. VERIFY THE USER'S DUTY HOURS WITH THE CONTRACTING OFFICER'S REPRESENTATIVE

(COR) PRIOR TO PROGRAMMING THE INITIAL SETTINGS IN THE LCP.

5.EACH RELAY IN THE LIGHTING ROOM CONTROLLER SHALL CONTROL ONLY ONE ZONE. WHERE THE NUMBER OF ZONES IN A CONTROL SPACE EXCEEDS THE NUMBER OF RELAYS IN THE LIGHTING ROOM CONTROLLER, ADDITIONAL ROOM CONTROLLERS SHALL BE PROVIDED. LIGHTING ROOM CONTROLLERS SHALL BE CAPABLE OF BEING CONNECTED TOGETHER AND SHARE INFORMATION. CONNECTIONS BETWEEN LIGHTING ROOM CONTROLLERS SHALL BE IN ACCORDANCE WITH THE

MANUFACTURER'S RECOMMENDATION.

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

A U

G

0 1

RELAY

No. POLES CIRCUIT DESCRIPTION OF LOAD SWITCH LOAD VOLTAGE

1 HL2-1 WAREHOUSE 156 SLCP 277V, 1-PH

SLCPWAREHOUSE 156

SLCPWAREHOUSE 156

1 HL2-3 277V, 1-PH

1 HL2-5 277V, 1-PH

LCP RELAY SCHEDULE

4 1 5 1

SLCP

SLCP

277V, 1-PH

277V, 1-PH

HL2-7

HL2-9

WAREHOUSE 156

WAREHOUSE 156

CONTROLLED ZONE

A B C D

6 1 SLCP 277V, 1-PHHL2-11 WAREHOUSE 156

7 1 SLCP 277V, 1-PHHL2-13 WAREHOUSE 156

E F

G

RELAY 1

(QTY AS SHOWN ON PLANS)

LCP RM 137

HL2-10

HL2-13 H

N

RELAY 3

RELAY 4

RELAY 5

RELAY 6

RELAY 7

RELAYS 8-16

(SPARES)

LCPSLCPS

FACP

LUMINAIRES

(QTY AS SHOWN ON PLANS)

CONTROLLED

ZONE G

(ROOM 156)

H N

SW

UNSWITCHED (HOT)

NEUTRAL

SWITCHED

LUMINAIRES

(QTY AS SHOWN ON PLANS)

CONTROLLED

ZONE F

(ROOM 156)

H N

SW

UNSWITCHED (HOT)

NEUTRAL

SWITCHED

LUMINAIRES

(QTY AS SHOWN ON PLANS)

CONTROLLED

ZONE E

(ROOM 156)

H N

SW

UNSWITCHED (HOT)

NEUTRAL

SWITCHED

LUMINAIRES

(QTY AS SHOWN ON PLANS)

CONTROLLED

ZONE D

(ROOM 156)

H N

SW

UNSWITCHED (HOT)

NEUTRAL

SWITCHED

LUMINAIRES

(QTY AS SHOWN ON PLANS)

CONTROLLED

ZONE C

(ROOM 156)

H N

SW

UNSWITCHED (HOT)

NEUTRAL

SWITCHED

LUMINAIRES

(QTY AS SHOWN ON PLANS)

CONTROLLED

ZONE B

(ROOM 156)

H N

SW

UNSWITCHED (HOT)

NEUTRAL

SWITCHED

LUMINAIRES

(QTY AS SHOWN ON PLANS)

CONTROLLED

ZONE A

(ROOM 156)

H N

SW

UNSWITCHED (HOT)

NEUTRAL

SWITCHED

RELAY 2

HL2-11 H

N

HL2-9 H

N

HL2-7 H

N

HL2-5 H

N

HL2-3 H

N

HL2-1 H

N

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\K6ENXMPB\Documents\FY18JA76149_RECEPTION COMPLEX_MEP_R18_K6ENXMPB.rvt

8/16/2019 10:36:18 AM

JU

N

E

W

2H P1

9R

D . V

AU

G

H N

P.

S

U

LL

IV

AN

2-

-0

EL603

LI

G

H

TI

N G

C O

N

TR

O L

D

IA

G R

AM

S

H

AG

O

O D

A

VE

N U

E C

H

AR

LE

ST

O N

D

IS

TR

IC

T C

H

AR

LE

ST

O N

, S O

U

TH

C

AR

O

LI

N A

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

SA

VA

N

N

AH

D

IS

TR

IC

T

W

. O G

LE

TH

O R

PE

A

VE

SA

VA

N N

AH

, G

A

FO

R

T

JA

C

KS

O N

, S O

U

TH

C

AR

O

LI

N A

R

EC

EP

TI

O N

C O

M

PL

EX

P

H

AS

E

FY

8, P

N

VO

LU

M E

-C

LO

TH

IN

G

IN

IT

IA

L

IS

SU

E

PO

IN

T

(C

IIP

M . B

R

EN

N

AN

ISSUE FOR CONSTRUCTION

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

A U

G

0 1

LCP RELAY SCHEDULES2LCP SINGLE LINE DIAGRAM1

SLVx

OS OS

SLVx

INPUT DEVICES AS

SHOWN ON PLANS OR

REQUIRED BY

CONTROL

STRATEGIES)

ROOM

CONTROLLER

277 VAC

LIGHTING CKT

FROM PANEL

LOW

VOLTAGE

LIGHTING FIXTURES AS

SHOWN ON PLANS. SEE

LIGHTING PLANS FOR LIGHTING

ZONES WHEN APPLICABLE.

ZONE 1 ZONE 2

SEE EL601 FOR

APPLICABLE

STRATEGY

FACP

SLVx

OS OS

SLVx

INPUT DEVICES AS

SHOWN ON PLANS OR

REQUIRED BY

CONTROL

STRATEGIES)

ROOM

CONTROLLER

277 VAC

LIGHTING CKT

FROM PANEL

LOW

VOLTAGE

(QUANTITIES AS REQUIRED)

RECEPTACLE SWITCH PACKS

120 VAC

POWER CKT

FROM PANEL

CONTROLLED

RECEPTACLES

LIGHTING FIXTURES AS

SHOWN ON PLANS. SEE

LIGHTING PLANS FOR LIGHTING

ZONES WHEN APPLICABLE.

ZONE 1 ZONE 2

SEE EL601 FOR

APPLICABLE

STRATEGY

FACP

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\K6ENXMPB\Documents\FY18JA76149_RECEPTION COMPLEX_MEP_R18_K6ENXMPB.rvt

8/16/2019 10:36:27 AM

JU

N

E

W

2H P1

9R

D . V

AU

G

H N

P.

S

U

LL

IV

AN

2-

-0

EL604

LI

G

H

TI

N G

C O

N

TR

O L

D

IA

G R

AM

S

SA

VA

N N

AH

D

IS

TR

IC

T

C H

AR

LE

ST

O

N , S

O U

TH

C

AR

O

LI

N

A

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

SA

VA

N

N

AH

D

IS

TR

IC

T

W

. O G

LE

TH

O R

PE

A

VE

SA

VA

N N

AH

, G

A

FO

R

T

JA

C

KS

O N

, S O

U

TH

C

AR

O

LI

N A

R

EC

EP

TI

O N

C O

M

PL

EX

P

H

AS

E

FY

8, P

N

VO

LU

M E

-C

LO

TH

IN

G

IN

IT

IA

L

IS

SU

E

PO

IN

T

(C

IIP

M . B

R

EN

N

AN

ROOM CONTROLLER SINGLE LINE DIAGRAM1 ROOM CONTROLLER SINGLE LINE DIAGRAM WITH CONTROLLED RECEPTACLES2

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

A U

G

0 1

NOTES, COMMUNICATIONS:

1. ALL TELECOMMUNICATIONS WORK SHALL BE IN ACCORDANCE WITH UFC 3-580-01, I3A TC, ANSI/TIA

STANDARDS, AND THE NATIONAL ELECTRICAL CODE.

2. TELECOMMUNICATIONS OUTLET CABLING SHALL BE RATED CATEGORY 6 PER ANSI/TIA 568-C.2 STANDARD.

ALL CAT 6 CONNECTIONS SHALL BE TERMINATED TO PIN/PAIR ASSIGNMENT T568B.

3. FOR CATEGORY 6 CABLING, A MINIMUM OF 10 FEET OF CABLE SLACK SHALL BE PROVIDED AT THE COMMUNICATIONS ROOM AND A MINIMUM OF 3 FEET OF CABLE SLACK SHALL BE PROVIDED IN THE SUSPENDED CEILING FOR THE TELECOMMUNICATIONS OUTLET. THE REQUIRED CABLE SLACK LENGTHS ARE IN ADDITION TO THE TOTAL CABLE LENGTHS REQUIRED TO REACH THE TELECOMMUNICATIONS OUTLETS.

LENGTHS SHALL NOT EXCEED 295 FT WHERE 295 FT REPRESENTS THE TOTAL LENGTH OF CABLE INCLUDING

HORIZONTAL, VERTICAL, AND BEND DISTANCES.

4. ALL CONDUIT TO TELECOMMUNICATIONS FLOOR BOXES SHALL BE A MINIMUM OF 1-1/2" UNLESS OTHERWISE INDICATED. TELECOMMUNICATIONS WIRING PLACED UNDER THE SLAB SHALL BE RATED FOR WET LOCATIONS.

5. BACK-TO-BACK OUTLET BOXES SHALL BE SPACED NOT LESS THAN 16" ON CENTER.

6. ALL CONDUIT TO COMMUNICATIONS OUTLET BOXES SHALL BE A MINIMUM OF 1" EMT UNLESS OTHERWISE INDICATED. CONDUITS SHALL BE CONCEALED ABOVE CEILINGS AND IN WALLS, EXCEPT IN UNFINISHED UTILITY

ROOMS. OR AS INDICATED.

7. PULL BOXES SHALL BE PLACED IN CONDUIT RUNS WHERE A CONTINUOUS CONDUIT LENGTH EXCEEDS 100 FEET, OR WHERE THERE ARE MORE THAN TWO 90 DEGREE BENDS. PULL BOXES SHALL BE PLACED IN STRAIGHT, ALIGNED RUNS OF CONDUIT AND NOT BE USED IN LIEU OF A BEND. PULLBOXES SHALL BE

DIRECTLY ACCESSIBLE.

8. ALL COMMUNICATIONS CABLE TRAY, CONDUITS, AND WIRING SHALL BE INSTALLED AND ROUTED IAW UFC 3-580-01. CABLE TRAYS SHALL NOT BE USED TO RUN CABLING FOR THE PUBLIC ADDRESS, IP CAMERA SYSTEM, CATV, FIRE ALARM, OR RADIO FREQUENCY CABLING. EXCEPTIONS ARE CAT 5e, CAT 6, AND FIBER

OPTIC CABLING USED FOR BUILDING AUTOMATION SYSTEMS.

9. RACEWAYS CROSSING STRUCTURAL EXPANSION JOINTS OR SEISMIC JOINTS SHALL BE PROVIDED WITH SUITABLE EXPANSION FITTINGS OR OTHER SUITABLE MEANS TO COMPENSATE FOR THE BUILDING EXPANSION AND CONTRACTION ASURING THE CONTINUITY OF GROUNDING. SEE STRUCTURAL DRAWINGS FOR JOINT

LOCATIONS.

9. PROVIDE PIPE SLEEVES FOR POWER AND COMMUNICATIONS ENTRANCE AND EXIT CONDUITS THROUGH SLABS AT THE TIME OF THE CONSTRUCTION OF THE SLAB. NO DRILLING OR PUNCHING THROUGH SLABS WILL

BE ALLOWED.

11. SEAL PENETRATIONS THROUGH FLOORS AND FIRE WALLS TO MAINTAIN THE INTEGRITY OF THE FIRE AND

ACOUSTIC RATINGS OF THE WALLS AND FLOORS.

12. LAN ELECTRONICS SHALL BE GOVERNMENT-FURNISHED, GOVERNMENT-INSTALLED EQUIPMENT. ALL OTHER EQUIPMENT, CABLING, AND COMPONENTS NECESSARY TO PROVIDE A COMPLETE AND FULLY FUNCTIONAL TELECOMMUNICATIONS SYSTEM (INCLUDING BUT NOT LIMITED TO PATCH PANELS, 110 BLOCKS, PROTECTED ENTRANCE TERMINALS, PATCH CABLES, LINE INTERFACE UNITS, CROSS-CONNECT CABLES, RISER CABLES, FLOOR MOUNTED RACKS, J-HOOKS, HARDWARE, AND HORIZONTAL AND VERTICAL CABLE MANAGEMENT SYSTEMS) SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR TO PROVIDE A COMPLETE AND FULLY FUNCTIONAL TELECOMMUNICATIONS SYSTEM. TESTING REQUIREMENTS SHALL BE IN ACCORDANCE WITH ANSI/TIA STANDARDS AND THE SPECIFICATIONS, AND SHALL BE COMPLETED BY THE CONTRACTOR AND APPROVED BY THE COMMISSIONING AGENT THROUGH THE CONTRACTING OFFICER'S

REPRESENTATIVE (COR).

13. A MINIMUM OF 36 INCHES OF SPACE SHALL BE PROVIDED BOTH IN FRONT OF AND BEHIND THE RACK AND BEHIND ANY INSTALLED EQUIPMENT. A MINIMUM SIDE CLEARANCE OF 24 INCHES SHALL BE PROVIDED ON THE END OF THE RACKS. PROVIDE 100 PERCENT SPARE RACK CAPACITY BASED ON THE AMOUNT OF RACK

CAPACITY UTILIZED BY THE PATCH PANELS PROVIDED.

14. SEE ELECTRICAL LEGEND AND NOTES FOR TYPICAL DEVICE MOUNTING HEIGHTS

15. THE TELEPHONE SYSTEM SHALL CALL-IN INPUT VIA AN INTEGRAL ZONED TELEPHONE PAGING INTERFACE MODULE. ACTIVATION OF THE TELEPHONE PAGING MODULE SHALL TRANSMIT THE VOICE INPUT THROUGH

THE MASS NOTIFICATION SPEAKERS.

NOTES, CATV:

1. THE CONTRACTOR SHALL PROVIDE CATV AMPLIFIERS, SPLITTERS, COMBINERS, LINE TAPS, CABLES, OUTLETS, TILT COMPENSATORS, AND ALL OTHER PARTS, COMPONENTS, AND EQUIPMENT NECESSARY TO

PROVIDE A COMPLETE AND USABLE CATV SYSTEM.

2. THE CATV SYSTEM SHALL PROVIDE A HIGH-QUALITY SIGNAL TO ALL OUTLETS WITH A RETURN PATH FOR

INTERACTIVE TELEVISION AND CABLE MODEM ACCESS.

3. THE CATV SYSTEM SHALL OPERATE WITHIN THE 5 TO1000 MHz BANDWIDTH USING 1000 MHZ PASSIVE DEVICES AND A MINIMUM OF 750 MHz ACTIVE DEVICES.

4. EACH CATV OUTLET SHALL HAVE A MINIMUM SIGNAL LEVEL OF 0 DECIBEL MILLIVOLTS (dBmV)(1000 MICROVOLTS) AND A MAXIMUM OF 15 dBmV AT 55 AND 750 MHz.

CABLE

GAUGE

CABLE SIZE

CABLE NUMBER

CABLE COUNT

100 PR 24 AWG

CA01 301-400

LABELING SHALL COMPLY WITH ANSI/TIA 606 SERIES.

COMMUNICATION LABELING SCHEME

SINGLE ANALOG TELECOMMUNICATIONS OUTLET WITH (1) CATEGORY 6, 8P8C

CONNECTOR. "WP" INDICATES OUTLET TO BE IN A NEMA 4X, NON-METALLIC, GRAY,

WEATHERPROOF ENCLOSURE. MH = 54" AFF UOI.

QUAD OUTLET WITH (2) CATEGORY 6, 8P8C (RJ45 TYPE) CONNECTORS: (1) VOICE, (1)

DATA, AND (2) BLANK SPACES. MH = 18" AFF UOI.

2D - DENOTES QUAD OUTLET WITH (3) CATEGORY 6, 8P8C (RJ45 TYPE)

CONNECTORS: (1) VOICE, (2) DATA, AND (1) BLANK SPACE FOR WORK

STATIONS.

WP - DENOTES GF IN WEATHER PROOF HOUSING, UOI

T1 - DENOTES TELECOMMUNICATIONS CABLING TERMINATION LOCATIONS

T1 TERMINATES IN TER 1, T2 TERMINATES IN TER 2, T3 TERMINATES IN TER 3,

T4 TERMINATES IN TER 4.

QUAD OUTLET WITH (2) CATEGORY 6, 8P8C (RJ45 TYPE) CONNECTORS: (2) DATA, AND

(2) BLANK SPACES. MH = 18" AFF UOI.

COMBINATION POWER AND TELECOMMUNICATIONS FLOOR BOX. QUAD FLOOR

OUTLET WITH (3) CATEGORY 6, 8P8C (RJ45 TYPE) CONNECTORS: (1) VOICE, (2) DATA,

AND (1) BLANK SPACE FOR WORK STATIONS. MH = FLUSH WITH FLOOR. SEE SHEET

EP501 FOR DETAIL.

COMBINATION POWER AND TELECOMMUNICATIONS FLOOR BOX. QUAD FLOOR

OUTLET WITH (2) CATEGORY 6, 8P8C (RJ45 TYPE) CONNECTORS: (2) DATA, AND (2)

BLANK SPACES. MH = FLUSH WITH FLOOR. SEE SHEET EP501 FOR DETAIL.

CEILING MOUNTED DATA TELECOMMUNICATIONS OUTLET WITH (2) 8-PIN MODULAR

JACKS FOR GFGI WIRELESS ACCESS POINTS. CABLING FOR WAP'S SHALL BE CAT 6A

RATED. PENDANT MOUNT AT HEIGHT OF LIGHT FIXTURES IN SPACES WITH NO

CEILINGS.

DUPLEX TELECOMMUNICATIONS OUTLET WITH (1) CATEGORY 6, 8P8C (RJ45 TYPE)

CONNECTORS AND (1) BLANK POSITIONS FOR TV DATA CONNECTION. MH = 80" AFF

UOI.

CATV OUTLET WITH (1) "F" CONNECTOR AND (1) CATEGORY 6, 8P8C (RJ45 TYPE)

CONNECTOR. MH = 72" AFF UOI.

3/4" A-C, VOID-FREE, FIRE-RETARDANT PLYWOOD BACKBOARD WITH NO ADDED UREA

FORMALDEHYDE. SEE SPECIFICATION 01 33 29 FOR FOREST STEWARDSHIP COUNCIL

(FSC) CERTIFICATION REQUIREMENTS.

7-FT, 19-INCH ALUMINUM RACK WITH VERTICAL WIRE MANAGEMENT ASSEMBLY.

CABLE TRAY, TYPE AND SIZE AS INDICATED.

TELECOMMUNICATIONS MAIN GROUND BAR, MH 18" AFF.

TELECOMMUNICATIONS GROUND BAR, MH 18" AFF.

JUNCTION BOX, WALL MOUNTED, MH 18" AFF UOI.

JUNCTION BOX, MOUNTED ABOVE CEILING UOI.

THROUGH WALL CONDUIT SLEEVE.

THROUGH FLOOR STUB UP OR CONDUIT SLEEVE.

COMMUNICATIONS LEGEND GENERAL NOTES

WP

001 - 002 - 001

PP1

OUTLET ROOM #

PORT #

RM 101

SPECIAL CIRCUITS (I.E.- FACP, IDS, ELEV,

ETC.) ARE TO BE LOCATED ON THE FIRST

DATA PATCH PANEL AND ARE TO UTILIZE THE

LAST PORTS OF THE LAST MODULE.

FACP

PATCH PANEL #

CLOSET

FLOOR

BUILDING

NUMBER

BACKBONE CABLES LABELING SCHEME

CABLE

TYPE

CABLE SIZE

CABLE NUMBER

CABLE COUNT

TERMINATION

LOCATIONS

TR1 - TR2

12 FIBER SM

FC01 1-12

TERMINATION

LOCATIONS

TR1 - TR2

PATCH PANELS LABELING SCHEME

OUTLETS LABELING SCHEME

TV

ACS ACCESS CONTROL SYSTEM

AFF ABOVE FINISHED FLOOR

BET BUILDING ENTRANCE TERMINAL

C CONDUIT

CATV CABLE TELEVISION

CKT CIRCUIT

CFCI CONTRACTOR-FURNISHED,

CONTRACTOR-INSTALLED

COR CONTRACTING OFFICER'S

REPRESENTATIVE

CU COPPER

DVI DIGITAL VIDEO INPUT

FACP FIRE ALARM CONTROL PANEL

GFCI GOVERNMENT-FURNISHED,

GOVERNMENT-INSTALLED

GFCI GROUND FAULT CIRCUIT

INTERRUPTER

GFGI GOVERNMENT-FURNISHED,

GOVERNMENT-INSTALLED

G GROUND

GND GROUND

ABBREVIATIONS

J

TMGB

TGB

J

003 - 14 - 03-06

PORTS

PANEL

RACK

HZ HERTZ

IDS INTRUSION DETECTION SYSTEM

MFR MANUFACTURER

MH MOUNTING HEIGHT

MNS MASS NOTIFICATION SYSTEM

MTD MOUNTED

NEC NFPA 70, NATIONAL ELECTRICAL CODE

NO NUMBER

NTS NOT TO SCALE

PP PATCH PANEL

PET PROTECTED ENTRANCE TERMINAL

SPD SURGE PROTECTIVE DEVICE

TVSS TRANSIENT VOLTAGE SURGE

SUPPRESSOR

TYP TYPICAL

UL UNDERWRITERS LABORATORY

UOI UNLESS OTHERWISE INDICATED

UON UNLESS OTHERWISE NOTED

W, WP WEATHERPROOF

2D

TV

T1

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\k6enxoaa\Documents\FY18JA76149_RECEPTION COMPLEX_MEP_R18_k6enxoaa.rvt

8/16/2019 10:11:51 AM

JU

N

E

W

2H P1

9R

D . V

AU

G

H N

P.

S

U

LL

IV

AN

2-

-0

TN001

TE

LE

C O

M M

U N

IC

AT

IO

N

S

LE

G

EN

D A

N D

G

EN

ER

AL

N O

TE

S

H

AG

O

O D

A

VE

N U

E C

H

AR

LE

ST

O N

D

IS

TR

IC

T C

H

AR

LE

ST

O N

, S O

U

TH

C

AR

O

LI

N A

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

SA

VA

N

N

AH

D

IS

TR

IC

T

W

. O G

LE

TH

O R

PE

A

VE

SA

VA

N N

AH

, G

A

FO

R

T

JA

C

KS

O N

, S O

U

TH

C

AR

O

LI

N A

R

EC

EP

TI

O N

C O

M

PL

EX

P

H

AS

E

FY

8, P

N

VO

LU

M E

-C

LO

TH

IN

G

IN

IT

IA

L

IS

SU

E

PO

IN

T

(C

IIP

M . B

R

EN

N

AN

ISSUE FOR CONSTRUCTION

TELECOMMUNICATIONS LEGEND AND GENERAL NOTES1

(SOME ITEMS MAY NOT BE USED)

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

E D

IN

A C

C O

R D

A N C

E W

IT

H

A M

E N D

M

EN

T

A U

G

GROSS BUILDING AREA = 99,539 SF

SHOES MALE

PLATFORM

RUNNING

SHOES

STAGE

BOOT

PLATFORM

SHIRTS

ASU

COATS

RAINCOATS

BERETS

INSIGNIA

GLOVES

BARRACKS

BAG

TOWELS

L.S.

PT SHIRT

PT TRUNKS

S.S.

PT SHIRT

CAPS PPRO UWEAR

FEMALE

PANTS

FEMALE

SHIRTS

MALE

PANTS

MALE

SHIRTS

PLATFORM

EL. -4'-0"

EL. -3'-0"

EL. +4'-0"

254.38 SF

VERTICAL

CAROUSEL

PLATFORM

FLOW

RACKS

FLOW

RACKS

FLOW

RACKS

SHOES FEMALE

PLATFORM

FLOW

RACKS

FLOW

RACKS

BLOUSES

FLOW

RACKS

FLOW

RACKS

BERETS

INSIGNIA

GLOVES

VERTICAL

CAROUSEL

VERTICAL

CAROUSEL

VERTICAL

CAROUSEL

VERTICAL

CAROUSEL

VERTICAL

CAROUSEL

ASU

COATS

RAINCOATS

FLOW

RACKS

FLOW

RACKS

FLOW

RACKS

FLOW

RACKS

FLOW

RACKS

FLOW

RACKS

DUFFLES

(42 SEATS)

SYNTH.

CAPS

(40 SEATS)

VERTICAL

CAROUSEL

(360 PR)

VERTICAL

CAROUSEL

(360 PR)

GLOVES

FLOW

RACKS

FLOW

RACKS

FLOW

RACKS

FLOW

RACKS

FLOW

RACKS

FLOW

RACKS

FLOW

RACKS

FLOW

RACKS

ASU

COATS

ASU

COATS

FLOW

RACKS

MOBILE

CARTS

MOBILE

CARTS

VERTICAL

CAROUSEL

(360 PR)

VERTICAL

CAROUSEL

(360 PR)

SOCKS

FLOW

RACKS

FLOW

RACKS

FLOW

RACKS

FLOW

RACKS

FLOW

RACKS

MOBILE

CARTS

MOBILE

CARTS

FEMALE

SHIRTS

MOBILE

CARTS

VERTICAL

CAROUSEL

(360 PR)

MOBILE

CARTS

MOBILE

CARTS

(20 SEATS)

COVERED FORMATION AREA

MALE ISSUE FEMALE ISSUE

5215.18 SF

4390.71 SF

1363.49 SF

1960.43 SF

2812.33 SF

8600.47 SF

3934.62 SF

(192 PNS) (96 PNS)

28,671.96 SF

SHIPPING &

RECEIVING

MHE STORAGE

CHARGING STATIONS

CARDBOARD

CRUSHERS

RFID

CARDBOARD TRAILER

BI-LEVEL

TRUCK DOCK

(9,203.2 / 2 = 4,601.6 SF)

2968.64 SF

2890.27 SF

CARDBOARD TRAILER

ATM

KIOSK

PAY

PHONES

PAY

PHONES

BULK SECURE STORAGE

2393.79 SF

196.33 SF

MATCH LINE

3934.62 SF

MOBILE

CARTS

SEWING

MACHINE

SEWING

MACHINE

SEWING

MACHINE

SO

R

TI

N

G B

IN

S

IN

SP

EC

TI

O N

SEWING

MACHINE

SEWING

MACHINE

SEWING

MACHINE

SEWING

MACHINE

SEWING

MACHINE

SEWING

MACHINE

SEWING

MACHINE

SEWING

MACHINE

SEWING

MACHINE

SEWING

MACHINE

SEWING

MACHINE

SEWING

MACHINE

SEWING

MACHINE

SEWING

MACHINE

SEWING

MACHINE

SEWING

MACHINE

SEWING

MACHINE

SEWING

MACHINE

PANTS CUTTERS SEWING

MACHINE

IN

SP

EC

TI

O N

SO

R

TI

N

G B

IN

S

SEWING

MACHINE

SEWING

MACHINE

SEWING

MACHINE

SEWING

MACHINE

SEWING

MACHINE

SEWING

MACHINE

SEWING

MACHINE

SEWING

MACHINE

STEAM

PRESS

STEAM

PRESS

STEAM

PRESS

BI

N

BI

N

BI

N

BI

N

BI

N

BI

N

BI

N

BI

N

BI

N

BI

N

BI

N

BI

N

BI

N

BI

N

BI

N

BI

N

SEWING

MACHINE

SEWING

MACHINE

SEWING

MACHINE

KEEP 15' SEPARATION BETWEEN

WORK STATIONS.

MATCH LINE A

M

AT

CH

L

IN

E

B

MATCH LINE A MATCH LINE A

M

AT

CH

L

IN

E

B M

AT

CH

L

IN

E B

FMTV

TRUCK DOCK

RETAINING WALLMHE STORAGE

CHARGING STATIONS

UP

3 RISERS

UP

3 RISERS

UP

UP

UP

UP

UP

KNOX BOX

LOCATION

RETAINING WALL

ICE

MAKER

A-210 A-211

8' X 8'

CASED OPENING

8' X 8' CASED

OPENING

C O

U N

TE

R

T

YP

E B

C O

U N

TE

R

T

YP

E B

C O

U N

TE

R

T

YP

E B

C O

U N

TE

R

T

YP

E

BC

O U

N

TE

R T

YP

E

B C

O U

N

TE

R T

YP

E

B

C O

U N

TE

R

T

YP

E A

C O

U N

TE

R

T

YP

E A

C O

U N

TE

R

T

YP

E A

C O

U N

TE

R

T

YP

E A

C O

U N

TE

R

T

YP

E A

C O

U N

TE

R

T

YP

E A

C O

U N

TE

R

T

YP

E A

C O

U N

TE

R

T

YP

E A

COUNTER TYPE ACOUNTER TYPE ACOUNTER TYPE ACOUNTER TYPE ACOUNTER TYPE A

C O

U N

TE

R

T

YP

E A

C O

U N

TE

R

T

YP

E A

C O

U N

TE

R

T

YP

E A

C O

U N

TE

R

T

YP

E A

C O

U N

TE

R

T

YP

E A

C O

U N

TE

R

T

YP

E A

C O

U N

TE

R

T

YP

E A

C O

U N

TE

R

T

YP

E A

C O

U N

TE

R

T

YP

E A

C O

U N

TE

R

T

YP

E B

C O

U N

TE

R

T

YP

E B

C O

U N

TE

R

T

YP

E A

C O

U N

TE

R

T

YP

E A

C O

U N

TE

R

T

YP

E A

C O

U N

TE

R

T

YP

E A

C O

U N

TE

R

T

YP

E C

A-211

A-211

A-211

A-211

A-211

A-211

A-211

A-211

A-211

A-211 2

A-211

A-211

CONCRETE PADCONCRETE WALK

CONCRETE WALK

211.0'

211.0'

211.0'

211.0'

211.0' 211.0'

211.0'

211.0'

211.0'

211.0'

211.0'

211.0' 211.0'

211.0' 211.0'

211.0'

211.0'

211.0'

211.0'

211.0'

RFID

RFID

RFID

PAINT STRIPING

ON FLOOR

PAINT STRIPING

ON FLOOR PAINT STRIPING

ON FLOOR

NOTE: HOLD BOLLARDS

MIN. 4'-0" FROM EXTERIOR

WALL FACE TO AVOID CONFLICT

WITH PIER FOOTING

PORTAL FRAME W/

X-BRACING ABOVE

BRACED BAY BRACED BAY

BRACED BAY

BR

AC

ED

B

AY

BR

AC

ED

B

AY

BR

AC

ED

B

AY

BR

AC

ED

B

AY

BRACED BAY

PORTAL FRAME W/

X-BRACING ABOVE

TURNDOWN SLAB

STAIR - COORD

W/ ARCH &

CIVIL. SEE

DETAILS

SHEET SB601

STAIR -

COORD. W/

ARCH & CIVIL.

SEE DETAILS

SHEET SB601

RETAINING WALL, SEE

TYP DETAIL ON SHEET

SB505. COORD WITH CIVIL

S

DOCK LEVELER,

SEE SB504

S

MATCHLINE

M

AT

C H

LI

N

E

MATCHLINE

MATCHLINEMATCHLINE

M

AT

C H

LI

N

E

MATCHLINE

MATCHLINEMATCHLINE

M

AT

C H

LI

N

E

MATCHLINE

MATCHLINEMATCHLINE

M

AT

C H

LI

N

E

MATCHLINE

MATCHLINEMATCHLINE

M

AT

C H

LI

N

E

MATCHLINE

MATCHLINE

BRACED BAY

COLUMNS FOR PRE-FABRICATED

CANOPY, SEE ARCH.O

U

TS

ID

E

FL

AN

G E

O F

C O

L.

TOF = -5'-0"

TOF = -7'-0"

TOF = -7'-0"

TOF = -7'-0"

TOF = -7'-0"

OUTSIDE FLANGE OF COL.

OUTSIDE FLANGE OF COL

O U

TS

ID

E

FL

AN

G

E O

F C

O L

TOF = -5'-0"

CIIP DX

WAREHOUSE

WAREHOUSE

MECH 2

TER 2

ELECT 2

RFID

PH 1 ISSUE

TAILORING

PH 2 ISSUE

WAREHOUSE

WAREHOUSE

BREAKROOM

TER.

PH 1 ISSUE

ELECT 1

CIIP DX

CONT

SCAN 1

SCAN 2

OPEN OFFICE

NIGHT ISSUE

CONF

D.

D.

OFF

OFF

OFF

OFF

BRIEFING RM

MEN

JAN

MOTHERS RM

UNISEX TOILET

WOMEN

BREAK ROOM

CIF RETAINED ISSUE

VEST A

VEST B

TER 1

MECH 1

RFID

VEST C

WOMEN

JAN

BREAK

VEST D

AFEES

DRESSING (MEN)

DRESSING (WOMEN)

PH 2 ISSUE

PH 2 ISSUE

MECH 3

STEAM PRESS

TER 3

ELECT 3

TAILORING

STOR

TAILORING

MEN

MOTHER RM

CADRE

OFF

PAY PHONE

DROPS

ATM DATA

DROPS

PAY PHONE

DROPS

WP

WAREHOUSE

THIS COMPOSITE PLAN PRESENTS A OVERALL

LOCATION VIEW OF ALL FLOOR PLAN PARTS. THE

ACTUAL SPECIFIC FLOOR PLANS SHEETS ARE

INDICATED BY THE KEY PLAN BELOW.

COMPOSITE PLAN:

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\k6enxoaa\Documents\FY18JA76149_RECEPTION COMPLEX_MEP_R18_k6enxoaa.rvt

8/16/2019 10:12:11 AM

JU

N

E

W

2H P1

9R

D . V

AU

G

H N

P.

S

U

LL

IV

AN

2-

-0

TN100

TE

LE

C O

M M

U N

IC

AT

IO

N

S

PL

AN

C O

M

PO

SI

TE

H

AG

O

O D

A

VE

N U

E C

H

AR

LE

ST

O N

D

IS

TR

IC

T C

H

AR

LE

ST

O N

, S O

U

TH

C

AR

O

LI

N A

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

SA

VA

N

N

AH

D

IS

TR

IC

T

W

. O G

LE

TH

O R

PE

A

VE

SA

VA

N N

AH

, G

A

FO

R

T

JA

C

KS

O N

, S O

U

TH

C

AR

O

LI

N A

R

EC

EP

TI

O N

C O

M

PL

EX

P

H

AS

E

FY

8, P

N

VO

LU

M E

-C

LO

TH

IN

G

IN

IT

IA

L

IS

SU

E

PO

IN

T

(C

IIP

M . B

R

EN

N

AN

ISSUE FOR CONSTRUCTION

TRUE NORTHPLAN NORTH

KEY PLAN

PART C PART D

PART

A

PART B

PART E

SCALE: 3/64"=1'-0"

1632 32TELECOMMUNICATIONS PLAN COMPOSITE1

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

E D

IN

A C

C O

R D

A N C

E W

IT

H

A M

E N D

M

EN

T

A U

G

TN101 TN102

TN103 TN104

TN105

CIIP DX

TER 2

ELECT 2

PH 1 ISSUE

TN401

RFID

OFFICE

PH 1 ISSUE

WAREHOUSE

SECURE STORAGE

WAREHOUSE

CORRIDOR

T2

T2T2 T2T2

T2 T2

T1

T1

T1 T2

T2

T2

T1

T1 T1

T4

T4

T4

T4

T4

T4 T4 T4

T1

FIRE PUMP

1 1

1. SEE SHEET TN001 FOR LEGEND, AND NOTES.

2. SEE E-001 FOR MOUNTING HEIGHT DETAIL AND ADDITIONAL NOTES.

3. SEE TN501 FOR CABLE TRAY AND GROUNDING DETAILS.

4. SEE TN502 FOR OUTLET DETAILS.

5. PROVIDE THREE 2" CONDUITS FROM THE PAY PHONES AND ATM AREA

TO TER 3. SEE SHEET TN602.

TELECOMMUNICATIONS NOTES:CABLE TRAY SCHEDULE

ITEM WIDTH

1 12" 0" 8' - 6" AFF CABLE RUNWAY (LADDER TYPE) CABLE TRAY

2 12" 4" 10' - 3" AFF WELDED WIRE (BASKET TYPE) CABLE TRAY

3 12" 4" 13' - 6" AFF WELDED WIRE (BASKET TYPE) CABLE TRAY

EDGE

HEIGHT

MOUNTING

HEIGHT

TYPE

SINGLE ANALOG TELECOMMUNICATIONS OUTLET WITH

(1) CATEGORY 6, 8P8C CONNECTOR. MH = 54" AFF UOI.

QUAD OUTLET WITH (2) CATEGORY 6, 8P8C (RJ45 TYPE)

CONNECTORS: (1) VOICE, (1) DATA, AND (2) BLANK

SPACES. MH = 18" AFF UOI.

2D - DENOTES QUAD OUTLET WITH (3) CATEGORY 6,

8P8C (RJ45 TYPE) CONNECTORS: (1) VOICE, (2)

DATA (NIPR AND DLA), AND (1) BLANK SPACE FOR

WORK STATIONS.

WP - DENOTES OUTLET TO BE IN A NEMA 4X,

NON-METALLIC, GRAY, WEATHERPROOF

ENCLOSURE.

T1 - DENOTES TELECOMMUNICATIONS CABLING

TERMINATION LOCATION T1 TERMINATES IN TER 1,

T2 TERMINATES IN TER 2, T3 TERMINATES IN TER 3,

T4 TERMINATES IN TER 4.

QUAD OUTLET WITH (2) CATEGORY 6, 8P8C (RJ45 TYPE)

CONNECTORS: (2) DATA (NIPR AND DLA), AND (2) BLANK

SPACES. MH = 18" AFF UOI.

QUAD FLOOR OUTLET WITH (3) CATEGORY 6, 8P8C

(RJ45 TYPE) CONNECTORS: (1) VOICE, (2) DATA, AND (1)

BLANK SPACE FOR WORK STATIONS. MH = FLUSH WITH

FLOOR. SEE SHEET EP501 FOR DETAIL.

QUAD FLOOR OUTLET WITH (2) CATEGORY 6, 8P8C

(RJ45 TYPE) CONNECTORS: (2) DATA, AND (2) BLANK

SPACES. MH = FLUSH WITH FLOOR. SEE SHEET EP501

FOR DETAIL.

DUPLEX TELECOMMUNICATIONS OUTLET WITH (1)

CATEGORY 6, 8P8C (RJ45 TYPE) CONNECTORS AND (1)

BLANK POSITIONS FOR TV DATA CONNECTION.

MH = 80" AFF UOI.

CEILING MOUNTED DATA TELECOMMUNICATIONS OUTLET

WITH (2) 8-PIN MODULAR JACKS FOR GFGI WIRELESS

ACCESS POINTS. CABLING FOR WAP'S SHALL BE CAT 6A

RATED.

2D

TV

T1

TELECOMMUNICATIONS LEGEND:

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\k6enxoaa\Documents\FY18JA76149_RECEPTION COMPLEX_MEP_R18_k6enxoaa.rvt

8/16/2019 10:12:25 AM

JU

N

E

W

2H P1

9R

D . V

AU

G

H N

P.

S

U

LL

IV

AN

2-

-0

TN101

TE

LE

C O

M M

U N

IC

AT

IO

N

S

PL

AN

PA

R

T A

H

AG

O

O D

A

VE

N U

E C

H

AR

LE

ST

O N

D

IS

TR

IC

T C

H

AR

LE

ST

O N

, S O

U

TH

C

AR

O

LI

N A

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

SA

VA

N

N

AH

D

IS

TR

IC

T

W

. O G

LE

TH

O R

PE

A

VE

SA

VA

N N

AH

, G

A

FO

R

T

JA

C

KS

O N

, S O

U

TH

C

AR

O

LI

N A

R

EC

EP

TI

O N

C O

M

PL

EX

P

H

AS

E

FY

8, P

N

VO

LU

M E

-C

LO

TH

IN

G

IN

IT

IA

L

IS

SU

E

PO

IN

T

(C

IIP

M . B

R

EN

N

AN

ISSUE FOR CONSTRUCTION

TRUE NORTHPLAN NORTH

KEY PLAN

PART C PART D

PART

A

PART B

PART E

SCALE: 3/32"=1'-0"

816 16TELECOMMUNICATIONS PLAN - PART A1

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

E D

IN

A C

C O

R D

A N C

E W

IT

H

A M

E N D

M

EN

T

A U

G

TAILORING

PH 2 ISSUE

WAREHOUSE

WAREHOUSE

BREAKROOM

TER.

TN401

RFID

ELECT.

WAREHOUSE OFFICES

WAREHOUSE

JAN. CL

TOILET

CORRIDOR

CORRIDOR

2 2

MECH.

164 2D

T4 2D T4

T3

T3

T3

T3

T3

T3

T3

T3

T3

T3

T3

T3T3

T3

T3

T3

T3

T3

T3

T3T2

T2T2

T2

T2

T2

T2

T3

T3T2

T2

T2 T2

T4

T4

T4T4

T4

T4

T4

T4

T4

2D T4

2D T4

2D T4

2D T4

T4

T4

T4

T2

OFFICE

CABLE TRAY SCHEDULE

ITEM WIDTH

1 12" 0" 8' - 6" AFF CABLE RUNWAY (LADDER TYPE) CABLE TRAY

MOUNTING

HEIGHT

TYPE

1. SEE SHEET TN001 FOR LEGEND, AND NOTES.

2. SEE E-001 FOR MOUNTING HEIGHT DETAIL AND ADDITIONAL NOTES.

3. SEE TN501 FOR CABLE TRAY AND GROUNDING DETAILS.

4. SEE TN502 FOR OUTLET DETAILS.

5. PROVIDE THREE 2" CONDUITS FROM THE PAY PHONES AND ATM AREA

TO TER 3. SEE SHEET TN602.

TELECOMMUNICATIONS NOTES:

SINGLE ANALOG TELECOMMUNICATIONS OUTLET WITH

(1) CATEGORY 6, 8P8C CONNECTOR. MH = 54" AFF UOI.

QUAD OUTLET WITH (2) CATEGORY 6, 8P8C (RJ45 TYPE)

CONNECTORS: (1) VOICE, (1) DATA, AND (2) BLANK

SPACES. MH = 18" AFF UOI.

2D - DENOTES QUAD OUTLET WITH (3) CATEGORY 6,

8P8C (RJ45 TYPE) CONNECTORS: (1) VOICE, (2)

DATA (NIPR AND DLA), AND (1) BLANK SPACE FOR

WORK STATIONS.

WP - DENOTES OUTLET TO BE IN A NEMA 4X,

NON-METALLIC, GRAY, WEATHERPROOF

ENCLOSURE.

T1 - DENOTES TELECOMMUNICATIONS CABLING

TERMINATION LOCATION T1 TERMINATES IN TER 1,

T2 TERMINATES IN TER 2, T3 TERMINATES IN TER 3,

T4 TERMINATES IN TER 4.

QUAD OUTLET WITH (2) CATEGORY 6, 8P8C (RJ45 TYPE)

CONNECTORS: (2) DATA (NIPR AND DLA), AND (2) BLANK

SPACES. MH = 18" AFF UOI.

QUAD FLOOR OUTLET WITH (3) CATEGORY 6, 8P8C

(RJ45 TYPE) CONNECTORS: (1) VOICE, (2) DATA, AND (1)

BLANK SPACE FOR WORK STATIONS. MH = FLUSH WITH

FLOOR. SEE SHEET EP501 FOR DETAIL.

QUAD FLOOR OUTLET WITH (2) CATEGORY 6, 8P8C

(RJ45 TYPE) CONNECTORS: (2) DATA, AND (2) BLANK

SPACES. MH = FLUSH WITH FLOOR. SEE SHEET EP501

FOR DETAIL.

DUPLEX TELECOMMUNICATIONS OUTLET WITH (1)

CATEGORY 6, 8P8C (RJ45 TYPE) CONNECTORS AND (1)

BLANK POSITIONS FOR TV DATA CONNECTION.

MH = 80" AFF UOI.

CEILING MOUNTED DATA TELECOMMUNICATIONS OUTLET

WITH (2) 8-PIN MODULAR JACKS FOR GFGI WIRELESS

ACCESS POINTS. CABLING FOR WAP'S SHALL BE CAT 6A

RATED.

2D

TV

T1

TELECOMMUNICATIONS LEGEND:

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\k6enxoaa\Documents\FY18JA76149_RECEPTION COMPLEX_MEP_R18_k6enxoaa.rvt

8/16/2019 10:12:39 AM

JU

N

E

W

2H P1

9R

D . V

AU

G

H N

P.

S

U

LL

IV

AN

2-

-0

TN102

TE

LE

C O

M M

U N

IC

AT

IO

N

S

PL

AN

PA

R

T B

H

AG

O

O D

A

VE

N U

E C

H

AR

LE

ST

O N

D

IS

TR

IC

T C

H

AR

LE

ST

O N

, S O

U

TH

C

AR

O

LI

N A

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

SA

VA

N

N

AH

D

IS

TR

IC

T

W

. O G

LE

TH

O R

PE

A

VE

SA

VA

N N

AH

, G

A

FO

R

T

JA

C

KS

O N

, S O

U

TH

C

AR

O

LI

N A

R

EC

EP

TI

O N

C O

M

PL

EX

P

H

AS

E

FY

8, P

N

VO

LU

M E

-C

LO

TH

IN

G

IN

IT

IA

L

IS

SU

E

PO

IN

T

(C

IIP

M . B

R

EN

N

AN

ISSUE FOR CONSTRUCTION

TRUE NORTHPLAN NORTH

KEY PLAN

PART C PART D

PART

A

PART B

PART E

SCALE: 3/32"=1'-0"

816 16TELECOMMUNICATIONS PLAN - PART B1

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

E D

IN

A C

C O

R D

A N C

E W

IT

H

A M

E N D

M

EN

T

A U

G

PH 1 ISSUE

ELECT 1

CIIP DX

CONT

SCAN 1

SCAN 2

OPEN OFFICE

NIGHT ISSUE

CONF

D.

D.

OFF

OFF

OFF

OFF

BRIEFING RM

MEN

MOTHERS RM

UNISEX TOILET

BREAK ROOM

CIF RETAINED ISSUE

VEST A

RFID

TN401

2 2

BRIEFING RM

RFID

CIF RETAINED ISSUE

CLASSROOM

MECH 1

CIIP DX

TER 1

NIGHT ISSUE

CORRIDOR

CORRIDOR

CORRIDOR

OPEN OFFICE

CORRIDOR

CORRIDOR

T2

T2

T2

T2

T2

T2

T2

T2 T2 T2

T2 T2

T2

T2

T2

T2 T2

T2

T2

T2

T2 T2

T2

T2

T2

T2

T2 T2

T2

T2T2 T2 T2

T2

T2

T2

T2

T2

T2

T2 2D

T2 2D

T2

T2

T2 2D

T2 2D

T2T2

T1T1T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1 T1 T1T1

T1 T1

T1

T1 T1 T1 T1 T1

T1 T1 T1 T1 T1

T1 T1 T1 T1 T1

T1

T1

T1 T1

T1

T1

T1

T1

T1

T1

T1

T2T2

T2 T2

T1

T1 T1

T2MOUNT

CATV OUTLET

AT 18" AFF

1. SEE SHEET TN001 FOR LEGEND, AND NOTES.

2. SEE E-001 FOR MOUNTING HEIGHT DETAIL AND ADDITIONAL NOTES.

3. SEE TN501 FOR CABLE TRAY AND GROUNDING DETAILS.

4. SEE TN502 FOR OUTLET DETAILS.

5. PROVIDE THREE 2" CONDUITS FROM THE PAY PHONES AND ATM AREA

TO TER 3. SEE SHEET TN602.

TELECOMMUNICATIONS NOTES:CABLE TRAY SCHEDULE

ITEM WIDTH

1 12" 0" 8' - 6" AFF CABLE RUNWAY (LADDER TYPE) CABLE TRAY

MOUNTING

HEIGHT

TYPE

SINGLE ANALOG TELECOMMUNICATIONS OUTLET WITH

(1) CATEGORY 6, 8P8C CONNECTOR. MH = 54" AFF UOI.

QUAD OUTLET WITH (2) CATEGORY 6, 8P8C (RJ45 TYPE)

CONNECTORS: (1) VOICE, (1) DATA, AND (2) BLANK

SPACES. MH = 18" AFF UOI.

2D - 2D - DENOTES QUAD OUTLET WITH (3) CATEGORY 6,

8P8C (RJ45 TYPE) CONNECTORS: (1) VOICE, (2)

DATA (NIPR AND DLA), AND (1) BLANK SPACE FOR

WORK STATIONS.

WP - DENOTES OUTLET TO BE IN A NEMA 4X,

NON-METALLIC, GRAY, WEATHERPROOF

ENCLOSURE.

T1 - DENOTES TELECOMMUNICATIONS CABLING

TERMINATION LOCATION T1 TERMINATES IN TER 1,

T2 TERMINATES IN TER 2, T3 TERMINATES IN TER 3,

T4 TERMINATES IN TER 4.

QUAD OUTLET WITH (2) CATEGORY 6, 8P8C (RJ45 TYPE)

CONNECTORS: (2) DATA (NIPR AND DLA), AND (2) BLANK

SPACES. MH = 18" AFF UOI.

QUAD FLOOR OUTLET WITH (3) CATEGORY 6, 8P8C

(RJ45 TYPE) CONNECTORS: (1) VOICE, (2) DATA, AND (1)

BLANK SPACE FOR WORK STATIONS. MH = FLUSH WITH

FLOOR. SEE SHEET EP501 FOR DETAIL.

QUAD FLOOR OUTLET WITH (2) CATEGORY 6, 8P8C

(RJ45 TYPE) CONNECTORS: (2) DATA, AND (2) BLANK

SPACES. MH = FLUSH WITH FLOOR. SEE SHEET EP501

FOR DETAIL.

DUPLEX TELECOMMUNICATIONS OUTLET WITH (1)

CATEGORY 6, 8P8C (RJ45 TYPE) CONNECTORS AND (1)

BLANK POSITIONS FOR TV DATA CONNECTION.

MH = 80" AFF UOI.

CEILING MOUNTED DATA TELECOMMUNICATIONS OUTLET

WITH (2) 8-PIN MODULAR JACKS FOR GFGI WIRELESS

ACCESS POINTS. CABLING FOR WAP'S SHALL BE CAT 6A

RATED.

2D

TV

T1

TELECOMMUNICATIONS LEGEND:

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\k6enxoaa\Documents\FY18JA76149_RECEPTION COMPLEX_MEP_R18_k6enxoaa.rvt

8/16/2019 10:12:54 AM

JU

N

E

W

2H P1

9R

D . V

AU

G

H N

P.

S

U

LL

IV

AN

2-

-0

TN103

TE

LE

C O

M M

U N

IC

AT

IO

N

S

PL

AN

PA

R

T C

H

AG

O

O D

A

VE

N U

E C

H

AR

LE

ST

O N

D

IS

TR

IC

T C

H

AR

LE

ST

O N

, S O

U

TH

C

AR

O

LI

N A

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

SA

VA

N

N

AH

D

IS

TR

IC

T

W

. O G

LE

TH

O R

PE

A

VE

SA

VA

N N

AH

, G

A

FO

R

T

JA

C

KS

O N

, S O

U

TH

C

AR

O

LI

N A

R

EC

EP

TI

O N

C O

M

PL

EX

P

H

AS

E

FY

8, P

N

VO

LU

M E

-C

LO

TH

IN

G

IN

IT

IA

L

IS

SU

E

PO

IN

T

(C

IIP

M . B

R

EN

N

AN

ISSUE FOR CONSTRUCTION

TRUE NORTHPLAN NORTH

KEY PLAN

PART C PART D

PART

A

PART B

PART E

SCALE: 3/32"=1'-0"

816 16TELECOMMUNICATIONS PLAN - PART C1

MATCHLINE A MATCHLINE A

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

E D

IN

A C

C O

R D

A N C

E W

IT

H

A M

E N D

M

EN

T

A U

G

CONF

D.

BREAK

VEST D

AFEES

DRESSING (MEN)

DRESSING (WOMEN)

PH 2 ISSUE

MECH 3

STEAM PRESS

TER 3

ELECT 3

TAILORING

TAILORING

MEN

MOTHER RM

CADRE

OFF

TN401

PH 2 ISSUE

STOR

CORRIDOR

CORRIDOR

OPEN OFFICE

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

CATV

BACKBOARD

T3

T3

T3

T3

T3T3

T3

T3

T3

T3

T3

T3

T3

T3

T3

T3

T3

T3

T3

T3

T3

T3T3

T3 T3 2D

T3

T3

T3

T3T3

T3

T3T2

T2

T2

T2

T2 T2

T2 T2

T2

T2

T2

T2 T2

T2

T2

T2

T2

T2

T2

T2T2 T2 T2

T2

T2

T2

T3 2D

T3 2D

T3

T2

T2

T3

T3T3

T2

MOUNT

CATV OUTLET

AT 18" AFF

1 1

CABLE TRAY SCHEDULE

ITEM WIDTH

1 12" 0" 8' - 6" AFF CABLE RUNWAY (LADDER TYPE) CABLE TRAY

MOUNTING

HEIGHT

TYPE

1. SEE SHEET TN001 FOR LEGEND, AND NOTES.

2. SEE E-001 FOR MOUNTING HEIGHT DETAIL AND ADDITIONAL NOTES.

3. SEE TN501 FOR CABLE TRAY AND GROUNDING DETAILS.

4. SEE TN502 FOR OUTLET DETAILS.

5. PROVIDE THREE 2" CONDUITS FROM THE PAY PHONES AND ATM AREA

TO TER 3. SEE SHEET TN602.

TELECOMMUNICATIONS NOTES:

SINGLE ANALOG TELECOMMUNICATIONS OUTLET WITH

(1) CATEGORY 6, 8P8C CONNECTOR. MH = 54" AFF UOI.

QUAD OUTLET WITH (2) CATEGORY 6, 8P8C (RJ45 TYPE)

CONNECTORS: (1) VOICE, (1) DATA, AND (2) BLANK

SPACES. MH = 18" AFF UOI.

2D - DENOTES QUAD OUTLET WITH (3) CATEGORY 6,

8P8C (RJ45 TYPE) CONNECTORS: (1) VOICE, (2)

DATA (NIPR AND DLA), AND (1) BLANK SPACE FOR

WORK STATIONS.

WP - DENOTES OUTLET TO BE IN A NEMA 4X,

NON-METALLIC, GRAY, WEATHERPROOF

ENCLOSURE.

T1 - DENOTES TELECOMMUNICATIONS CABLING

TERMINATION LOCATION T1 TERMINATES IN TER 1,

T2 TERMINATES IN TER 2, T3 TERMINATES IN TER 3,

T4 TERMINATES IN TER 4.

QUAD OUTLET WITH (2) CATEGORY 6, 8P8C (RJ45 TYPE)

CONNECTORS: (2) DATA (NIPR AND DLA), AND (2) BLANK

SPACES. MH = 18" AFF UOI.

QUAD FLOOR OUTLET WITH (3) CATEGORY 6, 8P8C

(RJ45 TYPE) CONNECTORS: (1) VOICE, (2) DATA, AND (1)

BLANK SPACE FOR WORK STATIONS. MH = FLUSH WITH

FLOOR. SEE SHEET EP501 FOR DETAIL.

QUAD FLOOR OUTLET WITH (2) CATEGORY 6, 8P8C

(RJ45 TYPE) CONNECTORS: (2) DATA, AND (2) BLANK

SPACES. MH = FLUSH WITH FLOOR. SEE SHEET EP501

FOR DETAIL.

DUPLEX TELECOMMUNICATIONS OUTLET WITH (1)

CATEGORY 6, 8P8C (RJ45 TYPE) CONNECTORS AND (1)

BLANK POSITIONS FOR TV DATA CONNECTION.

MH = 80" AFF UOI.

CEILING MOUNTED DATA TELECOMMUNICATIONS OUTLET

WITH (2) 8-PIN MODULAR JACKS FOR GFGI WIRELESS

ACCESS POINTS. CABLING FOR WAP'S SHALL BE CAT 6A

RATED.

2D

TV

T1

TELECOMMUNICATIONS LEGEND:

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\k6enxoaa\Documents\FY18JA76149_RECEPTION COMPLEX_MEP_R18_k6enxoaa.rvt

8/16/2019 10:13:08 AM

JU

N

E

W

2H P1

9R

D . V

AU

G

H N

P.

S

U

LL

IV

AN

2-

-0

TN104

TE

LE

C O

M M

U N

IC

AT

IO

N

S

PL

AN

PA

R

T D

H

AG

O

O D

A

VE

N U

E C

H

AR

LE

ST

O N

D

IS

TR

IC

T C

H

AR

LE

ST

O N

, S O

U

TH

C

AR

O

LI

N A

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

SA

VA

N

N

AH

D

IS

TR

IC

T

W

. O G

LE

TH

O R

PE

A

VE

SA

VA

N N

AH

, G

A

FO

R

T

JA

C

KS

O N

, S O

U

TH

C

AR

O

LI

N A

R

EC

EP

TI

O N

C O

M

PL

EX

P

H

AS

E

FY

8, P

N

VO

LU

M E

-C

LO

TH

IN

G

IN

IT

IA

L

IS

SU

E

PO

IN

T

(C

IIP

M . B

R

EN

N

AN

ISSUE FOR CONSTRUCTION

TRUE NORTHPLAN NORTH

KEY PLAN

PART C PART D

PART

A

PART B

PART E

SCALE: 3/32"=1'-0"

816 16TELECOMMUNICATIONS PLAN - PART D1

MATCHLINE A MATCHLINE A

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

E D

IN

A C

C O

R D

A N C

E W

IT

H

A M

E N D

M

EN

T

A U

G

4-PAIR CAT-6 COPPER, 24 AWG

8-PIN

MODULAR

(RJ45) JACK

1" CONDUIT

4" X 2" X 2-1/4" BOX

WITH SINGLE GANG

PLASTER RING AND

TELEPHONE

MOUNTING

PLATE.

MOUNTING LUG

ON WALL

PHONE

ONLY

MOUNTING LUG

ON WALL

PHONE

ONLY

1" CONDUIT

ONE RG11 CABLE TO

CATV BACKBOARD.

TYPE "F"

CONNECTOR

TV

4" X 2" X 2-1/4" BOX

WITH SINGLE GANG

PLASTER RING.

8-PIN

MODULAR

(RJ45) JACK

CAT-6 COPPER CABLE

24 AWG, BLUE JACKET

(DATA)

CAT-6 COPPER CABLE

24 AWG, GREY JACKET (VOICE)

CAT-6 COPPER CABLE

24 AWG, BLUE JACKET (DATA)

1" CONDUIT TO

CABLE TRAY ABOVE

CEILING. PROVIDE

BUSHING ON END OF

CONDUIT.

8-PIN MODULAR (RJ45) JACKS

BLUE FOR DATA

GREY FOR VOICE

BLANK COVERS (TYPICAL)

LABEL HOLDER

4-11/16" X 4-11/16" X 2-1/4"

BOX WITH DOUBLE GANG

PLASTER RING.

T E L E P H O N E

WEATHERPROOF

PHONE ENCLOSURE

WITH CAT-6 WALL

OUTLET INSIDE.

WP

NOMINAL 14"H x 10"W x

10"D; NON-METALLIC OR

CAST ALUMINUM WITH

DOOR GASKET AND NON-

LOCKING DOOR LATCH.

TYPICAL COMMUNICATION OUTLETS

NOT TO SCALE

VOICE

8-PIN RJ-45

(TYPICAL)

MOUNTING PINS FOR

PHONE (TYPICAL)

F-CONNECTOR

(TYPICAL)

CATV

TV

TV

DATA

DATA

8-PIN RJ-45

(TYPICAL)

UNUSED PORTS

SHALL HAVE

BLANK COVERS.

VOICE

DATA

NIPR

8-PIN RJ-45

(TYPICAL)

UNUSED PORTS

SHALL HAVE

BLANK COVERS.

VOICE

DATA

DLA

2D

8-PIN RJ-45

(TYPICAL)

1 NIPR NETWORK OUTLET

1 DLA NETWORK OUTLET

DATA

DATA

NIPR

DATA

DLA

8-PIN RJ-45

(TYPICAL)

DATA

8-PIN RJ-45

(TYPICAL)

1 SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\k6enxoaa\Documents\FY18JA76149_RECEPTION COMPLEX_MEP_R18_k6enxoaa.rvt

8/16/2019 10:13:20 AM

JU

N

E

W

2H P1

9R

D . V

AU

G

H N

P.

S

U

LL

IV

AN FY

PN

7H Q

_E T5

.D

G N

2-

-0

TN502

TE

LE

C O

M M

U N

IC

AT

IO

N

S D

ET

AI

LS

H

AG

O

O D

A

VE

N U

E C

H

AR

LE

ST

O N

D

IS

TR

IC

T C

H

AR

LE

ST

O N

, S O

U

TH

C

AR

O

LI

N A

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

SA

VA

N

N

AH

D

IS

TR

IC

T

W

. O G

LE

TH

O R

PE

A

VE

SA

VA

N N

AH

, G

A

FO

R

T

JA

C

KS

O N

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .