Drawings_Volume_2_-_IFC_Reception_Phase_I.pdf
PDF 35 MB Posted
- Attached to
- Reception Complex Phase 1 Federal contract opportunity
- Solicitation number
- W912HP19R2000
About this file
This document contains drawings and specifications for a federal construction solicitation seeking offers for the Reception Complex Phase 1 project at Fort Jackson. The solicitation was posted as W912HP19R2000 with attachments including proposal forms, past performance questionnaires, and five volumes of drawings and specifications. A site visit is scheduled for August 20, 2019 at 11:00am at Fort Jackson, with questions due via Projnet and offers due September 6, 2019 at 2:00pm Eastern. The project involves construction of a reception complex to process and house new military recruits at the Army base.
Drawings Vol 2
View the file
Other files for this federal contract opportunity
Show all 44
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
G
F
E
D
C
B
A
1 I 2
SHEET ID.
G-001 COVER SHEET
GI001 INDEX OF DRAWINGS
GI002 INDEX OF DRAWINGS
GI003 GENERAL NOTES, ABBREVIATIONS
S-001 GENERAL STRUCTURAL NOTES
S-002 GENERAL STRUCTURAL NOTES
SB101 FOUNDATION PLAN - COMPOSITE
SB102 FOUNDATION PLAN - PART A
SB103 FOUNDATION PLAN - PART B
SB104 FOUNDATION PLAN - PART C
SB105 FOUNDATION PLAN - PART D
SB106 FOUNDATION PLAN - PART E
SB501 FOUNDATION DETAILS
SB502 FOUNDATION DETAILS
SB503 FOUNDATION DETAILS
SB504 FOUNDATION DETAILS
SB505 FOUNDATION DETAILS
SB601 FOUNDATION SCHEDULES
SB602 PIER SCHEDULE AND DETAILS
SF101 SLAB PLAN - COMPOSITE
SF102 SLAB PLAN - PART A
SF103 SLAB PLAN - PART B
SF104 SLAB PLAN - PART C
SF105 SLAB PLAN - PART D
SF106 SLAB PLAN - PART E
SF107 ROOF FRAMING PLAN - COMPOSITE
SF301 FRAMING SECTIONS
SF302 FRAMING SECTIONS
SF303 FRAMING SECTIONS
SF304 FRAMING SECTIONS
SF305 WALL SECTIONS
SF501 FRAMING DETAILS
SF502 FRAMING DETAILS
A-100A LIFE SAFETY ANALYSIS
A-100B LIFE SAFETY PLAN
A-101 FLOOR PLAN - COMPOSITE
A-102 FLOOR PLAN - PART A
A-103 FLOOR PLAN - PART B
A-104 FLOOR PLAN - PART C
A-105 FLOOR PLAN - PART D
A-106 FLOOR PLAN - PART E
A-107 ROOF PLAN
A-108 REFLECTED CEILING PLAN A
A-109 REFLECTED CEILING PLAN B
A-110 REFLECTED CEILING PLAN C
A-111 REFLECTED CEILING PLAN D
A-112 REFLECTED CEILING PLAN E
A-201 NORTH AND SOUTH ELEVATIONS
A-202 EAST AND WEST ELEVATIONS
A-203 ENLARGED NORTH EXTERIOR ELEVATIONS
A-204 ENLARGED SOUTH EXTERIOR ELEVATIONS
A-205 ENLARGED EAST ELEVATIONS
A-206 ENLARGED WEST ELEVATIONS
A-207 INTERIOR ELEVATIONS
A-208 INTERIOR ELEVATIONS
A-209 INTERIOR ELEVATIONS
A-210 INTERIOR ELEVATIONS
A-211 INTERIOR ELEVATIONS
A-301 BUILDING CROSS SECTION
A-302 BUILDING LONGITUDINAL SECTION
A-303 ENLARGED BUILDING SECTIONS (m ADMIN.
A-304 ENLARGED BUILDING SECTIONS
A-305 ENLARGED BUILDING SECTIONS
A-310 WALL SECTIONS
A-321 WALL DETAILS II
A-330 COLUMN DETAILS
A-331 COLUMN DETAILS
A-400 ENLARGED CORE PLANS
A-401 ENLARGED UNIT PLANS
A-404 INTERIOR DETAILS
A-405 INTERIOR DETAILS
A-406 INTERIOR DETAILS
A-510 ROOF DETAILS
A-511 ROOF DETAILS
A-513 ROOF DETAILS
A-514 EXTERIOR DETAILS
A-520 CEILING DETAILS
A-601 PARTITION TYPES
A-602 PARTITION TYPES
A-603 DOOR SCHEDULE AND DETAILS
A-604 DOOR DETAILS
A-605 DOOR DETAILS
A-606 WINDOW TYPES
A-607 LOUVER DETAILS
A-608 FINISH SCHEDULE
A-700 AIR BARRIER PLAN
A-701 AIR BARRIER PLAN
A-801 PERSPECTIVE VIEWS
1-101 FURNITURE PLAN - COMPOSITE
1-102 FURNITURE PLAN - PART A
1-103 FURNITURE PLAN - PART B
1-104 FURNITURE PLAN - PART C
1-105 FURNITURE PLAN - PART D
1-501 SIGNAGE TYPICAL$ & DETAILS
1-601 ROOM SCHEDULE & FINISH LEGEND
1-611 ROOM SCHEDULE & FINISH LEGEND
1-621 SIGNAGE SCHEDULE
_r nr·:ams ...... .,..,u�ung1v� v"'lx.agn
20-JUN-2019 12:21
k6enxjlh
I
TITLE
3 I 4 I 5 I 6 I
INDEX OF DRAWINGS
SHEET ID. TITLE
FA001 FIRE ALARM LEGEND AND OPERATIONS MATRIX
FA100 FIRE ALARM AND MNS PLAN - COMPOSITE
FA101 FIRE ALARM AND MNS PLAN - PART A
FA102 FIRE ALARM AND MNS PLAN - PART B
FA103 FIRE ALARM AND MNS PLAN - PART C
FA104 FIRE ALARM AND MNS PLAN - PART D
FA105 FIRE ALARM AND MNS PLAN - PART E
FA501 FIRE ALARM & MASS NOTIFICATION DETAILS
FA601 FIRE ALARM, MASS NOTIFICATION AND PAGING SYSTEM DIAGRAM AND NOTES
FX001 FIRE PROTECTION LEGEND AND GENERAL NOTES
FX101 FIRE PROTECTION PLAN - COMPOSITE
FX102 FIRE PROTECTION PLAN - PART A
FX103 FIRE PROTECTION PLAN - PART B
FX104 FIRE PROTECTION PLAN - PART C
FX105 FIRE PROTECTION PLAN - PART D
FX106 FIRE PROTECTION PLAN - PART E
FX501 FIRE PROTECTION DETAILS I
FX502 FIRE PROTECTION DETAILS II
FX503 FIRE PROTECTION DETAILS Ill
FX901 FIRE PUMP ROOM ISOMETRIC VIEW I
FX902 FIRE PUMP ROOM ISOMETRIC VIEW II
P-001 PLUMBING LEGEND
PL 101 PLUMBING PLAN - DOMESTIC - COMPOSITE
PL102 PLUMBING PLAN - DOMESTIC - PART A
PL103 PLUMBING PLAN - DOMESTIC - PART B
PL104 PLUMBING PLAN - DOMESTIC - PART C
PL105 PLUMBING PLAN - DOMESTIC - PART D
PL 111 PLUMBING PLAN - SANITARY - COMPOSITE
PL 112 PLUMBING PLAN - SANITARY - PART A
PL113 PLUMBING PLAN - SANITARY - PART B
PL 114 PLUMBING PLAN - SANITARY - PART C
PL115 PLUMBING PLAN - SANITARY - PART D
PL401 PLUMBING ENLARGED PLANS
PL402 PLUMBING ENLARGED PLANS
PL501 PLUMBING DETAILS
PL502 PLUMBING DETAILS
PL503 PLUMBING DETAILS
PL504 PLUMBING DETAILS
PL505 PLUMBING DETAILS
PL506 PLUMBING DETAILS
PL601 PLUMBING SCHEDULES
PL602 PLUMBING SCHEDULES
PL701 PLUMBING RISER DIAGRAM
PL702 PLUMBING RISER DIAGRAM
PL703 PLUMBING RISER DIAGRAM
PL704 PLUMBING RISER DIAGRAM
PL705 PLUMBING RISER DIAGRAM
PL711 PLUMBING RISER DIAGRAM
PL712 PLUMBING RISER DIAGRAM
PL713 PLUMBING RISER DIAGRAM
PL714 PLUMBING RISER DIAGRAM
PL715 PLUMBING RISER DIAGRAM
M-001 HVAC LEGEND
MH101 HVAC PLAN - COMPOSITE
MH102 HVAC PLAN - PART A
MH103 HVAC PLAN - PART B
MH104 HVAC PLAN - PART C
MH105 HVAC PLAN - PART D
MH111 HVAC THERMOSTAT AND SENSOR PLAN - PART A
MH112 HVAC THERMOSTAT AND SENSOR PLAN - PART B
MH113 HVAC THERMOSTAT AND SENSOR PLAN - PART C
MH114 HVAC THERMOSTAT AND SENSOR PLAN - PART D
MH301 HVAC SECTIONS I
MH302 HVAC SECTIONS II
MH303 HVAC SECTIONS Ill
MH304 HVAC SECTIONS IV
MH305 HVAC SECTIONS V
MH306 HVAC SECTIONS VI
MH401 HVAC ENLARGED PLANS I
MH402 HVAC ENLARGED PLANS II
MH403 HVAC ENLARGED PLANS Ill
MH404 HVAC ENLARGED PLANS IV
MH405 HVAC ENLARGED PLANS V
MH501 HVAC DETAILS I
MH502 HVAC DETAILS II
MH503 HVAC DETAILS Ill
MH504 HVAC DETAILS IV
MH505 HVAC DETAILS V
MH506 HVAC DETAILS VI
MH507 HVAC DETAILS VII
MH601 HVAC SCHEDULES I
MH602 HVAC SCHEDULES II
MH603 HVAC SCHEDULES Ill
MH701 HYDRONIC CHILLED WATER PIPING SCHEMATIC
MH702 HYDRONIC HOT WATER PIPING SCHEMATIC
MI001 HVAC CONTROLS LEGEND
MI002 HVAC CONTROL GENERAL NOTES
MI003 HVAC SCHEDULING INSTRUCTIONS
Ml801 AHU-1 CONTROL SCHEMATIC
Ml802 AHU-1 CONTROL SEQUENCE OF OPERATION
Ml803 AHU-1 CONTROL SEQUENCE OF OPERATION (CONT.l AND SCHEDULES
Ml804 AHU-1 CONTROL POINTS SCHEDULE
Ml805 AHU-2 CONTROL SCHEMATIC
Ml806 AHU-2 CONTROL SEQUENCE OF OPERATION
Ml807 AHU-2 CONTROL SCHEDULES
Ml808 AHU-2 CONTROL POINTS SCHEDULE
Ml809 AHU-3 CONTROL SCHEMATIC
7 I 8 I 9 I
SHEET ID. TITLE
Ml810 AHU-3 CONTROL SEQUENCE OF OPERATION
Ml811 AHU-3 CONTROL SCHEDULES
Ml812 AHU-3 CONTROL POINTS SCHEDULE
Ml813 AHU-4 CONTROL SCHEMATIC
Ml814 AHU-4 CONTROL SEQUENCE OF OPERATION
Ml815 AHU-4 CONTROL SCHEDULES
Ml816 AHU-4 CONTROL POINTS SCHEDULE
Ml817 ERV CONTROL SCHEMATIC & SCHEDULE
Ml818 ERV CONTROL SEQUENCE OF OPERATION
Ml819 ERV CONTROL POINTS SCHEDULE
Ml820 HVU CONTROLS
Ml821 MISCELLANEOUS CONTROL SCHEMATICS
Ml822 MISCELLANEOUS CONTROL SCHEMATICS
Ml824 MISCELLANEOUS CONTROL POINTS SCHEDULES
Ml825 MISCELLANEOUS CONTROL POINTS SCHEDULES
Ml826 MISCELLANEOUS CONTROL POINTS SCHEDULES
Ml827 MISCELLANEOUS CONTROL POINTS SCHEDULES
Ml828 MISCELLANEOUS CONTROL POINTS SCHEDULES
Ml829 HEATING HOT WATER CONTROL SCHEMATIC
Ml830 HEATING HOT WATER CONTROL SEQUENCE OF OPERATION
Ml831 HEATING HOT WATER CONTROL POINTS SCHEDULE
Ml832 CHILLED WATER CONTROL SCHEMATIC
Ml833 CHILLED WATER CONTROL SEQUENCE OF OPERATION
Ml834 CHILLED WATER CONTROL POINTS SCHEDULE
Ml836 DOMESTIC WATER CONTROLS
MP101 HVAC HYDRONIC PIPING PLAN
MP102 HVAC HYDRONIC PIPING PLAN - PART A
MP103 HVAC HYDRONIC PIPING PLAN - PART B
MP104 HVAC HYDRONIC PIPING PLAN - PART C
MP105 HVAC HYDRONIC PIPING PLAN - PART D
E-001 LEGEND AND NOTES
EG101 LIGHTNING PROTECTION PLAN - COMPOSITE
EG501 LIGHTING PROTECTION DETAILS
EG502 LIGHTNING PROTECTION DETAILS
EG503 MISC GROUNDING DETAILS
EL 100 LIGHTING PLAN - COMPOSITE
EL 101 LIGHTING PLAN - PART A
EL 102 LIGHTING PLAN - PART B
EL103 LIGHTING PLAN - PART C
EL 104 LIGHTING PLAN - PART D
EL105 LIGHTING PLAN - PART E
EL501 LUMINAIRE SCHEDULE AND DETAILS
EL502 LUMINAIRE DETAILS
EL503 LUMINAIRE DETAILS
EL601 LIGHTING CONTROL STRATEGY SCHEDULE
EL602 LIGHTING CONTROL DETAILS
EL603 LIGHTING CONTROL DIAGRAMS
EL604 LIGHTING CONTROL DIAGRAMS
EP100 POWER PLAN - COMPOSITE
EP101 POWER PLAN - PART A
EP102 POWER PLAN - PART B
EP103 POWER PLAN - PART C
EP104 POWER PLAN - PART D
EP105 POWER PLAN - PART E
EP106 POWER PLAN - ROOF
EP401 POWER- ENLARGED PLANS I
EP402 POWER- ENLARGED PLANS II
EP403 POWER - ENLARGED PLANS Ill
EP404 POWER - ENLARGED PLANS IV
EP501 ELECTRICAL DETAILS
EP601 POWER ONE-LINE DIAGRAM
EP602 MOTOR AND EQUIPMENT FEEDER SCHEDULE
EP603 PANEL FEEDER SCHEDULE
EP604 TRANSFORMER FEEDER SCHEDULE
EP610 PANEL SCHEDULES
EP611 PANEL SCHEDULES
EP612 PANEL SCHEDULES
EP613 PANEL SCHEDULES
EP614 PANEL SCHEDULES
EP615 PANEL SCHEDULES
EP616 PANEL SCHEDULES
EP617 PANEL SCHEDULES
EP618 PANEL SCHEDULES
EP619 PANEL SCHEDULES
EP620 PANEL SCHEDULES
EY001 SPECIAL SYSTEMS LEGEND AND NOTES
EY100 SPECIAL SYSTEMS PLAN - COMPOSITE
EY101 SPECIAL SYSTEMS PLAN - PART A
EY102 SPECIAL SYSTEMS PLAN - PART B
EY103 SPECIAL SYSTEMS PLAN - PART C
EY104 SPECIAL SYSTEMS PLAN - PART D
EY105 SPECIAL SYSTEMS PLAN - PART E
EY401 SPECIAL SYSTEMS - ENLARGED PLANS
EY501 SPECIAL SYSTEMS DETAILS - ACCESS CONTROL
EY502 SPECIAL SYSTEMS DETAILS - SECURITY CAMERAS
EY503 SPECIAL SYSTEM DETAILS - EQUIPMENT RACKS
EY601 SPECIAL SYSTEMS ACCESS CONTROL SYSTEM INFRASTRUCTURE ONE-LINE DIAGRAM
EY602 SPECIAL SYSTEMS CCTV INFRASTRUCTURE ONE-LINE DIAGRAM
EY603 SPECIAL SYSTEMS AV SYSTEMS ONE-LINE DIAGRAM - CLASSROOM
EY604 SPECIAL SYSTEMS AV SYSTEMS ONE LINE DIAGRAM - BRIEFING ROOM
TN001 TELECOMMUNICATIONS LEGEND AND GENERAL NOTES
TN100 TELECOMMUNICATIONS PLAN - COMPOSITE
TN101 TELECOMMUNICATIONS PLAN - PART A
TN102 TELECOMMUNICATIONS PLAN - PART B
TN103 TELECOMMUNICATIONS PLAN - PART C
TN104 TELECOMMUNICATIONS PLAN - PART D
TN105 TELECOMMUNICATIONS PLAN - PART E
m US Army Corps of Engineers®
UJ
z ii::uCJ)UJ 0
0:: <( :a
0 0
UJ0Zo 0 0 zo
Q1,'! z u i
�� f- <J) 0:: ... <( � oo f- D.. Oo UJ "' -::c (!) ' :::, UJ �N UJ 1'l CJ) z ..J � z f- ' g� 8 <( N CJ) :::, ' u ;j:
. . >< UJ ·-
:a � <( N z8
UJ ·-.. z ..J g>- <( "' u::: -=';;: "' z 0 "' 0 0:: � UJ UJ �:::; z 0:: z UJ UJ
I
�-u f- - ..J 0
- <( UJ u :a :::, UJ ci:i ffl I "' CJ) I :a �z:::, . 0 --; 0 u --; CJ) D.. CJ) <(
CJ)0:: ww z f- N
- u w ..... (!) - :::, -a;Z 0:: ZN w�wu LL -> cn 0 □ <( cnz□z o.. 0 O 00:: f- 0 f-ow C!> cn
>- I!: I 0::
::. <( <J)
0:: I co I en
<( z z- i5:::;w D..
ocn w0:: <( <( I :::, (.) D.. CJ) "' CJ) I t;) <t -f- - ...J ...J co<( :::J a.. r,.. -O ;:. zt:: cn _oo..� ZU co(!)
Oz'l"""z cn o>--
�-LI.I
(.) f- f- <( D.. 0 .., w ...J f- (.) (.)
0:: w ' oo:: N LI. w
...J
CJ)0:: w ww z1-->T"""-u<(o (!) _w" z a::: a.. ;;:; w f- 0:: <( IL�O (!) 0 Cl ::c CJ) I f- ID..<(W<( a::::z ....J z oz C!l z (.) <( 0 <( >-�:;:� ::!: (/) 0 (/)0:: 0 <( -
CJ)
z u..
X z
SHEET ID
GI001
ISSUE FOR CONSTRUCTION
A N
S I
D
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
F
IL
E N
A M
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
®of Engineers
US Army Corps k6enxjlh
20-JUN-2019 12:26
IP_PWP:dms22498\jungi001v2ix.dgn
C A
T E
G O
R Y C
O D
E
-2
-0 ju n g i0 v ix .d g n
IN
D
E X O
F D
R A
W
IN
G S
F O
R T J
A C
K S
O N S
O U
T H C
A R
O L
IN
A
R E
C E
P T
IO
N C
O M
P L E
X P
H A
S E
F Y P
N
U S A
R M
Y C
O R
P S O
F E
N G
IN
E E
R S
J
M C
T
IE
R N
A N
J
H A
IR
E
P S
U L L
IV
A N
J U
N E
ISSUE FOR CONSTRUCTION
S A
V A
N N
A H D
IS
T R
IC
T
W
O G
L E
T H
O R
P E A
V E
S A
V A
N N
A H
G A
W
H P
R
V O
L U
M E C
L O
T H
IN
G I
N
IT
IA
L I S
S U
E P
O
IN
T
C
II
P
GI002
SHEET ID.
INDEX OF DRAWINGS
D E
S C
R
IP
T
IO
N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
SHEET ID.
TITLESHEET ID.
TITLETITLE
C H
A R
L E
S T
O N D
IS
T R
IC
T
H
A G
O O
D A
V E
N U
E
C H
A R
L E
S T
O N S
C
TN401 TELECOMMUNICATIONS ENLARGED PLANS
TN501 TELECOMMUNICATIONS DETAILS
TN502 TELECOMMUNICATIONS DETAILS
TN601 TELECOMMUNICATIONS DIAGRAMS
TN602 TELECOMMUNICATIONS AND CATV RISER DIAGRAMS
S-101X LAWN EQUIPMENT BUILDING (LEB)
S-501X LAWN EQUIPMENT BUILDING DETAILS
E-001X ELECTRICAL LEGEND & GENERAL NOTES
EG101X LIGHTNING PROTECTION PLAN
EG501X LIGHTNING PROTECTION SYSTEM DETAILS
EL101X LIGHTING PLAN
EL501X LUMINAIRE SCHEDULE AND CONTROL DETAILS
EP101X POWER PLAN
EP601X POWER RISER DIAGRAM & PANEL SCHEDULE
ET601X TELECOMM DIAGRAM & DETAILS
SHEET LOGICMATERIALS
EARTH
DRAWING ABBREVIATIONS GENERAL NOTES
C (cont) ---------------------
COMM COMMUNICATION
CONC CONCRETE
CONC FLR CONCRETE FLOOR
CONF CONFERENCE
CONT CONTINUE, CONTINUOUS
COORD COORDINATE
CORR CORRIDOR
CP CONCRETE PIPE
CPT CARPET
CR CONTROL ROOM
CS CAST STONE
CSWK CASEWORK
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CTF CERAMIC TILE FLOOR
CTR CENTER
CU FT CUBIC FEET
CW CASEMENT WINDOW
D ---------------------
D DEPTH
D LABEL CLASS D DOOR
DBL DOUBLE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIR DIRECTION
DIST DISTANCE
DOC DOCUMENT
DR DOOR
DS DOWNSPOUT
E ---------------------
E LABEL CLASS E DOOR
EA EACH
EF EACH FACE
EIFS EXTERIOR INSULATION
AND FINISH SYSTEM
EJ EXPANSION JOINT
ES EACH SIDE
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
ENTR ENTRANCE
EPS EXPANDED POLYSTYRENE
EQ EQUAL
EWC ELECTRIC WATER COOLER
EXP EXPOSED, EXPANSION
EXT EXTERIOR, EXTINGUISHER
EXT GR EXTERIOR GRADE
F ---------------------
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR
PANEL
FAS BD FASCIA BOARD
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER
CABINET
FED FEDERAL
FF FINISH FLOOR
FFE FINISH FLOOR ELEVATION
FF INSUL FOIL BACKED INSULATION
FGL FIBERGLASS
FH FIRE HOSE
FHP FULL HEIGHT PARTITION
FIN FINISH
FIN BS FINISH BOTH SIDES
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FIXT FIXTURE
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLMT FLUSH MOUNT
FLR FLOOR
FM FACTORY MUTUAL
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FR FIRE RESISTANT
FRG FIBER REINFORCED GYPSUM
FRMG FRAMING
FRP FIBERGLASS REINFORCED
PLASTIC
FRTW FIRE RETARDANT TREATED
WOOD
FS FEDERAL SPECIFICATION
FSTNR FASTENER
FT FEET
FTG FOOTING
FWC FABRIC WALLCOVERING
G ---------------------
G NATURAL GAS
GALV GALVANIZED
GB GRAB BAR
GEJ GUTTER EXPANSION JOINT
GFCI GOVERNMENT FURNISHED
CONTRACTOR INSTALLED
GFGI GOVERNMENT FURNISHED
GOVERNMENT INSTALLED
GFRG GLASS-FIBER-
REINFORCED GYPSUM
GLZ GLAZING
GR FL GROUND FLOOR
GUT GUTTER
GWB GYPSUM WALL BOARD
GYP BD GYPSUM BOARD
GYP PLAS GYPSUM PLASTER
H -------------
HB HOSE BIBB
HC HANDICAPPED
HDPE HIGH DENSITY
POLYETHYLENE
HDW HARDWARE
HDWD HARDWOOD
HEPA HIGH EFFICIENCY
PARTICULATE AIR (FILTER)
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HORIZ HORIZONTAL
HR HOUR
HT HEIGHT
HYDR HYDRAULIC
I ---------------------
IBC INTERNATIONAL BUILDING
CODE
INSUL INSULATION
INT INTERIOR
ILO IN LIEU OF
J ---------------------
JAN JANITOR
JT JOINT
K ---------------------
KPD KEYPAD
KIT KITCHEN
KPL KICKPLATE
L ---------------------
LAM LAMINATE
LAV LAVATORY
LBR LUMBER
LBS POUND
LDG LANDING
LF LINEAR FEET (FOOT)
LG LIGHT GAUGE
LIB LIBRARY
LIN LINEAR
LKR LOCKER
LOC LOCATION
LT LIGHT
LVDR LOUVER DOOR
LVR LOUVER
M ---------------------
MACH RM MACHINE ROOM
MATL MATERIAL
MAX MAXIMUM
MC MOISTURE CONTENT
MD METAL DECK
MECH MECHANICAL
MECH RM MECHANICAL ROOM
MEMB MEMBRANE
MF MILL FINISH
MFR MANUFACTURER
MID MIDDLE
MIN MINIMUM, MINUTE
MIRR MIRROR
MISC MISCELLANEOUS
MLDG MOLDING (MOULDING)
MO MASONRY OPENING
MOD MODIFY
MB MOISTURE BARRIER
MTD MOUNTED
MTG MOUNTING
MTL METAL
MVBL MOVABLE
MWP MEMBRANE WATERPROOFING
N ---------------------
N NORTH
NA NOT APPLICABLE
N (cont) ---------------------
NFPA NATIONAL FIRE
PROTECTION ASSOCIATION
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NP NO PAINT
NRC NOISE REDUCTION
COEFFICIENT
NTS NOT TO SCALE
O -------------------
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OFD OVERFLOW DRAIN
OFF OFFICE
OGL OBSCURE GLASS
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPQ OPAQUE
OWSJ OPEN WEB STEEL JOIST
OPR OPERABLE
ORD OVERFLOW ROOF DRAIN
ORIG ORIGINAL
P --------------------
PA PUBLIC ADDRESS
PAR PARAPET
PAT PATTERN
PB PULL BOX
PBD PARTICLEBOARD
PCC PRECAST CONCRETE
PCF POUNDS PER CUBIC FOOT
PCT PERCENT
PERF PERFORATED
PERIM PERIMETER
PH PHASE
PIL PILASTER
PL PROPERTY LINE
PL GL PLATE GLASS
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLBG PLUMBING
PLG PILING
PLYWD PLYWOOD
PNL PANEL
PP PL PUSH/PULL PLATE
PR PAIR
PRCST PRECAST
PREFIN PREFINISHED
PRKG PARKING
PS CONC PRESTRESSED CONCRETE
PSF POUNDS PER SQUARE
FOOT
PSI POUNDS PER SQUARE
INCH
PT PRESSURE TREATED
PTD PAPER TOWEL DISPENSER
PTDR PAPER TOWEL DISPENSER
AND RECEPTACLE
PTN PARTITION
PWR POWER
Q --------------------
QT QUARRY TILE
QTY QUANTITY
R --------------------
RB RESILIENT BASE
RBM REINFORCED BRICK
MASONRY
RBR RUBBER
RC REINFORCED CONCRETE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RDG INS RIGID INSULATION, SOLID
REC RECESSED
REF REFERENCE
REM REMOVABLE
REP REPAIR
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
RESIL RESILIENT
REST RESTROOM
RF RESILIENT FLOORING
RFG ROOFING
RH ROOF HATCH
RHR RIGHT HAND REVERSE
RL ROOF LEADER
RLG RAILING
RM ROOM
RO ROUGH OPENING
RSD ROLLING STEEL DOOR
R (cont) --------------------
RV ROOF VENT
RVL REVEAL
S --------------------
SB SPLASH BLOCK
SCHED SCHEDULE
SD SMOKE DETECTOR
SF SQUARE FOOT (FEET)
SFTWD SOFTWOOD
SGL SINGLE
SHT MTL SHEET METAL
FLASH (FLASHING)
SHTHG SHEATHING
SHV SHELVING
SIM SIMILAR
SJ SCORED JOINT
SKLT SKYLIGHT
SLNT SEALANT
SMK SMOKE
SMLS SEAMLESS
SP EL SPOT ELEVATION
SPEC SPECIFICATION
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SS STAINLESS STEEL
SSMR STANDING SEAM METAL ROOF
ST STAIRS
STC SOUND TRANSMISSION
COEFFICIENT
STD STANDARD
STL STEEL
STL JST STEEL JOIST
STL RF DK STEEL ROOF DECK
STOR STORAGE
STR STRINGERS
STRB/HRN STROBE/HORN
STRUC STRUCTURAL
SUB FL SUBFLOOR
SUSP SUSPENDED
SV SHEET VINYL
SW SIDEWALK
T --------------------
T TREAD
T/S TUB/SHOWER
TD TRENCH DRAIN
TEL TELEPHONE
TEMP TEMPORARY
TER TERRAZZO
TFF TOP OF FINISH FLOOR
TH THICK
THK THICKNESS
TK BD TACKBOARD
TMPD GL TEMPERED GLASS
TN TRUE NORTH
TOF TOP OF FOOTING
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOPO TOPOGRAPHY
TOS TOP OF SLAB
TRANS TRANSOM
TRTD TREATED
TV TELEVISION
TYP TYPICAL
U --------------------
UG UNDERGROUND
UH UNIT HEATER
UL UNDERWRITER
LABORATORIES
UNO UNLESS NOTED OTHERWISE
UPS UNINTERRUPTIBLE POWER
SYSTEM
V --------------------
VAV VARIABLE AIR VOLUME/UNIT
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VTR VENT THRU ROOF
W --------------------
W/ WITH
WC WATER CLOSET
WD WOOD
WDW WINDOW
W/O WITHOUT
WWF WELDED WIRE FABRIC
X --------------------
XFMR TRANSFORMER
A ---------------------
A LABEL CLASS A DOOR
A/C AIR CONDITION
A/C UNIT AIR CONDITIONING UNIT
A/E ARCHITECT/ENGINEER
AB ANCHOR BOLT
ABV ABOVE
ACC ACCESSIBLE
ACS AUTOMATIC CONTROL
SYSTEM
ACS DR ACCESS DOOR
ACS PNL ACCESS PANEL
ACT ACOUSTICAL CEILING TILE
ADA AMERICANS WITH
DISABILITIES ACT
ADJ ADJACENT
ADMIN ADMINISTRATION
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AGGR AGGREGATE
AHU AIR HANDLING UNIT
AIB AIR INFILTRATION BARRIER
ALT ALTERNATE
ALUM ALUMINUM
ANOD ANODIZE
APPROX APPROXIMATE
AR AS REQUIRED
ARCH ARCHITECT
ASC ABOVE SUSPENDED
CEILING
ASSY ASSEMBLY
ATC ACOUSTICAL TILE CEILING
AVG AVERAGE
AWT ACOUSTICAL WALL
TREATMENT
B ---------------------
B LABEL CLASS B DOOR
BALC BALCONY
BD BOARD
BDRY BOUNDARY
BEJ BRICK EXPANSION JOINT
BFF BELOW FINISH FLOOR
BHMA BUILDER'S HARDWARE
MANUFACTURER'S
ASSOCIATION
BLDG BUILDING
BLKG BLOCKING
BLT IN BUILT-IN
BN BULLNOSE
BOS BOTTOM OF STEEL
BOT BOTTOM
BRG BEARING
BRKT BRACKET
BSMTBASEMENT
BTWN BETWEEN
BUR BUILT-UP ROOFING
C ---------------------
C LABEL CLASS C DOOR
CAB CABINET
CATW CATWALK
CAV CAVITY
CBB CEMENTITIOUS (BACKER)
BOARD
CD CONSTRUCTION
DOCUMENTS
CDW CHILLED DRINKING WATER
CEM PLAS CEMENT PLASTER
CER CERAMIC
CF CONTRACTOR FURNISHED
CFCI CONTRACTOR
FURNISHED/CONTRACTOR
INSTALLED
CFE CONTRACTOR FURNISHED
EQUIPMENT
CFM CUBIC FEET PER MINUTE
CFMF COLD-FORMED METAL
FRAMING
CFS CUBIC FEET PER SECOND
CG CORNER GUARD
CI CAST IRON
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLG DIFF CEILING DIFFUSER
CLG HT CEILING HEIGHT
CLL COLUMN LINE
CLO CLOSET
CLR COLOR
CMU CONCRETE MASONRY UNIT
CNDS CONDENSATE
CDR CARD READER
CO CLEANOUT
COL COLUMN
0 GRID/COLUM
N LINE
DESIGNATOR
INTERIOR ELEVATION
SECTION
ROOM
NAME/NUMBER
REVISION
TAG
PLAN, BLOW-UP
DETAIL
PLAN NORTH
NORTH ARROW
w/ TRUE NORTH
INDICATION
(DASHED)
Name Elevation REFERENCE LEVEL
PLATE NUMBER WHERE
SECTION/DETAIL IS
DRAWN
PLATE NUMBER WHERE
SECTION/DETAIL IS
DRAWN
PLATE NUMBER WHERE
SECTION/DETAIL IS
DRAWN
A-101
SIM
EXTERIOR ELEVATION
PLATE NUMBER WHERE
SECTION/DETAIL IS
DRAWN
A-101
SYMBOLS
INTERIOR ELEVATION SYMBOL
EXTERIOR ELEVATION SYMBOL
SECTION SYMBOL
CALLOUT SYMBOL
LEVEL SYMBOL
GENERAL SYMBOLS
Room name
CENTERLINE
INDICATOR
1/2 1 21
SCALE: 1"=1'-0"
SCALE BAR
VIEW NAME1
VIEW TITLE BAR
SAND
CONCRETE/ PRECAST
CONCRETE
STONE
BRICK
CMU
PLYWOOD
RIGID INSULATION
BATT INSULATION
GYPSUM BOARD,
PLASTER
EIFS
1. THESE LEGENDS ARE COMPOSED OF STANDARD SYMBOLS AND ARE PERTINENT TO THE CONDITIONS
ON THIS SET OF DRAWINGS TO THE EXTENT APPLICABLE.
2. ADDITIONAL LEGENDS AND/OR ABBREVIATIONS MAY APPEAR IN THIS SET OF DRAWINGS TO INDICATE
SPECIFIC CONDITIONS IN LIEU OF SYMBOLS SHOWN ON THIS SHEET.
A-101
SIM
A101
Ref
R ef
Ref
R ef
AE201
DISCIPLINE*:
G - GENERAL
C - CIVIL
L - LANDSCAPE
S - STRUCTURAL
A - ARCHITECTURE
DISCIPLINE DESIGNATOR
SHEET TYPE
DESIGNATOR
SHEET SEQUENCE
NUMBER
F- FIRE PROTECTION
P - PLUMBING
M - MECHANICAL
E - ELECTRICAL
T-
TELECOMMUNICATIONS
*ADDITIONAL DISCIPLINES MAY BE USED
IN THIS DRAWING SET.
DRAWING NAMING CONVENTION
SHEET ID
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\k6enxjlh\Documents\FY18JA76149_RECEPTION COMPLEX_PROJ_R18_k6enxjlh.rvt 18-Jun-19 2:00:53 PM
JU
N
E
W
2H P1
9R
J.
H
AI
R
E
P.
S
U
LL
IV
AN
2-
-0
GI003
G
EN
ER
AL
N O
TE
S, A
BB
R
EV
IA
TI
O N
S
C H
AR
LE
ST
O
N D
IS
TR
IC
T
H
AG
O
O D
A
VE
N U
E C
H
AR
LE
ST
O N
, S C
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
FO
R
T
JA
C
KS
O N
, S O
U
TH
C
AR
O
LI
N A
R
EC
EP
TI
O N
C O
M
PL
EX
P
H
AS
E
FY
8, P
N
VO
LU
M E
-C
LO
TH
IN
G
IN
IT
IA
L
IS
SU
E
PO
IN
T
(C
IIP
J.
M
C
TI
ER
N
AN
ISSUE FOR CONSTRUCTION
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
GENERAL NOTES:
G-1. THIS STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER ALL BUILDING CONSTRUCTION IS COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES AND SEQUENCES TO ENSURE SAFETY OF THE BUILDING AND ITS COMPONENTS DURING
ERECTION. THIS INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING, TEMPORARY
BRACING, GUYS, OR TIE-DOWNS.
G-2. THE CONTRACT DOCUMENTS DO NOT INDICATE THE MEANS AND METHODS OF CONSTRUCTION. THE
CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK DURING ERECTION AND CONSTRUCTION
AND SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, PROCEDURES,
TECHNIQUES, SEQUENCES, AND SAFETY.
G-3. USE STRUCTURAL DRAWINGS IN CONJUNCTION WITH ALL OTHER DRAWINGS AND SPECIFICATIONS.
COORDINATE THE WORK OF OTHER TRADES INCLUDING, BUT NOT LIMITED TO, THE REQUIREMENTS
FOR SLEEVES, INSERTS, HOLES, HANGERS, AND ANCHORS.
G-4. REPORT DISCREPANCIES IN DIMENSIONS BETWEEN DIFFERENT DRAWINGS TO THE CONTRACTING
OFFICER PRIOR TO BEGINNING WORK IN IMPACTED AREAS.
G-5. DETAILS TITLED OR NOTED AS "TYPICAL" APPLY NOT ONLY WHERE SPECIFICALLY INDICATED OR
REFERENCED, BUT ALSO IN ALL OTHER CASES WHERE THE NATURE OF THE CONSTRUCTION
REQUIRES THEIR USE. DETERMINE APPLICABILITY OF TYPICAL DETAILS FROM DESCRIPTIVE TITLES OR FROM THE SIMILARITY OF A CONSTRUCTION CONDITION TO ANOTHER CONDITION WHERE THE DETAIL
IS SPECIFICALLY INDICATED OR REFERENCED.
G-6. ELEVATIONS ON THE STRUCTURAL DRAWINGS ARE DENOTED AS [±X'-X"] REFERENCED TO THE FINISHED FIRST FLOOR ELEVATION DATUM [0'-0"]. SEE CIVIL DRAWINGS FOR ACTUAL DATUM
ELEVATION.
G-7. REPRODUCTION OF CONTRACT DRAWINGS SHALL NOT BE USED AS SHOP DRAWINGS UNDER ANY
CIRCUMSTANCE.
FOUNDATION AND SLAB NOTES:
F-1. FOUNDATIONS FOR THIS PROJECT HAVE BEEN DESIGNED IN ACCORDANCE WITH THE
RECOMMENDATIONS IN THE GEOTECHNICAL REPORT PREPARED BY THE SAVANNAH DISTRICT TITLED
"SUBSURFACE EXPLORATION AND GEOTECHNICAL ENGINEERING REPORT, RECEPTIONCOMPLEX
PHASE I, FY 18, PN 76149, FT JACKSON, SC", DATED SEPTEMBER 2018.
F-2. FOUNDATIONS HAVE BEEN DESIGNED TO BEAR ON SOIL CAPABLE OF SUPPORTING AN ALLOWABLE BEARING PRESSURE OF 3000 PSF AS STATED IN THE GEOTECHNICAL REPORT REFERENCED ABOVE.
F-3. THE CONTRACTOR SHALL HIRE AN INDEPENDENT TESTING LABORATORY AND GEOTECHNICAL ENGINEER, REGISTERED AND LICENSED IN THE STATE WHERETHE WORK WILL BE ACCOMPLISHED, TO VERIFY THAT ALL OF THE REQUIREMENTS CONTAINED IN SPECIFICATION 31 00 00, EARTHWORK, HAVE
BEEN FOLLOWED AND ACCOMPLISHED.
F-4. ALL EXCAVATIONS SHALL BE PERFORMED SO THAT THE SITE AND THE AREA IMMEDIATELY SURROUNDING THE SITE WHICH AFFECTS CONSTRUCTION OPERATIONS WILL BE CONTINUALLY AND
EFFECTIVELY DRAINED. THE CONTRACTOR SHALL PROVIDE DRAINAGE AND DEWATERING AS
REQUIRED TO ENSURE THAT ALL FOOTING EXCAVATIONS ARE ACCOMPLISHED WITH THE SUBGRADE SOILS REMAINING DRY AND FIRM UNTIL AFTER FOOTINGS ARE PLACED AND BACKFILLED. REMOVAL OF
SURFACE WATER, GROUNDWATER, AND ANY PERCHED WATER CONDITIONS WHICH MIGHT BE
ENCOUNTERED DURING EXCAVATIONS, SHALL BE ACCOMPLISHED BY APPROVED MEANS. REFER TO SPECIFICATION SECTION 31 00 00, EARTHWORK, AND TO SHEET B-301 FOR ADDITIONAL EXCAVATION
REQUIREMENTS.
F-5. DO NOT PLACE FOUNDATION CONCRETE ON FROZEN OR SATURATED SUBGRADES.
F-6. ENSURE THAT EARTH-FORMED FOOTINGS CONFORM TO THE SHAPE, LINES, AND THICKNESSES INDICATED ON THE FOUNDATION PLAN, SECTIONS, AND FOOTING SCHEDULES. EXCAVATION WIDTHS
SHALL BE A MINIMUM OF 4" GREATER THAN DIMENSIONS INDICATED.
F-7. DO NOT INSTALL FOUNDATIONS UNTIL FOUNDATION WORK HAS BEEN COORDINATED WITH ADJACENT
UNDERGROUND UTILITIES.
F-8. PLACE 10 MIL VAPOR RETARDER ON A 4" COMPACTED CAPILLARY WATER BARRIER UNDER ALL INTERIOR SLABS-ON-GRADE (TYPICAL). DO NOT USE VAPOR RETARDER UNDER WAREHOUSE SLAB.
F-9. DRAINAGE AND DEWATERING: ALL EXCAVATION SHALL BE PREFORMED SO THAT THE SITE AND THE AREA IMMEDIATELY SURROUNDING THE SITE WHICH AFFECTS CONSTRUCTION OPERATIONS WILL BE
CONTINUALLY AND EFFECTIVELY DRAINED. THE CONTRACTOR SHALL PROVIDE DRAINAGE AND
DEWATERING AS REQUIRED TO ENSURE THAT ALL FOOTING EXCAVATIONS ARE ACCOMPLISHED WITH
THE SUBGRADE SOILS REMAINING DRY AND FIRM UNTIL AFTER FOOTINGS ARE PLACED AND
BACKFILLED. REMOVAL OF SURFACE WATER, GROUNDWATER, AND ANY PERCHED-WATER
CONDITIONS, WHICH MIGHT BE ENCOUNTERED DURING EXCAVATIONS SHALL BE ACCOMPLISHED BY APPROVED MEANS. REFER TO SPECIFICATION 31 00 00 EARTHWORK FOR ADDITIONAL REQUIREMENTS.
CONCRETE CONSTRUCTION NOTES:
C-1. ALL CONCRETE CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE PROVISIONS OF THE "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE" (ACI 318-14) AND THE SPECIFICATIONS FOR
STRUCTURAL CONCRETE (ACI 301-16) OF THE AMERICAN CONCRETE INSTITUTE (ACI).
C-2. ALL CAST-IN-PLACE CONCRETE SHALL ATTAIN MINIMUM 28-DAY COMPRESSIVE STRENGTH (f'c) OF 4000 PSI AND UTILIZE MAXIMUM WATER-CEMENTITIOUS MATERIAL RATIO (w/cm) OF 0.45. ALL CONCRETE EXPOSED TO WEATHER SHALL BE AIR ENTRAINED. SEE SPECIFICATIONS FOR AIR ENTRAINMENT
REQUIREMENTS.
C-3. CONCRETE DENSITY SHALL BE NORMAL WEIGHT WITH A DENSITY OF 140 PCF TO 150 PCF UNLESS
NOTED OTHERWISE ON PLANS.
C-4. CONCRETE REINFORCING STEEL SHALL BE DEFORMED BARS CONFORMING TO ASTM A615/A615M, GRADE 60 AND SHALL HAVE FABRICATION TOLERANCES IN ACCORDANCE WITH ACI 315. SHOP
FABRICATE REINFORCING BARS WHICH ARE INDICATED TO BE BENT OR HOOKED.
C-5. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185 OR ASTM A497. PROVIDE SHEET-TYPE WELDED
WIRE FABRIC. SHEET LAPS SHALL BE TIED AND LAPPED ONE FULL MESH SPACING PLUS 2".
C-6. CONCRETE REINFORCING STEEL SHALL BE CONTINUOUS UNLESS OTHERWISE INDICATED.
CONTINUOUS REINFORCING STEEL SHALL BE SPLICED AS SHOWN IN SCHEDULE ON S-001UNO ON PLANS. REINFORCING STEEL SHALL BE PLACED SO THAT SPACING IS GREATER THAN OR EQUAL TO 2X
BAR DIAMETER.
C-7. MINIMUM CONCRETE COVER FOR REINFORCING STEEL SHALL BE AS INDICATED. IN NO CASE SHALL
REINFORCEMENT COVER BE LESS THAN THE REQUIREMENTS OF ACI 301.
A. CONCRETE DEPOSITED AGAINST THE GROUND 3"
B. CONCRETE EXPOSED TO EARTH OR WEATHER 2"
C. SLABS AND WALLS (NOT EXPOSED TO EARTH OR WEATHER) 1"
C-8. CONCRETE REINFORCING STEEL MARKED STANDARD HOOK SHALL HAVE A 90° HOOK A MINIMUM OF 12 BAR DIAMETERS IN LENGTH, UNLESS OTHERWISE NOTED. STIRRUPS, TIES, AND 180° HOOKS SHALL
CONFORM TO THE REQUIREMENTS OF ACI 318.
C-9. PROVIDE 1/2" THICK PRE-MOLDED JOINT FILLER MATERIAL WHERE SOG ABUT VERTICAL SURFACES.
C-10. ALL EMBEDDED ITEMS SHALL BE PROPERLY PLACED, ACCURATELY POSITIONED AND MAINTAINED
SECURELY IN PLACE PRIOR TO AND DURING CONCRETE PLACEMENT.
C-11. REINFORCING STEEL SHALL BE SPREAD AT SLEEVES, ANCHORS, RECESSES AND OTHER EMBEDDED
ITEMS UNLESS OTHERWISE INDICATED. REINFORCEMENT SHALL NOT BE CUT TO FACILITATE
PLACEMENT OF EMBEDDED ITEMS, UNLESS INDICATED.
C-12. NO CONCRETE SHALL BE PLACED UNTIL THE OWNER OR THE CONTRACTING OFFICER'S DESIGNATED
REPRESENTATIVE HAS INSPECTED ALL EMBEDDED WORK, INCLUDING REINFORCEMENT.
C-13. ALL EXPOSED CONCRETE EDGES SHALL BE CHAMFERED 3/4" OR AS INDICATED.
C-14. ALUMINUM SHALL NOT BE PLACED IN DIRECT CONTACT WITH CONCRETE UNLESS EFFECTIVELY
COATED OR COVERED TO PREVENT ALUMINUM-CONCRETE REACTION AND ELECTROLYTIC ACTION
BETWEEN ALUMINUM AND STEEL.
C-15. CONCRETE SLAB ON GRADE JOINTS INDICATED ARE DIAGRAMMATIC AND DO NOT REPRESENT ALL OF THE JOINTS REQUIRED FOR SLAB-ON-GRADE CONSTRUCTION. SLAB PANELS BETWEEN JOINTS SHALL BE SQUARE OR NEARLY SO AND SHALL NOT EXCEED AN ASPECT RATIO WITH PANEL LENGTH GREATER THAN 1.5 TIMES THE PANEL WIDTH. MAXIMUM JOINT SPACING SHALL BE 15 FT UNLESS NOTED
OTHERWISE.
C-16. CONTRACTOR SHALL PROVIDE JOINTS AT ALL RE-ENTRANT CORNERS INCLUDING, BUT NOT LIMITED TO, COLUMNS AND SLAB RECESSES.
C-17. IN ADDITION, CONTRACTOR SHALL COORDINATE SLAB ON GRADE JOINT REQUIREMENTS WITH SLAB-
ON-GRADE CONSTRUCTION SEQUENCING. CONTRACTOR SHALL SHOW JOINT LAYOUT ON
REINFORCING SHOP DRAWING SUBMITTAL FOR APPROVAL.
DESIGN CODE NOTES:
D-1. STRUCTURAL DESIGN IS IN ACCORDANCE WITH THE FOLLOWING CODES AND SPECIFICATIONS:
A. IBC 2015, INTERNATIONAL BUILDING CODE
B. ASCE 7-10, MINIMUM DESIGN LOADS FOR BUILDINGS AND STRUCTURES
C. ACI 318-14, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE
D. AISC 360-10, SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS
E. AISI S100-12, NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD
FORMED STEEL STRUCTURAL MEMBERS
F. SDI, STEEL DECK INSTITUTE: DESIGN MANUAL FOR COMPOSITE DECK,
FORM DECK, & ROOF DECK
G. UFC 1-200-01, GENERAL BUILDING REQUIREMENTS, (1 FEB 2018)
H. UFC 3-301-01, STRUCTURAL ENGINEERING, (12 SEP 2016)
I. UFC 3-310-04, SEISMIC DESIGN OF BUILDINGS, (20 JUN 2016)
J. UFC 4-010-01, DOD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS,
(1 OCT 2013)
DESIGN LOAD CRITERIA:
D-2. FIRST FLOOR LIVE LOADS:
WAREHOUSE, SLAB ON GRADE 300 PSF
UNO, SLAB ON GRADE 150 PSF
PLATFORMS 100 PSF
*SLAB DESIGNED FOR 6 KIP FORKLIFT
D-3. ROOF LIVE LOAD: 20 PSF (REDUCIBLE)
*DESIGN RIGID FRAME IN WAREHOUSE PORTION FOR 2 KIP VERTICAL LIVE LOAD
LOCATED ANYWHERE ALONG THE RAFTER
D-4. SNOW LOADS:
RISK CATEGORY II
SNOW IMPORTANCE FACTOR, Is 1.0 MINIMUM GROUND SNOW LOAD, Pg 10 PSF SNOW EXPOSURE FACTOR, Ce 0.9 SNOW THERMAL FACTOR, Ct 1.0 ROOF SLOPE FACTOR, Cs 1.0
FROST PENETRATION DEPTH 0 IN
BALANCED SNOW LOADING:
MINIMUM LOW SLOPE ROOF SNOW LOAD, Pm 10 PSF
UNBALANCED SNOW LOADING:
SEE S-002
SNOW DRIFT LOADING: (HIGH ROOF/LOW ROOF AND CANOPY)
SEE S-002
D-5. WIND LOADS:
RISK CATEGORY II
WIND IMPORTANCE FACTOR, Iw 1.0
BASIC WIND SPEED, V 120 MPH
WIND EXPOSURE CATEGORY C
GUST EFFECT FACTOR, G 0.85
INTERNAL PRESSURE COEFFICIENTS, GCpi +/- 0.18
D-6. SEISMIC LOADS:
RISK CATEGORY II
SEISMIC IMPORTANCE FACTOR, Ie 1.0 MAPPED SPECTRAL RESPONSE ACCELERATION, Ss 0.42
MAPPED SPECTRAL RESPONSE ACCELERATION, S1 0.15
SITE CLASS D
DESIGN SPECTRAL RESPONSE ACCELERATION, Sds 0.41 DESIGN SPECTRAL RESPONSE ACCELERATION, Sd1 0.22
SEISMIC DESIGN CATEGORY D
SEISMIC ANALYSIS PROCEDURE BY MBM
SEISMIC-FORCE RESISTING SYSTEM BY MBM
RESPONSE MODIFICATION FACTOR, R BY MBM
SYSTEM OVERSTRENGTH FACTOR BY MBM
DEFLECTION AMPLIFICATION FACTOR, Cd BY MBM SEISMIC RESPONSE COEFFICIENT, Cs BY MBM
SEISMIC DESIGN BASE SHEAR, V BY MBM
D-7. ANTI-TERRORISM/FORCE PROTECTION CRITERIA:
NEW BUILDING LOCATION PARKING AND ROADWAYS WITHIN
A CONTROLLED PERIMETER
BUILDING CATEGORY PRIMARY GATHERING BUILDING
DESIGN LEVEL OF PROTECTION (LOP) LOW (LLOP)
CONVENTIONAL CONSTR STANDOFF DISTANCE 82 FT
APPLICABLE EXPLOSIVE WEIGHT CLASS II
STEEL DOORS AND FRAMES SPEC 08 11 13
ALUMINUM DOORS AND FRAMES SPEC 08 11 16
ALUMINUM WINDOWS SPEC 08 51 13
GLAZING SPEC 08 81 00
PROGRESSIVE COLLAPSE CRITERIA APPLIES N/A (<3 STORIES)
METAL BUILDING:
MB-1. THE METAL BUILDING SYSTEM HAS BEEN PLANNED TO CONSIST OF A RIGID FRAME STRUCTURE RESISTING GRAVITY AND LATERAL LOADS IN THE PLAN EAST-WEST DIRECTION AND X-BRACING RESISTING LATERAL LOADS IN THE LOW ROOF PLAN NORTH-SOUTH DIRECTION AND PORTAL FRAMES WITH X- BRACING ABOVE RESISTING LATERAL LOADS IN THE HIGH ROOF PLAN NORTH-SOUTH DIRECTION. THE LATERAL FORCE RESISTING SYSTEM AND ALL LATERAL BRACING SHALL BE DESIGNED BY THE METAL BUILDING MANUFACTURER (MBM). DESIGN BUILDING SYSTEM(S) IN ACCORDANCE WITH LATEST EDITIONS
OF IBC, ASCE, AISC, UFC, AND THE MBMA METAL BUILDING SYSTEMS MANUAL.
MB-2. DESIGN BUILDING SYSTEM FOR LIVE LOADS INDICATED AND A COLLATERAL DEAD LOAD OF 10 PSF IN ADDITION TO BUILDING DEAD LOADS (BUILDING DEAD LOADS INCLUDE WEIGHT OF THE ROOF SYSTEM), WIND LOADS AND SEISMIC LOADS. PARAMETERS FOR DEVELOPMENT OF WIND AND SEISMIC LOADS ARE LISTED IN THE GENERAL NOTES. INCLUDE THE EFFECTS OF WINDWARD AND LEEWARD WIND PRESSURE AND SUCTION LOADS. DESIGN RIGID FRAME(S) IN WAREHOUSE PORTION FOR 2 KIP VERTICAL LIVE LOAD
LOCATED ANYWHERE ALONG THE RAFTER.
MB-3. LOAD COMBINATIONS SHALL BE IN ACCORDANCE WITH LATEST EDITION OF IBC UNLESS THE MBMA METAL
BUILDING SYSTEMS MANUAL (LATEST EDITION) LOAD COMBINATIONS ARE MORE STRINGENT.
MB-4. LIMIT THE STORY DRIFT OF THE STRUCTURE IN BOTH DIRECTIONS TO H/480 WITH WIND LOADS BASED ON
SERVICIBILITY WIND SPEEDS OF A 10 YEAR MEAN RECURRENCE INTERVAL .
MB-5. ROOF DIAGONAL BRACING SHALL BE PROVIDED TO TRANSFER DIAPHRAGM FORCES TO THE MBM FRAMES.
MB-6. REDUNDANCY SHALL BE PROVIDED TO THE VERTICAL AND HORIZONTAL BRACING SYSTEMS BY USING
MULTIPLE BAYS OF LATERAL MEMBERS.
MB-7. PIERS AND FOUNDATIONS SHOWN FOR THE BUILDING ARE FOR PRICING ESTIMATES ONLY. THE CONTRACTOR SHALL HIRE A PROFESSIONAL ENGINEER TO DESIGN THE METAL BUILDING FOUNDATIONS FOR ACTUAL BUILDING LOADS PROVIDED BY THE METAL BUILDING MANUFACTURER. THE DESIGN SHALL BE BASED ON THE SOIL PARAMETERS SPECIFIED IN NOTE F-1 ON THIS SHEET AND THE FINAL COLUMN REACTIONS REPORTED BY THE MBM MANUFACTURER. THE FINAL FOUNDATION DESIGN SHALL BE SIGNED AND SEALED BY A PROFESSIONAL ENGINEER AND SHALL BE SUBMITTED TO THE CONTRACTING OFFICER
FOR APPROVAL. FOUNDATIONS FOR ELEMENTS OTHER THAN MBM COLUMN FOUNDATIONS WILL BE
CONSTRUCTED AS SHOWN. SEE PLAN FOR LOCATIONS.
MB-8. THE CONTRACTOR SHALL COORDINATE THE COLUMN ANCHOR BOLT LAYOUT WITH THE MBM
MANUFACTURER. AT LEAST FOUR (4) ANCHOR BOLTS ARE REQUIRED FOR COLUMN BASE PLATES UNO.
ANCHOR BOLTS SHALL NOT BE LESS THAN 3/4" NOMINAL SIZE. ANCHOR BOLTS SHALL BE DESIGNED BY THE MBM SUPPLIER. COLUMN ANCHOR BOLTS SHALL BE POSITIVELY LOCATED USING 1/8" SHEET METAL TEMPLATES FOR ALL COLUMN BASE PLATES. BASE PLATE TEMPLATE ANCHOR BOLT HOLES SHALL NOT EXCEED BOLT DIA. +/- 1/6”. PROVISION SHALL BE MADE FOR ALL ANCHOR BOLTS TO BE RIGIDLY HELD IN POSITION TO PREVENT MOVEMENT DURING CONCRETE PLACEMENT. ANCHOR BOLTS SHALL NOT BE
TIGHTENED PRIOR TO 14 DAYS FOLLOWING CONCRETE PLACEMENT.
MB-9. THE CONTRACTOR SHALL DESIGN, PROVIDE, AND COORDINATE STRUCTURAL FRAMING MEMBERS FOR THE SUPPORT OF ALL HVAC UNITS, DUCTS, FANS, PIPING, ELECTRICAL COMPONENTS, OPERABLE PARTITIONS, ETC. COORDINATE WEIGHT AND ROUTING OF FIRE PROTECTION PIPING AND ADD EXTRA
MEMBERS AS REQUIRED.
MB-10. THE MBM IS RESPONSIBILE FOR PROVIDING ADDITIONAL STRUCTURAL MEMBERS AND CONNECTIONS TO BUILDING SUB-FRAMING AS NECESSARY AROUND WINDOW AND SKYLIGHT OPENINGS SUCH THAT FRAME
ATTACHMENTS MEET ANTITERRORISM/FORCE PROTECTION CRITERIA PER UFC 4-010-01.
DOOR/WINDOW/SKYLIGHT CONNECTIONS TO SUPPORT STRUCTURE AND SUPPORTING FRAMING MEMBERS SHALL BE DESIGNED IN ACCORDANCE WITH ATFP CRITERIA APPLIED UNIFORMLY TO DOOR, WINDOW, AND
SKYLIGHT AREAS.
MB-11. BOTTOM OF COLUMNS SHALL BE DESIGNED AND DETAILED AS A PINNED CONNECTION. COLUMNS SHALL
NOT TRANSFER ANY MOMENT TO CONCRETE.
STEEL CONSTRUCTION NOTES:
S-1. FABRICATION AND ERECTION OF STRUCTURAL STEEL AND DESIGN OF CONNECTIONS SHALL BE IN ACCORDANCE WITH AISC 360-10, "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS" DATED JUNE 22, 2010 AND AISC 303-10, "CODE OF STANDARD PRACTICE FOR BUILDING AND BRIDGES" DATED APRIL 14, 2010.
S-2. UNLESS OTHERWISE NOTED, STRUCTURAL STEEL SHALL BE IN ACCORDANCE WITH THE ABOVE-LISTED
AISC SPECIFICATION AND THE FOLLOWING:
A. WIDE FLANGE SHAPES (50 KSI) ASTM A992
B. HSS HOLLOW SHAPES (46 KSI) ASTM A500, GRADE B
B. PLATES AND ANGLES ASTM A36
C. HIGH STRENGTH BOLTS ASTM A325
D. ANCHOR RODS W/ NUT AND WASHER ASTM F1554, GRADE 36
S-3. ALL SHOP AND FIELD WELDING SHALL BE BY CERTIFIED WELDERS AND SHALL CONFORM TO AWS
STANDARDS. USE E70XX ELECTRODES UNLESS OTHERWISE NOTED. MINIMUM WELD SIZE FOR
STRUCTURAL STEEL IS 3/16" FILLET, UNLESS OTHERWISE NOTED ON PLANS. CURRENT AWS
CERTIFICATIONS SHALL BE AVAILABLE AT THE JOB SITE FOR REVIEW BY THE OWNERS' REPRESENTATIVE.
S-4. ALL BOLTED CONNECTIONS, UNLESS OTHERWISE NOTED, SHALL USE 3/4" DIAMETER HIGH STRENGTH BOLTS WITH HARDENED CARBON STEEL WASHERS AS REQUIRED FOR THE CONNECTION LOADS. IF LOADS ARE NOT INDICATED ON THE DRAWINGS, STEEL FABRICATOR SHALL SIZE CONNECTIONS FOR A MINIMUM OF ONE HALF OF THE UNIFORM LOAD CAPACITY OF THE BEAM AS INDICATED IN THE AISC MANUAL.
S-5. FIELD CUTTING OF STRUCTURAL STEEL MEMBERS BY ANY TRADE SHALL NOT BE PERMITTED. BOLT HOLES
SHALL NOT BE CUT OR ENLARGED BY FLAME CUTTING IN THE FIELD.
S-6. ALL FIELD-BOLTED SHEAR CONNECTIONS SHALL BE SNUG TIGHT BEARING-TYPE CONNECTIONS, THREADS INCLUDED IN THE SHEAR PLANE. BOLTED CONNECTIONS FOR METAL BUILDING PER METAL BUILDING
MANUFACTURER AND SPEC 13 34 19.
S-7. THE CONTRACTOR SHALL SUBMIT FOR APPROVAL DRAWINGS AND DESIGN CALCULATIONS FOR ANY ALTERNATE DETAILS AND MEMBER SPLICES. DRAWINGS AND CALCULATIONS SHALL BE SEALED BY AN
ENGINEER LICENSED IN THE STATE OF THE PROJECT.
S-8. SHOP OR FIELD SPLICES OF STRUCTURAL STEEL MEMBERS ARE PROHIBITED EXCEPT AS DETAILED ON THE DRAWINGS, PERMITTED IN THE SPECIFICATIONS, AS INDICATED ON APPROVED SUBMITTALS, AND AS
SPECIFICALLY APPROVED ON SHOP DRAWINGS PRIOR TO FABRICATION.
S-9. PAINT ALL STEEL BELOW GRADE WITH BITUMINOUS COATING.
S-10. ALL STEEL EXPOSED TO WEATHER SHALL BE HOT-DIPPED GALVANIZED IN ACCORDANCE WITH ASTM A123 FOR MEMBERS AND ASTM A153 FOR CONNECTION ELEMENTS, EXCEPT THAT ARCHITECTURALLY EXPOSED STRUCTURAL STEEL SHALL BE BLAST CLEANED AND COATED IN ACCORDANCE WITH THE STRUCTURAL STEEL AND PAINT SPECIFICATIONS. COORDINATE ALL STEEL FINISHES WITH ARCHITECTURAL DRAWINGS
AND SPECIFICATIONS.
STRUCTURAL LEGEND
SLOPE DIRECTION
INDICATES ELEVATION
REFERENCED
TO FINISHED FLOOR
KEYED PLAN NOTE
COLUMN REFERENCE LINE
(CENTER LINE OF COLUMN)
SPOT ELEVATION
DN
X
[+/- X’-X”]
X
[+/- X’-X”]
SLAB DEPRESSION
BRICK WALL
CONCRETE ELEMENT
COMPACTED EARTH FILL
GROUT
CONCRETE MASONRY UNIT
(CMU)
POROUS FILL
WELDED WIRE FABRIC (WWF)
STRUCTURAL ABBREVIATIONS
SYMBOL DESCRIPTION
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLING UNIT
APPROX APPROXIMATELY
ARCH ARCHITECTURAL
BOC BOTTOM OF CONCRETE
BOF BOTTOM OF FOOTING
BOM BOTTOM OF MASONRY
BOS BOTTOM OF STEEL
BOT BOTTOM
BRG BEARING
CJ CONSTRUCTION JOINT
CL CENTER LINE
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONN CONNECTION
CONC CONCRETE
CONT CONTINUOUS
CONSTR CONSTRUCTION
DCJ DOWELED CONSTRUCTION JOINT
DEG DEGREE
DIA DIAMETER
DN DOWN
DWG(S) DRAWING(S)
EA EACH
EF EACH FACE
EJ EXPANSION JOINT
EL ELEVATION
EOF EDGE OF FOUNDATION
EQ EQUAL
ERV ENERGY RECOVERY VENTILATOR
EW EACH WAY
FF FINISHED FLOOR
FDN FOUNDATION
FTG FOOTING
GA GAUGE
GALV GALVANIZED
GFGI GOVT
HORIZ HORIZONTAL
KIP (k) 1000 POUNDS
SYMBOL DESCRIPTION
LG LONG
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
MAX MAXIMUM
MBM METAL BUILDING MANUFACTURER
MECH MECHANICAL
MEP MECHANICAL, ELECTRICAL, PLUMBING
MFR MANUFACTURER
MIN MINIMUM
NTS NOT TO SCALE
OC ON CENTER
OPP OPPOSITE
PJF PREMOLDED JOINT FILLER
PL PLATE
PLF POUNDS PER LINEAR FOOT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
REINF REINFORCEMENT
REQD REQUIRED
SCHED SCHEDULE
SE SLAB EDGE
SJ SAWED CONTRACTION JOINT
SJI STEEL JOIST INSTITUTE
SIM SIMILAR
SL SLOPE(D)
SOG SLAB ON GRADE
STD STANDARD
T&B TOP AND BOTTOM
TO TOP OF
TOC TOP OF CONCRETE
TOF TOP OF FOOTING
TOM TOP OF MASONRY
TOS TOP OF SLAB
TS THICKENED SLAB
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VEF VEHICLE EXHAUST FAN
VERT VERTICAL
WP WORKING POINT
WWF WELDED WIRE FABRIC
LIGHT GAUGE STEEL NOTES:
LG-1. WALL AND ROOF LAYOUT AND COMPONENTS SHOWN ON THE LAWN EQUIPMENT BUILDING
DRAWINGS ARE FOR GENERAL CONFIGURATION ONLY. THE CONTRACTOR SHALL BE RESPONSIBLE
FOR ALL DIMENSIONS, ELEVATIONS, CONNECTION DETAILS, QUANTITIES, ETC. NECESSARY FOR
THE COMPLETE DESIGN, FABRICATION, AND ERECTION OF THE TRUSS AND WALL SYSTEM. THE
CONTRACTOR SHALL COORDINATE THE DESIGN WITH THE ARCHITECTURAL PLANS, ELEVATIONS,
AND DETAILS. TRUSS AND WALL DESIGN SHALL BE COORDINATED WITH THE MECHANICAL
CONTRACTOR AND WEB MEMBERS SHALL BE COORDINATED TO ACCOMODATE EQUIPMENT,
DUCTS, AND PIPES, AS REQUIRED. COORDINATE MEP LAYOUTS WITH EQUIPMENT SUPPLIERS.
LG-2. LIGHT GAUGE FRAMING MEMBERS SHALL BE DESIGNED IN ACCORDANCE WITH THE AMERICAN IRON AND STEEL INSTITUTE (AISI) SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL
STRUCTURAL MEMBERS.
LG-3. ALL CALCULATIONS AND DRAWINGS USED IN THIS DESIGN MUST BE SIGNED AND STAMPED BY A PROFESSIONAL ENGINEER AND SUBMITTED FOR APPROVAL. IN ADDITION TO THE CALCULATIONS, THE SUBMITTAL SHALL INCLUDE DETAILS OF THE CONNECTIONS, ERECTION PLAN, LAYOUT, OUTRIGGERS, HEADERS, BRIDGING, AND BOTH TEMPORARY AND PERMANENT BRACING.
LG-4. THE CONTRACTOR SHALL SUBMIT COMPLETE PRODUCT CATALOGS FROM THE MATERIAL
MANUFACTURER FOR REVIEW PRIOR TO FABRICATION. THE CATALOGS SHALL INDICATE
QUALIFICATION, MATERIAL SPECIFICATIONS, DESIGN REFERENCES, ETC.
LG-5. ALL COLD-FORMED STEEL MEMBERS, THEIR COMPONENTS, AND CONNECTION MATERIAL SHALL BE
GALVANIZED. PREPARE AND REPAIR DAMAGED GALVANIZED COATINGS ON FABRICATED AND
INSTALLED LIGHT GAUGE METAL FRAMING WITH GALVANIZING REPAIR PAINT ACCORDING TO ASTM
A780 AND/OR THE MANUFACTURER'S RECOMMENDATIONS.
LG-6. COLD-FORMED STEEL MEMBERS SHALL BE Fy=33KSI FOR MEMBERS 43 MILS (18 GA) AND Fy=50KSI
FOR MEMBERS 54 MILS (16 GA) AND HEAVIER.
LG-7. ALL WELDING OF LIGHT GAUGE STEEL SHALL COMPLY WITH AWS D1.1 AND AWS D1.3 FOR WELDING
BASE MATERIAL LESS THAN 1/8" THICK.
LG-8. TRUSS DEFLECTION LIMITS SHALL BE IN ACCORDANCE WITH IBC 2015.
LG-9. BRIDGING AND BRACING OF TRUSS COMPRESSION MEMBERS SHALL BE INSTALLED IN
ACCORDANCE WITH THE TRUSS MANUFACTURERS DESIGN AND DIRECTIONS. TRUSSES SHALL BE
BRACED SECURELY BOTH DURING ERECTION AND AFTER PERMANENT INSTALLATION BY THE
CONTRACTOR. ERECTION BRACING SHALL HOLD TRUSSES STRAIGHT AND PLUMB UNTIL DECKING
AND PERMANENT TRUSS BRACING HAVE BEEN INSTALLED. ALL BRACING SHALL BE INSTALLED
PRIOR TO THE LOADING OF THE TRUSSES. THE BOTTOM CHORD SHALL NOT BE ASSUMED TO BE
LATERALLY SUPPORTED BY THE CEILING CONSTRUCTION.
LG-10 WALL LAYOUT SHOWN ON THE CIIP BUILDING DRAWINGS ARE FOR GENERAL CONFIGURATION
ONLY. THE CONTRACTOR SHALL COORDINATE THE DESIGN WITH ARCHITECTURAL, MECHANICAL
AND ELECTRICAL.
STEEL DECK NOTES:
SD-1. ROOF DECK SHALL BE GALVANIZED STEEL CONFORMING TO ASTM A653 WITH A MINIMUM YIELD
STRENGTH OF 33 KSI. STEEL ROOF DECK SHALL BE AS DESIGNED BY METAL BUILDING MFR.
FASTENERS FOR ROOF DECK SHALL UTILIZE A MINIMUM OF #12 SELF TAPPING SCREWS AT A PATTERN DETERMINED BY METAL BUILDING MFR TO SUPPORT STRUCTURE WITH #10 SELF TAPPING SCREWS AT SIDE LAP CONNECTIONS BY METAL BUILDING MFR. STEEL ROOF DECK AT LAWN EQUIPMENT BUILDING SHALL BE 1 1/2" WIDE RIB 22 GA. FASTENERS FOR ROOF DECK SHALL UTILIZE A MINIMUM OF #12 SELF TAPPING SCREWS AT A 36/5 PATTERN TO SUPPORT STRUCTURE WITH 2 #10 SELF TAPPING SCREWS AT
SIDE LAP CONNECTIONS. AT DECK EDGES FASTEN WITH #12 SCREWS AT 6" OC.
SD-2. PROVIDE ALL RIDGE PLATES, VALLEY PLATES, CLOSURE PLATES, POUR STOPS, AND ALL OTHER
ACCESSORIES REQUIRED FOR COMPLETE INSTALLATION IN ACCORDANCE WITH THE DECK
MANUFACTURER'S RECOMMENDATIONS.
SD-3. CONTRACTOR SHALL COORDINATE OPENINGS IN STEEL DECK WITH ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS PRIOR TO DECK PLACEMENT.
SD-4. HANGING LOADS DIRECTLY FROM ROOF DECK IS PROHIBITED.
SD-5. STEEL DECK SHALL SPAN CONTINUOUSLY OVER A MINIMUM OF 4 SUPPORTS (3 SPANS) UNO.
SPECIAL INSPECTION NOTES:
SI-1. INSPECTION OF FABRICATORS SHALL BE CONDUCTED IN ACCORDANCE WITH IBC 2015,
SECTION 1704.2.5.
SI-2. INSPECTION OF STEEL CONSTRUCTION SHALL BE CONDUCTED IN ACCORDANCE WITH IBC 2015, SECTION 1705.2.
SI-3. INSPECTION OF CONCRETE CONSTRUCTION SHALL BE CONDUCTED IN ACCORDANCE WITH
IBC 2015, SECTION 1705.3 AND TABLE 1705.3.
SI-4. INSPECTION OF MASONRY CONSTRUCTION SHALL BE CONDUCTED IN ACCORDANCE WITH
IBC 2015, SECTION 1705.4.
SI-5. INSPECTIONS FOR WIND AND SEISMIC RESISTANCE SHALL BE AS PER IBC 2015,
SECTION 1705.11 AND 1705.12.
SI-6. INCLUDE SPECIAL INSPECTIONS REQUIREMENTS IN CONTRACTOR'S QUALITY
CONTROL (CQC)PLAN.
SI-7. THE CONTRACTOR SHALL RETAIN THIRD PARTY QUALITY CONTROL AGENCIES TO CONDUCT
SPECIAL INSPECTIONS REQUIRED BY IBC. INSPECTING AGENCY SHALL PROVIDE REPORTS OF
SPECIAL INSPECTIONS DIRECTLY TO THE GOVERNMENT.
WOOD NOTES:
W-1. LAYOUT AND DIMENSIONS OF FRAMING MEMBERS ON STRUCTURAL DRAWINGS SHOW GENERAL
ARRANGEMENT. COORDINATE WITH ARCHITECTURAL
W-2. ALL DIMENSIONAL LUMBER NOTED IN THE DRAWINGS SHALL PROVIDE NOT LESS THAN THE MINIMUM
DESIGN VALUES AS PUBLISHED BY THE NATIONAL DESIGN SPECIFICATION.
W-3. NO HOLES, COPES OR CUTS ARE PERMITTED IN STRUCTURAL WOOD FRAMING.
W-4 ALL FASTENING OF WOOD MEMBERS SHALL BE IN ACCORDANCE WITH THE DETAILS OR ICC IBC
FASTENING SCHEDULE, WHICHEVER IS MORE STRINGENT.
W-5 ALL LUMBER SHALL BE KILN DRIED WITH A MOISTURE CONTENT LESS THAN 19%.
W-6 ALL FASTENER COATINGS SHALL BE COMPATIBLE WITH WOOD PRESERVATIVE USED.
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\k6enxmdz\Documents\FY18JA76149_RECEPTION COMPLEX_STRUC_R18_k6enxmdz.rvt
6/13/2019 1:54:28 PM
JU
N
E
W
2H P1
9R
M . Z
AI
TZ
P.
S
U
LL
IV
AN
2-
-0
S-001
G
EN
ER
AL
S
TR
U C
TU
R
AL
N
O
TE
S
C H
AR
LE
ST
O
N D
IS
TR
IC
T
H
AG
O
O D
A
VE
N U
E C
H
AR
LE
ST
O N
, S C
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
FO
R
T
JA
C
KS
O N
, S O
U
TH
C
AR
O
LI
N A
R
EC
EP
TI
O N
C O
M
PL
EX
P
H
AS
E
FY
8, P
N
VO
LU
M E
-C
LO
TH
IN
G
IN
IT
IA
L
IS
SU
E
PO
IN
T
(C
IIP
J.
W
H
IT
TA
KE
R
ISSUE FOR CONSTRUCTION
M
AR
K D
ES
C
R
IP
TI
O
N D
+16 / -39
ZONE
ROOF
CIIP BUILDING HIGH ROOF
C AND C WIND PRESSURES (PSF)
ULTIMATE
10 SF
EFFECTIVE
WIND
AREA 1
WALLOVERHANG
1. GROSS WIND PRESSURES SHOWN ABOVE CORRESPOND TO WIND
PRESSURE DIAGRAMS.
2. EDGE ZONES 'a' = 17'-0"
3. WIND PRESSURES SHOWN SHALL BE USED IN CONJUNCTION WITH LOAD
COMBINATIONS SPECIFIED IN SECTIONS 2.3 AND 2.4 OF ASCE 7-10.
4. NEGATIVE WIND PRESSURES REPRESENT WIND PRESSURES ACTING AWAY
FROM THE COMPONENT AND CLADDING SURFACES.
5. SEE S-101X FOR PRESSURES ONS LAWN EQUIPMENT BUILDING.
6. CANOPIES SSHALL USE OVERHANG PRESSURES FOR ZONE INDICATED.
20 SF
50 SF
100 SF
+14 / -38
+13 / -37
+12 / -36
+16 / -65
+14 / -59
+13 / -49
+12 / -42
+16 / -98
+14 / -80
+13 / -59
+12 / -42
+39 / -42
+37 / -41
+35 / -39
+32 / -37
+39 / -52
+37 / -49
+35 / -44
+32 / -42
-62 -98
-78
-52
-32
ZONE 2 ZONE 3 ZONE 4 ZONE 5ZONE 2 ZONE 31 &
-60
-59
-59
+15 / -36
ZONE
ROOF
CIIP BUILDING LOW ROOF
C AND C WIND PRESSURES (PSF)
ULTIMATE
10 SF
EFFECTIVE
WIND
AREA 1
WALLOVERHANG
20 SF
50 SF
100 SF
+13 / -35
+12 / -33
+12 / -33
+15 / -59
+13 / -53
+12 / -45
+12 / -39
+15 / -89
+13 / -73
+12 / -53
+12 / -39
+36 / -39
+33 / -37
+32 / -36
+30 / -33
+36 / -47
+33 / -45
+32 / -40
+30 / -39
-46 -89
-71
-47
-43
ZONE 2 ZONE 3 ZONE 4 ZONE 5ZONE 2 ZONE 31 &
-44
-43
-43
+29 / -27
ZONE
ROOF
FORMATION AREA
C AND C WIND PRESSURES (PSF)
ULTIMATE
36 SF
EFFECTIV
E WIND
AREA 1
1. GROSS WIND PRESSURES SHOWN ABOVE CORRESPOND
TO WIND PRESSURE DIAGRAMS SHOWN BELOW.
2. EDGE ZONES 'a' = 6'-0" 1/12 SLOPE
3. WIND PRESSURES SHOWN SHALL BE USED IN
CONJUNCTION WITH LOAD COMBINATIONS SPECIFIED IN
SECTIONS 2.3 AND 2.4 OF ASCE 7-10.
4. NEGATIVE WIND PRESSURES REPRESENT GOVERNING
WIND PRESSURES ACTING AWAY FROM THE COMPONENT
AND CLADDING SURFACES.
144 SF
>144 SF
+29 / -27
+29 / -27
+44 / -42
+44 / -42
+29 / -27
+59 / -81
+44 / -42
+29 / -27
ZONE 2 ZONE 32
2 2 2 2
2 2 2 2
1 1
1 1
3 3
'a' = 17'
(TYP)
'a' = 17'
(TYP)
'a'
'a' = 17'
(TYP)
'a' = 17'
(TYP)
WALL ZONES
ROOF ZONES
HIGH ROOF
LOW ROOF
3 32 3 32
'a
TY
P)
'a
'a'
CANOPY, TYP
3 3
6.3 PSF
21 PSF
1.9 PSF
FROM RIDGE
31' - 0"
UNBALANCED SNOW LOAD
CIIP BUILDING
7.6 PSF
13.3 PSF
2.3 PSF
FROM RIDGE
12' - 0"
UNBALANCED SNOW LOAD
FORMATION AREA
11' - 4"
6.3 PSF
6.3 PSF
43.3 PSF MAX INTENSITY OF SURCHARGE LOAD
SNOW DRIFT LOADING
(HIGH ROOF / LOW ROOF)
CIIP BUILDING
NOTE: THIS LOAD CASE SHALL BE MIRRORED ABOUT RIDGE.
NOTE: THIS LOAD CASE SHALL BE MIRRORED ABOUT RIDGE.
E
FOR CANOPY SIZE
SEE ARCH
36 PSF
6.3 PSF
50 PSF MAX INTENSITY OF SURCHARGE LOAD
SNOW DRIFT LOADING
(CANOPIES)
E
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\k6enxmdz\Documents\FY18JA76149_RECEPTION COMPLEX_STRUC_R18_k6enxmdz.rvt
6/13/2019 1:54:42 PM
JU
N
E
W
2H P1
9R
M . Z
AI
TZ
P.
S
U
LL
IV
AN
2-
-0
S-002
G
EN
ER
AL
S
TR
U C
TU
R
AL
N
O
TE
S
C H
AR
LE
ST
O
N D
IS
TR
IC
T
H
AG
O
O D
A
VE
N U
E C
H
AR
LE
ST
O N
, S C
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
FO
R
T
JA
C
KS
O N
, S O
U
TH
C
AR
O
LI
N A
R
EC
EP
TI
O N
C O
M
PL
EX
P
H
AS
E
FY
8, P
N
VO
LU
M E
-C
LO
TH
IN
G
IN
IT
IA
L
IS
SU
E
PO
IN
T
(C
IIP
J.
W
H
IT
TA
KE
R
ISSUE FOR CONSTRUCTION
COMPONENT AND CLADDING WIND PRESSURES2UNBALANCED SNOW LOADING DIAGRAMS1
M
AR
K D
ES
C
R
IP
TI
O
N D
K
1 6
CA
CB
C1 C6
OUT TO OUT OF STEEL COLUMNS
296' - 5 1/2"
O U
T
TO
O U
T O
F
ST
EE
L
C O
LU
M
N S
3'
1/ 2"
132' - 0"
SF302
SF303
SF303
SF301
SF302
SF301
BRACED BAY BRACED BAY
BRACED BAY BRACED BAY
BR
AC
ED
B
AY
BR
AC
ED
B
AY
BR
AC
ED
B
AY
BR
AC
ED
B
AY
MATCHLINE
MATCHLINE
M
AT
C H
LI
N
E
MATCHLINE
M
AT
C H
LI
N
E
MATCHLINE
SF304
SF304
FOUNDATION PLAN NOTES:
1. FOR GENERAL STRUCTURAL NOTES AND ABBREVIATIONS, SEE S-001.
2. SEE SF301 AND FOLLOWING FOR FRAME SECTIONS.
3. SEE SB501 AND FOLLOWING FOR SLAB AND FOUNDATION SECTIONS AND
DETAILS.
4. P-X INDICATES CONCRETE PIER. SEE PIER SCHEDULE ON SB602 FOR
SIZE AND REINFORCEMENT.
5. CF-X.Y INDICATES COLUMN FOOTING FOUNDED IN SOIL WITH AN
ALLOWABLE BEARING CAPACITY OF 3000 PSF AS DEFINED IN THE
FOUNDATION NOTES ON S-001. SEE FOOTING SCHEDULE ON SB601 FOR
SIZE AND REINFORCEMENT.
6. TOP OF INT FTG = (-) 2'-0" UNO
TOP OF EXT FTG = (-) 2'-0" UNO
TOP OF FORMATION AREA FTG = (-) 1'-4" MIN.
7. PIERS AND FOUNDATIONS SUPPORTING MB COLUMNS ARE PRELIMINARY
FOR ESTIMATING PURPOSES ONLY AND ARE NOT FINAL. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR FINAL DESIGN OF MB PIERS
AND FOUNDATIONS BASED ON FINAL MB REACTIONS. SEE GENERAL
NOTES FOR ADDITIONAL INFORMATION.
8. COORDINATE UNDERGROUND UTILITY LINES WITH CIVIL, ELECTRICAL
PLUMBING, AND FIRE PROTECTION DRAWINGS PRIOR TO
CONSTRUCTION OF FOOTINGS AND SLABS-ON-GRADE.
9. * INDICATES DIMENSION SHALL BE COORDINATED WITH METAL BUILDING
MANUFACTURER.
10. INDICATES FOOTING STEP. SEE DETAIL 6/SB502 .
11. DRAINAGE AND DEWATERING: ALL EXCAVATION SHALL BE PREFORMED
SO THAT THE SITE AND THE AREA IMMEDIATELY SURROUNDING THE SITE
WHICH AFFECTS CONSTRUCTION OPERATIONS WILL BE CONTINUALLY
AND EFFECTIVELY DRAINED. THE CONTRACTOR SHALL PROVIDE
DRAINAGE AND DEWATERING AS REQUIRED TO ENSURE THAT ALL
FOOTING EXCAVATIONS ARE ACCOMPLISHED WITH THE SUBGRADE
SOILS REMAINING DRY AND FIRM UNTIL AFTER FOOTINGS ARE PLACED
AND BACKFILLED. REMOVAL OF SURFACE WATER, GROUNDWATER, AND
ANY PERCHED-WATER CONDITIONS, WHICH MIGHT BE ENCOUNTERED
DURING…