W912HN-20-B-3002_VOL2_AMD3.PDF
PDF 3 MB Posted
- Solicitation number
- W912HN20B3002
About this file
This document package includes plans and specifications for a telecommunications infrastructure upgrade project at Moody Air Force Base. The solicitation was posted on June 23, 2020 as a full and open competition under number W912HN20B3002 with a bid opening date of June 23, 2020 at 2:00pm Eastern Time. The project involves installing new fiber optic and copper cabling as well as upgrading telecommunications rooms and equipment cabinets. Sheet TS102 provides a site plan detailing locations for new manholes, ductbanks and cabling runs. Sheet T-201 includes rack elevations outlining equipment layouts for security, data and voice systems. Drawing TY601 is a security riser diagram. The specifications are intended for a construction contract award and completion of all telecommunications upgrades by the Department of the Army Corps of Engineers Savannah District.
View the file
Other files
Show all 35
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
H
Y
D
H Y D
S
G
H
Y
D
S
E
G
SS
MH
MH
MH
EX
IS
TI
NG
S
AN
IT
AR
Y
SE
W
ER
P
IP
IN
G
EXISTING SANITARY SEWER PIPING
EX
IS
TI
NG
W
AT
ER
M
AI
N
EXISTING WATER MAIN
EX
IS
TI
NG
N
AT
UR
AL
G
AS
P
IP
IN
G
EXISTING NATURAL GAS PIPING
SIJAN ST.
D
E TSW E
MMETER
RPZ
BFP
METER
RPZ
BFP
CM1
CM2
C
C
COMM
COMM COMM COMM COMM COMM
C O
M M
C O
M M
C O
M M
C O
M M
COMM
C C C
C
CC
C
COMM COMM
C O
M M
C O
M M
COMM
COMM
COMM
COMM
C O
M M
CM13CM12CM11
CM10
CM9
CM17
CM14
GENERAL NOTES THIS SHEET:
A SEE SHEET T-001 FOR LEGEND AND
GENERAL NOTES.
B SEE TY500 SERIES DRAWINGS FOR
ACS/IDS DETAILS.
C SEE TY601 FOR SECURITY SYSTEM
DIAGRAM.
D SEE SHEET E-509 FOR DUCTBANK
DETAILS
SHEET KEYNOTES:
1 PROVIDE CONNECTION TO BASE
TELECOMMUNICATIONS INFRASTRUCTURE
UPGRADE PROJECT MANHOLE. EXTEND ONE 12
STRAND SMFO CABLE IN 1-4" CONDUIT AND ONE
25 PAIR COPPER CABLE IN 1-4" CONDUIT VIA
EXISTING 4-WAY TELECOMMUNICATIONS
DUCTBANK.
2 4 WAY 4" DUCTBANK INTO BUILDING
COMMUNICATION ROOM. PROVIDE ONE 12
STRAND SMFO CABLE IN 1-4" CONDUIT AND
ONE 25 PAIR COPPER CABLE IN 1-4". PROVIDE
THREE-CELL FABRIC INNERDUCT IN OCCUPIED
DUCTS. PROVIDE PULL STRING IN SPARE
DUCT. REFER TO SHEET E-509 DETAIL 1 FOR
ADDITIONAL DUCTBANK INFORMATION.
3 4 WAY 4" DUCTBANK WITH ONE 12 STRAND SMFO
CABLE IN 1-4" CONDUIT AND ONE 25 PAIR
COPPER CABLE IN 1-4" CONDUIT. PROVIDE
THREE-CELL FABRIC INNERDUCT IN OCCUPIED
DUCTS. PROVIDE PULL STRING IN SPARE
DUCT. REFER TO SHEET E-509 DETAIL 1 FOR
ADDITIONAL DUCTBANK INFORMATION.
4 EXISTING COMMUNICATIONS MANHOLE.
5 PROVIDE COMMUNICATIONS MANHOLE.
6 EXISTING DUCTBANK TO REMAIN.
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
-D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
C
AT
EG
O
R Y
C O
D E:
1 2 3 4 5
A
GRAPHIC SCALES
M O
O D
Y
AF
B, G
A M
O O
D Y
AF
B
H
AN
G A
R /H
M U
SA
VA
N N
AH
D
IS
TR
IC
T
SA
VA
N N
AH
, G
EO
R
G
IA
AE
C
O M
S
ER
VI
C
E S, IN
C
S J
EF
FE
R
SO
N S
T
ST
E
R
O
AN
O
KE
V A
1-
JU
LY
2, 7 8 9 10
B
C
D
E
F
G
C S
R
N
1-
5-
W
2H N
-1 9-
R -3
ISSUED FOR CONSTRUCTION
TS102
TE
LE
C O
M M
U N
IC
AT
IO
N
S
SI
TE
P
LA
N
AS
T
C
LH
M H
C
1" = 30'-0"
TELECOMMUNICATIONS SITE PLAN 2
30' 15' 0 30' 60' 1"=30'
MATCHLINE-SEE SH TS101 MATCHLINE-SEE SH TS101
M
AR
K D
E
SC
R
IP
TI
O
N D
A
TE
R
EV
IS
ED
IA
W A
M
EN
D M
EN
T
7/
/2
6 6
SPACE
NETWORK VIDEO RECORDER
(4U)
WIRE MANAGER 2U
POE CCTV SWITCH
2 - 48-PORT PATCHPANEL
VERTICAL WIRE MANAGER (45U)
VERTICAL PDU
NVR
WIRE MANAGER
VMS VIDEO MANAGEMENT SERVER
(2U)
LAPTOP INTERFACE CCTV LAPTOP INTERFACE
DRAWER (2U)
SPACE VERTICAL PDU
45 12 PORT FIBER SPLICE /
PATCH PANEL 1U
SECURITY
UPS BATTERY
UPS BATTERY
UPS BATTERY
UPS BATTERY
UPS HEAD-END
POE CCTV SWITCH
UPS
DATA SWITCH 48 PORT DATA SWITCH, GFGI
2 - 48 PORT POE CCTV SWITCHES
S1
DATA SWITCH
WIRE MANAGER (2U)
VERTICAL PDU
48-PORT DATA SWITCH (NIC)
48-PORT PATCH PANEL (2U)
VERTICAL WIRE MANAGER (45U)
DATA SWITCH
WIRE MANAGER (2U)
48 PORT DATA SWITCH, NIC
48-PORT PATCH PANEL (2U)
DATA SWITCH
WIRE MANAGER (2U)
48 PORT DATA SWITCH, NIC
48-PORT PATCH PANEL (2U)
DATA SWITCH
WIRE MANAGER (2U)
48 PORT DATA SWITCH, NIC
48-PORT PATCH PANEL (2U)
KW VERTICAL PDU
COPPER PATCH PANEL COPPER PATCH PANEL
DATA
TERMINATE
INCOMING
CABLES HERE
3 - 12 PORT FIBER
SPLICE /
PATCH PANEL 1U
T1 AND T2
SPACE
POE VOICE SWITCH
12 PORT FIBER SPLICE /
PATCH PANEL 1U
SECURITY
24-PORT VOICE SWITCH 1U (NIC)
48-PORT PATCH PANEL 2U
POE DATA SWITCH 24-PORT VOICE SWITCH 1U
WIRE MANAGER 2U
24-PORT PATCH PANEL 1U (NIC)
WIRE MANAGER 2U
SPACE
SPACE
SPACE
POWER DISTRIBUTION
NOTE:
THIS ELEVATION IS TYPICAL OF
TWO WALL MOUNTED CABINETS.
1 LOCATED PUMP BUILDING AND 1 LOCATED
IN HANGAR RM 101.
W1 AND W2
SPACE
WIRE MANAGER 2U
24 PORT PATCHPANEL
VERTICAL WIRE MANAGER (45U)
VERTICAL PDU
WIRE MANAGER
LAPTOP INTERFACE CCTV LAPTOP INTERFACE
DRAWER (2U)
SPACE VERTICAL PDU
45 12 PORT FIBER SPLICE /
PATCH PANEL 1U
SECURITY
UPS BATTERY
UPS BATTERY
UPS BATTERY
UPS BATTERY
UPS HEAD-END
POE CCTV SWITCH
UPS
39 28 PORT POE CCTV SWITCHES
SPACE
SPACE
S2
DATA SWITCH
WIRE MANAGER (2U)
VERTICAL PDU
48-PORT DATA SWITCH, NIC
48-PORT PATCH PANEL (2U)
VERTICAL WIRE MANAGER (45U)
DATA SWITCH
WIRE MANAGER (2U)
48 PORT DATA SWITCH, NIC
48-PORT PATCH PANEL (2U)
DATA SWITCH
WIRE MANAGER (2U)
48 PORT DATA SWITCH, NIC
48-PORT PATCH PANEL (2U)
DATA SWITCH
WIRE MANAGER (2U)
48 PORT DATA SWITCH, NIC
48-PORT PATCH PANEL (2U)
KW VERTICAL PDU
COPPER PATCH PANEL COPPER PATCH PANEL
DATA
TERMINATE
INCOMING
CABLES HERE
2 - 12 PORT FIBER
SPLICE /
PATCH PANEL 1U
T3 AND T4
POWER DISTRIBUTION
WIRELESS MIC RECEIVER(NIC)
T/X INTERFACES(NIC) 4K DGE(NIC)
BLURAY DVD MEDIA PLAYER(NIC)
DIGITAL HD VIDEO PROCESSOR(NIC)
GFE PC WORKSTATION(NIC)
GFE PC WORKSTATION(NIC)
UPS
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
-D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
C
AT
EG
O
R Y
C O
D E:
1 2 3 4 5
A
M O
O D
Y
AF
B, G
A M
O O
D Y
AF
B
H
AN
G A
R /H
M U
SA
VA
N N
AH
D
IS
TR
IC
T
SA
VA
N N
AH
, G
EO
R
G
IA
AE
C
O M
S
ER
VI
C
E S, IN
C
S J
EF
FE
R
SO
N S
T
ST
E
R
O
AN
O
KE
V A
1-
JU
LY
2, 7 8 9 10
B
C
D
E
F
G
C S
R
1-
5-
W
2H N
-1 9-
R -3
ISSUED FOR CONSTRUCTION
T-201
TE
LE
C O
M M
U N
IC
AT
IO
N
S R
AC
K
EL
EV
AT
IO
N S
AS
T
C
LH
M H
C
NO SCALET-201
1 SECURITY CABINET ELEVATION - RM 136
NO SCALET-201
2 TELECOM CABINET ELEVATION - RM 136
NO SCALET-201
WALL MOUNTED TELECOM CABINET
ELEVATION - PUMP BUILDING & HANGAR RM
NOTE:
THIS ELEVATION TYPICAL OF 2 CABINETS
IN ROOM 136.
NO SCALET-201
4 SECURITY CABINET ELEVATION - RM 217
NO SCALET-201
5 TELECOM CABINET ELEVATION - RM 217
NOTE:
THIS ELEVATION TYPICAL OF 2 CABINETS
IN ROOM 136.
M
AR
K D
E
SC
R
IP
TI
O
N D
A
TE
R
EV
IS
ED
IA
W A
M
EN
D M
EN
T
7/
/2
R
EV
IS
ED
IA
W
A M
EN
D
M
EN
T
7/
/2
NO SCALET-201
6 AV RACK ELEVATION CONFERENCE ROOM
RM 136
CEILING
FIRST FLOOR
SECURITY
CABINET
AJB
BMS
EL
CR
EXT
RM 102
BMS
AO AO
RM 104 RM 104A
AJB
BMS
AJB
AO
RM 107
AJB
BMS
EL
CR
RM 109
BMS
CL
AJB
BMS
EL
CR
RM 109A
BMS
AJB
BMS
EL
CR
RM 109B
BMS
CL
RM 112A
AJB
BMS
AJB
BMS
EL
CR
RM 114
EXT
AJB
BMS
EL
RM 114A
AJB
BMS
EL
CR
RM 116
BMS
AJB
BMS
EXT
AJB
BMS
EXT
AJB
BMS
EXT
RM 101
AJB
BMS
EL
CR
EXT
RM 134
AJB
BMS
EL
CR
RM 118
CL
EXT
AJB
BMS
EL
CR
CL
EXT
AJB
BMS
BMS
EXT
RM 123
AJB
BMS
EL
CR
CL
EXT
AJB
BMS
EL
CR
CL
RM 124
BMS
AJB
BMS
BMS
EXT
RM 125
AJB
BMS
BMS
EXT
RM 126
AJB
BMS
EXT
AJB
BMS
EL
CR
RM 128
EXT
FI
R
ST
F
LO
O
R
SE
C U
R
IT
Y R
IS
ER
C O
N
TI
N U
ED
BE
LO
W
FI
R
ST
F
LO
O
R
SE
C U
R
IT
Y R
IS
ER
C O
N
TI
N U
ED
FR
O M
A
BO
VE
RM 217
CEILING
SECOND FLOOR
SECURITY
CABINET
RM 214RM 202
AJB
BMS
EL
CR
CL
REX REX REX REX
REX REX REX
EL
CR
REX
GENERAL NOTES THIS SHEET:
A PROVIDE ALL CABLING, CONNECTIONS AND
APPURTENANCES NECCESSARY FOR A
COMPLETE AND USABLE SYSTEM.
COORDINATE CABLING TYPE WITH
MANUFACTURER'S RECOMMENDATIONS.
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
-D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
C
AT
EG
O
R Y
C O
D E:
1 2 3 4 5
A
M O
O D
Y
AF
B, G
A M
O O
D Y
AF
B
H
AN
G A
R /H
M U
SA
VA
N N
AH
D
IS
TR
IC
T
SA
VA
N N
AH
, G
EO
R
G
IA
AE
C
O M
S
ER
VI
C
E S, IN
C
S J
EF
FE
R
SO
N S
T
ST
E
R
O
AN
O
KE
V A
1-
JU
LY
2, 7 8 9 10
B
C
D
E
F
G
C S
R
1-
5-
W
2H N
-1 9-
R -3
ISSUED FOR CONSTRUCTION
TY601
SE
C
U R
IT
Y
SY
ST
EM
S
R
IS
ER
D
IA
G
R
AM
AS
T
C
LH
M H
C
NO SCALETY601
1 SECURITY RISER DIAGRAM
M
AR
K D
E
SC
R
IP
TI
O
N D
A
TE
R
EV
IS
ED
IA
W A
M
EN
D M
EN
T
7/
/2
| TS102 TELECOMMUNICATIONS SITE PLAN 2 |
| T-201 TELECOMMUNICATIONS RACK ELEVATIONS |
| TY601 SECURITY SYSTEMS RISER DIAGRAM |
File details come from the government source that posted it. Updated .