W912HN-20-B-3002_AMD2_VOLUME2.PDF
PDF 5 MB Posted
- Solicitation number
- W912HN20B3002
About this file
This package includes construction drawings and specifications for a personnel recovery hangar project at Moody Air Force Base. The documents outline requirements for site utilities including a compressed air system, natural gas meter, rainwater cistern, piping details and telecommunications infrastructure. Telecommunications drawings show rack elevations, outlet details, cabling diagrams and notes specifying compliance with BICSI and TIA standards. Requirements include installing copper and fiber optic cabling, data switches, patch panels, voice equipment and security cameras. A solicitation was issued on June 23, 2020 for the project with an opening date of June 23 at 2:00pm Eastern Time. The Corps of Engineers Engineering District Savannah is the contracting agency.
View the file
Other files
Show all 35
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AF
F
AF
F DISCHARGE
EYEWASH
ON FLOOR
SHOWER HEAD
SHOWER
OPERATOR
EYEWASH
BOWL &
HEADS
EYEWASH
OPERATOR
LIGHT
HORN
SILENCE SWITCH
TO PWR SOURCE
FLOW SWITCH
FLOOR
TEPID WATER
CAP
DIRT LEG
UNION
FINAL
CONNECTION TO
EQUIPMENT
6" MIN
GAS REGULATOR. ROUTE
VENT TO EXTERIOR.
GAS RATED
PLUG VALVE
GAS LINE TO EQUIPMENT,
SIZE AS INDICATED ON
FLOOR PLAN
GAS SUPPLY LINE AT OR
ABOVE CEILING
G
G
CAT-1
DRY TANK
TO SYSTEM
CA
CONC PAD
PRESSURE GAUGE (TYP)
FD
D
NOTE 2 (FOR ALL DRAINS)
CONC PAD
AC-1
PRESSURE
REGULATOR
SET AT 120
D
ACD-1
UNION (TYP)
D
NORMALLY
CLOSED
BYPASS
CAT-1
WET TANK
CONC PAD
D
NOTE 1
NOTES:
1. PROVIDE CONDENSATE MANAGEMENT SYSTEM TO REMOVE OIL BEFORE DISCHARGING TO SANITARY. BASIS OF
DESIGN: KAESER KCF 100.
2. PROVIDE AUTOMATIC CONDENSATE DRAIN FOR ALL EQUIPMENT. BASIS OF DESIGN: KAESER AMD 6550.
3. PROVIDE INLINE PARTICULATE FILTER. BASIS OF DESIGN: KAESER KB-F83
4. COMPRESSED AIR PIPING CONFIGURATION MAY VARY BY MANUFACTURER. CONTRACTOR SHALL INSTALL THE PIPING
AND PROVIDE ALL COMPONENTS IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATION.
5. PROVIDE MOISTURE SEPARATOR FILTER.
6. AIR COMPRESSOR SHALL HAVE INTEGRAL AFTERCOOLER. AFTERCOOLER APPROACH TEMPERATURE SHALL BE 15 °F
OR LESS.
NOTE 5 NOTE 3
2" CA
2" CA
2" CA
2" CA
2" CA
2" CA
GAS METER
GAS SUPPLY
FROM UTILITY (1900
CFH)
BY UTILITY
TO BUILDING
REGULATOR SIZED FOR
14 IN WC OUTLET PRESSURE
VALVE (TYP)
NOTES:
1. CONNECT GAS METER TO EMCS.
DRIP LEG
(TYP)
NOTES:
1. DETAIL IS DIAGRAMTIC ONLY.
2. REFER TO SPECIFICATIONS FOR ALL NECESSARY COMPONENTS.
3. ALL COMPONENTS SHOWN ABOVE ON HOUSEKEEPING PAD SHALL BE PROVIDED AS A SYSTEM COMPLETE WITH ALL THE EQUIPMENT SHOWN. SEE P601 FOR DETAILS ON REQUIRED BOOSTER PUMP AND
FLOW RATE.
4. PROVIDE WATER METER BY UTILITY COMPANY AND CONNECT TO EMCS.
5. PROVIDE 1500 WATT DE-ICING HEATER WITH STAND.
6. PROVIDE 1-INCH THICK INSULATION WITH R-VALUE 6 OR GREATER AND PVC OR ALUMINUM JACKETING.
7. REFER TO MECHANICAL DRAWINGS FOR CONTROL MONITORING POINTS REQUIRED FOR RAINWATER SYSTEM.
8. PROVIDE ROUND DOWNSPOUT FOR ALL OUTLETS OF FLUSH FILTER. MATERIAL AND COLOR TO MATCH ROOF DOWNSPOUT.
STORM WATER
DOWNSPOUT
FROM ROOF. SEE
ARCHITECTURE
TO STORM, PROVIDE
DOWNSPOUT BOOT
FOR CONNECTION TO
UNDERGROUND.
NOTE 8
TANK OVERFLOW
TO STORM, NOTE 8
TO FIXTURES
FLOOR
CONC PAD (TYP)
FLOAT FILTER
SMOOTHING INLET
FLOAT SWITCH
FOR PUMP
PROTECTION
RWT-1
HT-1
RBP-1
RFS-1
FF-1 DOMESTIC COLD WATER
NOTE 5
CHECK VALVE
BACKFLOW PREVENTER
M
NOTE 4
UNION (TYP)
NOTE 6
SOLENOID VALVE BY
MANUFACTURE. SET TO
OPEN WHEN RAINWATER
TANK IS EMPTY.
VENT
CONNECT PER MANUFACTURER'S RECOMMENDATION.
RBP-1
CHECK VALVE (TYP)
ROUND DOWNSPOUT, MIN.
20" BEFORE FILTER INLET
ELECTRICAL WIRE BONDING
STRAP OR #6 WIRE (COPPER)
COPPER PIPING
METRAFLEX OR EQUAL
EXPANSION FITTING.
SEE NOTE #1
NOTES:
1. PROVIDE MINIMUM 2" EXPANSION FITTING MOVEMENT.
2. SEE PLANS FOR ANCHOR LOCATIONS.
PIPE GUIDE (TYP)
4x PIPE DIA.
4x PIPE DIA.
SECURE MEMBER TO
STRUCTURAL STEEL/
CONCRETE PER
SPECIFICATIONS
SPIDER TYPE PIPE
GUIDE BOLTED TO
CHANNEL
2x2x1/4 ANGLE IRON MEMBER
AT EACH END OF THE
TRAPEZE. TWO REQUIRED PER
GUIDE.
4x2x1/4 CHANNEL
IRON TRAPEZE
UNDER ALL PIPES
2x2x1/4 ANGLE IRON
THRUST MEMBERS AT
EACH END OF TRAPEZE.
FOUR REQUIRED PER
ANCHOR
SECURE THRUST MEMBERS TO
STRUCTURAL
STEEL/CONCRETE PER
SPECIFICATIONS
DOUBLE CLAMP PIPE ANCHOR WELDED TO
CHANNEL
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
A N
SI
-D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
C
AT
EG
O
R Y
C O
D E:
1 2 3 4 5
A
M O
O D
Y
AF
B, G
A M
O O
D Y
AF
B
H
AN
G
AR
/H M
U
SA
VA
N N
AH
D
IS
TR
IC
T
SA
VA
N N
AH
, G
EO
R
G
IA
AE
C
O M
S
ER
VI
C
E S, IN
C
S J
E
FF
ER
SO
N S
T
ST
E
R
O
AN
O
KE
V A
1-
JU
LY
2, 7 8 9 10
B
C
D
E
F
G
C
SR
1-
5-
W
2H N
-1 9-
R -3
ISSUED FOR CONSTRUCTION
P-502
D
ET
AI
LS
JM
L
JM
L
N
SL
NO SCALEP-502
4 EMERGENCY SHOWER DETAIL
NO SCALEP-502
2 EQUIPMENT GAS CONNECTION DETAIL
NO SCALEP-502
7 COMPRESSED AIR SYSTEM DETAIL
NO SCALEP-502
5 NATURAL GAS METER DETAIL
NO SCALEP-502
1 RAINWATER CISTERN TANK DETAIL
NO SCALEP-502
6 PIPING EXPANSION JOINT DETAIL
M
AR
K D
E
SC
R
IP
TI
O
N D
A
TE
R
EV
IS
ED
IA
W A
M M
EN
D
M
EN
T
/1 7/
1/8" = 1'-0"P-502
3 PIPE ANCHOR DETAIL
OUTLET BOX FOR GFGI CLOCK WITH CONDUIT TO BELOW RAISED ACCESS FLOOR.
MOUNT AT 7'-6" AFF.
TELECOM AND SECURITY LEGEND
DATA / VOICE OUTLET WITH 1' EMT CONDUIT. MH 18" AFF UNLESS OTHERWISE NOTED.
SUBSCRIPTS INDICATE THE FOLLOWING NETWORK TYPE:
SEE SHEET T-502 - T-503 FOR PLATE DETAIL.
W - DENOTES WALL PHONE WITH MOUNTING STUDS.
HORIZONTAL MESH CABLE TRAY. SIZE AS INDICATED, MH 12" MIN. ABOVE CEILING
UNLESS OTHERWISE NOTED.
DATA OUTLET, MH 52" AFF UNLESS OTHERWISE NOTED WITH 1" EMT CONDUIT.
SEE SHEET T-502 - T-503 FOR PLATE DETAIL.
3/4" THICK x 96" TALL THICK PAINTED, FIRE RETARDANT PLYWOOD
TELECOMMUNICATIONS BACKBOARD. MOUNT BOTTOM AT 0'-6" AFF.
COMBINATION DATA/POWER FLOOR BOX.
SEE SHEET T-502 - T-503 FOR PLATE DETAIL.
JUNCTION BOX, PULL BOX, AND OR OUTLET. PROVIDE CABLES, CONNECTORS, CONDUIT,
FLEXIBLE CONDUIT, FITTINGS, ETC. LEG INDICATES WALL MOUNTED, CIRCLE INDICATES
CEILING MOUNTED, AND SQUARE INDICATES FLOOR MOUNTED.
PROVIDE OUTLET AND PATHWAY FOR AV EQUIPMENT WITH PULL STRING FOR AV ONLY.
FOR AV LOCATIONS PROVIDE 2 GANG BACKBOX WITH 1 1/4 IN EMT CONDUIT.
'P' DENOTES PROJECTOR
'D' DENOTES DISPLAY
'S' DENOTES SPEAKER
CONFIGURATION AND SHEET IN204, DETAIL 9 FOR TYPICAL THREE
DISPLAY MOUNTING CONFIGURATION.
J J
AV
TELECOM AND SECURITY GENERAL AND DEMOLITION NOTES
1 MOUNT DATA OUTLET BOXES AT SAME HEIGHT AS ELECTRICAL OUTLETS UON .
2. MOUNT OUTLET BOXES SO THAT NONE OCCUR BACK TO BACK IN WALLS.
3. INSTALLATION OF CABLE PATHWAYS AND DEVICES SHALL BE IN COMPLIANCE WITH NFPA 70, TIA-569-D, AND 13A.
4. TELECOMMUNICATIONS GROUNDING AND BONDING SHALL BE IN COMPLIANCE WITH NFPA 70 AND
TIA-607-C.
5. PROVIDE PULL STRING IN ALL EMPTY CONDUITS SERVING GOVERNMENT INSTALLED EQUIPMENT.
PULL STRING TO BE RATED FOR 200 LBS.
6. COORDINIATE FINAL LOCATIONS OF ALL EQUIPMENT WITH ARCHITECTURAL ELEVATIONS,
REFLECTED AND REFLECTED CEILING PLANS.
7. ALL COPPER TERMINATION HARDWARE TO BE 110 STYLE IDC UON. TERMINATION FOR VOICE
CABLES SHOULD BE EQUIVALENT TO AT&T TYPE 66MI-50.
8. TERMINATE ALL CABLES AND PROVIDE CROSS-CONNECTS AS NEEDED.
9. MONITOR CABLE PULL TENSION TO ENSURE MANUFACTURER RECOMMENDATIONS AND INDUSTRY
STANDARDS ARE NOT EXCEEDED.
10. PROVIDE PULL BOXES IN CONDUITS NO MORE THAN 100-FEET APART AND PER EVERY 180
DEGREES OF BEND.
11. SEE AD SERIES SHEETS FOR DEMOLITION NOTES AND REQUIREMENTS.
12. ADMINISTRATION STANDARD FOR TELECOMMUNICATION INFRASTRUCTURE SHALL COMPLY WITH
TIA-606-B.
13. SEAL PENETRATIONS THROUGH FLOORS OR FIREWALLS AND ALL SIDES OF TELECOMMUNICATIONS
ROOMS TO MAINTAIN THE INTEGRITY OF THE FIRE AND ACOUSTIC RATINGS.
14. LOCATE ALL PATWAYS AND CONVEYANCES TO AVOID INTERFERENCE WITH DUCTS, PIPES,
MECHANICAL EQUIPMENT, WITH REMOVAL OF CEILINGS TILES OR WITH ACCESS TO EQUIPMENT
WHICH REQUIRES MAINTENANCE.
15. TELECOMMUNICATIONS CABLING SHALL BE IN COMPLIANCE WITH TIA-568 STANDARDS AND 13A.
16. MOUNTING HEIGHT, UNLESS OTHERWISE NOTED IS TO CENTERLINE OF EQUIPMENT.
WAP OUTLET FOR CEILING MOUNTED WIRELESS ACCESS POINT WITH 1" EMT CONDUIT.
(GFGI) GOVERNMENT FURNISHED GOVERNMENT INSTALLED
C
NETWORK COLOR CODE:
GREEN - NIPRNET (UNCLASSIFIED)
AV
S
AV
D
CCTV CAMERA WITH MINIMUM 1" EMT CONDUIT.
EXT - INDICATES LOCATED ON EXTERIOR
CR CARD READER WITH MINIMUM 3/4" EMT CONDUIT AND PULL STRING.
BL EMERGENCY BLUELIGHT. PROVIDE 1" CONDUIT WITH PULL STRING FROM OUTLET BOX
TO CABLE TRAY.
PB DOOR RELEASE PUSH BUTTON.
AO AUTOMATIC DOOR OPEN PUSHBUTTON
EMERGENCY DOOR RELEASEREX
EP EMERGENCY PHONE, DOUBLE GANG JUNCTION BOX
IC INTERCOM. PROVIDE 1" CONDUIT WITH PULL STRING FROM OUTLET BOX TO CABLE TRAY.
MAGNETIC HOLD OPEN
CATV OUTLET
TELECOMMUNICATIONS OUTLET, CEILING MOUNTED.
TELECOM SITE
EXISTING TELECOMMUNICATIONS LINE.
DEMOLITION TELECOMMUNICATIONS LINE.COMM
COMM
TELECOMMUNICATIONS LINE.
BMS BALANCED MAGNETIC SWITCH
EL ELECTRIC LATCH
CL CIPHER LOCK
PA
PUBLIC ADDRESS SPEAKER WITH MINIMUM 1" EMT CONDUIT AND PULL STRING. SPEAKER
IS NOT IN CONTRACT.
'H' DENOTES HORN TYPE
MH
TV
H
C P WALL MOUNTED DUAL FURNITURE CONNECTION POWER / DATA
AJB ACS JUNCTION BOX
EXT
P PROJECTOR OUTLET
TELECOMMUNICATIONS MANHOLE.C
COMM
PET PROTECTIVE ENTRANCE TERMINAL
EAS ACS ELECTRICAL OUTLET BOX
P
W
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
-D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
C
AT
EG
O
R Y
C O
D E
1 2 3 4 5
A
M O
O D
Y
AF
B, G
A M
O O
D Y
AF
B
H
AN
G A
R /H
M U
SA
VA
N N
AH
D
IS
TR
IC
T
SA
VA
N N
AH
, G
EO
R
G
IA
AE
C
O M
S
ER
VI
C
E S, IN
C
S J
EF
FE
R
SO
N S
T
ST
E
R
O
AN
O
KE
V A
1-
JU
LY
2, 7 8 9 10
B
C
D
E
F
G
C S
R
1-
5-
W
2H N
-1 9-
R -3
ISSUED FOR CONSTRUCTION
T-001
TE
LE
C O
M M
U N
IC
AT
IO
N
S
LE
G
EN
D A
N D
G
EN
ER
AL
N O
TE
S
AS
T
C
LH
M H
C
M
AR
K D
E
SC
R
IP
TI
O
N D
A
TE
R
EV
IS
ED
IA
W A
M M
EN
D
M
EN
T
7/
/2
SPACE
NETWORK VIDEO RECORDER
(4U) (NIC)
WIRE MANAGER 2U
POE CCTV SWITCH
2 - 48-PORT PATCHPANEL (NIC)
VERTICAL WIRE MANAGER (45U)
VERTICAL PDU
NVR
WIRE MANAGER (NIC)
VMS VIDEO MANAGEMENT SERVER
(2U) (NIC)
LAPTOP INTERFACE CCTV LAPTOP INTERFACE
DRAWER (2U)
SPACE VERTICAL PDU
45 12 PORT FIBER SPLICE /
PATCH PANEL 1U (NIC)
SECURITY
UPS BATTERY
UPS BATTERY
UPS BATTERY
UPS BATTERY
UPS HEAD-END
POE CCTV SWITCH
UPS (NIC)
DATA SWITCH 48 PORT DATA SWITCH, GFGI (NIC)
2 - 48 PORT POE CCTV SWITCHES (NIC)
S1
DATA SWITCH
WIRE MANAGER (2U)
VERTICAL PDU
48-PORT DATA SWITCH, NIC
48-PORT PATCH PANEL (2U)
VERTICAL WIRE MANAGER (45U)
DATA SWITCH
WIRE MANAGER (2U)
48 PORT DATA SWITCH,
NIC
48-PORT PATCH PANEL (2U)
DATA SWITCH
WIRE MANAGER (2U)
48 PORT DATA SWITCH,
NIC
48-PORT PATCH PANEL (2U)
DATA SWITCH
WIRE MANAGER (2U)
48 PORT DATA SWITCH,
NIC
48-PORT PATCH PANEL (2U)
KW VERTICAL PDU
COPPER PATCH PANEL COPPER PATCH PANEL
DATA
TERMINATE
INCOMING
CABLES HERE
3 - 12 PORT FIBER
SPLICE /
PATCH PANEL 1U
(NIC)
T1 AND T2
SPACE
POE VOICE SWITCH
12 PORT FIBER SPLICE /
PATCH PANEL 1U
SECURITY
24-PORT VOICE SWITCH 1U (NIC)
48-PORT PATCH PANEL 2U
POE DATA SWITCH 24-PORT VOICE SWITCH 1U (NIC)
WIRE MANAGER 2U
24-PORT PATCH PANEL 1U
WIRE MANAGER 2U
SPACE
SPACE
SPACE
POWER DISTRIBUTION
NOTE:
THIS ELEVATION IS TYPICAL OF
TWO WALL MOUNTED CABINETS.
1 LOCATED PUMP BUILDING AND 1 LOCATED
IN HANGAR RM 101.
W1 AND W2
SPACE
WIRE MANAGER 2U
24 PORT PATCHPANEL (NIC)
VERTICAL WIRE MANAGER (45U)
VERTICAL PDU
WIRE MANAGER (NIC)
LAPTOP INTERFACE CCTV LAPTOP INTERFACE
DRAWER (2U)
SPACE VERTICAL PDU
45 12 PORT FIBER SPLICE /
PATCH PANEL 1U (NIC)
SECURITY
UPS BATTERY
UPS BATTERY
UPS BATTERY
UPS BATTERY
UPS HEAD-END
POE CCTV SWITCH
UPS (NIC)
39 28 PORT POE CCTV SWITCHES (NIC)
SPACE
SPACE
S2
DATA SWITCH
WIRE MANAGER (2U)
VERTICAL PDU
48-PORT DATA SWITCH, NIC
48-PORT PATCH PANEL (2U)
VERTICAL WIRE MANAGER (45U)
DATA SWITCH
WIRE MANAGER (2U)
48 PORT DATA SWITCH,
NIC
48-PORT PATCH PANEL (2U)
DATA SWITCH
WIRE MANAGER (2U)
48 PORT DATA SWITCH,
NIC
48-PORT PATCH PANEL (2U)
DATA SWITCH
WIRE MANAGER (2U)
48 PORT DATA SWITCH,
NIC
48-PORT PATCH PANEL (2U)
KW VERTICAL PDU
COPPER PATCH PANEL COPPER PATCH PANEL
DATA
TERMINATE
INCOMING
CABLES HERE
2 - 12 PORT FIBER
SPLICE /
PATCH PANEL 1U
(NIC)
T3 AND T4
POWER DISTRIBUTION
WIRELESS MIC RECEIVER(NIC)
T/X INTERFACES(NIC) 4K DGE(NIC)
BLURAY DVD MEDIA PLAYER(NIC)
DIGITAL HD VIDEO PROCESSOR(NIC)
GFE PC WORKSTATION(NIC)
GFE PC WORKSTATION(NIC)
UPS
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
-D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C I T
AT
IO
N N
O
C
AT
EG
O
R Y
C O
D E
1 2 3 4 5
A
M O
O D
Y
AF
B, G
A M
O O
D Y
AF
B
H
AN
G A
R /H
M U
SA
VA
N N
AH
D
IS
TR
IC
T
SA
VA
N N
AH
, G
EO
R
G
IA
AE
C
O M
S
ER
VI
C
E S, IN
C
S J
EF
FE
R
SO
N S
T
ST
E
R
O
AN
O
KE
V A
1-
JU
LY
2, 7 8 9 10
B
C
D
E
F
G
C S
R
1-
5-
W
2H N
-1 9-
R -3
ISSUED FOR CONSTRUCTION
T-201
TE
LE
C O
M M
U N
IC
AT
IO
N
S R
AC
K
EL
EV
AT
IO
N S
AS
T
C
LH
M H
C
NO SCALET-201
1 SECURITY CABINET ELEVATION - RM 136
NO SCALET-201
2 TELECOM CABINET ELEVATION - RM 136
NO SCALET-201
WALL MOUNTED TELECOM CABINET
ELEVATION - PUMP BUILDING & HANGAR RM
NOTE:
THIS ELEVATION TYPICAL OF 2 CABINETS
IN ROOM 136.
NO SCALET-201
4 SECURITY CABINET ELEVATION - RM 217
NO SCALET-201
5 TELECOM CABINET ELEVATION - RM 217
NOTE:
THIS ELEVATION TYPICAL OF 2 CABINETS
IN ROOM 136.
M
AR
K D
E
SC
R
IP
TI
O
N D
A
TE
R
EV
IS
ED
IA
W A
M M
EN
D
M
EN
T
7/
/2
NO SCALET-201
6 AV RACK ELEVATION CONFERENCE ROOM
COMPRESSION TYPE
STEEL CONNECTOR
PULL STRING
SINGLE GANG
PLASTER RING
CAT6 UTP PLENUM
CABLES FOR VOICE
AND DATA
4-PORT SINGLE GANG
FACEPLATE
1" CONDUIT STUBBED-UP
TO ABOVE CEILING
CATV F
CONNECTOR
COXIAL
DATA PORT
RJ45 CAT6
UNCLASSIFIED
NIPRNET
RJ45 CAT 6
(TYP)
FLOOR BOX
BLANK
BLANK
BLANK
DUPLEX
RECEPTACLE
HDMI OUTLETS
PROVIDE FOR AV
CONNECTIVITY ONLY
UNCLASSIFIED
NIPRNET
RJ45 CAT 6
PROVIDE FOR AV
CONNECTIVITY ONLY
GENERAL NOTES THIS SHEET:
A SEE SHEET T-001 FOR LEGEND AND
GENERAL NOTES.
B SEE TY500 SERIES DRAWINGS FOR
ACS/IDS DETAILS.
C SEE TY601 FOR SECURITY SYSTEM
DIAGRAM.
D SEE SHEET E-509 FOR DUCTBANK
DETAILS
HDMI KEYSTONE
OUTLET
P
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
-D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
C
AT
EG
O
R Y
C O
D E
1 2 3 4 5
A
M O
O D
Y
AF
B, G
A M
O O
D Y
AF
B
H
AN
G A
R /H
M U
SA
VA
N N
AH
D
IS
TR
IC
T
SA
VA
N N
AH
, G
EO
R
G
IA
AE
C
O M
S
ER
VI
C
E S, IN
C
S J
EF
FE
R
SO
N S
T
ST
E
R
O
AN
O
KE
V A
1-
JU
LY
2, 7 8 9 10
B
C
D
E
F
G
C S
R
1-
5-
W
2H N
-1 9-
R -3
ISSUED FOR CONSTRUCTION
T-502
TE
LE
C O
M M
U N
IC
AT
IO
N
S D
ET
AI
LS
AS
T
C
LH
M H
C
NO SCALET-502
1 NETWORK OUTLET
NO SCALET-502
2 TYPICAL CATV F CONNECTOR
NO SCALET-502
3 COMBINED FLOOR OUTLET
TV
M
AR
K D
E
SC
R
IP
TI
O
N D
A
TE
R
EV
IS
ED
IA
W A
M M
EN
D
M
EN
T
7/
/2
NO SCALET-502
4 PROJECTOR OUTLET
NOTES:
4 - 4" PVC CONDUIT SCHEDULE 40 ENCASED IN CONCRETE FOR
UTILITY TELEPHONE/COMMUNICATION.
PROVIDE 4FT x 8FT x 3/4" PLYWOOD TELEPHONE BACKBOARD.
BACKBOARD SHALL BE FIRE RETARDANT OR PAINTED WITH A
FIRE RETARDANT PAINT.
ALL FLOOR PENETRATIONS SHALL BE FIRE RATED.
PROVIDE 3 - 4" EMPTY CONDUIT SCHEDULE 40 WITH PULL
ROPE.
25RU WALL MOUNTED CABINET FOR TELECOMMUNICATIONS
AND SECURITY DEVICES HANGAR 101.
1 - 2" EMT CONDUIT WITH 12 STRAND SMFOC. PROVIDE FABRIC
INNERDUCT FOR FUTURE CABLE INSTALLATION.
1.
2.
3.
4.
5.
6.
COMM 136
COMM 217
FIRST FLOOR
SECOND FLOOR
NOTE 3
NOTE 2
NOTE 4
NOTE 1
NOTE 3
NOTE 2
NOTE 5
HANGAR 101
NOTE 6
GENERAL NOTES THIS SHEET:
A SEE SHEET T-001 FOR LEGEND AND
GENERAL NOTES.
B SEE TY500 SERIES DRAWINGS FOR
ACS/IDS DETAILS.
C SEE TY601 FOR SECURITY SYSTEM
DIAGRAM.
D SEE SHEET E-509 FOR DUCTBANK
DETAILS
PAGING CONTROLLER
WITH POWER SUPPLY
NOTE 1
VOICE
SYSTEM
NOTE 1
ZONE 3
HANGAR AREA
ROOM 105
ZONE 2
SECOND FLOOR ADMIN
FA
SYSTEM
NOTE 1
ZONE 1
FIRST FLOOR ADMIN
NOTE 2
NOTES:
1. EQUIPMENT IS NIC.
2. PROVIDE CABLE TIE PER
MANUFACTURER
RECOMMENDATIONS.
3. PROVIDE 1" EMT WITH PULL CORD.
ROOM 136
NOTE 3
TYPICAL
PA
PA PA
PA
PA PA
GROUND
FLOOR
FOPP
GFGI
SWITCH
GFGI
SWITCH
DATA PATCH
PANELS
VOICE PATCH
PANELS
GFCI
CROSS-CONNECT
GFCI
CROSS-CONNECT
GFCI
CROSS-CONNECT
FROM FOPP
DATA
OUTLET
TYP.
VOICE
OUTLET
TYP
CAT6 UTP
CABLE. TYP.
TYPICAL ROOM
PRIMARY LINK 12-STRAND SM
FOC FROM COMM. HUB
CEILING
DATA
CABINET
COMM
ROOM
CAT6 UTP
CABLE. TYP.
FOPP
GFGI
SWITCH
GFGI
SWITCH
DATA PATCH
PANELS
VOICE PATCH
PANELS
GFCI
CROSS-CONNECT
GFCI
CROSS-CONNECT
GFCI
CROSS-CONNECT
FROM FOPP
DATA
OUTLET
TYP.
VOICE
OUTLET
TYP
CAT6 UTP
CABLE. TYP.
TYPICAL ROOM
DATA CABINET
COMM
ROOM
CAT6 UTP
CABLE. TYP.
12-STRAND SMFOC
FOPP
WALL MOUNTED
DATA CABINET
GROUND
FLOOR
BUILDING
PROTECTOR
ENTRANCE
TERMINAL
BACKBONE
VOICE PATCH
PANEL
ANALOG
VOICE
OUTLET
NOTE:
1. FOR EACH BACKBONE CABLE, TERMINATE 1-PAIR ON EACH PATCH PANEL PORT
2. FOR HORIZONTAL CABLES, TERMINATE 4-PAIRS ON EACH PATCH PANEL PORT.
COMM ROOM 136
AND PUMP BUILDING
(1) 25PR OSP COPPER
CABLE FROM SITE
DISTRIBUTION
CEILING
ANALOG
VOICE PATCH
PANEL
CAT6 UTP CABLE, TYP.
25PR-PR CAT3 UTP
BACKBONE TIE CABLE
GFGI CROSS-CONNECT
VOICE CABINET
TYPICAL ROOM
3. GOVERNMENT TO IDENTIFY ANALOG VOICE OUTLET LOCATIONS.
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
-D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
I O
N N
O
C
AT
EG
O
R Y
C O
D E
1 2 3 4 5
A
M O
O D
Y
AF
B, G
A M
O O
D Y
AF
B
H
AN
G A
R /H
M U
SA
VA
N N
AH
D
IS
TR
IC
T
SA
VA
N N
AH
, G
EO
R
G
IA
AE
C
O M
S
ER
VI
C
E S, IN
C
S J
EF
FE
R
SO
N S
T
ST
E
R
O
AN
O
KE
V A
1-
JU
LY
2, 7 8 9 10
B
C
D
E
F
G
C S
R
1-
5-
W
2H N
-1 9-
R -3
ISSUED FOR CONSTRUCTION
T-602
TE
LE
C O
M M
U N
IC
AT
IO
N
S D
IA
G
R
AM
S
AS
T
C
LH
M H
C
NO SCALET-602
TELECOMMUNICATIONS RACEWAY RISER
DIAGRAM - HANGAR
NO SCALET-602
2 PA SYSTEM DIAGRAM
NO SCALET-602
TELECOMMUNICATIONS VOICE AND DATA
CABLING RISER DIAGRAM
NO SCALET-602
TELCOMMUNICATIONS ANALOG VOICE RISER
CABLING DIAGRAM
M
AR
K D
E
SC
R
IP
TI
O
N D
A
TE
R
EV
IS
ED
IA
W A
M M
EN
D
M
EN
T
7/
/2
| P-502 DETAILS |
| T-001 TELECOMMUNICATIONS LEGEND AND GENERAL NOTES |
| T-201 TELECOMMUNICATIONS RACK ELEVATIONS |
| T-502 TELECOMMUNICATIONS DETAILS |
| T-602 TELECOMMUNICATIONS DIAGRAMS |