W912HN-20-B-3002_VOL1_AMD3.PDF
PDF 16 MB Posted
- Solicitation number
- W912HN20B3002
About this file
This solicitation posting is for the Moody AFB Personnel Recovery Hanger project through the Department of the Army Corps of Engineers Engineering District Savannah. The solicitation number is W912HN20B3002 and was posted on June 23, 2020. It is a full and open unrestricted competition seeking bids for specifications files and plans/drawings files related to the construction of the Moody AFB Personnel Recovery Hanger. Bids for the project are due by June 23, 2020 at 2:00pm Eastern Time. The solicitation provides relevant project details and specifications to support competitive bidding from contractors for the construction of the Moody AFB Personnel Recovery Hanger.
View the file
Other files
Show all 35
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
B
A
M E
N D
M E
N T
D
W G
H M
A
B S
A
S K
W
G F
O
S O
I L
C
L A
S S
I F
I C
A T
I O
O T
E S
O
I L
T
E S
T
B
O R
I N
G
L O
G S
BB610
S O
L I C
I T
A T
I O
N
N
O
D E
S I G
N E
D
B
Y
D E
S C
R I P
T I O
N
A
M A
R K
S I Z
E
S U
B M
I T
T E
D
B
Y
D A
T E
C O
N T
R A
C
C H
E C
K E
D
B
Y
D R
A W
N
B
Y
I S
S U
E
D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
M O
O D
Y
A
F B
G
A
M O
O D
Y
A
F
H
A N
G A
R H
M U
SHEET ID
W
H N
R
A N
S I D
J U
L Y
U
R M
Y
C
O R
P
E
N G
I N
E E
R S
S A
V A
N N
D
I S
T R
I C
T
S A
V A
N N
A H
G
E O
R G
I A
A E
C O
M
S
E R
V I C
E S
I N
C
J
F F
E R
S O
N
S
T
S
R O
A N
O K
E
V
A
US Army Corps of Engineers ®
C A
T A
G O
D
E
F I L
E
N
A M
E
ISSUED FOR CONSTRUCTION
A M
E N
D M
E N
T
Know what's below.
Call before you dig
SOIL TEST BORING LOGS,
SOIL CLASSIFICATION & NOTES 9
N.T.S.
/2
7/
/2 7/
WV
FH
"STOP"
LP
MH
"STOP"
4'x4' CONC. PAD
CO
MH
S I J A
N
S
T
"STOP"
"STOP"
BUILDING B
A S
P H
A
V
I N
G
ASPHALT PAVING
A S
P H
A
V
I N
G
SSMH
TOP: 227.49
SSMH
TOP: 228.94
5'x5' CONC. PAD
BL
ASPHALT PAVING
C O
N C
S
I D
E W
A L K
WV
ASPHALT PAVING
COMM MH
EXISTING CHAINLINK
SECURITY FENCE
PIV
D
SANITARY MANHOLE
NORTH RIM: 228.14'
INV A: 219.71'
INV B: 219.74'
INV C: 220.33'
INV D: 219.65'
S
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
D
G
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C
C
C
C
C
PI
V
PI
V
E
E
S
S
S
D
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C O
M
M
C O
M M
E
D
D
C
O
M
M
C
O
M
M
C
O
M
M
H
Y D
E
S
I
J
EXISTING
UTILITY
CORRIDOR
WV
WV
WV
WV
FH
FH
GM
WV
FH
WV
A S
P H
A
V
I N
G
CONCRETE PAVEMENT
CONCRETE PAVEMENT
ASPHALT PAVING
"STOP"
WV
WV
WV
BL
C
O
N
D
E
W
A
L
K
SANITARY SEWER MH
NORTH RIM: 227.34'
INV A: 217.93'
INV B: 217.87'
SANITARY SEWER MH
NORTH RIM: 226.09'
INV A: 217.14'
INV A DROP: 213.62'
INV B: 213.60'
A
B
A
B
FH
TANK 2
C O
N C
R E
V
E M
E N
T
C O
N C
R E
V
E M
E N
T
C O
N C
R E
V
E M
E N
T
CONCRETE PAVEMENT
A S
P H
A
V
I N
G
CONC. SIDEWALK
F E
N C
E
BL
BL
BL
BL
BL
BL
BL
BL
BL
BL
BL
BL
LP
BL BL
BL
BL
UR
P
P
P
E X
I S
T I N
G
C
H A
I N
L I N
K
S
E C
U R
I T
Y
F
E N
C E
SANITARY MANHOLE
TOP: 226.06'
INV IN: 219.38'
INV OUT: 216.88'
25' BUFFER
ASPHALT PAVING
PROJECT BASE POINT
E: 358787.0675
N: 2598654.7205
S
S
MH
226.78
226.86
224.24
223.68
223.90
JB
TOP: 227.58
DI
TOP: 227.76
24" RCP INV OUT=222.26
E
X
I
S
T
I
G
M
I
N
E X
I S
T I N
G
F
I R
E
M
A I N
E X
I S
T I N
G
F
I R
E
M
A I N
E X
I S
T I N
G
W
A T
I N
E X
I S
T I N
G
S
A N
I T
A R
Y
S
E W
P
I N
G
E X
I S
T I N
G
U
G
T
E L E
C O
C
T B
A N
K
E X
I S
T I N
G
N
A T
U R
A L
G
P
I N
G
JB
TOP: 226.75
JB
TOP: 227.20
C
O
N
C
F
L
U
M
E
?" RCP
R
C P
R
C P
P
P
JB
TOP: 228.39
24" RCP INV IN=219.89
24" RCP INV OUT=219.87
JB
TOP: 227.58
42" RCP INV IN=218.78
42" RCP INV OUT=218.74
DI
TOP: 224.94
8" PVC INV IN=223.39
18" RCP INV IN=219.24
DI
TOP: 226.35
18" RCP INV IN=221.05
36" RCP INV IN=219.91
36" RCP INV OUT=219.65
DI
TOP: 225.55
36" RCP INV IN=218.63
42" RCP INV OUT=218.37
DI
TOP: 227.06
36" RCP INV IN=220.84
36" RCP INV OUT=220.58
HEADWALL
48" RCP INV=215.81
DI
TOP: 222.63
15" RCP INV IN=218.5
15" RCP INV IN=217.14
48" RCP INV IN=217.08
48" RCP INV OUT=216.53
DI
TOP: 220.10
15" RCP INV OUT=217.86
JB
TOP: 223.35
48" RCP INV IN=216.93
48" RCP INV OUT=216.89
15" RCP INV IN=220.23
24" RCP INV IN=219.15
36" RCP INV IN=218.71
42" RCP INV OUT=218.36
DI
TOP: 225.78
42" RCP INV IN=218.21
48" RCP INV OUT=218.18
JB
TOP: 226.11
15" RCP INV IN=217.63
48" RCP INV IN=217.16
48" RCP INV OUT=217.19
DI
TOP: 223.61
15" RCP INV IN=220.15
TRENCH DRAIN
TOP: 223.65
15" RCP INV OUT=219.37
A
S
P
H
A
V
I
N
G
A
S
P
H
A
V
I
N
G
EXTENT OF DEMOLITION
EXTENT OF DEMOLITION
EXTENT OF DEMOLITION
EXTENT OF DEMOLITION
EXTENT OF DEMOLITION
L I M
I
N
S T
R U
C T
I O
N
LIMITS OF CONSTRUCTION
L I M
I
N
S T
R U
C T
I O
N
LIMITS OF CONSTRUCTION
L I M
I
N
S T
R U
C T
I O
N
L I M
I
N
S T
R U
C T
I O
N
BUILDING 655
LP
EXIST. LIGHT
CONTROLS
EXIST. HIGH
MAST LIGHT POLE
EXIST. LIGHT
CONTROLS
EXIST. HIGH
MAST LIGHT POLE
W
E
T
L
A
N
D
S
W
E
T
L
A
N
D
S
TANK 1
B
L
G
S
I
J
F
F
E
R
BUILDING 645
(TO REMAIN)
AIRCRAFT PARTS STORE
HC-130/HH-60
S O
L I C
I T
A T
I O
N
N
O
D E
S I G
N E
D
B
Y
D E
S C
R I P
T I O
N
A
M A
R K
S I Z
E
S U
B M
I T
T E
D
B
Y
D A
T E
C O
N T
R A
C H
E C
K E
D
B
Y
D R
A W
N
B
Y
I S
S U
E
D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
M O
O D
Y
A
F B
G
A
M O
O D
Y
A
N
G A
R H
M U
SHEET ID
W
H N
R
A N
S I D
J U
M
Y
C
O R
E
N G
I N
E E
R S
S A
V A
N N
S
T R
I C
T
S A
V A
N N
A H
G
E O
R G
I A
A E
C O
M
S
E R
V I C
E S
I N
C
F F
E R
S O
N
S
T
S
R O
A N
O K
E
V
A
US Army Corps of Engineers ®
C A
T A
G O
D
E
F I L
E
N
A M
E
ISSUED FOR CONSTRUCTION
A M
E N
D M
E N
T
C D
A
M E
N D
M E
D
W G
H M
A
B S
A
S K
W
G F
O
D E
M O
L I T
I O
N
P
L A
N
CD101
W
WFH,
CPP
EMH
EM
LP,
CONTROL POINT
FFE
PVC
GV,
G
COMM
AC,
WV,
SIGN
PP,
GP,
CB
DI
JB
PIV,
DEMOLITION FOR
PAVEMENT, STRUCTURE,
OR BUILDING
SPOT ELEVATION
FINISHED FLOOR ELEVATION
CHAIN LINK FENCE
GAS LINE
WATER LINE
POST INDICATOR VALVE
FIRE HYDRANT
WATER VALVE
GAS VALVE
CORRUGATED PLASTIC PIPE
POLYVINYL CHLORIDE PIPE
JUNCTION BOX
CATCH BASIN
DROP INLET
AIR CONDITIONER
ELECTRIC MANHOLE
ELECTRIC METER
UG COMMUNICATIONS
GUY POLE
POWER POLE
LIGHT POLE
EXISTING CONCRETE
EXISTING ASPHALT
Know what's below.
Call before you dig
WETLANDS DELINEATION
BOUNDARY
MATCHLINE
SEE SHEET CD102
LIMITS-OF-CONSTRUCTION
30 0 30 60 90
GRAPHIC SCALE: 1 INCH = 30 FEET
DEMOLITION PLAN 1
SCALE: 1" = 30'
N O
R T
H
G E
O R
G
W
S
T
Z
O N
E
N A
D
DRAINAGE AND DEWATERING NOTE
ALL EXCAVATIONS SHALL BE PERFORMED SO THAT THE SITE AND AREA
IMMEDIATELY SURROUNDING THE SITE WHICH AFFECTS CONSTRUCTION
OPERATIONS WILL BE CONTINUALLY AND EFFECTIVELY DRAINED. THE
CONTRACTOR SHALL PROVIDE DRAINAGE AND DEWATERING AS REQUIRED TO
ENSURE THAT ALL FOOTING EXCAVATIONS ARE ACCOMPLISHED WITH THE
SUBGRADE SOILS REMAINING DRY AND FIRM UNTIL AFTER FOOTINGS ARE
PLACED AND BACKFILLED. REMOVAL OF SURFACE WATER, GROUNDWATER,
AND ANY PERCHED-WATER CONDITIONS, WHICH MIGHT BE ENCOUNTERED
DURING EXCAVATIONS SHALL BE ACCOMPLISHED BY APPROVED MEANS.
REFER TO SPECIFICATION 31 00 00 EARTHWORK FOR ADDITIONAL
REQUIREMENTS.
DEMOLITION NOTES
1. CONTRACTOR SHALL CONDUCT DEMOLITION ACTIVITIES WITHOUT
INTERFERING WITH VEHICLE AND PEDESTRIAN TRAFFIC IN ADJACENT
AREAS.
2. INITIAL EROSION CONTROL SHALL BE INSTALLED PRIOR TO AND
CONCURRENTLY WITH SITE DEMOLITION.
3. CONTRACTOR SHALL PROTECT UTILITIES NOT SCHEDULED FOR
DEMOLITION FROM DAMAGE. AT NO ADDITIONAL COST TO THE OWNER,
THE CONTRACTOR SHALL REPLACE OR REPAIR ITEMS DAMAGED
BEYOND THE LIMITS OF DEMOLITION SHOWN.
4. REMOVE EXISTING ABOVE/BELOW GRADE DEMOLITION AS INDICATED
TO BE REMOVED, TO THE LIMIT INDICATED.
5. CONTRACTOR TO REMOVE ALL DEBRIS, RUBBISH AND WASTE
MATERIALS FROM THE SITE. DO NOT STOCKPILE DEBRIS ON SITE. ALL
MATERIALS TO DISPOSED IN A LEGAL MANNER.
6. DEMOLITION OF THE EXISTING PUMP HOUSE, BLDG 652, AND BLDG 655
WILL CONSIST OF REMOVAL OF WALLS, ROOF, FOUNDATION AND ANY
WIRING, CONDUIT AND PIPING ASSOCIATED WITH THE BUILDING. THE
EXTERNAL WATER TANKS ARE ALSO TO BE REMOVED ALONG WITH ANY
FOUNDATION ASSOCIATED WITH THEM.
7. THE EXISTING 12" FIRE MAIN WHICH RUNS ALONG SIJAN ST. AND THE
FRONT SIDE OF THE EXISTING PUMP HOUSE, BLDG 652, (AND, TURNING
NORTH, TO THE WEST SIDE OVERHANG AREA OF REMAINING BLDG 645)
WILL BE REMOVED SOUTH OF THE PUMP HOUSE WHERE THE
DEMOLITION HATCH PATTERN STARTS AT BOTTOM OF SHEET CD102
(APPROX. 250 FT. FROM PUMP HOUSE) AND WILL BE REMOVED UP TO
THE WEST SIDE OVERHANG AREA OF REMAINING BLDG 645. THE
APPROXIMATE LENGTH OF 12" PIPE TO REMOVE IS 525 LF. BOTH
REMAINING CUT ENDS OF THIS PIPE WILL BE CAPPED UNTIL A PIPE
BYPASS IS INSTALLED DURING CONSTRUCTION - SEE CIVIL UTILITIES
PLANS CU201 AND CU202 FOR MORE INFORMATION. ANY VALVES OR
OTHER DEVICES ASSOCIATED WITH THE REMOVED SECTION OF THIS
PIPE IS ALSO TO BE REMOVED.
8. ALL WIRING, CONDUIT AND PIPING THAT RUN ALONG SIJAN ST. AND ARE
WITHIN THE DEMOLITION HATCHING ON SHEETS CD101 AND CD102 IS
TO BE REMOVED ALONG WITH ASSOCIATED ABOVE-GROUND
EQUIPMENT AND CONCRETE PADS AND UNDERGROUND ACCESS AREAS
(MANHOLES).
9. ALL UNDERGROUND UTILITIES THAT RUN ALONG SIJAN ST. AND ARE
SHOWN TO BE REMOVED ON SHEETS CD101 AND CD102 ARE TO BE
REMOVED ALONG WITH ANY ASSOCIATED ABOVE-GROUND EQUIPMENT
AND CONCRETE PADS. ALL UTILITIES SHALL BE TERMINATED AT THE
NEAREST MANHOLE OR JUNCTION NOT SHOWN TO BE REMOVED.
EXISTING STORMWATER PIPING
DEMOLITION NOTES (continued)
15. DISCONNECT AND SEAL OFF ABANDONED UTILITIES AND UTILITIES TO
BE REMOVED PRIOR TO THE START OF ANY OTHER DEMOLITION
ACTIVITIES. UTILITIES SHALL BE DISCONNECTED BELOW EXISTING
GRADE LEVEL, OR OUTSIDE OF CONTRACT LIMITS BY
REPRESENTATIVES OF THE PUBLIC UTILITY BEING DISCONNECTED.
MAINTAIN UTILITY SERVICE TO FACILITIES IN USE.
16. CONTRACTOR SHALL OBTAIN ANY PERMITS REQUIRED BY THE DEPT.
OF DEFENSE AND/OR LOWNDES COUNTY AND SHALL BE POSTED
ON-SITE AT ALL TIMES DURING DEMOLITION WORK OR ANY LAND
DISTURBING ACTIVITIES.
17. EXISTING APRON LIGHTING TO BE RELOCATED. RETAIN AND
PROTECT EXISTING WIRING DURING DEMOLITION.
LEGEND
UTILITIES TO BE DEMOLISHED
REMOVE AND
REPLACE STORM
STRUCTURE AND PLUG
REMAINING 15" PIPE.
SEE DRAINAGE PLAN.
REMOVE EXISTING GRATE
AND FRAME. DRAINAGE
STRUCTURE TO BE
MODIFIED AS SHOWN ON
DRAINAGE PLAN.
REMOVE EXISTING GRATE
AND FRAME. DRAINAGE
STRUCTURE TO BE
MODIFIED AS SHOWN ON
DRAINAGE PLAN.
SAW CUT AND REMOVE CONCRETE TO
FACILITATE PROPOSED CONSTRUCTION
AROUND HYDRAULIC TRUCK LOADING DOCK
AND IN CONJUNCTION w/ NEW PAVEMENT.
THIS PORTION OF
LOADING DOCK
TO REMAIN.
OVERALL DEMOLITION BNDY
G G
EXISTING BUILDING
DEMOLITION NOTES (continued)
10. UTILITIES RUNNING PARALLEL TO AND CROSS SIJAN ST. TO THE NORTH
OF THE EXISTING PUMP HOUSE ARE TO REMAIN. THEY ARE THE
EXISTING BYPASS, CALLED THE 'EXISTING UTILITIES CORRIDOR'. THEY
PASS SOUTH AND TO THE WEST OF THIS CONSTRUCTION. THEY WILL
BE UTILIZED AS NEEDED FOR THIS CONSTRUCTION - SEE CIVIL SHEETS
CU201 AND CU202 FOR MORE INFORMATION.
11. EXCEPT WHERE SHOWN ON THIS SHEET, ALL EXISTING STORMWATER
PIPING TO REMAIN ALONG WITH ASSOCIATED MANHOLES AND WILL BE
UTILIZED FOR STORMWATER MANAGEMENT. SEE CIVIL SHEETS CG103
AND CG104 FOR MORE INFORMATION.
12. EXISTING SECURITY FENCING TO BE DEMOLISHED FROM THE
SOUTHEAST CORNER OF BLDG 645 TO LIMIT OF CONSTRUCTION
BOUNDARY ON CIVIL SHEET CD102.
13. REMOVE CONCRETE SIDEWALK THAT RUNS ALONGSIDE SIJAN ST. THE
SAME DISTANCE AS THE SIJAN ST. DEMOLITION.
EXISTING WETLANDS
LI
C
IT
A
TI
O
N N
O
D E
S
IG
N E
D B
Y
A
S
IZ
E
S U
B M
IT
TE
D B
Y
C O
N
TR
A C
T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E
D A
TE
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
M O
O D
Y A
FB
, G
A M
O O
D Y
A
FB
H A
N G
A R
/H M
U
SHEET ID
W
2H N
-1 9-
R -3
A N
S I-D
JU
LY
2, U
S A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
S A
V A
N N
A H
D
IS
TR
IC
T S
A V
A N
N A
H , G
E O
R G
IA
A E
C O
M S
E R
V
IC
E S
, I N
C
S
J E
FF
E
R S
O N
S T
S
TE
R
O A
N O
K E
V A
-1
US Army Corps of Engineers ®
C A
TA
G
O R
Y C
O D
E
1-
5-
FI
LE
N
A M
E
ISSUED FOR CONSTRUCTION
C
S
3.
D
W G
H M
A
B S
A
S K
W
G
FO
S
IT
E D
E
TA
IL
S
CS503
Z:\18-0047 Moody AFB\DWG\Sheets\Sheet Files\23 CS503.dwg, 8/2/2019 2:25:26 PM
W
2H N
-2 0-
B-
W
2H
N -2
0- B-
1' -0
2"R
1"
1- 1/
2" 6"
SLOPE: 1"/FT
5"
24" CONCRETE CURB & GUTTER
NOT TO SCALE
1'-0" 6" 1'-6"
EXPANSION JOINTS REQUIRED AT
ALL STRUCTURES AND CURB
RETURNS. MAX. DIST BETWEEN
CONTROL JOINTS - 25 FT.
3000 P.S.I. HIGH EARLY STRENGTH
CONCRETE, 2" SLUMP, W/ SMOOTH
FINISH.
CONTRACTOR TO SLOPE
GUTTER AS APPROPRIATE.
GRADED AGGREGATE
BASE SEE PAVING
DETAILCOMPACT SUBGRADE TO 98%
STANDARD PROCTOR.
M6F0.1P2
REFER TO GDOT STD. A3
SIDEWALK DETAILS
REFER TO GDOT STD. D-10
CONCRETE SWALE DETAIL
(4'-0" MAX. HEIGHT x 20 LF)
#4 BAR VERTICAL
REINFORCEMENT
SPACED 8" O.C.
8" CMU RETAINING WALL
CONC.
SIDEWALK ABOVE
8"CMU
WALL
M
A X
H
E I G
H T
S E
E
L
A P
S P
L I C
E
C
H A
R T
C
O V
E R
R E
Q D
8"
32"
2" CLR.
8-INCH CONCRETE
MASONRY UNIT WALL -
FILL ALL CELLS WITH
3,000 PSI CONCRETE
LAP SPLICE CHART
BAR
SIZE
LAP
SPLICE (IN)
4 29
5 36
6 43
7 48
8 72
9 80
10 102
DESIGN CRITERIA
1. CONCRETE TO BE 3,000 P.S.I. (MIN).
2. REINFORCING TO BE GRADE 60.
3. MINIMUM ALLOWABLE SOIL BEARING PRESSURE TO BE
2,500 P.S.F.
4. LATERAL EQUIVALENT FLUID DESIGN PRESSURE: 35.0
P.S.F.
5. BACKFILL MATERIAL TO BE AS SHOWN.
6. SURCHARGE LOADING: NONE.
GENERAL NOTES
1. ALL REINFORCING STEEL TO BE SET IN ACCORDANCE
WITH CURRENT ACI CODE 318 (2" CLR. TO NEAREST WALL
FACE AND 3" CLR. TO EARTH IN FOOTING).
2. LAP ALL SPLICES IN ACCORDANCE WITH ACI CODE 318
(SEE LAP SPLICE CHART).
3. COMPACT BACKFILL TO 95% OF STANDARD PROCTOR.
USE ONLY SMALL HAND-HELD EQUIPMENT NEAR WALL.
4. THIS DRAWING IS SPECIFICALLY DESIGNED AND
INTENDED FOR THIS SITE ONLY AND IS NOT VALID FOR
ANY OTHER SITE.
PAVEMENT
BELOW
HANDRAIL
#4 REBAR GRID
12" O.C./E.W.
#4 BENT DOWELS
@ 8" O.C.
CONC.
FOOTING
NOT TO SCALE
NOT TO SCALE
D E
S C
R I P
T I O
N M
A R
K D
A T
E
A
M E
N D
M E
D E
S C
R I P
T I O
N M
A R
K D
A T
E
A
M E
N D
M E
D E
S C
R I P
T I O
N M
A R
K D
A T
E
A
M E
N D
M E
/1 7/
/2
7/
A
M E
N D
M E
N T
3 2
A M
E N
D M
E N
T
REFER TO SHEET C-301
HEAVY-DUTY PAVEMENT DETAIL
4'x4' CONC. PAD
S I J A
N
S
T
BUILDING 645
(TO REMAIN)
AIRCRAFT PARTS STORE
HC-130/HH-60
BUILDING B
A S
P H
A
V
I N
G
ASPHALT PAVING
A S
P H
A
V
I N
G
OVERHANG
AREA
GATE
5'x5' CONC. PAD
BL
ASPHALT PAVING
C O
N C
S
I D
E W
A L K
ASPHALT PAVING
EXISTING CHAINLINK
SECURITY FENCE
D
D
D
C O
N C
R E
V
E M
E N
T
C O
N C
R E
V
E M
E N
T
C O
N C
R E
V
E M
E N
T
CONCRETE PAVEMENT
A S
P H
A
V
I N
G
CONC. SIDEWALK
F E
N C
E
BL
BL
BL
BL
BL
BL
BL
BL
BL
BL
BL
BL
L
C
ASPHALT PAVING
MH
PROJECT BASE POINT
E: 358787.0675
N: 2598654.7205
228.00
227.85
227.95
227.35
228.00
228.00
227.75
227.75
227.75
227.40
227.75
TW: 227.75
BW: 224.25
227.75
227.85
227.85
225.15
225.05
226.20
226.20
226.80
???226.35
MH
MH
M H
L I M
I
N
S T
R U
C T
I O
N
LIMITS OF CONSTRUCTION
L I M
I
N
S T
R U
C T
I O
N
LIMITS OF CONSTRUCTION
L I M
I
N
S T
R U
C T
I O
N
L I M
I
N
S T
R U
C T
I O
N
3.0'
(TYP.)
TW: 226.40
BW: 225.00
227.75
226.30
227.05
228.00
228.00
228.00
227.95
227.85
227.85
TOP OF
POND
BERM
PROP. FIRE
WATER TANK
BLDG 677
PUMPHOUSE
FFE: 228.00
(SEE ARCH.
PLANS)
BUILDING 675
PROPOSED HELICOPTER
MAINTENANCE UNIT
FFE = 228.25
(SEE ARCH. PLANS)
EXISTING GRASSED AREA
PROPOSED GRASSED AREA
EXISTING GRASSED AREA
EXISTING GRASSED AREA
EXISTING GRASSED AREA
EXISTING GRASSED AREA
PROPOSED CONC. HANGAR
ACCESS APRON WEST
(SEE SHEET C-301, DET. 4)
PROPOSED
GRASSED AREA
PROPOSED CONC. HANGAR
ACCESS APRON EAST
(SEE SHEET C-301, DET. 4)
20.00'
C G
A
M E
N D
M E
D
W G
H M
A
B S
A
S K
W
G F
O
S I T
E
G
R A
D I N
G
P
L A
N
CG101
S O
L I C
I T
A T
I O
N
N
O
D E
S I G
N E
D
B
Y
A
S I Z
E
S U
B M
I T
T E
D
B
Y
C O
N T
R A
C H
E C
K E
D
B
Y
D R
A W
N
B
Y
I S
S U
E
D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
M O
O D
Y
A
F B
G
A
M O
O D
Y
A
N
G A
R H
M U
SHEET ID
W
H N
R
A N
S I D
J U
M
Y
C
O R
E
N G
I N
E E
R S
S A
V A
N N
S
T R
I C
T
S A
V A
N N
A H
G
E O
R G
I A
A E
C O
M
S
E R
V I C
E S
I N
C
F F
E R
S O
N
S
T
S
R O
A N
O K
E
V
A
US Army Corps of Engineers ®
C A
T A
G O
D
E
F I L
E
N
A M
E
ISSUED FOR CONSTRUCTION
MATCHLINE
SEE SHEET CG102
CPP
CONTROL POINT
FFE
SIGN
CB
DI
JB
SPOT ELEVATION
FINISHED FLOOR ELEVATION
EXISTING CHAIN LINK FENCE
CORRUGATED PLASTIC PIPE
JUNCTION BOX
CATCH BASIN
DROP INLET
LIMITS OF CONSTRUCTION
30 0 30 60 90
GRAPHIC SCALE: 1 INCH = 30 FEET
SITE GRADING PLAN 1
SCALE: 1" = 30'
N O
R T
H
G E
O R
G
W
S
T
Z
O N
E
N A
D
STORMWATER
MGMT AREA
LEGEND
SITE GRADING NOTES
1. CONTRACTOR TO TAKE ALL PRECAUTIONS TO FIND AND AVOID SITE
UTILITIES. ALL UTILITIES MAY NOT BE SHOWN ON DRAWINGS.
2. CONTRACTOR TO COORDINATE WITH ALL UTILITY COMPANIES PRIOR
TO BEGINNING GRADING ACTIVITIES.
3. EROSION CONTROL MATTING SHALL BE INSTALLED ON ALL SLOPES
GREATER THAN 3:1.
4. CONTRACTOR SHALL NOTIFY A COE CONTRACTING OFFICER OR
REPRESENTATIVE WITHIN 24 HOURS OF ANY LAYOUT DISCREPANCY
PRIOR TO PROCEEDING WITH WORK. ALL ADDITIONAL COSTS,
INCLUDING BUT NOT LIMITED TO REMEDIAL CONSTRUCTION,
ADDITIONAL SITE VISITS, OR ENGINEERING SERVICES AND FEES, ETC.
INCURRED DUE TO FAILURE TO FOLLOW THIS PROCEDURE WILL BE
THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
SITE GRADING NOTES
5. DRAINAGE AND DEWATERING:
ALL EXCAVATIONS SHALL BE PERFORMED SO THAT THE SITE AND
AREA IMMEDIATELYSURROUNDING THE SITE WHICH AFFECTS
CONSTRUCTION OPERATIONS WILL BE CONTINUALLY AND
EFFECTIVELY DRAINED. THE CONTRACTOR SHALL PROVIDE DRAINAGE
AND DEWATERING AS REQUIRED TO ENSURE THAT ALL FOOTING
EXCAVATIONS ARE ACCOMPLISHED WITH THE SUBGRADE SOILS
REMAINING DRY AND FIRM UNTIL AFTER FOOTINGS ARE PLACED AND
BACKFILLED. REMOVAL OF SURFACE WATER, GROUNDWATER, AND
ANY PERCHED-WATER CONDITIONS, WHICH MIGHT BE ENCOUNTERED
DURING EXCAVATIONS SHALL BE ACCOMPLISHED BY USING
APPROVED METHODS BY ENGINEER. REFER TO SPECIFICATION 31 00
00 EARTHWORK FOR ADDITIONAL REQUIREMENTS.
STRUCTURE NOTES
UTILITY STRUCTURES CAN BE PRE-CAST AND INCLUDE BUT ARE NOT LIMITED
TO INLETS, MANHOLES, JUNCTION BOXES, HANDHOLES AND CLEANOUTS
CONSTRUCTED IN RUNWAYS, TAXIWAYS, TOWWAYS, HELIPADS, APRONS,
OVERRUNS, SHOULDERS (PAVED AND UNPAVED) SHALL BE DESIGNED AND
LOAD-RATED WITH THE FOLLOWING REQUIREMENTS:
LOAD-BEARING PAVEMENTS AND PAVED SHOULDER AREAS:
1. FOR MANHOLE COVERS AND INLET GRATES AND FRAMES, DESIGN FOR
A 100,000 LB AT WHEEL LOAD WITH 250 PSI TIRE PRESSURE. INLET
GRATES, COVERS, FRAMES AND LIDS OF UTILITY STRUCTURES SHALL BE
BOLT-DOWN, HEAVY-DUTY AIRFIELD TYPE CASTINGS.
2. FOR STRUCTURES WITH THEIR SHORTEST SPAN EQUAL TO OR LESS
THAN 2 FT, DESIGN BASED ON A SINGLE WHEEL LOAD OF 100,000LB AT A
CONTACT PRESSURE OF 250 PSI, OR A UNIFORM LIVE LOAD OVER THE
ENTIRE STRUCTURE OF 250 PSI, WHICHEVER IS GREATER.
3. FOR STRUCTURES WITH THEIR SHORTEST SPAN GREATER THAN 2 FT,
DESIGN BASED ON THE MAXIMUM NUMBER OF WHEELS THAT CAN FIT
ONTO THE SPAN, CONSIDERING THE MOST CRITICAL ASSIGNED
AIRCRAFT OPERATING AT ITS MAXIMUM GROSS WEIGHT. IN NO CASE,
HOWEVER, SHOULD THE DESIGN BE BASED ON COMPUTED STRESS
CONDITIONS LESS THAN THOSE CREATED BY A WHEEL LOAD OF 100,000
LB AT A CONTACT PRESSURE OF 250 PSI.
UNPAVED SHOULDER AREAS:
1. FOR MANHOLE COVERS AND INLET GRATES AND FRAMES, DESIGN FOR
A 100,000 LB WHEEL LOAD WITH 250 PSI TIRE PRESSURE. INLET
GRATES, COVERS, FRAMES AND LIDS OF UTILITY STRUCTURES SHALL
BE BOLT-DOWN, HEAVY-DUTY AIRFIELD TYPE CASTING.
2. FOR STRUCTURES WITH THEIR SHORTEST SPAN EQUAL TO OR LESS
THAN 2 FT, DESIGN BASED ON A SINGLE WHEEL LOAD OF 50,000 LB AT A
CONTACT PRESSURE OF 250 PSI, OR A UNIFORM LIVE LOAD OVER THE
ENTIRE STRUCTURE OF 250 PSI, WHICHEVER IS GREATER.
3. FOR STRUCTURES WITH THEIR SHORTEST SPAN GREATER THAN 2 FT,
DESIGN BASED ON THE MAXIMUM NUMBER OF WHEELS THAT CAN FIT
ONTO THE SPAN, CONSIDERING THE MOST CRITICAL ASSIGNED
AIRCRAFT OPERATING AT ITS MAXIMUM GROSS WEIGHT. IN NO CASE,
HOWEVER, SHOULD THE DESIGN BE BASED ON COMPUTED STRESS
CONDITIONS LESS THAN THOSE CREATED BY A WHEEL LOAD OF 50,000
LB AT A CONTACT PRESSURE OF 250 PSI.
OTHER AIRFIELD AREAS:
4. BEYOND THE PAVED OR UNPAVED SHOULDER AREAS OF RUNWAYS,
TAXIWAYS, TOWWAYS, HELIPADS, APRONS OR OVERRUNS,
UNDERGROUND STRUCTURES ARE NOT DESIGNED TO SUPPORT
AIRCRAFT WHEEL LOADS; HOWEVER, THEY WILL BE DESIGNED TO
SUPPORT STANDARD TRUCK LOADS (AASHTO H20/HS20).
Know what's below.
Call before you dig
S O
L I C
I T
A T
I O
N
N
O
D E
S I G
N E
D
B
Y
A
S I Z
E
S U
B M
I T
T E
D
B
Y
C O
N T
R A
C H
E C
K E
D
B
Y
D R
A W
N
B
Y
I S
S U
E
D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
M O
O D
Y
A
F B
G
A
M O
O D
Y
A
N
G A
R H
M U
SHEET ID
W
H N
R
A N
S I D
J U
M
Y
C
O R
E
N G
I N
E E
R S
S A
V A
N N
S
T R
I C
T
S A
V A
N N
A H
G
E O
R G
I A
A E
C O
M
S
E R
V I C
E S
I N
C
F F
E R
S O
N
S
T
S
R O
A N
O K
E
V
A
US Army Corps of Engineers ®
C A
T A
G O
D
E
F I L
E
N
A M
E
ISSUED FOR CONSTRUCTION
DITCH C/L
MIN. 1% DRAINAGE w/
3:1 SIDE SLOPES (TYP.)
S O
L I C
I T
A T
I O
N
N
O
D E
S I G
N E
D
B
Y
A
S I Z
E
S U
B M
I T
T E
D
B
Y
C O
N T
R A
C H
E C
K E
D
B
Y
D R
A W
N
B
Y
I S
S U
E
D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
M O
O D
Y
A
F B
G
A
M O
O D
Y
A
N
G A
R H
M U
SHEET ID
W
H N
R
A N
S I D
J U
M
Y
C
O R
E
N G
I N
E E
R S
S A
V A
N N
S
T R
I C
T
S A
V A
N N
A H
G
E O
R G
I A
A E
C O
M
S
E R
V I C
E S
I N
C
F F
E R
S O
N
S
T
S
R O
A N
O K
E
V
A
US Army Corps of Engineers ®
C A
T A
G O
D
E
F I L
E
N
A M
E
ISSUED FOR CONSTRUCTION
PROPOSED CHAIN LINK FENCE
EXISTING STORM PIPING
PROPOSED STORM PIPING
EXISTING DROP INLET
EXISTING STORM JUNCTION BOX
PROPOSED STORM JUNCTION BOX
PROPOSED DROP INLET
MH
PROPOSED HEADWALL
RETAINING WALL. SEE
SHEET CS503 FOR DETAIL.
D E
S C
R I P
T I O
N M
A R
K D
A T
E
A
M E
N D
M E
D E
S C
R I P
T I O
N M
A R
K D
A T
E
A
M E
N D
M E
D E
S C
R I P
T I O
N M
A R
K D
A T
E
A
M E
N D
M E
GENERAL NOTES
LOAD CRITERIA
1. STRUCTURE IS DESIGNED IN ACCORDANCE WITH THE
INTERNATIONAL BUILDING CODE, 2015 EDITION.
2. DESIGN LIVE LOADS (REDUCED AS ALLOWED BY THE BUILDING CODE):
ROOF 20 PSF
HANGAR 300 PSF
WHEEL LOAD FROM HH-60G HELICOPTER
OFFICES (INCLUDING PARTITIONS) 65 PSF
MECHANICAL* 150 PSF
STORAGE (LIGHT) 125 PSF
STORAGE (HANGAR) 300 PSF
STAIRS AND CORRIDORS 100 PSF
MEZZANINES 100 PSF
TOILETS 75 PSF
CATWALKS 40 PSF
ELEVATOR MACHINE ROOM 100 PSF
AREAS NOT OTHERWISE SPECIFIED 100 PSF
*OR EQUIPMENT WEIGHT IF GREATER
3. DESIGN SNOW LOAD:
GROUND SNOW LOAD, Pg 0 PSF
4. DESIGN WIND LOADS:
ULTIMATE WIND SPEED, V 115 MPH (THREE SECOND GUST)
NOMINAL WIND SPEED, V 89 MPH (THREE SECOND GUST)
RISK CATEGORY, II
EXPOSURE C
INTERNAL PRESSURE COEFF GCpi +/-0.55 (HANGAR/HMU)
+/- 0.18 (PUMP HOUSE)
HANGAR/HMU SHALL BE CONSIDERED PARTIALLY ENCLOSED WHETHER THE
HANGAR DOORS ARE OPEN OR CLOSED.
COMPONENTS AND CLADDING ULTIMATE WIND LOADS ARE SHOWN ON
S002 FOR THE HANGAR/HMU AND S003 FOR THE FIRE PUMP BUILDING.
5. DESIGN SEISMIC LOADS ARE BASED ON THE FOLLOWING DATA:
MAPPED SHORT PERIOD SPECTRAL RESPONSE ACCELERATION, Ss 0.11
MAPPED 1-SEC PERIOD SPECTRAL RESPONSE ACCELERATION, S1 0.06
SHORT PERIOD DESIGN SPECTRAL RESPONSE ACCELERATION, Sds 0.117 1-SEC PERIOD DESIGN SPECTRAL RESPONSE ACCELERATION, Sd1 0.096
HANGAR/HMU:
RISK CATEGORY II
SEISMIC DESIGN CATEGORY B
SITE CLASS D
BASIC SEISMIC-FORCE-RESISTING SYSTEM STRUCTURAL STEEL SYSTEM
NOT SPECIFICALLY DETAILED FOR SEISMIC RESISTANCE
RESPONSE MODIFICATION FACTOR, R 3
DEFLECTION AMPLIFICATION FACTOR, Cd 3 IMPORTANCE FACTOR Ie 1.0 SEISMIC RESPONSE COEFFICIENT Cs 0.039
ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE
DESIGN BASE SHEAR Cs x W =42 KIPS
PUMP HOUSE:
RISK CATEGORY III
SEISMIC DESIGN CATEGORY B
SITE CLASS D
BASIC SEISMIC-FORCE-RESISTING SYSTEM STRUCTURAL STEEL SYSTEM
NOT SPECIFICALLY DETAILED FOR SEISMIC RESISTANCE
RESPONSE MODIFICATION FACTOR, R 3
DEFLECTION AMPLIFICATION FACTOR, Cd 3 IMPORTANCE FACTOR Ie 1.25 SEISMIC RESPONSE COEFFICIENT Cs 0.039
ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE
DESIGN BASE SHEAR Cs x W = 2 KIPS
6. DESIGN CRANE LOAD
OVERHEAD CRANE CAPACITY 5 TON
END TRUCK WHEEL BASE 24 FOOT
MAX INDIVIDUAL WHEEL LOAD LESS IMPACT 60,000 LB
FOUNDATIONS
1. FOUNDATIONS ARE DESIGNED IN ACCORDANCE WITH THE SUBSURFACE EXPLORATION AND
GEOTECHNICAL ENGINEERING REPORT BY THE SOILS SECTION GEOTECHNICAL & HTRW BRANCH
OF U.S. ARMY ENGINEER DISTRICT, SAVANNAH, DATED FEBRUARY 2019. FOOTING ELEVATIONS
SHOWN REPRESENT THE MINIMUM DEPTH TO WHICH FOOTINGS SHALL BE PLACED. SOFT SOILS
BELOW THE BOTTOM OF FOOTING ELEVATIONS SHALL BE OVER EXCAVATED AND REPLACED WITH
SUITABLE COMPACTED MATERIAL PER THE GEOTECHNICAL REPORT. OVER EXCAVATION SHALL
EXTEND BEYOND THE FOOTING FOOTPRINT A DISTANCE OF AT LEAST FIVE FEET IN ALL DIRECTIONS PER THE GEOTECHNICAL REPORT. WHERE THE DEPTH OF OVER EXCAVATION EXTENDS BELOW THE
WATER TABLE, THE BASE OF THE EXCAVATION MAY HAVE TO BE STABILIZED WITH NON-WOVEN
GEOTEXTILE AND 18 INCHES OF COARSE CRUSHED STONE PER THE GEOTECHNICAL REPORT.
WHERE FOOTINGS ARE REQUIRED TO BE LOWERED MORE THAN 1 FOOT, NOTIFY THE CONTRACTING OFFICER. ALL UNSUITABLE FOUNDATION MATERIAL SHALL BE REMOVED WITH FOOTINGS RESTING ON SUITABLE COMPACTED MATERIAL WITH A MINIMUM BEARING CAPACITY OF 2000 PSF UNLESS
OTHERWISE INDICATED.
2. FX.X INDICATES FOOTING TYPES. SEE FOOTING SCHEDULE FOR SIZE AND REINFORCING.
3. NO FOUNDATION CONCRETE SHALL BE INSTALLED UNTIL ALL FOUNDATION WORK HAS BEEN COORDINATED WITH UNDERGROUND UTILITIES. FOOTINGS SHALL BE LOWERED WHERE REQUIRED TO AVOID UTILITIES.
WHERE FOOTINGS ARE REQUIRED TO BE LOWERED MORE THAN 1 FOOT, NOTIFY THE ENGINEER OF RECORD.
4. TO MINIMIZE WEATHERING, THE LAST 6 INCHES OF EXCAVATION FOR ALL FOOTINGS SHALL BE MADE IMMEDIATELY
PRIOR TO PLACEMENT OF FOOTINGS.
5. UNLESS OTHERWISE SHOWN, THE CENTERLINES OF ALL PIERS AND COLUMN FOOTINGS SHALL BE LOCATED ON
COLUMN CENTERLINES.
CONCRETE
1. CONCRETE STRENGTH:
ALL CONCRETE NOT OTHERWISE SPECIFIED f'c = 4000 psi FOOTINGS f'c = 3000 psi
2. REINFORCING BARS
ASTM A 615 GRADE 60, DEFORMED Fy = 60 KSI
3. REINFORCEMENT SHALL BE DETAILED AND PLACED IN ACCORDANCE WITH ACI SP-66-04. DEVELOPMENT AND SPLICE LENGTHS ARE IN TENSION UNLESS OTHERWISE INDICATED. TENSION LAP SPLICES SHALL BE AS TABULATED
IN THE SPLICE LENGTH TABLE BELOW. UNLESS OTHERWISE INDICATED.
f'c (psi) BAR TYPE #3 #4 #5 #6 #7 #8 #9 #10 #11
3000 TOP BARS 28 37 47 56 81 93 105 118 131
3000 OTHER BARS 22 29 36 43 63 72 81 91 101
4000 TOP BARS 24 32 40 48 70 80 91 102 113
4000 OTHER BARS 19 25 31 37 54 62 70 79 87
TOP BARS ARE HORIZONTAL REINFORCEMENT PLACED SO THAT MORE THAN 12 INCHES OF FRESH CONCRETE IS
CAST IN THE MEMBER BELOW THE BAR.
4. CONTINUOUS REINFORCING IN WALLS AND SLABS MAY BE SPLICED, AS REQUIRED, PROVIDING BARS ARE OF THE LONGEST PRACTICABLE LENGTH AND SPLICES ARE SHOWN ON REINFORCING SHOP DRAWINGS. WHEREVER POSSIBLE, SPLICES SHALL BE STAGGERED. FIELD CUTTING OF REINFORCEMENT WILL NOT BE PERMITTED.
5. UNLESS OTHERWISE SHOWN, BARS AT WALL AND CONTINUOUS FOOTING CORNERS AND INTERSECTIONS SHALL BE DETAILED AS SHOWN ON FIGURE 15 OF ACI SP-66-04. CORNER BARS SHALL BE DETAILED AS SHOWN FOR OUTSIDE LOADED
CORNERS. INTERSECTIONS SHALL BE DETAILED WITHOUT DIAGONAL BARS.
6. PROVIDE CONCRETE COVER FOR REINFORCING AS FOLLOWS, U.N.O.:
CAST AGAINST EARTH 3”
EXPOSED TO EARTH OR WEATHER:
#5 AND SMALLER BARS AND WWR 1-1/2”
#6 AND LARGER BARS 2”
NOT EXPOSED TO EARTH OR WEATHER:
SLABS AND WALLS:
#11 AND SMALLER AND WWR 3/4”
#14 AND LARGER 1-1/2”
BEAMS AND COLUMNS 1-1/2”
7. PROVIDE DOWELS TO MATCH REINFORCEMENT SIZE AND SPACING INDICATED FOR ALL STRUCTURAL ELEMENTS, UNLESS
OTHERWISE INDICATED.
8. MAJOR CONSTRUCTION JOINTS ARE SHOWN ON THE DRAWINGS. INTERMEDIATE JOINTS IN WALLS, SLABS, AND FLOOR FRAMING ARE NOT SHOWN. CONSTRUCTION JOINTS MAY BE ADDED, OMITTED OR RELOCATED IF PROPERLY DETAILED ON
SHOP DRAWINGS AND APPROVED BY THE OWNER’S REPRESENTATIVE.
9. SEE ARCHITECTURAL AND MECHANICAL DRAWINGS FOR LOCATIONS OF OPENINGS AND SLEEVES IN CONCRETE WALLS AND SUPPORTED FLOORS. SPREAD REINFORCEMENT AT OPENINGS AND SLEEVES UNLESS OTHERWISE SHOWN. DO NOT CUT REINFORCEMENT. SEE TYPICAL REINFORCEMENT DETAILS FOR OPENINGS IN SLABS AND WALLS FOR ADDITIONAL REQUIREMENTS.
10.REINFORCE FLOOR SLABS ON GRADE IN ACCORDANCE WITH THE FOLLOWING SCHEDULE, UNLESS OTHERWISE NOTED. PLACE
REINFORCEMENT 2 INCHES BELOW TOP OF SLAB UNLESS OTHERWISE NOTED.
SLAB THICKNESS REINFORCEMENT
5" 6X6-W2.9XW2.9 WWF
10" #4@12 EW, TOP
11.IN SLABS-ON-GRADE, PROVIDE 2-#4X4'-0" DIAGONAL BARS IN THE MIDDLE OF THE SLAB AT EACH CORNER OF OPENINGS OVER
1'-0" SQUARE AND AT RE-ENTRANT CORNERS.
12.PROVIDE CONTROL JOINTS AT 22 FEET O.C. MAX FOR THE 10 INCH SLAB AND 14 FEET O.C. MAX FOR THE 5 INCH SLAB.
LOCATE CONTROL JOINTS TO FORM APPROXIMATE SQUARE PANELS WITH THE LENGTH OF ONE SIDE NOT EXCEEDING THE ADJACENT SIDE BY A FACTOR OF 1.5. CONTROL JOINTS MAY BE CONTRACTION JOINTS, CONSTRUCTION JOINTS, OR EXPANSION JOINTS.
13.PROVIDE WATERSTOPS IN ALL CONSTRUCTION JOINTS AT OR BELOW GRADE.
14.DEPRESS FLOOR SLABS AS REQUIRED; SEE ARCHITECTURAL DRAWINGS FOR LOCATION AND DEPTH OF DEPRESSED AREAS.
15.CHAMFER EDGES OF PERMANENTLY EXPOSED CONCRETE SURFACES 3/4-INCH, UNO.
16.SLABS AND BEAMS OR JOISTS SHALL BE CAST MONOLITHICALLY UNLESS OTHERWISE INDICATED.
HIGH MAST LIGHTING FOUNDATIONS
1. CONTRACTOR SHALL PERFORM A SOIL BORING WHERE THE HIGH MAST LIGHT WILL BE RELOCATED. THE SOIL
BORING SHALL EXTEND 30 FEET BELOW GRADE AND STANDARD PENETRATION TEST (SPT) SHALL BE PERFORMED PER ASTM D-1586 EVERY 2.5 FEET FOR THE TOP 15 FEET OF THE BORING AND AT 5 FOOT INTERVALS THEREAFTER. PERFORM LAB TESTING TO DETERMINE SOIL CLASSIFICATION AND INDEX PROPERTIES (MOISTURE CONTENT AND ATTERBERG LIMITS).
LEAVE HOLE OPEN LONG ENOUGH TO OBTAIN A STABILIZED GROUND WATER LEVEL. SUBMIT THE FOLLOWING INFORMATION
TO THE EOR FOR DEEP FOUNDATION CONFIRMATION.
A) EFFECTIVE UNIT WEIGHT (lbs/in^3) B) UNDRAINED COHESION (psi)
C) STRAIN FACTOR (E50)
D) P-Y MODULUS (lbs/in^3) E) FRICTION ANGLE (deg)
2. CONTRACTOR SHALL VERIFY THE FOLLOWING INFORMATION FOR THE EXISTING HIGH MAST POLE AND PROVIDE
THIS INFORMATION TO THE EOR FOR DEEP FOUNDATION DESIGN CONFIRMATION.
A) NUMBER OF ANCHOR BOLTS
B) DIAMETER OF ANCHOR BOLTS
C) DIAMETER OF POLE BASE PLATE
D) DIAMETER OF POLE AT THE POLE BASE
E) DIAMETER OF POLE AT THE TOP OF THE POLE
F) MANUFACTURER’S DATA FOR ALL LIGHTS SUPPORTED ON THE HIGH MAST POLE
3. FOUNDATION FOR HIGH MAST LIGHTING IS SHOWN IN DETAIL 3/S-302. FOUNDATION SIZE, DEPTH AND REINFORCEMENT WILL BE VERIFIED BY THE EOR ONCE THE INFORMATION IN NOTES 1 AND 2 ABOVE ARE PROVIDED TO THE EOR. INSTALLATION OF THE FOUNDATION SHALL NOT BE PERFORMED UNTIL THE CONTRACTOR IS NOTIFIED THAT EOR HAS COMPLETED THE FOUNDATION CONFIRMATION. CURRENT FOUNDATION DESIGN IS SUBJECT TO CHANGE BASED ON INFORMATION RECEIVED IN NOTES 1 AND 2
ABOVE.
MASONRY
1. MASONRY STRENGTH
MASONRY SYSTEM COMPRESSIVE STRENGTH f'm = 1500 psi
MORTAR SHALL BE TYPE S
GROUT COMPRESSIVE STRENGTH 2000 psi
2. REINFORCING BARS IN MASONRY SHALL BE FULLY GROUTED FOR THEIR ENTIRE LENGTH AND SHALL BE LAP SPLICED 48 BAR
DIAMETERS.
3. UNLESS OTHERWISE NOTED OR SHOWN, PROVIDE CMU LINTELS OVER OPENINGS IN CMU WALLS IN ACCORDANCE WITH TYPICAL
CMU LINTEL SCHEDULE.
4. BRACE CMU WALLS DURING CONSTRUCTION UNTIL FLOOR OR ROOF STRUCTURE IS ERECTED AND CONNECTED TO WALL
5. UNLESS OTHERWISE SHOWN, PROVIDE SOLID MASONRY BLOCK COURSES, CONSISTING OF SOLID BLOCKS OR GROUT FILLED BLOCKS FOR BEARING UNDER STRUCTURAL MEMBERS IN ACCORDANCE WITH THE FOLLOWING SCHEDULE:
THREE COURSES UNDER STEEL BEAMS AND COLUMNS (2'-0" EACH SIDE OF MEMBER)
STEEL
1. MATERIAL STRENGTH
WIDE FLANGE SHAPES ASTM A 992 Fy = 50 KSI STRUCTURAL RECTANGULAR TUBING ASTM A 500 GRADE B Fy = 46 KSI (NOTED AS “HSS 4x4x1/4”)
ALL OTHER STRUCTURAL STEEL ASTM A 36 Fy = 36 KSI
2. THE CENTERLINES OF ALL COLUMNS AND BEAMS SHALL BE LOCATED ON COLUMN LINES UNLESS OTHERWISE SHOWN.
3. BEAMS SHALL BE FABRICATED AND INSTALLED WITH THE NATURAL CAMBER UP.
4. BOLTS SHALL BE ¾ INCH DIAMETER, TYPE A325N, UNLESS OTHERWISE INDICATED.
5. ANCHOR BOLTS SHALL CONFORM TO ASTM F1554, GRADE 36, UNLESS NOTED OTHERWISE. SWAGED ANCHOR BOLTS
AND ANCHOR BOLTS WITH HOOKED END ANCHORAGE ARE NOT ALLOWED.
6. SHEAR CONNECTIONS FOR SIMPLY SUPPORTED BEAMS SHALL BE DESIGNED FOR THE LRFD REACTIONS INDICATED ON THE
FRAMING PLANS. WHERE NONE ARE INDICATED USE 10 KIPS.
7. WELDING ELECTRODES SHALL CONFORM TO REQUIREMENTS SHOWN IN TABLE 3.2 OF AWS D1.1:2015, AND FILLER METAL SHALL HAVE A MINIMUM YIELD STRENGTH OF 70 KSI. WHERE WELD SIZE IS NOT GIVEN WELD SIZE SHALL BE A MINIMUM IN
ACCORDANCE WITH TABLE 5.7 OF AWS D1.1:2015.
8. WHERE THE WORK OF OTHER TRADES REQUIRES CUTS, HOLES, ETC., IN STRUCTURAL STEEL MEMBERS, CUTS, HOLES, ETC., SHALL BE MADE IN THE SHOP AND SHALL BE SHOWN ON THE SHOP DRAWINGS. MAKING HOLES OR CUTS IN STRUCTURAL STEEL MEMBERS IN THE FIELD WILL NOT BE PERMITTED WITHOUT SPECIFIC APPROVAL OF THE OWNER’S REPRESENTATIVE.
9. WHERE PARTITIONS OF ANY MATERIAL ABUT STEEL COLUMN ENCASEMENTS, INCREASE THE DISTANCE FROM STEEL COLUMN TO FACE OF ENCASEMENT AS REQUIRED TO PROVIDE AN UNBROKEN SURFACE FOR THE WALL FINISH.
PRE-ENGINEERED METAL BUILDING
1. DESIGN THE BUILDING SYSTEM(S) IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE, 2015 EDITION AND THE METAL
BUILDING SYSTEMS MANUAL, 2012 EDITION.
2. DESIGN THE BUILDING SYSTEM FOR THE LIVE LOADS OR SNOW LOADS (WHICHEVER IS GREATER) INDICATED AND A COLLATERAL DEAD LOAD OF 10 PSF IN ADDITION TO THE BUILDING DEAD LOADS, WIND LOADS AND SEISMIC LOADS. COLLATERAL LOAD INCLUDES LIGHTING AND PIPING 2 INCHES IN DIAMETER AND SMALLER. PARAMETERS FOR THE DEVELOPMENT OF THE SNOW, WIND, AND SEISMIC LOADS ARE LISTED IN THE GENERAL NOTES. INCLUDE THE EFFECTS OF UNBALANCED SNOW LOAD, SNOWDRIFT, SLIDING SNOW, RAIN ON SNOW AND WINDWARD AND LEEWARD WIND PRESSURE AND SUCTION LOADS. ROOF PURLINS SHALL BE DESIGNED FOR AN ADDITIONAL CONCENTRATED LIVE LOAD OF 250 POUNDS LOCATED ANYWHERE ALONG THE LENGTH OF THE PURLIN OR THE ACTUAL WEIGHT OF FANS, FOAM GENERATORS, PIPING GREATER THAN 2 INCHES IN
DIAMETER OR OTHER HANGING EQUIPMENT, WHICHEVER IS GREATER.
3. LOAD COMBINATIONS SHALL BE IN ACCORDANCE WITH THE APPLICABLE BUILDING CODE UNLESS THE MBMA METAL BUILDING
SYSTEMS MANUAL (2012) LOAD COMBINATIONS ARE MORE STRINGENT.
4. DESIGN THE BUILDING SYSTEM WITH HINGED COLUMN BASES. FIXED BASE COLUMNS ARE NOT ALLOWED.
5. BUILDING LATERAL DEFLECTIONS AND RACKING LIMITS SHALL BE IN ACCORDANCE WITH "SERVICEABILITY CONSIDERATIONS" SUMMARY TABLES CONTAINED IN AISC STEEL DESIGN GUIDE SERIES 3 "SERVICEABILITY DESIGN CONSIDERATIONS FOR STEEL BUILDINGS" 2003, UNO. DEFLECTIONS SHALL BE LIMITED TO ENSURE THAT BUILDING COMPONENTS DO NOT CONTACT INTERIOR PARTITIONS. DEFLECTION LIMITS SHALL NOT EXCEED DEFLECTION TOLERANCES OF EQUIPMENT SUPPORTED BY THE BUILDING.
6. THE BUILDING FOUNDATIONS AND ANCHOR BOLTS HAVE BEEN DESIGNED FOR THE REACTIONS SHOWN. REDESIGN THE FOUNDATIONS AND ANCHOR BOLTS IF THE REACTIONS FOR THE BUILDING FURNISHED EXCEED THE INDICATED REACTIONS BY 10 PERCENT. CALCULATIONS SEALED BY A PROFESSIONAL ENGINEER SHALL BE SUBMITTED FOR REVIEW. DO NOT PLACE FOUNDATIONS PRIOR TO THE REVIEW AND APPROVAL OF THE BUILDING SYSTEM FOUNDATION LOADINGS.
7. PIER AND FOOTING SIZES AND LOCATION SHOWN ARE BASED UPON ASSUMPTIONS OF THE BUILDING SYSTEM'S COMPONENTS, CONFIGURATIONS AND LOADS. COORDINATE ALL FINAL DETAILS AND DIMENSIONS TO ENSURE THAT THE FOUNDATION SYSTEM
IS COMPATIBLE WITH THE BUILDING SYSTEM USED.
8. DESIGN AND PROVIDE STRUCTURAL MEMBERS FOR THE SUPPORT OF HVAC UNITS, DUCTS, FANS, PIPING, ELECTRICAL
COMPONENTS, SUPPORTED PARTITIONS, ETC.
9. COORDINATE VERTICAL DEFLECTIONS WITH THE VERTICAL LIFT FABRIC DOOR.
10.COORDINATE, DESIGN AND PROVIDE ANY MISCELANEOUS STEEL REQUIRED TO SUPPORT THE VERTICAL LIFT FABRIC DOOR.
SPECIAL INSPECTIONS
1. SPECIAL INSPECTIONS WILL BE PERFORMED IN ACCORDANCE WITH THE STATEMENT OF SPECIAL INSPECTIONS
2. CONTRACTOR SHALL DIRECTLY EMPLOY AND PAY FOR SERVICES OF THE SPECIAL INSPECTORS TO PERFORM REQUIRED
SPECIAL INSPECTIONS.
3. THE FOLLOWING GENERAL TYPES OF WORK REQUIRE SPECIAL INSPECTION: (REFER TO STATEMENT OF SPECIAL INSPECTIONS
FOR DETAILED INSPECTION REQUIREMENTS)
FOUNDATIONS
CONCRETE
REINFORCING STEEL
FORMWORK
POST-INSTALLED CONCRETE ANCHORS
MASONRY
STRUCTURAL STEEL
STRUCTURAL WELDING
HIGH STRENGTH BOLTS
FLOOR AND ROOF DECK ATTACHMENT
STEEL DECK
1. DESIGN FORM DECK IN ACCORDANCE WITH THE FOLLOWING:
DEPTH 1.5 in
MINIMUM GAGE 24
MINIMUM SECTION MODULUS, Sp 0.132 in3
MINIMUM SECTION MODULUS, Sn 0.120 in3
MINIMUM MOMENT OF INERTIA 0.108 in4
2. FORM DECK CONNECTIONS: IN ACCORDANCE WITH TYPICAL FORM DECK ATTACHMENT DETAIL
3. DESIGN FLOOR DECK IN ACCORDANCE WITH THE FOLLOWING:
DEPTH 2 in
MINIMUM GAGE 22
COMPOSITE
MINIMUM SECTION MODULUS, Sp 0.263 in3
MINIMUM SECTION MODULUS, Sn 0.266 in3
MINIMUM MOMENT OF INERTIA 0.321 in4
4. FLOOR DECK CONNECTIONS: IN ACCORDANCE WITH TYPICAL COMPOSITE FLOOR DECK ATTACHMENT DETAIL.
5. ALL METAL DECK HAS BEEN DESIGNED TO BE CONTINUOUS OVER THREE SPANS MINIMUM, AND SHALL BEAR AT LEAST 1 ½ INCHES MINIMUM ON STEEL SUPPORTS OR MORE AS REQUIRED BY DECK MANUFACTURER. FOR ONE OR TWO SPAN CONDITIONS, THE CONTRACTOR SHALL PROVIDE SHORING AS REQUIRED, OR FURNISH HIGHER GAGE DECK AS REQUIRED TO SUPPORT ALL THE APPLICABLE LOADS. CONTRACTOR SHALL SUBMIT ALTERNATE FOR APPROVAL. CONTRACTOR SHALL ENSURE THAT CONSTRUCTION LOADS ON STEEL DECK DO NOT EXCEED SDI PUBLISHED CONSTRUCTION LOAD CRITERIA.
6. THE CONTRACTOR SHALL VERIFY THE SIZE AND LOCATION OF ALL OPENINGS, SLEEVES, INSERTS, ETC., WITH SHOP DRAWINGS OF THE EQUIPMENT TO BE INSTALLED. SEE MECHANICAL DRAWINGS FOR LOCATIONS OF PIPE SLEEVES. SEE ARCHITECTURAL
DRAWINGS FOR LOCATIONS OF OPENINGS IN ROOF.
POST INSTALLED ANCHORS
1. POST INSTALLED ANCHORS HAVE BEEN DESIGNED WITH HILTI ANCHORS (NOTED BELOW) AS THE BASIS OF DESIGN. INSTALL
ANCHORS PER THE MANUFACTURER'S PRINTED INSTALLATION INSTRUCTIONS.
A. EXPANSION ANCHORS: KWIK BOLT ((3 OR TZ))
B. SLEEVE ANCHORS: HLC SLEEVE ANCHOR
C. ADHESIVE ANCHORS: HIT HY-200/HIT-ICE
D. SCREEN TUBE ANCHORS: HIT HY-70
2. CONTRACTOR MAY PROVIDE EQUIVALENT ANCHORS WITH SIZE AND FINISH AS NOTED AND EQUIVALENT SHEAR AND TENSION CAPACITIES AFTER MODIFICATION DUE TO EMBEDMENT, SPACING AND EDGE DISTANCES AT THE DISCRETION OF THE OWNER’S
REPRESENTATIVE.
3. ALL ADHESIVE ANCHORS FOR REINFORCING SHALL HAVE BEEN TESTED IN ACCORDANCE WITH ACI 355.4 AND ICC-ES AC308 FOR
CRACKED CONCRETE AND SEISMIC APPLICATIONS.
4. DESIGN ADHESIVE BOND STRENGTH FOR ADHESIVE ANCHORS IN CONCRETE HAS BEEN BASED ON ACI 355.4, TEMPERATURE CATEGORY B WITH INSTALLATIONS INTO DRY HOLES DRILLED USING A CARBIDE DRILL BIT INTO CRACKED CONCRETE THAT HAS
CURED FOR AT LEAST 21 DAYS.
5. ADHESIVE ANCHORS REQUIRING CERTIFIED INSTALLATIONS SHALL BE INSTALLED BY A CERTIFIED ADHESIVE ANCHOR INSTALLER PER ACI 318 D.9.2.2. INSTALLATIONS REQUIRING CERTIFIED INSTALLERS SHALL BE INSPECTED PER ACI 318 D.9.2.4.
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
-D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
C
AT
EG
O
R Y
C O
D E
1 2 3 4 5
A
M O
O D
Y
AF
B, G
A M
O O
D Y
AF
B
H
AN
G A
R /H
M U
SA
VA
N N
AH
D
IS
TR
IC
T
SA
VA
N N
A H
, G
EO
R G
IA
AE
C
O M
S
ER
VI
C
E S, IN
C
S J
EF
FE
R
SO
N S
T
ST
E
R
O
AN
O
KE
V A
1-
JU
LY
2, 7 8 9 10
B
C
D
E
F
G
C S
R
1-
5-
W
2H N
-1 9-
R -3
ISSUED FOR CONSTRUCTION
S-001
G
EN
ER
AL
N O
TE
S
BS
B
M W
R
H M
F
M
AR
K D
E
SC
R
IP
TI
O
N D
A
TE
R
EV
IS
ED
IA
W A
M
EN
D M
EN
T
/2
7/
A B C D E F G H I
C.2 F.7
MATCHLINE-SEE SH 1 / S-101BMATCHLINE-SEE SH 1 / S-101B
MATCHLINE-SEE SH 1 / S-101DMATCHLINE-SEE SH 1 / S-101D
SB3
SB2SB2
SF2SF2
2.8
F.8
3.4
A.0
3.3
G.6
A.5 H.5
S-301
S-301
S-301
F9 F7.5 F7.5 F9 P1 P1 P1
P1
F5
F4
F6
F6 F6
F7.5
F6 F6
F6
F6 F6 F6
F5 P2
P2
P3
P4 P4
P4
P4 P4
P4
P4 P4 P3
P2
F7 F7F8
F7
F7F7
F6
F7.5 P4
SB7
SB6
SF2
SL
O
PE
SL
O
PE
5" SLAB
5" SLAB 10" SLAB
CLJ
SB6
SB2SB210" SLAB 5" SLAB
10" SLAB
5" SLAB
10" SLAB
10" SLAB
SB1
7'
3/
8" 7'
/8
3.6
1' - 4" 1' - 4"
S-2011
S-302
F4F3 F3 C1 C1 C1
F3
F3
C1
SB14
SB13
S-302
S-302
S-302
S-501 SB1
6' - 5 3/8" 3' - 1 3/4"
SB16
SB16
SB8
GENERAL NOTES THIS SHEET:
A. SEE SHEET S-001 FOR GENERAL NOTES.
B. SEE S-500 SERIES FOR TYPICAL DETAILS
C. SEE S-601 FOR FOOTING AND PIER SCHEDULES.
D. TOP OF SLAB ELEVATION IS 0'-0" = 228.25'
E. TOP OF FOOTING ELEVATION IS -2'-0" UNO.
F. ANGLE LINTEL OVER DOORS AND WINDOWS IN CMU
WALL USE L7X4X3/8 LLH ANCHORED TO CMU WITH
3/8" Ø EXPN AHR WITH 2 1/2" EMBEDMENT AT 2'-0" ON
CENTER.
8' 4' 0 8' 16' 1/8"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
-D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
C
AT
EG
O
R Y
C O
D E
1 2 3 4 5
A
GRAPHIC SCALES
M O
O D
Y
AF
B, G
A M
O O
D Y
AF
B
H
AN
G A
R /H
M U
SA
VA
N N
AH
D
IS
TR
IC
T
SA
VA
N N
A H
, G
EO
R G
IA
AE
C
O M
S
ER
VI
C
E S, IN
C
S J
EF
FE
R
SO
N S
T
ST
E
R
O
AN
O
KE
V A
1-
JU
LY
2, 7 8 9 10
B
C
D
E
F
G
C S
R
N
1-
5-
W
2H N
-1 9-
R -3
KEYPLAN
A
B
C
D
ISSUED FOR CONSTRUCTION
S-101C
FO
U
N D
AT
IO
N P
LA
N
AR
EA
C
BS
B
M W
R
H M
F
1/8" = 1'-0"
FOUNDATION PLAN-AREA C
SHEET KEYNOTES
SB1 10" SLAB ON GRADE REINFORCED WITH
#4@12 EW
SB2 5" SLAB ON GRADE REINF W/
6X6-W2.9XW2.9 WWR
SB3 PEMB COLUMN
SB6 THICKENED SLAB AT CMU PARTITIONS,
TYP, SEE 4/S-501
SB7 THICKENED SLAB AT LOAD BEARING CMU,
SEE 4/S-501
SB8 TOP OF FOOTING ELEVATION IS -6'-0"
SB13 THICKENED SLAB AT STAIR STRINGER,
SEE 6/S-501
SB14 SLAB DEPRESSION FOR WALKOFF MAT,
SEE 11/S-501
SB16 1'-7" EQUIPMENT PAD SEE 8/S-501
SF2 X-BRACE BY PEMB MANUFACTURER
M
AR
K D
E
SC
R
IP
TI
O
N D
A
TE
R
EV
IS
ED
IA
W A
M
EN
D M
EN
T
/2
7/
C.2 F.7
E.7
MATCHLINE-SEE SH 1 / S-101CMATCHLINE-SEE SH 1 / S-101C
SB1SB1
G.9E.5D.4B.1
7.2
F.6
6.2
7.8
F.8
G.6A.5 H.5
C1 C1
C1
C1
S-301
S-301
S-301
F6
F6 F6
F7.5
F6 F6
F6
F6 F6 F6
P3
P4 P4
P4
P4 P4
P4
P4 P4 P3
F9.5
F9.5
F6 F9 F9
F6
F9.5F11
F4
F11
F11 F11
F4 F9.5
P5
P5
P2 P2
P4
P2
P4
P2
P5
P4
P5
P4
F7.5 P4
5" SLAB
SF5
SF5
CLJ
SB2SB210" SLAB 5" SLAB
10" SLAB
5" SLAB
10" SLAB
5" SLAB
10" SLAB
10" SLAB
1' - 4"
1'
4"
S-3018
S-301
S-3018 S-301
S-201
S-201
S-201
1' - 4"
SB11
SB11
7.3
D.37.4
F4 C1C1
C1
SB15
S-302
S-302
S-302
S-301
SIM
S-301
SIM
GENERAL NOTES THIS SHEET:
A. SEE SHEET S-001 FOR GENERAL NOTES.
B. SEE S-500 SERIES FOR TYPICAL DETAILS
C. SEE S-601 FOR FOOTING AND PIER SCHEDULES.
D. TOP OF SLAB ELEVATION IS 0'-0" = 228.25'
E. TOP OF FOOTING ELEVATION IS -2'-0" UNO.
F. ANGLE LINTEL OVER DOORS AND WINDOWS IN CMU
WALL USE L7X4X3/8 LLH ANCHORED TO CMU WITH
3/8" Ø EXPN AHR WITH 2 1/2" EMBEDMENT AT 2'-0" ON
CENTER.
8' 4' 0 8' 16' 1/8"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
-D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
C
AT
EG
O
R Y
C O
D E
1 2 3 4 5
A
GRAPHIC SCALES
M O
O D
Y
AF
B, G
A M
O O
D Y
AF
B
H
AN
G A
R /H
M U
SA
VA
N N
AH
D
IS
TR
IC
T
SA
VA
N N
A H
, G
EO
R G
IA
AE
C
O M
S
ER
VI
C
E S, IN
C
S J
EF
FE
R
SO
N S
T
ST
E
R
O
AN
O
KE
V A
1-
JU
LY
2, 7 8 9 10
B
C
D
E
F
G
C S
R
N
1-
5-
W
2H N
-1 9-
R -3
KEYPLAN
A
B
C
D
ISSUED FOR CONSTRUCTION
S-101D
FO
U
N D
AT
IO
N P
LA
N
AR
EA
D
BS
B
M W
R
H M
F
1/8" = 1'-0"
FOUNDATION PLAN-AREA D
SHEET KEYNOTES
SB1 10" SLAB ON GRADE REINFORCED WITH
#4@12 EW
SB2 5" SLAB ON GRADE REINF W/
6X6-W2.9XW2.9 WWR
SB11 OIL/WATER SEPARATOR IN SOG SEE
PLUMBING
SB15 TOP OF FOOTING ELEVATION IS -3'-0"
SF5 PORTAL FRAME BY PEMB MANUFACTURER
M
AR
K D
E
SC
R
IP
TI
O
N D
A
TE
R
EV
IS
ED
IA
W A
M
EN
D M
EN
T
/2
7/
C.2 F.7
MATCHLINE-SEE SH 1 / S-102B MATCHLINE-SEE SH 1 / S-102B
SF2
SF9
2.8
A.5 H.5
S-310
S-310
SF2
SF2 SF2 SF2
3.6
S-102C
S-102C
SF12
SF14
SF14
SF14
GENERAL NOTES THIS SHEET:
A. SEE SHEET S-001 FOR GENERAL NOTES.
B. SEE S-500 SERIES FOR TYPICAL DETAILS
C. FINISHED T/SLAB EL = 20'-3" A.F.F
D. COORDINATE DIMENSIONS, OPENINGS, SECTIONS
AND DETAILS WITH ARCH AND MEP DRAWINGS.
E. ALL STEEL FLOOR FRAMING SHALL BE DESIGNED
AND PROVIDED BY THE PEMB MANUFACTURER U.N.O.
DESIGN LIVE LOADS FOR THE FLOOR SHALL BE 80 PSF,
REDUCIBLE.
W 8X
H O
IS
T
BE
AMSF11 1
S-310
SIM
F
SF10
S-310
SIM
8' 4' 0 8' 16' 1/8"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
-D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
C
AT
EG
O
R Y
C O
D E
1 2 3 4 5
A
GRAPHIC SCALES
M O
O D
Y
AF
B, G
A M
O O
D Y
AF
B
H
AN
G A
R /H
M U
SA
VA
N N
AH
D
IS
TR
IC
T
SA
VA
N N
A H
, G
EO
R G
IA
AE
C
O M
S
ER
VI
C
E S, IN
C
S J
EF
FE
R
SO
N S
T
ST
E
R
O
AN
O
KE
V A
1-
JU
LY
2, 7 8 9 10
B
C
D
E
F
G
C S
R
N
1-
5-
W
2H N
-1 9-
R -3
KEYPLAN
A
B
C
D
ISSUED FOR CONSTRUCTION
S-102C
SE
C
O N
D F
LO
O
R F
R
AM
IN
G
P
LA
N
AR
EA
C
BS
B
M W
R
H M
F
1/8" = 1'-0"
SECOND FLOOR FRAMING PLAN - AREA C
SHEET KEYNOTES
SF2 X-BRACE BY PEMB MANUFACTURER
SF9 3-1/2" CONCRETE ON 2" COMPOSITE DECK
(5-1/2" TOTAL THICKNESS). REINFORCED
WITH 6X6-W2.9XW2.9 WWR.
SF10 8" CONC SLAB REINF W/ #5@12 EW. TOP
OF SLAB EL=32'-11" AFF.
SF11 8" CONC SLAB REINF W/ #5@12 EW. TOP
OF SLAB EL=34'-11" AFF.
SF12 8" REINFORCED CMU WALLS, SEE ARCH
FOR LOCATION.
SF14 #4X4'-0" @ 12" OC
1/4" = 1'-0"S-102C
2 ELEVATOR CAP PLAN
1/4" = 1'-0"S-102C
3 FLIGHT VAULT CAP
M
AR
K D
E
SC
R
IP
TI
O
N D
A
TE
R
EV
IS
ED
IA
W A
M
EN
D M
EN
T
/2
7/
A B C
SB3
SF5 SF2
13' - 8" 13' - 8"
SB9
SB9
F4.5 P5
F4.5 P2
P6 F4.5
P2 F4.5 F4.5
P2
P2 F4.5
S-301
S-301
S-301
S-301
CLJ
SIM
1'
7/
8" 1'
7/ 8"
1' - 3 7/8"1' - 3 7/8"
SB10
SB2SB2
1'
0"
S-201
S-201
S-301
SIM
S-301
SIM
GENERAL NOTES THIS SHEET:
A. SEE SHEET S-001 FOR GENERAL NOTES.
B. SEE S-500 SERIES FOR TYPICAL DETAILS
C. SEE S-600 SERIES FOR PIER AND FOOTING SCHEDULE.
D. FINISHED FLOOR ELEVATION IS 0'-0" = 228.0'.
E. TOP OF FOOTING ELEVATION IS -2'-0", UNO.
8' 4' 0 8' 16' 1/8"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
-D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
C
AT
EG
O
R Y
C O
D E
1 2 3 4 5
A
GRAPHIC SCALES
M O
O D
Y
AF
B, G
A M
O O
D Y
AF
B
H
AN
G A
R /H
M U
SA
VA
N N
AH
D
IS
TR
IC
T
SA
VA
N N
A H
, G
EO
R G
IA
AE
C
O M
S
ER
VI
C
E S, IN
C
S J
EF
FE
R
SO
N S
T
ST
E
R
O
AN
O
KE
V A
1-
JU
LY
2, 7 8 9 10
B
C
D
E
F
G
C S
R
N
1-
5-
W
2H N
-1 9-
R -3
ISSUED FOR CONSTRUCTION
S-111
FO
U
N D
AT
IO
N P
LA
N
FI
R E
PU
M
P B
U
IL
D
IN
G
BS
B
M W
R
H M
F
SHEET KEYNOTES
SB2 5" SLAB ON GRADE REINF W/
6X6-W2.9XW2.9 WWR
SB3 PEMB COLUMN
SB9 1'-3" EQUIPMENT PAD SEE 8/S-501
SB10 6" EQUIPMENT PAD SEE 8/S-501
SF2 X-BRACE BY PEMB MANUFACTURER
SF5 PORTAL FRAME BY PEMB MANUFACTURER
1/8" = 1'-0"
FOUNDATION PLAN - FIRE PUMP BUILDING
M
AR
K D
E
SC
R
IP
TI
O
N D
A
TE
R
EV
IS
ED
IA
W A
M
EN
D M
EN
T
/2
7/
A.0
1'
4"
SEE PLAN FOR FTG
MARK AND TOP OF
FTG EL
4-#7
3-#3 TIES
FINISHED GRADE
SEE CIVIL
SPLIT FACE CMU
SEE ARCH
PEMB COL
GROUT SOLID
BELOW GRADE
(X 1'-4")
2' - 4"
6"
CMU WALL REINF
SEE 4/S-503, UNO
2' - 0"
3" 2"
6" 6"
3" 3"
6'
#4 TIES @ 6
28-#8
2" DIAMETER
ASTM F1554, GR 55
ANCHOR BOLTS
FINISHED GRADE
SEE CIVIL
'-8
2' - 3"
3" CLR
ANCHOR BOLTS
COORDINATE LAYOUT
WITH EXISTING POLE
BASEPLATE
A A
SECTION A-A
NOTE: FOR HIGH MAST LIGHT POLE LOCATION SEE SHEET ES-104.
12" 6" 0 1' 2' 3' 3/4"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
-D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
C
AT
EG
O
R Y
C O
D E
1 2 3 4 5
A
GRAPHIC SCALES
M O
O D
Y
AF
B, G
A M
O O
D Y
AF
B
H
AN
G A
R /H
M U
SA
VA
N N
AH
D
IS
TR
IC
T
SA
VA
N N
A H
, G
EO
R G
IA
AE
C
O M
S
ER
VI
C
E S, IN
C
S J
EF
FE
R
SO
N S
T
ST
E
R
O
AN
O
KE
V A
1-
JU
LY
2, 7 8 9 10
B
C
D
E
F
G
C S
R
1-
5-
W
2H N
-1 9-
R -3
ISSUED FOR CONSTRUCTION
S-302
SE
C
TI
O
N S
AN
D
D
ET
AI
LS
BS
B
M W
R
H M
F
3/4" = 1'-0"S-302
1 SECTION
3/4" = 1'-0"S-302
2 SECTION
3/4" = 1'-0"S-302
3 HIGH MAST LIGHT FOUNDATION
M
AR
K D
E
SC
R
IP
TI
O
N D
A
TE
R
EV
IS
ED
IA
W A
M
EN
D M
EN
T
/2
7/
PLAN
SEE SCHEDULE
FTG SIZE & REINF
ISOLATION JT
JOINT FILLER
CIRCULAR JT (OPT)
STL PIPE COL
FILL W/CONC
AFTER STEEL IS
ERECTED
CLJ
DIAMOND-SHAPED
OR CIRCULAR
ISOLATION JOINT FIN. FL EL
SEE STL COL BP
DETAIL FOR ADDITIONAL
INFORMATION
SEE PLAN FOR FTG
MARK AND TOP
OF FTG EL
1/8" DEEP MIN
2" CLR, TYP
1/8" MIN
T/
M
IN
T/
SEAL IF SLAB IS EXPOSED
SMOOTH DOWELS, COATED TO PREVENT BOND,
3/4"X1'-4"@12-5" SLAB
1"X1'-6"@12-10" SLAB
NOTES:
1. SEE FOUNDATION PLAN FOR SLAB THICKNESS.
2. SEE TYPICAL SLAB-ON-GRADE DETAIL THIS SHEET FOR SLAB DETAILS
NOT SHOWN.
XX X X X X X
1/8" DEEP MIN
1/8" MIN
T/
4 SEAL IF SLAB IS EXPOSEDWWF
CUT ALT WWF
STRANDS @ JOINT
NOTES:
1. SEE FOUNDATION PLAN FOR SLAB THICKNESS.
2. SEE TYPICAL SLAB-ON-GRADE DETAIL THIS SHEET, FOR SLAB DETAILS
NOT SHOWN.
3. IF FORMED JOINT IS USED INSERT 1/8" PREMOLDED OR METAL STRIPS WHEN
CONCRETE IS PLACED IF SAWED JOINT IS USED, SEAL IF SLAB IS EXPOSED.
MIN
2", TYP
1'-0" 2-#4 CONT
NOTES:
1. SEE FOUNDATION PLAN FOR SLAB THICKNESS.
2. THICKEN SLAB UNDER ALL INTERIOR CMU PARTITIONS EXCEEDING 8'-0" IN LENGTH.
3. SEE TYPICAL SLAB-ON-GRADE DETAIL THIS SHEET, FOR SLAB DETAILS NOT SHOWN.
4. AT LOAD BEARING WALL THE THICKENED SLAB WIDTH SHALL BE 3'-0" AND THE REINF
WILL BE 5-#4.
CMU WALL REINF
SEE 4/S-503, UNO.
1/
2" C
LR
4" T
GRANULAR FILLVAPOR RETARDERWWF
NOTES:
1. SEE FOUNDATION PLAN FOR SLAB THICKNESS.
2. SEE CONCRETE NOTES FOR REINFORCEMENT REQUIREMENTS.
3. PROVIDE CHAIRS TO SUPPORT WWF AT SPECIFIED ELEVATION.
1'-0" 1'-0"
3" C
LR
8"
STRINGER
2-#4 CONT
#4@12 OC
NOTES:
1. SEE FOUNDATION PLAN FOR SLAB THICKNESS.
2. SEE TYPICAL SLAB-ON-GRADE DETAIL THIS SHEET,
FOR SLAB DETAILS NOT SHOWN.
FIN. GR
SEE CIVIL DRAWINGS FOR
ELEVATION AND LOCATION
EQUIPMENT FACE MIN
M
IN
1' -6
1'-0"
6"
2-#5
#4@12 EW
6"
2" C
LR
TO SUIT EQPT
PROVIDED (6" MIN)
#3@12EW
#3@24
(4 SIDES)
NOTES:
1. AT CONTRACTOR'S OPTION, DOWELS MAY BE INSTALLED
BY DRILLING AND GROUTING AFTER SLAB IS PLACED.
2. FOR 15" AND 19" EQUIPMENT PAD PROVIDE 2 LAYERS OF #3@12 EW.
MIN
EQUIPMENT FACE
6"
NOTE 2
8"
C O
O R
D W
EL
EV
AT
O R
P R
O
VI
D
ED
3" CLR TYP
3"
8"
8"
(x1'-6")
4' -0
1' -0
6"
6"
1' -0
1'
-6
1'-6" 6"
CLR
3"
CLR
TYP
SEE PLAN
2'-0"
2"2"
#4@12 EW, T&B
#4@12 EW, TYP #4@12 EW
#4@12 EW, T&B
WWF
FIN. FL EL.
#4@12 WWF
LA
PS
P
LI
C E, T
YP
W-19-4 (1X1/8)
STEEL GRATING WSWS
3" C
LR
2'-6"
2' -0
1'-0"
JOINT FILLER
2-#5 CONT
SEALANT
EDGE CORNER
TO 1/8" RADIUS
FIN FL
EL CONC WALK
WWF
#4@18
#5 CONT
NOTES:
1. SEE ARCH. DWGS FOR LOCATION AND DEPTH OF SLAB
DEPRESSION.
2. SEE TYPICAL SLAB-ON-GRADE DETAIL THIS SHEET, FOR
SLAB DETAILS NOT SHOWN.
3. SEE FOUNDATION PLAN FOR SLAB THICKNESS.
VARIES
8"
WWF 1-#4
2'-0" 2'-0"
S>3D
T
#4@18
D h h
NOTES:
1. SLAB REINF NOT SHOWN FOR CLARITY. PROVIDE REINF SHOWN
IN ADDITION TO SLAB REINF.
2. D < T/3
3. h= T/3 (MIN)
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
-D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
C
AT
EG
O
R Y
C O
D E
1 2 3 4 5
A
M O
O D
Y
AF
B, G
A M
O O
D Y
AF
B
H
AN
G A
R /H
M U
SA
VA
N N
AH
D
IS
TR
IC
T
SA
VA
N N
A H
, G
EO
R G
IA
AE
C
O M
S
ER
VI
C
E S, IN
C
S J
EF
FE
R
SO
N S
T
ST
E
R
O
AN
O
KE
V A
1-
JU
LY
2, 7 8 9 10
B
C
D
E
F
G
C S
R
1-
5-
W
2H N
-1 9-
R -3
ISSUED FOR CONSTRUCTION
S-501
TY
PI
C
AL
D
ET
AI
LS
BS
B
M W
R
H M
F
NOT TO SCALES-501
TYPICAL INTERIOR TUBE
COLUMN FOOTING DETAIL
NOT TO SCALES-501
2 CONSTRUCTION JOINT
NOT TO SCALES-501
3 CONTROL JOINT
NOT TO SCALES-501
TYPICAL SLAB DETAIL AT INTERIOR
NON-LOAD BEARING WALL
NOT TO SCALES-501
5 TYPICAL SLAB-ON-GRADE
NOT TO SCALES-501
THICKENED SLAB
AT STAIR STRINGER
NOT TO SCALES-501
TYPICAL EXTERIOR
EQUIPMENT PAD DETAIL
NOT TO SCALES-501
8 EQUIPMENT PAD DETAIL
NOT TO SCALES-501
10 ELEVATOR PIT DETAIL
NOT TO SCALES-501
9 TURNED DOWN SLAB EDGE AT DOORS
NOT TO SCALES-501
11 TYPICAL SLAB DEPRESSION
NOT TO SCALES-501
TYPICAL CONDUIT PLACEMENT
FOR SLABS ON GRADE
M
AR
K D
E
SC
R
IP
TI
O
N D
A
TE
R
EV
IS
ED
IA
W A
M
EN
D M
EN
T
/2
7/
110 SF
VEST.
210 SF
OFFICE
44 SF
FA/CATV
46 SF
ELEV CNTRL
1,124 SF
READY
BRIEFING
RM
669 SF
CORR
303 SF
FP ROOM
1SA
105 108B 2SA
4C
8A
114D
A B C D E F G H I
MATCH LINE SEE A-101B
MATCH LINE SEE A-101D
M O
3' -4
5'
-4
5' -4
M
.O
3' -4
5.01
UP
UP
50 SF
ELEV.
E1
UP
LINE OF MEZZANINE
ABV, SEE SHEET A-101E
FD
FD
7' -0
114B
22.02
5.08
22.03 8.04
'-8
'-1
C.2 F.7E.7
21'-11" 21'-9" 7'-1" 14'-8" 21'-9" 17'-4" 4'-5" 15'-1" 6'-8" 21'-9" 22'-5"
15'-1" 23'-11 1/8" 10'-7" 16'-5 1/2" 22'-5" 8'-0" 28'-8" 27'-3 1/2" 22'-5"
9A
2A
4A
4A
555 SF
MEN'S LKR
286 SF
SECURE
STOR.
175 SF
CORR
1SB
351 SF
WOMEN
198 SF
CTK OFFICE
453 SF
DEBRIEF
180 SF
LEAD PROD
285 SF
PRODUCTION
376 SF
BREAK RM.
153 SF
SECURE
STORAGE
153 SF
COMM
81 SF
JAN
267 SF
MEN'S TLT
132A
6' -1
1/
2"
A-411
A-401
A-412
CTK WORK
AREA
102A 102B
P22A
P22A
P61A
P61A
P61A
P61A
P61A
P61
P61
P71A
P71B
P71AP71A
P61A P71 P61A
P21A
P23A
P21A
P61
P71A
P71A
P71A
P21AP61A
P71
P71
P23A
P23A
P21A
P21A
P22A
P22A P22A P22A
P21A
P61
P21AP21A
P12P12 P12
P71A
P71A
P71AP71A
P71A
P21A P21A
P12
P12
P12
P12
P71B
P71B
P12 P61A
P71A
P61A
P21A
P71A
157 SF
VEST.
109A
4F
66 SF
VEST.
114A
P71A
P21A
1S C 10
55 SF
VEST.
104A
69 SF
VEST.
112A
208 SF
STAIR-1
S1
4' -8
6'
-0
474 SF
CORR
7' -0
7' -7
/4
'-1
/8
'-8
8.08
4' -8
3'
-4
2" E
J 1'
-3
/8
5' -0
" 8' -0
6' -0
6' -4
8'
-0
'-0
4'
-0
3' -4
6'
-8
'-0
'-8
M .O
3'
-4
6' -0
2" E
J
SEE SHEET A-401
FOR LOCKER LAYOUT
8.07
10 DOUBLE TIER
LOCKERS
A-313
H.5
4E
492 SF
CORR
6'-6"
'-0
'-5
/4
'-1
3/
4"
10'-3 1/4"
18'-9 7/8"
42" H COUNTER
42" H COUNTER,
SEE INTERIOR
DRAWINGS, TYP
LASER CUTTER
BY OWNER
TYP
DN
PLATFORM
ABOVE
PLATFORM
ABOVE
LADDER TO
PLATFORM
LADDER TO
PLATFORM
CORR
EMER
EYEWASH
P12
P12
REF
W3
P71A
2S B
42" H COUNTER,
OPEN BENEATH,
SEE 7/IN401, SIM
W1
W1
A-4132
A0
22.02 22.02
W1
5.11 TYP
SEE NOTE 1
A-314
SEE NOTE 2 SEE NOTE 2
SEE NOTE 2
47'-3 3/8"
10'-6 1/2" 1'-9" 5'-7"
3' -8
3'-2" 8'-0"
7' -8
MOBILE SHELVING
UNITBY USER, NIC
RECYCLE ALCOVE,
BINS BY OWNER
10.01
6'-0"3'-4" 20'-0" 3'-4" 23'-4"2'-0"
1'-3"
6'-4"32'-0" 3'-4"22'-8" 6'-0"11'-8" 6'-4"3'-4" 3'-4"20'-8" 2'-0" 1'-3"
9'-1"
8' -5
8' -4
A-313
OPP
7'-6"
1' -3
2' -2
9'-6"
1'-6"
5' -8
5'
-8
A-203
SEE NOTE 3
THIS SHEET
SEE NOTE 4
THIS SHEET
15'-10"14'-8"33'-5"
8' -4
P12 TYP
15'-10" 8'-8"
5' -0
16'-0"109B
6'-4"
2'-0"
P71B
P71B
P71A
8'-7 5/8"
A-411
SimOPP/SIM
A. REFER TO SHEET G-003 FOR ABBREVIATIONS.
B. REFER TO SHEET A-001 FOR GENERAL NOTES,
LEGENDS AND SYMBOLS.
C. REFER TO STRUCTURAL, MECHANICAL, PLUMBING, FIRE
PROTECTION, TELECOM AND ELECTRICAL DRAWINGS
AND SPECIFICATIONS FOR ADDITIONAL WORK AND
COORDINATE EXTENT WITH RESPECTIVE TRADES.
D. ALL DIMENSIONS ARE TO FINISH FACE OF INTERIOR
PARTITIONS, COLUMN CENTERLINE OR FACE OF ROUGH
OPENING UNO.
E. PROVIDE SOLID FRT WD BLOCKING OR METAL
STRAPPING AT PARTITIONS AS REQUIRED TO
ACCOMMODATE INSTALLATION OF CASEWORK,
LOCKERS, GRAB BARS, AV EQUIPMENT, SIGNAGE AND
ALL SCHEDULED EQUIPMENT AND ACCESSORIES.
F. FIRE RATED PARTITIONS ARE NOTED BY PARTITION
TYPE. SEE SHEET A-601 FOR PARTITION TYPES.
G. ALL INTERIOR MASONRY WALLS TO RECEIVE BLOCK
FILLER AND PNT. TYP.
GENERAL NOTES THIS SHEET:
8' 4' 0 8' 16' 1/8"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
-D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
C
AT
EG
O
R Y
C O
D E:
1 2 3 4 5
A
GRAPHIC SCALES
M O
O D
Y
AF
B, G
A M
O O
D Y
AF
B
H
AN
G A
R /H
M U
SA
VA
N N
AH
D
IS
TR
IC
T
SA
VA
N N
AH
, G
EO
R
G
IA
AE
C
O M
S
ER
VI
C
E S, IN
C
S J
EF
FE
R
SO
N S
T
ST
E
R
O
AN
O
KE
V A
-1
JU
LY
2, 7 8 9 10
B
C
D
E
F
G
C S
R
N
1-
5-
W
2H N
-2 0-
B-
KEYPLAN
A
B
C
D
ISSUED FOR CONSTRUCTION
A-101C
FI
R
ST
F
LO
O
R P
LA
N
-A R
EA
C
H
AN
G
AR
H M
U
R
BT
JB
H
M
AC
1/8" = 1'-0"
FIRST FLOOR PLAN - AREA C - HANGAR / HMU
SHEET KEYNOTES:
5.01 PREENGINEERED METAL BUILDING COLUMN,
SEE STRUCTURAL
5.08 METAL PAN STAIR WITH CONCRETE FILL
5.11 6" DIA PAINTED GALV STL PIPE BOLLARD WITH
CONC FILL & DOMED CAP
8.04 INSULATED OVERHEAD COILING METAL DOOR
8.07 FIRE RATED WINDOWS WITH PAINTED HM
FRAMES & CLEAR FIRE RATED GLASS
8.08 FIRE RATED COILING…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .