W912HN-21-B-3008_DRAWINGS_VOL1E.pdf

PDF 3 MB Posted

Attached to
PN ST-22018-8P Vincent Hall Renovation, Phase 1, Fort Gordon, GA
Solicitation number
W912HN21B3008
Issued by

About this file

This is an invitation for bid for construction services. The solicitation seeks bids for Phase 1 of the Vincent Hall Renovation project at Fort Gordon, Georgia, which includes 56,555 square feet of interior renovation work as well as associated mechanical, electrical, elevator, fire alarm, and sprinkler infrastructure to support both phases of construction. The project falls under NAICS code 236220 with an estimated value between $10 million and $25 million. Bids are due in accordance with the solicitation number W912HN21B3008. The Army Corps of Engineers is the contracting agency. A price evaluation preference will be applied to eligible HUBZone small businesses. The solicitation package includes eight specifications and drawing files in addition to the base solicitation document.

View the file

Other files

File Type Posted
C.04. W912HN21B3008 - Vincent Hall Reno. -HUB zone preference ABSTRACT.pdf PDF
W912HN21B3008 BID OPENING ATTENDEES.pdf PDF
C.04. W912HN21B3008 - Vincent Hall Reno. -HUB zone preference.pdf PDF
W912HN-21-B-3008_DRAWINGS_VOL1A_AMD2.pdf PDF
W912HN-21-B-3008_DRAWINGS_VOL1D_AMD2.pdf PDF
B.08 W912HN21B3008 Amendment 0002.pdf PDF
B.08 W912HN21B3008 Amendment 0002 CC.pdf PDF
W912HN-21-B-3008_DRAWINGS_VOL1A_AMD1.pdf PDF
W912HN-21-B-3008_DRAWINGS_VOL1B_AMD1.pdf PDF
B.08 W912HN21B3008 Amendment 0001.pdf PDF
Phase1_RTA_V2-C_Div_25-33_Appendices_AMD1.pdf PDF
W912HN-21-B-3008_DRAWINGS_VOL1C_AMD1.pdf PDF
Phase1_RTA_V2-A_Div_00-07_AMD1.pdf PDF
W912HN-21-B-3008_DRAWINGS_VOL1D_AMD1.pdf PDF
Phase1_RTA_V2-B_Div_08-23_AMD1.pdf PDF
B.08 W912HN21B3008 Amendment 0001 CC.pdf PDF
Vincent Hall Site Visit Attendance Roster.pdf PDF
Vincent Hall Pre-Bid Site Visit Synopsis.docx DOCX document
B.08 - Solicitation W912HN21B3008 - Vincent Hall.pdf PDF
Phase1_RTA_V2-A_Div_00-07.pdf PDF
W912HN-21-B-3008_DRAWINGS_VOL1C.pdf PDF
Phase1_RTA_V2-B_Div_08-23.pdf PDF
W912HN-21-B-3008_DRAWINGS_VOL1A.pdf PDF
W912HN-21-B-3008_DRAWINGS_VOL1D.pdf PDF
W912HN-21-B-3008_DRAWINGS_VOL1B.pdf PDF
B.08_W912HN20B3008 Vincent Hall Solicitation.pdf PDF
Phase1_RTA_V2-C_Div_25-33 Appendices.pdf PDF
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

US Army Corps of Engineers ®

G

2 3 4 6 7 8 9 10

F

E

D

C

B

A

D A

T E

US Army Corps of Engineers ®

SOLICITATION NO.:

CONTRACT NO.:

ISSUE DATE:

VOLUME:

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

HDR Architecture

3001 WASHINGTON BLVD., SUITE 200

ARLINGTON, VIRGINIA 22201

(703)518-8500

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

SAVANNAH DISTRICT

VHALL

J U

N E

W H

N B

-- 1 -3

-0

READY TO ADVERTISE (RTA)

V

IN

C E

N T

H A

L L R

E N

O V

A T

IO

N

P H

A S

E

JUNE 2021

W912HN21B3008

VINCENT HALL RENOVATION PHASE 1

C:\rvt\2019\10053876-A-VHALL-Central_hdr-alx-rcruz.rvt

7/8/2021 10:45:35 AM

FORT GORDON, GEORGIA

FY20 PN 92894

GI041-P1

G E

N E

R A

L

C O

V E

R S

H E

E T

B

ID

A

L T

E R

N A

T E

F O

R T

G O

R D

O N

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E N

U E

S A

V A

N N

A H

G

A

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

N T

R A

N

R C

R U

Z

T M

A H

E R

H E

Z Z

E D

D

IN

E

C A

T E

G O

R Y

C O

D E

F Y

P

N

1296 Broad Street | Augusta, GA 30901 | (706) 724-5756

T E C H N O L O G I E S 10440 Little Patuxent Parkway, Suite 900 | Columbia, MD 21044 | (443) 832-3308

10280 Old Columbia Road | Columbia, MD 21046 | (410) 290-9301

1E

US Army Corps of Engineers ®

G

2 3 4 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

VHALL

J U

N E

W H

N B

-- 1 -3

-0

READY TO ADVERTISE (RTA)

V

IN

C E

N T

H A

L L R

E N

O V

A T

IO

N

P H

A S

E

C:\rvt\2019\10053876-A-VHALL-Central_hdr-alx-rcruz.rvt

7/8/2021 3:17:20 PM

GI042-P1

G E

N E

R A

L

IN

D

E X

O F

D R

A W

IN

G

S

B

ID

A L T

E R

N A

T E

F O

R T

G O

R D

O N

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E N

U E

S A

V A

N N

A H

G

A

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

N T

R A

N

R C

R U

Z

T M

A H

E R

H E

Z Z

E D

D

IN

E

C A

T E

G O

R Y

C O

D E

F Y

P

N

EL704C-P1 ELECTRICAL - LIGHTING PLAN - LEVEL 2 - AREA C - PHASE 1 - ALT #1

EL704B-P1 ELECTRICAL - LIGHTING PLAN - LEVEL 2 - AREA B - PHASE 1 - ALT #1

ELECTRICAL

A-705-P1 ARCHITECTURAL - UPFOLDING PARTITION DETAILS - PHASE 1 - BID ALT #1

A-704C-P1 ARCHITECTURAL - REFLECTED CEILING PLAN - LEVEL 2, AREA C - PHASE 1 - BID ALT #1

A-704B-P1 ARCHITECTURAL - REFLECTED CEILING PLAN - LEVEL 2, AREA B - PHASE 1 - BID ALT #1

A-702C-P1 ARCHITECTURAL - FLOOR PLAN - LEVEL 2, AREA C - PHASE 1 - BID ALT #1

A-702B-P1 ARCHITECTURAL - FLOOR PLAN - LEVEL 2, AREA B - PHASE 1 - BID ALT #1

ARCHITECTURE

S-710-P1 STRUCTURAL - STEEL - TYPICAL DETAILS - BID ALT #1

SF703C-P1 STRUCTURAL - FRAMING PLAN - ROOF, AREA C - PHASE 1 - BID ALT #1

SF703B-P1 STRUCTURAL - FRAMING PLAN - ROOF, AREA B - PHASE 1 - BID ALT #1

STRUCTURAL

GI042-P1 GENERAL - INDEX OF DRAWINGS - BID ALTERNATE

GI041-P1 GENERAL - COVER SHEET - BID ALTERNATE

GENERAL - VOLUME 1E - BID ALTERNATE

Sheet ID Drawing Title

Vincent Hall Drawing Index

E F G H J K L

2A

6A

(EX) 18H6

(EX) 18H6

(EX) 18H6

30'-6" 30'-6" 12'-0" 1'-5" 29'-1" 30'-6"

9' -8

'-0

'-0

'-0

'-1

0"

'-3

M A

T C

H

LI

N E

S

E E

:S F

3C

-P

(E X

W

X

(E X

W

X

(E X

W

X

W8X31 (B/STEEL EL = 28'-11" )

A1

S-710-P1

W8X31

COLU

M N

HSS10

X3X

1/

COLU

M

N

HSS10

X3X

1/

E X

IS

T

R O

O F

D E

C K

A8

S-710-P1

( -2" )

( -2" )( -10" )

( -6" )(+ 0" )

(+ 0" )

US Army Corps of Engineers ®

G

2 3 4 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

VHALL

J U

N E

W H

N B

-- 1 -3

-0

READY TO ADVERTISE (RTA)

V

IN

C E

N T

H A

L L R

E N

O V

A T

IO

N

P H

A S

E

C:\rvt\2019\10053876-S-VHALL-Central_rwalker5019.rvt

7/8/2021 12:04:02 PM

SF703B-P1

S T

R U

C T

U R

A L

F R

A M

IN

G

P L A

N

R O

O F

A

R E

A B

P

H A

S E

B

ID

A L T

F O

R T

G O

R D

O N

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E N

U E

S A

V A

N N

A H

G

A

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

D L E

E C

H U

Y

D L E

E C

H U

Y

T .M

A H

E R

G K

O O

S A

U

C A

T E

G O

R Y

C O

D E

F Y

NORTH

KEY PLAN

A B C

F E D

PLAN NOTES

1. TOP OF STEEL ELEVATION = 31'-10" UNO ( + / - ) ON PLAN.

2. INDICATES SPAN DIRECTION OF

EXISTING ROOF DECK. ROOF

CONSTRUCTION IS 1 1/2" X 20 GA NARROW RIB METAL

DECK. ROOF DECK ATTACHED TO ROOF FRAMING WITH

PUDDLE WELDS @ 12" OC. SIDE LAP ATTACHMENTS ARE

AT 1/3 POINTS BETWEEN SUPPORTING MEMBERS.

EXIST ROOF

DECK

1/8" = 1'-0" A1

ROOF, AREA B - PHASE 1 - BID ALT #1

UPFOLDING

PARTITION BELOW

L M N P Q QQ

2A

6A

(EX) 18H6(EX) W14X22(EX) 18H6

(EX) 18H6 (EX) 18H6

(EX) W14X22(EX) 18H6

(EX) 18H6

(EX) 18H6

(EX) 18H6

(EX) 18H6

(EX) 18H6

9' -8

'-0

'-0

'-0

'-1

0"

'-3

30'-6" 30'-6" 30'-6" 30'-6" 9'-2"

M A

T C

H

LI

N E

S

E E

:S F

3B

-P

(E X

W

X

A1

S-710-P1

(E X

W

X

(E X

W

X

(E X

W

X

(E X

W

X

W8X31 W8X31 W8X31 W8X31(B/STEEL EL = 28'-11" ) (B/STEEL EL = 28'-11" ) (B/STEEL EL = 28'-11" ) (B/STEEL EL = 28'-11" )

COLU

M N

HSS10

X3X

1/

COLU

M

N

HSS10

X3X

1/

COLU

M

N

HSS10

X3X

1/

COLU

M

N

HSS10

X3X

1/

E X

IS

T

R O

O F

D E

C K

A8

S-710-P1

TYP

( -2" )

( -2" ) ( -10" )

( -6" ) ( -2" )

( -2" ) ( -10" )

( -6" ) (+ 0" )

(+ 0" )

US Army Corps of Engineers ®

G

2 3 4 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

VHALL

J U

N E

W H

N B

-- 1 -3

-0

READY TO ADVERTISE (RTA)

V

IN

C E

N T

H A

L L R

E N

O V

A T

IO

N

P H

A S

E

C:\rvt\2019\10053876-S-VHALL-Central_rwalker5019.rvt

7/8/2021 12:04:06 PM

SF703C-P1

S T

R U

C T

U R

A L

F R

A M

IN

G

P L A

N

R O

O F

A

R E

A C

P

H A

S E

B

ID

A L T

F O

R T

G O

R D

O N

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E N

U E

S A

V A

N N

A H

G

A

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

D L E

E C

H U

Y

D L E

E C

H U

Y

T .M

A H

E R

G K

O O

S A

U

C A

T E

G O

R Y

C O

D E

F Y

NORTH

KEY PLAN

A B C

F E D

PLAN NOTES

1. TOP OF STEEL ELEVATION = 31'-10" UNO ( + / - ) ON PLAN.

2. INDICATES SPAN DIRECTION OF

EXISTING ROOF DECK. ROOF

CONSTRUCTION IS 1 1/2" X 20 GA NARROW RIB METAL

DECK. ROOF DECK ATTACHED TO ROOF FRAMING WITH

PUDDLE WELDS @ 12" OC. SIDE LAP ATTACHMENTS ARE

AT 1/3 POINTS BETWEEN SUPPORTING MEMBERS.

EXIST ROOF

DECK

1/8" = 1'-0" A1

ROOF, AREA C - PHASE 1 - BID ALT #1

B/STEEL

EL SEE PLAN

LEVEL 2

TOP OF CONC

B/STEEL

EL SEE PLAN

BOTTOM OF BEAM

EL SEE PLAN

EL SEE PLAN

EXISTING ROOF STRUCTURE

EXISTING OPEN

WEB JOIST, TYP.

BRACING, ALIGN WITH

HANGER AND MOTOR

SEE

SIMILAR.

PARTITION HANGER OR

PARTITION MOTOR, BY

MANUFACTURER

T/STEEL

VARIES

/F1 S-522-P1

PL 3/8 FULL DEPTH

T/EXIST FLOOR

HSS10X3X1/4 POST

EXISTING

ROOF JOIST

WIDE FLANGE FOLDING

PARTITION SUPPORT

WHERE SHOWN ON PLAN

BEAM, SEE PLAN

EXISTING

ROOF JOIST

UPFOLDING PARTITION

CONNECTION BY PARTITION

MANUFACTURER

EXIST BEAM

SEE PLAN

INTERIOR WALL,

SEE ARCH DWGS.

L4X4X1/4 x 0'-3" LONG

WITH (1) 1/2"Ø MECHANICAL

ANCHOR x 2" MIN EFFECTIVE

EMBEDMENT, EACH SIDE

HSS10X3 POST

3/16

TYP

CLEAR

1/2"

L6X4X1/2 x 0'-8" (LLV)

L4X4X1/4 x 0'-8" LONG WITH 1/2"Ø THREADED ROD

IN VERTICALLY LONG SLOTTED HOLES. FINGER

TIGHTEN AND SEVER THREADS. INSTALL ROD IN

MIDDLE OF SLOTTED HOLE

C

LE

A R

1" 3/16

TYP

EXIST ROOF BEAM

3/16

TYP

SECTION A-A

A A

A4

S-710-P1

SEE SF-102 SHEETS

MAX.

3"

EXIST ROOF DECK

3/16 3"

3/16

L4X4X3/8 x 0'-4"

3/8 PARTIAL DEPTH

STIFFENER, EA SIDE.

STOP AT BEAM 'K'

DIMENSION .

1/4

TYPK

BEAM,

SEE PLAN

EXIST JOIST

SEE PLAN

EXIST BEAM,

SEE PLAN

L3X3X3/8 x 0'-8" LONG

ALIGN VERTICAL LEG

WITH EXIST BEAM WEB

PL 3/8X6

(2) 3/4"Ø BOLTS

@ 3" O.C.

3/16

3/16

PARTITION HANGER

BY PARTITION MANUF.

3/8 FULL DEPTH

STIFF, EA SIDE

3/8 FULL DEPTH

STIFFENER, ONE SIDE

1/4

3 SIDES

US Army Corps of Engineers ®

G

2 3 4 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

VHALL

J U

N E

W H

N B

-- 1 -3

-0

READY TO ADVERTISE (RTA)

V

IN

C E

N T

H A

L L R

E N

O V

A T

IO

N

P H

A S

E

C:\rvt\2019\10053876-S-VHALL-Central_rwalker5019.rvt

7/8/2021 12:01:55 PM

S-710-P1

S T

R U

C T

U R

A L

S T

E E

L

T Y

P

IC

A L D

E T

A

IL

S

P

H A

S E

B

ID

A L T

F O

R T

G O

R D

O N

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E N

U E

S A

V A

N N

A H

G

A

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

D L E

E C

H U

Y

D L E

E C

H U

Y

T M

A H

E R

G K

O O

S A

U

C A

T E

G O

R Y

C O

D E

F Y

1" = 1'-0" A4

PARTITION LATERAL BRACE

1" = 1'-0"

A8

PARTITION LATERAL SUPPORT

1" = 1'-0"

BRACING DETAIL

DN

E F G H J K L

LEARNING

ENVIRONMENT

20152015

INSTRUCTOR

20252025

ASI1C

LAB/

EQUIPMENT

20372037

LEARNING

ENVIRONMENT

20272027

LEARNING

ENVIRONMENT

20382038

25D LAB

259259

BREAK

ROOM

261261

STORAGE

260260

VAULT

247247

VAULT

265265

MAINTENANCE

248248

MAINTENANCE

249249

STAIR 1

21012101

25P

STORAGE

250B250B

25P TCF

CLASSRM

251A251A

25P

STORAGE/

ADMIN

250A250A

LOBBY

201201

INSTRUCTOR

20142014

CORRIDOR

262262

CORRIDOR

244244

CORRIDOR

23042304

CORRIDOR

263263

CORRIDOR

23052305

M A

T C

H L

IN

E

S

E E

A

-7

C

-P

ELEV #1

ELV01ELV01

WORK/

COPY

2014A2014A

UPFOLDING PANEL PARTITION

A7

A-705-P1

TYP

SUMMARY - BID ALTERNATE #1

THIS ALTERNATE INCLUDES (5) UPFOLDING PARTITIONS

WHICH ALLOW TWO ADJACENT LEARNING

ENVIRONMENTS TO BE COMBINED INTO ONE LARGER

SPACE.

REFER TO SPECIFICATION 10 22 29 UPFOLDING PANEL

PARTITIONS.

IT IMPACTS (10) OF THE LEARNING ENVIRONMENTS,

WITH THE NEW UPFOLDING PARTITIONS REPLACING

THE ROOM'S BASE BID D3 PARTITION BETWEEN

GRIDLINE 4 AND 5.

ALL PERIMETER LIGHTING THAT WAS LOCATED ALONG

THE REPLACED BASE BID'S D3 PARTITION IS REMOVED

IN THIS ALTERNATE.

IMPACTED ROOMS INCLUDE:

LEVEL TWO: 2027 & 2038; 2029 & 2036; 2030 & 2035; 2031

& 2034; 2032 & 2033

IMPACTS TO ARCHITECTURE AND LIGHTING ARE

INDICATED ON FLOOR PLANS.

IMPACTED AREAS ARE AS INDICATED

US Army Corps of Engineers ®

G

2 3 4 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

VHALL

J U

N E

W H

N B

-- 1 -3

-0

READY TO ADVERTISE (RTA)

V

IN

C E

N T

H A

L L R

E N

O V

A T

IO

N

P H

A S

E

C:\rvt\2019\10053876-A-VHALL-Central_nhu.tran@hdrinc.com.rvt

7/7/2021 1:50:45 PM

A-702B-P1

A R

C H

IT

E

C T

U R

A L

F L O

O R

P L A

N

L E

V E

L

A

R E

A B

P

H A

S E

B

ID

A L T

F O

R T

G O

R D

O N

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E N

U E

S A

V A

N N

A H

G

A

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

N T

R A

N

R C

R U

Z

T M

A H

E R

H E

Z Z

E D

D

IN

E

C A

T E

G O

R Y

C O

D E

F Y

P

N

NORTH

KEY PLAN

A B C

F E D

8'4' 16'0

SCALE: 1/8"=1'-0"

1/8" = 1'-0"

LEVEL 2 - AREA B - PHASE 1 BID ALTERNATE #1

L M N P Q

LEARNING

ENVIRONMENT

20192019

LEARNING

ENVIRONMENT

20182018

LEARNING

ENVIRONMENT

20172017

LEARNING

ENVIRONMENT

20162016

INSTRUCT

STORAGE

20242024

TELECOM

20212021

ELEC

20222022

ELEV #2

22022202

CAVE

20202020

LEARNING

ENVIRONMENT

20322032

LEARNING

ENVIRONMENT

20332033

LEARNING

ENVIRONMENT

20312031

LEARNING

ENVIRONMENT

20342034

LEARNING

ENVIRONMENT

20302030

LEARNING

ENVIRONMENT

20352035

LEARNING

ENVIRONMENT

20292029

LEARNING

ENVIRONMENT

20362036

BALCONY

N/AN/A

STAIR 3

21032103

INSTRUCTOR

20252025

WORK/

COPY

2025A2025A

CORRIDOR

23042304

CORRIDOR

23052305

UPFOLDING PANEL PARTITION UPFOLDING PANEL PARTITION UPFOLDING PANEL PARTITION

M A

T C

H L

IN

E

S

E E

A

-7

B

-P

UPFOLDING PANEL PARTITION

A7

A-705-P1TYP

SUMMARY - BID ALTERNATE #1

THIS ALTERNATE INCLUDES (5) UPFOLDING PARTITIONS

WHICH ALLOW TWO ADJACENT LEARNING

ENVIRONMENTS TO BE COMBINED INTO ONE LARGER

SPACE.

REFER TO SPECIFICATION 10 22 29 UPFOLDING PANEL

PARTITIONS.

IT IMPACTS (10) OF THE LEARNING ENVIRONMENTS,

WITH THE NEW UPFOLDING PARTITIONS REPLACING

THE ROOM'S BASE BID D3 PARTITION BETWEEN

GRIDLINE 4 AND 5.

ALL PERIMETER LIGHTING THAT WAS LOCATED ALONG

THE REPLACED BASE BID'S D3 PARTITION IS REMOVED

IN THIS ALTERNATE.

IMPACTED ROOMS INCLUDE:

LEVEL TWO: 2027 & 2038; 2029 & 2036; 2030 & 2035; 2031

& 2034; 2032 & 2033

IMPACTS TO ARCHITECTURE AND LIGHTING ARE

INDICATED ON FLOOR PLANS.

IMPACTED AREAS ARE AS INDICATED

US Army Corps of Engineers ®

G

2 3 4 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

VHALL

J U

N E

W H

N B

-- 1 -3

-0

READY TO ADVERTISE (RTA)

V

IN

C E

N T

H A

L L R

E N

O V

A T

IO

N

P H

A S

E

C:\rvt\2019\10053876-A-VHALL-Central_nhu.tran@hdrinc.com.rvt

7/7/2021 1:50:46 PM

A-702C-P1

A R

C H

IT

E

C T

U R

A L

F L O

O R

P L A

N

L E

V E

L

A

R E

A C

P

H A

S E

B

ID

A L T

F O

R T

G O

R D

O N

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E N

U E

S A

V A

N N

A H

G

A

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

N T

R A

N

R C

R U

Z

T M

A H

E R

H E

Z Z

E D

D

IN

E

C A

T E

G O

R Y

C O

D E

F Y

P

N

NORTH

KEY PLAN

A B C

F E D

8'4' 16'0

SCALE: 1/8"=1'-0"

1/8" = 1'-0"

LEVEL 2 - AREA C - PHASE 1 BID ALTERNATE #1

E F G H J K L

INSTRUCTOR

20142014

STAIR 1

21012101

LEARNING

ENVIRONMENT

20272027

ASI1C

LAB/

EQUIPMENT

20372037

INSTRUCTOR

20252025

CORRIDOR

23052305

LEARNING

ENVIRONMENT

20152015

CORRIDOR

23042304

INSTRUCTOR

20252025

LEARNING

ENVIRONMENT

20382038

LOBBY

201201

STORAGE

260260

BREAK

ROOM

261261

25D LAB

259259

VAULT

247247

MAINTENANCE

248248

25P

STORAGE

250B250B

25P

STORAGE/

ADMIN

250A250A

C7

A-705-P1

M A

T C

H

LI

N E

S

E E

: A -7

C

-P

REFLECTED CEILING PLAN LEGEND

LINEAR LIGHT FIXTURE

LINEAR PENDANT LIGHT FIXTURE

DOWN LIGHT FIXTURE

EXIT SIGN

SPEAKER

ACOUSTICAL CEILING TILE SIZE VARIES

REFER TO A-140 DRAWING SERIES

GYPSUM BOARD CEILING

EXPOSED

NOT IN SCOPE

CEILING HEIGHT TAG

EMERGENCY LIGHT

EXTERIOR WALL LIGHT

EXHAUST GRILLE

DIFFUSER

EXISTING FIXTURE

US Army Corps of Engineers ®

G

2 3 4 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

VHALL

J U

N E

W H

N B

-- 1 -3

-0

READY TO ADVERTISE (RTA)

V

IN

C E

N T

H A

L L R

E N

O V

A T

IO

N

P H

A S

E

C:\rvt\2019\10053876-A-VHALL-Central_hdr-alx-rcruz.rvt

7/7/2021 12:40:05 PM

A-704B-P1

A R

C H

IT

E

C T

U R

A L

R E

F L E

C T

E D

C E

IL

IN

G P

L A

N

L E

V E

L

A

R E

A B

P

H A

S E

B

ID

A L T

F O

R T

G O

R D

O N

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E N

U E

S A

V A

N N

A H

G

A

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

N T

R A

N

C N

O R

T H

C U

T T

T M

A H

E R

H E

Z Z

E D

D

IN

E

C A

T E

G O

R Y

C O

D E

F Y

P

N

NORTH

KEY PLAN

A B C

F E D

8'4' 16'0

SCALE: 1/8"=1'-0"

1/8" = 1'-0" A1

RCP LEVEL 2 - AREA B - PHASE 1 BID ALT #1 P1

14. ALL MECHANICAL EQUIPMENT AND LIGHT FIXTURES IN

EXPOSED AND GWB CEILINGS SHALL BE CENTERED AND

EQUALLY SPACED ON EXTENTS UNLESS NOTED

OTHERWISE.

13. ALL MECHANICAL EQUIPMENT AND LIGHT FIXTURES IN

EXPOSED CEILINGS SHALL BE 10'-0" AFF UNLESS NOTED

OTHERWISE.

12. FOR ALL ACT CEILINGS THAT MEET AN EXPOSED

STRUCTURAL COLUMN END CEILING 1" FROM THE FACE OF

FLANGES WITH SCHEDULED WALL ANGLE.

11. ALIGN BULKHEADS WITH COLUMN FURRINGS OR EDGES,

UNLESS NOTED OTHERWISE.

10. FOR ALL SUSPENDED CEILING ELEMENTS THAT DO NOT

TERMINATE AT A WALL PAINT EXPOSED CEILING ABOVE

FACE OF PERIMETER TRIM WITH PT-9 UNLESS NOTED

OTHERWISE.

9. ALL SUSPENDED ACT CEILING ELEMENTS THAT DO NOT

TERMINATE AT A WALL REFER TO F8/A-511-P1 PERIMETER

TRIM DETAILS, UNLESS NOTED OTHERWISE.

8. REFERENCE TYPICAL CEILING DETAILS FOR CEILING

PERIMETER.

7. REFER TO MILLWORK DRAWINGS AND ELECTRICAL PLANS

FOR INTEGRATED LIGHTING.

6. UNLESS NOTED OTHERWISE, ALL DIMENSIONS TO LIGHT

FIXTURES ARE TO: -FIXTURE CENTERLINES: - COLUMN

CENTERLINES: - FACE OF GWB: - FACE OF MASONRY: - FACE

OF CONCRETE.

5. CENTER CEILING LIGHTS, SPRINKLER HEADS, AND OTHER

CEILING MOUNTED DEVICES (RECESSED OR SURFACE

MOUNTING) IN CEILING TILE EXTENTS UNLESS NOTED

OTHERWISE.

4. LAY-IN CEILING PANELS SHALL NOT BE SMALLER THAN 6"

WIDE, TYPICAL.

3. CENTER CEILING TILES IN ROOM OR CENTER CEILING GRID

TO THE CENTER OF ROOM, UNLESS NOTED OTHERWISE.

2. REFER TO A-140 SERIES FOR CEILING TYPES AND FINISHES.

1. ALL CEILING HEIGHTS SHALL BE 9'-0" AFF ON LEVEL 1 AND

10'-0" AFF ON LEVEL 2 UNLESS NOTED OTHERWISE.

REFLECTED CEILING PLAN

GENERAL NOTES

L M N P Q

LEARNING

ENVIRONMENT

20312031

LEARNING

ENVIRONMENT

20322032

LEARNING

ENVIRONMENT

20332033

LEARNING

ENVIRONMENT

20342034

LEARNING

ENVIRONMENT

20302030

LEARNING

ENVIRONMENT

20352035

LEARNING

ENVIRONMENT

20292029

LEARNING

ENVIRONMENT

20362036

CORRIDOR

23042304

INSTRUCT

STORAGE

20242024

LEARNING

ENVIRONMENT

20182018

LEARNING

ENVIRONMENT

20172017

LEARNING

ENVIRONMENT

20192019

LEARNING

ENVIRONMENT

20162016

INSTRUCTOR

20252025

WORK/

COPY

2025A2025A

CORRIDOR

23052305

CONF 8-10

PN

20422042

CAVE

20402040

C7

A-705-P1

M A

T C

H

LI

N E

S

E E

: A -7

4B

-P

REFLECTED CEILING PLAN LEGEND

LINEAR LIGHT FIXTURE

LINEAR PENDANT LIGHT FIXTURE

DOWN LIGHT FIXTURE

EXIT SIGN

SPEAKER

ACOUSTICAL CEILING TILE SIZE VARIES

REFER TO A-140 DRAWING SERIES

GYPSUM BOARD CEILING

EXPOSED

NOT IN SCOPE

CEILING HEIGHT TAG

EMERGENCY LIGHT

EXTERIOR WALL LIGHT

EXHAUST GRILLE

DIFFUSER

EXISTING FIXTURE

US Army Corps of Engineers ®

G

2 3 4 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

VHALL

J U

N E

W H

N B

-- 1 -3

-0

READY TO ADVERTISE (RTA)

V

IN

C E

N T

H A

L L R

E N

O V

A T

IO

N

P H

A S

E

C:\rvt\2019\10053876-A-VHALL-Central_hdr-alx-rcruz.rvt

7/7/2021 12:40:17 PM

A-704C-P1

A R

C H

IT

E

C T

U R

A L

R E

F L E

C T

E D

C E

IL

IN

G P

L A

N

L E

V E

L

A

R E

A C

P

H A

S E

B

ID

A L T

F O

R T

G O

R D

O N

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E N

U E

S A

V A

N N

A H

G

A

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

N T

R A

N

C N

O R

T H

C U

T T

T M

A H

E R

H E

Z Z

E D

D

IN

E

C A

T E

G O

R Y

C O

D E

F Y

P

N

NORTH

KEY PLAN

A B C

F E D

8'4' 16'0

SCALE: 1/8"=1'-0"

1/8" = 1'-0" A1

RCP LEVEL 2 - AREA C - PHASE 1 BID ALT #1 P1

14. ALL MECHANICAL EQUIPMENT AND LIGHT FIXTURES IN

EXPOSED AND GWB CEILINGS SHALL BE CENTERED AND

EQUALLY SPACED ON EXTENTS UNLESS NOTED

OTHERWISE.

13. ALL MECHANICAL EQUIPMENT AND LIGHT FIXTURES IN

EXPOSED CEILINGS SHALL BE 10'-0" AFF UNLESS NOTED

OTHERWISE.

12. FOR ALL ACT CEILINGS THAT MEET AN EXPOSED

STRUCTURAL COLUMN END CEILING 1" FROM THE FACE OF

FLANGES WITH SCHEDULED WALL ANGLE.

11. ALIGN BULKHEADS WITH COLUMN FURRINGS OR EDGES,

UNLESS NOTED OTHERWISE.

10. FOR ALL SUSPENDED CEILING ELEMENTS THAT DO NOT

TERMINATE AT A WALL PAINT EXPOSED CEILING ABOVE

FACE OF PERIMETER TRIM WITH PT-9 UNLESS NOTED

OTHERWISE.

9. ALL SUSPENDED ACT CEILING ELEMENTS THAT DO NOT

TERMINATE AT A WALL REFER TO F8/A-511-P1 PERIMETER

TRIM DETAILS, UNLESS NOTED OTHERWISE.

8. REFERENCE TYPICAL CEILING DETAILS FOR CEILING

PERIMETER.

7. REFER TO MILLWORK DRAWINGS AND ELECTRICAL PLANS

FOR INTEGRATED LIGHTING.

6. UNLESS NOTED OTHERWISE, ALL DIMENSIONS TO LIGHT

FIXTURES ARE TO: -FIXTURE CENTERLINES: - COLUMN

CENTERLINES: - FACE OF GWB: - FACE OF MASONRY: - FACE

OF CONCRETE.

5. CENTER CEILING LIGHTS, SPRINKLER HEADS, AND OTHER

CEILING MOUNTED DEVICES (RECESSED OR SURFACE

MOUNTING) IN CEILING TILE EXTENTS UNLESS NOTED

OTHERWISE.

4. LAY-IN CEILING PANELS SHALL NOT BE SMALLER THAN 6"

WIDE, TYPICAL.

3. CENTER CEILING TILES IN ROOM OR CENTER CEILING GRID

TO THE CENTER OF ROOM, UNLESS NOTED OTHERWISE.

2. REFER TO A-140 SERIES FOR CEILING TYPES AND FINISHES.

1. ALL CEILING HEIGHTS SHALL BE 9'-0" AFF ON LEVEL 1 AND

10'-0" AFF ON LEVEL 2 UNLESS NOTED OTHERWISE.

REFLECTED CEILING PLAN

GENERAL NOTES

EXISTING

STRUCTURAL SLAB

5/8" GYP BD ON 3 5/8"

STUDS WITH SOUND

BATTS

ACOUSTICAL

SEALANT

RAISED ACCESS PEDESTAL

RAISED ACCESS PANEL

FINISH FLOOR

FLOOR FINISH AS SCHED

UPFOLDING PANEL PARTITION

ACOUSTIC SEALANT

RAISED ACCESS PANEL

ACOUSTIC SEALANT

TWO LAYERS

5/8" FRT

PLYWOOD

1' - 0"

5/8" GYP BD ON 3 5/8"

STUDS WITH SOUND BATTS

METAL BRACING AS REQUIRED

STEEL BEAM; RE: STRUCT

6" MTL STUDS @ 16" O.C.

COORDINATE WITH MOTOR UNIT,

LIFTING MECHANISMS AND CABLES

TO AVOID INTERFERENCE.

CLEAR

9"

EQ EQ

5' - 3 3/8"

HANGER SUPPORT BY UPFOLDING

PANEL PARTITION MANUFACTURER

ACOUSTIC BARRIER: 2 LAYERS 5/8"

GWB EACH SIDE UP TO & SEALED TO

SLAB TO MAINTAIN STC 50 RATING

FLEXIBLE ACOUSTIC CEILING SEAL

BY UPFOLDING PANEL PARTITION

MANUFACTURER

UPFOLDING PANEL PARTITION

CEILING AS SCHEDULED

B.O. STRUCTURE

12' - 7"

ACOUSTICAL CEILING TILE ONLY

2 1/2" MTL STUDS @ 16" O.C.

B.O. POCKET

10'-0" A.F.F.

T.O. POCKET

11'-6 1/2" A.F.F.

B.O. ACOUSTIC BARRIER

11'-5 1/2" A.F.F.

US Army Corps of Engineers ®

G

2 3 4 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

VHALL

J U

N E

W H

N B

-- 1 -3

-0

READY TO ADVERTISE (RTA)

V

IN

C E

N T

H A

L L R

E N

O V

A T

IO

N

P H

A S

E

C:\rvt\2019\10053876-A-VHALL-Central_hdr-alx-rcruz.rvt

7/7/2021 12:40:25 PM

A-705-P1

A R

C H

IT

E

C T

U R

A L

U P

F O

L D

IN

G

P A

R T

IT

IO

N D

E T

A

IL

S

P H

A S

E

B

ID

A

L T

F O

R T

G O

R D

O N

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E N

U E

S A

V A

N N

A H

G

A

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

N T

R A

N

C N

O R

T H

C U

T T

T M

A H

E R

H E

Z Z

E D

D

IN

E

C A

T E

G O

R Y

C O

D E

F Y

P

N

1 1/2" = 1'-0" A7

RAF - DETAIL AT UPFOLDING PANEL PARTITION

3/4" = 1'-0" C7

CEILING DETAIL @ UPFOLDING PANEL PARTITION IN LEARNING ENVIRONMENTS

OSOS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS OS

OS

OS

OS

OS

OS

OSOS

OSOS

OS

OS

OS OS

OS OS

OS OS

OS OS

OS

OS

OS

OS

OS

OS

LIGHTING GENERAL NOTES

LIGHTING KEYNOTES

A. FOR ELECTRICAL SYMBOLS AND ABBREVIATIONS REFER TO

DRAWINGS SHEET E-001-P1 AND E-002-P1.

B. ELECTRICAL WORK SHALL BE DONE IN CONFORMANCE WITH THE

CONSTRUCTION DOCUMENTS, ALL APPLICABLE CODES, ISSUED

DRAWINGS AND SPECIFICATIONS.

C. CONDUIT AND RACEWAYS SHOWN ARE DIAGRAMMATIC IN

NATURE. EXACT ROUTING AND REQUIREMENTS SHALL BE

COORDINATED WITH ALL TRADES PRIOR TO INSTALLATION.

D. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR

EXACT LOCATION OF ALL CEILING MOUNTED DEVICES.

E. COORDINATE THE INSTALLATION OF ALL RECESSED LIGHTING

LUMINARIES WITH ACTUAL CEILING TYPES. REFER TO

ARCHITECTURAL FINISH SCHEDULES FOR ADDITIONAL DETAILS.

F. COORDINATE THE INSTALLATION OF LIGHTING LUMINARIES WITH

AUDIO VISUAL SYSTEMS AND ALL OTHER TRADES. COORDINATE

EXACT LOCATION OF ALL ELECTRICAL, LOW VOLTAGE, AND

LIGHTING DEVICES WITH ARCHITECTURAL, CASEWORK (AUDIO

VISUAL SYSTEMS), AND GENERAL ELEVATIONS PRIOR TO

ROUGH-IN.

G. SUPPORT ALL RECESSED AND PENDANT MOUNTED LUMINARIES

FROM STRUCTURE IN ACCORDANCE WITH APPLICABLE BUILDING

CODE REQUIREMENTS.

H. ROUTE ALL WIRE AND CONDUIT CONCEALED UNLESS

OTHERWISE NOTED.

I. BOX AROUND RECESSED LIGHTING LUMINARIES AS REQUIRED

SO THAT ALL CODE REQUIRED CLEARANCES BETWEEN

COMBUSTIBLE MATERIALS, THERMAL INSULATION, ETC AND

LIGHTING LUMINARIES ARE MAINTAINED. FULLY COORDINATE

ALL REQUIREMENTS WITH THE GENERAL CONTRACTOR.

PROVIDE ENCLOSURES OVER RECESSED LIGHTING LUMINARIES

INSTALLED IN RATED CEILINGS SO ALL CODE REQUIRED

RATINGS ARE MAINTAINED. REFER TO ARCHITECTURAL

DRAWINGS FOR CEILING TYPES AND RATINGS. FULLY

COORDINATE ALL REQUIREMENTS WITH GENERAL

CONTRACTOR.

J. SEAL AROUND ALL CONDUIT AND CABLE PENETRATIONS

THROUGH WALLS, CEILINGS, AND FLOORS WITH AN APPROVED

DESIGN TESTED FIRE STOPPING SYSTEM TO MAINTAIN CODE

REQUIRED RATINGS. REFER TO ARCHITECTURAL DRAWINGS

FOR ADDITIONAL INFORMATION.

K. VACANCY SENSORS SHALL BE INSTALLED SO THAT NO

POSSIBILITY EXISTS WHERE THE SENSORS MAY BE COVERED

OR COVERAGE BLOCKED DURING ROUTINE USE. CONTRACTROR

SHALL RELOCATE SENSORS AS NEEDED IF LOCATION SHOWN IS

BLOCKED AFTER INSTALLATION.

L. PROVIDE CEILING MOUNTED DUAL TECHNOLOGY VACANCY

SENSOR FOR LOCAL CONTROL OF LIGHTING, UNLESS

OTHERWISE NOTED.

M. COORDINATE EXACT LOCATION AND ORIENTATION OF LIGHTING

FIXTURES IN AREAS THAT DO NOT HAVE CEILINGS AND CONTAIN

MECHANICAL AND/OR ELECTRICAL EQUIPMENT TO PROVIDE

MAXIMUM ILLUMINATION ON THE WORK PLANE.

N. CONTRACTOR SHALL INSTALL UNDER CABINET FIXTURES IN

SUCH A MANNER THAT FLEX CONDUIT SHALL BE CONCEALED

AND NOT BE VISIBLE FROM FRONT OF FIXTURE.

O. SEE ARCHITECTURAL BUILDING ELEVATIONS FOR LOCATION OF

BUILDING MOUNTED EXTERIOR LUMINARIES.

P. PROVIDE #10 AWG MINIMUM CONDUCTORS FOR ALL EXTERIOR

LIGHTING CIRCUITS. LIGHTING DEVICES SHOWN GRAY ARE FOR

REFERENCE.

Q. WHEN OCCUPANCY SENSORS ARE INSTALLED IN A COLORED

CEILING, PAINT SENSOR COVER TO MATCH CEILING. PROVIDE

PAINTED SENSOR COVER TO ARCHITECT FOR APPROVAL OF ALL

COLORS.

R. EXPOSED CONDUITS ARE NOT ALLOWED IN ANY AREA

ACCESSIBLE TO DETAINEE.

S. FOR LIGHTING CONTROL MATRIX REFER TO SHEET EL604-P1.

E F G H J K L

MATCHLINE - SEE:EL102E-P1

M A

T C

H

LI

N E

S

E E

:E L1

B

-P

M A

T C

H

LI

N E

S

E E

:x -E

L1

A -P

LEARNING

ENVIRONMENT

20152015

INSTRUCTOR

20252025

ASI1C

LAB/

EQUIPMENT

20372037

LEARNING

ENVIRONMENT

20272027

LEARNING

ENVIRONMENT

20382038

INSTRUCTOR

20142014

CORRIDOR

23042304

STAIR

21012101

25D

LAB

259259

BREAK

ROOM

261261

STORAGE

260260

VAULT

247247

VAULT

265265

MAINTENANCE

248248

MAINTENANCE

249249

25P

STORAGE

250B250B

25P

TCF

CLASSRM

251A251A

25P

STORAGE/

ADMIN

250A250A

LOBBY

201201

C O

R R

ID

O

R

INSTRUCTOR

20252025

CORRIDOR

23052305

D7

EL401-P1

LV3

H4H4

H1H1H1H1

KK

LV3

LV

M1

LV3

C

C

F1F1F1F1F1F1F1F1F1

F1F1F1F1F1F1F1F1F1

LV

LV3

G2

G2

G2

M1M1

F1

F1

LV

LV

LV3

M1M1

G2

G2

G2

G2

LV3G2

LV

M1

LV

F1

E2

E2

G2

M1

G2

24 4 2 4 2 4 2 4

4454545454

3323 3 3323 3 c c c c c c c c a a b

M1 M1 M1

M1

M1

M1 b b a a

H1 6 H1 6

H1 3H1 3 6 6H1 3

H1 6

H1 3 H1 3

H1 6 H1 6

H1 36

6 6

M1 b

M1 b

M1 a

M1 a

M1 a,b,c a,b,c a,b,c a,b,c a,b,c a,b,c a,b,ca,b,c a,b,c a,b,c a,b,ca,b,c a,b,c a,b,c

M1 M1 M1 b

M1

E1

E1

E1

E1

2 3

2 3

2 3

2 3

2 3

2 3

2 3

2 3

2 3

1 2

US Army Corps of Engineers ®

G

2 3 4 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

VHALL

J U

N E

W H

N B

-- 1 -3

-0

READY TO ADVERTISE (RTA)

V

IN

C E

N T

H A

L L R

E N

O V

A T

IO

N

P H

A S

E

C:\rvt\2019\10053876-M-VHALL-Central_Johnny.EstradaRL62D.rvt

7/7/2021 7:09:56 AM

EL704B-P1

E L E

C T

R

IC

A L

L

IG

H T

IN

G

P L A

N

L E

V E

L

A

R E

A B

P

H A

S E

A L T

F O

R T

G O

R D

O N

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E N

U E

S A

V A

N N

A H

G

A

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

L S

A D

IG

H

T P

O N

G S

U D

T M

A H

E R

L B

A Y

L O

N

C A

T E

G O

R Y

C O

D E

F Y

P

N

NORTH

KEY PLAN

A B C

F E D

1/8" = 1'-0" A1

ELECTRICAL - LIGHTING PLAN - LEVEL 2 - AREA B - PHASE 1 - ALT #1

8'4' 16'0

SCALE: 1/8"=1'-0"

1. ALL EXISTING LIGHTING FIXTURES IN THIS AREA SHALL BE RE-

INSTALLED TEMPORARY IN THE SAME LOCATION UNTIL PHASE 2.

2. UNLESS OTHERWISE NOTED, CIRCUIT ALL NORMAL LIGHTING

CIRCUIT TO PANEL NPH2NE1.

3. UNLESS OTHERWISE NOTED, CIRCUIT ALL LIFE SAFETY CIRCUIT

TO PANEL LPH2SE1.

4. PROVIDE 3 LOW VOLTAGE 3 BUTTON LIGHT SWITCHES WITH

RAISE/LOWER FEATURES IN ROOM. CONTROLS SHALL a, b, c AND

CONTROL ASSOCIATED LIGHTS WITHIN THAT SPACE.

5. PROVIDE AV CONTROL INTERFACE TO INTEGRATE LIGHTS WITH

AV EQUIPMENT IN SPACE REFER TO DETAIL C5, SHEET EL603-P1

FOR CONTROL INTERFACE DETAILS.

6. LIGHTS IN SPACE CONTROLLED BY FIXTURE MOUNTED

OCCUPANCY SENSOR.

7. PROVIDE EMERGENCY LIGHTING CONTROL RELAY IN THIS SPACE

REFER TO SHEET EL602-P1 DETAIL A1.

8. TEMPORARILY RECONNECT EXISTING LIGHTING CONTROL,

NORMAL AND EMERGENCY LIGHTING CIRCUIT IN THIS AREA TO

NEW PANEL NPH1N1 AND LPH1NE1 UNTIL PHASE 2. EXISTING

LIGHTING CONTROL TO REMAIN. ELECTRICAL CONTRACTOR TO

MAINTAIN THE LIGHTING CONTROL SYSTEM AS NEEDED TO

ENSURE THE EXISTING LIGHTING FIXTURES ARE CONTROLLED

PROPERLY.

9. THE CONTRACTOR SHALL ENSURE THE EMERGENCY LIGHTING

FIXTURES IN THE EGRESS PATH ARE CONTINUOUSLY

CONNECTED TO THE LIFE SAFETY CIRCUIT AND OPERATE

FUNCTIONALLY IN THE EVENT OF POWER FAILURE.

OS

OSOSOS

OSOS

OS

OS

OS

OS

OS

OS

OS

OS OS

OSOS

OSOS

OSOS

OS

OS

OS

OS

OS

OS OS

OS OS

OS OS

OS OS

OS OS

OS OS

OS OS

OS OS

OS OS

OS OS

OS OS

OS OS

OS OS

OS OS

OS OS

OS OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

LIGHTING GENERAL NOTES

LIGHTING KEYNOTES

A. FOR ELECTRICAL SYMBOLS AND ABBREVIATIONS REFER TO

DRAWINGS SHEET E-001-P1 AND E-002-P1.

B. ELECTRICAL WORK SHALL BE DONE IN CONFORMANCE WITH THE

CONSTRUCTION DOCUMENTS, ALL APPLICABLE CODES, ISSUED

DRAWINGS AND SPECIFICATIONS.

C. CONDUIT AND RACEWAYS SHOWN ARE DIAGRAMMATIC IN

NATURE. EXACT ROUTING AND REQUIREMENTS SHALL BE

COORDINATED WITH ALL TRADES PRIOR TO INSTALLATION.

D. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR

EXACT LOCATION OF ALL CEILING MOUNTED DEVICES.

E. COORDINATE THE INSTALLATION OF ALL RECESSED LIGHTING

LUMINARIES WITH ACTUAL CEILING TYPES. REFER TO

ARCHITECTURAL FINISH SCHEDULES FOR ADDITIONAL DETAILS.

F. COORDINATE THE INSTALLATION OF LIGHTING LUMINARIES WITH

AUDIO VISUAL SYSTEMS AND ALL OTHER TRADES. COORDINATE

EXACT LOCATION OF ALL ELECTRICAL, LOW VOLTAGE, AND

LIGHTING DEVICES WITH ARCHITECTURAL, CASEWORK (AUDIO

VISUAL SYSTEMS), AND GENERAL ELEVATIONS PRIOR TO

ROUGH-IN.

G. SUPPORT ALL RECESSED AND PENDANT MOUNTED LUMINARIES

FROM STRUCTURE IN ACCORDANCE WITH APPLICABLE BUILDING

CODE REQUIREMENTS.

H. ROUTE ALL WIRE AND CONDUIT CONCEALED UNLESS

OTHERWISE NOTED.

I. BOX AROUND RECESSED LIGHTING LUMINARIES AS REQUIRED

SO THAT ALL CODE REQUIRED CLEARANCES BETWEEN

COMBUSTIBLE MATERIALS, THERMAL INSULATION, ETC AND

LIGHTING LUMINARIES ARE MAINTAINED. FULLY COORDINATE

ALL REQUIREMENTS WITH THE GENERAL CONTRACTOR.

PROVIDE ENCLOSURES OVER RECESSED LIGHTING LUMINARIES

INSTALLED IN RATED CEILINGS SO ALL CODE REQUIRED

RATINGS ARE MAINTAINED. REFER TO ARCHITECTURAL

DRAWINGS FOR CEILING TYPES AND RATINGS. FULLY

COORDINATE ALL REQUIREMENTS WITH GENERAL

CONTRACTOR.

J. SEAL AROUND ALL CONDUIT AND CABLE PENETRATIONS

THROUGH WALLS, CEILINGS, AND FLOORS WITH AN APPROVED

DESIGN TESTED FIRE STOPPING SYSTEM TO MAINTAIN CODE

REQUIRED RATINGS. REFER TO ARCHITECTURAL DRAWINGS

FOR ADDITIONAL INFORMATION.

K. VACANCY SENSORS SHALL BE INSTALLED SO THAT NO

POSSIBILITY EXISTS WHERE THE SENSORS MAY BE COVERED

OR COVERAGE BLOCKED DURING ROUTINE USE. CONTRACTROR

SHALL RELOCATE SENSORS AS NEEDED IF LOCATION SHOWN IS

BLOCKED AFTER INSTALLATION.

L. PROVIDE CEILING MOUNTED DUAL TECHNOLOGY VACANCY

SENSOR FOR LOCAL CONTROL OF LIGHTING, UNLESS

OTHERWISE NOTED.

M. COORDINATE EXACT LOCATION AND ORIENTATION OF LIGHTING

FIXTURES IN AREAS THAT DO NOT HAVE CEILINGS AND CONTAIN

MECHANICAL AND/OR ELECTRICAL EQUIPMENT TO PROVIDE

MAXIMUM ILLUMINATION ON THE WORK PLANE.

N. CONTRACTOR SHALL INSTALL UNDER CABINET FIXTURES IN

SUCH A MANNER THAT FLEX CONDUIT SHALL BE CONCEALED

AND NOT BE VISIBLE FROM FRONT OF FIXTURE.

O. SEE ARCHITECTURAL BUILDING ELEVATIONS FOR LOCATION OF

BUILDING MOUNTED EXTERIOR LUMINARIES.

P. PROVIDE #10 AWG MINIMUM CONDUCTORS FOR ALL EXTERIOR

LIGHTING CIRCUITS. LIGHTING DEVICES SHOWN GRAY ARE FOR

REFERENCE.

Q. WHEN OCCUPANCY SENSORS ARE INSTALLED IN A COLORED

CEILING, PAINT SENSOR COVER TO MATCH CEILING. PROVIDE

PAINTED SENSOR COVER TO ARCHITECT FOR APPROVAL OF ALL

COLORS.

R. EXPOSED CONDUITS ARE NOT ALLOWED IN ANY AREA

ACCESSIBLE TO DETAINEE.

S. FOR LIGHTING CONTROL MATRIX REFER TO SHEET EL604-P1.

L M N P Q

M A

T C

H

LI

N E

S

E E

:E L1

B

-P

MATCHLINE - SEE:EL102D-P1

DOWN

LEARNING

ENVIRONMENT

20192019

LEARNING

ENVIRONMENT

20182018

LEARNING

ENVIRONMENT

20172017

LEARNING

ENVIRONMENT

20162016

INSTRUCTOR

20252025

INSTRUCT

STORAGE

20242024

TELECOM

20212021

ELEC

20222022

ELEV

#2

22022202

CAVE

20202020

LEARNING

ENVIRONMENT

20322032

LEARNING

ENVIRONMENT

20332033

LEARNING

ENVIRONMENT

20312031

LEARNING

ENVIRONMENT

20342034

LEARNING

ENVIRONMENT

20302030

LEARNING

ENVIRONMENT

20352035

LEARNING

ENVIRONMENT

20292029

LEARNING

ENVIRONMENT

20362036

CAVE

20402040

CONF

8-10

PN

20422042

CORRIDOR

23042304

CORRIDOR

23052305

WORK/

COPY

2025A2025A

CORRIDOR

23042304

CORRIDOR

23042304

F1

F1 F1 F1

LV

3F5

F5

F5

F5

F5

F5

LV5

F4F4

G1

LV5

F1F1

LV3

H4H4

G1

F1

F1

LV

B2

B3

B2B2

B3

B3

B3

LV5LVLV3

H1H1H1H1

LV3LV3

LV

LV

G2

G2

G1 G1

G2

G2 G2

G2

M1 M1 M1 M1M1M1

E1

F1 F1 F1 F1 F1 F1 F1

F1 F1 F1 F1 F1

F1F1F1F1F1F1F1F1F1F1

F1F1F1F1F1F1F1F1F1F1F1F1

F1F1

LV

LV3

LV

LV3

LV

G2

G2 G2

G2

G2

E1

F1

F1 F1

LV3LV3

LV

LV

G2

G2

G2 G2

G2

G2 G2

G2

M1 M1 M1 M1M1M1

LV3

LV

G2

G2LV3

LV

G2

G2

G2

LV3G2

LV

G2

LV3G2

LV

G2

LV3G2

LV

LV

G2

G2

G2LV3

F1

F1 F1

E2E2

E2 E2

E1

E1

Y

B1

G2

G2

G2

G2

G2

G2

M1

4 4

4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4

2 B1 2B1 2

B1 2 B1 2B1 2

C 5 4 4

45454 5 4

545454545454

5 5 1 1

1 5 221

1 1

C2

NPH2NE1

c c c c c c c c c c c c c c c c c c c cc c c c c c c cc cc c c c c cc c c

M1

M1 a a b b b b a a b b b b a a

M1 b

M1 b

M1 a

M1 b

M1 b

M1 a

M1 b

M1 b

M1 b

M1 b

M1 a

M1 a

M1 b

M1 b

M1 a

M1 b

M1 b

M1 a

M1 b

M1 b

M1 b

M1 b

M1 a

M1 a,b,c a,b,c a,b,c a,b,c a,b,c a,b,c a,b,c a,b,c a,b,c a,b,c a,b,c a,b,c a,b,c a,b,c a,b,c a,b,c a,b,c a,b,ca,b,c a,b,ca,b,c a,b,ca,b,c a,b,ca,b,c a,b,ca,b,c a,b,ca,b,ca,b,c a,b,c a,b,c a,b,c a,b,c a,b,c a,b,ca,b,c a,b,ca,b,c a,b,c a,b,ca,b,c a,b,c a,b,c a,b,ca,b,c a,b,c a,b,c

F1

F1

F1

F1

F1

F1

F1

F1

F1

M1

E2

E1

E1

E1

E1

E1

E1

E1

E1

W2

W2

W2

W2

W2

1 2 1 2 1 2 1 2

1 2

1 2

1 2

1 2

1 2

1 2

1 2 1 2 1 2

1 2

1 2 1 21 21 2

1 2

1 2

1 2

3 3

3 3

3 3

4 4 4 4

3 3

3 3

5 5 5

5 5

5 5

US Army Corps of Engineers ®

G

2 3 4 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

VHALL

J U

N E

W H

N B

-- 1 -3

-0

READY TO ADVERTISE (RTA)

V

IN

C E

N T

H A

L L R

E N

O V

A T

IO

N

P H

A S

E

C:\rvt\2019\10053876-M-VHALL-Central_Johnny.EstradaRL62D.rvt

7/7/2021 7:10:03 AM

EL704C-P1

E L E

C T

R

IC

A L

L

IG

H T

IN

G

P L A

N

L E

V E

L

A

R E

A C

P

H A

S E

A L T

F O

R T

G O

R D

O N

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E N

U E

S A

V A

N N

A H

G

A

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

L S

A D

IG

H

T P

O N

G S

U D

T M

A H

E R

L B

A Y

L O

N

C A

T E

G O

R Y

C O

D E

F Y

P

N

NORTH

KEY PLAN

A B C

F E D

1/8" = 1'-0" A1

ELECTRICAL - LIGHTING PLAN - LEVEL 2 - AREA C - PHASE 1 - ALT #1

8'4' 16'0

SCALE: 1/8"=1'-0"

1. UNLESS OTHERWISE NOTED, CIRCUIT ALL NORMAL LIGHTING

CIRCUIT TO PANEL NPH2NE1.

2. UNLESS OTHERWISE NOTED, CIRCUIT ALL LIFE SAFETY CIRCUIT

TO PANEL LPH2SE1.

3. PROVIDE 3 LOW VOLTAGE 3 BUTTON LIGHT SWITCHES WITH

RAISE/LOWER FEATURES IN ROOM. CONTROLS SHALL a, b, c AND

CONTROL ASSOCIATED LIGHTS WITHIN THAT SPACE.

4. PROVIDE AV CONTROL INTERFACE TO INTEGRATE LIGHTS WITH

AV EQUIPMENT IN SPACE REFER TO DETAIL C5, SHEET EL603-P1

FOR CONTROL INTERFACE DETAILS.

5. PROVIDE EMERGENCY LIGHTING CONTROL RELAY IN THIS SPACE

REFER TO SHEET EL602-P1 DETAIL A1.

GI041-P1 GENERAL - COVER SHEET - BID ALTERNATE
GI042-P1 GENERAL - INDEX OF DRAWINGS - BID ALTERNATE
SF703B-P1 STRUCTURAL - FRAMING PLAN - ROOF, AREA B - PHASE 1 - BID ALT #1
SF703C-P1 STRUCTURAL - FRAMING PLAN - ROOF, AREA C - PHASE 1 - BID ALT #1
S-710-P1 STRUCTURAL - STEEL - TYPICAL DETAILS - BID ALT #1
A-702B-P1 ARCHITECTURAL - FLOOR PLAN - LEVEL 2, AREA B - PHASE 1 - BID ALT #1
A-702C-P1 ARCHITECTURAL - FLOOR PLAN - LEVEL 2, AREA C - PHASE 1 - BID ALT #1
A-704B-P1 ARCHITECTURAL - REFLECTED CEILING PLAN - LEVEL 2, AREA B - PHASE 1 - BID ALT #1
A-704C-P1 ARCHITECTURAL - REFLECTED CEILING PLAN - LEVEL 2, AREA C - PHASE 1 - BID ALT #1
A-705-P1 ARCHITECTURAL - UPFOLDING PARTITION DETAILS - PHASE 1 - BID ALT #1
EL704B-P1 ELECTRICAL - LIGHTING PLAN - LEVEL 2 - AREA B - PHASE 1 - ALT #1
EL704C-P1 ELECTRICAL - LIGHTING PLAN - LEVEL 2 - AREA C - PHASE 1 - ALT #1

File details come from the government source that posted it. Updated .