W912HN-21-B-3008_DRAWINGS_VOL1D.pdf

PDF 25 MB Posted

Attached to
PN ST-22018-8P Vincent Hall Renovation, Phase 1, Fort Gordon, GA
Solicitation number
W912HN21B3008
Issued by

About this file

This solicitation is for Project Number ST-22018-8P, a Vincent Hall Renovation at Fort Gordon, Georgia. The project scope includes 56,555 square feet of interior renovation and associated mechanical and electrical infrastructure upgrades to support both Phase 1 and future phases. Phase 1 will construct learning environments, support space, and other program functions. The magnitude of this requirement from the Department of the Army Corps of Engineers Engineering District Savannah is between $10 million and $25 million. This is a full and open, unrestricted acquisition under NAICS Code 236220 with a price evaluation preference for HUBZone small businesses. Bidders must register in the System for Award Management, and there are eight specifications and drawing files in addition to the solicitation file.

View the file

Other files

File Type Posted
C.04. W912HN21B3008 - Vincent Hall Reno. -HUB zone preference ABSTRACT.pdf PDF
W912HN21B3008 BID OPENING ATTENDEES.pdf PDF
C.04. W912HN21B3008 - Vincent Hall Reno. -HUB zone preference.pdf PDF
W912HN-21-B-3008_DRAWINGS_VOL1A_AMD2.pdf PDF
W912HN-21-B-3008_DRAWINGS_VOL1D_AMD2.pdf PDF
B.08 W912HN21B3008 Amendment 0002.pdf PDF
B.08 W912HN21B3008 Amendment 0002 CC.pdf PDF
W912HN-21-B-3008_DRAWINGS_VOL1A_AMD1.pdf PDF
W912HN-21-B-3008_DRAWINGS_VOL1B_AMD1.pdf PDF
B.08 W912HN21B3008 Amendment 0001.pdf PDF
Phase1_RTA_V2-C_Div_25-33_Appendices_AMD1.pdf PDF
W912HN-21-B-3008_DRAWINGS_VOL1C_AMD1.pdf PDF
Phase1_RTA_V2-A_Div_00-07_AMD1.pdf PDF
W912HN-21-B-3008_DRAWINGS_VOL1D_AMD1.pdf PDF
Phase1_RTA_V2-B_Div_08-23_AMD1.pdf PDF
B.08 W912HN21B3008 Amendment 0001 CC.pdf PDF
Vincent Hall Site Visit Attendance Roster.pdf PDF
Vincent Hall Pre-Bid Site Visit Synopsis.docx DOCX document
B.08 - Solicitation W912HN21B3008 - Vincent Hall.pdf PDF
Phase1_RTA_V2-A_Div_00-07.pdf PDF
W912HN-21-B-3008_DRAWINGS_VOL1C.pdf PDF
Phase1_RTA_V2-B_Div_08-23.pdf PDF
W912HN-21-B-3008_DRAWINGS_VOL1A.pdf PDF
W912HN-21-B-3008_DRAWINGS_VOL1B.pdf PDF
W912HN-21-B-3008_DRAWINGS_VOL1E.pdf PDF
B.08_W912HN20B3008 Vincent Hall Solicitation.pdf PDF
Phase1_RTA_V2-C_Div_25-33 Appendices.pdf PDF
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

US Army Corps of Engineers ®

G

2 3 4 6 7 8 9 10

F

E

D

C

B

A

D A

T E

US Army Corps of Engineers ®

SOLICITATION NO.:

CONTRACT NO.:

ISSUE DATE:

VOLUME:

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

HDR Architecture

3001 WASHINGTON BLVD., SUITE 200

ARLINGTON, VIRGINIA 22201

(703)518-8500

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

SAVANNAH DISTRICT

VHALL

J U

N E

W H

N B

-- 1 -3

-0

READY TO ADVERTISE (RTA)

V

IN

C E

N T

H A

L L R

E N

O V

A T

IO

N

P H

A S

E

JUNE 2021

W912HN21B3008

VINCENT HALL RENOVATION PHASE 1

C:\rvt\2019\10053876-A-VHALL-Central_hdr-alx-rcruz.rvt

7/8/2021 10:45:05 AM

FORT GORDON, GEORGIA

FY20 PN 92894

GI031-P1

G E

N E

R A

L

C O

V E

R S

H E

E T

F O

R T

G O

R D

O N

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E N

U E

S A

V A

N N

A H

G

A

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

N T

R A

N

R C

R U

Z

T M

A H

E R

H E

Z Z

E D

D

IN

E

C A

T E

G O

R Y

C O

D E

F Y

P

N

1296 Broad Street | Augusta, GA 30901 | (706) 724-5756

T E C H N O L O G I E S 10440 Little Patuxent Parkway, Suite 900 | Columbia, MD 21044 | (443) 832-3308

10280 Old Columbia Road | Columbia, MD 21046 | (410) 290-9301

1D

G

2 3 4 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

VHALL

J U

N E

W H

N B

-- 1 -3

-0

READY TO ADVERTISE (RTA)

V

IN

C E

N T

H A

L L R

E N

O V

A T

IO

N

P H

A S

E

C:\rvt\2019\10053876-A-VHALL-Central_hdr-alx-rcruz.rvt

7/8/2021 3:16:51 PM

GI032-P1

G E

N E

R A

L

IN

D

E X

O F

D R

A W

IN

G

S

F O

R T

G O

R D

O N

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E N

U E

S A

V A

N N

A H

G

A

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

N T

R A

N

R C

R U

Z

T M

A H

E R

H E

Z Z

E D

D

IN

E

C A

T E

G O

R Y

C O

D E

F Y

P

N

A-101E-P1 ARCHITECTURAL - FLOOR PLAN - LEVEL 1, AREA E - PHASE 1

A-101D-P1 ARCHITECTURAL - FLOOR PLAN - LEVEL 1, AREA D - PHASE 1

A-101C-P1 ARCHITECTURAL - FLOOR PLAN - LEVEL 1, AREA C - PHASE 1

A-101B-P1 ARCHITECTURAL - FLOOR PLAN - LEVEL 1, AREA B - PHASE 1

A-101-P1 ARCHITECTURAL - FLOOR PLAN - LEVEL 1, OVERALL - PHASE 1

AD501-P1 ARCHTIECTURAL - DEMOLITION DETAILS - PHASE 1

AD201-P1 ARCHITECTURAL - DEMOLITION ELEVATIONS - PHASE 1

AD112-P1 ARCHITECTURAL - TEMPORARY PARTITION LOCATION PLAN - LEVEL 2 - PHASE 1

AD111-P1 ARCHITECTURAL - TEMPORARY PARTITION LOCATION PLAN - LEVEL 1 - PHASE 1

AD103-P1 ARCHITECTURAL - DEMOLITION PLAN - ROOF - PHASE 1

AD102-P1 ARCHITECTURAL - DEMOLITION PLAN - LEVEL 2 - PHASE 1

AD101-P1 ARCHITECTURAL - DEMOLITION PLAN - LEVEL 1 - PHASE 1

AD001-P1 ARCHITECTURAL - GENERAL DEMOLITION NOTES - PHASE 1

ARCHITECTURAL

GI014-P1 GENERAL - INDEX OF DRAWINGS - BID ALTERNATE

GI013-P1 GENERAL - INDEX OF DRAWINGS

GI012-P1 GENERAL - INDEX OF DRAWINGS

GI011-P1 GENERAL - COVER SHEET

GENERAL - VOLUME 1B

S-540-P1 STRUCTURAL - MASONRY - TYPICAL DETAILS

S-523-P1 STRUCTURAL - STEEL - SECTIONS AND DETAILS

S-522-P1 STRUCTURAL - STEEL - SECTIONS AND DETAILS

S-521-P1 STRUCTURAL - STEEL - TYPICAL DETAILS

S-520-P1 STRUCTURAL - STEEL - TYPICAL DETAILS

S-503-P1 STRUCTURAL - CONCRETE - TYPICAL DETAILS

S-502-P1 STRUCTURAL - CONCRETE - TYPICAL DETAILS

S-501-P1 STRUCTURAL - CONCRETE - TYPICAL DETAILS

S-213-P1 STRUCTURAL - STEEL BRACED FRAME ELEVATIONS

S-212-P1 STRUCTURAL - STEEL BRACED FRAME ELEVATIONS

S-211-P1 STRUCTURAL - STEEL BRACED FRAME ELEVATIONS

S-210-P1 STRUCTURAL - STEEL BRACED FRAME ELEVATIONS

SF104-P1 STRUCTURAL - PARTIAL FRAMING PLANS - PHASE 1

SF103D-P1 STRUCTURAL - FRAMING PLAN - ROOF, AREA D - PHASE 1

SF103C-P1 STRUCTURAL - FRAMING PLAN - ROOF, AREA C - PHASE 1

SF103B-P1 STRUCTURAL - FRAMING PLAN - ROOF, AREA B - PHASE 1

SF103-P1 STRUCTURAL - FRAMING PLAN - ROOF, OVERALL - PHASE 1

SF102E-P1 STRUCTURAL - FRAMING PLAN - LEVEL 2, AREA E - PHASE 1

SF102D-P1 STRUCTURAL - FRAMING PLAN - LEVEL 2, AREA D - PHASE 1

SF102C-P1 STRUCTURAL - FRAMING PLAN - LEVEL 2, AREA C - PHASE 1

SF102B-P1 STRUCTURAL - FRAMING PLAN - LEVEL 2, AREA B - PHASE 1

SF102-P1 STRUCTURAL - FRAMING PLAN - LEVEL 2, OVERALL - PHASE 1

SF101E-P1 STRUCTURAL - FRAMING PLAN - LEVEL 1, AREA E - PHASE 1

SF101D-P1 STRUCTURAL - FRAMING PLAN - LEVEL 1, AREA D - PHASE 1

SF101C-P1 STRUCTURAL - FRAMING PLAN - LEVEL 1, AREA C - PHASE 1

SF101-P1 STRUCTURAL - FRAMING PLAN - LEVEL 1, OVERALL - PHASE 1

SD103D-P1 STRUCTURAL - DEMOLITION PLAN - ROOF, AREA D - PHASE 1

SD103C-P1 STRUCTURAL - DEMOLITION PLAN - ROOF, AREA C - PHASE 1

SD103-P1 STRUCTURAL - DEMOLITION PLAN - ROOF, OVERALL - PHASE 1

SD102E-P1 STRUCTURAL - DEMOLITION PLAN - LEVEL 2, AREA E - PHASE 1

SD102D-P1 STRUCTURAL - DEMOLITION PLAN - LEVEL 2, AREA D - PHASE 1

SD102C-P1 STRUCTURAL - DEMOLITION PLAN - LEVEL 2, AREA C - PHASE 1

SD102B-P1 STRUCTURAL - DEMOLITION PLAN - LEVEL 2, AREA B - PHASE 1

SD102-P1 STRUCTURAL - DEMOLITION PLAN - LEVEL 2, OVERALL - PHASE 1

SD101E-P1 STRUCTURAL - DEMOLITION PLAN - LEVEL 1, AREA E - PHASE 1

SD101D-P1 STRUCTURAL - DEMOLITION PLAN - LEVEL 1, AREA D - PHASE 1

SD101C-P1 STRUCTURAL - DEMOLITION PLAN - LEVEL 1, AREA C - PHASE 1

SD101-P1 STRUCTURAL - DEMOLITION PLAN - LEVEL 1, OVERALL - PHASE 1

S-006-P1 COMPONENTS & CLADDING WIND PRESSURES

S-005-P1 COMPONENTS & CLADDING WIND PRESSURES

S-004-P1 STRUCTURAL - SCHEDULE OF SPECIAL INSPECTION

S-003-P1 STRUCTURAL - SCHEDULE OF SPECIAL INSPECTION

S-002-P1 STRUCTURAL - GENERAL NOTES (CONT)

S-001-P1 STRUCTURAL - GENERAL NOTES

STRUCTURAL

CE502-P1 CIVIL - E.S.P.C. DETAILS & NOTES - PHASE 1

CE501-P1 CIVIL - E.S.P.C. DETAILS & NOTES - PHASE 1

CE101-P1 CIVIL - E.S.P.C. PLAN - PHASE 1

C-502-P1 CIVIL - SITE DETAILS - PHASE 1

C-501-P1 CIVIL - SITE DETAILS - PHASE 1

CG101-P1 CIVIL - PARTIAL GRADING AND DRAINAGE PLAN - PHASE 1

CU101-P1 CIVIL - SITE UTILITY PLAN - PHASE 1

CS101-P1 CIVIL - SITE LAYOUT PLAN - PHASE 1

CD101-P1 CIVIL - SITE DEMOLITION PLAN - PHASE 1

CV101-P1 CIVIL - SITE EXISTING CONDITIONS PLAN - PHASE 1

C-001-P1 CIVIL - GENERAL NOTES, LEGEND & LOCATION MAP - PHASE 1

CIVIL

G-112-P1 LIFE SAFETY FLOOR PLAN - LEVEL 2 - OVERALL - FINAL - PHASE 1

G-111-P1 LIFE SAFETY FLOOR PLAN - LEVEL 2 - OVERALL - FINAL - PHASE 1

G-102-P1 LIFE SAFETY FLOOR PLAN - LEVEL 2 - OVERALL - CONSTRUCTION - PHASE 1

G-101-P1 LIFE SAFETY FLOOR PLAN - LEVEL 1 - OVERALL - CONSTRUCTION - PHASE 1

G-100-P1 LIFE SAFETY - SITE PLAN - PHASE 1

G-012-P1 LIFE SAFETY BUILDING CODES ANALYSIS - PHASE 1

G-011-P1 LIFE SAFETY BUILDING CODES ANALYSIS - PHASE 1

G-010-P1 LIFE SAFETY BUILDING CODES ANALYSIS - PHASE 1

LIFE SAFETY

GI007-P1 GENERAL - SCOPE DIAGRAMS - PHASE 1

GI006-P1 GENERAL - LOCATION AND VICINITY MAPS

GI004-P1 GENERAL - INDEX OF DRAWINGS - BID ALTERNATE

GI003-P1 GENERAL - INDEX OF DRAWINGS

GI002-P1 GENERAL - INDEX OF DRAWINGS

GI001-P1 GENERAL - COVER SHEET

GENERAL - VOLUME 1A

Sheet ID Drawing Title

Vincent Hall Drawing Index

A-611-P1 ARCHITECTURAL - INT. DEMOUNTABLE & EXT. STOREFRONT SCHEDULE, ELEVATIONS & DETAILS - PHASE 1

A-605-P1 ARCHITECTURAL - DOOR & FRAME DETAILS - PHASE 1

A-604-P1 ARCHITECTURAL - DOOR & FRAME DETAILS - PHASE 1

A-603-P1 ARCHITECTURAL - DOOR & FRAME DETAILS - PHASE 1

A-602-P1 ARCHITECTURAL - DOOR FRAME TYPES - PHASE 1

A-601-P1 ARCHITECTURAL - DOOR SCHEDULE - PHASE 1

A-555-P1 ARCHITECTURAL - EXTERIOR DETAILS - ROOF - PHASE 1

A-554-P1 ARCHITECTURAL - EXTERIOR DETAILS - PHASE 1

A-553-P1 ARCHITECTURAL - EXTERIOR DETAILS - PHASE 1

A-552-P1 ARCHITECTURAL - EXTERIOR DETAILS - PHASE 1

A-551-P1 ARCHITECTURAL - EXTERIOR DETAILS - PHASE 1

A-542-P1 ARCHITECTURAL - DETAILS - INTERIOR FINISH - PHASE 1

A-541-P1 ARCHITECTURAL - NOTES AND FINISH LEGEND - PHASE 1

A-531-P1 ARCHITECTURAL - INTERIOR CASEWORK DETAILS - PHASE 1

A-522-P1 ARCHITECTURAL - RAISED ACCESS FLOOR DETAILS - PHASE 1

A-521-P1 ARCHITECTURAL - RAISED ACCESS FLOOR DETAILS - PHASE 1

A-512-P1 ARCHITECTURAL - CEILING DETAILS - PHASE 1

A-511-P1 ARCHITECTURAL - CEILING DETAILS - PHASE 1

A-506-P1 ARCHITECTURAL - COLUMN PLAN DETAILS - PHASE 1

A-505-P1 ARCHITECTURAL - COLUMN PLAN DETAILS - PHASE 1

A-504-P1 ARCHITECTURAL - STANDARD PARTITION DETAILS - PHASE 1

A-503-P1 ARCHITECTURAL - STANDARD PARTITION DETAILS - PHASE 1

A-502-P1 ARCHITECTURAL - STANDARD PARTITION DETAILS - PHASE 1

A-501-P1 ARCHITECTURAL - PARTITION TYPES - PHASE 1

A-452-P1 ARCHITECTURAL - ENLARGED INTERIOR ELEVATIONS - PHASE 1

A-451-P1 ARCHITECTURAL - ENLARGED INTERIOR ELEVATIONS - PHASE 1

A-441-P1 ARCHITECTURAL - FURNITURE PLAN - TYPICAL ROOMS - PHASE 1

A-433-P1 ARCHITECTURAL - ELEVATOR DETAILS - PHASE 1

A-432-P1 ARCHITECTURAL - ELEVATOR 1 ROOF VESTIBULE ELEVATIONS - PHASE 1

A-431-P1 ARCHITECTURAL - ENLARGED PLANS & SECTIONS - ELEVATOR 1 - PHASE 1

A-426-P1 ARCHITECTURAL - STAIR DETAILS - PHASE 1

A-425-P1 ARCHITECTURAL - STAIR DETAILS - PHASE 1

A-424-P1 ARCHITECTURAL - STAIR DETAILS - PHASE 1

A-423-P1 ARCHITECTURAL - STAIR DETAILS - PHASE 1

A-422-P1 ARCHITECTURAL - ENLARGED PLANS & SECTIONS - STAIR 3 - PHASE 1

A-421-P1 ARCHITECTURAL - ENLARGED PLANS & SECTIONS - STAIR 1 - PHASE 1

A-419-P1 ARCHITECTURAL - TYPICAL LAYOUTS & MOUNTING HEIGHTS - PHASE 1

A-418-P1 ARCHITECTURAL - TYPICAL LAYOUTS & MOUNTING HEIGHTS - PHASE 1

A-414-P1 ARCHITECTURAL - ENLARGED ELEVATIONS - TOILETS - PHASE 1

A-413-P1 ARCHITECTURAL - ENLARGED FINISH PLANS - EAST TOILETS LEVEL 1 & 2 - PHASE 1

A-412-P1 ARCHITECTURAL - ENLARGED PLANS - EAST TOILETS LEVEL 2 - PHASE 1

A-411-P1 ARCHITECTURAL - ENLARGED PLANS - EAST TOILETS LEVEL 1 - PHASE 1

A-312-P1 ARCHITECTURAL - EXTERIOR WALL SECTIONS AND ELEVATIONS - PHASE 1

A-311-P1 ARCHITECTURAL - EXTERIOR WALL SECTIONS AND ELEVATIONS - PHASE 1

A-201-P1 ARCHITECTURAL - EXTERIOR ELEVATIONS - PHASE 1

A-152E-P1 ARCHITECTURAL - FURNITURE PLAN - LEVEL 2, AREA E - PHASE 1

A-152D-P1 ARCHITECTURAL - FURNITURE PLAN - LEVEL 2, AREA D - PHASE 1

A-152C-P1 ARCHITECTURAL - FURNITURE PLAN - LEVEL 2, AREA C - PHASE 1

A-152B-P1 ARCHITECTURAL - FURNITURE PLAN - LEVEL 2, AREA B - PHASE 1

A-152-P1 ARCHITECTURAL - FURNITURE PLAN - LEVEL 2, OVERALL - PHASE 1

A-151C-P1 ARCHITECTURAL - FURNITURE PLAN - LEVEL 1, AREA C - PHASE 1

A-151B-P1 ARCHITECTURAL - FURNITURE PLAN - LEVEL 1, AREA B - PHASE 1

A-151-P1 ARCHITECTURAL - FURNITURE PLAN - LEVEL 1, OVERALL - PHASE 1

A-142E-P1 ARCHITECTURAL - FINISH PLAN - LEVEL 2, AREA E - PHASE 1

A-142D-P1 ARCHITECTURAL - FINISH PLAN - LEVEL 2, AREA D - PHASE 1

A-142C-P1 ARCHITECTURAL - FINISH PLAN - LEVEL 2, AREA C - PHASE 1

A-142B-P1 ARCHITECTURAL - FINISH PLAN - LEVEL 2, AREA B - PHASE 1

A-142-P1 ARCHITECTURAL - FINISH PLAN - LEVEL 2, OVERALL - PHASE 1

A-141E-P1 ARCHITECTURAL - FINISH PLAN - LEVEL 1, AREA E - PHASE 1

A-141D-P1 ARCHITECTURAL - FINISH PLAN - LEVEL 1, AREA D - PHASE 1

A-141C-P1 ARCHITECTURAL - FINISH PLAN - LEVEL 1, AREA C - PHASE 1

A-141B-P1 ARCHITECTURAL - FINISH PLAN - LEVEL 1, AREA B - PHASE 1

A-141-P1 ARCHITECTURAL - FINISH PLAN - LEVEL 1, OVERALL - PHASE 1

A-132E-P1 ARCHITECTURAL - RAISED FLOOR PLAN - LEVEL 2, AREA E - PHASE 1

A-132D-P1 ARCHITECTURAL - RAISED FLOOR PLAN - LEVEL 2, AREA D - PHASE 1

A-132C-P1 ARCHITECTURAL - RAISED FLOOR PLAN - LEVEL 2, AREA C - PHASE 1

A-132B-P1 ARCHITECTURAL - RAISED FLOOR PLAN - LEVEL 2, AREA B - PHASE 1

A-132-P1 ARCHITECTURAL - RAISED FLOOR PLAN - LEVEL 2, OVERALL - PHASE 1

A-131D-P1 ARCHITECTURAL - RAISED FLOOR PLAN - LEVEL 1, AREA D - PHASE 1

A-131C-P1 ARCHITECTURAL - RAISED FLOOR PLAN - LEVEL 1, AREA C - PHASE 1

A-131B-P1 ARCHITECTURAL - RAISED FLOOR PLAN - LEVEL 1, AREA B - PHASE 1

A-131-P1 ARCHITECTURAL - RAISED FLOOR PLAN - LEVEL 1, OVERALL - PHASE 1

A-122E-P1 ARCHITECTURAL - REFLECTED CEILING PLAN - LEVEL 2, AREA E - PHASE 1

A-122D-P1 ARCHITECTURAL - REFLECTED CEILING PLAN - LEVEL 2, AREA D - PHASE 1

A-122C-P1 ARCHITECTURAL - REFLECTED CEILING PLAN - LEVEL 2, AREA C - PHASE 1

A-122B-P1 ARCHITECTURAL - REFLECTED CEILING PLAN - LEVEL 2, AREA B - PHASE 1

A-122-P1 ARCHITECTURAL - REFLECTED CEILING PLAN - LEVEL 2, OVERALL - PHASE 1

A-121E-P1 ARCHITECTURAL - REFLECTED CEILING PLAN - LEVEL 1, AREA E - PHASE 1

A-121D-P1 ARCHITECTURAL - REFLECTED CEILING PLAN - LEVEL 1, AREA D - PHASE 1

A-121C-P1 ARCHITECTURAL - REFLECTED CEILING PLAN - LEVEL 1, AREA C - PHASE 1

A-121B-P1 ARCHITECTURAL - REFLECTED CEILING PLAN - LEVEL 1, AREA B - PHASE 1

A-121-P1 ARCHITECTURAL - REFLECTED CEILING PLAN - LEVEL 1, OVERALL - PHASE 1

A-112-P1 ARCHITECTURAL - ACOUSTIC BOUNDARY FLOOR PLAN - LEVEL 2 - PHASE 1

A-111-P1 ARCHITECTURAL - ACOUSTIC BOUNDARY FLOOR PLAN - LEVEL 1 - PHASE 1

A-103D-P1 ARCHITECTURAL - ROOF PLAN - AREA D - PHASE 1

A-103C-P1 ARCHITECTURAL - ROOF PLAN - AREA C - PHASE 1

A-103B-P1 ARCHITECTURAL - ROOF PLAN - AREA B - PHASE 1

A-103-P1 ARCHITECTURAL - ROOF PLAN - OVERALL - PHASE 1

A-102E-P1 ARCHITECTURAL - FLOOR PLAN - LEVEL 2, AREA E - PHASE 1

A-102D-P1 ARCHITECTURAL - FLOOR PLAN - LEVEL 2, AREA D - PHASE 1

A-102C-P1 ARCHITECTURAL - FLOOR PLAN - LEVEL 2, AREA C - PHASE 1

A-102B-P1 ARCHITECTURAL - FLOOR PLAN - LEVEL 2, AREA B - PHASE 1

A-102-P1 ARCHITECTURAL - FLOOR PLAN - LEVEL 2, OVERALL - PHASE 1

Sheet ID Drawing Title

Vincent Hall Drawing Index

P-651-P1 PLUMBING - SCHEDULES

P-630-P1 PLUMBING - RISER DIAGRAM - NATURAL GAS

P-620-P1 PLUMBING - RISER DIAGRAM - SUPPLY

P-610-P1 PLUMBING - RISER DIAGRAM - WASTE AND VENT

P-502-P1 PLUMBING - DETAILS

P-501-P1 PLUMBING - DETAILS

PP102E-P1 PLUMBING - SUPPLY PLAN - LEVEL 2, AREA E-PHASE 1

PP102D-P1 PLUMBING - SUPPLY PLAN - LEVEL 2, AREA D-PHASE 1

PP102C-P1 PLUMBING - SUPPLY PLAN - LEVEL 2, AREA C-PHASE 1

PP102-P1 PLUMBING - SUPPLY PLAN - LEVEL 2,OVERALL-PHASE 1

PP101D-P1 PLUMBING - SUPPLY PLAN - LEVEL 1, AREA D-PHASE 1

PP101C-P1 PLUMBING - SUPPLY PLAN - LEVEL 1, AREA C-PHASE 1

PP101B-P1 PLUMBING - SUPPLY PLAN - LEVEL 1, AREA B-PHASE 1

PP101-P1 PLUMBING - SUPPLY PLAN - LEVEL 1, OVERALL-PHASE 1

PL103E-P1 PLUMBING - WASTE AND VENT PLAN - ROOF, AREA E-PHASE 1

PL103D-P1 PLUMBING - WASTE AND VENT PLAN - ROOF, AREA D-PHASE 1

PL103-P1 PLUMBING - WASTE AND VENT PLAN - ROOF, OVERALL-PHASE 1

PL102E-P1 PLUMBING - WASTE AND VENT PLAN - LEVEL 2, AREA E-PHASE 1

PL102D-P1 PLUMBING - WASTE AND VENT PLAN - LEVEL 2, AREA D-PHASE 1

PL102-P1 PLUMBING - WASTE AND VENT PLAN - LEVEL 2,OVERALL-PHASE 1

PL101D-P1 PLUMBING - WASTE AND VENT PLAN - LEVEL 1, AREA D-PHASE 1

PL101C-P1 PLUMBING - WASTE AND VENT PLAN - LEVEL 1, AREA C-PHASE 1

PL101-P1 PLUMBING - WASTE AND VENT PLAN - LEVEL 1, OVERALL-PHASE 1

PL100D-P1 PLUMBING - WASTE AND VENT PLAN - UNDERGROUND, AREA D-PHASE1

PL100C-P1 PLUMBING - WASTE AND VENT PLAN - UNDERGROUND, AREA C -PHASE1

PL100-P1 PLUMBING - WASTE AND VENT PLAN - UNDERGROUND, OVERALL-PHASE1

PD103-P1 PLUMBING - DEMOLITION - ROOF, OVERALL-PHASE 1

PD102-P1 PLUMBING - DEMOLITION - LEVEL 2,OVERALL-PHASE 1

PD101-P1 PLUMBING - DEMOLITION - LEVEL 1, OVERALL-PHASE 1

PD100-P1 PLUMBING - DEMOLITION - UNDERGROUND, OVERALL-PHASE 1

P-001-P1 PLUMBING - SYMBOLS AND ABBREVIATIONS

PLUMBING

FX902-P1 FIRE SUPPRESSION ISOMETRIC - FINAL - PHASE 1

FX901-P1 FIRE SUPPRESSION ISOMETRIC - EXISTING - PHASE 1

FX503-P1 FIRE SUPPRESSION DETAILS - PHASE 1

FX502-P1 FIRE SUPPRESSION DETAILS - PHASE 1

FX501-P1 FIRE SUPPRESSION DETAILS - PHASE 1

FX401-P1 FIRE SUPPRESSION SECTIONS - PHASE 1

FX103C-P1 FIRE SUPPRESSION PLAN - LEVEL 3, AREA C - PHASE 1

FX103-P1 FIRE SUPPRESSION PLAN - LEVEL 3, OVERALL - PHASE 1

FX102F-P1 FIRE SUPPRESSION PLAN - LEVEL 2, AREA F - PHASE 1

FX102E-P1 FIRE SUPPRESSION PLAN - LEVEL 2, AREA E - PHASE 1

FX102D-P1 FIRE SUPPRESSION PLAN - LEVEL 2, AREA D - PHASE 1

FX102C-P1 FIRE SUPPRESSION PLAN - LEVEL 2, AREA C - PHASE 1

FX102B-P1 FIRE SUPPRESSION PLAN - LEVEL 2, AREA B - PHASE 1

FX102A-P1 FIRE SUPPRESSION PLAN - LEVEL 2, AREA A - PHASE 1

FX102-P1 FIRE SUPPRESSION PLAN - LEVEL 2, OVERALL - PHASE 1

FX101F-P1 FIRE SUPPRESSION PLAN - LEVEL 1, AREA F - PHASE 1

FX101E-P1 FIRE SUPPRESSION PLAN - LEVEL 1, AREA E - PHASE 1

FX101D-P1 FIRE SUPPRESSION PLAN - LEVEL 1, AREA D - PHASE 1

FX101C-P1 FIRE SUPPRESSION PLAN - LEVEL 1, AREA C - PHASE 1

FX101B-P1 FIRE SUPPRESSION PLAN - LEVEL 1, AREA B - PHASE 1

FX101-P1 FIRE SUPPRESSION PLAN - LEVEL 1, OVERALL - PHASE 1

FD112-P1 FIRE SUPPRESSION DEMOLITION PLAN - LEVEL 2, OVERALL - PHASE 1

FD111-P1 FIRE SUPPRESSION DEMOLITION PLAN - LEVEL 1, OVERALL - PHASE 1

FX001-P1 FIRE SUPPRESSION ABBREVIATIONS, SYMBOLS AND GENERAL NOTES - PHASE 1

FA602-P1 FIRE ALARM RISER DIAGRAMS - PHASE 1

FA601-P1 FIRE ALARM MATRIX - PHASE 1

FA502-P1 FIRE ALARM DETAILS - PHASE 1

FA501-P1 FIRE ALARM DETAILS - PHASE 1

FA103C-P1 FIRE ALARM PLAN - LEVEL 3, AREA C - PHASE 1

FA103B-P1 FIRE ALARM PLAN - LEVEL 3, AREA B - PHASE 1

FA103-P1 FIRE ALARM PLAN - LEVEL 3, OVERALL - PHASE 1

FA102E-P1 FIRE ALARM PLAN - LEVEL 2, AREA E - PHASE 1

FA102D-P1 FIRE ALARM PLAN - LEVEL 2, AREA D - PHASE 1

FA102C-P1 FIRE ALARM PLAN - LEVEL 2, AREA C - PHASE 1

FA102B-P1 FIRE ALARM PLAN - LEVEL 2, AREA B - PHASE 1

FA102-P1 FIRE ALARM PLAN - LEVEL 2, OVERALL - PHASE 1

FA101E-P1 FIRE ALARM PLAN - LEVEL 1, AREA E - PHASE 1

FA101D-P1 FIRE ALARM PLAN - LEVEL 1, AREA D - PHASE 1

FA101C-P1 FIRE ALARM PLAN - LEVEL 1, AREA C - PHASE 1

FA101B-P1 FIRE ALARM PLAN - LEVEL 1, AREA B - PHASE 1

FA101-P1 FIRE ALARM PLAN - LEVEL 1, OVERALL - PHASE 1

FD102-P1 FIRE ALARM DEMOLITION PLAN - LEVEL 2, OVERALL - PHASE 1

FD101-P1 FIRE ALARM DEMOLITION PLAN - LEVEL 1, OVERALL - PHASE 1

FA001-P1 FIRE ALARM ABBREVIATIONS, SYMBOLS AND GENERAL NOTES - PHASE 1

FIRE PROTECTION

GI024-P1 GENERAL - INDEX OF DRAWINGS - BID ALTERNATE

GI023-P1 GENERAL - INDEX OF DRAWINGS

GI022-P1 GENERAL - INDEX OF DRAWINGS

GI021-P1 GENERAL - COVER SHEET

GENERAL - VOLUME 1C

AG507-P1 WAYFINDING - SIGN DETAILS - TYPICAL MOUNTING

AG506-P1 WAYFINDING - SIGN DETAILS - SIGN TYPES IPM, GFD, REG

AG505-P1 WAYFINDING - SIGN DETAILS - SIGN TYPES ARA, ARAD, IPS

AG504-P1 WAYFINDING - SIGN DETAILS - SIGN TYPES FIRE, EVAC, GFG1, FEC

AG503-P1 WAYFINDING - SIGN DETAILS - SIGN TYPES RIDI, RIDP, CID, FAC, EXIT, RID, RRP, SID, WID, MRID, IDM.P, SEG

AG502-P1 WAYFINDING - SIGN DETAILS - COLORS, MATERIALS, PICTOGRAMS

AG501-P1 WAYFINDING - SIGN DETAILS - PROJECT TYPOGRAPHY

AG102-P1 WAYFINDING - FLOOR PLAN - LEVEL 2, OVERALL - PHASE 1

AG101-P1 WAYFINDING - FLOOR PLAN - LEVEL 1, OVERALL - PHASE 1

WAYFINDING

Sheet ID Drawing Title

Vincent Hall Drawing Index

G

2 3 4 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

VHALL

J U

N E

W H

N B

-- 1 -3

-0

READY TO ADVERTISE (RTA)

V

IN

C E

N T

H A

L L R

E N

O V

A T

IO

N

P H

A S

E

C:\rvt\2019\10053876-A-VHALL-Central_hdr-alx-rcruz.rvt

7/8/2021 3:17:00 PM

GI033-P1

G E

N E

R A

L

IN

D

E X

O F

D R

A W

IN

G

S

F O

R T

G O

R D

O N

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E N

U E

S A

V A

N N

A H

G

A

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

N T

R A

N

R C

R U

Z

T M

A H

E R

H E

Z Z

E D

D

IN

E

C A

T E

G O

R Y

C O

D E

F Y

P

N

M-871-P1 MECHANICAL - BCS - DETAILS - PHASE 1

M-870-P1 MECHANICAL - BCS - DETAILS - PHASE 1

M-861-P1 MECHANICAL - BCS - CHILLER ROOM VENTILATION CONTROL- PHASE 1

M-860-P1 MECHANICAL - BCS - MISCELLANEOUS CONTROLS- PHASE 1

M-851-P1 MECHANICAL - BCS - HYDROGEN MONITORING SYSTEM POINTS LIST AND SEQUENCE OF OPERATION -...

M-850-P1 MECHANICAL - BCS - HYDROGEN MONITORING SYSTEM DIAGRAM - PHASE 1

M-845-P1 MECHANICAL - BCS - TERMINAL UNIT POINTS AND SEQUENCE OF OPERATIONS - PHASE 1

M-844-P1 MECHANICAL - BCS - TERMINAL UNIT DIAGRAMS - PHASE 1

M-843-P1 MECHANICAL - BCS - HIGH POWERED ROOM CONTROL POINTS AND SEQUENCE OF OPERATIONS- PHASE 1

M-842-P1 MECHANICAL - BCS - HIGH POWERED ROOM CONTROL DIAGRAMS - PHASE 1

M-841-P1 MECHANICAL - BCS - ROOM CONTROL POINTS AND SEQUENCE OF OPERATIONS - PHASE 1

M-840-P1 MECHANICAL - BCS - ROOM CONTROL DIAGRAMS - PHASE 1

M-832-P1 MECHANICAL - BCS - CONDENSER WATER SYSTEM POINTS AND SEQUENCE OF OPERATIONS - PHASE 1

M-831-P1 MECHANICAL - BCS - CONDENSER WATER SYSTEM DIAGRAM B - PHASE 1

M-830-P1 MECHANICAL - BCS - CONDENSER WATER SYSTEM DIAGRAM A - PHASE 1

M-825-P1 MECHANICAL - BCS - CHILLED WATER SYSTEM SEQEUNCE OF OPERATIONS - PHASE 1

M-824-P1 MECHANICAL - BCS - CHILLED WATER SYSTEM POINTS - PHASE 1

M-823-P1 MECHANICAL - BCS - CHILLED WATER DISTRIBUTION - HVAC - PHASE 1

M-822-P1 MECHANICAL - BCS - CHILLED WATER DISTRIBUTION - ACB - PHASE 1

M-821-P1 MECHANICAL - BCS - CHILLED WATER SYSTEM CONTROL DIAGRAM B - PHASE 1

M-820-P1 MECHANICAL - BCS - CHILLED WATER SYSTEM CONTROL DIAGRAM A - PHASE 1

M-815-P1 MECHANICAL - BCS - AHU-3 AND 4 POINTS LIST AND SEQUENCE OF OPERATIONS - PHASE 1

M-814-P1 MECHANICAL - BCS - AHU-3 AND 4 CONTROL - PHASE 1

M-813-P1 MECHANICAL - BCS - DEDICATED OUTSIDE AIR SYSTEM SEQUENCE OF OPERATIONS - PHASE 1

M-812-P1 MECHANICAL - BCS - DEDICATED OUTSIDE AIR SYSTEM POINTS - PHASE 1

M-811-P1 MECHANICAL - BCS - DEDICATED OUTSIDE AIR SYSTEM CONTROL B - PHASE 1

M-810-P1 MECHANICAL - BCS - DEDICATED OUTSIDE AIR SYSTEM CONTROL A - PHASE 1

M-803-P1 MECHANICAL - BCS - SYSTEM ARCHITECTURE DRAWING - PHASE 1

M-802-P1 MECHANICAL - BCS - SYMBOLS AND ABBREVIATIONS (B) - PHASE 1

M-801-P1 MECHANICAL - BCS - SYMBOLS AND ABBREVIATIONS (A) - PHASE 1

M-654-P1 MECHANICAL - SCHEDULES - PHASE 1

M-653-P1 MECHANICAL - SCHEDULES - PHASE 1

M-652-P1 MECHANICAL - SCHEDULES - PHASE 1

M-651-P1 MECHANICAL - SCHEDULES - PHASE 1

M-614-P1 MECHANICAL - FLOW DIAGRAM - CHILLED WATER - DISTRIBUTION - ACB - PHASE 1

M-613-P1 MECHANICAL - FLOW DIAGRAM - CHILLED WATER - DISTRIBUTION - PHASE 1

M-612-P1 MECHANICAL - FLOW DIAGRAM - CHILLED WATER - PHASE 1

M-601-P1 MECHANICAL - FLOW DIAGRAM - AIR - PHASE 1

M-506-P1 MECHANICAL DETAILS - PHASE 1

M-505-P1 MECHANICAL DETAILS - PHASE 1

M-504-P1 MECHANICAL DETAILS - PHASE 1

M-503-P1 MECHANICAL DETAILS - PHASE 1

M-502-P1 MECHANICAL DETAILS - PHASE 1

M-501-P1 MECHANICAL DETAILS - PHASE 1

M-401-P1 MECHANICAL - ENLARGED PLANS - MECHANICAL ROOMS - PHASE 1

MP102E-P1 MECHANICAL PIPING - PLAN - LEVEL 2 - AREA E - PHASE 1

MP102D-P1 MECHANICAL PIPING - PLAN - LEVEL 2 - AREA D - PHASE 1

MP102C-P1 MECHANICAL PIPING - PLAN - LEVEL 2 - AREA C - PHASE 1

MP102B-P1 MECHANICAL PIPING - PLAN - LEVEL 2 - AREA B - PHASE 1

MP101E-P1 MECHANICAL PIPING - PLAN - LEVEL 1 - AREA E - PHASE 1

MP101D-P1 MECHANICAL PIPING - PLAN - LEVEL 1 - AREA D - PHASE 1

MP101C-P1 MECHANICAL PIPING - PLAN - LEVEL 1 - AREA C - PHASE 1

MP101B-P1 MECHANICAL PIPING - PLAN - LEVEL 1 - AREA B - PHASE 1

MH103D-P1 MECHANICAL HVAC/ PIPING - PLAN - ROOF LEVEL - AREA D - PHASE 1

MH103C-P1 MECHANICAL HVAC/ PIPING - PLAN - ROOF LEVEL - AREA C - PHASE 1

MH103B-P1 MECHANICAL HVAC/ PIPING - PLAN - ROOF LEVEL - AREA B - PHASE 1

MH102E-P1 MECHANICAL HVAC - PLAN - LEVEL 2 - AREA E - PHASE 1

MH102D-P1 MECHANICAL HVAC - PLAN - LEVEL 2 - AREA D - PHASE 1

MH102C-P1 MECHANICAL HVAC - PLAN - LEVEL 2 - AREA C - PHASE 1

MH102B-P1 MECHANICAL HVAC - PLAN - LEVEL 2 - AREA B - PHASE 1

MH101E-P1 MECHANICAL HVAC - PLAN - LEVEL 1 - AREA E - PHASE 1

MH101D-P1 MECHANICAL HVAC - PLAN - LEVEL 1 - AREA D - PHASE 1

MH101C-P1 MECHANICAL HVAC - PLAN - LEVEL 1 - AREA C - PHASE 1

MH101B-P1 MECHANICAL HVAC - PLAN - LEVEL 1 - AREA B - PHASE 1

M-103-P1 MECHANICAL - PLAN - ROOF LEVEL - OVERALL - PHASE 1

M-102-P1 MECHANICAL - PLAN - LEVEL 2 - OVERALL - PHASE 1

M-101-P1 MECHANICAL - PLAN - LEVEL 1 - OVERALL - PHASE 1

MD402-P1 MECHANICAL DEMOLITION ENLARGED PLANS - PHASE 1

MD401-P1 MECHANICAL DEMOLITION ENLARGED PLANS - PHASE 1

MD103-P1 MECHANICAL DEMOLITION - PLAN - ROOF LEVEL - OVERALL - PHASE 1

MD102-P1 MECHANICAL DEMOLITION - PLAN - LEVEL 2 - OVERALL - PHASE 1

MD101-P1 MECHANICAL DEMOLITION - PLAN - LEVEL 1 - OVERALL - PHASE 1

M-002-P1 MECHANICAL SCOPE DIAGRAMS - PHASE 1

M-001-P1 MECHANICAL SYMBOLS AND ABBREVIATIONS - PHASE 1

MECHANICAL

Sheet ID Drawing Title

Vincent Hall Drawing Index

E-651-P1 ELECTRICAL - RECEPTACLE RELAY PANEL SCHEDULE

E-619-P1 ELECTRICAL PANEL SCHEDULES

E-618-P1 ELECTRICAL PANEL SCHEDULES

E-617-P1 ELECTRICAL PANEL SCHEDULES

E-616-P1 ELECTRICAL PANEL SCHEDULES

E-615-P1 ELECTRICAL PANEL SCHEDULES

E-614-P1 ELECTRICAL PANEL SCHEDULES

E-613-P1 ELECTRICAL PANEL SCHEDULES

E-612-P1 ELECTRICAL PANEL SCHEDULES

E-611-P1 ELECTRICAL PANEL SCHEDULES

E-610-P1 ELECTRICAL PANEL SCHEDULES

E-609-P1 ELECTRICAL PANEL SCHEDULES

E-608-P1 ELECTRICAL PANEL SCHEDULES

E-607-P1 ELECTRICAL PANEL SCHEDULES

E-606-P1 ELECTRICAL TRANSFORMER AND FEEDER SCHEDULES

E-605-P1 ELECTRICAL GROUNDING RISER PLAN - PHASE 1

E-604-P1 ELECTRICAL ONE-LINE DIAGRAM - PHASE 1

E-603-P1 ELECTRICAL ONE-LINE DIAGRAM - PHASE 1

E-602-P1 ELECTRICAL ONE-LINE DIAGRAM - PHASE 1

E-601-P1 ELECTRICAL ONE-LINE DIAGRAM - PHASE 1

ED601-P1 ELECTRICAL ONE-LINE DIAGRAM DEMOLITION - PHASE 1

E-502-P1 ELECTRICAL - DETAILS

E-501-P1 ELECTRICAL - DETAILS

E-404-P1 ELECTRICAL ENLARGED PLANS - PHASE 1

E-403-P1 ELECTRICAL ENLARGED PLANS - PHASE 1

E-402-P1 ELECTRICAL ENLARGED PLANS - PHASE 1

E-401-P1 ELECTRICAL ENLARGED PLANS - PHASE 1

EP103D-P1 ELECTRICAL - POWER PLAN - ROOF LEVEL - AREA D - PHASE 1

EP103C-P1 ELECTRICAL - POWER PLAN - ROOF LEVEL - AREA C - PHASE 1

EP103B-P1 ELECTRICAL - POWER PLAN - ROOF LEVEL - AREA B - PHASE 1

EP102E-P1 ELECTRICAL - POWER PLAN - LEVEL 2 - AREA E - PHASE 1

EP102D-P1 ELECTRICAL - POWER PLAN - LEVEL 2 - AREA D - PHASE 1

EP102C-P1 ELECTRICAL - POWER PLAN - LEVEL 2 - AREA C - PHASE 1

EP102B-P1 ELECTRICAL - POWER PLAN - LEVEL 2 - AREA B - PHASE 1

EP102-P1 OVERALL ELECTRICAL PLAN - LEVEL 2 - PHASE 1

EP101E-P1 ELECTRICAL - POWER PLAN - LEVEL 1 - AREA E - PHASE 1

EP101D-P1 ELECTRICAL - POWER PLAN - LEVEL 1 - AREA D - PHASE 1

EP101C-P1 ELECTRICAL - POWER PLAN - LEVEL 1 - AREA C - PHASE 1

EP101B-P1 ELECTRICAL - POWER PLAN - LEVEL 1 - AREA B - PHASE 1

EP101-P1 OVERALL ELECTRICAL PLAN - LEVEL 1 - PHASE 1

EG103-P1 OVERALL ELECTRICAL GROUNDING PLAN - ROOF LEVEL - PHASE 1

EG102-P1 OVERALL ELECTRICAL GROUNDING PLAN - LEVEL 2 - PHASE 1

EG101-P1 OVERALL ELECTRICAL GROUNDING PLAN - LEVEL 1 - PHASE 1

EL630-P1 ELECTRICAL - LIGHTING FIXTURE SCHEDULE

EL604-P1 ELECTRICAL - LIGHTING FIXTURE SCHEDULE

EL603-P1 ELECTRICAL - LIGHTING CONTROL MATRIX

EL602-P1 ELECTRICAL - LIGHTING CONTROL DETAILS

EL601-P1 ELECTRICAL - LIGHTING CONTROL DETAILS

EL502-P1 ELECTRICAL - LIGHTING FIXTURE DETAILS

EL501-P1 ELECTRICAL - LIGHTING FIXTURE DETAILS

EL401-P1 ELECTRICAL - STAIR SECTION

EL103C-P1 ELECTRICAL - LIGHTING PLAN - ROOF LEVEL - AREA C - PHASE 1

EL102E-P1 ELECTRICAL - LIGHTING PLAN - LEVEL 2 - AREA E - PHASE 1

EL102D-P1 ELECTRICAL - LIGHTING PLAN - LEVEL 2 - AREA D - PHASE 1

EL102C-P1 ELECTRICAL - LIGHTING PLAN - LEVEL 2 - AREA C - PHASE 1

EL102B-P1 ELECTRICAL - LIGHTING PLAN - LEVEL 2 - AREA B - PHASE 1

EL102-P1 OVERALL ELECTRICAL LIGHTING PLAN - LEVEL 2 - PHASE 1

EL101E-P1 ELECTRICAL - LIGHTING PLAN - LEVEL 1 - AREA E - PHASE 1

EL101D-P1 ELECTRICAL - LIGHTING PLAN - LEVEL 1 - AREA D - PHASE 1

EL101C-P1 ELECTRICAL - LIGHTING PLAN - LEVEL 1 - AREA C - PHASE 1

EL101B-P1 ELECTRICAL - LIGHTING PLAN - LEVEL 1 - AREA B - PHASE 1

EL101-P1 OVERALL ELECTRICAL LIGHTING PLAN - LEVEL 1 - PHASE 1

ED102-P1 OVERALL ELECTRICAL DEMOLITION PLAN - LEVEL 2 - PHASE 1

ED101-P1 OVERALL ELECTRICAL DEMOLITION PLAN - LEVEL 1 - PHASE 1

ES101-P1 ELECTRICAL - POWER SITE PLAN

E-002-P1 ELECTRICAL GENERAL NOTES

E-001-P1 ELECTRICAL SYMBOLS AND ABBREVIATIONS

ELECTRICAL

GI034-P1 GENERAL - INDEX OF DRAWINGS - BID ALTERNATE

GI033-P1 GENERAL - INDEX OF DRAWINGS

GI032-P1 GENERAL - INDEX OF DRAWINGS

GI031-P1 GENERAL - COVER SHEET

GENERAL - VOLUME 1D

Sheet ID Drawing Title

Vincent Hall Drawing Index

TA401-P1 AUDIO VISUAL - ELEVATIONS

TA202D-P1 AUDIO VISUAL - REFLECTED CEILING PLAN - LEVEL 2, AREA D - PHASE 1

TA202C-P1 AUDIO VISUAL - REFLECTED CEILING PLAN - LEVEL 2, AREA C - PHASE 1

TA202B-P1 AUDIO VISUAL - REFLECTED CEILING PLAN - LEVEL 2, AREA B - PHASE 1

TA202-P1 AUDIO VISUAL - REFLECTED CEILING PLAN - LEVEL 2, OVERALL - PHASE 1

TA201C-P1 AUDIO VISUAL - REFLECTED CEILING PLAN - LEVEL 1, AREA C - PHASE 1

TA201B-P1 AUDIO VISUAL - REFLECTED CEILING PLAN - LEVEL 1, AREA B - PHASE 1

TA201-P1 AUDIO VISUAL - REFLECTED CEILING PLAN - LEVEL 1, OVERALL - PHASE 1

TA102D-P1 AUDIO VISUAL - FLOOR PLAN - LEVEL 2, AREA D - PHASE 1

TA102C-P1 AUDIO VISUAL - FLOOR PLAN - LEVEL 2, AREA C - PHASE 1

TA102B-P1 AUDIO VISUAL - FLOOR PLAN - LEVEL 2, AREA B - PHASE 1

TA102-P1 AUDIO VISUAL - FLOOR PLAN - LEVEL 2, OVERALL - PHASE 1

TA101C-P1 AUDIO VISUAL - FLOOR PLAN - LEVEL 1, AREA C - PHASE 1

TA101B-P1 AUDIO VISUAL - FLOOR PLAN - LEVEL 1, AREA B - PHASE 1

TA101-P1 AUDIO VISUAL - FLOOR PLAN - LEVEL 1, OVERALL - PHASE 1

TA041-P1 AUDIO VISUAL - GENERAL NOTES AND SYMBOLS LEGEND

AUDIO VISUAL

TY602-P1 SECURITY - RISER DIAGRAM - PHASE 1

TY601-P1 SECURITY - RISER DIAGRAM - PHASE 1

TY502-P1 SECURITY - DETAILS - PHASE 1

TY501-P1 SECURITY - DETAILS - PHASE 1

TY102E-P1 SECURITY - FLOOR PLAN - LEVEL 2, AREA E - PHASE 1

TY102D-P1 SECURITY - FLOOR PLAN - LEVEL 2, AREA D - PHASE 1

TY102C-P1 SECURITY - FLOOR PLAN - LEVEL 2, AREA C - PHASE 1

TY102B-P1 SECURITY - FLOOR PLAN - LEVEL 2, AREA B - PHASE 1

TY102-P1 SECURITY - FLOOR PLAN - LEVEL 2, OVERALL - PHASE 1

TY101E-P1 SECURITY - FLOOR PLAN - LEVEL 1, AREA E - PHASE 1

TY101D-P1 SECURITY - FLOOR PLAN - LEVEL 1, AREA D - PHASE 1

TY101C-P1 SECURITY - FLOOR PLAN - LEVEL 1, AREA C - PHASE 1

TY101B-P1 SECURITY - FLOOR PLAN - LEVEL 1, AREA B - PHASE 1

TY101-P1 SECURITY - FLOOR PLAN - LEVEL 1, OVERALL - PHASE 1

TD112-P1 SECURITY - DEMOLITION PLAN - LEVEL 2 - OVERALL -PHASE 1

TD111-P1 SECURITY - DEMOLITION PLAN - LEVEL 1 - OVERALL -PHASE 1

TY001-P1 SECURITY - GENERAL NOTES AND SYMBOL LEGEND - PHASE 1

SECURITY

T-603-P1 TELECOMMUNICATIONS - COPPER BACKBONE RISER DIAGRAM - PHASE 1

T-602-P1 TELECOMMUNICATIONS - FIBER OPTIC BACKBONE RISER DIAGRAM - PHASE 1

T-601-P1 TELECOMMUNICATIONS - CONDUIT RISER DIAGRAM - PHASE 1

T-505-P1 TELECOMMUNICATIONS - DETAILS - PHASE 1

T-504-P1 TELECOMMUNICATIONS - DETAILS - PHASE 1

T-503-P1 TELECOMMUNICATIONS - DETAILS - PHASE 1

T-502-P1 TELECOMMUNICATIONS - DETAILS - PHASE 1

T-501-P1 TELECOMMUNICATIONS - DETAILS - PHASE 1

T-401-P1 TELECOMMUNICATIONS - ENLARGED PLANS - PHASE 1

T-103C-P1 TELECOMMUNICATIONS - ROOF PLAN - AREA C - PHASE 1

T-103-P1 TELECOMMUNICATIONS - ROOF PLAN - OVERALL - PHASE 1

T-102E-P1 TELECOMMUNICATIONS - FLOOR PLAN - LEVEL 2, AREA E - PHASE 1

T-102D-P1 TELECOMMUNICATIONS - FLOOR PLAN - LEVEL 2, AREA D - PHASE 1

T-102C-P1 TELECOMMUNICATIONS - FLOOR PLAN - LEVEL 2, AREA C - PHASE 1

T-102B-P1 TELECOMMUNICATIONS - FLOOR PLAN - LEVEL 2, AREA B - PHASE 1

T-102-P1 TELECOMMUNICATIONS - FLOOR PLAN - LEVEL 2, OVERALL - PHASE 1

T-101E-P1 TELECOMMUNICATIONS - FLOOR PLAN - LEVEL 1, AREA E - PHASE 1

T-101D-P1 TELECOMMUNICATIONS - FLOOR PLAN - LEVEL 1, AREA D - PHASE 1

T-101C-P1 TELECOMMUNICATIONS - FLOOR PLAN - LEVEL 1, AREA C - PHASE 1

T-101B-P1 TELECOMMUNICATIONS - FLOOR PLAN - LEVEL 1, AREA B - PHASE 1

T-101-P1 TELECOMMUNICATIONS - FLOOR PLAN - LEVEL 1, OVERALL - PHASE 1

TD102-P1 TELECOMMUNICATIONS - DEMOLITION PLAN - LEVEL 2 - OVERALL -PHASE 1

TD101-P1 TELECOMMUNICATIONS - DEMOLITION PLAN - LEVEL 1 - OVERALL -PHASE 1

T-100-P1 TELECOMMUNICATIONS - SITE PLAN - PHASE 1

T-001-P1 TELECOMMUNICATIONS - GENERAL NOTES AND SYMBOLS LEGEND - PHASE 1

TELECOMMUNICATIONS

G

2 3 4 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

VHALL

J U

N E

W H

N B

-- 1 -3

-0

READY TO ADVERTISE (RTA)

V

IN

C E

N T

H A

L L R

E N

O V

A T

IO

N

P H

A S

E

C:\rvt\2019\10053876-A-VHALL-Central_hdr-alx-rcruz.rvt

7/8/2021 3:17:07 PM

GI034-P1

G E

N E

R A

L

IN

D

E X

O F

D R

A W

IN

G

S

B

ID

A L T

E R

N A

T E

F O

R T

G O

R D

O N

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E N

U E

S A

V A

N N

A H

G

A

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

N T

R A

N

R C

R U

Z

T M

A H

E R

H E

Z Z

E D

D

IN

E

C A

T E

G O

R Y

C O

D E

F Y

P

N

EL704C-P1 ELECTRICAL - LIGHTING PLAN - LEVEL 2 - AREA C - PHASE 1 - ALT #1

EL704B-P1 ELECTRICAL - LIGHTING PLAN - LEVEL 2 - AREA B - PHASE 1 - ALT #1

ELECTRICAL

A-705-P1 ARCHITECTURAL - UPFOLDING PARTITION DETAILS - PHASE 1 - BID ALT #1

A-704C-P1 ARCHITECTURAL - REFLECTED CEILING PLAN - LEVEL 2, AREA C - PHASE 1 - BID ALT #1

A-704B-P1 ARCHITECTURAL - REFLECTED CEILING PLAN - LEVEL 2, AREA B - PHASE 1 - BID ALT #1

A-702C-P1 ARCHITECTURAL - FLOOR PLAN - LEVEL 2, AREA C - PHASE 1 - BID ALT #1

A-702B-P1 ARCHITECTURAL - FLOOR PLAN - LEVEL 2, AREA B - PHASE 1 - BID ALT #1

ARCHITECTURE

S-710-P1 STRUCTURAL - STEEL - TYPICAL DETAILS - BID ALT #1

SF703C-P1 STRUCTURAL - FRAMING PLAN - ROOF, AREA C - PHASE 1 - BID ALT #1

SF703B-P1 STRUCTURAL - FRAMING PLAN - ROOF, AREA B - PHASE 1 - BID ALT #1

STRUCTURAL

GI042-P1 GENERAL - INDEX OF DRAWINGS - BID ALTERNATE

GI041-P1 GENERAL - COVER SHEET - BID ALTERNATE

GENERAL - VOLUME 1E - BID ALTERNATE

PARAPET MOUNTED AIR TERMINAL REFER TO DETAILS.

SCREEN WALL MOUNTED AIR TERMINAL REFER TO DETAILS.

FLAT ROOF MOUNTED AIR TERMINAL REFER TO DETAILS.

THRU ROOF DOWN CONDUCTOR TO GROUNDING ELECTRODE

MAIN CONDUCTOR

SECONDARY CONDUCTOR

BONDING CONNECTION

GROUND CONDUCTOR

COPPER GROUND ROD 3/4"DIA. X 10'-0" LONG

G

S

P

PS

GENERAL

LIGHTNING PROTECTION

G

KWHD

GFI

GFP

GRA

ALT

VM

AM

WM

FM

DM

HHMH

TEL

PRI

P

SEC

A

NOTES:

1. MULTI-CIRCUIT RACEWAYS SHALL BE ALTERNATELY CIRCUITED. LABEL ALL RECEPTACLES WITH PANEL NAME

AND CIRCUIT NUMBER.

B

C

ONE DUPLEX CONVENIENCE RECEPTACLE, 125 VOLTS, 20 AMP,

GROUNDING TYPE

ONE QUAD CONVENIENCE RECEPTACLE, 125 VOLTS, 20 AMP,

GROUNDING TYPE AND ONE VOICE/DATA OUTLET

ONE DUPLEX CONVENIENCE RECEPTACLE, 125 VOLTS, 20 AMP,

GROUNDING TYPE

ONE DUPLEX CONVENIENCE RECEPTACLE, 125 VOLTS, 20 AMP,

GROUNDING TYPE AND ONE VOICE/DATA OUTLET

DESCRIPTIONSYMBOL

FLUSH FLOOR BOX/POKE-THRU SCHEDULE

REMARKS

A

B

A

B

WIREMOLD SERIES G-3000

WIREMOLD SERIES G-4000

WIREMOLD SERIES G-6000

2'-0"

2'-0"

2'-0"

NA

PLANS

AS SHOWN

AS SHOWN

PLANS

REMARKS

TELE/DATA

OUTLET CENTERS

POWER

DESCRIPTION

MULTIOUTLET ASSEMBLY SCHEDULE

TYPE

A

B

SYMBOL

NEMA

CONFIGURATION

WIRE/CONDUIT

(UON)

VOLTAGE

RATING

C.B. OR FUSE

AMPS/POLES

REMARKS

2#12 & 1#12G-3/4"C

2#10 & 1#10G-3/4"C

250V

250V

20/2

30/2

L6-20R

L6-30R

SPECIAL OUTLETS SCHEDULE

EPO

T-1 T15

XX

XX

T

30/3

30/6

30/3

20AF

30/3

XX

XX

A

B

PDM

A1,3,5

1LN1PANEL NAME

CIRCUIT NUMBER(S)

CIRCUIT NUMBER(S)

PANEL NAME

NPL1E1-1

800A 3P

800AF

800AT

3P

XXXXAF XXXXAT 3P

6A

12x3

CP

T

AS

VS

WS

C

VFD

RC

A

JJ

J

J

M

BRANCH CIRCUIT HOMERUN. PROVIDE #12 PHASE, #12 NEUTRAL

AND #12 GROUND CONDUCTORS FOR EACH INDICATED CIRCUIT

OR

MULTI WIRE BRANCH U.O.N. PROVIDE SWITCH LEGS FOR SWITCH

CIRCUITING AS REQUIRED. PROVIDE EQUIPMENT GROUND WIRE

IN

ALL BRANCH CIRCUIT RACEWAYS. PROVIDE SEPARATE

ISOLATED

GROUND WIRE TO ALL ISOLATED GROUND DEVICES.

CONDUIT RISER UP

CONDUIT RISER DOWN

INDICATES CIRCUIT CONTINUATION

STUB INTO ACCESSIBLE CORRIDOR CEILING SPACE UNLESS

OTHERWISE NOTED

CONDUIT SEAL FITTING FOR HAZARDOUS AREAS

CONDUIT SLEEVE

CAP END OF CONDUIT

TYPICAL OUTLET SYMBOL NOTES

"*" -MOUNTED 4" ABOVE COUNTER, CASEWORK, BACKSPLASH OR 46" IF NOTHING BELOW.

COORDINATE WITH ARCHITECTURAL DETAILS AND CASEWORK CONTRACTOR.

"+84" -INDICATES MOUNTING HEIGHT ABOVE FINISHED FLOOR.

"GFI" -GROUND FAULT CIRCUIT INTERRUPTER.

"ST" -SAFETY TYPE

"IG" -ISOLATED GROUND

"WP" -WEATHERPROOF

"XP" -EXPLOSION PROOF

"SW" -TOP HALF OF DUPLEX RECEPTACLE SWITCHED

"CL" -CLOCK RECEPTACLE

480/277V OR 480V PANEL

208/120V PANEL

120/240V PANEL

RELAY PANEL

COMBINATION FULL VOLTAGE MOTOR STARTER

REV = REVERSING

COMBINATION FULL VOLTAGE MOTOR STARTER / DISCONNECT

REV = REVERSING

VARIABLE FREQUENCY DRIVE

JUNCTION BOX, MOUNTED ABOVE CEILING IN AREAS WITH

SUSPENDED CEILING, MOUNTED EXPOSED IN AREAS WITH NO

SUSPENDED CEILING

JUNCTION BOX WITH FLEXIBLE CONNECTION TO EQUIPMENT

INDICATED AND REQUIRED

JUNCTION BOX, FLUSH WALL MOUNTED

T = JUNCTION BOX FOR VOICE/DATA

BUS DUCT, FEEDER OR PLUG-IN TYPE AS INDICATED

20A, 125V, 2 POLE, 3 WIRE GROUNDING DUPLEX RECEPTACLE, RED

20A, 125V, 2 POLE, 3 WIRE GROUNDING SINGLE RECEPTACLE

20A, 125V, 2 POLE, 3 WIRE GROUNDING SINGLE RECEPTACLE, RED

20A, 125V, 2 POLE, 3 WIRE GROUNDING DOUBLE DUPLEX RECEPTACLE

20A, 125V, 2 POLE, 3 WIRE GROUNDING DOUBLE DUPLEX RECEPTACLE, RED

PEDESTAL - BENCH MOUNTED BACK-TO-BACK DUPLEX

CONVENIENCE RECEPTACLE.

PEDESTAL - BENCH MOUNTED DUPLEX CONVENIENCE RECEPTACLE.

PEDESTAL - BENCH MOUNTED BACK-TO-BACK DOUBLE DUPLEX

CONVENIENCE RECEPTACLE

PEDESTAL - BENCH MOUNTED DOUBLE DUPLEX

CONVENIENCE RECEPTACLE.

SPECIAL OUTLET. REFER TO SCHEDULE FOR REQUIREMENTS.

20A, 125V, 2 POLE, 3 WIRE GROUNDING DOUBLE DUPLEX RECEPTACLE.

SPECIAL PURPOSE I.E. UPS

20A, 125V, 2 POLE, 3 WIRE GROUNDING DUPLEX RECEPTACLE.

SPECIAL PURPOSE I.E. UPS

POWER DISTRIBUTION MODULE UNDER ACCESS

RAISED FLOOR

POKE THROUGH - REFER TO SCHEDULE FOR REQUIREMENTS

ONE PREWIRED DUPLEX RECEPTACLE, 125 VOLTS, 20 AMP. MOUNTED IN CAST

BOX SUPPLIED WITH CABLE BY COMPUTER POWER CENTER MANUFACTURER.

INSTALLED UNDER RAISED FLOOR. REFER TO COMPUTER ROOM EQUIPMENT

SCHEDULE.

TWO PREWIRED DUPLEX RECEPTACLES (QUAD), 125 VOLTS, 20 AMP. MOUNTED

IN CAST BOX SUPPLIED WITH CABLE BY COMPUTER POWER CENTER

MANUFACTURER. INSTALLED UNDER RAISED FLOOR. REFER TO COMPUTER

ROOM EQUIPMENT SCHEDULE.

SPECIAL PURPOSE PREWIRED RECEPTACLE OR CONNECTOR AS INDICATED IN

COMPUTER ROOM EQUIPMENT SCHEDULES, SUPPLIED WITH CABLE BY

COMPUTER POWER CENTER MANUFACTURER. INSTALLED UNDER RAISED

FLOOR BY E.C.

MULTIOUTLET ASSEMBLY, - INDICATES TYPE, - INDICATES QUANTITY OF

DUPLEX RECEPTACLES. SEE MULTIOUTLET ASSEMBLY SCHEDULE. SEE DETAIL

DRAWINGS FOR INSTALLATION REQUIREMENTS.

POWER / TELECOMM POLE. PROVIDE JUNCTION BOX ABOVE CEILING FOR

POWER CONNECTION, CONNECT TO WIRING IN POWER POLE. SEE SCHEDULE

EXTENSION CORD REEL

EMERGENCY POWER OFF' BREAK GLASS STATION.

GROUND ROD AND SYSTEM TEST WELL

GROUND ROD CONNECTION

ELECTRICAL MANHOLE OR HANDHOLE

MH=MANHOLE, HH=HANDHOLE

COMBINED POWER AND TELEPHONE UTILITY POLE

GROUND BUS ON STANDOFFS

EXOTHERMIC COMPRESSION CONNECTION

CIRCUIT BREAKER. AMP/POLES AS INDICATED

FUSE. SIZE AS INDICATED

FUSIBLE SWITCH. AMP/POLES/FUSE SIZE AS INDICATED

AUTOMATIC TRANSFER SWITCH

TRANSFORMER - SEE SCHEDULE FOR REQUIREMENTS

GROUND CONNECTION

GENERATOR

AMMETER PHASE SELECTOR SWITCH

VOLTMETER PHASE SELECTOR SWITCH

WATTMETER ON-OFF SWITCH

A.C. VOLTMETER

A.C. AMMETER

WATTMETER

FREQUENCY METER

DIGITAL METERING

KILOWATT HOUR/DEMAND METER

GENERATOR GROUND FAULT INDICATION

GROUND FAULT PROTECTION

CURRENT TRANSFORMER

POTENTIAL TRANSFORMER

GENERATOR REMOTE ANNUNCIATOR

ALTERNATOR FURNISHED BY OTHER THAN DIVISION 26

DISCONNECT SWITCH. SIZE AS INDICATED

MEDIUM VOLTAGE DRAWOUT CIRCUIT BREAKER.

LOW VOLTAGE DRAWOUT CIRCUIT BREAKER.

LIGHTNING ARRESTERS

CONDUIT RUN BELOW GRADE, UNDER OR CONCEALED IN FLOOR

SLAB, UNDER RAISED FLOOR

TYPICAL OUTLET SYMBOL CIRCUITING NOTES

NOTES

1. OUTLETS LOCATED AT COUNTERS SHALL BE LOCATED 18" AFF IN KNEE SPACE IF PROVIDED

OR 4" ABOVE COUNTER OR BACK SPLASH AS APPLICABLE IF NO KNEE SPACE IS PROVIDED

UON.

SYSTEM CIRCUIT. SUBSCRIPT "XX" DENOTES SYSTEM TYPE

CONDUIT TO TERMINAL CABINET. SUBSCRIPT "XX" DENOTES

SYSTEM TYPE

XXX

3 LA'S

SECONDARY UNDERGROUND ELECTRICAL CONDUIT AND WIRING

UNDERGROUND TELEPHONE CONDUIT

CIRCUIT DESIGNATIONS

SITE EXTERIOR

UNDERGROUND CONDUIT AND WIRING

POWER OUTLETS

20A, 125V, 2 POLE, 3 WIRE GROUNDING DUPLEX RECEPTACLE

CEILING MOUNTED RECEPTACLE, TYPE AS INDICATED ABOVE

GF

+30"

POWER DISTRIBUTION

DISCONNECT SWITCH

6 POLE DISCONNECT SWITCH (FOR ALL 2 SPEED MOTORS)

FUSED DISCONNECT SWITCH

MANUAL MOTOR STARTER SWITCH WITH THERMAL OVERLOAD

PROTECTION.

CONTACTOR

ENCLOSED CIRCUIT BREAKER

COMBINATION REDUCED VOLTAGE MOTOR STARTER

COMBINATION REDUCED VOLTAGE MOTOR STARTER/DISCONNECT

COMBINATION 2 SPEED MOTOR STARTER/DISCONNECT

MOTOR - NUMBER INDICATES HORSEPOWER

2 SPEED MOTOR - NUMBER INDICATES HORSEPOWER

CONTROL PANEL FURNISHED BY OTHERS, INSTALLED BY

DIVISION 26, UON

PUSHBUTTON STATIONS. ONE, TWO, OR THREE AS INDICATED

CABLE TRAY - WIDTH x HEIGHT AS NOTED, OR KEY NOTED

UNDER FLOOR DUCT SYSTEM

DRY TYPE TRANSFORMER

POWER ONE-LINE DIAGRAM

CONDUIT RUN CONCEALED IN CEILING OR WALL

SITE POWER AND TELECOMMUNICATIONS

PANEL NAME

CIRCUIT NUMBER

ELEVATION

TYPE

LP-1

GF

+30"

PANEL NAME

CIRCUIT NUMBER

ELEVATION

TYPE

LP-1

1,3,5

XXXX-XXXX

XXXX-XXXX

J TV

POWER SUPPLY

EMERGENCY POWER OFFEPO

REMOTE CONTROL

TEMPERATURE CONTROL

CLOSED CIRCUIT TELEVISIONCCTV

GROUNDING ELECTRODE CONDUCTOR

SECURITYSEC

TELEVISION

TELEPHONE

PUBLIC ADDRESS SYSTEM

INTRUSION DETECTION

DOOR CONTROL

INTERCOM

FIRE ALARM

DATA TECHNOLOGY

THE FOLLOWING SUBSCRIPTS ARE USED TO INDICATE

DIFFERENT SYSTEM TYPES

FOOT ON DEVICE INDICATES WALL MOUNTED

MARK NUMBER FOR FIXED EQUIPMENT

MARK NUMBER FOR MECHANICAL EQUIPMENT

KEY NOTE REFERENCE SYMBOL.

RC

TC

G

TV

TEL

PA

ID

DC

IC

FA

DT

PRIMARY UNDERGROUND ELECTRICAL CONDUIT AND WIRING

UNDERGROUND POWER ELECTRICAL CONDUIT AND WIRING

SHUNT TRIP

NOTE:

SYMBOLS SHOWN ARE FOR REFERENCE ONLY AND DO

NOT CONSTITUTE A CHECK LIST OF DEVICES REQUIRED

BY THE CONTRACT

TELECOMMUNICATION SECONDARY BONDING BUSBAR

ELECTRICAL GROUNDING BUSBAR DESIGNATION

TELECOMMUNICATION PRIMARY BONDING BUSBAR

MAIN ELECTRICAL GROUNDING BUSBAR DESIGNATION

GROUNDING

SBB

EGB

PBB

MEGB

EXOTHERMIC WELD

#4/0 COPPER, UON.

EQUIPMENT MOUNTED AIR TERMINAL REFER TO DETAILS.E

SITE LIGHTING FIXTURE DESCRIPTIONS

POLE MOUNTED SINGLE ARM LUMINAIRE

POLE MOUNTED TWIN ARM LUMINAIRE

POLE MOUNTED TRIPLE ARM LUMINAIRE

POLE MOUNTED QUAD ARM LUMINAIRE

POLE MOUNTED POST TOP LUMINAIRE

GENERAL LIGHTING FIXTURE NORMAL AND EMERGENCY BRANCH DESIGNATIONS (TYPICAL

FOR ALL LIGHTING FIXTURES)

LUMINAIRE CONNECTED TO NORMAL BRANCH

LUMINAIRE CONNECTED TO EMERGENCY EGRESS / NIGHT LIGHT / LIFE

SAFETY BRANCH CIRCUIT

LIGHTING FIXTURE DESCRIPTIONS

RECESSED OR SURFACE MOUNTED LUMINAIRE TROFFER (SIZE

CHANGES AS SHOWN ON PLANS FOR 2'X4' , 1'X4' OR 2'x2' - REFER

TO FIXTURE PLATES FOR SIZE INFORMATION AND OTHER SIZES)

RECESSED OR SURFACE MOUNTED SQUARE DOWNLIGHT LUMINAIRE

• DENOTES WALL WASHER AND DIRECTION OF LIGHT DISTRIBUTION

STRIP OR TURRET LUMINAIRE, SURFACE MOUNTED (LENGTH AS

SHOWN ON PLANS)

LINEAR LUMINAIRE, PENDANT MOUNTED (LENGTH AS SHOWN ON

PLANS)

CHANDELIER, PENDANT MOUNTED (DIAMETER AS SHOWN ON PLANS)

EXIT SIGN

• INDICATES DIRECTIONAL CHEVRON(S)

• DENOTES LOCATION(S) OF ILLUMINATED EXIT FACE

EMERGENCY TWIN HEAD FLOOD LIGHTING UNIT WITH INTEGRAL

BATTERY PACK

EMERGENCY TWIN HEAD FLOOD LIGHTING UNIT WITH REMOTE

BATTERY PACK

EMERGENCY SINGLE HEAD FLOOD LIGHTING UNIT WITH REMOTE

BATTERY PACK

WALL MOUNTED LUMINAIRE

LIGHTING

L3 a

GENERAL LIGHTING FIXTURE DESIGNATIONS (TYPICAL FOR ALL LIGHTING FIXTURES)

LUMINAIRE TYPE.

"#" INDICATES NORMAL OR EMERGENCY CIRCUIT NUMBER

SWITCHING CONTROL ZONE

· SINGLE LOWER CASE LETTER SUBSCRIPT MATCHES DESIGNATION

OF CORRESPONDING SWITCHING CONTROL DEVICE

NOTE: LUMINAIRE TYPE AND CIRCUIT NUMBER INDICATED \ AT A CONTINUOUS ROW OF

FIXTURES SHALL BE CONSIDERED TO BE TYPICAL FOR ALL FIXTURES IN THAT ROW.

UNLESS NOTED OTHERWISE.

TWO LETTERS INDICATES LOW VOLTAGE RELAY ZONE·

DS

OS

a a

SWITCHES - WALL MOUNTED AT 48" AFF

SWITCH

TYPE DESIGNATION:

LV3 - LOW VOLTAGE 3 BUTTON SWITCH WITH RAISE/LOWER FEATURES

LV5 - LOW VOLTAGE 5 BUTTON PROGRAMMABLE SWITCH

LV - LOW VOLTAGE 2 BUTTON SWITCH FOR ON/OFF

OS - VACANCY SENSOR

3 - 3 WAY SWITCH

4 - 4 WAY SWITCH

a - LUMINAIRE CONTROL DESIGNATION

SENSOR TYPE DESIGNATION

a - LUMINAIRE CONTROL DESIGNATION

LOW VOLTAGE DEVICES - CEILING MOUNTED

OCCUPANCY SENSOR

a

SENSOR TYPE DESIGNATION

a - LUMINAIRE CONTROL DESIGNATION

DAY LIGHT SENSOR

2'x2' TROFFER

LINEAR UNDERCABINET LUMINAIRE (LENGTH AS SHOWN ON PLANS)

LIGHTING SWITCHING DESIGNATIONS

(OCCUPANCY AND PHOTO SENSORS INDICATED ON PLANS ARE DIAGRAMMATIC.

CONTRACTOR SHALL PROVIDE NUMBER AND PLACEMENT OF SENSORS TO AVOID

INTERFERENCE WITH OTHER SYSTEMS AND ENSURE PROPER COVERAGE AND OPERATION

OF LIGHTING CONTROLS IN THE CONTROLLED AREA)

#4/0 UNDERGROUND GROUNDING COPPERG

WORKSTATION POWER MODULE (WPM) WITH (4) DUPLEX RECEPTACLES

(2) RECEPTACLES NOT CONTROLLED AND 2 RECEPTACLES CONTROLLED)

FLUSH IN ACCESS RAISED FLOOR.

#- DENOTES CONNECTED (NOT CONTROLLED) CIRCUIT NUMBER

#C- DENOTES CONNECTED CONTROLLED CIRCUIT VIA PLUG LOAD CONTROLLER

K KIRK KEY SWITCH. MECHANICAL INTERLOCK

SPD SURGE PROTECTION DEVICE

ETSHW ETHERNET SWITCH

#C

"C" -CONTROLLED RECEPTACLE

"TV" -TV/FLAT SCREEN RECEPTACLE

US Army Corps of Engineers ®

G

2 3 4 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

VHALL

J U

N E

W H

N B

-- 1 -3

-0

READY TO ADVERTISE (RTA)

V

IN

C E

N T

H A

L L R

E N

O V

A T

IO

N

P H

A S

E

C:\rvt\2019\10053876-M-VHALL-Central_Johnny.EstradaRL62D.rvt

7/7/2021 7:06:13 AM

E-001-P1

E L E

C T

R

IC

A L S

Y M

B O

L S

A N

D A

B B

R E

V

IA

T

IO

N S

F O

R T

G O

R D

O N

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E N

U E

S A

V A

N N

A H

G

A

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

C C

A N

E T

T I

D A

D A

M

T M

A H

E R

L B

A Y

L O

N

C A

T E

G O

R Y

C O

D E

F Y

P

N

ABBREVIATIONS

A, AMP AMPERES

AF AMP FUSE OR AMP FRAME

AIC. AMPERE INTERRUPTING CAPACITY

AM. AMMETER

AS AMP SWITCH OR AMMETER SWITCH

ASYM. ASYMMETRICAL

AT AMP TRIP

ATS AUTOMATIC TRANSFER SWITCH

AWG AMERICAN WIRE GAUGE

B.O.F. BOTTOM OF FIXTURE

B.C.C. BARE STRANDED COPPER CONDUCTOR

C CONDUIT

CAP. CAPACITY OR CAPACITOR

CATV COMMUNITY ANTENNA TELEVISION

CB CIRCUIT BREAKER

CCTV CLOSED CIRCUIT TELEVISION

CKT, CCT CIRCUIT

C.L. CURRENT LIMITING

C.O. CONDUIT ONLY

CLL CONTRACT LIMIT LINE

CONN. CONNECT OR CONNECTION

DA DURESS ALARM

DB DOOR BELL

DISC. DISCONNECT

DPST DOUBLE POLE SINGLE THROW

EC ELECTRICAL CONTRACTOR

EHD ELECTRICAL HAND DRYER

EWC ELECTRIC WATER COOLER

ELEC ELECTRIC OR ELECTRICAL

ELEV ELEVATION OR ELEVATOR

EMERG, EM EMERGENCY

EPO EMERGENCY POWER OFF

EMT ELECTRICAL METAL TUBING

EG ENGINE GENERATOR

FDR. FEEDER

FIXT. FIXTURE

FLA FULL LOAD AMPERESR

FLUOR. FLUORESCENT

GRC, GCR GALVANIZED RIGID CONDUIT

GEC GROUNDING ELECTRODE CONDUCTOR

GEN GENERATOR

GFCI GROUND FAULT CIRCUIT INTERRUPTER

GFI, GF GROUND FAULT INTERRUPTER

GRD, GND, G GROUND

HID HIGH INTENSITY DISCHARGE

HOA HAND-OFF-AUTO

HP HORSEPOWER

HPS HIGH PRESSURE SODIUM

HZ. HERTZ

IMC. INTERMEDIATE METAL CONDUIT

I.G. ISOLATED GROUND

INCAND. INCANDESCENT

JB JUNCTION BOX

KAIC THOUSAND AMPERE INTERRUPTING CAPACITY

KVA KILOVOLT AMPERES

KW KILOWATT

KWH KILOWATT HOUR

LOD LIMIT OF DISTURBANCE

LTG LIGHTING

LV LOW VOLTAGE

MATV MASTER ANTENNA TELEVISION

MCA MINIMUM CIRCUIT AMPS

MCB MAIN CIRCUIT BREAKER

MCC MOTOR CONTROL CENTER

MH MANHOLE, METAL HALIDE OR MOUNTING HEIGHT

MLO MAIN LUG ONLY

N.C. NORMALL Y CLOSED

NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION

N.E.C NATIONAL ELECTRICAL CODE

N.I.C. NOT IN CONTRACT

NF NON FUSIBLE

NL NIGHT LIGHT

N.O. NORMALLY OPEN

NTS NOT TO SCALE

OCP OVER CURRENT PROTECTION

OL OVERLOADS

P POLE

PB PULL BOX

PH PHASE

PNL PANEL

P.O.C. POINT OF CONNECTION

PR PAIR

PVC POLYVINYL CHLORIDE

PWR. POWER

REC RECEPTACLE

RGS RIGID GALVANIZED STEEL

RTU REMOTE TERMINAL UNIT

RX REQUEST TO EXIT

SOL SOLENOID

SPD SURGE PROTECTION DEVICE

SPDT SINGLE POLE DOUBLE THROW

SPST SINGLE POLE SINGLE THROW

SW. SWITCH

SWBD SWITCHBOARD

SYM SYMMETRICAL

TEL TELEPHONE

TRANSF. TRANSFORMER

TTB TELEPHONE TERMINAL BACKBOARD

TV TELEVISION

TYP TYPICAL

UG UNDERGROUND

U.O.N. UNLESS OTHERWISE NOTED

UPS UNINTERRUPTIBLE POWER SUPPLY

V VOLT

VA VOLT AMPERES

VD VOLTAGE DROP

VM VOLT METER

VS VOLT METER SWITCH

W WATTS OR WIRE

W/ WITH

W/O WITHOUT

WP WEATHERPROOF

XFORM TRANSFORMER

XP EXPLOSION PROOF

EGB ELECTRICAL GROUND BUS

EMGB ELECTRICAL MAIN GROUND BUS

GENERAL NOTES

1. ALL WORK SHALL CONFORM TO FEDERAL, STATE AND LOCAL LAWS, CODES AND

ORDINANCE.

2. PROVIDE ELECTRICAL DEVICES, EQUIPMENT AND INSTALLATION CONFORMING TO

SPECIFICATION.

3. PROVIDE A LIGHTNING PROTECTION SYSTEM IN ACCORDANCE WITH THE DESIGN

PARAMETERS SET FORTH IN NFPA 780, UL96A AND LPI-175. THE LIGHTNING PROTECTION

CONTRACTOR SHALL BE A UL CERTIFIED INSTALLER.

4. THE ELECTRICAL DRAWINGS ARE DIAGRAMMATIC ONLY. REFER TO THE

ARCHITECTURAL DRAWINGS FOR EXACT BUILDING DIMENSIONS.

5. CONDUIT ROUTINGS SHOWN ON THESE PLANS ARE DIAGRAMMATIC. THE CONTRACTOR

SHALL ROUTE FEEDER/BRANCH WIRING AND CONDUIT ALONG THE SHORTEST AND

MOST COST EFFECTIVE ROUTE.

6. THE CONTRACTOR IS REQUIRED TO FURNISH ALL LABOR, MATERIAL AND EQUIPMENT

TO COMPLETE THE PROJECT AS SPECIFIED AND SHOWN ON THE DRAWINGS. WORK

SHALL BE PREPARED BY SKILLED WORKERS IN THEIR RESPECTIVE TRADES,

FOLLOWING MANUFACTURER'S RECOMMENDATIONS. ALL MATERIAL AND EQUIPMENT

PROVIDED SHALL BE NEW.

7. THE CONTRACTOR SHALL FIELD VERIFY THE MOUNTING OF EQUIPMENT AND

COORDINATE WITH OTHER TRADES TO ENSURE PROPER INSTALLATION AND

CLEARANCES.

8. PROVIDE INSULATED BUSHINGS ON ALL STUBBED UP CONDUITS. PROVIDE A PULL

STRING IN ALL EMPTY CONDUITS.

9. LIGHTING IN MECHANICAL ROOMS, TELECOM ROOMS, UTILITY ROOMS AND ELECTRICAL

ROOMS SHALL BE RELOCATED AT NO ADDITIONAL COST TO THE OWNER TO AVOID

CONFLICTS WITH OTHER TRADES. LIGHT FIXTURES SHALL NOT BE PERMITTED TO BE

INSTALLED DIRECTLY ABOVE OTHER TRADES WORK.

10. WORK REQUIRING SHUT DOWN OF EXISTING SYSTEMS SHALL BE COORDINATED AND

PLANNED WITH CONTRACTING OFFICER PRIOR TO THE START OF CONSTRUCTION.

11. ALL COMPONENTS SHOWN ON THE RISER AND SINGLE-LINE DIAGRAMS, BUT NOT ON THE

PLAN OR VICE VERSA, SHALL BE INCLUDED AS IF SHOWN ON BOTH.

12. REFER TO MECHANICAL AND PLUMBING DRAWINGS FOR ALL MECHANICAL AND

PLUMBING EQUIPMENT ABBREVIATIONS AND EXACT LOCATIONS.

13. COORDINATE EXACT LOCATIONS AND MOUNTING HEIGHTS FOR INTERIOR AND EXTERIOR

LIGHT FIXTURES WITH ARCHITECTURAL ELEVATIONS AND DRAWINGS.

14. CONSTRUCTION FOR SECURE AREAS, AND SECURE AREA MATERIAL AND COMPONENTS SHALL

COMPLY WITH UFC 4-010-05 AND IC TECH SPECS FOR ICD/ICS 705 AND FULLY MEET AND PASS

ALL ACCREDITATION.

SCHEDULES

N PH 1 NE(L)(T)1

AREA OF BUILDING

NE - NE ELECTRICAL ROOM

NW - NORTHWEST ELECTRICAL ROOM

SE - SOUTHEAST ELECTRICAL ROOM

SW - SOUTHWEST ELECTRICAL ROOM

M - MAIN ELECTRICAL ROOM

ME - MECHANICAL ROOM EAST

MW - MECHANICAL ROOM WEST

MC - MECHANICAL ROOM CENTER

DISTRIBUTION SYSTEM

N - NORMAL POWER SYSTEM

L - LIFE SAFETY SYSTEM

Q - EQUIPMENT POWER SYSTEM

0.0"

18"

6'-0"

4'-0"

4'-6"

FINISHED FLOOR

10'-0"

WARNING AND SIGNALING FIXTURES/SIGNS

6'-8"

WALL MOUNTED LIGHTING SWITCHES, MANUAL MOTOR STARTERS,

FIRE ALARM PULL STATIONS, WALL MOUNTED TELEPHONES.

TOP OF FLUSH AND SURFACE MOUNTED LIGHTING PANELBOARDS

AND TELEPHONE CABINETS.

TOP OF HIGHEST DISCONNECT SWITCHES, MAGNETIC STARTERS,

CONTACTORS, ATS.

WALL MOUNTED INTERCOM

ELECTRICAL RECEPTACLES, VOICE/DATA OUTLETS, DATA

OUTLETS, UON

BOTTOM LENS FOR WALL MOUNTED FIRE ALARM STROBES

SPEAKERS, HORNS AND COMBINATION HORN/STROBES

BATTERY LIGHTING UNITS AND REMOTE WALL MOUNTED LIGHT

HEADS (OR 1'-0" BELOW FINISHED CEILING AT TOP OF UNIT)

CENTERED

ABOVE

DOOR OR

WINDOW

OPENING

1. MOUNTING HEIGHTS TO CENTER OF OUTLETS UNLESS OTHERWISE NOTED. IN MASONRY

CONSTRUCTION THE ABOVE MOUNTING HEIGHTS SHALL BE USED FOR REFERENCE TO

NEAREST BLOCK OR BRICK COURSING. REFER TO PROJECT SPECIFICATIONS FOR

ADDITIONAL REQUIREMENTS.

7'-0" CLOCK RECEPTACLES

5'-6" GENERATOR REMOTE ANNUNCIATOR

24" GARAGE RECEPTACLES

MOUNTING HEIGHT NOTES

MOUNTING HEIGHT NOTES

SEQUENCE NUMBER

1, 2, 3

L- (LEARNING ENVIROMENT ONLY)

T- (TELECOM ROOM ONLY)

ST SAFETY TYPE

LSIG LONG TIME, SHORT TIME INSTANTANEOUS GROUND

DS CIRCUIT BREAKER TYPE

LEVEL

1 - LEVEL 1

2 - LEVEL 2

UY - UTILITY YARD

PANEL TYPE

US - UNIT SUBSTATION

SG - SWITCHGEAR

VFD - VARIABLE FREQUENCY DRIVE

TR - TRANSFORMER

DH - DISTRIBUTION SWITCHBOARD 480Y/277V, 3P, 4W

DL - DISTRIBUTION SWITCHBOARD 208Y/120V, 3P, 4W

PH - PANEL BOARD 480Y/277V, 3P, 4W

PL - PANELBOARD 208Y/120V, 3P, 4W

VR - LIGHTING INVERTER

DS - DISCONNECT SWITCH

EQUIPMENT IDENTIFICATION

I.T. INFORMATION TECHNOLOGY

US Army Corps of Engineers ®

G

2 3 4 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

VHALL

J U

N E

W H

N B

-- 1 -3

-0

READY TO ADVERTISE (RTA)

V

IN

C E

N T

H A

L L R

E N

O V

A T

IO

N

P H

A S

E

C:\r…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .