USACE_M3_v1.3_20140919.xlsx
XLSX spreadsheet 1 MB Posted
- Solicitation number
- W912EF20R0001
About this file
This document outlines a federal construction contract solicitation for upgrades to the McNary Dam hydroelectric power plant. Key work includes replacing digital governors and exciters on all 14 main generator units, upgrading control systems, replacing piping and other governor mechanical components, and performing related electrical and network infrastructure work. The upgrades must be completed within a 730-day window to coordinate with planned power generation outages. The contract value is estimated between $25-100 million. A site visit will be offered approximately two weeks after solicitation posting. Foreign nationals requesting site visit clearance must provide identity documentation four weeks in advance. The response due date and award date will be in the solicitation. This acquisition is subject to World Trade Organization and Free Trade Agreement terms.
View the file
Other files
Show all 47
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1. Instructions
| Minimum Modeling Matrix (M3) |
| Version: 1.3 (SEPT-19-2014) |
| TABLE OF CONTENTS |
| ❶ TAB 1. Instructions |
| 1. General Instructions |
| 2. Definitions |
| 2.1. Level Of Development Definitions (Accuracy) |
| 2.2. Element Grade Definitions (Format) |
| 3. Frequently Asked Questions |
| 4. Product-Specific M3 Guidance |
| 4.1. Autodesk Revit M3 Guidance |
| 4.2. Bentley AECOSim Building Designer M3 Guidance |
| 5. References |
| 6. M3 Change History |
❷ TAB 2. Modeling Requirements
❸ TAB 3. Scope-LOD-Grade
1. GENERAL INSTRUCTIONS
| 1. Modify Column F on Tab "3. Scope-LOD-Grade" to indicate the Elements included in the Project scope. |
| 2. Filters are available to sort and limit column data in the table. |
| 3. Discipline and Notes columns available as a convenience and are not a contractual requirement. |
| 4. Bi-directional hyperlinks are available in column headers, Element IDs and Modeling Requirements. |
| 2. DEFINITIONS | ||
| 2.1. LEVEL OF DEVELOPMENT DEFINITIONS (ACCURACY) | ||
| The following LOD descriptions identify the specific element requirements for each Model Element. | ||
| LOD | Definition | |
| ● | Refer to the specific child element for appropriate LOD. (Used for categories that have multiple sub-elements for which varying LOD apply.) | |
| 100 | Model Elements indicative of area, height, volume, location, and orientation may be modeled geometrically or represented by other data (i.e., a pump would be a cube.) | |
| 200 | Model Elements are modeled as generalized systems or assemblies with approximate quantities, size, shape, location, and orientation. Non-geometric information may also be attached to Model Elements (i.e., a pump would be a generic pump of approximate size.) | |
| 300 | Model Elements are modeled as specific assemblies accurate in terms of quantity, size, shape, location, and orientation. Non-geometric information may also be attached to Model Elements. Accurate to the degree dimensioned or indicated on contract documents (i.e., a pump would be a generic pump of accurate size complete with connections and clearances for a complete system.) |
| 2.2. ELEMENT GRADE DEFINITIONS (FORMAT) | |
| Within each Level of Development, there is the potential to represent information in various formats. In practice, it has been proven that there are certain elements for which there is a greater benefit in providing 3-dimensional representation, while in others drafting or representation in the form of narratives is sufficient for a particular deliverable. | |
| Grade | Description |
| A | 3D + Facility Data |
| B | 2D + Facility Data |
| C | 2D Only (Drafting, linework, text, and or part of an assembly) |
| + | Original Grade (A, B, or C) adjusted for contract changes and field conditions. |
| - | Not included in or tied to the model (however is still required in the deliverable) |
| ● | Refer to the specific child element for appropriate Grade. (Used for categories that have multiple sub-elements for which varying Grades apply.) |
3. Frequently Asked Questions
| 1. | Question: | This seems like a lot of work. Why does the Corps need this? |
| Answer: | The previous narrative method of Section 4 left too much up to interpretation. Submittals were not consistent. M3 does not require more modeling work than what was required previously and will help ensure clarity in what is asked for and consistency in what is received. It is also intended to help speed up the review process and also to lay the foundation for future requirements such as COBie, analysis, quantification and more. |
| 2. | Question: | Does Column F in Tab 3 allow me to choose what I want to model or not? |
| Answer: | No. Column F shall reflect items which are in the Facility or Site which are in scope for the Project. If the scope changes, update the PxP/M3 and resubmit for approval. |
| 3. | Question: | Why are most of the columns in the spreadsheet locked and the values not editable? |
| Answer: | M3 users are to edit Tab 3, Column F and optionally the Discipline and Notes columns. The values populated in the locked columns are the minimum contractual requirements and as such are not optional so long as the particular Element ID category (i.e. Column Foundations) is within the scope of the project. |
| 4. | Question: | Why can’t I add rows for custom Element IDs? |
| Answer: | The rows reflect standard classification systems. Maintaining these standard categories are necessary for consistent project delivery and review. |
| 5. | Question: | I have an existing project which doesn't use M3. If we get approval and document it in the PxP can we use it? |
| Answer: | Yes. Please make sure to coordinate with the USACE Project Manager, USACE Geographic BIM Manager and resubmit the updated PxP/M3 for formal approval. |
| 6. | Question: | Who do I contact with questions? |
| Answer: | For Project-specific issues, please contact your USACE Project Manager and USACE Geographic BIM Manager. For general questions about the contract language, PxP, or M3, please contact Steve Hutsell (Steve.Hutsell@usace.army.mil) or Van Woods (Van.Woods@usace.army.mil). |
| 7. | Question: | How do I submit a waiver? |
| Answer: | Contact the USACE Project Manager and USACE Geographic BIM Manager. |
| 8. | Question: | I have a question about how a specific object should be classified (for example, where does interior signage go)? |
| Answer: | For OmniClass questions, see: http://omniclass.org/. For UniFormat questions, see: http://www.csinet.org/uniformat. For MasterFormat: http://www.MasterFormat.com. |
| 9. | Question: | The content I have received and downloaded from various sources do not have the correct classification system values assigned (such as Templates, Workspaces, Manufacturer provided content, content from prior projects). Am I responsible for correcting it? |
| Answer: | Yes. |
| 10. | Question: | I work for USACE, should I have to use the PxP and M3 for in-house designed projects? |
| Answer: | Yes. |
| 4. Product-Specific M3 Guidance |
| The following platform specific instructions are provided to demonstrate the application of M3 |
requirements on two platforms, not as an endorsement of these or any specific vendors or platforms.
M3 is specifically designed to be vendor and platform neutral and can be implemented by any platform that can store and report classification system values for each object. The following guidance is provided as-is, without support or guarantees. Use at your own risk.
| 4.1. Autodesk Revit M3 Guidance | |
| If utilizing the UniFormat classification system, the requirement is to populate the Revit system parameter "Assembly Code" and ensure that it matches the UniFormat version in M3. | |
| 1. | Download the M3 Resource Files from the USACE CAD/BIM Center website: |
| A. Revit "container" file for QA/QC for UniFormat validation with Schedules and Filters. | |
| B. Assembly Code text file (updated to UniFormat 2010). | |
| https://cadbim.usace.army.mil/default.aspx?p=a&t=1&i=14 |
| 2. | Update UniformatClassifications.txt on each machine requiring the updated classification system in Revit. |
| A. NOTE: If you plan on using the Autodesk delivered classification system on other projects, make sure to create a backup of the original file. | |
| B. Place the downloaded UniformatClassifications.txt at the following path: | |
| %AppData%\Autodesk\Revit\Autodesk Revit Architecture 2012\ |
C. NOTE: The UniformatClassifications.txt file supplied for the Revit Assembly Code utilizes Uniformat 2010 to match M3 and replaces the original file that comes native to Revit which is based on Uniformat 2004. The updated format results in multiple benign journal file errors that do not effect the operation of Revit.
| 3. | Revit QA/QC resources are available in M3-ComplianceContainerFile.rvt. |
| A. To insert QA/QC Schedules: Insert Tab > Insert From File > Insert Views from File and select all schedules to insert. |
| 4. | Transfer Project Standards > Filters from the M3-ComplianceContainer.rvt |
| A. In the same session of Revit as your project file, open M3-ComplianceContainer.rvt. | |
| B. Navigate to Manage > Transfer Project Standards > Select the proper file, Check NONE, and only select Filters. |
| 5. | As the project is constructed, verify that the appropriate UniFormat values are assigned to all content using: |
| A. Schedules to assign and report on Assembly Code |
B. Filters of Views to help communicate and visualize both for compliance views as well as working views throughout the project's progress.
4.2. Bentley AECOSim Building Designer M3 Guidance
| 1. | Download the following from USACE CAD/BIM Center site: |
| i. The Tri-Service Workspace TS_WS_001 | |
| https://cadbim.usace.army.mil/default.aspx?p=a&t=1&i=11 | |
| ii. M3 Resource Files | |
| https://cadbim.usace.army.mil/default.aspx?p=a&t=1&i=14 |
| 1a. | Ensure the Classifications files are in the following folder |
| TS_Workspaces\TS_WS_001\Workspace\Datasets\Building_US\data\classifications |
2. Check to ensure that Classification is being placed on items. A way to check this is to place a component such as a Wall or a Door, and look for Classification.
| 3. | Through the Item Browser, create a Query that will Search for items without a particular Classification, such as UniFormat. |
| For example: through the Item Browser, select the Search function. |
3a. Set the query to search for Items by Common Properties, where the Classification | UniFormat property is NOT LIKE “?”. Add to Search, and Select OK.
3b. This search will return all components in the model without the UniFormat property filled out. Select the links in the lower portion of the Item Browser to see all the items found.
3c. Right click on a column heading to turn off non-needed columns.
3d. Use the Transparent, the Highlight or the Isolate function in the Item Browser to help communicate and identify what items do not have a Classification assigned.
| 3e. | Use the Transparent function to make the model transparent, and highlight the non-compliant items. |
| 3f. | Use the Highlight function to keep the model in the current display mode, and highlight the non-compliant items. |
| 3g. | Use the Isolate function to filter the model to only show and highlight the non-compliant items. |
4. NOTE: the query can be Saved and re-used in the Item Set toolset.
5. NOTE: The zip file downloaded in Step 1.ii include ECQueries for isolating elements with UniFormat, OmniClass, or Masterformat. The files are named Uniformat.ecquery.xml, OmniClass.ecquery.xml, MasterFormat.ecquery.xml, and All_Classification_Location.ecquery.xml
5. References
| OmniClass |
| Copyright © 2012 OCCS Development Committee Secretariat |
| Table 21 Pre-Consensus Approved Draft 2011-02-11 |
| http://omniclass.org/ |
| UniFormat 2010 |
| UniFormat™ is produced jointly by the Construction Specifications Institute (CSI) and Construction Specifications Canada (CSC). U.S. copyright is held by CSI and Canadian copyright by CSC. All Rights Reserved. For more information on UniFormat, visit www.csinet.org/uniformat. |
| MasterFormat 2010 |
| MasterFormat™ is produced jointly by the Construction Specifications Institute (CSI) and Construction Specifications Canada (CSC). U.S. copyright is held by CSI and Canadian copyright by CSC. All Rights Reserved. For more information on MasterFormat, visit www.MasterFormat.com. |
6. M3 Change History
| Version: 1.3 (SEPT-19-2014) |
| 1. Corrected formatting issues and incorrect hyperlinks. No functional content changes. |
| Version: 1.2 (OCT-03-2013) |
| 1. Change in method for documentation of contributors and credits, no functional content changes. |
| Version: 1.1 (AUG-01-2013) |
| 1. Added BIM application specific M3 implementation guidance and associated resources. |
| 2. Added hyperlinked Table of Contents. |
| 3. Revised LOD 100 wording to remove "three dimensions" as 2D vs 3D is designated by Grade. |
| 4. Fixed typo in FAQ section, added additional FAQ item, fixed typos on tab 2. |
| 5. Fixed names in credits. |
| Version: 1.0 (SEPT-13-2012) |
| 1. Initial Version. |
&D &T Page &P of &N Tab &A
/xl/drawings/drawing1.xml#'3.%20Scope-LOD-Grade'!F4/xl/drawings/drawing1.xml#'3.%20Scope-LOD-Grade'!F4http://omniclass.org/http://www.masterformat.com/http://www.csinet.org/uniformathttp://www.omniclass.org/http://www.omniclass.org/https://cadbim.usace.army.mil/default.aspx?p=a&t=1&i=11https://cadbim.usace.army.mil/default.aspx?p=a&t=1&i=14https://cadbim.usace.army.mil/default.aspx?p=a&t=1&i=14
2. Modeling Requirements
| Minimum Modeling Matrix (M3) |
| Version: 1.3 (SEPT-19-2014) |
Level 01/02 Modeling Requirements
| Level | Class | Element Description |
| Level 1 | A | SUBSTRUCTURE: |
All Substructure elements, with necessary intelligence to produce plans, sections, elevations and schedules; including a depiction of expansion/construction joints.
Level 2 A40 SLABS-ON-GRADE:
Slabs-On-Grade shall be depicted with all necessary recesses, curbs, pads, slopes, closure pours, and major penetrations depicted. Slabs shall be developed in the Structural Model and then referenced by the Architectural Model.
Level 1 B SHELL:
All Shell elements, with necessary intelligence to produce plans, sections elevations, and schedules; including a depiction of expansion/construction joints.
Level 2 B10 SUPERSTRUCTURE:
All columns, primary and secondary framing members, and bracing for the roof and floor systems (including decks), including all necessary intelligence to produce structural framing plans, related building/wall sections, and schedules. Floor Decks and Slabs for Superstructure shall be developed in the Structural Model and then referenced by the Architectural Model.
Level 2 B20 EXTERIOR VERTICAL ENCLOSURES:
Exterior Vertical Enclosures shall be depicted to the exact height, length, width and ratings (thermal, acoustic, fire) to properly reflect element types. Exterior Windows, Doors and Grilles, Louvers and Vents, Hardware Sets using BHMA designations and Wall Appurtenances shall be depicted to represent their actual size, type and location with the necessary intelligence to produce schedules.
Level 1 C INTERIORS:
The Interiors Model may vary in level of detail for individual elements. All Interior elements shall be depicted exact height, length, width and ratings (thermal, acoustic, fire) to properly reflect element types, with necessary intelligence to produce plans, sections and elevations; including a depiction of expansion/construction joints.
Level 2 C10 INTERIOR WINDOWS, DOORS, LOUVERS AND VENTS, INTERIOR SPECIALTIES:
Interior Finishes shall be included in the Facility Data of the host element with the necessary intelligence to produce schedules where applicable. Interior Windows, Doors and Grilles, Louvers and Vents, Hardware Sets using BHMA designations and Wall Appurtenances shall be depicted to represent their actual size, type and location with the necessary intelligence to produce schedules.
Level 2 C20 INTERIOR FINISHES:
Interior Finishes shall be included in the Facility Data of the host element with the necessary intelligence to produce schedules.
Level 1 D SERVICES:
All necessary Services elements including all major openings and penetrations, cable trays, cable bundles and pipe grouping (1-1/2” Ø and larger) shall be depicted with necessary intelligence to produce plans, sections, elevations and schedules where applicable. All clearances and insulation shall be accounted for in the model for use in interference management and maintenance access requirements. Nonpermanent items are not required to be modeled or contain facility data.
Level 2 D20 PLUMBING:
All Plumbing Elements including plumbing piping and fixture layouts, floor and area drains, and related equipment, including necessary intelligence to produce riser diagrams, and schedules where applicable. Small diameter (less than 1-1/2” NPS) field-routed piping is not required to be depicted in the Model. All gravity and insulated piping shall be modeled.
Level 2 D30 HEATING, VENTILATION, AND AIR CONDITIONING (HVAC):
All Heating, Ventilation, and Air Conditioning (HVAC) elements including piping, fixture layouts and related equipment with necessary intelligence to produce riser diagrams, and schedules where applicable. Small diameter (less than 1-1/2” NPS) field-routed piping is not required to be depicted in the Model. All gravity and insulated piping shall be modeled.
Level 2 D40 FIRE PROTECTION:
All Fire Protection elements including all piping, valves, and seismic bracing shall be modeled with necessary intelligence to produce plans, elevations, building/wall sections, riser diagrams, and schedules where applicable.
Level 2 D50 ELECTRICAL:
All Electrical elements including conduit, fixture layouts and related equipment (including power for systems furniture) with necessary intelligence to produce schedules where applicable. Small diameter (less than 1-1/2” Ø) field-routed conduit is not required to be depicted in the Model.
Level 2 D60 COMMUNICATIONS:
All existing and new Communications elements, both above ground and underground, with necessary intelligence to produce schedules where applicable. Small diameter (less than 1-1/2” Ø) field-routed conduit is not required to be depicted in the Model.
Level 2 D70 ELECTRONIC SAFETY AND SECURITY:
All Electronic Safety and Security elements with necessary intelligence to produce schedules. Small diameter (less than 1-1/2” Ø) field-routed conduit is not required to be depicted in the Model.
Level 2 D80 INTEGRATED AUTOMATION:
All Integrated Automation elements with necessary intelligence to produce schedules. Small diameter (less than 1-1/2” Ø) field-routed conduit is not required to be depicted in the Model.
Level 1 E EQUIPMENT AND FURNISHINGS:
All Equipment and Furnishings elements shall be depicted with necessary intelligence to produce plans, sections, elevations and schedules, indicating the configuration, materials, finishes, mechanical, and electrical requirements. Representation of Movable Equipment and Furnishing elements shall be 2D with Facility Data. Contractor shall provide a minimal number of 3D representations as examples. Examples of Movable Equipment and Furnishings include, but are not limited to, desks, desktop printer, desktop computer, furniture systems, seating, tables, and office storage.
Level 2 E10 EQUIPMENT:
Equipment that make use of electrical, data or other features shall include the necessary intelligence to produce coordinated documents, data, and schedules where applicable.
Level 2 E20 FURNISHINGS:
Fixed Furnishings that make use of electrical, data or other features shall include the necessary intelligence to produce coordinated documents, data, and schedules where applicable.
Level 1 F SPECIAL CONSTRUCTION AND DEMOLITION:
All Special Construction and Demolition elements shall be depicted with necessary intelligence to produce plans, sections and elevations.
Level 1 G SITEWORK:
All Sitework (DTM) elements shall be depicted with necessary intelligence to produce Project site, topographical plans, cross sections and profiles. All clearances shall be accounted for in the model for use in interference management and maintenance access requirements.
Level 2 G30 LIQUID AND GAS SITE UTILITIES:
All Liquid and Gas Site Utilities elements with necessary intelligence to produce schedules where applicable. Small diameter (less than 1-1/2” Ø) field-routed piping and conduit is not required to be depicted in the Model.
Level 2 G40 ELECTRICAL SITE IMPROVEMENTS:
All Electrical Site Improvements including all lighting fixtures, relevant existing and proposed support utility lines and equipment with necessary intelligence to produce details and schedules where applicable.
&D &T Page &P of &N Tab &A
3. Scope-LOD-Grade
| Minimum Modeling Matrix (M3) | |||
| Version: 1.3 (SEPT-19-2014) | DESIGN MODEL | ||
| (CONSTRUCTION DOCUMENTS) | RECORD MODEL | ||
| (AS-BUILTS) | FOR AGENCY OR CONTRACTOR INTERNAL USE. |
NOT A CONTRACTUAL REQUIREMENT.
| Level | Element ID | OmniClass | |
| ID | UniFormat | ||
| ID | MasterFormat ID | Included in Facility or Site? | |
| (change to NO if NOT part of project scope) | LOD | GRADE | |
| (CD) | LOD |
(AB)
GRADE
| (AB) | Primary Discipline | ||||||||||
| (This will allow the team to identify discipline-specific areas of content) | Notes | ||||||||||
| Level 1 | SUBSTRUCTURE | 21-01 00 00 | A | Yes | ● | ● | ● | ● | Structural | ||
| Level 2 | FOUNDATIONS | 21-01 10 | A10 | Yes | ● | ● | ● | ● | Structural | ||
| Level 3 | Standard Foundations | 21-01 10 | A1010 | Yes | ● | ● | ● | ● | Structural | ||
| Level 4 | Wall Foundations | 21-01 10 10 | A1010.10 | Yes | 300 | A | 300 | A+ | Structural | ||
| Level 4 | Column Foundations | 21-01 10 10 10 | A1010.30 | Yes | 300 | A | 300 | A+ | Structural | ||
| Level 4 | Standard Foundation Supplementary Components | 21-01 10 10 30 | A1010.90 | Yes | 200 | C | 200 | C+ | Structural | ||
| Level 3 | Special Foundations | 21-01 10 20 | A1020 | 31 60 00 | Yes | ● | ● | ● | ● | Structural | |
| Level 4 | Driven Piles | 21-01 10 20 10 | A1020.10 | 31 62 00 | Yes | 300 | A | 300 | A+ | Structural | |
| Level 4 | Bored Piles | 21-01 10 20 15 | A1020.15 | 31 63 00 | Yes | 300 | A | 300 | A+ | Structural | |
| Level 4 | Caissons | 21-01 10 20 20 | A1020.20 | 31 64 00 | Yes | 300 | A | 300 | A+ | Structural | |
| Level 4 | Special Foundation Walls | 21-01 10 20 30 | A1020.30 | 31 66 16 | Yes | 300 | A | 300 | A+ | Structural | |
| Level 4 | Foundation Anchors | 21-01 10 20 40 | A1020.40 | 31 68 00 | Yes | 100 | C | 100 | C+ | Structural | |
| Level 4 | Underpinning | 21-01 10 20 50 | A1020.50 | 31 48 00 | Yes | 100 | C | 100 | C+ | Structural | |
| Level 4 | Raft Foundations | 21-01 10 20 60 | A1020.60 | 03 71 00 | Yes | 300 | A | 300 | A+ | Structural | |
| Level 4 | Pile Caps | 21-01 10 20 70 | A1020.70 | Yes | 300 | A | 300 | A+ | Structural | ||
| Level 4 | Grade Beams | 21-01 10 20 80 | A1020.80 | Yes | 300 | A | 300 | A+ | Structural | ||
| Level 2 | SUBGRADE ENCLOSURES | 21-01 20 | A20 | Yes | ● | ● | ● | ● | Architectural, Structural | ||
| Level 3 | Walls for Subgrade Enclosures | 21-01 20 10 | A2010 | Yes | ● | ● | ● | ● | Architectural, Structural | ||
| Level 4 | Subgrade Enclosure Wall Construction | 21-01 20 10 10 | A2010.10 | Yes | 300 | A | 300 | A+ | Architectural, Structural | ||
| Level 4 | Subgrade Enclosure Wall Interior Skin | 21-01 20 10 20 | A2010.20 | Yes | 300 | A | 300 | A+ | Architectural | ||
| Level 4 | Subgrade Enclosure Wall Supplementary Components | 21-01 20 10 90 | A2010.90 | Yes | 200 | C | 200 | C+ | Architectural, Structural | ||
| Level 2 | SLABS ON GRADE | 21-01 40 | A40 | Yes | ● | ● | ● | ● | Structural | ||
| Level 3 | Standard Slabs-on-Grade | 21-01 40 10 | A4010 | Yes | 300 | A | 300 | A+ | Structural | ||
| Level 3 | Structural Slabs-on-Grade | 21-01 40 20 | A4020 | Yes | 300 | A | 300 | A+ | Structural | ||
| Level 3 | Slab Trenches | 21-01 40 30 | A4030 | Yes | 300 | A | 300 | A+ | Architectural, Structural | ||
| Level 3 | Pits and Bases | 21-01 40 40 | A4040 | Yes | 300 | A | 300 | A+ | Architectural, Electrical, Equipment, Fire Protection, Mechanical (HVAC), Plumbing, Structural | ||
| Level 3 | Slab-On-Grade Supplementary Components | 21-01 40 90 | A4090 | Yes | ● | ● | ● | ● | Structural | ||
| Level 4 | Perimeter Insulation | 21-01 40 90 10 | A4090.10 | 07 21 00 | Yes | 300 | A | 300 | A+ | Architectural | |
| Level 4 | Vapor Retarder | 21-01 40 90 20 | A4090.20 | 07 26 00 | Yes | 100 | C | 100 | C+ | Architectural | |
| Level 4 | Waterproofing | 21-01 40 90 30 | A4090.30 | 07 10 00 | Yes | 100 | C | 100 | C+ | Architectural | |
| Level 4 | Mud Slab | 21-01 40 90 50 | A4090.50 | 03 30 00 | Yes | 300 | A | 300 | A+ | Structural | |
| Level 4 | Subbase Layer | 21-01 40 90 60 | A4090.60 | 31 23 23 | Yes | 300 | A | 300 | A+ | Structural | |
| Level 2 | WATER AND GAS MITIGATION | 21-01 60 | A60 | Yes | ● | ● | ● | ● | Plumbing, Specialty Consultants | ||
| Level 3 | Building Subdrainage | 21-01 60 10 | A6010 | 33 46 00 | Yes | ● | ● | ● | ● | Plumbing | |
| Level 4 | Foundation Drainage | 21-01 60 10 10 | A6010.10 | 33 46 13 | Yes | 200 | B | 200 | B+ | Plumbing | |
| Level 4 | Underslab Drainage | 21-01 60 10 20 | A6010.20 | 33 46 19 | Yes | 300 | A | 300 | A+ | Plumbing | |
| Level 3 | Off-Gassing Mitigation | 21-01 60 20 | A6020 | 31 21 00 | Yes | ● | ● | ● | ● | Plumbing | |
| Level 4 | Radon Mitigation | 21-01 60 20 10 | A6020.10 | 31 21 13 | Yes | 100 | C | 100 | C+ | Plumbing | |
| Level 4 | Methane Mitigation | 21-01 60 20 50 | A6020.50 | 31 21 16 | Yes | 100 | C | 100 | C+ | Plumbing | |
| Level 2 | SUBSTRUCTURE RELATED ACTIVITIES | 21-01 90 | A90 | Yes | ● | ● | ● | ● | Structural | ||
| Level 3 | Substructure Excavation | 21-01 90 10 | A9010 | 31 23 16 | Yes | ● | ● | ● | ● | Civil, Structural | |
| Level 4 | Backfill and Compaction | 21-01 90 10 10 | A9010.10 | 31 23 23 | Yes | 200 | C | 200 | C+ | Structural | |
| Level 3 | Construction Dewatering | 21-01 90 20 | A9020 | 31 23 19 | Yes | 200 | C | 200 | C+ | Civil, Specialty Consultants | |
| Level 3 | Excavation Support | 21-01 90 30 | A9030 | 31 50 00 | Yes | ● | ● | ● | ● | Specialty Consultants | |
| Level 4 | Anchor Tiebacks | 21-01 90 30 10 | A9030.10 | 31 51 00 | Yes | 100 | C | 100 | C+ | Specialty Consultants | |
| Level 4 | Cofferdams | 21-01 90 30 20 | A9030.20 | 31 52 00 | Yes | 100 | C | 100 | C+ | Architectural, Specialty Consultants | |
| Level 4 | Cribbing and Walers | 21-01 90 30 40 | A9030.40 | 31 53 00 | Yes | 100 | C | 100 | C+ | Specialty Consultants | |
| Level 4 | Ground Freezing | 21-01 90 30 60 | A9030.60 | 31 54 00 | Yes | 100 | C | 100 | C+ | Specialty Consultants | |
| Level 4 | Slurry Walls | 21-01 90 30 70 | A9030.70 | 31 56 00 | Yes | 100 | C | 100 | C+ | Specialty Consultants | |
| Level 3 | Soil Treatment | 21-01 90 40 | A9040 | 31 31 00 | Yes | 100 | C | 100 | C+ | Specialty Consultants | |
| Level 1 | SHELL | 21-02 00 00 | B | Yes | ● | ● | ● | ● | Architectural, Structural | ||
| Level 2 | SUPERSTRUCTURE | 21-02 10 | B10 | Yes | ● | ● | ● | ● | Architectural, Structural | ||
| Level 3 | Floor Construction | 21-02 10 10 | B1010 | Yes | ● | ● | ● | ● | Architectural, Structural | ||
| Level 4 | Floor Structural Frame | 21-02 10 10 10 | B1010.10 | Yes | 300 | A | 300 | A+ | Structural | ||
| Level 4 | Floor decks, slabs and topping | 21-02 10 10 20 | B1010.20 | Yes | 300 | A | 300 | A+ | Structural | ||
| Level 4 | Balcony Floor Construction | 21-02 10 10 30 | B1010.30 | Yes | 300 | A | 300 | A+ | Structural | ||
| Level 4 | Mezzanine Floor Construction | 21-02 10 10 40 | B1010.40 | Yes | 300 | A | 300 | A+ | Structural | ||
| Level 4 | Ramps | 21-02 10 10 50 | B1010.50 | Yes | 300 | A | 300 | A+ | Structural | ||
| Level 4 | Floor Construction Supplementary Components | 21-02 10 10 90 | B1010.90 | Yes | 200 | C | 200 | C+ | Architectural, Structural | ||
| Level 3 | Roof Construction | 21-02 10 20 | B1020 | Yes | ● | ● | ● | ● | Architectural, Structural | ||
| Level 4 | Roof Structural Frame | 21-02 10 20 10 | B1020.10 | Yes | 300 | A | 300 | A+ | Structural | ||
| Level 4 | Roof decks, slabs and sheathing | 21-02 10 20 20 | B1020.20 | Yes | 300 | A | 300 | A+ | Architectural, Structural | ||
| Level 4 | Canopy Construction | 21-02 10 20 30 | B1020.30 | Yes | 300 | A | 300 | A+ | Architectural, Structural | ||
| Level 4 | Roof Construction Supplementary Components | 21-02 10 20 90 | B1020.90 | Yes | 200 | C | 200 | C+ | Architectural, Structural | ||
| Level 3 | Stairs | 21-02 10 80 | B1080 | Yes | ● | ● | ● | ● | Architectural | ||
| Level 4 | Stair Construction | 21-02 10 80 10 | B1080.10 | Yes | 300 | A | 300 | A+ | Architectural, Structural | ||
| Level 4 | Stair Soffits | 21-02 10 80 30 | B1080.30 | Yes | 300 | A | 300 | A+ | Architectural | ||
| Level 4 | Stair Railings | 21-02 10 80 50 | B1080.50 | Yes | 300 | A | 300 | A+ | Architectural | ||
| Level 4 | Fire Escapes | 21-02 10 80 60 | B1080.60 | 05 51 23 | Yes | 300 | A | 300 | A+ | Architectural | |
| Level 4 | Metal Walkways | 21-02 10 80 70 | B1080.70 | 05 51 36 | Yes | 300 | A | 300 | A+ | Architectural | |
| Level 4 | Ladders | 21-02 10 80 80 | B1080.80 | 05 51 23 | Yes | 300 | A | 300 | A+ | Architectural | |
| Level 2 | EXTERIOR VERTICAL ENCLOSURES | 21-02 20 | B20 | Yes | ● | ● | ● | ● | Architectural | ||
| Level 3 | Exterior Walls | 21-02 20 10 | B2010 | Yes | ● | ● | ● | ● | Architectural, Structural | ||
| Level 4 | Exterior Wall Veneer | 21-02 20 10 10 | B2010.10 | Yes | 300 | A | 300 | A+ | Architectural | ||
| Level 4 | Exterior Wall Construction | 21-02 20 10 20 | B2010.20 | Yes | 300 | A | 300 | A+ | Architectural | ||
| Level 4 | Exterior Wall Interior Skin | 21-02 20 10 30 | B2010.30 | Yes | 300 | A | 300 | A+ | Architectural | ||
| Level 4 | Fabricated Exterior Wall Assemblies | 21-02 20 10 40 | B2010.40 | Yes | 300 | A | 300 | A+ | Architectural | ||
| Level 4 | Parapets | 21-02 20 10 50 | B2010.50 | Yes | 300 | A | 300 | A+ | Architectural | ||
| Level 4 | Equipment Screens | 21-02 20 10 60 | B2010.60 | Yes | 300 | A | 300 | A+ | Architectural | ||
| Level 4 | Exterior Wall Supplementary Components | 21-02 20 10 80 | B2010.80 | Yes | 300 | C | 300 | C+ | Architectural, Structural | ||
| Level 4 | Exterior Wall Opening Supplementary Components | 21-02 20 10 90 | B2010.90 | Yes | 100 | C | 100 | C+ | Architectural | ||
| Level 3 | Exterior Windows | 21-02 20 20 | B2020 | 08 50 00 | Yes | ● | ● | ● | ● | Architectural | |
| Level 4 | Exterior Operating Windows | 21-02 20 20 10 | B2020.10 | 08 50 00 | Yes | 300 | A | 300 | A+ | Architectural | |
| Level 4 | Exterior Fixed Windows | 21-02 20 20 20 | B2020.20 | 08 50 00 | Yes | 300 | A | 300 | A+ | Architectural | |
| Level 4 | Exterior Window Wall | 21-02 20 20 30 | B2020.30 | Yes | 300 | A | 300 | A+ | Architectural | ||
| Level 4 | Exterior Special Function Windows | 21-02 20 20 50 | B2020.50 | 08 56 00 | Yes | 300 | A | 300 | A+ | Architectural | |
| Level 3 | Exterior Doors and Grilles | 21-02 20 50 | B2050 | Yes | ● | ● | ● | ● | Architectural | ||
| Level 4 | Exterior Entrance Doors | 21-02 20 50 10 | B2050.10 | 08 42 00 | Yes | 300 | A | 300 | A+ | Architectural | |
| Level 4 | Exterior Utility Doors | 21-02 20 50 20 | B2050.20 | 08 10 00 | Yes | 300 | A | 300 | A+ | Architectural | |
| Level 4 | Exterior Oversize Doors | 21-02 20 50 30 | B2050.30 | Yes | 300 | A | 300 | A+ | Architectural | ||
| Level 4 | Exterior Special Function Doors | 21-02 20 50 40 | B2050.40 | 08 30 00 | Yes | 300 | A | 300 | A+ | Architectural | |
| Level 4 | Exterior Grilles | 21-02 20 50 60 | B2050.60 | Yes | 300 | A | 300 | A+ | Architectural | ||
| Level 4 | Exterior Gates | 21-02 20 50 70 | B2050.70 | Yes | 300 | A | 300 | A+ | Architectural | ||
| Level 4 | Exterior Door Supplementary Components | 21-02 20 50 90 | B2050.90 | Yes | 300 | C | 300 | C+ | Architectural | ||
| Level 3 | Exterior Louvers and Vents | 21-02 20 70 | B2070 | 08 90 00 | Yes | ● | ● | ● | ● | Architectural | |
| Level 4 | Exterior Louvers | 21-02 20 70 10 | B2070.10 | 08 91 00 | Yes | 300 | A | 300 | A+ | Architectural | |
| Level 4 | Exterior Vents | 21-02 20 70 50 | B2070.50 | 08 95 00 | Yes | 300 | A | 300 | A+ | Architectural | |
| Level 3 | Exterior Wall Appurtenances | 21-02 20 80 | B2080 | Yes | ● | ● | ● | ● | Architectural | ||
| Level 4 | Exterior Fixed Grilles and Screens | 21-02 20 80 10 | B2080.10 | 10 82 13 | Yes | 300 | A | 300 | A+ | Architectural | |
| Level 4 | Exterior Opening Protection Devices | 21-02 20 80 30 | B2080.30 | Yes | 300 | C | 300 | C+ | Architectural | ||
| Level 4 | Exterior Balcony Walls and Railings | 21-02 20 80 50 | B2080.50 | 05 52 00 | Yes | 300 | A | 300 | A+ | Architectural | |
| Level 4 | Exterior Fabrications | 21-02 20 80 70 | B2080.70 | Yes | 300 | A | 300 | A+ | Architectural | ||
| Level 4 | Bird Control Devices | 21-02 20 80 80 | B2080.80 | 10 81 13 | Yes | 100 | C | 100 | C+ | Architectural | |
| Level 3 | Exterior Wall Specialties | 21-02 20 90 | B2090 | 10 74 00 | Yes | 300 | B | 300 | B+ | Architectural | |
| Level 2 | EXTERIOR HORIZONTAL ENCLOSURES | 21-02 30 | B30 | Yes | ● | ● | ● | ● | Architectural | ||
| Level 3 | Roofing | 21-02 30 10 | B3010 | Yes | ● | ● | ● | ● | Architectural | ||
| Level 4 | Steep Slope Roofing | 21-02 30 10 10 | B3010.10 | 07 30 00 | Yes | 300 | A | 300 | A+ | Architectural | |
| Level 4 | Low-Slope Roofing | 21-02 30 10 50 | B3010.50 | Yes | 300 | A | 300 | A+ | Architectural | ||
| Level 4 | Canopy Roofing | 21-02 30 10 70 | B3010.70 | Yes | 300 | A | 300 | A+ | Architectural | ||
| Level 4 | Roofing Supplementary Components | 21-02 30 10 90 | B3010.90 | Yes | 200 | C | 200 | C+ | Architectural | ||
| Level 3 | Roof Appurtenances | 21-02 30 20 | B3020 | Yes | ● | ● | ● | ● | Architectural | ||
| Level 4 | Roof Accessories | 21-02 30 20 10 | B3020.10 | 07 72 00 | Yes | 200 | A | 200 | A+ | Architectural | |
| Level 4 | Roof Specialties | 21-02 30 20 30 | B3020.30 | 10 74 00 | Yes | 200 | B | 200 | B+ | Architectural | |
| Level 4 | Rainwater Management | 21-02 30 20 70 | B3020.70 | ND | Yes | 200 | A | 200 | A+ | Architectural | |
| Level 3 | Traffic Bearing Horizontal Enclosures | 21-02 30 40 | B3040 | Yes | ● | ● | ● | ● | Architectural | ||
| Level 4 | Traffic Bearing Coatings | 21-02 30 40 10 | B3040.10 | 07 18 00 | Yes | 100 | C | 100 | C+ | Architectural | |
| Level 4 | Horizontal Waterproofing Membrane | 21-02 30 40 30 | B3040.30 | 07 10 00 | Yes | 200 | C | 200 | C+ | Architectural | |
| Level 4 | Wear Surfaces | 21-02 30 40 50 | B3040.50 | Yes | 300 | C | 300 | C+ | Architectural | ||
| Level 4 | Horizontal Enclosure Supplementary Components | 21-02 30 40 90 | B3040.90 | Yes | 300 | C | 300 | C+ | Architectural | ||
| Level 3 | Horizontal Openings | 21-02 30 60 | B3060 | Yes | ● | ● | ● | ● | Architectural | ||
| Level 4 | Roof Windows and Skylights | 21-02 30 60 10 | B3060.10 | 08 60 00 | Yes | 300 | A | 300 | A+ | Architectural | |
| Level 4 | Vents and Hatches | 21-02 30 60 50 | B3060.50 | Yes | 300 | A | 300 | A+ | Architectural | ||
| Level 4 | Horizontal Opening Supplementary Components | 21-02 30 60 90 | B3060.90 | Yes | 300 | C | 300 | C+ | Architectural | ||
| Level 3 | Overhead Exterior Enclosures | 21-02 30 80 | B3080 | Yes | ● | ● | ● | ● | Architectural | ||
| Level 4 | Exterior Ceilings | 21-02 30 80 10 | B3080.10 | Yes | 300 | A | 300 | A+ | Architectural | ||
| Level 4 | Exterior Soffits | 21-02 30 80 20 | B3080.20 | Yes | 300 | A | 300 | A+ | Architectural | ||
| Level 4 | Exterior Bulkheads | 21-02 30 80 30 | B3080.30 | Yes | 300 | A | 300 | A+ | Architectural | ||
| Level 1 | INTERIORS | 21-03 00 00 | C | Yes | ● | ● | ● | ● | Architectural, Equipment, Interiors, Mechanical (HVAC), Plumbing | ||
| Level 2 | INTERIOR CONSTRUCTION | 21-03 10 | C10 | Yes | ● | ● | ● | ● | Architectural | ||
| Level 3 | Interior Partitions | 21-03 10 10 | C1010 | 10 22 00 | Yes | ● | ● | ● | ● | Architectural | |
| Level 4 | Interior Fixed Partitions | 21-03 10 10 10 | C1010.10 | Yes | 300 | A | 300 | A+ | Architectural | ||
| Level 4 | Interior Glazed Partitions | 21-03 10 10 20 | C1010.20 | Yes | 300 | A | 300 | A+ | Architectural | ||
| Level 4 | Interior Demountable Partitions | 21-03 10 10 40 | C1010.40 | 10 22 19 | Yes | 300 | B | 300 | B+ | Architectural | |
| Level 4 | Interior Operable Partitions | 21-03 10 10 50 | C1010.50 | Yes | 300 | A | 300 | A+ | Architectural | ||
| Level 4 | Interior Screens | 21-03 10 10 70 | C1010.70 | Yes | 300 | B | 300 | B+ | Architectural | ||
| Level 4 | Interior Partition Supplementary Components | 21-03 10 10 90 | C1010.90 | Yes | 200 | C | 200 | C+ | Architectural | ||
| Level 3 | Interior Windows (a.k.a borrowed lites) | 21-03 10 20 | C1020 | 08 50 00 | Yes | ● | ● | ● | ● | Architectural | |
| Level 4 | Interior Operating Windows | 21-03 10 20 10 | C1020.10 | 08 50 00 | Yes | 300 | A | 300 | A+ | Architectural | |
| Level 4 | Interior Fixed Windows | 21-03 10 20 20 | C1020.20 | 08 50 00 | Yes | 300 | A | 300 | A+ | Architectural | |
| Level 4 | Interior Special Function Windows | 21-03 10 20 50 | C1020.50 | 08 50 00 | Yes | 300 | A | 300 | A+ | Architectural | |
| Level 4 | Interior Window Supplementary Components | 21-03 10 20 90 | C1020.90 | 08 50 00 | Yes | 300 | C | 300 | C+ | Architectural | |
| Level 3 | Interior Doors | 21-03 10 30 | C1030 | 08 10 00 | Yes | ● | ● | ● | ● | Architectural | |
| Level 4 | Interior Swinging Doors | 21-03 10 30 10 | C1030.10 | 08 10 00 | Yes | 300 | A | 300 | A+ | Architectural | |
| Level 4 | Interior Entrance Doors | 21-03 10 30 20 | C1030.20 | 08 10 00 | Yes | 300 | A | 300 | A+ | Architectural | |
| Level 4 | Interior Sliding Doors | 21-03 10 30 25 | C1030.25 | 08 42 00 | Yes | 300 | A | 300 | A+ | Architectural | |
| Level 4 | Interior Folding Doors | 21-03 10 30 30 | C1030.30 | 08 11 73 | Yes | 300 | A | 300 | A+ | Architectural | |
| Level 4 | Interior Coiling Doors | 21-03 10 30 40 | C1030.40 | 08 35 13 | Yes | 300 | A | 300 | A+ | Architectural | |
| Level 4 | Interior Panel Doors | 21-03 10 30 50 | C1030.50 | 08 33 00 | Yes | 300 | A | 300 | A+ | Architectural | |
| Level 4 | Interior Special Function Doors | 21-03 10 30 70 | C1030.70 | 08 36 00 | Yes | 300 | A | 300 | A+ | Architectural | |
| Level 4 | Interior Access Doors and Panels | 21-03 10 30 80 | C1030.80 | 08 30 00 | Yes | 300 | A | 300 | A+ | Architectural | |
| Level 4 | Interior Door Supplementary Components | 21-03 10 30 90 | C1030.90 | 08 31 00 | Yes | 200 | C | 200 | C+ | Architectural | |
| Level 3 | Interior Grilles and Gates | 21-03 10 40 | C1040 | Yes | ● | ● | ● | ● | Architectural | ||
| Level 4 | Interior Grilles | 21-03 10 40 10 | C1040.10 | Yes | 300 | A | 300 | A+ | Architectural | ||
| Level 4 | Interior Gates | 21-03 10 40 50 | C1040.50 | Yes | 300 | A | 300 | A+ | Architectural | ||
| Level 3 | Raised Floor Construction | 21-03 10 60 | C1060 | Yes | ● | ● | ● | ● | Architectural, Electrical | ||
| Level 4 | Access Flooring | 21-03 10 60 10 | C1060.10 | 09 69 00 | Yes | 200 | A | 200 | A+ | Architectural, Electrical | |
| Level 4 | Platform/Stage Floors | 21-03 10 60 30 | C1060.30 | Yes | 200 | A | 200 | A+ | Architectural, Electrical | ||
| Level 3 | Suspended Ceiling Construction | 21-03 10 70 | C1070 | Yes | ● | ● | ● | ● | Architectural | ||
| Level 4 | Acoustical Suspended Ceilings | 21-03 10 70 10 | C1070.10 | 09 51 00 | Yes | 200 | A | 200 | A+ | Architectural | |
| Level 4 | Suspended Plaster and Gypsum Board Ceilings | 21-03 10 70 20 | C1070.20 | Yes | 300 | A | 300 | A+ | Architectural | ||
| Level 4 | Specialty Suspended Ceilings | 21-03 10 70 50 | C1070.50 | 09 54 00 | Yes | 200 | A | 200 | A+ | Architectural | |
| Level 4 | Special Function Suspended Ceilings | 21-03 10 70 70 | C1070.70 | 09 57 00 | Yes | 200 | A | 200 | A+ | Architectural | |
| Level 4 | Ceiling Suspension Components | 21-03 10 70 90 | C1070.90 | Yes | 100 | C | 100 | C+ | Architectural | ||
| Level 3 | Interior Specialties | 21-03 10 90 | C1090 | Yes | ● | ● | ● | ● | Architectural, Equipment, Mechanical (HVAC), Plumbing | ||
| Level 4 | Interior Railings and Handrails | 21-03 10 90 10 | C1090.10 | Yes | 300 | A | 300 | A+ | Architectural | ||
| Level 4 | Interior Louvers | 21-03 10 90 15 | C1090.15 | 08 91 00 | Yes | 300 | A | 300 | A+ | Architectural, Mechanical (HVAC) | |
| Level 4 | Information Specialties | 21-03 10 90 20 | C1090.20 | 10 10 00 | Yes | 200 | B | 200 | B+ | Architectural, Electrical | |
| Level 4 | Compartments and Cubicles | 21-03 10 90 25 | C1090.25 | 10 21 00 | Yes | 200 | C | 200 | C+ | Architectural, Interiors | |
| Level 4 | Service Walls | 21-03 10 90 30 | C1090.30 | 10 25 00 | Yes | 300 | A | 300 | A+ | Architectural, Electrical, Plumbing | |
| Level 4 | Wall and Door Protection | 21-03 10 90 35 | C1090.35 | 10 26 00 | Yes | 200 | C | 200 | C+ | Architectural | |
| Level 4 | Toilet, Bath, and Laundry Accessories | 21-03 10 90 40 | C1090.40 | 10 28 00 | Yes | 200 | A | 200 | A+ | Architectural | |
| Level 4 | Interior Gas Lighting | 21-03 10 90 45 | C1090.45 | 10 84 16 | Yes | 300 | A | 300 | A+ | Electrical, Interiors | |
| Level 4 | Fireplaces and stoves | 21-03 10 90 50 | C1090.50 | 10 30 00 | Yes | 300 | A | 300 | A+ | Architectural | |
| Level 4 | Safety Specialties | 21-03 10 90 60 | C1090.60 | 10 40 00 | Yes | 200 | A | 200 | A+ | Architectural, Interiors | |
| Level 4 | Storage Specialties | 21-03 10 90 70 | C1090.70 | 10 50 00 | Yes | 200 | A | 200 | A+ | Architectural | |
| Level 4 | Other Interior Specialties | 21-03 10 90 90 | C1090.90 | 10 80 00 | Yes | 200 | C | 200 | C+ | Architectural | |
| Level 2 | INTERIOR FINISHES | 21-03 20 | C20 | Yes | ● | ● | ● | ● | Interiors | ||
| Level 3 | Wall Finishes | 21-03 20 10 | C2010 | 09 70 00 | Yes | ● | ● | ● | ● | Interiors | |
| Level 4 | Tile Wall Finish | 21-03 20 10 10 | C2010.10 | 09 30 00 | Yes | 200 | B | 200 | B+ | Interiors | |
| Level 4 | Wall Paneling | 21-03 20 10 20 | C2010.20 | Yes | 200 | B | 200 | B+ | Interiors | ||
| Level 4 | Wall Coverings | 21-03 20 10 30 | C2010.30 | 09 72 00 | Yes | 200 | B | 200 | B+ | Interiors | |
| Level 4 | Wall Carpeting | 21-03 20 10 35 | C2010.35 | 09 73 00 | Yes | 200 | B | 200 | B+ | Interiors | |
| Level 4 | Stone Facing | 21-03 20 10 50 | C2010.50 | 09 75 00 | Yes | 200 | B | 200 | B+ | Interiors | |
| Level 4 | Special Wall Surfacing | 21-03 20 10 60 | C2010.60 | 09 77 00 | Yes | 200 | B | 200 | B+ | Interiors | |
| Level 4 | Wall Painting and Coating | 21-03 20 10 70 | C2010.70 | 09 90 00 | Yes | 200 | B | 200 | B+ | Interiors | |
| Level 4 | Acoustical Wall Treatment | 21-03 20 10 80 | C2010.80 | Yes | 100 | B | 100 | B+ | Interiors | ||
| Level 4 | Wall Finish Supplementary Components | 21-03 20 10 90 | C2010.90 | Yes | 200 | C | 200 | C+ | Interiors | ||
| Level 3 | Interior Fabrications | 21-03 20 20 | C2020 | Yes | 100 | B | 100 | B+ | Interiors | ||
| Level 3 | Flooring | 21-03 20 30 | C2030 | 09 60 00 | Yes | ● | ● | ● | ● | Architectural, Interiors | |
| Level 4 | Flooring Treatment | 21-03 20 30 10 | C2030.10 | 09 61 00 | Yes | 200 | B | 200 | B+ | Interiors | |
| Level 4 | Tile Flooring | 21-03 20 30 20 | C2030.20 | 09 30 00 | Yes | 200 | B | 200 | B+ | Interiors | |
| Level 4 | Specialty Flooring | 21-03 20 30 30 | C2030.30 | 09 62 00 | Yes | 200 | B | 200 | B+ | Interiors | |
| Level 4 | Masonry Flooring | 21-03 20 30 40 | C2030.40 | 09 63 00 | Yes | 200 | B | 200 | B+ | Interiors | |
| Level 4 | Wood Flooring | 21-03 20 30 45 | C2030.45 | 09 64 00 | Yes | 200 | B | 200 | B+ | Interiors | |
| Level 4 | Resilient Flooring | 21-03 20 30 50 | C2030.50 | 09 65 00 | Yes | 200 | B | 200 | B+ | Interiors | |
| Level 4 | Terrazzo Flooring | 21-03 20 30 60 | C2030.60 | 09 66 00 | Yes | 200 | B | 200 | B+ | Interiors | |
| Level 4 | Fluid-Applied Flooring | 21-03 20 30 70 | C2030.70 | 09 67 00 | Yes | 200 | B | 200 | B+ | Interiors | |
| Level 4 | Carpeting | 21-03 20 30 75 | C2030.75 | 09 68 00 | Yes | 200 | B | 200 | B+ | Interiors | |
| Level 4 | Athletic Flooring | 21-03 20 30 80 | C2030.80 | Yes | 200 | B | 200 | B+ | Interiors | ||
| Level 4 | Entrance Flooring | 21-03 20 30 85 | C2030.85 | Yes | 200 | B | 200 | B+ | Interiors | ||
| Level 4 | Flooring Supplementary Components | 21-03 20 30 90 | C2030.90 | Yes | 200 | C | 200 | C+ | Interiors | ||
| Level 3 | Stair Finishes | 21-03 20 40 | C2040 | Yes | ● | ● | ● | ● | Architectural, Interiors | ||
| Level 4 | Tile Stair Finish | 21-03 20 40 20 | C2040.20 | 09 30 00 | Yes | 100 | B | 100 | B+ | Interiors | |
| Level 4 | Masonry Stair Finish | 21-03 20 40 40 | C2040.40 | 09 63 00 | Yes | 100 | B | 100 | B+ | Interiors | |
| Level 4 | Wood Stair Finish | 21-03 20 40 45 | C2040.45 | 09 64 00 | Yes | 100 | B | 100 | B+ | Interiors | |
| Level 4 | Resilient Stair Finish | 21-03 20 40 50 | C2040.50 | 09 65 00 | Yes | 100 | B | 100 | B+ | Interiors | |
| Level 4 | Terrazzo Stair Finish | 21-03 20 40 60 | C2040.60 | 09 66 00 | Yes | 100 | B | 100 | B+ | Interiors | |
| Level 4 | Carpeted Stair Finish | 21-03 20 40 75 | C2040.75 | 09 68 00 | Yes | 100 | B | 100 | B+ | Interiors | |
| Level 3 | Ceiling Finishes | 21-03 20 50 | C2050 | 09 50 00 | Yes | ● | ● | ● | ● | Architectural, Interiors | |
| Level 4 | Plaster and Gypsum Board Finish | 21-03 20 50 10 | C2050.10 | 09 20 00 | Yes | 200 | B | 200 | B+ | Architectural, Interiors | |
| Level 4 | Ceiling Paneling | 21-03 20 50 20 | C2050.20 | Yes | 200 | B | 200 | B+ | Architectural, Interiors | ||
| Level 4 | Ceiling Painting and Coating | 21-03 20 50 70 | C2050.70 | 09 90 00 | Yes | 100 | B | 100 | B+ | Architectural, Interiors | |
| Level 4 | Acoustical Ceiling Treatment | 21-03 20 50 80 | C2050.80 | Yes | 200 | B | 200 | B+ | Architectural, Interiors | ||
| Level 4 | Ceiling Finish Supplementary Components | 21-03 20 50 90 | C2050.90 | Yes | 200 | C | 200 | C+ | Architectural, Interiors | ||
| Level 1 | SERVICES | 21-04 00 00 | D | Yes | ● | ● | ● | ● | Architectural, Electrical, Fire Protection, Mechanical (HVAC), Plumbing | ||
| Level 2 | CONVEYING | 21-04 10 | D10 | 14 00 00 | Yes | ● | ● | ● | ● | Architectural, Specialty Consultants | |
| Level 3 | Vertical Conveying Systems | 21-04 10 10 | D1010 | Yes | ● | ● | ● | ● | Architectural | ||
| Level 4 | Elevators | 21-04 10 10 10 | D1010.10 | 14 20 00 | Yes | 200 | A | 200 | A+ | Architectural | |
| Level 4 | Lifts | 21-04 10 10 20 | D1010.20 | 14 40 00 | Yes | 200 | A | 200 | A+ | Architectural | |
| Level 4 | Escalators | 21-04 10 10 30 | D1010.30 | 14 31 00 | Yes | 200 | A | 200 | A+ | Architectural | |
| Level 4 | Dumbwaiters | 21-04 10 10 50 | D1010.50 | 14 10 00 | Yes | 200 | A | 200 | A+ | Architectural | |
| Level 4 | Moving Ramps | 21-04 10 10 60 | D1010.60 | 14 33 00 | Yes | 200 | A | 200 | A+ | Architectural | |
| Level 3 | Horizontal Conveying Systems | 21-04 10 30 | D1030 | Yes | ● | ● | ● | ● | Architectural | ||
| Level 4 | Moving Walks | 21-04 10 30 10 | D1030.10 | 14 32 00 | Yes | 300 | A | 300 | A+ | Architectural | |
| Level 4 | Turntables | 21-04 10 30 30 | D1030.30 | 14 70 00 | Yes | 300 | A | 300 | A+ | Architectural | |
| Level 4 | Passenger Loading Bridges | 21-04 10 30 50 | D1030.50 | 34 77 13 | Yes | 300 | A | 300 | A+ | Architectural | |
| Level 4 | People Movers | 21-04 10 30 70 | D1030.70 | Yes | 300 | A | 300 | A+ | Architectural | ||
| Level 3 | Material Handling | 21-04 10 50 | D1050 | Yes | ● | ● | ● | ● | Specialty Consultants | ||
| Level 4 | Cranes | 21-04 10 50 10 | D1050.10 | 41 22 13 | Yes | 300 | A | 300 | A+ | Specialty Consultants | |
| Level 4 | Hoists | 21-04 10 50 20 | D1050.20 | 41 22 23 | Yes | 300 | A | 300 | A+ | Specialty Consultants | |
| Level 4 | Derricks | 21-04 10 50 30 | D1050.30 | 41 22 33 | Yes | 300 | A | 300 | A+ | Specialty Consultants | |
| Level 4 | Conveyors | 21-04 10 50 40 | D1050.40 | 41 21 00 | Yes | 300 | A | 300 | A+ | Specialty Consultants | |
| Level 4 | Baggage Handling Equipment | 21-04 10 50 50 | D1050.50 | 34 77 16 | Yes | 300 | A | 300 | A+ | Specialty Consultants | |
| Level 4 | Chutes | 21-04 10 50 60 | D1050.60 | 14 91 00 | Yes | 200 | A | 200 | A+ | Specialty Consultants | |
| Level 4 | Pneumatic Tube Systems | 21-04 10 50 70 | D1050.70 | 14 92 00 | Yes | 300 | A | 300 | A+ | Specialty Consultants | |
| Level 3 | Operable Access Systems | 21-04 10 80 | D1080 | Yes | ● | ● | ● | ● | Specialty Consultants | ||
| Level 4 | Suspended Scaffolding | 21-04 10 80 10 | D1080.10 | 14 81 00 | Yes | 200 | A | 200 | A+ | Specialty Consultants | |
| Level 4 | Rope Climbers | 21-04 10 80 20 | D1080.20 | 14 82 00 | Yes | 200 | B | 200 | B+ | Specialty Consultants | |
| Level 4 | Elevating Platforms | 21-04 10 80 30 | D1080.30 | 14 83 00 | Yes | 200 | A | 200 | A+ | Specialty Consultants | |
| Level 4 | Powered Scaffolding | 21-04 10 80 40 | D1080.40 | 14 84 00 | Yes | 200 | A | 200 | A+ | Specialty Consultants | |
| Level 4 | Building Envelope Access | 21-04 10 80 50 | D1080.50 | Yes | 200 | C | 200 | C+ | Specialty Consultants | ||
| Level 2 | PLUMBING | 21-04 20 | D20 | 22 00 00 | Yes | ● | ● | ● | ● | Plumbing | |
| Level 3 | Domestic Water Distribution | 21-04 20 10 | D2010 | 22 11 00 | Yes | ● | ● | ● | ● | Plumbing | |
| Level 4 | Facility Potable-Water Storage Tanks | 21-04 20 10 10 | D2010.10 | 22 12 00 | Yes | 300 | A | 300 | A+ | Plumbing | |
| Level 4 | Domestic Water Equipment | 21-04 20 10 20 | D2010.20 | Yes | 300 | A | 300 | A+ | Plumbing | ||
| Level 4 | Domestic Water Piping | 21-04 20 10 40 | D2010.40 | 22 11 16 | Yes | 300 | A | 300 | A+ | Plumbing | |
| Level 4 | Plumbing Fixtures | 21-04 20 10 60 | D2010.60 | 22 40 00 | Yes | 300 | A | 300 | A+ | Plumbing | |
| Level 4 | Domestic Water Distribution Supplementary Components | 21-04 20 10 90 | D2010.90 | Yes | 100 | A | 100 | A+ | Plumbing | ||
| Level 3 | Sanitary Drainage | 21-04 20 20 | D2020 | 22 13 00 | Yes | ● | ● | ● | ● | Plumbing | |
| Level 4 | Sanitary Sewerage Equipment | 21-04 20 20 10 | D2020.10 | Yes | 300 | A | 300 | A+ | Plumbing | ||
| Level 4 | Sanitary Sewerage Piping | 21-04 20 20 30 | D2020.30 | Yes | 300 | A | 300 | A+ | Plumbing | ||
| Level 4 | Sanitary Drainage Supplementary Components | 21-04 20 20 90 | D2020.90 | Yes | 100 | A | 100 | A+ | Plumbing | ||
| Level 3 | Building Support Plumbing Systems | 21-04 20 30 | D2030 | 22 14 00 | Yes | ● | ● | ● | ● | Plumbing | |
| Level 4 | Stormwater Drainage Equipment | 21-04 20 30 10 | D2030.10 | Yes | 300 | A | 300 | A+ | Plumbing | ||
| Level 4 | Stormwater Drainage Piping | 21-04 20 30 20 | D2030.20 | 22 14 13 | Yes | 300 | A | 300 | A+ | Plumbing | |
| Level 4 | Facility Stormwater Drains | 21-04 20 30 30 | D2030.30 | 22 14 26 | Yes | 300 | A | 300 | A+ | Plumbing | |
| Level 4 | Gray Water Systems | 21-04 20 30 60 | D2030.60 | Yes | 300 | A | 300 | A+ | Plumbing | ||
| Level 4 | Building Support Plumbing System Supplementary Components | 21-04 20 30 90 | D2030.90 | Yes | 100 | A | 100 | A+ | Plumbing | ||
| Level 3 | General Service Compressed-Air | 21-04 20 50 | D2050 | 22 15 00 | Yes | 300 | A | 300 | A+ | Plumbing | |
| Level 3 | Process Support Plumbing Systems | 21-04 20 60 | D2060 | Yes | ● | ● | ● | ● | Plumbing | ||
| Level 4 | Compressed-Air Systems | 21-04 20 60 10 | D2060.10 | 22 61 00 | Yes | 300 | A | 300 | A+ | Plumbing | |
| Level 4 | Vacuum Systems | 21-04 20 60 20 | D2060.20 | 22 62 00 | Yes | 300 | A | 300 | A+ | Plumbing | |
| Level 4 | Gas Systems | 21-04 20 60 30 | D2060.30 | 22 63 00 | Yes | 300 | A | 300 | A+ | Plumbing | |
| Level 4 | Chemical-Waste Systems | 21-04 20 60 40 | D2060.40 | 22 66 00 | Yes | 300 | A | 300 | A+ | Plumbing | |
| Level 4 | Processed Water Systems | 21-04 20 60 50 | D2060.50 | 22 67 00 | Yes | 300 | A | 300 | A+ | Plumbing | |
| Level 4 | Process Support Plumbing System Supplementary Components | 21-04 20 60 90 | D2060.90 | Yes | 100 | A | 100 | A+ | Plumbing | ||
| Level 2 | HVAC | 21-04 30 | D30 | 23 00 00 | Yes | ● | ● | ● | ● | Mechanical (HVAC) | |
| Level 3 | Facility Fuel Systems | 21-04 30 10 | D3010 | 23 10 00 | Yes | ● | ● | ● | ● | Mechanical (HVAC) | |
| Level 4 | Fuel Piping | 21-04 30 10 10 | D3010.10 | 23 11 00 | Yes | 300 | A | 300 | A+ | Mechanical (HVAC) | |
| Level 4 | Fuel Pumps | 21-04 30 10 30 | D3010.30 | 23 12 00 | Yes | 300 | A | 300 | A+ | Mechanical (HVAC) | |
| Level 4 | Fuel Storage Tanks | 21-04 30 10 50 | D3010.50 | 23 13 00 | Yes | 300 | A | 300 | A+ | Mechanical (HVAC) | |
| Level 3 | Heating Systems | 21-04 30 20 | D3020 | Yes | ● | ● | ● | ● | Mechanical (HVAC) | ||
| Level 4 | Heat Generation | 21-04 30 20 10 | D3020.10 | Yes | 300 | A | 300 | A+ | Mechanical (HVAC) | ||
| Level 4 | Thermal Heat Storage | 21-04 30 20 30 | D3020.30 | 23 71 13 | Yes | 300 | A | 300 | A+ | Mechanical (HVAC) | |
| Level 4 | Decentralized Heating Equipment | 21-04 30 20 70 | D3020.70 | 23 80 00 | Yes | 300 | A | 300 | A+ | Mechanical (HVAC) | |
| Level 4 | Heating System Supplementary Components | 21-04 30 20 90 | D3020.90 | Yes | 100 | A | 100 | A+ | Mechanical (HVAC) | ||
| Level 3 | Cooling Systems | 21-04 30 30 | D3030 | Yes | ● | ● | ● | ● | Mechanical (HVAC) | ||
| Level 4 | Central Cooling | 21-04 30 30 10 | D3030.10 | 23 60 00 | Yes | 300 | A | 300 | A+ | Mechanical (HVAC) | |
| Level 4 | Evaporative Air-Cooling | 21-04 30 30 30 | D3030.30 | 23 76 00 | Yes | 300 | A | 300 | A+ | Mechanical (HVAC) | |
| Level 4 | Thermal Cooling Storage | 21-04 30 30 50 | D3030.50 | 23 71 00 | Yes | 300 | A | 300 | A+ | Mechanical (HVAC) | |
| Level 4 | Decentralized Cooling | 21-04 30 30 70 | D3030.70 | 23 80 00 | Yes | 300 | A | 300 | A+ | Mechanical (HVAC) | |
| Level 4 | Cooling System Supplementary Components | 21-04 30 30 90 | D3030.90 | Yes | 100 | A | 100 | A+ | Mechanical (HVAC) | ||
| Level 3 | Facility HVAC Distribution Systems | 21-04 30 50 | D3050 | Yes | ● | ● | ● | ● | Mechanical (HVAC) | ||
| Level 4 | Facility Hydronic Distribution | 21-04 30 50 10 | D3050.10 | Yes | 300 | A | 300 | A+ | Mechanical (HVAC) | ||
| Level 4 | Facility Steam Distribution | 21-04 30 50 30 | D3050.30 | Yes | 300 | A | 300 | A+ | Mechanical (HVAC) | ||
| Level 4 | HVAC Air Distribution | 21-04 30 50 50 | D3050.50 | Yes | 300 | A | 300 | A+ | Mechanical (HVAC) | ||
| Level 4 | Facility Distribution Systems Supplementary Components | 21-04 30 50 90 | D3050.90 | Yes | 100 | A | 100 | A+ | Mechanical (HVAC) | ||
| Level 3 | Ventilation | 21-04 30 60 | D3060 | Yes | ● | ● | ● | ● | Mechanical (HVAC) | ||
| Level 4 | Supply Air | 21-04 30 60 10 | D3060.10 | Yes | 300 | A | 300 | A+ | Mechanical (HVAC) | ||
| Level 4 | Return Air | 21-04 30 60 20 | D3060.20 | Yes | 300 | A | 300 | A+ | Mechanical (HVAC) | ||
| Level 4 | Exhaust Air | 21-04 30 60 30 | D3060.30 | Yes | 300 | A | 300 | A+ | Mechanical (HVAC) | ||
| Level 4 | Outside Air | 21-04 30 60 40 | D3060.40 | Yes | 300 | A | 300 | A+ | Mechanical (HVAC) | ||
| Level 4 | Air-to-Air Energy Recovery | 21-04 30 60 60 | D3060.60 | 23 72 00 | Yes | 300 | A | 300 | A+ | Mechanical (HVAC) | |
| Level 4 | HVAC Air Cleaning | 21-04 30 60 70 | D3060.70 | 23 40 00 | Yes | 300 | B | 300 | B+ | Mechanical (HVAC) | |
| Level 4 | Ventilation Supplementary Components | 21-04 30 60 90 | D3060.90 | Yes | 100 | A | 100 | A+ | Mechanical (HVAC) | ||
| Level 3 | Special Purpose HVAC Systems | 21-04 30 70 | D3070 | Yes | ● | ● | ● | ● | Mechanical (HVAC) | ||
| Level 4 | Snow Melting | 21-04 30 70 10 | D3070.10 | 23 83 00 | Yes | 300 | B | 300 | B+ | Mechanical (HVAC) | |
| Level 2 | FIRE PROTECTION | 21-04 40 | D40 | 21 00 00 | Yes | ● | ● | ● | ● | Architectural, Fire Protection | |
| Level 3 | Fire Suppression | 21-04 40 10 | D4010 | 10 44 00 | Yes | ● | ● | ● | ● | Fire Protection | |
| Level 4 | Water-Based Fire-Suppression | 21-04 40 10 10 | D4010.10 | 21 10 00 | Yes | 300 | A | 300 | A+ | Fire Protection | |
| Level 4 | Fire-Extinguishing | 21-04 40 10 50 | D4010.50 | 21 20 00 | Yes | 300 | A | 300 | A+ | Fire Protection | |
| Level 4 | Fire Suppression Supplementary Components | 21-04 40 10 90 | D4010.90 | Yes | 100 | A | 100 | A+ | Fire Protection | ||
| Level 3 | Fire Protection Specialties | 21-04 40 30 | D4030 | 26 00 00 | Yes | ● | ● | ● | ● | Architectural | |
| Level 4 | Fire Protection Cabinets | 21-04 40 30 10 | D4030.10 | 10 44 13 | Yes | 200 | A | 200 | A+ | Architectural | |
| Level 4 | Fire Extinguishers | 21-04 40 30 30 | D4030.30 | 10 44 16 | Yes | 200 | A | 200 | A+ | Architectural | |
| Level 4 | Breathing Air Replenishment Systems | 21-04 40 30 50 | D4030.50 | 10 44 33 | Yes | 200 | A | 200 | A+ | Architectural | |
| Level 4 | Fire Extinguisher Accessories | 21-04 40 30 70 | D4030.70 | 10 44 43 | Yes | 200 | A | 200 | A+ | Architectural | |
| Level 2 | ELECTRICAL | 21-04 50 | D50 | Yes | ● | ● | ● | ● | Electrical | ||
| Level 3 | Facility Power Generation | 21-04 50 10 | D5010 | Yes | ● | ● | ● | ● | Electrical | ||
| Level 4 | Packaged Generator Assemblies | 21-04 50 10 10 | D5010.10 | 26 32 00 | Yes | 200 | A | 200 | A+ | Electrical, Specialty Consultants | |
| Level 4 | Battery Equipment | 21-04 50 10 20 | D5010.20 | 26 33 00 | Yes | 200 | A | 200 | A+ | Electrical, Mechanical (HVAC), Specialty Consultants | |
| Level 4 | Photovoltaic Collectors | 21-04 50 10 30 | D5010.30 | 26 31 00 | Yes | 200 | A | 200 | A+ | Architectural, Electrical, Specialty Consultants | |
| Level 4 | Fuel Cells | 21-04 50 10 40 | D5010.40 | 48 18 00 | Yes | 200 | A | 200 | A+ | Electrical, Plumbing, Specialty Consultants | |
| Level 4 | Power Filtering and Conditioning | 21-04 50 10 60 | D5010.60 | 26 35 00 | Yes | 200 | A | 200 | A+ | Electrical | |
| Level 4 | Transfer Switches | 21-04 50 10 70 | D5010.70 | 26 36 00 | Yes | 200 | A | 200 | A+ | Electrical | |
| Level 4 | Facility Power Generation Supplementary Components | 21-04 50 10 90 | D5010.90 | Yes | 100 | A | 100 | A+ | Electrical, Specialty Consultants | ||
| Level 3 | Electrical Service and Distribution | 21-04 50 20 | D5020 | Yes | ● | ● | ● | ● | Electrical | ||
| Level 4 | Electrical Service | 21-04 50 20 10 | D5020.10 | 26 21 00 | Yes | 200 | A | 200 | A+ | Electrical | |
| Level 4 | Power Distribution | 21-04 50 20 30 | D5020.30 | 26 20 00 | Yes | 200 | A | 200 | A+ | Electrical | |
| Level 4 | Facility Grounding | 21-04 50 20 70 | D5020.70 | 26 05 26 | Yes | 200 | A | 200 | A+ | Electrical | |
| Level 4 | Electrical Service and Distribution Supplementary Components | 21-04 50 20 90 | D5020.90 | Yes | 200 | A | 200 | A+ | Electrical | ||
| Level 3 | General Purpose Electrical Power | 21-04 50 30 | D5030 | Yes | ● | ● | ● | ● | Electrical | ||
| Level 4 | Branch Wiring System | 21-04 50 30 10 | D5030.10 | Yes | 200 | B | 200 | B+ | Electrical | ||
| Level 4 | Wiring Devices | 21-04 50 30 50 | D5030.50 | 26 27 26 | Yes | 200 | B | 200 | B+ | Electrical | |
| Level 4 | General Purpose Electrical Power Supplementary Components | 21-04 50 30 90 | D5030.90 | Yes | 200 | B | 200 | B+ | Electrical | ||
| Level 3 | Lighting | 21-04 50 40 | D5040 | 26 50 00 | Yes | ● | ● | ● | ● | Electrical | |
| Level 4 | Lighting Control | 21-04 50 40 10 | D5040.10 | 26 09 23 | Yes | 300 | A | 300 | A+ | Electrical | |
| Level 4 | Branch Wiring for Lighting | 21-04 50 40 20 | D5040.20 | Yes | 300 | B | 300 | B+ | Electrical | ||
| Level 4 | Lighting Fixtures | 21-04 50 40 50 | D5040.50 | 26 50 00 | Yes | 300 | A | 300 | A+ | Electrical | |
| Level 4 | Lighting Supplementary Components | 21-04 50 40 90 | D5040.90 | Yes | 200 | A | 200 | A+ | Electrical | ||
| Level 3 | Miscellaneous Electrical Systems | 21-04 50 80 | D5080 | Yes | ● | ● | ● | ● | Electrical | ||
| Level 4 | Lightning Protection | 21-04 50 80 10 | D5080.10 | 26 41 00 | Yes | 200 | B | 200 | B+ | Electrical | |
| Level 4 | Cathodic Protection | 21-04 50 80 40 | D5080.40 | 26 42 00 | Yes | 200 | A | 200 | A+ | Electrical | |
| Level 4 | Transient Voltage Suppression | 21-04 50 80 70 | D5080.70 | 26 43 00 | Yes | 200 | A | 200 | A+ | Electrical |