Plans_20R0001_McQuad_amd0009_8Oct20.pdf
PDF 12 MB Posted
- Solicitation number
- W912EF20R0001
About this file
This solicitation is for a construction contract to upgrade the governors, exciters, and powerhouse controls at McNary Dam in Umatilla County, Oregon. Key requirements include upgrading digital governors and installing new contractor-furnished excitation systems on all 14 main hydropower generator units. Additional work involves replacing governor air compressors, upgrading the 125VDC distribution panels, and installing a new fiber optic communications network. The contract is valued between $25-100 million and has a performance period ending January 2025. Offerors must be able to support potential multiple daily work shifts and 7-day work weeks to meet schedule constraints requiring upgrades to be completed on pairs of units within 16-20 week windows. The solicitation will be conducted as a best value trade-off and awarded as a fixed price contract. The Department of the Army Corps of Engineers Walla Walla District is the issuing agency.
View the file
Other files
Show all 47
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
D A
T E
A P
P R
®of Engineers
US Army Corps of Engineers
US Army Corps
IS
S
U E D
A T
E
W A
L L
A W
A L L
A
W A
S H
IN
G T
O N
WALLA WALLA DISTRICT
c p w w o r k p w n w p d m s
M D
P
G
V
X X d g n
D E S
IG
N
F
IL
E
D A
T E
A
D
IM
E
P
L O
T T
E D
M
C O
L U
M B
IA
R
IV
E R
M C
N A
R Y L
O C
K A
N D D
A M
W E
F
R
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
W A
L L
A W
A L L
A D
IS
T R
IC
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
P O
R T
L A
N D
O R
E G
O N
IDENTIFICATION
SHEET
VOLUME 1
P O
W E
R H
O U
S E E
X C
IT
E R
S
G O
V E
R N
O R
S P
O W
E R
H O
U S
E C
O N
T R
O L S U
P G
R A
G-013
W
IL
L
IA
IN
E X F
O R I
N F
O R
M A
T
IO
N O
N L
Y D
R A
W
IN
G
P .K
E L L E
R
M D
P -1 .5
-0 /5
K
C H
E N
S T
E V
E N R
M
IL
E S P .E
S H
E E
T
M D
P .5
G -0
V
X X .d g n
FIO-765
FIO-764
471D8085D86
471D8085D86
UPLOADING VALVE ASSEMBLY WITH PUMP CONTROL SWITCH
GOVERNOR OIL PRESSURE SYSTEM PIPING
R
E V
IS
E D P
E R A
M E
N D
M E
N T
TITLE
REFERENCE
FIO FILE NUMBER FIO FILE NUMBER
INDEX TO FIO DRAWINGS INDEX TO FIO DRAWINGS
TITLE
NUMBER
SHEET
FIO
NUMBER
SHEET
FIO
L
O W
P -1
C LC L
P -2
ASSEMBLY
BAY
A-1A-2
UNIT
STATION
SERVICE
BAY
UNIT
P-1P-2P-3P-4P-5P-6P-7P-8P-9P-10P-11P-12P-13P-14P-15
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
FISH
PUMP-
HOUSE
C L P -3
DN
MAIN UNITS
CL
CL
A2 A1
SS-01
BKR
GEN
LOCKER ROOM
RESTROOM AND
CH12
BKR
GEN
EL 287 EL 287
SQ1 BUS 2
EXP GND BUS
EXISTING 4''
SEE NOTE 14
CEILING/FLOOR BLOCKOUT
BLOCK OUT
LOUVERED
SEE NOTES 12, 13
CABLE TRAY
EXISTING OVERHEAD
UNIT 2
UNIT 1
DOOR
COILING
OVERHEAD
DRAIN (TYP.)
CL
HRG
HRG
SQ1C SQ1C
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
D A
T E
A P
P R
®of Engineers
US Army Corps of Engineers
US Army Corps
IS
S
U E D
A T
E
W A
L L
A W
A L L
A
W A
S H
IN
G T
O N
WALLA WALLA DISTRICT
c p w w o r k p w n w p d m s
M D
P
E
V
X X d g n
D E S
E
D A
E
P
L O
T T
E D
C O
L U
M B
IA
R
IV
E R
M C
N A
R Y L
O C
K A
N D D
A M
W E
F
R
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
W A
L L
A W
A L L
A D
IS
T R
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
P O
R T
L A
N D
O R
E G
O N
IDENTIFICATION
SHEET
VOLUME 1
P O
W E
R H
O U
S E E
X C
IT
E R
S
G O
V E
R N
O R
S P
O W
E R
H O
U S
E C
O N
T R
O L S U
P G
R A
D E
ABBREVIATIONS:
EXISTING EQUIPMENT
NEW WORK
GOVERNMENT FURNISHED EQUIPMENT
EXISTING SS FOCN CONDUIT & PULL BOX
8'0 4' 16'
NOTES:
PLAN EL 287.0, BAYS 1 & 2MDP-1.46-6-1E40/1
LEGEND:
WALLA WALLA DISTRICT
S I
P .5
E -1
V
X X .d g n
D
W
IL
L
IA
M S
E L
E-102
W
E R
H O
U S
E L
A Y
O U
T E
Q U
IP
M E
N T P
L A
N
S1
SEE NOTE 10
(SX2)
EXCITER
SEE NOTE 11
NEW BUS DUCT
SEE NOTE 11
NEW EXCITER CABINET
SEE NOTES 6, 9, 17, 18
S1FB1
SEE NOTES 12, 13
CABLE TRAY
NEW OVERHEAD
(SX1)
EXCITER
SEE NOTE 11
NEW BUS DUCT
SEE NOTE 11
NEW EXCITER CABINET
REFERENCE:
PANEL
PATCH
S1FP1
SEE NOTE 16
CONTROL CABINET
DIGITAL GOVERNOR
MAIN UNIT 3
CONTINUES TO
SEE NOTES 1-5, 9, 14, 15
MU FOCN CONDUIT
SCALE: NTS
RTU1
N
N
SEE NOTES 7-9, 15
CORE DRILL
MU DIGITAL EXCITERSX_
STATION SERVICESS
GENERATOR SWITCHBOARDS_
REMOTE TERMINAL UNITRTU
MAIN UNITMU
FIBER OPTIC CONTROL NETWORKFOCN
FIBER OPTICFO
COMMUNICATIONCOMM
ACTUATORA_
P .K
E L L E
R
SEE NOTES 4-6, 9, 14
S1FB2
SEE NOTE 11
RIGGING
NEW BRUSH
SEE NOTE 11
RIGGING
NEW BRUSH
M A
IN
U
N
IT
S I
N S
T A
L L
K
C H
E N
S T
E V
E N R
M
IL
E S P .E
NOTE 20
(CE12.1, CE12.2, CE12.3)
NEW DC PANELS
WIREWAY
NOTE 21
CABINET (BPA1)
NEW BPA RELAYING
SFN/RTU CABINET
RELOCATED TO
NEW RTU
PULL BOX.
FOR EACH CABLE AROUND THE INSIDE PERIMETER OF THE
4. INSTALL A MINIMUM OF ONE LOOP OF FIBER OPTIC CABLE
ROUTED THRU STATION SERVICE PULL BOXES.
CONTRACTING OFFICER, MU FO CONDUIT/CABLES MAY BE
3. WHEN NECESSARY AND WITH APPROVAL OF THE
THE STATION SERVICE CONDUITS.
SYSTEM MAY BE ROUTED ON THE SAME STRUT SYSTEM WITH
SEPARATELY TO THE GREATEST EXTENT POSSIBLE. MU FO
SERVICE FO CONTROL COMM NETWORK SHALL BE ROUTED
2. MAIN UNIT FO CONTROL COMM NETWORK AND STATION
THE BREAKER GALLERY USING A STRUT SYSTEM.
NETWORK IS ROUTED IN RMC MOUNTED TO THE CEILING IN
1. EXISTING, RECENTLY INSTALLED STATION SERVICE FO COMM
R E
V
IS
E D P
E R A
M E
N D
M E
N T
ELECTRIC CODE.
VERIFY CONDUIT FILL REQUIREMENTS PER THE NATIONAL
CONDUIT AND CABLE TRAY. CONTRACTOR TO CALCULATE AND
AND EXISTING EQUIPMENT ARE INTENDED TO USE EXISTING
CABLES FOR ROUTING BETWEEN NEW S-BOARDS, SC-BOARDS
IN GENERAL, EXCEPT AS SHOWN OTHERWISE, CONTROL
23. ADDITIONAL NOTES REGARDING CABLE ROUTING ON E-103.
POINTS.
ENCLOSURES. VERIFY AND REUSE EXISTING GROUNDING
22. EQUIPMENT GROUNDING REQUIRED FOR NEW CABINETS AND
BPA CABINET AND LEAVE SPARE CABLE LENGTH AVAILABLE.
THEIR CABINET. ROUTE CONDUIT AND CONTROL CABLES TO
SAME OUTAGE. BPA WILL MAKE WIRING TERMINATIONS IN
BONNEVILLE POWER ADMINISTRATION (BPA) DURING THE
WILL BE RELOCATED, DESIGNED AND INSTALLED BY THE
21. NEW LINE RELAYING, INCLUDING CABINET AND EQUIPMENT,
CODE.
JUNCTION BOXES AS NECESSARY PER NATIONAL ELECTRIC
RESPONSIBLE FOR ROUTING CONDUIT AND PLACING
INFORMATION AND DETAILS. CONTRACTOR SHALL BE
DISTRIBUTION PANELS DRAWING FOR ADDITIONAL
LOCATION ON UPSTREAM WALL. SEE VOL1 125 VDC POWER
20. 125 VDC POWER DISTRIBUTION PANELS SHOWN IN GENERAL
MINIMUM DIMENSIONS 12" X 12" X 6".
IRREVERSIBLE COVER PLATES, BE RATED NEMA 12, AND HAVE
JUNCTION BOXES FOR FIBER OPTIC CABLE MUST HAVE
SHOWN MUST BE APPROVED BY THE CONTRACTING OFFICER.
NATIONAL ELECTRIC CODE. DEVIATIONS FROM THE LAYOUT
CONDUIT AND PLACING JUNCTION BOXES AS NECESSARY PER
19. CONTRACTOR SHALL BE RESPONSIBLE FOR ROUTING
INFORMATION AND DETAILS.
PANEL DETAIL DRAWING IN VOL 1 FOR ADDITIONAL
SHALL TERMINATE AT A RACK MOUNTED PATCH PANEL. SEE
TECHNICAL SPECIFICATIONS. FIBERS IN MU FOCN PANEL
18. ALL FIBERS SHALL BE TERMINATED AND TESTED PER THE
ADDITIONAL REQUIREMENTS.
DRAWINGS AND BLOCK DIAGRAM. SEE SPECIFICATIONS FOR
GOVERNMENT. SEE VOL 1 RTU PANEL ELEVATION AND LAYOUT
IS SUPPLIED, PROGRAMMED AND COMMISSIONED BY THE
FO PATCH PANELS. GFE FO COMMUNICATION EQUIPMENT
SHELVES, EQUIPMENT RACK SLIDES, AND RACK MOUNTED
CONTRACTOR. RTU0 WILL INCLUDE 19" RACKS, SLIDE OUT
17. RTU CABINETS ARE TO BE PROVIDED AND INSTALLED BY THE
AND REQUIREMENTS.
TECHNICAL SPECIFICATIONS FOR ADDITIONAL INFORMATION
FURNISHED, CONTRACTOR INSTALLED. SEE VOL 2 & 3 AND
16. DIGITAL GOVERNOR CONTROL CABINET IS GOVERNMENT
BLOCK DIAGRAM FOR ADDITIONAL INFORMATION.
MOUNTED PULL BOXES IN THE BREAKER GALLERY. SEE VOL 1
15. MU FOCN CONDUITS AND CABLES ROUTE THROUGH WALL
TO EXISTING.
ON THE WALL AND CEILING WITH A STRUT SYSTEM SIMILAR
OF THE 305 CABLE GALLERY. CONDUIT SHALL BE INSTALLED
TO THE FLOOR/CEILING BLOCK OUT, AND UP TO THE CEILING
ROUTED FROM MAIN UNIT #1 PULL BOX TO THE CEILING, OVER
14. THE MU FOCN CONDUIT AND CABLE HOME RUN SHALL BE
SIMILAR TO EXISTING SUPPORT BRACKETS.
BACK OF THE ALCOVE AND BE SUPPORTED WITH BRACKETS
THE NEW EXCITER. THESE SECTIONS SHALL EXTEND TO THE
13. CABLE TRAY SHALL ALIGN WITH THE TERMINAL SECTIONS OF
OF A MINIMUM 18 INCH WIDTH.
CONNECTIONS WILL BE REPLACED WITH NEW CABLE TRAY
12. THE EXISTING OVERHEAD CABLE TRAY FOR EXCITER
SPECIFICATIONS.
INFORMATION AND REQUIREMENTS SEE TECHNICAL
REPLACED WITH A NEW EXCITER. FOR ADDITIONAL
11. EXISTING EXCITER WILL BE DISCONNECTED, REMOVED AND
MEET SUPPORT REQUIREMENTS.
CONDUIT SUPPORTS AT EACH EDGE OF EACH ALCOVE TO
SUPPORTED PER NEC ARTICLE 344. THIS WILL REQUIRE
10. 2" CONDUIT SPANNING THE ALCOVE OPENINGS SHALL BE
NUTS.
PULL BOX SHALL STAND OFF FROM WALL TO ALLOW FOR LOCK
WITH TWO LOCK NUTS, ONE INSIDE AND ONE OUT. PANEL AND
SECURED TO BOTH THE RTU1 CABINET AND THE PULL BOX
9. CONDUIT SHALL BE THREADED AT BOTH ENDS AND SHALL BE
FIRESTOP AROUND CONDUIT PER TECHNICAL SPECIFICATIONS.
TRANSITION DOWN AND INTO THE TOP OF THE CABINETS.
BOX IN THE CIRCUIT BREAKER GALLERY. MAKE A 90-DEGREE
8. INSTALL A 2" RMC BETWEEN THE RTU1 CABINET AND A PULL
A 2" RMC.
ENTRANCE TO THE RTU1 CABINET. SIZE THE CORE DRILL FOR
CIRCUIT BREAKER GALLERY IN LINE WITH THE PLANNED
OF THE WALL BETWEEN THE GENERATOR FLOOR AND THE
7. CORE DRILL AT A LEVEL ABOVE THE CABINETS ON BOTH SIDES
AND THE TOP OF THE CABINET BACK PANEL.
AT THE TOP OF THE CABINET BETWEEN THE CABINET CEILING
6. CONDUIT FOR FIBER CABLES SHALL ENTER THE RTU1 CABINET
INSULATED THROAT TYPE GROUNDING END BUSHING.
5. ALL CONDUIT ENDS SHALL BE TERMINATED WITH AN
KEY PLAN
PARTIAL PLAN EL 287 BAYS 1 & 2
C .J
C .J
FISH
PUMP-
HOUSE
F L
O W
ASSEMBLY
BAY
A-1A-2
UNIT
STATION
SERVICE
BAY
P-1P-2
UNIT
P-3P-4P-5P-6P-7P-8P-9P-10P-11P-12P-13P-14P-15
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
P -3
C L
BKR
GEN
SJ3.1C
CH22
A4 A3
CLR
DOOR
COILING
OVERHEAD
SS-03
DN
MAIN UNITSCL
CL
EL 287
DN
EL 287
CL
P -5
C L
P -4
C L
PWR J-BOX
SJ3.1 DC
SQ2 BUS 2
BUS 1
SJ3.1
BUS 2
SJ3.1
BKR
GEN
SEE NOTES 12, 13
CABLE TRAY
OVERHEAD
EXISTING
BLOCK OUT
LOUVERED
DRAIN (TYP.)
UNIT 3
UNIT 4
BUS 1
SQ1
PULL BOX
SS FOCN
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
D A
T E
A P
P R
®of Engineers
US Army Corps of Engineers
US Army Corps
IS
S
U E D
A T
E
W A
L L
A W
A L L
A
W A
S H
IN
G T
O N
WALLA WALLA DISTRICT
c p w w o r k p w n w p d m s
M D
P
E
V
X X d g n
D E S
E
D A
E
P
L O
T T
E D
C O
L U
M B
IA
R
IV
E R
M C
N A
R Y L
O C
K A
N D D
A M
W E
F
R
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
W A
L L
A W
A L L
A D
IS
T R
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
P O
R T
L A
N D
O R
E G
O N
IDENTIFICATION
SHEET
VOLUME 1
P O
W E
R H
O U
S E E
X C
IT
E R
S
G O
V E
R N
O R
S P
O W
E R
H O
U S
E C
O N
T R
O L S U
P G
R A
D E
S
P .5
E -1
V
X X .d g n
D
W
IL
L
IA
M S
E L
P O
W E
R H
O U
S E L
A Y
O U
T E
Q U
IP
M E
N T P
L A
E-103
SCALE: NTS
16'8'0'
N
SEE NOTE 11
NEW BUS DUCT
(SX4)
EXCITER
SEE NOTE 11
NEW EXCITER CABINET
SEE NOTES 12, 13
CABLE TRAY
NEW OVERHEAD
(SX3)
EXCITER
SEE NOTE 11
NEW BUS DUCT
SEE NOTE 11
NEW EXCITER CABINET
SEE NOTES 6, 9, 17, 18
SEE NOTE 16
CONTROL CABINET
DIGITAL GOVERNOR
PANEL
PATCH
S2FP1
NOTES:
MAIN UNIT 5
CONTINUES TO
S2
S2FB1
RTU2
SEE NOTES 1-5, 9, 14, 15
MU FOCN CONDUIT
SEE NOTES 1-3
SS FOCN CONDUIT
REFERENCES:
PLAN EL 287, BAYS 3 & 4MDP-1.46-6-1E40/1
SEE NOTES 7-9, 15
CORE DRILL
P .K
E L L E
R
SEE NOTE 10
4-6, 9, 14
SEE NOTES
S2FB2
SEE NOTE 11
RIGGING
NEW BRUSH
SEE NOTE 11
RIGGING
NEW BRUSH
M A
IN
U
N
IT
S I
N S
T A
L L
K
C H
E N
S T
E V
E N R
M
IL
E S P .E
NOTE 20
(CE22.1, CE22.2, CE22.3)
NEW DC PANELS
WIREWAY
SFN/RTU CAB
RELOCATED TO
NEW RTU
CONDUIT CAN BE PROVIDED AS REQUESTED.
FIO DRAWINGS FOR ADDITIONAL EXISTING EMBEDDED
(UNITS 3&4 DETAILS EL 287.0) MDP-2.1-6-1F1/5
(U4 DS HALF EL 287.0) MDP-2.1-6-1F1/4
(U4 DS HALF EL 287.0) MDP-2.1-6-1F1/3
(U3 US HALF EL 287.0) MDP-2.1-6-1F1/2
(U3 DS HALF EL 287.0) MDP-2.1-6-1F1/1
SEE FIO DRAWINGS
(PIER A-1 TO P-3 EL 361.0) MDP-2.1-6-1D/-7
(INTAKE DECK EL 361.0) MDP-2.1-6-1F1/6
(U1/U2 GALLERIES EL 305.0-346.0) MDP-2.1-6-1E1/6
(U1/U2 DETAILS EL 287.0) MDP-2.1-6-1E1/5
(U1/U2 WEST OF CL EL 287.0) MDP-2.1-6-1E1/4
(U1/U2 EAST OF CL EL 287.0) MDP-2.1-6-1E1/3
(U1/U2 EL 287.0) MDP-2.1-6-1E1/2
(U1/U2 EL 267.5) MDP-2.1-6-1E1/1
SEE FIO DRAWINGS
SC-BOARD CONTROLS.
CONDUIT AND CABLE AS NEEDED FOR NEW S-BOARD AND
2. REUSE EXISTING ROUTING AND INSTALL ADDITIONAL
1. ABBREVIATIONS, NOTES AND LEGEND ON DRAWING E-102.
NOTE 21
CABINET (BPA2)
NEW BPA RELAYING
R
E V
IS
E D P
E R A
M E
N D
M E
N T
KEY PLAN
PARTIAL PLAN EL 287 BAYS 3 & 4
C .J
C .J
TOILET
SS-07
P -5
CH32
P -6
DN
CL
MAIN UNITS
A5A6
BKR
GEN
C L
C L
CL
P -7
CL
BKR
GEN
C L
HOUSE
PUMP-
FISH
F L
O W
ASSEMBLY
BAY
A-1A-2
UNIT
STATION
SERVICE
BAY
P-1P-2
UNIT
P-3P-4P-5P-6P-7P-8P-9P-10P-11P-12P-13P-14P-15
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
EL 287 EL 287
UNIT 5
DOOR
COILING
OVERHEAD
SEE NOTE 14
CEILING/FLOOR BLOCKOUT
UNIT 6
SEE NOTES 12, 13
CABLE TRAY
OVERHEAD
EXISTING
BLOCK OUT
LOUVERED
CEO1A.1
PANEL
125V DC
CEO1B.1
PANEL
125V DC
DRAIN (TYP)
480V CABLES TO EL 267
EXISTING 18" TRAYS FOR
ZJJFF
HRG
SQ2C
HRG
BUS 1
SQ2
PULL BOX
SS FOCN CONDUIT
SEE NOTES 1-3
SS FOCN CONDUIT
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
D A
T E
A P
P R
®of Engineers
US Army Corps of Engineers
US Army Corps
IS
S
U E D
A T
E
W A
L L
A W
A L L
A
W A
S H
IN
G T
O N
WALLA WALLA DISTRICT
c p w w o r k p w n w p d m s
M D
P
E
V
X X d g n
D E S
E
D A
E
P
L O
T T
E D
C O
L U
M B
IA
R
IV
E R
M C
N A
R Y L
O C
K A
N D D
A M
W E
F
R
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
W A
L L
A W
A L L
A D
IS
T R
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
P O
R T
L A
N D
O R
E G
O N
IDENTIFICATION
SHEET
VOLUME 1
P O
W E
R H
O U
S E E
X C
IT
E R
S
G O
V E
R N
O R
S P
O W
E R
H O
U S
E C
O N
T R
O L S U
P G
R A
D E
8'0 4' 16'
N
PLAN EL 287.0, BAYS 5 & 6MDP-1.46-6-1E40/1
S
P .5
E -1
V
X X .d g n
D
W
IL
L
IA
M S
E L
P O
W E
R H
O U
S E L
A Y
O U
T E
Q U
IP
M E
N T P
L A
E-104
S3
(SX5)
EXCITER
SEE NOTES 6, 9, 17, 18
SEE NOTE 16
CONTROL CABINET
DIGITAL GOVERNOR
SEE NOTES 12, 13
CABLE TRAY
NEW OVERHEAD
SEE NOTE 11
NEW BUS DUCT
SEE NOTE 11
NEW EXCITER CABINETSEE NOTE 10
S3FB1
(SX6)
EXCITER
SEE NOTE 11
NEW BUS DUCT
SEE NOTE 11
NEW EXCITER CABINET
MAIN UNIT 7
CONTINUES TO
REFERENCE:
NOTES:
PANEL
PATCH
S3FP1
RTU3
7-9, 15
NOTES
SEE
DRILL
CORE
P .K
E L L E
R
SEE NOTES 4-6, 9 & 14
S3FB2
SEE NOTE 11
RIGGING
NEW BRUSH
SEE NOTE 11
RIGGING
NEW BRUSH
M A
IN
U
N
IT
S I
N S
T A
L L
K
C H
E N
S T
E V
E N R
M
IL
E S P .E
NOTE 20
(CE32.1, CE32.2, CE32.3)
NEW DC PANELS
WIREWAY
SFN/RTU CABINET
RELOCATED TO
NEW RTU
CONDUIT CAN BE PROVIDED AS REQUESTED.
FIO DRAWINGS FOR ADDITIONAL EXISTING EMBEDDED
(UNITS 5&6 DETAILS EL 287.0) MDP-2.1-6-1G1/6
(U6 DS HALF EL 287.0) MDP-2.1-6-1G1/4
(U6 DS HALF EL 287.0) MDP-2.1-6-1G1/3
(U5 US HALF EL 287.0) MDP-2.1-6-1G1/2
(U5 DS HALF EL 287.0) MDP-2.1-6-1G1/1
SEE FIO DRAWINGS
SC-BOARD CONTROLS.
CONDUIT AND CABLE AS NEEDED FOR NEW S-BOARD AND
2. REUSE EXISTING ROUTING AND INSTALL ADDITIONAL
1. ABBREVIATIONS, NOTES AND LEGEND ON DRAWINGS E-102.
1-5, 9, 14
SEE NOTES
CONDUIT
MU FOCN
NOTE 21
CABINET (BPA3)
NEW BPA RELAYING
R
E V
IS
E D P
E R A
M E
N D
M E
N T
KEY PLAN
PARTIAL PLAN EL 287 BAYS 5 & 6
SS-07
BKR
GEN
P -7
CH42
P -8
PENETRATION
EXISTING FLOOR/CEILING
A7A8
COILING DOOR
OVERHEAD
DRAIN (TYP.)
C L C L
MAIN UNITS
UNIT 7CL
DN
CH01.1 PANEL
CL
DN
BLOCK OUT
LOUVERED
UNIT 8CL
SEE NOTES 12, 13
CABLE TRAY
OVERHEAD
EXISTING
P -9
C L
FISH
PUMP-
HOUSE
F L
O W
BKR
GEN
ASSEMBLY
BAY
UNIT
STATION
SERVICE
BAY
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
EL 287EL 287
A-1A-2P-1P-2P-3P-4P-5P-6P-7P-8P-9P-10P-11P-12P-13P-14P-15
TQ3.2
BUS 2
SQ3
TO EL 267
480V CABLES
TRAYS FOR
EXISTING 18"
GND. BUS
4'' EXP.
EXISTING
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
D A
T E
A P
P R
®of Engineers
US Army Corps of Engineers
US Army Corps
IS
S
U E D
A T
E
W A
L L
A W
A L L
A
W A
S H
IN
G T
O N
WALLA WALLA DISTRICT
c p w w o r k p w n w p d m s
M D
P
E
V
X X d g n
D E S
E
D A
E
P
L O
T T
E D
C O
L U
M B
IA
R
IV
E R
M C
N A
R Y L
O C
K A
N D D
A M
W E
F
R
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
W A
L L
A W
A L L
A D
IS
T R
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
P O
R T
L A
N D
O R
E G
O N
IDENTIFICATION
SHEET
VOLUME 1
P O
W E
R H
O U
S E E
X C
IT
E R
S
G O
V E
R N
O R
S P
O W
E R
H O
U S
E C
O N
T R
O L S U
P G
R A
D E
8'0 4' 16'
S
P .5
E -1
V
X X .d g n
D
W
IL
L
IA
M S
E L
P O
W E
R H
O U
S E L
A Y
O U
T E
Q U
IP
M E
N T P
L A
E-105
S4
TO MAIN UNIT 9
CONTINUES
SEE NOTE 11
NEW BUS DUCT
(SX8)
EXCITER
SEE NOTE 11
NEW EXCITER CABINET
PANEL
PATCH
S4FP1
S4FB1
NOTE 10
SEE
SEE NOTES 12, 13
CABLE TRAY
NEW OVERHEAD
SEE NOTES 1-5, 9, 14, 15
MU FOCN CONDUIT
(SX7)
EXCITER
SEE NOTE 11
NEW BUS DUCT
SEE NOTE 11
NEW EXCITER CABINET
SEE NOTES 1-5,9,14
MU FOCN CONDUIT
SEE NOTES 6, 9, 17, 18
SEE NOTE 16
CONTROL CABINET
DIGITAL GOVERNOR
NOTES:
RTU4
REFERENCES:
PLAN EL 287, BAYS 7 & 8MDP-1.46-6-1E40/1
P .K
E L L E
R
4-6, 9, 14
SEE NOTES
S4FB2
SEE NOTE 11
RIGGING
NEW BRUSH
SEE NOTE 11
RIGGING
NEW BRUSH
M A
IN
U
N
IT
S I
N S
T A
L L
K
C H
E N
S T
E V
E N R
M
IL
E S P .E
NOTE 20
(CE42.1, CE42.2, CE42.3)
NEW DC PANELS
WIREWAY
SFN/RTU CABINET
RELOCATED TO
NEW RTU
CONDUIT CAN BE PROVIDED AS REQUESTED.
FIO DRAWINGS FOR ADDITIONAL EXISTING EMBEDDED
(UNITS 7&8 DETAILS EL 287.0) MDP-2.1-6-1H1/5
(U8 US HALF EL 287.0) MDP-2.1-6-1H1/4
(U8 DS HALF EL 287.0) MDP-2.1-6-1H1/3
(U7 US HALF EL 287.0) MDP-2.1-6-1H1/2
(U7 DS HALF EL 287.0) MDP-2.1-6-1H1/1
SEE FIO DRAWINGS
SC-BOARD CONTROLS.
CONDUIT AND CABLE AS NEEDED FOR NEW S-BOARD AND
2. REUSE EXISTING ROUTING AND INSTALL ADDITIONAL
1. ABBREVIATIONS, NOTES AND LEGEND ON DRAWINGS E-102.
7-9, 15
SEE NOTES
CORE DRILL
NOTE 21
CABINET (BPA4)
NEW BPA RELAYING
R
E V
IS
E D P
E R A
M E
N D
M E
N T
KEY PLAN
PARTIAL PLAN EL 287 BAYS 7 & 8
CL
CL
P -9
C L
FISH
PUMP-
HOUSE
F L
O W
STATION
SERVICE
BAY
UNITUNIT
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
P-15 P-14 P-13 P-12 P-11 P-10 P-9 P-8 P-7 P-6 P-5 P-4 P-3 P-2 P-1 A-2
ASSEMBLY
BAY
A-1
C L P -1
C L P -1
BKR
GEN
A10
CH52
A9
CL
MAIN UNITS
SS-09
DN
TOILET
EL 287EL 287
TO EL. 267
FOR 480V CABLES
EXISTING 18'' TRAYS
BLOCK OUT
LOUVERED
SEE NOTES 12, 13
CABLE TRAY
OVERHEAD
EXISTING
UNIT 10
UNIT 9
PULL BOX
SS FOCN CONDUIT
(TYP.)
DRAIN
PWR J-BOX
SJ9.1 DC
SJ9.1C
CLR
PULL BOX
CONDUIT
SS FOCN
BUS 2
SJ9.1
BUS 1
SJ3.1
TQ3.1
BUS 1
SQ3
HRG
COILING DOOR
OVERHEAD
SQ3C
HRG
BKR
GEN
8'0 4' 16'
S
P .5
E -1
V
X X .d g n
D
W
IL
L
IA
M S
E L
P O
W E
R H
O U
S E L
A Y
O U
T E
Q U
IP
M E
N T P
L A
E-106
(SX9)
EXCITER
SEE NOTES 12, 13
CABLE TRAY
NEW OVERHEAD
SEE NOTE 11
NEW EXCITER CABINET
SEE NOTE 11
NEW BUS DUCT
SEE NOTES 1-5, 9, 14
MU FOCN CONDUIT
S5FB1
SEE NOTE 11
CABINET
NEW EXCITER
SEE NOTE 11
NEW BUS DUCT
(SX10)
EXCITER
SEE NOTE 16
CONTROL CABINET
DIGITAL GOVERNOR
PANEL
PATCH
S5FP1
SCALE: NTS
S5
SEE NOTE 10
MAIN UNIT 11
CONTINUES TO
NOTES 1-3
SEE
CONDUIT
SS FOCN
SEE NOTES 6, 9, 17 & 18
RTU5
SEE NOTES 7-9, 15
CORE DRILL
P .K
E L L E
R
4-6, 9, & 14
SEE NOTES
S5FB2
SEE NOTE 11
RIGGING
NEW BRUSH SEE NOTE 11
RIGGING
NEW BRUSH
M A
IN
U
N
IT
S
I
N S
T A
L L
NOTES:
PLAN EL 287.0, BAYS 9 & 10MDP-1.46-6-1E40/1
REFERENCE:
K
C H
E N
S T
E V
E N R
M
IL
E S P .E
NOTE 20
(CE52.1, CE52.2, CE52.3)
NEW DC PANELS
WIREWAY
SFN/RTU CABINET
RELOCATED TO
NEW RTU
CONDUIT CAN BE PROVIDED AS REQUESTED.
FIO DRAWINGS FOR ADDITIONAL EXISTING EMBEDDED
(UNITS 9&10 DETAILS EL 287.0) MDP-1.3-6-1J1/8
(U10 US HALF EL 287.0) MDP-1.3-6-1J1/5
(U10 DS HALF EL 287.0) MDP-1.3-6-1J1/4
(U9 US HALF EL 287.0) MDP-1.3-6-1J1/3
(U9 DS HALF EL 287.0) MDP-1.3-6-1J1/2
(U9/U10 EL 267.5) MDP-1.3-6-1J1/1
SEE FIO DRAWINGS
SC-BOARD CONTROLS.
CONDUIT AND CABLE AS NEEDED FOR NEW S-BOARD AND
2. REUSE EXISTING ROUTING AND INSTALL ADDITIONAL
1. ABBREVIATIONS, NOTES AND LEGEND ON DRAWINGS E-102.
R
E V
IS
E D P
E R A
M E
N D
M E
N
TNOTE 21
CABINET (BPA5)
NEW BPA RELAYING
KEY PLAN
PARTIAL PLAN EL 287 BAYS 9 & 10
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
D A
T E
A P
P R
®of Engineers
US Army Corps of Engineers
US Army Corps
IS
S
U E D
A T
E
W A
L L
A W
A L L
A
W A
S H
IN
G T
O N
WALLA WALLA DISTRICT
c p w w o r k p w n w p d m s
M D
P
E
V
X X d g n
D E S
E
D A
E
P
L O
T T
E D
C O
L U
M B
IA
R
IV
E R
M C
N A
R Y L
O C
K A
N D D
A M
W E
F
R
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
W A
L L
A W
A L L
A D
IS
T R
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
P O
R T
L A
N D
O R
E G
O N
IDENTIFICATION
SHEET
VOLUME 1
P O
W E
R H
O U
S E E
X C
IT
E R
S
G O
V E
R N
O R
S P
O W
E R
H O
U S
E C
O N
T R
O L S U
P G
R A
L
O W
ASSEMBLY
BAY
UNIT
STATION
SERVICE
BAY
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
UNIT
P -1
C L
P -1
C L
P -1
C L
FISH
PUMP-
HOUSE
CL
P-3P-4P-5P-6P-7P-8P-9P-10P-11P-12P-13P-14P-15 A-1A-2P-1P-2
TO EL 267
FOR 480V CABLES
EXISTING 18'' TRAYS
SS-13
A13A14
CH72
UNIT 13CL
CLMAIN UNITS
EL 287
DN
EL 287
SEE NOTES 12, 13
CABLE TRAY
OVERHEAD
EXISTING
UNIT 14
BLOCK OUT
LOUVERED
BKR
GEN
EXP. GND. BUS
EXISTING 4''
DN
BKR
GEN
SEE NOTE 14
CEILING/FLR BLOCKOUT
BUS 1
SQ4TQ4.1
PULL BOX
CONDUIT
SS FOCN
HRG
SQ4C
HRG
DOOR
COILING
OVERHEAD
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
D A
T E
A P
P R
®of Engineers
US Army Corps of Engineers
US Army Corps
IS
S
U E D
A T
E
W A
L L
A W
A L L
A
W A
S H
IN
G T
O N
WALLA WALLA DISTRICT
c p w w o r k p w n w p d m s
M D
P
E
V
X X d g n
D E S
E
D A
E
P
L O
T T
E D
C O
L U
M B
IA
R
IV
E R
M C
N A
R Y L
O C
K A
N D D
A M
W E
F
R
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
W A
L L
A W
A L L
A D
IS
T R
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
P O
R T
L A
N D
O R
E G
O N
IDENTIFICATION
SHEET
VOLUME 1
P O
W E
R H
O U
S E E
X C
IT
E R
S
G O
V E
R N
O R
S P
O W
E R
H O
U S
E C
O N
T R
O L S U
P G
R A
D E
8'0 4' 16'
SEE NOTE 11
NEW BUS DUCT
S
P .5
E -1
V
X X .d g n
D
W
IL
L
IA
M S
E L
P O
W E
R H
O U
S E L
A Y
O U
T E
Q U
IP
M E
N T P
L A
E-108
6,9,16,17
SEE NOTES
SEE NOTES 1-5, 9, 14
MU FOCN CONDUIT
SEE NOTE 11
NEW EXCITER CABINET
SEE NOTE 11
NEW BUS DUCT
SEE NOTES 12, 13
CABLE TRAY
NEW OVERHEAD
(SX13)
EXCITER
S7FB1
PANEL
PATCH
S7FP1
SEE NOTE 11
NEW EXCITER CABINET
SEE NOTE 16
CONTROL CABINET
DIGITAL GOVERNOR
(SX14)
EXCITER
SEE NOTES 1-5, 9, 14, 15
MU FOCN CONDUIT
S7 NOTES 1-3
SEE
CONDUIT
SS FOCN
RTU7
PLAN EL 287, BAYS 13 & 14MDP-1.46-6-1E40/1
REFERENCE:
NOTE:
SEE NOTES 7-9, 15
CORE DRILL
P .K
E L L E
R
4-6, 9, 14
SEE NOTES
S7FB2
SEE NOTE 11
RIGGING
NEW BRUSH
SEE NOTE 11
RIGGING
NEW BRUSH
M A
IN
U
N
IT
S
I
N S
T A
L L
K
C H
E N
S T
E V
E N R
M
IL
E S P .E
NOTE 20
(CE72.1, CE72.2, CE72.3)
NEW DC PANELS
WIREWAY
SEE NOTE 10
SFN/RTU CABINET
RELOCATED TO
NEW RTU
CONDUIT CAN BE PROVIDED AS REQUESTED.
FIO DRAWINGS FOR ADDITIONAL EXISTING EMBEDDED
(UNITS 13 & 14 DETAILS EL 287.0) MDP-1.3-6-1L1/6
(U14 US HALF EL 287.0) MDP-1.3-6-1L1/4
(U14 DS HALF EL 287.0) MDP-1.3-6-1L1/3
(U13 US HALF EL 287.0) MDP-1.3-6-1L1/2
(U13 DS HALF EL 287.0) MDP-1.3-6-1L1/1
SEE FIO DRAWINGS
SC-BOARD CONTROLS.
CONDUIT AND CABLE AS NEEDED FOR NEW S-BOARD AND
2. REUSE EXISTING ROUTING AND INSTALL ADDITIONAL
1. ABBREVIATIONS, NOTES AND LEGEND ON DRAWINGS E-102.
R E
V
IS
E D P
E R A
M E
N D
M E
N T
NOTE 21
CABINET (BPA6)
NEW BPA RELAYING
KEY PLAN
PARTIAL PLAN EL 287 BAYS 13 & 14
G R G R G R G R
ALLIS-CHALMERS
G R G R G R G R
ALLIS-CHALMERS
(4 PLACES)
SWINGING PANEL
3" 28" 56'' 28" 3" 3" 28" 56'' 28" 3"
(4 PLACES)
SWINGING PANEL
(A_5)*(A_5)*
8 10
8990899090
21 22
201918
(A_4)*(A_1)* (A_1)* (A_4)*
899089908990
35 36
21 22
201918
CONTRACTION JOINT
QUARRY TILE
32'-8"
1/4" 7 3/4" 28" 28" 28" 28" 28" 7 3/4" 1/4"
3"
9'-10"13'-0"9'-10"
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
D A
T E
A P
P R
®of Engineers
US Army Corps of Engineers
US Army Corps
IS
S
U E D
A T
E
W A
L L
A W
A L L
A
W A
S H
IN
G T
O N
WALLA WALLA DISTRICT
c p w w o r k p w n w p d m s
M D
P
E
V
X X d g n
D E S
E
D A
E
P
L O
T T
E D
C O
L U
M B
IA
R
IV
E R
M C
N A
R Y L
O C
K A
N D D
A M
W E
F
R
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
W A
L L
A W
A L L
A D
IS
T R
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
P O
R T
L A
N D
O R
E G
O N
IDENTIFICATION
SHEET
VOLUME 1
P O
W E
R H
O U
S E E
X C
IT
E R
S
G O
V E
R N
O R
S P
O W
E R
H O
U S
E C
O N
T R
O L S U
P G
R A
AMERICAN GOVERNOR
D
P .5
E -2
V
X X .d g n
E-202
K
C H
E N
D
W
IL
L
IA
M S
0 1' 2'
IN
S
T A
L L
S -S
S
W
IT
C H
B O
A R
D
AMERICAN GOVERNOR
15 16 17 5 5 5 7 9
6 6 6 8 10
11 12 13 14 15
36353433
31 32
33 34 35 36
21 22 23
1 1
5 5 5 7 9
6 6 6 8 10
11 12 13 14 15
EVEN UNITS ODD UNITS
GSU XFMR
ANNUNCIATOR HORN
18 24
S11 S12 S13 S14 S15 S16 S17
21 22 23
27 27
17 1920
2626 26
29 29
26 2626 26 26
1 1 1 1 1
DOOR
PANEL
ODD UNITS
PANEL
GSU XFMR
PANEL
EVEN UNITS
DOOR
S17 S1R6 S1R5 S1R4 S1R3 S1R2 S11
15 16 17
(A4 SIMILAR)
LEFT HAND GOVERNOR A2
(S2 SIMILAR)
GENERATOR SWITCHBOARD S1
(A3 SIMILAR)
RIGHT HAND GOVERNOR A1
(S2 SIMILAR)
GENERATOR SWITCHBOARD S1 REAR PANELS
1'-7"
-1 /4
4-1/4"
-1 /4
42 42
P .K
E L L E
R
S T
E V
E N R
M
IL
E S P .E
F R
O N
T A
R R
A N
G E
M E
N T
NOTE 1 NOTE 1
NOTES:
LOCATED WITHIN EASY REACH.
TOUCHSCREENS & CONTROL SWITCHES SHALL BE
3. ITEMS IN BOLD ARE TO BE INSTALLED. HMI
SWITCH DOES NOT EXIST ON S4 AND S6 BOARDS.
AND S5 (U9) ONLY. XFMR LINE BKR CONTROL
2. STATION SERVICE TAPS ASSOCIATED WITH S2 (U3)
1. DISCONNECT, RELOCATE AND REUSE DEVICES.
REFERENCES:
AND GOV CABINETS
SWITCHBOARD S1 MDP-5-6-9E4/2
AND GOV CABINETS
SWITCHBOARD S1 MDP-2.2-6-9G4/2
92. INDICATING LAMP (GREEN LENS) 115V
91. INDICATING LAMP (AMBER LENS) 125V
90. INDICATING LAMP (GREEN LENS) 125V
89. INDICATING LAMP (RED LENS) 125V
88. INDICATING LAMP (RED LENS) 115V
LEGEND FOR GOVERNORS A1 AND A2:
WITH INTEGRATED LIGHTS (RED/GRN) - ELECTROSWITCH OR EQUIVALENT (FUTURE)
43. GSU TRANSFORMER MOTOR OPERATED DISCONNECT (MOD) CONTROL SWITCH (_XM)
33. GOVERNOR SPEED ADJUST SWITCH (RAISE/LOWER) - ELECTROSWITCH SERIES 24 (SPRING RETURN)
36. EXCITER VOLTAGE ADJUST (RAISE/LOWER) - ELECTROSWITCH SERIES 24 (SPRING RETURN)
25. XFMR LINE LOCKOUT RELAY (86L) - ELECTROSWITCH SERIES 24
32. GOVERNOR GATE POSITION / LIMIT (%) - YOKOGAWA OR EQUIVALENT (4 1/4")
34. GOVERNOR GATE LIMIT ADJUST SWITCH (RAISE/LOWER) - ELECTROSWITCH SERIES 24 (SPRING RETURN)
22. GENERATOR ELECTRICAL LOCKOUT RELAY (86GX) - ELECTROSWITCH SERIES 24
23. GENERATOR DIFFERENTIAL LOCKOUT RELAY (87GX) - ELECTROSWITCH SERIES 24
20. GENERATOR EMERGENCY STOP SWITCH (5E) - ELECTROSWITCH SERIES 24 (RED PUSH-TO-TURN)
26. TEST SWITCHES - ABB-FT1 OR EQUIVALENT
31. GOVERNOR SPEED SETPOINT (RPM) - YOKOGAWA OR EQUIVALENT (4 1/4")
37. 120VAC ELECTRICAL OUTLET WITH COVER
38. DIGITAL IRIG-B CLOCK - SEL-3401 (IRIG-B DISTRIBUTED VIA PTP FROM SEL-AXION) (GFE)
39. WALL MOUNTED TELEPHONE
40. HOT LINE INDICATING LIGHT (WHITE)
21. GENERATOR TURBINE LOCKOUT RELAY (86GT) - ELECTROSWITCH SERIES 24
35. EXCITER SELECTOR SWITCH (AUTO/MANUAL) - ELECTROSWITCH SERIES 24 (MAINTAINED)
LOCATED IN REAR PANELS (S_R_) (GFE)
41. GENERATOR AND TRANSFORMER INTEGRATED I/O CONTROLLERS - SEL-AXION-2240
(LIGHTS ONLY)
30. STATION SERVICE BREAKER STATUS INDICATION (RED/GRN) - ELECTROSWITCH OR EQUIVALENT
ELECTROSWITCH SERIES 24P (SPRING RETURN)
24. XFMR 230KV BREAKER CONTROL SWITCH (52XM) WITH INTEGRATED LIGHTS (RED/GRN) -
ELECTROSWITCH SERIES 24P (MAINTAINED)
19. GENERATOR CONTROL TRANSFER SWITCH (43LR) WITH INTEGRATED LIGHT (BLU) -
42. GOVERNOR START/STOP SWITCH (START/STOP) - ELECTROSWITCH SERIES 24 (SPRING RETURN)
27. GENERATOR MULTIFUNCTION RELAY (11G) - SEL-700G1 (REDUNDANT) (GFE)
28. GENERATOR MULTIFUNCTION METER (MFM) - SEL-735 (GFE)
29. XFMR MULTIFUNCTION RELAY (11T) - SEL-7873E (REDUNDANT) (GFE)
LEGEND FOR SWITCHBOARD S1:
1. UNIT LABEL
5. GENERATOR AMMETER (AM) - ABC PHASES - YOKOGAWA DUALVUE OR EQUIVALENT (4 1/4")
6. GENERATOR VOLTMETER (VM) - ABC PHASES - YOKOGAWA DUALVUE OR EQUIVALENT (4 1/4")
7. GENERATOR WATTMETER (WM) - YOKOGAWA OR EQUIVALENT (4 1/4")
8. GENERATOR VARMETER (VARM) - YOKOGAWA OR EQUIVALENT (4 1/4")
9. EXCITER FIELD CURRENT (ADC) - YOKOGAWA DUALVUE OR EQUIVALENT (4 1/4")
10. EXCITER FIELD VOLTAGE (VDC) - YOKOGAWA DUALVUE OR EQUIVALENT (4 1/4")
12. SYNCH INCOMING VOLTMETER (VM) - YOKOGAWA DUALVUE OR EQUIVALENT (4 1/4")
13. SYNCH SCOPE (SS) - YOKOGAWA OR EQUIVALENT (4 1/4")
14. SYNCH RUNNING VOLTMETER (VM) - YOKOGAWA DUALVUE OR EQUIVALENT (4 1/4")
16. GENERATOR RUN INDICATING LIGHT (WHITE)
11. SYNCH INCOMING FREQUENCY METER (FM) - YOKOGAWA DUALVUE OR EQUIVALENT (4 1/4")
15. SYNCH RUNNING FREQUENCY METER (FM) - YOKOGAWA DUALVUE OR EQUIVALENT (4 1/4")
ELECTROSWITCH SERIES 24P (MAINTAINED)
18. GENERATOR SYNCHRONIZING SWITCH (52SS) WITH INTEGRATED LIGHT (WHT) -
ELECTROSWITCH SERIES 24P (SPRING RETURN)
17. GENERATOR BREAKER CONTROL SWITCH (52XJ) WITH INTEGRATED LIGHTS (RED/GRN) -
4. REAL TIME AUTOMATION CONTROLLER - SEL-RTAC-3555 (5 1/4" x 19") (GFE)
2. TRANSFORMER AND BREAKER ANN/SER HMI (GFE)
3. GENERATOR ANN/SER HMI (GFE)
NOTE 1
25 33
NOTE 1
R E
V
IS
E D P
E R A
M E
N D
M E
N T
42. NOT USED
41. NOT USED
40. 13,800 VOLT GOV OIL PUMP #3 CONTROL SWITCH
39. 13,800 VOLT GOV OIL PUMP #2 CONTROL SWITCH
38. 480 VOLT GOV OIL PUMP #1 CONTROL SWITCH
37. NOT USED
36. GEN COOLING WATER VALVE CONTROL SWITCH
35. TURBINE GUIDE BRG LUBRICATING OIL PUMP CONTROL SWITCH
34. EMERGENCY HEAD GATE LOWERING CONTROL SWITCH
33. THRUST BEARING OIL PUMP CONTROL SWITCH, NOTE 1
32. NOT USED
31. NOT USED
30. NOT USED
29. GOV OIL SHUT-OFF INDICATOR ASSEMBLY
28. GOV OIL SHUT-OFF VALVE HANDWHEEL
27. NOT USED
26. NOT USED
25. AIR BRAKE VALVE CONTROL SWITCH, NOTE 1
24. STOP NUT CONTROLLER
23. STOP NUT POSITION INDICATOR
22. DRAFT TUBE VACUUM & PRESSURE GAUGE (34-0-80 FT OF WATER)
21. SCROLL CATE PRESSURE GAUGE 0-115 FT OF WATER
20. TURBINE GUIDE BRG TEMPERATURE INDICATOR
19. TURBINE GUIDE BRG OIL TEMPERATURE INDICATOR
18. UPPER GUIDE BRG TEMPERATURE INDICATOR
17. THRUST BRG TEMPERATURE INDICATOR, NOTE 1
16. THRUST BRG OIL TEMPERATURE INDICATOR, NOTE 1
15. LOWER GUIDE BRG TEMPERATURE INDICATOR, NOTE 1
14. NOT USED
13. NOT USED
12. NOT USED
11. NOT USED
10. GOVERNOR OIL PRESSURE GAUGE
9. THRUST BEARING HP LIFT PUMP DISCHARGE PRESSURE, NOTE 1
8. AIR BRAKE PRESSURE GAUGE - DUPLEX
7. NOT USED
6. NOT USED
5. NOT USED
4. GOVERNOR HMI
3. NOT USED
2. NOT USED
1. NOT USED
S1 & S2 CABINET FRONT LAYOUT
21 22 22 31 32 36 34
26 27 28
252423 23 24 25
282726
29 30
31 32 36 34 21 22 22
EL 287
FLOOR LINE
FINISHED
9'-6"13'-0"9'-6"
32'-0"
3"
JOINT
CONTRACTION
QUARRY TILE
1/4"1/4"
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
D A
T E
A P
P R
®of Engineers
US Army Corps of Engineers
US Army Corps
IS
S
U E D
A T
E
W A
L L
A W
A L L
A
W A
S H
IN
G T
O N
WALLA WALLA DISTRICT
c p w w o r k p w n w p d m s
M D
P
E
V
X X d g n
D E S
E
D A
E
P
L O
T T
E D
C O
L U
M B
IA
R
IV
E R
M C
N A
R Y L
O C
K A
N D D
A M
W E
F
R
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
W A
L L
A W
A L L
A D
IS
T R
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
P O
R T
L A
N D
O R
E G
O N
IDENTIFICATION
SHEET
VOLUME 1
P O
W E
R H
O U
S E E
X C
IT
E R
S
G O
V E
R N
O R
S P
O W
E R
H O
U S
E C
O N
T R
O L S U
P G
R A
D E
2'1'0'
AMERICAN GOVERNOR AMERICAN GOVERNOR
S31
ODD UNITS
GSU XFMR
ANNUNCIATOR HORN
EVEN UNITS
31 32
11 12 13 14 15
108666
5 5 5 7 9
22 23
27 27
36353433
29 29
33 34 35 36
21 22 23
27 27
97555
106 6 6 8
11 12 13 14
31 32
S34 S35 S36 S37S33S32
26 26 26 26 26
26 26
26 26
14 15
1 1 1 1 1
S37 S3R6 S3R5 S3R4 S3R3 S3R2 S31
DOOR
PANEL
ODD UNITS
PANEL
GSU XFMR
PANEL
EVEN UNITS
DOOR
14 15
(S4-S7 SIMILAR)
GENERATOR SWITCHBOARD S3
(A8, A10, A12, A14 SIMILAR)
LEFT HAND GOVERNOR A6
(A7, A9, A11, A13 SIMILAR)
RIGHT HAND GOVERNOR A5
(S4-S7 SIMILAR)
GENERATOR SWITCHBOARD S3 REAR PANELS
42 42
NOTES:
SHALL BE LOCATED WITHIN EASY REACH.
TOUCHSCREENS AND CONTROL SWITCHES
3. ITEMS IN BOLD ARE TO BE INSTALLED. HMI
ON S4 AND S6 BOARDS.
BREAKER CONTROL SWITCH DOES NOT EXIST
(UNIT 3) AND S5 (UNIT 9) ONLY. XFMR LINE
2. STATION SERVICE TAPS ASSOCIATED WITH S2
1. DISCONNECT, RELOCATE AND REUSE DEVICES.
E V
E N R
M
IL
E S P
E
A N
S
P .5
E -2
V
X X .d g n
D
W
IL
L
IA
M S
K
C H
E N
P .K
E L L E
R
IN
S
T A
L L
F R
O N
T A
R R
A N
G E
M E
N T
S -S
S
W
IT
C H
B O
A R
E-203
NOTE 1 NOTE 1
LEGEND FOR GOVERNORS A5 AND A6:
1'-7"
"4
1. UNIT LABEL
5. GENERATOR AMMETER (AM) - ABC PHASES - YOKOGAWA DUALVUE OR EQUIVALENT (4 1/4")
6. GENERATOR VOLTMETER (VM) - ABC PHASES - YOKOGAWA DUALVUE OR EQUIVALENT (4 1/4")
7. GENERATOR WATTMETER (WM) - YOKOGAWA OR EQUIVALENT (4 1/4")
8. GENERATOR VARMETER (VARM) - YOKOGAWA OR EQUIVALENT (4 1/4")
9. EXCITER FIELD CURRENT (ADC) - YOKOGAWA DUALVUE OR EQUIVALENT (4 1/4")
10. EXCITER FIELD VOLTAGE (VDC) - YOKOGAWA DUALVUE OR EQUIVALENT (4 1/4")
12. SYNCH INCOMING VOLTMETER (VM) - YOKOGAWA DUALVUE OR EQUIVALENT (4 1/4")
13. SYNCH SCOPE (SS) - YOKOGAWA OR EQUIVALENT (4 1/4")
14. SYNCH RUNNING VOLTMETER (VM) - YOKOGAWA DUALVUE OR EQUIVALENT (4 1/4")
16. GENERATOR RUN INDICATING LIGHT (WHITE)
18. GENERATOR SYCHRONIZING SWITCH (52SS) WITH INTEGRATED LIGHT (WHT) - ELECTROSWITCH SERIES 24P (MAINTAINED)
19. GENERATOR CONTROL TRANSFER SWITCH (43LR) WITH INTEGRATED LIGHT (BLU) - ELECTROSWITCH SERIES 24P (MAINTAINED)
26. TEST SWITCHES - ABB-FT1 OR EQUIVALENT
30. STATION SERVICE BREAKER STATUS INDICATION (RED/GRN) - ELECTROSWITCH OR EQUIVALENT (LIGHTS ONLY)
31. GOVERNOR SPEED SETPOINT (RPM) - YOKOGAWA OR EQUIVALENT (4 1/4")
32. GOVERNOR GATE POSITION / LIMIT (%) - YOKOGAWA OR EQUIVALENT (4 1/4")
33. GOVERNOR SPEED ADJUST SWITCH (RAISE/LOWER) - ELECTROSWITCH SERIES 24 (SPRING RETURN)
36. EXCITER VOLTAGE ADJUST (RAISE/LOWER) - ELECTROSWITCH SERIES 24 (SPRING RETURN)
37. 120VAC ELECTRICAL OUTLET WITH COVER
39. WALL MOUNTED TELEPHONE
40. HOT LINE INDICATING LIGHT (WHITE)
21. GENERATOR TURBINE LOCKOUT RELAY (86GT) - ELECTROSWITCH SERIES 24
23. GENERATOR DIFFERENTIAL LOCKOUT RELAY (87GX) - ELECTROSWITCH SERIES 24
25. XFMR LINE LOCKOUT RELAY (86L) - ELECTROSWITCH SERIES 24
11. SYNCH INCOMING FREQUENCY METER (FM) - YOKOGAWA DUALVUE OR EQUIVALENT (4 1/4")
15. SYNCH RUNNING FREQUENCY METER (FM) - YOKOGAWA DUALVUE OR EQUIVALENT (4 1/4")
(SPRING RETURN)
17. GENERATOR BREAKER CONTROL SWITCH (52XJ) WITH INTEGRATED LIGHTS (RED/GRN) - ELECTROSWITCH SERIES 24P
(SPRING RETURN)
24. XFMR 230KV BREAKER CONTROL SWITCH (52XM) WITH INTEGRATED LIGHTS (RED/GRN) - ELECTROSWITCH SERIES 24P
22. GENERATOR ELECTRICAL LOCKOUT RELAY (86GX) - ELECTROSWITCH SERIES 24
20. GENERATOR EMERGENCY STOP SWITCH (5E) - ELECTROSWITCH SERIES 24 (RED PUSH-TO-TURN)
34. GOVERNOR GATE LIMIT ADJUST SWITCH (RAISE/LOWER) - ELECTROSWITCH SERIES 24 (SPRING RETURN)
35. EXCITER SELECTOR SWITCH (AUTO/MANUAL) - ELECTROSWITCH SERIES 24 (MAINTAINED)
38. DIGITAL IRIG-B CLOCK - SEL-3401 (IRIG-B DISTRIBUTED VIA PTP FROM SEL-AXION) (GFE)
42. GOVERNOR START/STOP SWITCH (START/STOP) - ELECTROSWITCH SERIES 24 (SPRING RETURN)
2. TRANSFORMER AND BREAKER ANN/SER HMI (GFE)
3. GENERATOR ANN/SER HMI (GFE)
4. REAL TIME AUTOMATION CONTROLLER - SEL-RTAC-3555 (5 1/4" x 19") (GFE)
27. GENERATOR MULTIFUNCTION RELAY (11G) - SEL-700G1 (REDUNDANT) (GFE)
28. GENERATOR MULTIFUNCTION METER (MFM) - SEL-735 (GFE)
29. XFMR MULTIFUNCTION RELAY (11T) - SEL-7873E (REDUNDANT) (GFE)
LOCATED IN REAR PANELS (S_R_) (GFE)
41. GENERATOR AND TRANSFORMER INTEGRATED I/O CONTROLLERS - SEL-AXION-2240
:LEGEND FOR SWITCHBOARD S3
WITH INTEGRATED LIGHTS (RED/GRN) - ELECTROSWITCH OR EQUIVALENT (FUTURE)
43. GSU TRANSFORMER MOTOR OPERATED DISCONNECT (MOD) CONTROL SWITCH (_XM)
R E
V
IS
E D P
E R A
M E
N D
M E
N
36. THRUST BEARING H.P. OIL PUMP CONTROL SWITCH
35. REMOVED
34. HEADGATE EMERGENCY LOWERING CONTROL SWITCH
33. THRUST BEARING HP LIFT PUMP DISCHARGE PRESSURE, NOTE 1
32. TURBINE BEARING OIL PUMP CONTROL SWITCH
31. GENERATOR COOLING WATER VALVE CONTROL SWITCH
30. DRAFT TUBE PRESSURE GAUGE
29. SCROLL CASE PRESSURE GAUGE
28. THRUST BEARING TEMPERATURE INDICATOR
27. THRUST BEARING OIL TEMPERATURE INDICATOR
26. GENERATOR LOWER GUIDE-BEARING TEMPERATURE INDICATOR
25. TURBINE BEARING TEMPERATURE INDICATOR
24. TURBINE BEARING OIL TEMPERATURE INDICATOR
23. GENERATOR UPPER GUIDE-BEARING TEMPERATURE INDICATOR
22. 300 GPM GOVERNOR OIL PUMP INDICATION
21. 150 GPM GOVERNOR OIL PUMP INDICATION
20. NOT USED
19. REMOVED
18. REMOVED
17. REMOVED
16. NOT USED
15. GENERATOR BRAKE CONTROL SWITCH, NOTE 1
14. CABINET LIGHT SWITCH, NOTE 1
13. REMOVED
12. REMOVED
11. REMOVED
10. REMOVED
9. REMOVED
8. REMOVED
7. REMOVED
6. NOT USED
5. REMOVED
4. GOVERNOR HMI, EXCITER HMI LOCATED AT SX-BOARD
3. GOVERNOR OIL PRESSURE GAUGE, NOTE 1
2. DUPLEX AIR BRAKE PRESSURE GAUGE, NOTE 1
1. REMOVED
NOTE 1 NOTE 1
1 1
S3 - S7 FRONT PANEL LAYOUT
ALLIS-CHALMERS
RGRRGRG G
39 40
18 19
21 10
(A_2)(A_1) **
(A_3) (A_4)
FLOOR LINE
SWINGING PANEL (4 PLACES)
9'-10"
3"2'-4"2'-4"2'-4"2'-4"3"
(A_5)
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
D A
T E
A P
P R
®of Engineers
US Army Corps of Engineers
US Army Corps
IS
S
U E D
A T
E
W A
L L
A W
A L L
A
W A
S H
IN
G T
O N
WALLA WALLA DISTRICT
c p w w o r k p w n w p d m s
M D
P
E D
V
X X d g n
D E S
E
D A
E
P
L O
T T
E D
C O
L U
M B
IA
R
IV
E R
M C
N A
R Y L
O C
K A
N D D
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
W A
L L
A W
A L L
A D
IS
T R
VOLUME 2
.S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
P O
R T
L A
N D
O R
E G
O N
P O
W E
R H
O U
S E E
X C
IT
E R
S W
E
F
R
G O
V E
R N
O R
S P
O W
E R
H O
U S
E C
O N
T R
O L S U
P G
R A
D E
M D
P .5
E
D
V
X X .d g n
ED501
-4 O
D D U
N
IT
S D
G A
C T
U A
T O
R
C A
B
IN
E T D
E T
A
IL
S
P .K
E L L E
R
K
C H
E N
D
W
IL
L
IA
E V
E N R
M
IL
E S P .E
R
M O
V A
L
SCALE: NTS
RG
RG
30 32
16 17
89 41
1311 12 6
3D CAM CONTROL CABINET4
THRUST BEARING OIL PUMP CONTROL SWITCH
6 TRANSFER VALVE INDICATOR & DRIVE MECH ASSEMBLY
NO
ITEM
VANE TILT INDICATOR ASSEMBLY (BLADE POSITION)
BYPASS VALVE SHUT-OFF SWITCH (CONTROL VALVE)
4160 VOLT GOV OIL PUMP #3 CONTROL SWITCH
480 VOLT GOV OIL PUMP #1 CONTROL SWITCH
4160 VOLT GOV OIL PUMP #2 CONTROL SWITCH39
REMARKSORDER NO
NAME
NO
15184
2-0208-
MK-801
USED FOR
MK-802
McNARY DAM PROJECT - UNITS 1 & 3
US DEPT OF THE ARMY CORPS OF ENGINEERS 2
15184
2-0208-
McNARY DAM PROJECT - UNITS 1 & 3
US DEPT OF THE ARMY CORPS OF ENGINEERS
TRANSFORMER COOLING WATER PUMP CONTROL SWITCH
15184
2-0208-
15184
2-0208-
GATE POSITION & GATE LIMIT INDICATOR
SPEED DROOP INDICATOR
GOV OIL PRESSURE GAUGE
SPEED CHANGER INDICATOR
THRUST BRG OIL TEMPERATURE INDICATOR
THRUST BRG TEMPERATURE INDICATOR
ELECTRIC TACHOMETER
GEN LOWER GUIDE BRG TEMPERATURE INDICATOR
INDICATING LAMP (RED LENS) 115V
AIR BRAKE PRESSURE GAUGE - DUPLEX
GEN UPPER GUIDE BRG TEMPERATURE INDICATOR
SPEED LEVEL (SYN) HANDWHEEL
GATE LIMIT HANDWHEEL
GOV OIL SHUT-OFF INDICATOR ASSEMBLY
GOV OIL SHUT-OFF VALVE HANDWHEEL
TURBINE GUIDE BRG LUBRICATING OIL PUMP CONTROL SWITCH
GEN COOLING WATER VALVE CONTROL SWITCH
SPEED DROOP HANDWHEEL
EMERGENCY HEAD GATE LOWERING CONTROL SWITCH
DRAFT TUBE VACUUM & PRESSURE GAUGE (34-0-80 FT OF WATER)
SCROLL CATE PRESSURE GAUGE 0-115 FT OF WATER
TURBINE GUIDE BRG OIL TEMPERATURE INDICATOR
TURBINE GUIDE BRG TEMPERATURE INDICATOR
GOV SHUT-DOWN SWITCH - RED HANDLE
TRANSFER VALVE CONTROL SWITCH
STOP NUT CONTROLLER
AIR BRAKE VALVE CONTROL SWITCH
MOUNTING OF TURBINE & GENERATOR INSTUMENTS
INDICATING LAMP (GREEN LENS) 125V
INDICATING LAMP (RED LENS) 125V
INDICATING LAMP (AMBER LENS) 125V
INDICATING LAMP (GREEN LENS) 115V
15184
2-0208-
EQUIPMENT LIST
SWINGING PANEL
LEGEND:
INDICATES ITEMS EXISTING TO REMAIN
RELOCATED AND RECONENCTED
INDICATED ITEMS TO BE DISCONNECTED,
INDICATES ITEMS TO BE REMOVED
REFERENCE:
ASSEMBLY (ALLIS-CHALMERS)
GOVERNOR INSTRUMENT PANELD2-570-333
R
E V
IS
E D P
E R A
M E
N D
M E
N T
NOTES:1
EXISTING SWITCH AND GAUGE LAYOUT.
1. RELOCATE CONTROL SWITCHES AND GAUGES. ALIGN WITH
NOTE 1
NOTE 1
NOTE 1
EL: RH PANEL ASSEMBLY UNITS 1 & 3 (MK 802)
R R
8 2110
ALLIS-CHALMERS
G
(A_3)* * *(A_4)(A_1)* (A_2)
R
G GR
38 39
8990 90
FLOOR LINE
19 2018
SWINGING PANEL (4 PLACES)
9'-10"
3"2'-4"2'-4"2'-4"2'-4"3"
(A_5)
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
D A
T E
A P
P R
®of Engineers
US Army Corps of Engineers
US Army Corps
IS
S
U E D
A T
E
W A
L L
A W
A L L
A
W A
S H
IN
G T
O N
WALLA WALLA DISTRICT
c p w w o r k p w n w p d m s
M D
P
E D
V
X X d g n
D E S
E
D A
E
P
L O
T T
E D
C O
L U
M B
IA
R
IV
E R
M C
N A
R Y L
O C
K A
N D D
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
W A
L L
A W
A L L
A D
IS
T R
.S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
P O
R T
L A
N D
O R
E G
O N
P O
W E
R H
O U
S E E
X C
IT
E R
S W
E
F
R
G O
V E
R N
O R
S P
O W
E R
H O
U S
E C
O N
T R
O L S U
P G
R A
D E
M D
P .5
E
D
V
X X .d
ED502
-4 E
V E
N U
N
IT
S D
G A
C T
U A
T O
R
C A
B
IN
E T D
E T
A
IL
S
P .K
E L L E
R
K
C H
E N
D
W
IL
L
IA
E V
E N R
M
IL
E S P
R
M O
V A
L
REMARKS
TRANSFER VALVE INDICATOR & DRIVE MECH ASSEMBLY
NO
ITEM
MK-802
15184
2-0208-
USED FOR ORDER NONO
SPEED CHANGER INDICATOR
GATE POSITION & GATE LIMIT INDICATOR
GOV OIL PRESSURE GAUGE
AIR BRAKE PRESSURE GAUGE - DUPLEX
THRUST BRG OIL TEMPERATURE INDICATOR
THRUST BRG TEMPERATURE INDICATOR
GEN LOWER GUIDE BRG TEMPERATURE INDICATOR
SPEED DROOP INDICATOR
ELECTRIC TACHOMETER
INDICATING LAMP (GREEN LENS) 125V
INDICATING LAMP (RED LENS) 125V
INDICATING LAMP (GREEN LENS) 115V
MOUNTING OF TURBINE & GENERATOR INSTUMENTS
INDICATING LAMP (AMBER LENS) 125V91
INDICATING LAMP (RED LENS) 115V
GEN UPPER GUIDE BRG TEMPERATURE INDICATOR
TURBINE GUIDE BRG LUBRICATING OIL PUMP CONTROL SWITCH
GEN COOLING WATER VALVE CONTROL SWITCH
EMERGENCY HEAD GATE LOWERING CONTROL SWITCH
GATE LIMIT HANDWHEEL
SPEED DROOP HANDWHEEL
4160 VOLT GOV OIL PUMP #3 CONTROL SWITCH
4160 VOLT GOV OIL PUMP #2 CONTROL SWITCH
TRANSFORMER COOLING WATER PUMP CONTROL SWITCH
480 VOLT GOV OIL PUMP #1 CONTROL SWITCH
SPEED LEVEL (SYN) HANDWHEEL
SCROLL CATE PRESSURE GAUGE 0-115 FT OF WATER
STOP NUT CONTROLLER
DRAFT TUBE VACUUM & PRESSURE GAUGE (34-0-80 FT OF WATER)
TURBINE GUIDE BRG OIL TEMPERATURE INDICATOR
TURBINE GUIDE BRG TEMPERATURE INDICATOR
GOV OIL SHUT-OFF INDICATOR ASSEMBLY
GOV OIL SHUT-OFF VALVE HANDWHEEL
TRANSFER VALVE CONTROL SWITCH
AIR BRAKE VALVE CONTROL SWITCH
GOV SHUT-DOWN SWITCH - RED HANDLE
VANE TILT INDICATOR ASSEMBLY (BLADE POSITION)
NAME
BYPASS VALVE SHUT-OFF SWITCH (CONTROL VALVE)
THRUST BEARING OIL PUMP CONTROL SWITCH
EQUIPMENT LIST
3D CAM CONTROL CABINET
McNARY DAM PROJECT - UNITS 1 & 3
US DEPT OF THE ARMY CORPS OF ENGINEERS 2
McNARY DAM PROJECT - UNITS 1 & 3
US DEPT OF THE ARMY CORPS OF ENGINEERS MK-801
15184
2-0208-2
1311 12
G R RG
16 17
16"8"0"
SWINGING PANEL
LEGEND:
INDICATES ITEMS EXISTING TO REMAIN
RELOCATED AND RECONENCTED
INDICATED ITEMS TO BE DISCONNECTED,
INDICATES ITEMS TO BE REMOVED
REFERENCE:
ASSEMBLY (ALLIS-CHALMERS)
GOVERNOR INSTRUMENT PANELD2-570-333
NOTES:1
EXISTING SWITCH AND GAUGE LAYOUT.
1. RELOCATE CONTROL SWITCHES AND GAUGES. ALIGN WITH
R E
V
IS
E D P
E R A
M E
N D
M E
N T
NOTE 1
NOTE 1
NOTE 1
EL: LH PANEL ASSEMBLY UNITS 2 & 4 (MK 801)
RGRG
19 20
*(A_1) *(A_4)
GR RG
FLOOR LINE
ALLIS-CHALMERS
SWINGING PANEL (4 PLACES)
(A_5)
9'-10"
3"2'-4"4'-8"2'-4"3"
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
D A
T E
A P
P R
®of Engineers
US Army Corps of Engineers
US Army Corps
IS
S
U E D
A T
E
W A
L L
A W
A L L
A
W A
S H
IN
G T
O N
WALLA WALLA DISTRICT
c p w w o r k p w n w p d m s
M D
P
E
V
X X d g n
D E S
E
D A
E
P
L O
T T
E D
C O
L U
M B
IA
R
IV
E R
M C
N A
R Y L
O C
K A
N D D
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
W A
L L
A W
A L L
A D
IS
T R
.S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
P O
R T
L A
N D
O R
E G
O N
P O
W E
R H
O U
S E E
X C
IT
E R
S W
E
F
R
G O
V E
R N
O R
S P
O W
E R
H O
U S
E C
O N
T R
O L S U
P G
R A
D E
M D
P .5
E -5
V
X X .d
E-501
-4 O
D D U
N
IT
S D
G A
C T
U A
T O
R
C A
B
IN
E T D
E T
A
IL
S
P .K
E L L E
R
K
C H
E N
D
W
IL
L
IA
M S
M D
P -1 .5
-6 -0
A /1
S T
E V
E N R
M
IL
E S P
16"8"0"
S
T A
L L
16 1715
91 91
MK-801
15184
2-0208-
MK-802
15184
2-0208-
McNARY DAM PROJECT - UNITS 1 & 3
US DEPT OF THE ARMY CORPS OF ENGINEERS 2
McNARY DAM PROJECT - UNITS 1 & 3
US DEPT OF THE ARMY CORPS OF ENGINEERS 2
USED FOR ORDER NONO REMARKS
NAME
EQUIPMENT LIST
NO
ITEM
AIR BRAKE PRESSURE GAUGE - DUPLEX8
GOV OIL PRESSURE GAUGE
GOV OIL SHUT-OFF INDICATOR ASSEMBLY
GOV OIL SHUT-OFF VALVE HANDWHEEL
SCROLL CATE PRESSURE GAUGE 0-115 FT OF WATER
AIR BRAKE VALVE CONTROL SWITCH
DRAFT TUBE VACUUM & PRESSURE GAUGE (34-0-80 FT OF WATER)
TURBINE GUIDE BRG OIL TEMPERATURE INDICATOR
TURBINE GUIDE BRG TEMPERATURE INDICATOR
GEN UPPER GUIDE BRG TEMPERATURE INDICATOR
EMERGENCY HEAD GATE LOWERING CONTROL SWITCH
TURBINE GUIDE BRG LUBRICATING OIL PUMP CONTROL SWITCH
GEN COOLING WATER VALVE CONTROL SWITCH
INDICATING LAMP (GREEN LENS) 125V
INDICATING LAMP (RED LENS) 125V
INDICATING LAMP (RED LENS) 115V
MOUNTING OF TURBINE & GENERATOR INSTUMENTS
INDICATING LAMP (GREEN LENS) 115V
3D CAM CONTROL CABINET94
DIGITAL GOVERNOR CONTROL CABINET6
THRUST BEARING HP LIFT PUMP DISCHARGE PRESSURE9
GEN LOWER GUIDE BRG TEMPERATURE INDICATOR
THRUST BRG OIL TEMPERATURE INDICATOR
THRUST BRG TEMPERATURE INDICATOR
THRUST BEARING OIL PUMP CONTROL SWITCH42
INDICATING LAMP (AMBER LENS) 125V91
ASSEMBLY (ALLIS-CHALMERS)
GOVERNOR INSTRUMENT PANELD2-570-333
REFERENCE:
LEGEND:
INDICATES GOVERMENT FURNISHED EQUIPMENT
INDICATED NEW WORK FROM RELOCATED ITEMS
INDICATES NEW WORK
INDICATES EXISTING EQUIPMENT
NOTE 1
NOTE 1
NOTES:
R E
V
IS
E D P
E R A
M E
N D
M E
N T
EXISTING SWITCH AND GAUGE LAYOUT.
1. RELOCATE CONTROL SWITCHES AND GAUGES. ALIGN WITH
NOTE 1
EL: RH PANEL ASSEMBLY UNITS 1 & 3 (MK 802)
19 20
RG
ALLIS-CHALMERS
*(A_4)
*(A_1)
G RGGR R
8990 8990
FLOOR LINE
SWINGING PANEL (4 PLACES)
(A_5)
9'-10"
3"2'-4"4'-8"2'-4"3"
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
D A
T E
A P
P R
®of Engineers
US Army Corps of Engineers
US Army Corps
IS
S
U E D
A T
E
W A
L L
A W
A L L
A
W A
S H
IN
G T
O N
WALLA WALLA DISTRICT
c p w w o r k p w n w p d m s
M D
P
E
V
X X d g n
D E S
E
D A
E
P
L O
T T
E D
C O
L U
M B
IA
R
IV
E R
M C
N A
R Y L
O C
K A
N D D
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
W A
L L
A W
A L L
A D
IS
T R
.S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
P O
R T
L A
N D
O R
E G
O N
P O
W E
R H
O U
S E E
X C
IT
E R
S W
E
F
R
G O
V E
R N
O R
S P
O W
E R
H O
U S
E C
O N
T R
O L S U
P G
R A
D E
M D
P .5
E -5
V
X X .d
E-502
-4 E
V E
N U
N
IT
S D
G A
C T
U A
T O
R
C A
B
IN
E T D
E T
A
IL
S
P .K
E L L E
R
K
C H
E N
D
W
IL
L
IA
M S
M D
P -1 .5
-6 -0
A /1
S T
E V
E N R
M
IL
E S P
16"8"0"
S
T A
L L
NOTE:
NO
ITEM
INDICATING LAMP (RED LENS) 125V
INDICATING LAMP (RED LENS) 115V
AIR BRAKE PRESSURE GAUGE - DUPLEX
INDICATING LAMP (GREEN LENS) 125V
DIGITAL GOVERNOR CONTROL CABINET
THRUST BEARING OIL PUMP CONTROL SWITCH
INDICATING LAMP (AMBER LENS) 125V
INDICATING LAMP (GREEN LENS) 115V
MOUNTING OF TURBINE & GENERATOR INSTUMENTS
EMERGENCY HEAD GATE LOWERING CONTROL SWITCH
TURBINE GUIDE BRG LUBRICATING OIL PUMP CONTROL SWITCH
GOV OIL SHUT-OFF INDICATOR ASSEMBLY
GOV OIL SHUT-OFF VALVE HANDWHEEL
GEN COOLING WATER VALVE CONTROL SWITCH
AIR BRAKE VALVE CONTROL SWITCH
THRUST BRG OIL TEMPERATURE INDICATOR
THRUST BRG TEMPERATURE INDICATOR
GOV OIL PRESSURE GAUGE
GEN LOWER GUIDE BRG TEMPERATURE INDICATOR
GEN UPPER GUIDE BRG TEMPERATURE INDICATOR
DRAFT TUBE VACUUM & PRESSURE GAUGE (34-0-80 FT OF WATER)
SCROLL CATE PRESSURE GAUGE 0-115 FT OF WATER
TURBINE GUIDE BRG OIL TEMPERATURE INDICATOR
TURBINE GUIDE BRG TEMPERATURE INDICATOR
USED FOR
MK-802
ORDER NONO
15184
2-0208-
McNARY DAM PROJECT - UNITS 1 & 3
US DEPT OF THE ARMY CORPS OF ENGINEERS
McNARY DAM PROJECT - UNITS 1 & 3
US DEPT OF THE ARMY CORPS OF ENGINEERS
MK-801
15184
2-0208-
REMARKS
94 3D CAM CONTROL CABINET
EQUIPMENT LIST
NAME
THRUST BEARING HP LIFT PUMP DISCHARGE PRESSURE
AMERICAN GOVERNOR
16 1715
LEGEND:
INDICATES GOVERMENT FURNISHED EQIPTMENT
INDICATED NEW WORK FROM RELOCATED ITEMS
INDICATES NEW WORK
INDICATES EXISTING EQUIPTMENT
REFERENCE:
ASSEMBLY (ALLIS-CHALMERS)
GOVERNOR INSTRUMENT PANELD2-570-333
R E
V
IS
E D P
E R A
M E
N D
M E
N T
NOTE 1
NOTE 1
EXISTING SWITCH AND GAUGE LAYOUT.
1. RELOCATE CONTROL SWITCHES AND GAUGES. ALIGN WITH
NOTE 1
EL: LH PANEL ASSEMBLY UNITS 2 & 4 (MK 801)
CBA
AB
19 20
4029 30
WIRING DUCT
OIL HEAD RESTORING CONDUIT
24 23
CL
CL
CL
CONDUIT
PMG LEADS
PMG LEADS CONDUIT
EL 288.5
PRESS TANK
PRESS LINE AT
TO PUMP PILOT
& (4) PANELS 19"X36"
CENTER PANEL 22"X36"
REMOVABLE PANELS
OPENING FOR
INTO GEN SWBD
CROSS-WIRING
END ONLY-FOR
OPENING IN OPP
C
21-26
INSTRUMENTS
TUBING TO
THERMOMETER
1/2" FACE OF FLANGES
CONDUIT BOX
INTO GOVERNOR
CROSS-WIRING
OPENING FOR
DC
AC
PRESS TO OPEN
10" OIL HEAD1'-4" 1'-4"
PRESS TO CLOSE
10" OIL HEAD
PANEL
INSTRUMENT
SWINGING
THIS END ONLY
28"X46 1/2"
CABINET DOOR (2)
(4) IN REAR SIDE
(2) IN FAR END
19"X36"
REMOVABLE PANELS
31 31 31
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
D A
T E
A P
P R
®of Engineers
US Army Corps of Engineers
US Army Corps
IS
S
U E D
A T
E
W A
L L
A W
A L L
A
W A
S H
IN
G T
O N
WALLA WALLA DISTRICT
c p w w o r k p w n w p d m s
M D
P
E D
V
X X d g n
D E S
E
D A
E
P
L O
T T
E D
C O
L U
M B
IA
R
IV
E R
M C
N A
R Y L
O C
K A
N D D
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
W A
L L
A W
A L L
A D
IS
T R
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
P O
R T
L A
N D
O R
E G
O N
P O
W E
R H
O U
S E E
X C
IT
E R
S
VOLUME 3
W E
F
R
G O
V E
R N
O R
S P
O W
E R
H O
U S
E C
O N
T R
O L S U
P G
R A
D E
M D
P .5
E
D
V
X X .d
ED501
IG
IT
A L G
O V A
C T
U A
T O
R C
A B D
E T
A
IL
S
U -1
O
D D U
N
IT
S
D
W
IL
L
IA
1.
THRUST BEARING OIL TEMPERATURE INDICATOR
GENERATOR BRAKE CONTROL SWITCH
CABINET LIGHT SWITCH
PRESSURE ISOLATING VALVE HANDWHEEL - AT REAR
DUPLEX AIR BRAKE PRESSURE GAUGE
GOVERNOR OIL-PRESSURE GAUGE
NOT USED
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
21.
22.
23.
13.
14.
15.
16.
17.
18.
19.
20.
26.
27.
28.
29.
30.
31.
33.
34.
35.
36.
24.
25.
32.
TACHOMETER INDICATOR
BLADE POSITION INDICATOR
BLANK COVER PLATE
TRANSFER VALVE POSITION INDICATOR
SPEED-DROOP INDICATOR
GATE LIMIT-GATE POSITION INDICATOR
SPEED ADJUSTMENT INDICATOR
SPEED-DROOP CONTROL KNOB
GATE LIMIT CONTROL KNOB
SPEED ADJUSTING CONTROL KNOB
TRANSFER VALVE CONTROL - MAIN TO AUXILIARY
MANUAL SHUTDOWN & RESET CONTROL
SCROLL CASE PRESSURE GAUGE
DRAFT TUBE PRESSURE GAUGE
GENERATOR UPPER GUIDE BEARING TEMPERATURE INDICATOR
THRUST BEARING TEMPERATURE INDICATOR
GENERATOR LOWER GUIDE BEARING TEMPERATURE INDICATOR
TURBINE BEARING OIL TEMPERATURE INDICATOR
TURBINE BEARING TEMPERATURE INDICATOR
GENERATOR COOLING WATER VALVE CONTROL SWITCH
TRANSFORMER COOLING WATER PUMP CONTROL SWITCH
TURBINE BEARING OIL PUMP CONTROL SWITCH
(RED HANDLE)
HEAD GATE EMERGENCY LOWERING CONTROL SWITCH
NOT USED
NOT USED
37.
38.
39.
PRESSURE ISOLATING VALVE POSITION INDICATOR - AT REAR
& EQUIPMENT MOUNTED IN BASE COMPARTMENTS
DEAD STOP & BREAKAWAY INDICATING LAMP AUXILIARIES
GOVERNOR BYPASS VALVE SHUTOFF SWITCH
41.
42.
40.
PIPE TERMINAL BLOCK
A.
B.
C.
D.
SCROLL CASE PRESSURE - TO GAUGE #9
SCROLL CASE BLEEDER - FROM GAUGE #19
DRAFT TUBE PRESSURE - TO GAUGE #20
SPARE
43.
44. GROUNDING PLATE
45.
47.
48.
46.
WIRING TERMINAL BLOCK (48 POLE)
MAPLE CLAMPING BLOCK - TO BE BORED IN FIELD
CONTACTORS FOR AUTOMATIC FREQUENCY CONTROL
CONDUIT OUTLET INSULATING COVER - TO BE BORED IN FIELD
56.
AUXILIARIES MOUNTED ON REAR OF CONTROL PANEL
NOT USED
THRUST BEARING HIGH PRESSURE OIL PUMP CONTROL SWITCH
NOT USED
TURBINE WATER FLOW RECORDER - AT REAR
NOT USED
GATE POSITION SELSYN TRANSMITTER
57.
58.
59.
60.
62.
63.
66.
OIL PRESSURE FAILURE RELAY SWITCH - 2 CONTACTS67.
68.
61.
64.
65.
SPEED ADJUST SELSYN TRANSMITTER
SYNCHRONIZING MOTOR WITH FRICTION DRIVE
SPEED ADJUSTMENT LIMIT SWITCH (2 POLE)
GATE LIMIT SELSYN TRANSMITTER
GATE LIMIT CONTROL MOTOR
COMPLETE SHUTDOWN & SPEED-NO-LOAD SOLENOIDS
GATE POSITION OPERATED SWITCH - 7 CONTACTS
GATE LIMIT OPERATED SWITCH - 2 CONTACTS
SPEED ADJUSTING MOTOR LIMIT SWITCH - RED HAND OPERATED
TACHOMETER RECTIFIER - RESISTOR PACK
GATE LIMIT SLIDEWIRE
R E
M O
V A
L
(3D CAM CONTROLLER)
5 75
12 13
17 18
D
D
MTD ON FRONT OF ACTUATOR:
INDICATORS & CONTROLS
982271O
ACTUATOR ARRANGEMENT UNIT 13
ACTUATOR ARRANGEMENT UNITS 5-7-9-11
982271 sh. 17
REFERENCES:
GREEN INDICATING LIGHT
RED INDICATING LIGHT
SYMBOLS:
SCALE: NTS SCALE: NTS
SCALE: NTS
NO 1
NO 2
45 45
P .K
E L L E
R
S T
E V
E N R
M
IL
E S P .E
NOT USED
GOV OIL PUMP INDICATING LIGHTS
S
G R
E G
O R
Y
NOTES:1
EXISTING SWITCH AND GAUGE LAYOUT.
1. RELOCATE CONTROL SWITCHES AND GAUGES. ALIGN WITH
NOTE 1
NOTE 1
EXISTING ITEMS TO BE RELOCATED
EXISTING ITEMS TO REMAIN
EXISTING ITEMS TO BE DISCONNECTED & REMOVED
LEGEND:
R E
V
IS
E D P
E R A
M E
N D
M E
N T
REAR OF ACTUATOR CONTROL PANEL
ARRANGEMENT OF AUXILIARIES ON
DETAIL: ACTUATOR CONTROL PANEL, SIDE
DETAIL: ACTUATOR CONTROL PANEL, FRONT
B C
WIRING DUCT
21 26
OIL HEAD RESTORING CONDUIT
CL
A C
A
27 4129 30
CL
1'-4"1'-4"
CL
CONDUIT
PMG LEADSCONDUIT
PMG LEADS
10" OIL HEAD PRESSURE TO OPEN
PRESS TO CLOSE
10" OIL HEAD
AC
DC
AT PRESS TANK
PRESSURE LINE
TO PUMP PILOT
PANEL
INSTRUMENT
SWINGING
EL 288.5
B
21-26
INSTRUMENTS
TUBING TO
THERMOMETER
46 46 46
1/2" FACE OF FLANGES
INTO GEN SWBD
CROSS-WIRING
END ONLY-FOR
OPENING IN OPP
CONDUIT BOX
INTO GOVERNOR
CROSS-WIRING
OPENING FOR
THIS END ONLY
28"X46 1/2"
CABINET DOOR (2)
(4) IN REAR SIDE
(2) IN FAR END
19"X36"
REMOVABLE PANELS
PRESSURE
RELAY VALVEDISCHARGE
RELAY VALVE
31 31 31
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
D A
T E
A P
P R
®of Engineers
US Army Corps of Engineers
US Army Corps
IS
S
U E D
A T
E
W A
L L
A W
A L L
A
W A
S H
IN
G T
O N
WALLA WALLA DISTRICT
c p w w o r k p w n w p d m s
M D
P
E D
V
X X d g n
D E S
E
D A
E
P
L O
T T
E D
C O
L U
M B
IA
R
IV
E R
M C
N A
R Y L
O C
K A
N D D
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
W A
L L
A W
A L L
A D
IS
T R
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
P O
R T
L A
N D
O R
E G
O N
P O
W E
R H
O U
S E E
X C
IT
This is the start of the file's text. The full file is on GovTribe.